Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW8090119_APPROVED PLANS_20090216 (2)
STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 001> l 1 0% DOC TYPE ❑ CURRENT PERMIT lil APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2D00%02lto YYYYMMDD LINTY OF BRUN _--SLICK r, VICINITY MAP (Not to Scale) OWNER CALABASH WASTEWATER COLLECTION SYSTEM E JERKY PIERCE BRUNSWICK COUNTY PO BOX 249 BUILDING G 20 REFERENDUM DRIVE BOLIVIA, NC 28422 PHONE (910)-253-2659 FAX (910)-253-4304 DESIGNER G. ERIC WILLIAMS, PE HDR ENGINEERING INC. OF THE CAROLINAS 1780-2 CHANDLERS LANE SUNSET BEACH, NC 28468 PHONE (910)-575-8800 FAX (910)-575-8801 CA 0 r ICK NUMBER DATE BY 1 12/2008 GEW I REGULATORY SUBMITTAL 4 a N 0 s 0 m APPROVAL STATUS ❑ YES ❑ NO ❑ N/A $ ❑ YES ❑ NO ❑ N/A ( ❑ YES ❑ NO ❑ N/A 3 g LOCATION MAP (Not to Scale) XPANSION TYPE OF WORK: THE WORK INCLUDES CONSTRUCTION OF APPROXIMATELY 58,000 LINEAR FEET OF 8" GRAVITY SEWER, 6" FORCEMAIN, 1 t1/2 TO 4" LOW PRESSURE SEWERS, MANHOLES, GRINDER PUMPS AND OTHER APPURTENANCES. THE PROJECT ALSO INCLUDES 2 NEW REGIONAL PUMPING STATIONS AND MODIFICATIONS TO ONE EXISTING PUMPING STATION. THIS WORK IS BEING PERFORMED IN ACCORDANCE WITH THE BRUNSWICK COUNTY CALABASH WASTEWATER COLLECTIONT SYSTEM EXPANSION PROJECT. DATE: 12/2008 SUBMITTAL: REGULATORY z O O p� U , W E-+ W H O 0 Coo Q W a O U W U U U z z w x � Q a O APPROVED NORTH CAR i,WA MENTAL MAN, ENT NM?AL DIVISION OF WATER QUAD F�b�ua. y I L, JAN 1 3 2009 CIVIL STRUCTURAL ELECTRICAL "ENGINEER'S CERTIFICATION OF COMPLIANCE WITH BRUNSWICK COUNTY SPECIFICATIONS AND DETAILS" I hereby certify that the plans, details, and associated project specifications comply with the latest version, as of this date, of TECH: ROBERTBLANTON Brunswick County's Standard Specifications and Standard Details per standard engineering practice. Furthermore, I confirm m understanding that reviews and approvals b Brunswick Count personnel do not imply that Brunswick Count personnel DES: G. ERIc WILLIAMS, PE Y g PP Y YP PY Y have reviewed and are in agreement with every portion of the plans and specifications that I have submitted. I understand that C1 JACK MILLER, PE — Brunswick County reviews and approvals are meant to ensure that the overall plans are in general compliance with County objectives. I understand that it is my full responsibility to ensure that plans and specifications are in full compliance with PROJECT NO. applicable County, State, Federal, and other municipal requirements. Additionally, I understand that the County will not 68249 assume operation, maintenance, or ownership of constructed facilities that do not meet County requirements and the County rrnay refuse to issue permits at facilities that the County deems are non -compliant with County Specifications. I also confirm SHEET NO. my understanding that County Inspections are for the sole use of the County and I certify that I will not use, or direct others to use, County inspections for State compliance purposes or any other purpose." 1 ($_OUNbARY TRAIL r c \\\ a ,n 0 2 \ 4 I 5 I „ , 0 F� % \ 1 7 c? F ( 1 S , t � 0 , 1 5 t „ / F \� 9 r G G / T .9 G S' r � 1 W r 1 C 107 , CO ,V t t p { l > 1 R Z � \ 1 P � y - , - rIr r' .'C A f F. Y O � 156 A 6 7 8 N INDEX OF DRAWINGS SHEET NO. ALIGNMENT SHEET NAME OOG-01 - KEY PLAN/INDEX OF DRAWINGS -'�""--- OOG-02 - GENERAL ABBREVIATIONS OOG-03 - GENERAL SYMBOLS AND LEGEND OOG-04 - ELECTRICAL ABBREVIATIONS, SYMBOLS AND NOTES OOG-05 - INSTRUMENTATION LEGEND OOG-06 - PROJECT SPECIFIC ABBREVIATIONS GENERAL PROJECT NOTES OOC-01 - STANDARD SEWER DETAILS OOC-02 - STANDARD SEWER DETAILS OOC-03 - STANDARD DETAILS OOC-04 - STANDARD CIVIL DETAILS OOC-05 - EROSION CONTROL DETAILS OOC-06 - EROSION CONTROL DETAILS - "e---- "' OOC-07 - STANDARD DETAILS 01C-101 Al-G, Ai -LP PLAN AND PROFILE STA 0+00 TO STA 7+62 STA 0+00 TO STA 4+00 01C-102 Al -LP PLAN AND PROFILE STA 4+00 TO STA 15+00 01C-103 Al -LP PLAN AND PROFILE STA 15+00 TO STA 23+97 r--' � 01C-104 B1-G PLAN AND PROFILE STA 0+00 TO STA 11+00 01C-105 B1-G PLAN AND PROFILE STA 11+00 TO STA 16+98 01C-106 61-LP PLAN AND PROFILE STA 0+00 TO STA 10+00 �- 01C-107 61-1-P, B1.1-LP PLAN AND PROFILE STA 10+00 TO 12+96 STA 0+00 TO STA 4+79 01C-108 B1.2-LP PLAN AND PROFILE STA 0+00 TO STA 11+00 01C-109 61.2-LP PLAN AND PROFILE STA 11+00 TO STA 22+00 01C-110 B1.2-LP PLAN AND PROFILE STA 22+00 TO STA 33+00 01C-111 81.2-LP PLAN AND PROFILE STA 33+00 TO STA 42+60 01C-112 C1-G PLAN AND PROFILE STA 0+00 TO STA 3+88 01C-113 D1-G PLAN AND PROFILE STA 2+00 TO STA 13+00 01C-114 D1-G PLAN AND PROFILE STA 13+00 TO STA 24+38 01C-115 D1-LP PLAN AND PROFILE STA 0+00 TO STA 8+50 01C-116 D1-LP PLAN AND PROFILE STA 8+50 TO STA 14+08 01C-117 D1.1-LP PLAN AND PROFILE STA 0+00 TO STA 10+50 01C-118 D1.1-LP PLAN AND PROFILE STA 10+50 TO STA 19+72 01C-119 D1.1.1-LP PLAN AND PROFILE STA 0+00 TO STA 7+62 01C-120 D1.2-LP PLAN AND PROFILE STA 0+00 TO STA 9+13 01C-121 D1.3-LP PLAN AND PROFILE STA 0+00 TO STA 11+95 01C-122 D1.4-LP PLAN AND PROFILE STA 0+00 TO STA 11+14 01C-123 D1.5-LP PLAN AND PROFILE STA 0+00 TO STA 10+00 i� r 01C- 124 D1.5.1- LP D1.9- LP PLAN AND PROFILE STA 0+00 TO STA 2+ 20 STA 0+00 TO STA 0+67 / 1. ! 01 1 C 25 D1.6 LP D1.8 LP PLAN AND PR FI 0 LE S TA O+ 00 TO STA 5t80 STA 0+00 TO STA 1+40 t d1 8., 01C-126 D1.7-LP PLAN AND PROFILE STA 0+00 TO STA 10+30 01C-127 D2-G PLAN AND PROFILE STA 0+00 TO STA 11+00 01C-128 D2-G PLAN AND PROFILE STA 11+00 TO STA 22+00 01C-129 D2-G PLAN AND PROFILE STA 22+00 TO STA 30+82 01C-130 D3-G, D3.1-G PLAN AND PROFILE STA 0+00 TO STA 7+85 STA 0+00 TO STA 1+91 -%"t 01C-131 D4-G PLAN AND PROFILE STA 0+00 TO STA 11+59 01C-132 D4-LP PLAN AND PROFILE STA 0+00 TO STA 5+07 D4.1-G, D4.1-LP PLAN AND PROFILE STA 0+00 TO STA 2+50 STA 0+00 TO STA 3+16 'P '', 01C-134 D5-G PLAN AND PROFILE STA 0+00 TO STA 5+50 O�•. >� \ 4j1 � �.,' 01C-135 D5-G PLAN AND PROFILE STA 5+50 TO STA 16+15 01C-136 OS -LP PLAN AND PROFILE STA 0+00 TO STA 11+50 01C-137 D5-LP, D5.5-LP PLAN AND PROFILE STA 11+50 TO STA 16+15 STA 0+00 TO STA 6+38 01C-138 D5.1-G, D5.1-1-P PLAN AND PROFILE STA 0+00 TO STA 3+24 STA 0+00 TO STA 1+87 F. v 01 C 139 D5.2-G D5.3 LP PLAN AND PROFILE STA 0+00 T0 STA 1 +76 STA 0+00 TO STA 5+77 , 01C 1,0 D5.2-LP, D5.4-LP PLAN AND PROFILE STA 0+00 TO STA 1+55 STA 0+00 TO STA 5+00 01C-141 El-G PLAN AND PROFILE STA 1+92 TO STA 11+50 9- \ 01C-142 Ei-G PLAN AND PROFILE STA 11+50 TO STA 22+50 �.y,;%%`� 01C-143 E1-G PLAN AND PROFILE STA 22+50 TO STA 27+55 01C-144 E1-LP PLAN AND PROFILE STA 0+00 TO STA 10+46 01C-145 E1.1-1-P, E1.2-LP PLAN AND PROFILE STA 0+00 TO STA 5+50 STA 0+00 TO STA 1+35 01C-146 E1.3-1-P, E1.4-LP PLAN AND PROFILE STA 0+00 TO STA 3+26 STA 0+00 TO STA 5+18 ,- ----- --� C1C-14' E2-G PLAN AND PROFILE STA 0+00 TO STA 4+27 .� _t f 01C-148 E3- G PLAN AND PROFILE STA 0+00 TO STA 10+25 01C-149 E3-LP PLAN AND PROFILE STA 0+00 TO STA 4+13 STA 0+00 TO STA 3+80 01C-150 E3.1-LP, E4-G PLAN AND PROFILE STA 0+00 TO STA 3+06 STA 0+00 TO STA 7+42 ' 01C-151 E5-G PLAN AND PROFILE STA 0+00 TO STA 11+00 CR—n of nnl nk,n nonru r cTe 4 1 nn Tn rTn nn ne UZt U BEACH DRIVE Y. k J D E PUMP STATION ELECTRICAL SITE PLAN > s r v y v.. r 1. I >7 - q 1 � G — �`•� / Z V 02E 102 BEACH DR IVE IVE PUMP STATION SINGLE LINE DIAGRAMS AND GROUNDING PLAN i d I C LP, q � AY POINT.ET 02E-103 - BEACH DRIVE PUMP STATION ELECTRICAL DETAILS ?� CN'. j 's 1Ji 02Y-101 - BEACH DRIVE PUMP STATION PROCESS AND INSTRUMENTATION DIAGRAM y - \ \, \, \,_ y <<� 01Cw BEACH` b' RIVE I ° __✓� t _ �.:'_ I _ j'' 02Y_102 _ BEACH DRIVE PUMP STATION PUMP CONTROL PANEL LAYOUT L -_. T1 02Y 103 _ BEACH DRIVE PUMP STATION PUMP CONTROL PANEL ELEMENTARY DIAGRAMS c^ \ 4 128 PUMP ,STATION m i 02Y-104 BEACH DRIVE PUMP STATION PUMP CONTROL PANEL ELEMENTARY DIAGRAMS DRAWING SERIES 02� i� �.- % 02Y-105 - BEACH DRIVE PUMP STATION RTU PANEL LAYOUT M ILL. r\LU V I I r\. UMNI\LI I, F L 'C \-� OtttJJl pa; iJ / C F 0 0 9 Q _ HDR Engineering, Inc. of the Carolinas 1 12/08 s ISSUE DATE U 7780-2 Chandlers Lane I Sunset Beach, NC 28648 FOR APPROVAL DESCRIPTION PROJECT NUMBER 008176-68249-018 02Y-106 - BEACH DRIVE PUMP STATION RTU PANEL ELEMENTARY DIAGRAMS i Z i. ltmif I � 02Y-107 - BEACH DRIVE PUMP STATION INSTRUMENTATION DETAILS I �U) ! t 03D-101 - WILSON AVENUE PUMP STATION SITE PLAN 03D-102 - WILSON AVENUE PUMP STATION SECTIONS AND DETAILS 03E-101 - WILSON AVENUE PUMP STATION ELECTRICAL SITE PLAN 03E-102 _ WILSON AVENUE PUMP STATION SINGLE LINE DIAGRAMS AND GROUNDING PLAN 03E-103 WILSON AVENUE PUMP STATION ELECTRICAL DETAILS 03Y-101 _ WILSON AVENUE PUMP STATION PROCESS AND INSTRUMENTATION DIAGRAM 03Y-102 WILSON AVENUE PUMP STATION PUMP CONTROL PANEL LAYOUT 03Y-103 - WILSON AVENUE PUMP STATION PUMP CONTROL PANEL ELEMENTARY DIAGRAMS 03Y-104 — WILSON AVENUE PUMP STATION PUMP CONTROL PANEL ELEMENTARY DIAGRAMS 03Y-105 — WILSON AVENUE PUMP STATION RTU PANEL LAYOUT 03Y-106 — WILSON AVENUE PUMP STATION RTU PANEL ELEMENTARY DIAGRAMS 03Y-107 — WILSON AVENUE PUMP STATION INSTRUMENTATION DETAILS 04D-101 — DOWNTOWN PUMP STATION UPGRADE SITE PLAN 04E DOWNTOWN PUMP STATION UPGRADE ELECTRICAL SITE PLAN -f�� ' 04E-102 — DOWNTOWN PUMP STATION UPGRADE SINGLE LINE DIAGRAM AND GROUNDING PLAN � /)o , ,��\, BRUNSWICK,,COUNTY KEY PLAN .;�r PUBLIC 1'�1TiL�(j�TIES INDEX OF DRAWINGS 9 CALABASH, lVASrtEWATER COLLECTION lYSTESHEET NNI4'EXPANSION - �i�"��\''"'a 0 1" 2" FILENAME OOG-01.dwg RUNSWICK COUNTY NORTH CAROLINA SCALE NO SCALE OOG'01 D C U 1 I 2 I 3 I 4 I 5 I 6 ( 7 I 8 A/C AIR CONDITIONING CLR CLEAR F&B FACE & BYPASS I INSTRUMENTATION (DWG DISCIPLINE) N NORTH, NEUTRAL R&R REMOVE AND REPLACE TOB TOP OF BOLT, TOP OF BANK, A/E ARCHITECT/ENGINEER CMH COMMUNICATION MANHOLE F TO F FACE TO FACE ID INSIDE DIAMETER, INTERIOR DIMENSION NA NOT APPLICABLE R&S REMOVE AND SALVAGE TOP OF BEAM A ARCHITECTURAL (DWG DISCIPLINE), AMP CMU CONCRETE MASONRY UNIT FAB FABRICATE IE INVERT ELEVATION NAT NATURAL R RADIUS, REGISTER, RISER TOC TOP OF CURB, TOP OF CONCRETE AB ANCHOR BOLT CO CLEAN OUT, CONCRETE OPENING FB FLOOR BEAM IF INSIDE FACE NC NORMALLY CLOSED RA RETURN AIR TOD TOP OF DUCT ABC AGGREGATE BASE COURSE COL COLUMN FBD FIBERBOARD IH INTAKE HOOD NEG NEGATIVE RB RESILIENT BASE, ROCK BERM TOF TOP OF FOOTING ABAN ABANDON COM COMMON FBG FIBERGLASS IMP IMPACT NF NEAR FACE, NON —FUSED RCPT RECEPTACLE TOG TOP OF GRATING AC ALTERNATING CURRENT COMB COMBINATION FBM BOARD FOOT MEASURE IN INCH NIC NOT IN CONTRACT RD ROOF DRAIN TOL TOLERANCE, TOP OF LEDGER ACK ACKNOWLEDGE COMM COMMUNICATION FBO FURNISHED BY OWNER INC INCLUDE,INCANDESCENT NO NORMALLY OPEN, NUMBER REC RECESS TOM TOP OF MASONRY ACIP ACOUSTIC CEILING PANEL, COMP COMPOSITION, COMPRESSIBLE, FC FLUSHING CONNECTION INF INFLUENT NOM NOMINAL RECD RECEIVED TOP TOP OF PLATE ASPHALTIC CONCRETE PAVEMENT COMPOSITE FCA FLANGED COUPLING ADAPTER INSTR INSTRUMENTATION NIPS NOMINAL PIPE SIZE RECT RECTANGULAR TOPO TOPOGRAPHY ACST ACOUSTIC CONC CONCENTRIC, CONCRETE FD FLOOR DRAIN INSUL INSULATION NPT NATIONAL PIPE THREAD RED REDUCER TOS TOP OF SLAB, TOP OF STEEL AD ADDENDUM, AREA DRAIN CONN CONNECTION FDC FLEXIBLE DUCT CONNECTION INT INTERIOR, INTERSECTION NS NEAR SIDE REF REFERENCE TOW TOP OF WALL ADDL ADDITIONAL CONST CONSTRUCTION FDTN FOUNDATION INTIR INTERMEDIATE, INTERIOR NTS NOT TO SCALE REINF REINFORCING TP TOILET PARTITION, TELEPHONE POLE, ADH ADHESIVE CONT CONTINUOUS FOR FEEDER INV INVERT NWL NORMAL WATER LEVEL REM REMOVE TOE PLATE, TRAP PRIMER ADJ ADJUSTABLE, ADJACENT ' COOR COORDINATE FE FLANGED END IPS IRON PIPE SIZE REQD REQUIRED TPD TOILET PAPER DISPENSER AF AMP FRAME, AMP FUSE CORR CORROSIVE, CORRUGATED FEC FIRE EXTINGUISHER CABINET IPT INTERNAL PIPE THREAD RESIL RESILIENT TPG TOPPING AFF ABOVE FINISH FLOOR CP CHECKER PLATE, CONTROL POINT FES FLARED END SECTION IR INSIDE RADIUS 0 TO 0 OUT —TO —OUT RET RETAINING, RETURN TR TRANSOM AFG ABOVE FINISH GRADE CPLG COUPLING FEXT FIRE EXTINGUISHER IRR IRRIGATION CIA OUTSIDE AIR, OVERALL REV REVISION, REVERSE TRANS TRANSITION AGGR AGGREGATE CRL CORROSION RESISTANT LINING FF FAR FACE, FACTORY FINISH, FLAT FACE ISO ISOMETRIC OC ON CENTER RF RESILIENT FLOORING TRD TRENCH DRAIN Al AREA INLET CSC COMPRESSION SLEEVE COUPLING FG FINISHED GRADE OCPD OVER CURRENT PROTECTION DEVICE RFG ROOFING TYP TYPICAL AIC - AMPS INTERRUPTING CAPACITY CSK COUNTERSINK FIG FIGURE JB JUNCTION BOX OD OUTSIDE DIAMETER RFL REFLECTED, REFLECTOR ALIG ALIGNMENT CSS CLINIC SERVICE SINK FH FIRE HYDRANT JCT JUNCTION QED OPEN END DUCT RGH ROUGH U URINAL ALUM ALUMINUM CT CERAMIC TILE FIN FINISH JF JOINT FILLER OF OUTSIDE FACE, OFFICE FURNISHING RGS RIGID GALVANIZED STEEL UG UNDERGROUND ALT ALTERNATE, ALTITUDE CTR CENTER FJT FLUSH JOINT JST JOIST OG ORIGINAL GROUND RGS—PVC PVC COATED RGS UN ULTIMATE AM ACOUSTICAL MATERIAL CTRL CONTROL FL FLOW, FLOW LINE JT JOINT OH OVERHEAD RH RELIEF HOOD, RIGHT HAND, UNO UNFINISHED AMB AMBIENT CVT CULVERT FLEX FLEXIBLE OPNG OPENING RELATIVE HUMIDITY UNO UNLESS NOTED OTHERWISE ANC ANCHOR CU COPPER, CUBIC FLG FLANGE K KIP OPP OPPOSITE RL REQUIRED LAP UTIL UTILITY AP ACCESS PANEL CW CLOCKWISE FLOR FLUORESCENT OPT OPTIONAL RLFA RELIEF AIR APRX APPROXIMATE CY CUBIC YARD FLR FLOOR KB KNEE BRACE OR OUTSIDE RADIUS RND ROUND APVD APPROVED FLS FLASHING, FLUSH KCMIL ' THOUSAND CIRCULAR MILS ORD OVERFLOW ROOF DRAIN RNG RUNNING V VENT, VELOCITY, VOLT ARCH ARCHITECTURAL FN FENCE KD KO KNOCK DOWN KNOCK OUT ORIG ORIGINAL RO ROUGH OPENING VA VOLT AMPERE ASSY ASSEMBLY d PENNY (NAIL MEASURE) FO FINISHED OPENING OVFL OVERFLOW ROW RIGHT OF WAY VAC VACUUM AT AMP TRIP D DEEP, DIFFUSER FOB FENCE FLAT ON BOTTOM KSI KIPS PER SQUARE INCH OVHG OVERHANG RPM REVOLUTIONS PER MINUTE VAR VARNISH, VARIABLE, ATC ACOUSTICAL TILE CEILING D6 DUCT BANK, DECIBEL, DRY BULB FOC FACE OF CONCRETE, FACE OF CURB OZ OUNCE RR RAILROAD VOLT AMPERES REACTIVE ATM ATMOSPHERE DBA DEFORMED BAR ANCHOR FOF FACE OF FINISH L ANGLE, LENGTH, LAVATORY RSP ROCK SLOPE PROTECTION VB VAPOR BARRIER, VINYL BASE, AUTO AUTOMATIC DBL DOUBLE FOM FACE OF MASONRY LAD LADDER RT RIGHT VALVE BOX AUX AUXILIARY DC DIRECT CURRENT FOS FACE OF STUDS LAM LAMINATE P PAINT, PROCESS (DWG DISCIPLINE) RVT RESILIENT VINYL TILE VC VERTICAL CURVE AVE AVENUE DEG DEGREE FOT FLAT ON TOP LATL LATERAL PA PUBLIC ADDRESS RY READY VCT VINYL COMPOSITION TILE, AVG AVERAGE DEG C DEGREE CENTIGRADE FPT FEMALE PIPE THREAD LB LAG BOLT, POUND PAR PARALLEL, PARAPET VERTICAL CENTERLINE AWG AMERICAN WIRE GAGE DEG F DEGREE FAHRENHEIT FIR FRAME LCTB LIQUID CHALK AND TACK BOARD PB PANIC BAR, PULL BOX VEL VELOCITY AWT ACOUSTICAL WALL TILE DEMO DEMOLITION FRP FIBERGLASS REINFORCED PLASTIC LOG LANDING PBD PARTICLE BOARD S SOUTH, SINK, STRUCTURAL VENT VENTILATION B/B BACK TO BACK DEP DEPRESSED FRTM FIRE RETARDANT TREATED MATERIAL LDR LEADER PC POINT OF CURVE, PIECE, PRECAST (DWG DISCIPLINE) VERT VERTICAL BAL BALANCE DEPT DEPARTMENT FS FLOOR SINK, FAR SIDE LE LIFTING EYE PCC POINT OF COMPOUND CURVATURE SA SUPPLY AIR VG VERTICAL GRAIN BBD BULLETIN BOARD DET DETAIL FT FEET, FOOT LF LINEAR FOOT PCF POUNDS PER CUBIC FOOT SAMU SOUND ABSORBING MASONRY UNIT VIF VERIFY IN FIELD BC BASE CABINET, BOTTOM CHORD, DI DROP INLET, DUCTILE IRON FTG FOOTING, FITTING LG LONG PCT PERCENT SAN SANITARY VIN VINYL BOLT CENTER, BOLT CIRCLE DIA DIAMETER FUR FURRED, FURRING LH LEFT HAND PE PLAIN END SB SPLASH BLOCK VS VERSES, VAPOR SEAL BD BOARD DIAG DIAGONAL, DIAGRAM FURN FURNITURE, FURNISH LIN LINEAR PED PEDESTAL SC SOLID CORE VOL VOLUME BE BOTH ENDS, BELL END DIFF DIFFERENTIAL, DIFFERENCE FUT FUTURE LIQ LIQUID PEN PENETRATION SCH SCHEDULE VPC VERTICAL POINT OF CURVATURE BF BOTH FACES, BOTTOM FACE, DIM DIMENSION FV FACE VELOCITY LLH LONG LEG HORIZONTAL PERF PERFORATED SCHEM SCHEMATIC VPI VERTICAL POINT OF INTERSECTION BLIND FLANGE, BOARD FEET DISCH DISCHARGE FW FIELD WELD, FIRE WALL LLV LONG LEG VERTICAL PERM PERMANENT SCN SCREEN VPT VERTICAL POINT OF TANGENCY BITUM BITUMINOUS DIST DISTANCE, DISTRIBUTION FWD FORWARD LMLU LIQUID MARKER LECTURE UNIT PERP PERPENDICULAR SCP STEEL CASING PIPE VTR VENT THROUGH ROOF BKG BACKING DIV DIVISION FWE FURNISHED WITH EQUIPMENT LNG LONGITUDINAL PF POWER FACTOR SE STEEL/ALUMINUM EDGE VWC VINYL WALL COVERING BL BASE LINE DL DEAD LOAD FXTR FIXTURE LOC LOCATION PFMU PREFACED MASONRY UNIT SEC SECONDARY, SECONDS BLDG BUILDING DMJ DOUBLE MECHANICAL JOINT G GRILLE, GROUND, LP LOW POINT PH PHASE SECT SECTION W/ WITH BLK BLOCK DMPF DAMP PROOFING GENERAL (DWG DISCIPLINE ) LPS LOW PRESSURE SODIUM PI POINT OF INTERSECTION SEP SEPARATE W/0 WITHOUT BLKG BLOCKING DN DO DISSOLVED OXYGEN, DITTO WN GA GAGE (METAL THICKNESS) LR LT LONG RADIUS LEFT PKG PACKAGE SF SQUARE FOOT W WATT, WEST, WIDE, WINDOW, WIRE, BM BENCHMARK, BEAM DP DEPTH GAL GALLON LTD LIMITED PL PLATE, PROPERTY LINE SG SHEET GLASS, SEALANT GROOVE WI LANCE BEAM BOC BACK OF CURB DPDT DOUBLE POLE, DOUBLE THROW GALV GALVANIZED LTG LIGHTING PLAT PLASTER SH SHOWER WB WOOD BASE BOD BOTTOM OF DUCT DPST DOUBLE POLE, SINGLE THROW GB GRAB BAR, GRADE BREAK LTL LINTEL PLAT PLATFORM SHT SHEET WC WATER CLOSET, WATER COLUMN BOG BOTTOM OF GRILLE DS DOWN SPOUT GC GROOVED COUPLING LTNG LIGHTNING PLBG PLUMBING SHTG SHEATHING WD WOOD, WIDTH BOL BOTTOM OF LOUVER DT DOUBLE TEE, DRIP TRAP ASSEMBLY GO GUARD LV LOW VOLTAGEWF PLF POUNDS PER LINEAR FOOT SIL SILENCE WIDE FOUNTAIN BOP BOTTOM OF PIPE DUP DUPLICATE GEN GENERAL LVR LOUVER PNEU PNEUMATIC SIM SIMILAR WG WIRE GLASS, WATER GAGE BOR BOTTOM OF REGISTER DWG DRAWING GFCI GROUND FAULT CIRCUIT INTERRUPTER LW LIGHTWEIGHT POL POLISH SL SLOPE WH WALL HYDRANT, WEEP HOLE BOT BOTTOM DWL DOWEL GFMU GROUND FACE MASONRY UNIT LWC LIGHTWEIGHT CONCRETE PPS POSITIVE, POSITION SLID SLOTTED WI WROUGHT IRON BOU BOTTOM OF UNIT DWR DRAWER GG GUTTER GRADE LWL LOW WATER LEVEL PP POLYPROPYLENE, POWER POLE SLV SLEEVE WL WATER LEVEL BP BASE PLATE GJ GROOVED JOINT PRC POINT OF REVERSE CURVATURE SMLS SEAMLESS WLD WELDED BRG BEARING GL GLASS PREF PREFINISHED SOG SLAB ON GRADE WM WIRE MESH BRGP BEARING PLATE EAST, ELECTRICAL (DWG DISCIPLINE) GLB GLASS BLOCK M MECHANICAL (DWG DISCIPLINE) PREFAB PREFABRICATED SP SOUNDPROOF, STANDPIPE WP WATERPROOF, WORKING POINT BRKT BRACKET E EACH, EXHAUST AIR GND GROUND MA MIXED AIR PRELIM PRELIMINARY SPA SPACING WTHP WEATHERPROOF BS BOTH SIDES EA ELECTRICAL CONTRACTOR GP GUY POLE MACH MACHINED PREP PREPARE SPEC SPECIFICATION WS WATERSTOP, WATER SURFACE BTU BRITISH THERMAL UNIT EC ECCENTRIC GR GRADE MAINT MAINTENANCE PRIES PRESSURE SPLY SUPPLY WSCT WAINSCOT BTU BETWEEN ECC EQUIPMENT DRAIN GRTG GRATING MAN MANUAL PRI PRIMARY SPST SINGLE POLE SINGLE THROW WT WEIGHT, WATER TIGHT BTWLD BUTT WELD ED ELECTRICAL DUCT BANK GSB GYPSUM SHEATHING BOARD MATL MATERIAL PROP PROPERTY SPT SET POINT WWF WELDED WIRE FABRIC BU BELL UP, BUILT UP EDB GT GREASE TRAP MAX MAXIMUM PROT PROTECTION SQ SQUARE BUR BUILT—UP ROOFING EE EACH END GVL GRAVEL M6 MACHINE BOLT PS PIPE SUPPORT SR SHORT RADIUS BW BOTH WAYS EF EACH FACE EFFLUENT, EFFICIENCY GWB GYPSUM WALLBOARD MBR MEMBER PSF POUNDS PER SQUARE FOOT SS SERVICE SINK XP EXPLOSION PROOF BYP BYPASS EFF ELECTRICAL HANDHOLE GYP GYPSUM HARDBOARD MC MECHANICAL CONTRACTOR, PSI POUNDS PER SQUARE INCH SST STAINLESS STEEL XS EXTRA STRONG EFF EXTERIOR INSULATION & MECHANICAL COUPLING PSIA POUNDS PER SQUARE INCH ABSOLUTE ST STREET XXS DOUBLE EXTRA STRONG C TO C CENTER TO CENTER EIFS SYSTEM MCB METAL CORNER BEAD PSIG POUNDS PER SQUARE INCH GAGE STA STATION XSECT CROSS SECTION C&G CURB & GUTTER FINISH H HIGH MCJ MASONRY CONTROL JOINT PST PRESTRESSED STD STANDARD C CHANNEL SHAPE, CENTIGRADE, EJ EXPANSION JOINT HB HOSE BIB MDMJ MODIFIED DOUBLE MECHANICAL JOINT PT POINT, POINT OF TANGENCY STIF STIFFENER CONDUIT, CIVIL (DRAWING DISCIPLINE) EL ELBOW, ELEVATION HBD HARDBOARD MECH MECHANICAL PTN PARTITION STIR STIRRUP YH YARD HYDRANT CAB CABINET ELEC ELECTRICAL HC HANDICAPPED, HOLLOW CORE, MED MEDIUM PVC POLYVINYL CHLORIDE STL STEEL YS YIELD STRENGTH CAP CAPACITY EMBD EMBEDDED HORIZONTAL CURVE MFR MANUFACTURER PVMT PAVEMENT STOR STORAGE CAT' CATALOG EMER EMERGENCY HC HORIZONTAL CENTERLINE MH MANHOLE, METAL HALIDE PWD PLYWOOD STIR STRUCTURAL, STRAIGHT GENERAL NOTES: CAV CAVITY EMH ELECTRICAL MANHOLE HDR HEADER MIN MINIMUM PWJ PLYWOOD WEB JOIST SUB SUBSTITUTE CIB CATCH BASIN ENCL ENCLOSURE HDW HARDWARE MIR MIRROR PZ PIEZOMETER SUC SUCTION 1. THESE ABBREVIATIONS APPLY TO THE ENTIRE SET CCB CONCRETE BLOCK ENGR ENGINEER HEX HEXAGONAL MISC MISCELLANEOUS SUSP SUSPENDED OF CONTRACT DRAWINGS. CCW COUNTER CLOCKWISE ENTR ENTRANCE HGR HANGER MJ MECHANICAL JOINT SY SQUARE YARD CDF CONTROLLED DENSITY FILL EOP EDGE OF PAVEMENT HH HANDHOLE MLO MAIN LUGS ONLY SYM SYMBOL 2. LISTING OF ABBREVIATIONS DOES NOT IMPLY ALL CE CONCRETE EDGE EQ EQUAL HID HIGH INTENSITY DISCHARGE MMB MEMBRANE Q RATE OF FLOW SYMM SYMMETRICAL ABBREVIATIONS ARE USED IN THE CONTRACT CER CERAMIC EQUIP EQUIPMENT HM HOLLOW METAL MO MASONRY OPENING QT QUARRY TILE SYN SYNTHETIC DRAWINGS. CF (FOOT) CUBIC FEET FOOT EQUIV EQUIVALENT HORIZ HORIZONTAL MOD MODULAR, MODIFY QTR QUARTER SYS SYSTEM CFL COUNTER FLASHING ES EACH SIDE, EQUAL SPACE, HP HIGH POINT, HORSEPOWER MON MONUMENT QU QUANTITY 3. ABBREVIATIONS SHOWN ON THIS SHEET INCLUDE CHFR CHAMFER EMERGENCY SHOWER HPC HORIZONTAL POINT OF CURVATURE MPT MALE PIPE THREAD QUAL QUALITY T&B TOP AND BOTTOM VARIATIONS OF THE WORD. FOR EXAMPLE, "MOD' CHBD CHALKBOARD ESEW EMERGENCY SHOWER AND EYE WASH HPS HIGH PRESSURE SODIUM MRGWB MOISTURE RESISTANT T&G TONGUE AND GROOVE MAY MEAN MODIFY OR MODIFICATION; "INC" MAY CHO CHORD EST ESTIMATE HPT HORIZONTAL POINT OF TANGENCY GYPSUM WALLBOARD T TILE, TREAD MEAN INCLUDED OR INCLUDING; "REINF° MAY CHH COMMUNICATION HANDHOLE EW EACH WAY, EMERGENCY HR HOSE REEL, HOUR MS MOP SINK TA TOILET ACCESSORY, TEMPERED AIR MEAN EITHER REINFORCE OR REINFORCING. CI CURB INLET EYE/FACE WASH HS HEADED STUD, HIGH STRENGTH MSL MEAN SEA LEVEL TAN TANGENT CIP CAST —IN —PLACE EWC ELECTRIC WATER COOLER HSS HOLLOW STRUCTURAL SHAPE MT MOUNT TBM TEMPORARY BENCHMARK 4. SCREENING OR SHADING OF WORK IS USED TO CIPB CONCRETE INTERLOCKING PAVER EWEF EACH WAY, EACH FACE HT HEIGHT MU MASONRY UNIT TCE TEMPORARY CONSTRUCTION EASEMENT INDICATE EXISTING COMPONENTS OR TO BALLAST EWTB EACH WAY, TOP AND BOTTOM HTG HEATING MULL MULLION TEF TROWELED EPDXY FLOORING DE—EMPHASIZE PROPOSED IMPROVEMENTS TO CIRC CIRCULATION, CIRCULAR EXC EXCAVATION HV HIGH VOLTAGE MV MEDIUM VOLTAGE TEMP TEMPORARY, TEMPERATURE HIGHLIGHT SELECTED TRADE WORK. REFER TO CJ CONSTRUCTION JOINT EXH EXHAUST HVAC HEATING, VENTILATION & MW MONITORING WELL THD THREAD CONTEXT OF EACH SHEET FOR USAGE. CKT CIRCUIT EXST EXISTING AIR CONDITIONING THK THICK CIL CENTERLINE, CLASS, CLOSE EXP EXPANSION, EXPOSED HWD HARDWOOD THRESH THRESHOLD 5. SEE P&ID LEGEND SHEET FOR PROJECT SPECIFIC CLG CEILING EXT EXTERIOR, EXTERNAL, EXTENSION HWL HIGH WATER LEVEL THRU THROUGH EQUIPMENT SYMBOLS, EQUIPMENT ABBREVIATIONS CLJ CONTROL JOINT HYD HYDRAULIC TKBD TACK BOARD AND PIPING SYSTEM ABBREVIATIONS. H Y PER N CLKG CAULKING fal HDR Engineering, Inc. of the Carolinas 1780-2 Chandlers Lane I Sunset Beach, NC 28648 PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY M. SHULTZ, PE 1 10/2008 IREGULATORY SUBMITTAL ISSUE I DATE I DESCRIPTION PROJECT NUMBER 0081 76-68249-018 L sEv I 24U olLel09 FA�� WII��P BRUNSWI PUBLIC. CALAB► H COLLECTIONply 'qRH BRUNSWICK COUNTY OUNTY GENERAL ABBREVIATIONS Ifs IES WATER EXPANSION SHEET 0 1" 2" FILENAME DOG-02.dwg NORTH CAROLINA SCALE NO SCALE OOG—O! D C B 0 2 I 3 I 4 I 5 I 6 I 7 I 8 GENERAL SYMBOLS EXISTING PROPOSED EXISTING PROPOSED TBM (TAG NUMBER) (ELEVATION)TEMPORARY BENCH MARK PL - - - - - - - PL L J R/W - - R/W STRUCTURES/BUILDING COMPONENTS rn ROADWAY - - - -986 0- 986.0, CONTOUR 0 � TREES, SHRUBS, OR BUSHES TREE LINE (CLUSTER OR SHRUBS) -X X- 0.5 0 0.5% - SLOPE N 1099.04 E 798.63 COORDINATE --- FIRE HYDRANT SF H VALVE ® (PLAN) COMBINATION AIR/VACUUM RELEASE VALVE SIZE IN INCHES -� Q4 (PROFILE) ►TD--►TDB O PRECAST MANHOLE/VAULT C----� SCP n AU AERIAL UTILITY ------ FO ------ FIBER OPTIC ------ G ------ GAS LINE ----- SS ------ SANITARY SEWER LINE MATERIALS IN PLAN/SECTION ACOUSTICAL CEILING TILE (SECTION) PROPERTY LINE ASPHALT (PLAN OR SMALL SCALE SECTION) RIGHT-OF-WAY ® ASPHALT (LARGE SCALE SECTION) DOT CONTROLLED ACCESS BATT INSULATION (SECTION) RIGHT-OF-WAY PERMANENT EASEMENT BRICK MASONRY (PLAN/SECTION) CHECKERED PLATE (PLAN) TEMPORARY EASEMENT CONCRETE (PLAN/SECTION) GUY WIRE CONCRETE MASONRY (PLAN/SECTION) FENCE - ® DEMOLITION (PLAN/SECTION) DITCH EARTH (SECTION) SECONDARY ROAD, DRIVEWAY, PRIVATE ENTRANCE, ETC. FILTER POINT MAT (PLAN) SILT FENCE ® FINISHED WOOD (SECTION) TEMPORARY SEDIMENT TRAP GLU-LAM LUMBER (SECTION) TEMPORARY DIVERSION OOOQOO GRANULAR FILL (SECTION) (GRADE TO DRAIN) GRATING (SECTION) CHECK DAM GRATING (PLAN) TEMPORARY STREAM CROSSING GROUT (SECTION) ROCK PIPE INLET PROTECTION GYPSUM BOARD (SECTION) TEMPORARY DROP METAL (SECTION) INLET PROTECTION ORIENTED STRAND BOARD (SECTION) PARTICLE BOARD (SECTION) PLYWOOD (LARGE SCALE SECTION) Wi oN f?tt{Y L. JR A- OWNER NAME ELECTRICAL LINE 61C1f, It W/ -'Ofq `d 1PFt02, � PARCEL I.D. PLYWOOD (SMALL SCALE SECTION) E 10 3513135 72 PIN # TELEPHONE PRECAST CONCRETE (PLAN/SECTION) ------ T------- UNDERGROUND TYPICAL PROPERTY OWNER INFORMATION RIGID INSULATION (SECTION) - - - W - - - WATER LINE - - - LPS - - LPS LOW PRESSURE SEWER - - -FM- - - SANITARY SEWER FORCE MAIN GRAVITY SANITARY SEWER --O GRAVITY SEWER SERVICE LATERAL WITH CLEAN OUT —0 LOW PRESSURE SERVICE CONNECTION 0 FLUSHING CONNECTION fal HDR Engineering, Inc. of the Carolinas 1780-2 Chandlers Lane I Sunset Beach, NC 28648 BOO RIPRAP (PLAN/SECTION) SAND (SECTION) SOD (SECTION) WEEP JOINT MORTAR PROTECTION SYSTEM (SECTION) ® WOOD - CONTINUOUS (SECTION) WOOD BLOCKING (SECTION) PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY M. SHULTZ, PE 1 10/08 REGULATORY SUBMITTAL ISSUE I DATE DESCRIPTION PROJECT NUMBER 008176-68249-01 81 AI CARp4EA �or<essior � 12434 V m F�h�n s D110106 WI1��P� I *•s�wwsssn'•ss• GENERAL SYMBOLOGY N TARGET ELEVATION ARROW INDIC DIRECTION Of PLAN PLAN NORTH 1/4" = 1'-0" SECTION LETTER FLAG INDICATES DIRECTION OF SECTION CUT-----. X CXX * SHEET WHERE SECTION VIEW IS LOCATED SECTION CUT MARKER SECTION LETTER >ECTION X 3/8" = 1'-0" XXX * SHEET WHERE SECTION VIEW IS FIRST CUT DETAIL NUMBER XXX * SHEET WHERE DETAIL IS LOCATED DETAIL MARKER DETAIL NUMBER DETAIL- # 3" = 1'-0" XXX REPRESENTATIVE DRAWING WHERE DETAIL WAS CALLED OUT ELEVATION IDENTIFICATION ELEVATION LETTER X 3" = 1'-0" XXX * SHEET WHERE POINT OF VIEW MARKER CAN BE FOUND * IF PLAN AND SECTION, OR DETAIL CALL -OUT AND DETAIL ARE SHOWN ON SAME SHEET, SHEET NUMBER IS REPLACED BY A LINE (-). XXXXXXXXX DETAIL MARKER DETAIL MARKER FOR REFERENCING DETAILS BOUND IN SPECIFICATIONS OR SEPARATE VOLUME. ELEVATION LETTER ARROW INDICATES X POINT OF VIEW XX * SHEET WHERE ELEVATION IS LOCATED SINGLE ELEVATION OR PHOTO MARKER ELEVATION LETTER ARROW INDICATES POINT OF VIEW ELEVATION X X X INDICATES SHEET WHERE A-11 ELEVATION IS LOCATED MULTIPLE ELEVATION OR PHOTO MARKER KEY NOTE NUMBER # KEY NOTE DESIGNATION BRUNSWICK-COUNTY e PUBLIC IJTI� RyIES CALAB4Si, , , A,S-'1NATER COLLECTION"° YSaTL!"EM.-EXPANSION BRUNSWICK COUNTY NORTH CAROLINA ARCHITECTURAL ROOM NAME XX-XX ROOM NUMBER XX DOOR NUMBER OCOLUMN GRID LINE �X WALL TYPE OX WINDOW TYPE LOUVER OG GLASS TYPE 0 ACCESSORY, FURNITURE & MISCELLANEOUS EQUIPMENT IDENTIFIER IDENTIFICATION SYMBOLOGY PIPING: FIGURE 36-PLE EXAMPLE LINE SIZE 36" SERVICE PLANT EFFLUENT EQUIPMENT IDENTIFICATION ALTERNATE 1 NPWP2023 FIGURE YY XAMPL SERVICE TYYI INDICATES NON ABBREVIATION I POTABLE WATER EQUIPMENT 11 I INDICATES PUMP ABBREVIATION BUILDING OR STRUCTURE BUILDING 20 NUMBER EQUIPMENT PUMP 23 NUMBER ALTERNATE 2 FIGURE NPWP-23 EXAMPLE SERVICE INDICATES NON ABBREVIATION POTABLE WATER EQUIPMENT INDICATES PUMP ABBREVIATION EQUIPMENT NUMBER PUMP 23 GENERAL NOTES: 1. THIS IS A STANDARD SHEET SHOWING COMMON SYMBOLOGY. ALL SYMBOLS ARE NOT NECESSARILY USED ON THIS PROJECT. 2. SCREENING OR SHADING OF WORK IS USED TO INDICATE EXISTING COMPONENTS OR TO DE-EMPHASIZE PROPOSED IMPROVEMENTS TO HIGHLIGHT SELECTED TRADE WORK. REFER TO CONTEXT OF EACH SHEET FOR USAGE. GENERAL SYMBOLS AND LEGEND 0 1" 2" FILENAME OOG-03.dwg SHEET SCALE NO SCALE OOG-03 r C B 1 I 2 I 3 I 4 I 5 I 6 I 7 I 8 O\ X 100AF OR )80AT LOW - VOLTAGE CIRCUIT BREAKER (CB). OF POLES AS SHOWN. KVA NON -MOTOR LOAD WITH DESIGN KVA, KW, OR AMP O NORMALLY OPEN LEVEL SWITCH, CLOSE ON RISING LEVEL X X Iz DOUBLE-FACED CEILING OR WALL -MOUNTED CR FIRE ALARM CONTROL RELAY 0J20A 3P O RATINGS AND NO. WHEN SPECIFIC TYPE IS REQUIRED, X INDICATES Y Y EXIT LIGHT; DIRECTIONAL ARROWS (IF REQUIRED) FS FIRE ALARM CONTACT, FLOW SWITCH 3P �-- AS INDICATED ON PLANS TYPE. TYPES: NORMALLY CLOSED LEVEL SWITCH,037 OPEN ON RISING LEVEL X X �" (3Y L/0IY SINGLE -FACED CEILING OR WALL -MOUNTED EXIT LIGHT; DIRECTIONAL ARROWS (IF REQUIRED) AS TS FIRE ALARM CONTACT, TAMPER SWITCH MCCB -MOLDED CASE CPT CONTROL POWER TRANSFORMER (CPT) O INDICATED ON PLANS p5 ICCB - INSULATED CASE NORMALLY OPEN PRESSURE SWITCH, X FIRE ALARM CONTACT, PRESSURE SWITCH LVP - LOW - VOLTAGE POWER CLOSE ON INCREASING PRESSURE Y AREA OR ROADWAY LIGHT - POLE -MOUNTED MCP - MOTOR CIRCUIT PROTECTOR (RATING PER CONNECTED LOAD) VOLTAGE TRANSFORMER (VT OR PT) or NORMALLY CLOSED PRESSURE SWITCH, OPEN ON INCREASING PRESSURE LIGHTING FIXTURE SUBSCRIPTS: O AND SMOKE AND DUCT DETECTOR X - INDICATES FIXTURE TYPE PER LIGHTING X X CB SEPARATELY MOUNTED CIRCUIT BREAKER; SEE FIXTURE SCHEDULE SUBSCRIPT: ELECTRICAL ONE - LINE DIAGRAM OR CURRENT TRANSFORMER (CT) NORMALLY OPEN LIMIT SWITCH, Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD I - IONIZATION TYPE SCHEDULE FOR DESCRIPTION CLOSE ON REACHING LIMIT z - INDICATES CONTROLLING SWITCH (IF REQUIRED) P - PHOTOELECTRIC TYPE GFP GROUND FAULT PROTECTION Of a NORMALLY CLOSED LIMIT SWITCH, Y �X TOGGLE SWITCH X HEAT DETECTOR 8UTILITY WATT-HOUR METER PER UTILITY OPEN ON REACHING LIMIT SUBSCRIPTS: SUBSCRIPT: 52 MEDIUM -VOLTAGE CIRCUIT BREAKER REQUIREMENTS X - INDICATES TYPE NONE - SINGLE POLE R/C - RATE COMPENSATION o----fl FIELD WIRING EXTERNAL TO CONTROL PANEL 3 - THREE-WAY R/F - COMBINATION RATE OF RISE AND -IQ}- FUSE, SIZE, AND NUMBER OF FUSES AS NOTED rDMPI DIGITAL METERING PACKAGE /� - -__ X _ INTERLOCK; X INDICATES TYPE 4 - FOUR-WAY HP - TOGGLE SWITCH, HORSEPOWER RATED K - KEY SWITCH R - RATE OFIREDETEMP F - FIXED RATING, FUSE SIZE, �v/ TE MANUAL MOTOR STARTER WITH THERMAL ELEMENT FUSED CUTOUT, CURRENT RTM RUN TIME METER TYPES: - � ALARM BELL AND NUMBER OF POLES AS NOTED P - PILOT LIGHT Lam" -�- FUSIBLE SWITCH, CURRENT RATING, FUSE SIZE, E - ELECTRICAL M - MECHANICAL L - LIGHTED HANDLE Y - INDICATES CONTROLLING SWITCH (IF REQUIRED) X ALARM HORN AND QUANTITY AS NOTED OFF K - KEY GROUND HAND I AUTO �- NON -FUSED SWITCH, CURRENT RATING, AND _ �% XOO 3 POSITION SELECTOR SWITCH, MAINTAINED CONTACTS; SPECIAL-PURPOSE RECEPTACLE AS DEFINED ON PLANS L:_P ALARM FLASHING LIGHT NUMBER OF POLES AS NOTED I _ _ UNLESS OTHERWISE NOTED, 2-POSITION SIMILAR ALARM BELL AND FLASHING LIGHT ^ DISCONNECT OR DRAWOUT CONNECTION LIGHTNING ARRESTER I COX V ® PLUG-IN RECEPTACLE STRIP, QUANTITY AND SPACING OF COMBINATION UNIT RECEPTACLES AS NOTED OR SPECIFIED ALARM HORN AND FLASHING LIGHT A c� & A c� ® MAGNETIC MOTOR STARTER AND SEPARATELY MOUNTED COMBINATION MAGNETIC SPD LOW VOLTAGE SURGE PROTECTIVE DEVICE O O NORMALLY OPEN PUSHBUTTON, MOMENTARY CONTACT UNLESS OTHERWISE NOTED N TELECOMMUNICATIONS OUTLET JUNCTION BOX L_� COMBINATION UNIT SUBSCRIPT: B B MOTOR STARTER o I o NORMALLY CLOSED PUSHBUTTON, MOMENTARY CONTACT UNLESS OTHERWISE NOTED X � QUAD -DUPLEX RECEPTACLE, TWO NEMA 5-20R NONE - GENERAL ALARM MOTOR CONTROLLER AND ELECTRICAL CONNECTION - - INDICATING LIGHT, X INDICATES LENS COLOR y UNDER COMMON COVER PLATE DEVICE F - FIRE ALARM DEVICE D v & D o SEPARATELY MOUNTED MOTOR CONTROLLER WITH t:@Y idY DUPLEX RECEPTACLE, NEMA 5-20R SHORT CIRCUIT PROTECTION AND DISCONNECT I OR OR - NO ELECTRICAL CONNECTION Y�� PUSH TO TEST INDICATING LIGHT, X INDICATES MOTOR STARTER AND CONTROLLER SUBSCRIPTS: It _O LENS COLOR X I-eY SIMPLEX RECEPTACLE, NEMA 5-20R A - MAGNETIC STARTER NEMA SIZE A SV OR SOLENOID VALVE LENS COLORS: SUBSCRIPTS: B - STARTER TYPE I IIII R - RED Y -YELLOW G - GREEN W - WHITE X - INDICATES TYPE NONE - FULL VOLTAGE NON -REVERSING (FVNR) B - BLUE A - AMBER GFCI - GROUND FAULT CIRCUIT INTERRUPTER FVR - FULL VOLTAGE REVERSING 2S - TWO SPEED X OY CONTROL/RELAY COIL; X INDICATES TYPE, a TRANSFORMER Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD RVAT - REDUCED VOLTAGE AUTO TRANSFORMER Y INDICATES LOOP NO. WHEN USED TYPES: O CONDUIT TURNING UP C -CONTROL DIAGRAM OR CONTROLS CR -CONTROL RELAY SS SELECTOR SWITCH SCHEDULE NUMBER (IF REQUIRED) DP - DEFINITE PURPOSE RELAY CONDUIT TURNING DOWN LC - LIGHTING CONTACTOR PB PUSHBUTTON D - CONTROLLER TYPE VFD - VARIABLE FREQUENCY DRIVE M - MOTOR STARTER PC - PHOTO CELL IC INSTRUMENTATION CONTROL DEVICE / HOME RUN TO PANEL, 2 #12, 1 #12G IN SS - SOLID STATE TC - TIME CLOCK 3/4"C UNLESS OTHERWISE NOTED TR - TIMING RELAY rvh SEPARATELY MOUNTED COMBINATION MOTOR CONTROL PANEL INTEGRAL OR PROVIDED WITH iinl STARTER OR CONTROLLER; SEE ELECTRICAL --��-- NORMALLY OPEN CONTACT (N.O.) ASSOCIATED EQUIPMENT CIRCUIT RUN BETWEEN DEVICES EXPOSED IN ONE - LINE DIAGRAM OR SCHEDULE FOR NON -ARCHITECTURALLY FINISHED AREAS; DESCRIPTION -- NORMALLY CLOSED CONTACT (N.C.) �I CONTROL PANEL WITH DISCONNECT SWITCH INTEGRAL OR CONCEALED IN ARCHITECTURALLY FINISHED PROVIDED WITH ASSOCIATED EQUIPMENT AREAS. CONDUIT AND CONDUCTOR SIZES SHALL THERMAL OVERLOAD ELEMENT NORMALLY OPEN TIME DELAY RELAY CONTACT QJ JUNCTION OR PULL BOX BETHE CIRCT. SAME AS THE HOMERUN FOR THE WITH TIME DELAY ON CLOSING AFTER COIL IS OL ENERGIZED PANELBOARD (250V TO 60OV) - - - - - - CONDUIT RUN BETWEEN DEVICES CONCEALED IN THERMAL OVERLOAD RELAY CONTACT NORMALLY CLOSED TIME DELAY RELAY CONTACT NON -ARCHITECTURALLY FINISHED AREAS OR WITH TIME DELAY ON OPENING AFTER COIL IS UNDER FLOOR SLAB. CONDUIT AND CONDUCTOR DISCONNECT OR SAFETY SWITCH, 30A, 3P, ENERGIZED ® PANELBOARD (LESS THAN 250V) SIZES SHALL BE THE SAME AS THE HOMERUN FOR THE CIRCUIT. u NON -FUSED UNLESS OTHERWISE NOTED NORMALLY OPEN TIME DELAY RELAY CONTACT WITH TIME DELAY ON OPENING AFTER COIL IS Q ELECTRICAL EQUIPMENT ENCLOSURE: SWITCHBOARD, CIRCUIT HASH MARKS (WHEN INDICATED); LONG, DE -ENERGIZED MOTOR CONTROL CENTER, CONTROL PANEL, OR OTHER SHORT, SINGLE DOT, AND DOUBLE DOT EQUIPMENT AS INDICATED REPRESENT PHASE, NEUTRAL, EQUIPMENT 7 1/2 OR HP MOTOR WITH DESIGN HORSEPOWER NORMALLY CLOSED TIME DELAY RELAY CONTACT WITH TIME DELAY ON CLOSING AFTER COIL IS GROUND, AND ISOLATED EQUIPMENT GROUND, (WHEN INDICATED) DE -ENERGIZED PC PHOTOCELL RESPECTIVELY. �j12 IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED. O NORMALLY OPEN TEMPERATURE SWITCH; CLOSE ON RISING TEMPERATURE X � CEILING/PENDANT-MOUNTED LUMINAIRE - HID, -� CIRCUIT CONTINUATION 7..t y COMPACT FLUORESCENT, OR INCANDESCENT CONDUIT STUBBED OUT AND CAPPED O GENERATOR NORMALLY CLOSED TEMPERATURE SWITCH; OPEN ON RISING TEMPERATURE X z Y WALL -MOUNTED LUMINAIRE - HID, COMPACT FLUORESCENT, OR INCANDESCENT XXX CONDUIT TAG OR CIRCUIT NUMBER - WIRE AND CONDUIT SIZE AS SPECIFIED IN CIRCUIT TRANSFER SWITCH, CURRENT RATING, AND NUMBER OF POLES AS NOTED �o NORMALLY OPEN FLOW SWITCH; ©Q X y CEILING/PENDANT-MOUNTED FLUORESCENT SCHEDULE ON THE SHEETS MATS CL05E ON INCREASING FLOW FIXTURE ATS - AUTOMATIC MTS - MANUAL X � z WALL -MOUNTED FLUORESCENT FIXTURE - - GROUND CABLE NORMALLY CLOSED FLOW SWITCH; y OPEN ON INCREASING FLOW ® X CEILING/PENDANT-MOUNTED FLUORESCENT O GROUND ROD GENERAL NOTES: tM�J ry-T-Y, TRANSFORMER Y FIXTURE NORMAL/EMERGENCY FAA FIRE ALARM ANNUNCIATOR 1. THIS IS A STANDARD ELECTRICAL SYMBOLOGY SHEET. NOT ALL SYMBOLS MAY BE USED ON THIS PROJECT. X WALL -MOUNTED FLUORESCENT FIXTURE A 3-PHASE, 3-WIRE DELTA CONNECTION Y NORMAL/EMERGENCY FACP FIRE ALARM CONTROL PANEL 2. SCREENING OR SHADING OF WORK IS USED TO INDICATE EXISTING 1e, 3-PHASE, 4-WIRE GROUNDED WYE ,t X � EMERGENCY LIGHT FIXTURE, 2 ATTACHED HEADS COMPONENTS OR TO DE-EMPHASIZE PROPOSED IMPROVEMENTS CONNECTION AS SHOWN FIRE ALARM MANUAL PULL STATION TO HIGHLIGHT SELECTED SHEET FOR USAGE. TRADE WORK. REFER TO CONTEXT OF EACH 1°'00 SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, TX Y EMERGENCY LIGHT, REMOTE MOUNTED HEAD 3. SEE P&ID LEGEND SHEET FOR PROJECT -SPECIFIC EQUIPMENT PHASE, NUMBER OF WIRES WHEN INDICATED SYMBOLS, EQUIPMENT ABBREVIATIONS, AND PIPING SYSTEM ABBREVIATIONS. Issal HDR Engineering, Inc. of the Carolinas 1780-2 Chandlers Lane I Sunset Beach, NC 28648 PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER B.FOX, PE CHECKED BY B. FOX, PE 1 10/08 REGULATORY SUBMITTAL ISSUE DATE DESCRIPTION 1 PROJECT NUMBER 008176-68249-01 f SE L F Nit" �pl10lp8 6• A'61f ••NNNaea••••••• BRUNSWI K;°COUNTY -.. PUBLIC. YfILIES CALABA, ST TER COLLECTION''' yy§jE, I EXPANSION y jjk'a\1rys.4�4 BRUNSWICK COUNTY NORTH CAF ELECTRICAL ABBREVIATIONS, SYMBOLS AND NOTES O 1" 2,, FILENAME OOG-04.dwg JA SCALE NO SCALE OOG-04 1C C I- v 1 I 2 I 3 I 4 I 5 I 6 I 7 I 8 O 20A OR O 100AF > ) LOW - VOLTAGE CIRCUIT BREAKER (CB). SHOWN. 100 KVA NON -MOTOR LOAD WITH DESIGN KVA, KW, OR AMP 0 NORMALLY OPEN LEVEL SWITCH, X "- X DOUBLE-FACED CEILING OR WALL -MOUNTED 80AT RATINGS AND NO. OF POLES AS CLOSE ON RISING LEVEL 2 Hz EXIT LIGHT; DIRECTIONAL ARROWS (IF REQUIRED) O' GROUND ROD 0 3P 0 3P WHEN SPECIFIC TYPE IS REQUIRED, X INDICATES TYPE. NORMALLY CLOSED LEVEL SWITCH,or Y Y AS INDICATED ON PLANS TYPES: OPEN ON RISING LEVEL X X ® rvyl SINGLE -FACED CEILING OR WALL -MOUNTED EXIT LIGHT; DIRECTIONAL ARROWS (IF REQUIRED) AS FAA FIRE ALARM ANNUNCIATOR """ CPT CONTROL POWER TRANSFORMER (CPT) Y Y MCCB - MOLDED CASE 1CCB - INSULATED CASE LOW - VOLTAGE POWER I I NORMALLY OPEN PRESSURE SWITCH, CLOSE ON INCREASING PRESSURE X INDICATED ON PLANS AREA OR ROADWAY LIGHT - POLE -MOUNTED FACP FIRE ALARM CONTROL PANEL LVP - MCP - MOTOR CIRCUIT PROTECTOR (RATING PER CONNECTED LOAD) -3 F VOLTAGE TRANSFORMER (VT OR PT) or NORMALLY CLOSED PRESSURE SWITCH, Y LIGHTING FIXTURE SUBSCRIPTS: ❑ FIRE ALARM MANUAL PULL STATION CB SEPARATELY MOUNTED CIRCUIT BREAKER; SEE OPEN ON INCREASING PRESSURE X - INDICATES FIXTURE TYPE PER LIGHTING FIXTURE SCHEDULE CR FIRE ALARM CONTROL RELAY ELECTRICAL ONE - LINE DIAGRAM OR SCHEDULE FOR DESCRIPTION CURRENT TRANSFORMER (CT) NORMALLY OPEN LIMIT SWITCH, CLOSE ON REACHING LIMIT Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD z - INDICATES CONTROLLING SWITCH (IF REQUIRED) FS FIRE ALARM CONTACT, FLOW SWITCH "'ttt GFP GROUND FAULT PROTECTION OV Q NORMALLY CLOSED LIMIT SWITCH, X $ X TOGGLE SWITCH TS FIRE ALARM CONTACT, TAMPER SWITCH WH UTILITY WATT-HOUR METER PER UTILITY REQUIREMENTS OPEN ON REACHING LIMIT SUBSCRIPTS: X - INDICATES TYPE PS FIRE ALARM CONTACT, PRESSURE SWITCH 52 MEDIUM - VOLTAGE CIRCUIT BREAKER . NONE - SINGLE POLE "{0}- FUSE, SIZE, AND NUMBER OF FUSES AS NOTED DMP DIGITAL METERING PACKAGE 0----0 FIELD WIRING EXTERNAL TO CONTROL PANEL 3 - THREE-WAY 4 - FOUR-WAY OX AND (J )X SMOKE AND DUCT DETECTOR — — X INTERLOCK; X INDICATES TYPE HP -TOGGLE SWITCH, HORSEPOWER RATED K - KEY SWITCH v -� FUSED RATING, FUSE SIZE, TE MANUAL MOTOR STARTER WITH THERMAL ELEMENT SUBSCRIPT: CUTOUT, CURRENT TYPES: - AND NUMBER OF POLES AS NOTED RTM RUN TIME METER P - PILOT LIGHT I - IONIZATION TYPE E - ELECTRICAL L - LIGHTED HANDLE P - PHOTOELECTRIC TYPE -�� FUSIBLE SWITCH, CURRENT RATING, FUSE SIZE, M - MECHANICAL Y - INDICATES CONTROLLING SWITCH (IF REQUIRED) (DX AND QUANTITY AS NOTED OFF K - KEY HEAT DETECTOR GROUND HAND j AUTO NON -FUSED SWITCH, CURRENT RATING, AND _ �� X00 3 POSITION SELECTOR SWITCH, MAINTAINED CONTACTS; SPECIAL-PURPOSE RECEPTACLE AS DEFINED ON PLANS SUBSCRIPT: NUMBER OF POLES AS NOTED b UNLESS OTHERWISE NOTED, 2-POSITION SIMILAR R/C - RATE COMPENSATION DISCONNECT OR DRAWOUT CONNECTION LIGHTNING ARRESTER _ _�_ OOX ® PLUG-IN RECEPTACLE STRIP, QUANTITY AND SPACING OF R/F - COMBINATION RATE OF RISE AND FIXED TEMP RECEPTACLES AS NOTED OR SPECIFIED R - RATE OF RISE A & A MAGNETIC MOTOR STARTER AND SEPARATELY MOUNTED COMBINATION MAGNETIC SPD LOW VOLTAGE SURGE PROTECTIVE DEVICE 0 0 NORMALLY OPEN PUSHBUTTON, MOMENTARY CONTACT UNLESS OTHERWISE NOTED N TELECOMMUNICATIONS OUTLET JUNCTION BOX X F - FIXED ALARM BELL B B MOTOR STARTER o I NORMALLY CLOSED PUSHBUTTON, MOMENTARY CONTACT UNLESS OTHERWISE NOTED X p® QUAD -DUPLEX RECEPTACLE, TWO NEMA 5-20R MOTOR CONTROLLER AND ELECTRICAL CONNECTION —X INDICATING LIGHT, X INDICATES LENS COLOR Y X UNDER COMMON COVER PLATE � ALARM HORN D & D o SEPARATELY MOUNTED MOTOR CONTROLLER WITH ��qo, v DUPLEX RECEPTACLE, NEMA 5-20R ALARM FLASHING LIGHT SHORT CIRCUIT PROTECTION AND DISCONNECT I -t- OR OR - NO ELECTRICAL CONNECTION X PUSH TEST INDICATING LIGHT, X INDICATES Y MOTOR STARTER AND CONTROLLER SUBSCRIPTS: I LENS COLOR X EB ALARM BELL AND FLASHING LIGHT Fe SIMPLEX RECEPTACLE, NEMA 5-20R COMBINATION UNIT A - MAGNETIC STARTER NEMA SIZE SV OR SOLENOID VALVE LENS OLORS: Y SUBSCRIPTS: X ALARM HORN AND FLASHING LIGHT B - STARTER TYPE R - R D Y -YELLOW G - GREEN W - WHITE X - INDICATES TYPE COMBINATION UNIT NONE - FULL VOLTAGE NON -REVERSING (FVNR) B - BLUE A - AMBER GFCY - ROUND CIRCUIT SUBSCRIPT: FVR - FULL VOLTAGE REVERSING 23 -TWO SPEED X CONTROL/RELAY COIL; X INDICATES TYPE, TRANSF RMER - INDICATES RCUITAULT FROMNPANELBTERD NONE - GENERAL ALARM RVAT - REDUCED VOLTAGE AUTO TRANSFORMER Y Y INDICATES LOOP NO. WHEN USED DEVICE TYPES: —Q CONDUIT TURNING UP F - FIRE ALARM DEVICE C - CONTROL DIAGRAM OR CONTROLS CR - CONTROL RELAY SS SELECTOR SWITCH SCHEDULE NUMBER (IF REQUIRED) DP - DEFINITE PURPOSE RELAY CONDUIT TURNING DOWN LC - LIGHTING CONTACTOR PB PUSHBI. TTON D - CONTROLLER TYPE M - MOTOR STARTER HOME RUN TO PANEL, 2 #12, 1 #12G IN VFD - VARIABLE FREQUENCY DRIVE PC - PHOTO CELL TC - TIME CLOCK IC-� ❑ INSTRUMENTATION/CONTROL DEVICE 3/4"C UNLESS OTHERWISE NOTED SS - SOLID STATE TR -TIMING RELAY SEPARATELY MOUNTED COMBINATION MOTOR L PANEL INTEGRAL OR PROVIDED WITH STARTER OR CONTROLLER; SEE ELECTRICAL -�F- NORMALLY OPEN CONTACT (N.O.) ASSOCIATED A SSOCI TED EQUIPMENT CIRCUIT RUN BETWEEN DEVICES EXPOSED IN ONE - LINE DIAGRAM OR SCHEDULE FOR NON -ARCHITECTURALLY FINISHED AREAS; DESCRIPTION- NORMALLY CLOSED CONTACT (N.C.) CONTR L PANEL WITH DISCONNECT SWITCH INTEGRAL OR CONCEALED IN ARCHITECTURALLY FINISHED PROVIDED WITH ASSOCIATED EQUIPMENT AREAS. CONDUIT AND CONDUCTOR SIZES SHALL THERMAL OVERLOAD ELEMENT NORMALLY OPEN TIME DELAY RELAY CONTACT JUNCTIONOR PULL BOX BETHE CIRCE. SAME AS THE HOMERUN FOR THE WITH TIME DELAY ON CLOSING AFTER COIL IS OL ENERGIZED PANELB ARD (250V TO 600V) -- - - - - CONDUIT RUN BETWEEN DEVICES CONCEALED IN THERMAL OVERLOAD RELAY CONTACT NORMALLY CLOSED TIME DELAY RELAY CONTACT NON -ARCHITECTURALLY FINISHED AREAS OR WITH TIME DELAY ON OPENING AFTER COIL IS UNDER FLOOR SLAB. CONDUIT AND CONDUCTOR DISCONNECT OR SAFETY SWITCH, 30A, 3P, ENERGIZED ® PANELB ARD LESS THAN 250V ( ) SIZES SHALL BE THE SAME AS THE HOMERUN FOR THE CIRCUIT. u u NON -FUSED UNLESS OTHERWISE NOTED NORMALLY OPEN TIME DELAY RELAY CONTACT WITH TIME DELAY ON OPENING AFTER COIL IS ELECTRI AL EQUIPMENT ENCLOSURE: SWITCHBOARD, CIRCUIT HASH MARKS (WHEN INDICATED); LONG, DE -ENERGIZED MOTOR CONTROL CENTER, CONTROL PANEL, OR OTHER HIIH SHORT, SINGLE DOT, AND DOUBLE DOT EQUIPM NT AS INDICATED REPRESENT PHASE, NEUTRAL, EQUIPMENT 7 1/2 OR HP MOTOR WITH DESIGN HORSEPOWER NORMALLY CLOSED TIME DELAY RELAY CONTACT WITH TIME DELAY ON CLOSING AFTER COIL IS GROUND, AND ISOLATED EQUIPMENT GROUND, (WHEN INDICATED) DE -ENERGIZED PC PHOTOCELL RESPECTIVELY. #12CAT IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED. O NORMALLY OPEN TEMPERATURE SWITCH; CLOSE ON RISING TEMPERATURE X � CEILING PENDANT -MOUNTED LUMINAIRE - HID, --� CIRCUIT CONTINUATION �..c Y COMPA T FLUORESCENT, OR INCANDESCENT CONDUIT STUBBED OUT AND CAPPED O GENERATOR NORMALLY CLOSED TEMPERATURE SWITCH; OPEN ON RISING TEMPERATURE X Y WALL- OUNTED LUMINAIRE - HID, COMPACT FLUORE CENT, OR INCANDESCENT XXX CONDUIT TAG OR CIRCUIT NUMBER - WIRE AND CONDUIT SIZE AS SPECIFIED IN CIRCUIT 0 TRANSFER SWITCH, CURRENT RATING, AND NUMBER OF POLES AS NOTED �0 NORMALLY OPEN FLOW SWITCH; ©Q Y X CEILING PENDANT -MOUNTED FLUORESCENT SCHEDULE ON THE SHEETS CLOSE ON INCREASING FLOW FIXTURE ATS ATS - AUTOMATIC MTS MANUAL 11:90 X WALL- OUNTED FLUORESCENT FIXTURE - - GROUND CABLE - NORMALLY CLOSED FLOW SWITCH; Y OPEN ON INCREASING FLOW ®X CEILING PENDANT -MOUNTED FLUORESCENT ------� DISCRETE SIGNAL GENERAL NOTES: Y FIXTURE NORMAL/EMERGENCY 1. THIS IS A STANDARD ELECTRICAL SYMBOLOGY SHEET. NOT ALL �Y�Y1 TRANSFORMER X WALL- OUNTED FLUORESCENT FIXTURE - - - - - - "' ANALOG SIGNAL SYMBOLS MAY BE USED ON THIS PROJECT: A 3-PHASE, 3-WIRE DELTA CONNECTION � Y NORMAL/EMERGENCY 2. SCREENING OR SHADING OF WORK IS USED TO INDICATE EXISTING Y� 3-PHASE, 4-WIRE GROUNDED WYE �X EMERGE,ICY LIGHT FIXTURE, 2 ATTACHED HEADS COMPONENTS OR TO DE-EMPHASIZE PROPOSED IMPROVEMENTS CONNECTION Y TO HIGHLIGHT SELECTED TRADE WORK. REFER TO CONTEXT OF EACH AS SHOWN SHEET FOR USAGE. aw SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, i X Y EMERGENCY LIGHT, REMOTE MOUNTED HEAD 3. SEE P&ID LEGEND SHEET FOR PROJECT -SPECIFIC EQUIPMENT PHASE, NUMBER OF WIRES WHEN INDICATED SYMBOLS, EQUIPMENT ABBREVIATIONS, AND PIPING SYSTEM ABBREVIATIONS. IMA. HDR Engineering, Inc. of the Carolinas 1780.2 Chandlers Lane I Sunset Beach, NC 28648 PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY M. SHULTZ, PE 1 10/08 REGULATORY SUBMITTAL ISSUEI DATE DESCRIPTION PROJECT NUMBER 008176-68249-01t sN' �. ° � � !' ° IIpI S wi��°`� BRUNS PUBJ CALAB I COLLECTION BRUNSWICK COUNTY M,OUNTY INSTRUMENTATION LEGEND `)Kt IES SfEWATER ;r EWEXPANSION SHEET 0 V, 2" FILENAME OOG-05.dwg NORTH CAROLINA I I SCALE I NO SCALE I OOG-05 C N 2 I EDIHI 3 I 4 I 5 I 6 I 7 I 8 PROJECT SPECIFIC ABBREVIATIONS GENERAL PROJECT NOTES 1. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY ASSOCIATED 17. ALL TIE-INS SHALL BE SCHEDULED AND COORDINATED WITH BRUNSWICK COUNTY WITH THE WORK UNDER THIS PROJECT AND FOR COMPLIANCE WITH ALL UTILITIES AT LEAST 24 HOURS PRIOR TO MAKING CONNECTION. ARV - AIR RELEASE VALVE MB - MAIL BOX FEDERAL, STATE, AND LOCAL HEALTH AND SAFETY LAWS, CODES, REGULATIONS, AND ORDINANCES INCLUDING BUT NOT LIMITED TO THOSE 18. SEE SPECIFICATION SECTION 02221 FOR BLASTING REQUIREMENTS. ASP - ASPHALT MH - MANHOLE CURRENTLY MANDATED BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA). 19. REMOVAL AND REPLACEMENT OR REPAIR OF EXISTING UTILITY SERVICES BCPU - BRUNSWICK COUNTY PUBLIC UTILITIES SHALL BE COORDINATED WITH APPROPRIATE UTILITY COMPANY. COST SHALL OHP - OVERHEAD POWER/TELEPHONE LINE 2. USE ADEQUATE SHORING METHODS TO ENSURE: BE BORNE BY THE CONTRACTOR. BFV - BUTTERFLY VALVE OHT - OVERHEAD TRANSMISSION LINE A. COMPLIANCE WITH OSHA REGULATIONS. 20. IT WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE B. PROTECTION OF EXISTING PAVEMENT AND ROAD SHOULDERS. WITH POWER AND TELEPHONE COMPANIES FOR RELOCATING OR STABILIZING ANY C. CONSTRUCTION ACTIVITIES ARE CONFINED TO RIGHTS -OF -WAY EXISTING POLES DISTURBED BY CONSTRUCTION. THIS WORK SHALL BE DONE AT BO - BLOW -OFF OR EASEMENTS AS INDICATED. NO ADDITIONAL COST TO THE OWNER. PED - PEDESTAL BS - BUSINESS SIGN 21. REMOVE AND REPLACE WITH EQUAL OR BETTER MATERIAL ALL EXISTING PAVEMENTS, 3. INSTALL GRAVITY SEWER, SEWER FORCE MAIN AND LOW PRESSURE SEWER DRIVEWAYS, GRAVEL ROADWAYS, PIPE CULVERTS, CULVERT HEADWALLS, FENCES, P/L - PROPERTY LINE AS INDICATED ON PLANS AND DO NOT DISTURB ANY AREA WITHIN 3' (FEET) BILLBOARDS, MAIL BOXES, AND MISCELLANEOUS ITEMS WHERE REQUIRED TO FROM THE EDGE OF PAVEMENT (UNLESS NOTED OTHERWISE). LIMITS OF COMPLETE THE CONSTRUCTION. CAN - CABLE TELEVISION PP - POWER POLE CONSTRUCTION SHALL BE CONFINED TO EXISTING NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) RIGHTS OF WAY OR EASEMENTS INDICATED. 22. TAKE APPROPRIATE ACTION TO ENSURE THAT ACCESS TO EXISTING RESIDENCES CB - CATCH BASIN AND PROPERTY IS NOT IMPAIRED DURING CONSTRUCTION. PROVIDE TEMPORARY RCP - REINFORCED CONCRETE PIPE DRIVEWAY ACCESS FOR ALL PROPERTY OWNERS ADJACENT TO CONSTRUCTION AREAS, IF REQUIRED DURING PERIODS WHEN CONSTRUCTION IN THE AREA IS CONC - CONCRETE 4. ACCESS TO THE PIPELINE RIGHT-OF-WAY SHALL BE ALONG EXISTING ROADS OR IN PROGRESS. RJ - RESTRAINED JOINT ALONG PERMANENT AND CONSTRUCTION EASEMENTS ONLY. IF ADDITIONAL AREAS CMP - CORRUGATED METAL PIPE ARE NEEDED FOR THE STORAGE OF EQUIPMENT OR SUPPLIES, MAKE ARRANGEMENTS FOR OBTAINING SUCH AREAS AND NOTIFY THE OWNER OF ALL SUCH ARRANGEMENTS 23. .WHEN A TEMPORARY DRIVEWAY CONNECTED TO NCDOT ROADWAY IS REQUIRED,. RS - ROAD SIGN OBTAIN ANY NECESSARY PERMITS FROM NCDOT. DIP - DUCTILE IRON PIPE R/W - RIGHT-OF-WAY 5. PIPE AND MATERIALS NEEDED FOR CONSTRUCTION WILL BE DELIVERED TO THE SITE DAILY, AS NEEDED. MATERIALS SHALL NOT BE STORED OR STRUNG ALONG 24. TESTING AND CLEANING: DR - DRIVE RPZ - REDUCED PRESSURE ZONE ROADWAY UNLESS PERMITTED BY NCDOT. A. MAKE PROVISIONS FOR TEST SECTIONS AND/OR OTHER FACILITIES REQUIRED FOR TESTING THE PIPELINE. SUCH FACILITIES WILL NOT BE SCP - STEEL CASING PIPE 6. GRAVITY SEWER, SEWER FORCE MAIN AND LOW PRESSURE SEWER TO BE PAID FOR SEPARATELY BUT SHALL BE INCIDENTAL TO THE UNIT PRICE EOP - EDGE OF PAVEMENT INSTAW T N 5 FEET OF EDGE OF RIGHT OF WAY UNLESS SHOWN BID FOR THE PIPE fal MDR Engineering, Inc. of the Carolinas FB - FLOWER BED FH - FIRE HYDRANT FM - FORCE MAIN FO - FIBER OPTIC CABLE GR - GRAVEL GV - GAS VALVE GW - GUY WIRE IE - INVERT ELEVATION LF - LINEAR FEET LP - LIGHT POLE LPS - LOW PRESSURE SEWER LL OR NOTED OTHERWISE. PARCEL LINES INCLUDING RIGHT-OF-WAY LINES B. LIMITED WATER WILL BE AVAILABLE FOR TESTING OF NEW SEWER FORCE SS - SANITARY SEWER ARE TAKEN FROM BRUNSWICK COUNTY GIS SYSTEM AND IN MANY CASES MAIN AND LOW PRESSURE SEWER. OBTAIN WATER FOR INITIAL FILLING DO NOT PERFECTLY ALIGN WITH THE SURVEYED RIGHT-OF-WAY AND TESTING FROM BRUNSWICK COUNTY PUBLIC UTILITIES. QUANTITY SST - STAINLESS STEEL MONUMENTS AND EXISTING PROPERTY CORNERS. CONTRACTOR IS TO USE AND TIME OF WATER DELIVERY WILL BE DETERMINED BY COUNTY STAFF. EXISTING RIGHT-OF-WAY MONUMENTS AND EXISTING PROPERTY CORNERS TO LOCATE THE RIGHT-OF-WAY TO PROPERLY INSTALL THE RESPECTIVE C. SEE SPECIFICATION SECTION 15060 FOR ADDITIONAL INFORMATION. STA - STATION UTILITY LINES AS INDICATED ABOVE. 7. PLACE SCREENINGS MINIMUM 1/4" THICK AND/OR SAND ON ALL 25. ALL HOLES, TRENCHES, AND OTHER HAZARDOUS AREAS SHALL BE ADEQUATELY PAVED ROADS PRIOR TO PLACEMENT OF EXCAVATED MATERIAL AND/OR BACKFILL PROTECTED BY BARRICADES, LIGHTS OR OTHER PROTECTIVE DEVICES. TEL - TELEPHONE ON NCDOT PAVEMENT. 26. REMOVAL OF EXCAVATED MATERIALS AND DAILY CLEANUP OPERATIONS SHALL BE TS&V - TAPPING SLEEVE AND VALVE PERFORMED IN COMPLIANCE WITH THE SPECIFICATIONS AND TO THE SATISFACTION 8. REPAIR/REPLACE ALL STATE MAINTAINED PAVEMENT DAMAGED BY OF THE OWNER/ENGINEER AND NCDOT. CONSTRUCTION ACTIVITIES TO SATISFACTION OF NCDOT. NO SEPARATE PAYMENT SHALL BE MADE FOR PAVEMENT REPAIR EXCEPT AS NOTED ON PLANS. 27• ALL ROCK, BRUSH, TIMBER, AND OTHER DEBRIS THAT ARE CLEARED FROM THE UGE - UNDERGROUND ELECTRICAL RIGHTS -OF -WAY SHALL BE REMOVED FROM THE PREMISES AND SHALL NOT BE 9. INSTALL TRACER WIRE ON ALL BURIED NON-METALILIC SEWER PLACED ON ADJOINING LANDS, EXCEPT WHERE ARRANGEMENTS FOR SUCH PIPING. INSTALL LOCATING TAPE ON ALL BURIED SEWER PIPE. PLACEMENT OR DISPOSAL ARE MADE WITH THE APPROPRIATE PROPERTY OWNERS. VB - VALVE BOX 28. ALL TREE PROTECTION AND EROSION AND SEDIMENTATION CONTROLS SHALL BE 10. LOCATION OF EXISTING UTILITIES SHOWN ON THESE PLANS ARE COMPILED IMPLEMENTED BEFORE CONSTRUCTION COMMENCES AND SHALL NOT BE REMOVED WL - WATER LINE BASED ON THE BEST INFORMATION AVAILABLE. THESE LOCATIONS ARE NOT UNTIL RE -VEGETATION HAS BEEN ESTABLISHED. INTENDED TO BE EXACT OR COMPLETE. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES AND FIELD VERIFY THE LOCATION 29. THERE IS NO PAY ITEM FOR DEWATERING AND NO SEPARATE PAYMENT WILL BE WM - WATER METER AND DEPTH OF ALL UTILITIES PRIOR TO CONSTRUCTION. LOCATE WELL AHEAD MADE FOR DEWATERING. ANY DEWATERING OF THE TRENCH REQUIRED IS THE OF PIPE LAYING OPERATIONS TO ALLOW FOR ADJUSTMENT TO SEWER FORCE MAIN RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCLUDED IN THE UNIT WV - WATER VALVE ALIGNMENT AND ELEVATION AS REQUIRED. NO SEPARATE PAYMENT WILL BE MADE PRICE BID FOR THE PIPE. FOR FIELD VERIFICATION OR ADJUSTMENT OF DEPTH AS REQUIRED. ADJUSTMENTS TO LAYOUT SHOWN SHALL BE SUBJECT TO ENGINEER APPROVAL. CONTRACTOR 30. RECORD AND SUPPLY TO THE ENGINEER THE FOLLOWING SHALL REPAIR, AT HIS OWN EXPENSE, ANY DAMAGE CAUSED BY CONSTRUCTION- INFORMATION: RELATED ACTIVITIES TO EXISTING UTILITY SERVICE LINES. A. LOCATION AND ELEVATION OF ALL APPURTENANT CONNECTIONS. B. "AS -BUILT" INVERTS AND PROFILE OF CONSTRUCTED PIPELINE. 11. IN THE EVENT OF DAMAGE TO EXISTING UTILITIES, STOP WORK IMMEDIATELY, TAKE NECESSARY PRECAUTIONS TO PREVENT INJURY OR FURTHER DAMAGE, C. THE LOCATION OF ALL UTILITIES CROSSED AND THE NEW LOCATION AND NOTIFY PROPER AUTHORITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR AND DEPTH OF ALL RELOCATED AND/OR ADJUSTED UTILITIES. RESTORING/REPAIRING ALL EXISTING STRUCTURES, CONDUITS, OR OTHER UTILITIES DAMAGED BY CONTRACTORS OPERATIONS AT NO COST TO OWNER. 31. ALL AREAS WHERE THE EXCAVATION FOR INSTALLING THE NEW FORCE MAIN IS PLAN AND PROFILE SHEETS GENERAL NOTES WITHIN THE 1:1 SLOPE FROM THE EDGE OF PAVEMENT MAINTAINED BY NCDOT WILL REQUIRE 12. ALL MAIN -LINE VALVES ARE PLUG VALVES AND SHALL BE SAME SIZE AS SHORING. WHERE SHORING IS REQUIRED DURING THE GRAVITY LINE SIZE. OPERATING NUTS SHALL EXTEND WITHIN 2 FEET OF GROUND SURFACE. SEWER OR SEWER FORCE MAIN INSTALLATION, INSTALL SHORING TO THE DEPTH REQUIRED TO PROTECT THE ADJACENT ROADWAY. THE TOP OF THE SHORING MUST BE EVEN WITH THE GROUND OR THE ROADWAY, WHICHEVER IS 13. RECONSTRUCT ALL ROAD SHOULDERS, DRAINAGE DITCHES AND SWALES HIGHER. PIPE MUST BE INSTALLED AND TRENCH MUST BE COMPLETELY 1, MATCHLINES ARE ONLY PROVIDED WHEN PIPE FUNCTION IS CONTINUED DISTURBED BY CONSTRUCTION ACTIVITIES TO THEIR ORIGINAL GRADE AND LOCATION. RESTORED AND TAMPED BEFORE SHORING IS TO BE REMOVED. PROVIDE ON REFERENCED SHEET. NCDOT APPROVED TRAFFIC CONTROL IN AREAS WHERE SHORING IS REQUIRED. 14. AIR RELEASE VALVES ARE SHOWN AT HIGH POINTS ALONG THE SEWER FORCE V1 12/2008 REGULATORY SUBMITTAL ISSUE DATE I DESCRIPTION MAIN AND LOW PRESSURE SEWER ROUTE. INSTALL SEWER FORCE MAIN AND LOW 32. ANY DAMAGE TO NCDOT DRAINAGE SYSTEMS ARE TO BE REPLACED PRESSURE SEWER SO THAT THE LOCATION OF THE AIR RELEASE VALVES WILL IMMEDIATELY WITH LIKE KIND DRAINAGE PIPES AND STRUCTURES. NO ALSO REPRESENT THE HIGH POINT IN THE SEWER FORCE MAIN AND LOW OBSTRUCTIONS TO EXISTING DITCHES WILL BE ALLOWED. PRESSURE SEWER. THE AIR RELEASE VALVES SHALL BE PLACED ON THE RIGHT-OF-WAY LIINE, WHEN IN THE NCDOT RIGHT-OF-WAY. 33. ALL TOPOGRAPHIC SURVEY INFORMATION WAS PROVIDED BY STEWART 15. ALL BORES SHALL MAINTAIN A MINIMUM OF 18 INCHES CLEARANCE BETWEEN ENGINEERING INC. SCP AND EXISTING UTILITIES. WATER, TELEPHONE, AND CABLE TV LINES ARE ASSUMED TO HAVE A MINIMUM OF 3 FEET OF COVER. INSTALL AND MAINTAIN 34. UTILITY LOCATION PHONE NUMBERS ARE AS FOLLOWS CONCRETE BARRIERS AROUND BORE PITS. - NC ONE CALL- 1-800-632-4949 - BRUNSWICK COUNTY PUBLIC UTILITIES- 910-253-2860 16. AT ALL FITTINGS AND/OR BENDS, CONTRACTOR SHALL USE PIPE - ATMC- 910-754-4317 MANUFACTURER'S RECOMMENDED RESTRAINED JOINT SYSTEM (SEE - NCDOT SIGNALS- 1-888-813-6508 SPECIFICATION SECTIONS 15060 AND 15062). RESTRAINED JOINT SYSTEM CONTACT OTHER UTILITIES AS REQUIRED. SHALL BE SUBJECT TO ENGINEER'S APPROVAL. (THE USE OF 'GRIPPER' TYPE GASKETS IS PROHIBITED). PROJECT MANAGERI E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY1 K. BARRETT, PE I PROJECT NUMBER 1008176-68249-0181 SEAI�� 12434 S °. G' �.FNGIt'IEE�..•S ��sl 1 yI o9 BRUNSWI;CK,COUNTY PUBLIC;UTILtIES CALABA SM W. ASTEWATER COLLECTION SYSTMEXPANSION { BRUNSWICK COUNTY NORTH CAROLINA PROJECT SPECIFIC ABBREVIATIONS GENERAL PROJECT NOTES 0 1" 2" FILENAME OOG-06.dwg SHEET SCALE NO SCALE OOG'06 D C B A 60-2 Chandlers Lane I Sunset Beach, NC 296 2 1 3 "SANITARY SEWER" NON PRESSURE SEWER GUARD 316 TO BE CAST ON LID TYPE FRAME AND COVER SS IN TRAFFIC AREA UNLESS SPECIFIED PLASTIC IN NON OTHERWISE ON DRAWINGS TRAFFIC AREA. USE UP TO THREE COURSES /Yi?✓ x OF BRICK FOR ADJUSTMENT v 7" 24'-1 3/4" 7" MIN MIN Z MH STEPS, 12" O.C. CONE CO — — 6" EXTERNAL SEAL -- WRAP, ALL BURIED JOINTS N STRAIGHT WALL OF w MANHOLE TO BE RISER LOCATED OVER INFLUENT PIPE II I BASE SECTION PER PLANS < w f— 6' MIN Ir CONCRETE 2" FALL I fit- -tom INVERT 6" MIN FLEXIBLE COUPLING CAST IN BASE 6" (MIN) OR INSTALLED IN CORED HOLE WITH EXTENDED BASE STAINLESS STEEL COMPRESSION DEVICE. 6" LAYER NOTE: SEE SPECIFICATION SECTION 02515 FOR OF GRANULAR ADDITIONAL REQUIREMENTS. BEDDING MATERIAL STANDARD PRECAST MANHOLE DETAIL NTS 8"X 1/2" S PLATE STRAI 1 TYP 1 1/2" Ju 2- 3/4"0 X 4" W/HEX NUTS (T'r 10" 8"X 1/2" Th 10"X 4"X 1 / I J (SHOE -BEND ENDS UP 1/2") STEEL SPIDER DETAIL NTS 3" MIN BOLT THRU —— — — SUPPORT AND TYP BOTH LEGS }- 0 0 FLANGE O BOLTS ADJUST L3x3x3/8 ' -- MAINTAIN TOP LEG NORMAL TO PIPE E d Q U M a- �7 3/4" EPDXY ADHE` ANCHORS, TYPICAL - NOTE: ALL MATERIALS AND FASTENERS SHALL BE 316 SS. RISER PIPE SUPPORT DETAIL NTS IMA. MDR Engineering, Inc. of the Carolinas 780-2 Chandlers Lane I Sunset Beach. NC 28648 VARIES 3'-0" MAX 5 I 6 r_I'nUF J+ r l'. E W� 1/4" RIM RAISED 1/4" "W'ERR'r �,� WE:R 1" HOLE TAPERED TO 1 1/8" MANHOLE ON REVERSE SIDE USE GROUT TO FORM NEW INVERT AND BENCH 1'-11 1/4" TO DIRECT FLOW DOWNSTREAM 1'-8 1/2" 2'-1 1/4" 1'-11 1 Z" 1 1/4" SURFACE TO BE MACHINED /2" RIBS EQUALLY SPACED SURFACE TO BE MACHINED ;'RAVi �'I �,YEs� 8 FINISHED GRADE COMMON TRENCH BACKFILL 12,. CAREFULLY COMPACTED BACKFILL 4" MIN �t�jr�\' COMPACTED GRANULAR MATERIAL NOTE: SEE SPECIFICATION SECTIONS 02221, 15060, AND 15062. FLANGED TEE BEDDING DETAIL BLINDFLANGEPIPE FOR GRAVITY DIP GRAVITY SEWER � SEWER AND 90' BEND FOR NTS LOW PRESSURE SEWER. FINISHED GRADE CORE DRILL OPENING COMMON TRENCH BACKFILL STAINLESS STEEL STRAPS (TYP) 90' FLANGED 12" BASE FITTING 4" MIN Cr�ivfC(,E1'L LsE_NCI-I p — — — — — — — �,— _ — — — NOTES: 1. PROVIDE WATERTIGHT SEAL BETWEEN MANHOLE WALL AND PIPE USING LINK -SEAL ON CONCRETE MANHOLES. 1'-10 1/4" 1/2" 2. INSIDE DROP MANHOLE IS ONLY TO BE USED IF 4-5/ 8' 2'-1 2" 4 5 8' DIRECTED BY ENGINEER. USE OUTSIDE DROP UNLESS OTHERWISE DIRECTED BY ENGINEER. 2'-10 1/2" STANDARD MANHOLE FRAME AND COVER INSIDE DROP MANHOLE NTS NTS SHOULDER DITCH PAVEMENT I 1'- 6" (MAX) 10" (MIN) 12'-0" MAXIMUM 3' MIN. 8" BRICK BULKHEAD AT EACH 3' MIN. BETWEEN SPACERS 3' MIN. END OF CASING PIPE (WATERTIGHT) 1 (SEE NOTE 1) CH ANGLE THREE CASING SPACERS PROVIDE 3/4" WEEP PER PIPE JOINT AS REQUIRED HOLE IN BULKHEAD CLEAR CARRIER PIPE TO MEET MAXIMUM SPACING STEEL CASING AT LOW END OF CASING TS AS PIPE PIPE AND 1/4 CU.YD. OF CRUSHED STONE !UIRED AT WEEP HOLE. CASING SPACERS SHALL BE SPACED A MAXIMUM OF 1'-6" NOTES: TYP FROM EACH SIDE OF JOINT 1. ENDS OF CASING CAN BE SEALED USING A MODEL AC CASING END PLUGS PULL -ON END SEAL GASKET AS MANUFACTURED BY ADVANCE PRODUCT SYSTEMS, INC. OR APPROVED EQUAL CASING SHALL BE PLUGGED ON BOTH ENDS IN LIEU OF BRICK BULKHEAD. BEFORE BACKFILLING ELEVATION TYPICAL PIPE CROSSING NTS PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 FOR APPROVAL ISSUE I DATE I DESCRIPTION PROJECT NUMBER 008176-68249-018 .�'o, ` i� CARO IE A 2434 FIIyIo9 ��•.FN61NtE�•'S•Sr ` F,p�� WIti��.�•F a•n••N••• BRUNS PUB_ CALABA. COLLECTION WICK COUNTY OUNTY 'IL STIES S�'WATER �M_EXPANSION �ii!Y��� COMPACTED NOTE: SEE SPECIFICATION SECTIONS 02221, 15060, AND 15064. PIPE BEDDING PVC GRAVITY SEWER Am"k a&y �'NISHED GRADE )MMON TRENCH BACKFILL 4" MIN CAREFULLY COMPACTED BACKFILL 71 COMPACTED GRANULAR MATERIAL NOTE: SEE SPECIFICATION SECTIONS 02221, 15060, 15062, AND 15064. PIPE BEDDING DETAIL,PVC AND DIP NTS VARIES — SEE PLAN SURFACING oo° o°°000°0000 /./.�% \j\ o0o00 000°0000000000 \/ a" MIN. //\oo oo° oo °o °o °o NOTES: SUBGRADE 1. SURFACING TO BE CRUSHED ROCK WITH THE FOLLOWING GRADATIONS AND PROPERTIES: 1 3/4 INCH 0 7/8 INCH 10-35 3/8 INCH 30-50 NO. 4 45-65 NO. 40 70-85 MAXIMUM LIQUID LIMIT 35 MAXIMUM PLASTICITY INDEX 10 MAXIMUM WET BALL MILL 50 MAXIMUM INCREASE IN PASSING O. FROM WET BALL ALL WEATHENR 40ACCESSL� DRIVE DETAIL ,/ NTS NORTH CAROLINA I STANDARD SEWER DETAILS 0 1" 2" FILENAME OOC-01.dwg SHEET SCALE OOC-01 IN C I IA 6 i 7 ( 8 G d e . PROVIDE SINGLE ROW BRING WIRE WITHIN CARDINAL RED. THE ENTIRE SIGN IS OVERLAID WITH FLEXCON EVL 400 VINYL #V-29, STD WT STL PIPE OF SEALS FOR PIPES _ + 4" OF COVER LAMINATED AT 40 PSI. ALL LETTERING IS STANDARD BOLD CONDENSED. SLEEVE, GALV AFTER - LESS THAN 16" DIA. FABRICATION 3/16 b PROVIDE DOUBLE ROW OF r PIPE THRU e SEALS FOR PIPE ANNULAR SEAL WALL OR FLOOR ' 16" DIA AND LARGER: o ANVIL FIG. 264 LU APPROVED EQUAL PIPE THRU WALL OR FLOOR a4"Z GALV. STD. PIPE NOTE: PROVIDE TRACER WIRE ON ALL J�wwx cN r - NON-FERROUS PIPELINES. Property Operty �T Brunswick County 1/4 (4)-5/8"0 CIP OR Public Utilities EPDXY ANCHORS (DRILLED e _ & SET IN 6" EPDXY) IN CASE OF EMERGENCY AS RECOMMENDED T/CONC. SLAB AS RECOMMENDED WALL SLEEVE OR ALARM BY ANNULAR 1/4"x3' STEEL IE 1" NON -SHRINK GROUT, 6" (MIN.) I p1 SEAL MFR SEEP RING BY ANNULAR SEAL �" GALV. STEEL SHIMS u u CQII J1�-45�-�51� ° MANUFACTURER C�1 1 q INTERIOR, DRY T/2 BURIED, WET OR v AS REQ'D EQ. EQ 12 GA. UNSHIELDED COPPER WIRE or 10-371-34lO CONTACT BRUNSWICK COUNTY OR TOP SIDE I T<8" BOTTOM SIDE T/2 PUBLIC UTILITIES FOR SEWAGE SLS --------------- LIFT STATION NAME T 8" a� aoa AUTHORIZED PERSNNEL ONLY GALV. BASE PL 5 8x9" SQ. aaa �+— 10' MAX. �I NOTE: TYPICAL PENETRATION OF BURIED PIPE THROUGH PRECAST STRUCTURE. I I PIPE SLEEVE WITH ANNULAR SEAL PIPE SUPPORT TYPE 1 NTS NTS 1 1/2" POLYETHYLENE TAPE WRAPPED AROUND TWICE 2 RINGS OF 3 REINFORCEMENT BAR AS SHOWN VALVE TRACER WIRE DETAIL �31 7 3 4" DIA. 7 1 /8" DIA. _ / \ 3'-2 1/ 1 i 2 1/2" 2 1/4" 7 9 1/2" 1 1'-0 1/2" SEWER 1/2" A� PLAN 6 15/16" 3) � - - - - - i 1/2" T t6 5/8" 11/16" (TYP.) 8" DIA. SECTION A —A STANDARD TELESCOPING VALVE BOX DETAIL r5�) NTS HDR Engineering, Inc. of the Carolinas 780-2 Chandlers Lane I Sunset Beach, NC 28648 3 0 PIPE ANNULAR LINK -SEAL i 5 NTS I SEWER I O 1 NON -SHRINK GROUT RING AROUND CASTING \ / 14" DIA. 23" DIA. — PLAN MANHOLE STEPS TO THE BOTTOM AT / 16" ON CENTER —/ 10 3/4" MASTIC SEALANT -H 60" ID PRECAST MANHOLE SAND FILL \ 3,000 PSI CONCRETE (MIN.) RISER SECTION MANUFACTURER'S STANDARD N /—GROUND BACKFLUSH ATTACHMENT — CORED HOLES FOR PIPE zn,7 4°�3,000 P.S.I.a ° i, i i , i 2" CONCRETE T\ . . . A\ } FOOTING 00 2"� i i COMPACTED EARTH IF71 BCPU PUMP STATION SIGN SPECIFICATIONS MATERIAL: ANODIZED ALUMINUM, #5052 080 THICK SIZE: 18" WIDE X 24" HIGH WITH 1.5" RADIUS ON ALL CORNERS BACKGROUND: 3-M ENGINEER GRADE SCOTCHLITE REFLECTIVE FILM ALL COPY AND BORDER IS 3-M SCOTCHCAL VINYL FILM, SAPPHIRE BLUE WITH THE EXCEPTION OF THE PHONE NUMBER AND "AUTHORIZED PERSONNEL ONLY" WHICH ARE 3-M SCOTCHCAL. PUMP STATION SIGN DETAIL r4 CJ NTS STANDARD MANHOLE FRAME AND COVER (VENTED) 9" IN NCDOT RIGHTS -OF -WAY PRE -CAST FLAT SLAB TOP -16f~ FINISH GRADE , 2 -O.� 1/2" GATE VALVE COMBINATION AIR/VACUUM RELEASE VALVE 6" MIN --I E-- ON APPLICATIONS WHERE 2" GATE VALVE NON -SHRINK GROUT PRESSURE SWITCHES ARE TO MAKE WATERPROOF PRESENT, UTILIZE TEE AND INSTALL DOWNSTREAM / OF PULSATION DAMPER 2'-6" 5'-0' 20' SECTION OF DIP CENTERED IN VAULT IN -SHRINK GROUT �• ate• s� sue• ate•- 1 6" GRANULAR BACKFILL i■Ila_IIAII� II®II®I�MATERIAL 7' 6 1/2" UNDISTURBED EARTH `8" GRANULAR FILL VALVE BOX NOTES: 27" DIA. 110. SECTION B—B NOTE: TOTAL WEIGHT OF PROTECTIVE RING IS 115 LBS (MIN.). PROTECTIVE RING DETAIL NTS PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 FOR APPROVAL ISSUE I DATE DESCRIPTION PROJECT NUMBER 00817 6-68249-018 1 DRESS/p � .9 1�S-EE A �01/ 12434 t llyloi o °•,,*o NlE ,.•°c� pr •••.•IIII•Wl L. F•��, 1. DIRECT TAP DIP FOR AIR VALVE ASSEMBLY; NO SADDLES. 2. FINISH GRADE SHALL BE 9 INCHES BELOW MANHOLE FRAME AND COVER WHEN IN NCDOT RIGHT-OF-WAY, OTHERWISE, MANHOLE FRAME AND COVER SHOULD BE 2 INCHES ABOVE FINISHED GRADE. 3. LOCATE AT RIGHT-OF-WAY LINE ALONG NC DOT MAINTAINED ROADS. AIR RELEASE VALVE DETAIL NTS BRUNSWI_! PUBLIC CALABASH. COLLECTION 0Y `�%vm BRUNSWICK COUNTY PRESSURE GAUGE (MOUNT VERTICAL) UNION 1/2" NEEDLE VALVE 1/2" STAINLESS STEEL PIPE, USE PIPE SADDLE ON PVC, DIRECT TAP DIP PRESSURE INDICATOR DETAIL NTS A_ OUNTY IITIES STANDARD SEWER DETAILS EWATER EXPANSION 0 1" 2" FILENAME OOC-02.dwg SHEET NORTH CAROLINA SCALE OOC-02 D C B A 1 I 2 I 3 414- ""- SIPHON BREAK - Z 00 TOP OF GROUND SLAB LINE NOTE: wwx Qa 1. NON -FREEZE POST TYPE. 2, HOSE BIBB SHALL ACCOMMODATE STANDARD 3/4" GARDEN HOSE. 2'x2'x6" THICK N 3. MATCH DRAIN PORT SIZE PROVIDED BY CONCRETE PAD MANUFACTURER. 3„ LONG NIPPLE (NOTE 3) VALVE HOUSING BELOW FROST LINE 1" SUPPLY LINE 8 CF 1 /2., DRAIN ROCK YARD HYDRANT DETAIL 1/2" GRADE 60 STEEL REINFORCEMENT COPOLYMER POLYPROPYLENE PLASTIC MANHOLE STEP NO SCALE GENERATOR FINISHED GRADE 0' •- y #5 BAR 0 6" LAYER OF SLAB SPACING COMPACTED (BEND AS SHOWN) GRANULAR BEDDING 2-#5 BARS (CONTINUOUS) ELEVATION VIEW GENERATOR PAD DETAIL NTS FMA. HDR Engineering, Inc. of the Carolinas 780-2 Chandlers Lane I Sunset Beach, NC 28648 0 5 LEGEND POURED CONCRETE BLOCKS UNDISTURBED EARTH NOTE 1. THESE DETAILS ARE FOR BOTH VERTICALLY AND HORIZONTALLY LAID PIPE. 2. POURED IN PLACE CONCRETE SHALL BE 3000 PSI. 3. LEAVE JOINTS CLEAR OF CONCRETE FOR EASY ACCESS. 4. POLYETHYLENE SHALL BE WRAPPED AROUND FITTINGS. 5. TABLE ASSUMES A MAX. WATER PRESSURE OF 150 PSI, BEARING AREA OF THRUST BLOCK IN SQUARE FEET FITTING SIZE 90' FITTING 45' FITTING 224• FITTING 114' FITTING TEE FITTING PLUG OR CAP 1.5" 1.0 1.0 1.0 1.0 1.0 1.0 2" 1.0 1.0 1.0 1.0 1.0 1.0 3" 1.5 1.0 1.0 1.0 1.5 1.5 4" 2.5 1.5 1.0 1.0 2.0 2.0 6" 5.0 3.0 1.5 1.0 4.0 4.0 CONCRETE BLOCKING DETAIL NTS 3' MIN ALL SIDES 1/2" CHAMFER ALL AROUND SEE SITE PLAN FOR TOC EL #5 BARS @ 12" O.C.E.W. @ MIDTHICKNESS 3/4 CHAMFER ® 2" BRASS MARKER EACH CORNER PLATE W/ANCHOR BRASS MARKER PLATE O 4%4" SQUARE M 4-#3 RE -BAR V PLATE W/DIRECTIONAL EXISTING GROUND N ARROW POINTED TO VALVE & DISTANCE TO NEAREST FOOT PRECAST CONCRETE NOTES POST (4,000 PSI) ::f, 1. FORCE MAIN LINE VALVE MARKERS SHALL BE PAINTED FEDERAL SAFETY GREEN AND MARKED AS FOLLOWS: MV - MAIN VALVE AV - AIR RELEASE VALVE 2. PLACE MARKER AT EACH PLUG VALVE AND AIR RELEASE VALVE AS APPROPRIATE. 3. NO MARKERS ARE REQUIRED ON THE PUMP STATION SITE. 4. LOCATE AT RIGHT-OF-WAY LINE ALONG NC DOT MAINTAINED ROADS. CONCRETE MARKER DETAIL /1*7 NTS PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 FOR APPROVAL ISSUE I DATE I DESCRIPTION PROJECT NUMBER 008176-68249-01E 4r- -v7 y . SE • 2434 ''•o9/C ww.\P•,. on 7 GRADE PIPE DIAMETER L W H 1.5" 2' 2' 3' 2" 2' 2' 3' 3" 2' 2' 3' 4" 2' 2' 3' 6" 5' 3' 3' MJ PLUG, VALVE OR REDUCER ♦• D .4 . W NOTES PL 2 #5 RODS OVER FITTING & EMBED 18"IN CONCRETE 1. CONCRETE ANCHOR TO BE USED ONLY WHERE CONCRETE BLOCKING OR RESTRAINT JOINT PIPE CAN NOT BE USED AND WHEN APPROVED BY OWNER. a aP o 2. TABLES ASSUME A MAX WATER PRESSURE OF 150 PS CONCRETE: 3000 PSI ao FITTING VOLUME OF ANCHOR BLOCK IN CUBIC YARD SIZE 90' BEND 45" BEND 22-1/2' BEND 11-1/4' BEND 1.5" 1.5 0.8 0.5 0.5 2" 1.5 0.8 0.5 0.5 3" 1.5 0.8 0.5 0.5 4" 1.5 0.8 0.5 0.5 6" 2.5 1.5 1.0 0.5 CONCR NTS ANCHOR DETAIL / 4 LENGTH OF PIPE ON EACH SIDE OF FITTING OR VALVE THAT MUST BE RESTRAINED FITTING SIZE 90' FITTING 45' FITTING 22 FITTING FITTING FITTING TEE BRANCH PLUG OR CAP VALVE REDUCER 1.5" 25' 10' 10' 10' 50' 60' 60' 30' 2" 25' 10' 10' 10' 50' 60, 60' 30, 3" 25' 10' 10' 10' 50' 60' 60, 30' ' 4" 30, 15, 10' 10' 60' 60' 60' 30' 6" 40' 20' 10' 10' 90' 90' 90' 50' NOTES: 1. IN LIEU OF POURING BLOCKING, CONTRACTOR MAY ELECT TO INSTALL RESTRAINED JOINT PIPE ON ALL JOINTS WITHIN LENGTH SPECIFIED IN THE TABLE AT NO ADDITIONAL COST TO OWNER. 2. TABLE ASSUMES A MAX. FLUID PRESSURE OF 150 PSI. 3. SEE SPECIFICATION SECTION 15060 FOR ADDITIONAL REQUIREMENTS. RESTRAINED JOINT/ RESTRAINT HARNESSES DETAIL NTS BRUNSW1,C:K 0UNTY PUBIC, UT:ITIES CALABASH►S EWATER COLLECTION`° YS1tT V EXPANSION BRUNSWICK COUNTY NORTH CAROLINA STANDARD DETAILS 0 1" 2" FILENAME OOC-03.dwg SHEET SCALE OOC-03 B ABS OR SOLVENT CEMENT SEAL PVC SADDLE SEWER MAIN FLOW I STAINLESS STEEL BANDSI FINISHED - PVC PIPE zl GRADE w —� SPECIAL GASKET BY MFR V) wl WITH SPECIAL SEALANT ui CAST IRON SADDLE <I of UJ a-1 SEWER MAIN 01 PLUG FLOW STAINLESS STEEL BANDS DUCTILE IRON PIPE I 2 I 3 I 4 ' 5 I 6 PERMANENT EASEMENT LIMIT OR R.O.W. CAST OR DUCTILE 1'-0" IRON 4" THREADED CLEANOUT ADAPTOR 4"x4"x6' TREATED CAST IRON BOX IN GRASSED TIMBER MARKER I AREAS OR 2'-0" SQUARE OR FINISHED ROUND CONCRETE PAD, 6" THICK 4° GRADE IN PAVED AREAS CLEANOUT PLUG SANITARY SEWER SIDEWALK 6' ROADWAY 1 I I = I - _ , I I I-� I I=1 I I -I I I=1I=1 I I I-' 0 4V. 2° PLAN I CURB &GUTTER 18" MIN SAME MATERIAL CAST OR DUCTILE IRON 4" THREADED CLEANOUT ADAPTER 4' MIN 1/8 BEND 7C r1/6 OR 1/8 BEND II MINIMUM GRADE [IF 1/8' PER FOOT WATER TIGHT PLUG LONG TURN TEE WYE I -�1El I 1=1I SEWER �I �� �- WYE SERVICE PIPE AS SPECIFIED 1/8 BEND II LINE �� COMPACTED SOIL TAP TO BE MADE ON THE TOP QUARTER OF THE MAIN DEPTH < 20 FEET - CLASS "A" BEDDING MIN GRADIENT "Y" OR TAPPING SADDLE UNDERCUT TRENCH BOTTOM 6 INCHES MINIMUM BELOW PIPE DEPENDING ON NEW OR EXISTING MAIN 1/8" PER FT. FILL PIPE TO SPRING LINE WITH N0. 57 OR 67 STONE DEPTH >_20 FEET - CLASS "B" BEDDING ELEVATION 9 UNDERCUT TRENCH BOTTOM 6 INCHES MINIMUM BELOW PIPE TAPPING SADDLE & • FILL TO 6 INCHES ABOVE PIPE WITH NO. 57 OR 67 ADAPTER AS REQ'D STONE INSTALLATIONS THAT EXCEED 13 FEET DEPTH SHALL BE DIP 45' SANITARY SEWER GRAVITY TAPS DETAIL jl�i 3 STRAND 12CA BARBED NOT TO SCALE WIRE W/14GA BARS ANGLED SEAL WELD ALL JOINTS, TYP AT 45 DEGREE ANGLE. I PUMP STATION SIGN 1 n==0 CAP INDIVIDUAL TREE GROUP OF TREES 3" TERMINAL POST (AT CORNERS AND ENDS) STRETCHER DRIP LINE BAR rDIAREE POST \BRACING \STRETCHER BAR BANDS1ORANGE MESH TREIPROTECTION FENCE -I I- 3 STRAND 12GA BARBED WIRE W/14GA BARS ANGLED AT 45 DEGREE ANGLE. CAP TOP RAIL' CHAIN Y2" LINE POST - CHAIN LINK FABRIC (SEE SPECS FOR MESH AND SELVAGE) TRUSS ROD TENSION WIRE 7GA GALVANIZED AND STEEL T-POSTS 1 I F 1T51I , \ an TURNBUCKLE 0 POST SPACING / (10' MAX) DRIP LINE (VARIES) TREE FENCE LOCATION CRITICAL ROOT ZONE J - - / PROTECTION (LIMITS OF CRITICAL ROOT ZONE) FENCE RADIUS = 1 FT PER INCH OF TRUNK DIAMETER TREE PROTECTION DETAIL NTS faq MDR Engineering, Inc. of the Carolinas 780-2 Chandlers Lane I Sunset Beach, NC 29948 CONC. FOOTING 12" DIA. TYPICAL ELEVATION 12" DIA. NOTE: SEE SPECIFICATION SECTION 02444 FOR ADDITIONAL REQUIREMENTS. CHAIN LINK FENCING DETAIL n NOT TO SCALE PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 IFOR APPROVAL ISSUE DATE I DESCRIPTION PROJECT NUMBER 008176-68249-018 0 I LOCKING o DEVICE - I 0 BRUNSWICH PUBLIC U` CALABASH p COLLECTION SYST BRUNSWICK COUNTY 1.90" O.D. (2.72 LB/FT) FRAME, TYP. -� PADLOCK HOLE TURNBUCKLE X 8 EXISTING MIN 2" BIT CONCRETE PAVEMENT SURFACE COURSEI MIN. 4" ASPHALTIC) EXISTING.�' BASE'COURSE BASE COURSE 6" AGGREGATE -' BASE COURSE 6" 12"1 DIA. 12" 6" CAREFULLY COMPACTED MIN MIN BACKFILL TRENCH PIPE NOTES: 1. EXISTING PAVEMENT SHALL BE CUT WITH A SAW. ASPHALT DRIVEWAY REPLACEMENT DETAIL NTS --�-EXISTING RIGID REPLACEMENT TYPE PAVEMENT CONC. 3000 PSI __ _.- „`. 2 �f CAREFULLY COMPACTED BACKFILL 12" 12" DIA. 12" 12" MIN MIN TRENCH PIPE NOTES: 1. EXISTING PAVEMENT SHALL BE CUT WITH A SAW. 2. ALL REPLACEMENT CONCRETE SHALL BE 2" THICKER THAN EXISTING CONCRETE. CONCRETE DRIVEWAY REPLACEMENT DETAIL r3 NTS GATE LEAF WIDTH VARIES, SEE PLANS OFFSET HINGES, TYP. INTERIOR BRACE n 8' USS ROD 1.90" OD (2.72 LB/FT) STRETCHER i--CHAIN LINK FABRIC 1 112" TYP. MA INNER CLEARANCE,: 2 MIN., 4 MAX. CONC. FOOTING EMBEDDED 1" DIA. GALV. GRAVEL OR PAVED ROAD, STEEL PIPE STRIKE SEE SITE GRADING PLAN 12' FOOTING DIA., TYP. DIA. (SEE SCHEDULE) NOTES: 1. SINGLE LEAF GATES TO BE REINFORCED SIMILAR TO DOUBLE SWING GATE DETAIL. 2. PROVIDE EMERGENCY CONTACT SIGN, TO BE MOUNTED ON ACCESS GATE WITH S.ST. HARDWARE. COORDINATE THE TEXT ON THE SIGN WITH THE OWNER. TRUSS ROD GATE POST, TYP. (SEE SCHEDULE) GATE POST SCHEDULE LEAF SPAN POST O.D. WEIGHT CONC. FOOTING UP TO 4' 2 7/8" 5.79 LB/FT 24" DIA. 6' TO 13' 4" 9.11 LB/FT 24" DIA. 13' TO 18' 6 5/8" 18.97 LB/FT 36" DIA. OVER 18' 8 5/8" 28.55 LB/FT 48" DIA. 3. SEE SPECIFICATIONS FOR MORE DETAILS. CHAIN LINK DOUBLE -SWING GATE NOT TO SCALE OUNTY STANDARD CIVIL DETAILS 'I EWATER I�EXPANSION 0 1" 2" FILENAME OOC-04.dwg SHEET NORTH CAROLINA SCALE AS NOTED OOC-04 D C B A 2 10 I , I i! o c Spec/ G 3 I 4 I 5 I OCHECK ODAM, TYPICAL A NOTE: ELEVATION A IS NOT HIGHER THAN ELEVATION B ELEVATION I ��/R BOTTOM 4{ /RFC Rio FFiI CHECK DAM CENTERLINE I I .I FFti UT CF OF CHANNEL GALVANIZED WOVEN B WIRE FIELD FENCE, I 14 GAUGE, WITH 6 I I MAXIMUM VERTICAL STAY SPACING SEDIMENT FENCE FABRIC SEE NOTE 1 NOTES. Miff' 1. FABRIC, PER NCDENR 6.62, TO 1,0 BE ANCHORED IN THE TRENCH 2 8" DOWN AND 4" HORIZONTAL AND THEN BACKFILLED WITH . 1. / $ EXISTING EARTH AND COMPACTED. 2. POSTS TO BE MIN. OF — 2'-0" IN GROUND. 3. BRACE POSTS WHERE III NECESSARY. I —III 4. ATTACH FABRIC WIRE AND I f POSTS WITH METAL RUNGS IP TIES (50 LB I — III III ON PLASTIC Z MIN. TENSILE) _� I I I Tr li II I I I i I 5- POST SHALL BE 5' (MIN.) METAL POST _ 6� WEIGHING A MIN. 1.33 LB PER LF, MANUFACTURED WITH CLIPS. 6. WATER SHALL NOT BE IMPOUNDED TO A DEPTH GREATER THAN 1.5 FT AT ANY POINT ALONG FENCE. CONTRACTOR SHALL INSTALL A FENCE IMPOUNDMENT OUTLET, SEE DETAILS. SILT FENCE DETAIL f 1 NTS GRADE — a a B a a a a a NC DOT #57 / — COURSE AGGREGATE TOP OF BANK o� J PLAN z NC DOT #57 m 1.5' MIN. COURSE AGGREGATE — C DIVERSION POINT " �!% \\ 24" MAX. STONE /_15ft DEPTH AT CENTER OF �\7 1' CHANNEL FLOWLINE FILTER FABRIC NO. 5 OR NO. 57 SEDIMENT CONTROL STONE. 12" THICK LAYER ON UPSTREAM FACE — C SECTION B—B 2'-0" CLASS B RIP RAP EXISTING GROUND 2 24" MAX. STONE /tea a �1 DEPTH AT CENTER OF CHANNEL FLOWLINE FILTER FABRIC j 4' TO 6' WIDTH, U.N.O. SECTION C—C STONE CHECK DAM DETAIL NTS NOTE: STRUCTURAL STONE SHALL BE (CLASS "B") STONE FOR EROSION CONTROL PURPOSES. SEDIMENT CONTROL STONE SHALL BE NO. 5 OR NO. 57 STONE. SEDIMENT SILTFENCE CONTROL STONE 1'-6 MAX a 1' THICK \ 2:1 2 \-STRUCTURAL STONE CROSS SECTION FRONT FENCE IMPOUNDMENT OUTLET DETAIL n 9' AAlm 2 TOP _.. --- -- -- JCE NTS NTS IFUR HDR Engineering, Inc. of the Carolinas 780-2 Chandlers Lane I Sunset Beach, NC 28648 PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 FOR APPROVAL ISSUE DATE I DESCRIPTION PROJECT NUMBER 008176-68249-01 \4*0'®r SSI�;y9f . SEA 12434 I Ip9 �._ 0 With-•�.. GENERAL EROSION CONTROL NOTES: 1 CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL EROSION CONTROL MEASURES INSTALLED FOR THE FULL DURATION OF THIS CONTRACT. ., ,..ar , r , tr , 2. ALL EROSION CONTROL MEASURES SHALL CONFORM TO i� •. tip/,tr/ r� rL'iTHE STANDARDS SET FORTH IN THE • -.-..•SEDIMENTSTATE CONTROL AND DESIGN MANUAL. FLOW— 3. PRIOR TO COMMENCING LAND DISTURBANCE ACTIVITY, THE LIMITS OF - AND ACCURATELY DEMARCATED WITH STAKES, RIBBONS, OR OTHER APPROPRIATE MEANS. THE LOCATION AND Impi ze PIPE (SEE SITE EXTENT OF ALL AUTHORIZED LAND DISTURBANCE ACTIVITY "a 45. ��q PLAN FOR DIA) SHALL BE DEMARCATED FOR THE DURATION OF THE CONSTRUCTION ACTIVITY. NO LAND DISTURBANCE SHALL Mae OCCUR OUTSIDE THE APPROVED LIMITS INDICATED ON ����.A• �; THE APPROVED PLANS. • a r. • • r :,• •� •� •� •� ut.iNC DOT EROSION CONTROL STONE 4. COMPLY WITH THE FOLLOWING CONSTRUCTION SEQUENCE: A. INSTALL ALL TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES PRIOR TO LAND DISTURBANCE. PLAN B. ALL SEDIMENT AND EROSION CONTROL SHALL BE INSPECTED EVERY SEVEN (7) DAYS OR AFTER EACH RAINFALL OCCURRENCE THAT EXCEEDS - • • DAMAGED • INEFFECTIVE •MIN - • • REPLACED, AS NC •• EROSION CONTROLSTONE ROADWAY T C. PROVIDE SILT FENCE AND/OR OTHER CONTROL n SHOULDER DEVICES, AS SHOWN OR REQUIRED, TO CONTROL C-4 I SOIL EROSION -CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED AND 5 STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. SECTION ROCK PIPE INLET DETAIL NTS BRUNS PUB ' F CALABA! COLLECTION BRUNSWICK COUNTY D. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF PIPE (SIZE AS INDICATED CONSTRUCTION UNTIL THE COMPLETION OF ALL ON DRAWINGS) CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. E. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO THE PAVED ROADWAY FROM CONSTRUCTION AREAS. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENTS, AS MAY BE REQUIRED. F. STABILIZE ALL SPOIL AREAS. G. PROVIDE PERMANENT GROUND COVER AS SPECIFIED. H. REMOVE TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES AND MEASURES UPON COMPLETION OF PROJECT. 5. ALL DITCH LINES DISTURBED OR RELOCATED DURING CONSTRUCTION SHALL BE RESTABILIZED BY THE CONTRACTOR. INSTALL A TEMPORARY DITCH LINER OF JUTE OR GEOTEXTILE FABRIC ON THE DITCH BOTTOM AND SIDE SLOPES. 6. INLET PROTECTION WILL BE INSTALLED AROUND EXISTING INLETS AS SHOWN ON THE GRADING DRAINAGE AND EROSION CONTROL PLANS. COMPACTED 2' MIN SOIL K,COUNTY ITI `TIES 'ASSSSS�EWATER TFIV� EXPANSION NORTH CAROLINA TEMPORARY DIVERSION DITCH DETAIL NTS EROSION CONTROL DETAILS 0 1" 2" FILENAME OOC-05.dwg SCALE AS NOTED 7 SHEET OOC-05 C B A INLET GRATE \leU N T S:1. RECESSED CURB INLET MUST CATCH BASINSUSPENSION CORD/RODS BE BLOCKED WHEN USING OVERFLOW FILTER FABRIC SACK. 2. SIZE OF SACK TO BE a FILTER FABRIC SACK DETERMINED BY MANUFACTURER TO SUIT INLET, FRONT VIEW 3. INSTALL BAGS WITHOUT GAPS AT INLET GRATE. 4. FILTER FABRIC SACK SHALL BE "SILTSACK" MANUFACTURED CATCH BASIN p BY ACF ENVIRONMENTAL, INC. 1" REBAR IN HEM a. FOR BAG REMOVAL STORM PIPE _ RUBBER RESTRAINT BLOCKS EXPANSION RESTRAINT TIE FILTER FABRIC SACK SIDE VIEW INLET SEDIMENT PROTECTION a NTS m 8 r a s :9 g 1780-2 Chandlers Lane I Sunset Beath, NC 28949 SECTION u u TEMPORARY FABRIC DROP INLET PROTECTION DETAIL NTS PROJECT MANAGER E. WILLIAMS, PE _ DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 FOR APPROVAL ISSUE DATE DESCRIPTION PROJECT NUMBER 008176 68249 01$ S) DNE BRUNS PUB q CALABI COLLECTIO I BRUNSWICK COUNTY 6 I 7 OUNTY i�°VIES EWATER I�EXPANSION NORTH CAROL EROSION CONTROL DETAILS 0 1" 2,, FILENAME OOC-06.dwg SHEET SCALE OOC-06 I M. n 1 I 2 I 3 NOTES: 1. ALL TAPS WILL BE MADE IN ACCORDANCE ' THREE INCH "S" OR OTHER APPROVED MARKER TO BE STAMPED INTO CURB (IF WITH BRUNSWICK COUNTY SPECIFICATIONS EXISTING) AT SERVICE LOCATION AND AWWA GUIDELINE "ANSI/AWWA C600-93" OR LATEST REVISION FOR RIGHT OF WAY/PROPERTY LINE/EASEMENT TAPPING THROUGH POLYETHELENE ENCASEMENT. VALVE & VALVE BOX 2. ALL MATERIAL TO COMPLY WITH VALVE & VALVE BOX BRUNSWICK COUNTY SPECIFICATIONS. (NOT REQUIRED FOR 3. TRACER WIRE SHALL BE INSTALLED SHORT SIDE TAPS) FROM THE FORCE MAIN TO THE VALVE PAVEMENT CURB BOX. FINISHED GRADE — m 18"-24" l CONTRACTOR TO USE TAPPING SADDLE AS MANUFACTURED BY SMITH—BLAIR MODEL 317 W/316 SS STRAPS, STUDS AND NUTS, 36"-48" TYP _ OR EQUAL Polywrap (S mil) _ TAPPING SADDLE 2" CTS SERVICE TUBING 1 1/2" MUELLER 300 BALL CURB 1 1/2" VALVE NO. B-25122,013 EQUAL WITH MUELLER 110 COMPRESSION Ductile Iron CONNECTION FOR CTS TUBING or PVC Pipe 1 1/2" IPT MUELLER 300 BALL CORPORATION VALVE B-25028, OR EQUAL W/MUELLER 110 COMPRESSION CONNECTION FOR CTS TUBING. ISTANCE VARIES LOW PRESSURE SEWER CONNECTION DETAIL NTS CONCRETE METER BOX ENCLOSURE, TRAFFIC RATED, MARKED SEWER ON LID. TO BE PLACED AT RIGHT—OF—WAY LINE. i A I CAMLOCK FITTING WITH LOCKABLE CAP (SIZE SAME AS LOW PLAN VIEW PRESSURE SEWER) FORCE MAIN FLOW DIRECTION TOIN PORT VALVE BOX VIEW "A" CAMLOCK FITTING WITH LOCKABLE CAP (SIZE SAME AS LOW PRESSURE SEWER) PLUG T VALVE BOX VALVE CONCRETE PAD GRAVEL BEDDING 45' ELBOW WYE VALVE BOX & PLUG VALVE. SIZE TEE PER LOW PRESSURE MAIN 6" WASHED STONE BASE LOW PRESSURE MAIN, SEE PLAN FOR SIZES VALVE/FLUSHING CONNECTION AT INTERSECTING PIPES DETAIL NTS IMA. HDR Engineering, Inc. of the Carolinas 780-2 Chandlers Lane I Sunset Beach, NC 28648 TEE 4 I 5 I g I 7 1 1/2" SINKING BALL CHECK VALVE FEMALE IPS x IPS, MODEL 208 PART NO. 2142-0, AS MANUFACTUED BY FLOWMATIC, OR EQUAL CONTRACTOR TO INSTALL A 18"x3O" RECTANGULAR CAST IRON METER BOX ASPHALT COATED MODEL NO. MBX-5A �—PROPERTY LINE AS MANUFACTURED BY FASTECH, OR EQUAL GRINDER PUMP STATION PUMP PANEL GRAVITY LINE FROM HOUSE HOUSE PUMP DISCHARGE (FRONT) TO MAIN 5' MIN 1 1/4" X 1 1/2" ADAPTER GRINDER PUMP TANK .SLOW PRESSURE SEPTIC TAP 0 PROPERTY LINE 1 1/2" IPT MUELLER 300 BALL � PROPERTY LINE —ROAD R/W CURB VALVE B-25122, OR EQUAL — — — — — — — — — — — W/MUELLER 110 COMPRESSION CONNECTION FOR CTS TUBING W/ LEVER ACTUATOR STREET LEFT SIDE INSTALLATION (RIGHT SIDE SIMILAR) TYPICAL RESIDENTIAL GRINDER PUMP STATION LOCATION DETAIL NTS CONCRETE METER BOX ENCLOSURE, TRAFFIC RATED, MARKED SEWER ON LID. TO BE PLACED AT RIGHT—OF—WAY LINE. GRADE PLAN VIEW FORCE MAIN FLOW DIRECTION DOWNSTREAM PORT —� CENTER VALVE BOX CAMLOCK FITTING WITH LOCKABLE CAP (SIZE SAME AS LOW PRESSURE SEWER) PLUG VALVE BOX VALVE CONCRETE PAD — GRAVEL BEDDING 45' ELBOW WYE -i i CAMLOCK FITTING — WITH LOCKABLE CAP (SIZE SAME AS LOW PRESSURE SEWER) TBLOCK UPSTREAM PORT VIEW "A" Fi-CAMLOCK FITTING WITH LOCKABLE CAP (SIZE SAME AS LOW PRESSURE SEWER) —CONCRETE PAD 1 GRAVEL BEDDING 45' ELBOW r WYE vnwL. OVA « PLAN FOR SIZES PLUG VALVE. SIZE 6" WASHED PER LOW PRESSURE MAIN STONE BASE Z'LOW PRESSURE MAIN, NOTE: AT END OF LINE FLUSH CONNECTIONS, OMIT CENTER SEE PLAN FOR SIZES VALVE BOX AND DOWNSTREAM FLUSH PORT. DO NOT USE WYE CONNECTOR. INSTALL CONNECTION IN -LINE WITH LPS. IN-LINE/END OF LINE j VALVE/FLUSHING CONNECTION DETAIL NTS PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 FOR APPROVAL ISSUE DATE DESCRIPTION PROJECT NUMBER 008176-68249-01 81 o 0* tS��E ""T24 4 °1 f 2401 VG VED __.... _.. .-ORCE MAIN ELEVATION Z8."45' RJ FITTING (AS REQUIRED) 6" GRANULAR BEDDING MATERIAL al�.y,ll't ',E.iVLN --- GRAVITY SEWER OPTION 1 OPTION 2 USE GROUT TO FORM INVERT AND BENCH TO DIRECT FLOW DOWNSTREAM NOTES: 1. ALL PIPE AND FITTINGS SHALL BE DUCTILE IRON, SIZE 6 TO MATCH PROPOSED FORCE MAIN. ALL BOLTS, NUTS, AND FASTENERS SHALL BE STAINLESS STEEL. 2. PROVIDE WATERTIGHT SEAL BETWEEN MANHOLE WALL AND PIPE USING LINK —SEAL. FORCE MAIN/LOW PRESSURE SEWER CONNECTION INTO MANHOLE DETAIL NTS BRUNSWI,CI,COUNTY , ,u� ,, PUBLIC; UTILITIES CALABASH ASS WATER COLLECTION".SYST11111 EM EXPANSION 1,. r , ma BRUNSWICK COUNTY NORTH CAROLINA 1:1 PANEL BOTTOM OF PANEL TOP OF TANK ® FINAL GRADE SURFACE D FLANGE R GRAVITY AND ID FOR ESSURE 8" 90' FLANGED BASE FITTING USE GROUT TO FORM INVERT AND BENCH TO DIRECT FLOW DOWNSTREAM GRANULAR BEDDING MATERIAL STANDARD DETAILS 0 1" 2" FILENAME OOC-07.dwg SHEET SCALE AS NOTED OOC-07 D C B A 1 2 3 4 5 r I ! NEW EASEMENT (30') i II ( I NI I I I I f GRAVITY SERVICE I i I I LATERAL 7' X 11' AREA 8' GRAVITY SEWER RESERVED FOR FUTURE SEE SHEET 01C-141 FOR ODOR/ CONTROL. FOR PIPING INFORMATImN.--�1111 ` r 6' X 6' TA 6' X 10' I i GENERATOR PAD ANTENNA PAD ' AREA LIGHT I I r !' ( '; � `• W , I 16 LF 8" GRAVITY SEWE i \ T.G.C. DIP AT;'O.8% 17.F,,�, . EXISTING 8" PMH 80 1 i W FORCE MAIN I 1, ro SEE SHEET, > 01C-141 < ? I CHAIN LINK FENCE I JERVICE 8' WETWELL4" DRAINATER U } • NEW BEACH DRIVE II I ILLj Q PUMP "STATION WATER `METER a`, m o; ALL WEATHER ACESS PZ i 0 I ' '-'J 8" X 6" TAPPING I DRIVE SHOULD EXTEND i'o SLEEVE AND VALVE ' 1'-0" BEYOND FENCE. ( < i 45 LF 12.75" SCP 6' X 8' VALVE PIT 6.. FM 1 I 1 6" CONCRETE PAD - - - - - - - EMERGENCY FREEZE PRO - - - - I I. 14.00 CONNECTION YARD NT __— BORE PIT. RECEIVING a-- O'x30'x9' PIT sr sr �r I ._ t ; 9'x10'X6, 5 TYP. �I DOUBLE SWING GATES I, ! 2 0 6' l o TOTAL OPENING 12'-0"wo i ) 12' WIDE ALL WEATHER 12.00 I o 0 0 I' ACCESS DRIVE CONSTRUCTION C ENTRANCE - ._.. IMPROVE EXISTING GRAVEL. 'DRIVE TO ALL WEATHER ACCESS .DRIVE: sr — -S - -Sr-- sr �. f.- f� E' i LOW PRES -' i i I SERVICE LINE f , � I , I , ' 1 : III HUGHES LUTHER D I j ,PARCEL # 25500172, PIN # 103519616642 j Issal HDR Engineering, Inc. of the Carolinas 780-2 Chandlers lane I Sunset Beach, NC 29648 PROJECT MANAGER E. WILLIAMS, PE DESIGN ENGINEER R. PLUMMER, PE CHECKED BY K. BARRETT, PE 1 12/2008 FOR APPROVAL ISSUE DATE DESCRIPTION PROJECT NUMBER 008176-68249-01 81 ��i{ CARp�r Essi`y�ry9�'�S •' .s = r 9 4124 4 6 I 7 M. NOTE: 1. ALL PRESSURE PIPING TO BE RESTRAINED JOINT. 2. INSTALL SILT FENCE AROUND BORE PIT AND RECEIVING PIT. 3. FLOOD PLAIN ELEVATION 12.0 MSL BASED ON FIRM MAP 3720103500J. 4. BUILT UPON AREA IS 4,540 SQUARE FEET. 5. PLANT 12 WAX MYRTLES (MYRICA CERIFERA) 3 GALLON CONTAINERS, IN THE APPROXIMATE LOCATIONS SHOWN. IN NO CASE SHALL A WAX MYRTLE BE PLACED WITHIN 5' OF A WATER LINE, SEWER LINE OR SERVICE. FOLLOW INSTRUCTIONS FROM NURSERY PROVIDER FOR PLANTING INSTRUCTIONS. 0+00 0+00 BRUNSWI, PUBLIC. CALABASH , COLLECTION'�Y WICK COUNTY 10 0 10 15 HORIZONTAL SCALE: 1" = 10' CK,,COUNTY IES WASTEWATER 4.9 STENf` EXPANSION NORTH CAROLINA 2 0 2 3 VERTICAL SCALE: 1" = 2" BEACH DRIVE PUMP STATION SITE PLAN 0 1" 2" FILENAME 02D-101.dwg SHEET SCALE 1" = 10' 02D-101 D C A 6 3 I 4 I 5 I 6 7 I g fv?n , I,.,...,-, I .n. I Sun,-f 0„,n, Nr 1a949 I PROJECT NUMBER 1008176-68249-01£ NOTES: 1. ALL PRESSURE PIPING THIS SHEET TO BE DUCTILE IRON RESTRAINED JOINT. 2. 100 YEAR FLOOD ELEVATION 12 MSL FIRM MAP 3720103500J EFFECTIVE DATE JUNE 2, 2006. 3. BUILT UPON AREA FOR WILSON AVENUE PUMP STATION SITE IS 3,920 SQUARE FEET. 4. PLANT 20 WAX MYRTLES (MYRICA CERIFERA) 3 GALLON CONTAINERS, IN THE APPROXIMATE LOCATIONS SHOWN. IN NO CASE SHALL A WAX MYRTLE BE PLACED WITHIN 5' OF A WATER OR SEWER LINE OR SERVICE. FOLLOW INSTRUCTIONS FROM NURSERY PROVIDER FOR PLANTING INSTRUCTIONS. BRUNSWICKZOUNTY WILSON AVENUE PUMP STATION PUBL1 UT�1TIES SITE PLAN CALABASH ,. p►S1 EWATER COLLECTION`YSTE,IIIEXPANSION ''§"'°1" 2" FINAME 03D-101.dwgLESHEET 0 WICK COUNTY NORTH CAROLINA SCALE 1" = 10' 03D-101 IC C A