HomeMy WebLinkAboutSW8081007_APPROVED PLANS_20140630STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 0 8 10 0"1 DOC TYPE ❑ CURRENT PERMIT �I APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 20\ti4 �.D 30 YYYYMMDD C C 1 �7 E 2 3 , MATCHLINE A -A 5 K n a F C I PROJECT LIMITS -- 784,566 SF (18.01 AC) L1 C17 C14- C12� C11-\ L5- �� L3 C7\8 L CURVE TABLE Curve # LENGTH RADIUS DELTA C1 90.01, 57.00' 90-28'49" C3 107.84' 217.00' 28-28'22" C5 65.02 67.00' 55'36'05" C7 55.08' 1�17.00' 26'58119" C8 34.11' 89.00' 2 C11 I 13.04' 39.00' 19'09'18" C12 39.11' 117.00' 19'09'17" C14 17.57' 89.00' 11*18'34" C15 23.09' 1 117.00' 11 *18'34" C17 14.78' 89.00' 9'30'43" C18 19.42' , 117.00' 9-, 43" C20 58.07' 417.00' 7'58'43" -- -��- C21 194406' 1 789.00' -- !, 14'05'33" 517.00' 12'36'23" C22 113.75' C23 141.11 i 483.00' 16'44'23" C24 20.51' 117.04' 10'02'19" C28 26.51' 89.11' 1 17'02'44" - C29 149.04' 511.00 16'42'40" C30 107.59' 489.00' 12-36'23" C31 187.76' 817.00' 13'10'04" I� C28 CIA IU I� PROJECT LIMITS for SW8 120101 C36 L12 yq L13 - V25 \,� ^� 0 Jfp-- -pj -_j' i47 C104 U I;� L50 I r-_ I I\ L49 C, C105 In CURVE TABLE Curve # i LENGTH RADIUS DELTA C35 31.45' 317.00' 5'41'01" + C36 9.41' 66.04' 8-10'03" C37 C38 254.87' 19.04' 412.00' 233.00' 35'26'40" 4'40'52" C39 173.52' 817.00' 12'10'09" C40 12.14' 39,00' 17'49'41" C41 28.68 2017.00' 0-48'53" C42 124.64' 2017.00' 3-32'26" C43 13.77' 39.00' 20*13'56" C44 177.19' 2017.00' 5-02'00" C45 10.57 39.00' 15'32'01" C46 194.63' 2017.00' 5'31'43" C47 16.10' 39.00' 23-39'32" C48 21.53 1 61.00 1 20*13'33" C52 11.65' 33.00' 20*13'33" C53 27.67' ( 67.00 1 23*3932" C54 191.93' 1989.00' 5'31'43" C55 18.16' 67.00' 15'32'01" C56 174.73' 1989.00' 5-02'00" C57 23.66' 67.00' 20'13'56" ) f Q; ' C C', i e,Z4; Q) / -L2110 L23 �L24 L22 C72i C74.3 C_76 L_25 _ �L112 L110 \) \; -L26 L106 j ,o L _ _ L27 L104 1<8 C83 - C, - - MATCHLINE A -A CURVE TABLE Curve # LENGTH RADIUS DELTA C58 123.32' 1989.00' 3'33'08" C60 1 20.85' 67.00' 17'49'41" C61 167.58' 789.00' 12-10'09" C62 21.32' 261.00' 4'40'52" C63 237.60' 384.00' 35'27'05' C64 13.58' 93.97' 8'16'45" C65 98.37' 289.00' 19*30'05" C67 38.71' 186.00' 11'55'32" C69 9.54' 6.00' 91'04'19" C72 49.99' 486.00' 5'53'39" C74 55.63' C76 53.68' 214.00' 14'53'37" 286.00' 10'45'17" C78,195.63' 107.00' 104-45'18" C80 18.55' 83.00' 12'48'31" C82 16.26' 9.00' 103'29'21" C83 197.11' 517.00' 21'50'41" C84 198.63' 689.00' 16'31'02" C85 96.78' 517.00' 10*43'33" C86 91.90' 47.00' 112-02'12" C104 22.32' 89.00' 14'22'08" s- L17 C.0 84- C132 C85 CURVE TABLE Curve # LENGTH RADIUS DELTA C105 22.40' 67.00' 19'09'18" C106 42.13' 27.00' 89'24'37" C107 44.84' 117.00' 21*57'31" C108 41.90' 89.00' 26'58'19" C109 37.85' 39.00' 55'36'05" C110 93.92 189.00' 28'28'22" C111 62.55' 67.00' 53'29'12" C112 105.17' 389.00' 15'29'26" C113 141.71' 417.00' 19'28'14" C114 101.04' 117400' 49-28'52" C115 65.02' 39.00' 95'31'04" C116 103.71' 289.00' 20'33'38" C117 92.57' 317.00' 16-43'52" C118 370.74' 189.00' 112*23'30" C119 53.78' 217.00' 14*11'57" C120 52.41' 29.00' 103'32'43" C121 175.52' 117.00' 85'57'08" C122 36.13' 87.00' 23'47'43" C123 93.55' 183.00 29*17'18" C124 68.57' 817.00' 4'48'32" tV/ CURVE TABLE Curve # LENGTH RADIUS DELTA C125 177.77' 789.00' 12'54'34" C126 180.37' 1017,00' 10'09'42" C127 108.76' 789.00' 7-53'54" C128 100.82' 817.00' 7'04'13" C129 100.30' 489.00' 11'45'05" C130 37.15' 19.00' 112*02'12" C131 91.54' 489.00' 10-43'33" C132 206.70' 717.00' 16'31'C2" C133 186.44' 489.00' 21'50'41" C134 66.83' 37.00' 103'29'21" C135 24.84' 111.00' 12'49'10" C136 144.44' 79.00' 104'41'18" C137 58.94' 314.00' 10*45'! 7" C138 48.35' 186.00' 14'53'37" C139 52.88' 514400' 5'53'39" C140 54.04' 34.00' 91'04'19" C141 44.54' 214.00' 11'55'32" ! J L68� i I 2gV\ �! �Z i ! I� L43 N; / 'U LINE TABLE TAG LENGTH DIRECTION L1 279.90' N07'44'07"W L2 161.49' N20'44'15"E L3 42.71' N76'20'20"E L4 65.22' N81-21'08"E L5 1.56' N08'03'29"W L6 92.20' N08'03'29"W L7 80.97' N08'03'29"W L8 52.34' N08'03'29"W L9 4.82' N49'47'59"E L10 10.64' N32'27'00"E L11 17.64' N81'40'45"E L12 154.03' N85'12'01"E L13 123.83' N85.12'01 "E L14 108.37' S67'22'13"E L15 64.89' N15'48'30"E L16 28.00' S74'11'30"E L17 64.90' S15'48'30"W L18 27.87' S40'29'51 "W L19 146.68' SO4'06'30"W L20 63.26' S07'49'02"E LINE TABLE TAG LENGTH DIRECTION L21 12.46' N81'06'39"E L22 136.94' N81'06'39"E L23 25.34' N75*13'01"E L24 25.55' S89'53'23"E L25 58.26' N79'21'21"E L26 12.81' SO4'06'39"W L27 40.38' S08'51'03"E L28 34.74' S67'34'14"E L29 1167.92' S23'44'22"W L30 131.17' SO4'59'46"E L31 139.70' S67'11'04"E L32 525.71' S24'18'53"W L33 163.55' S50'44'33"W L34 199.03' N75'35'36"W L35 359.92' S29'23'32"W L36 112.06' N32'15'29"W L37 246.79' N11'59'41 "E L38 317.60' N72'59'27"W L39 814.91' N52'25'49"W L40 314.21' N65'19'10"E LINE TABLE TAG LENGTH DIRECTION L41 323.56' N43'05'15"E L42 70.63' 1\110'22'25"W L43 152.62' S79'37'35"W L44 166.99' N09'36'34"W L45 178.53' S81'15'45"W L46 16.49' S73'20'07"W L47 39.07' S80'38'36"W L48 132.05' S09'13'17"E L49 88.56' S80'43'39"W L50 17.31' N77'47'59"W L53 2.55' S08'03'29"E L55 66.21' S81'21'08"W L58 42.71' S76'20'20"W L60 161.49' S20'44'15"W L62 62.92' S07'44'07"E L63 279.35 N81'41'27"E L64 16.16' N64'13'31"E L65 34.22' S07'06'53"E L66 47.75' S81'50'03"W L67 228.76' S08'36'07"E LINE TABLE TAG LENGTH DIRECTION L68 69.14' S81'31'42"W L70 164.90' S10'22'25"E L74 282.10' S43'05'15"W L76 87.28' S52'25'49"E L78 3Y5.68 S72'59'27"E L80 256.34' S56'15'35"E L83 278.55' i N25'32'53"E L85 35.13' N77'59'50"W L87 70.16' N62-18'30"W L88 132.88' N06'22'57"W L89 110453' N55'26'43"E L97 196.04' N27'30'04"E L104 40.38' N08'51'03"W L106 12.86' N04'06'38"E L108 58.26' S79'21'21 "W L110 25.55' N89'53'23"W L112 25.34' S75'13'01 "W L114 139.44' S81'06'39"W L115 9.96' S81'06'39"W L117 63.26' N07'49'02"W 0 z 0 a a U 0 \\\�� CA4010 �/��iM1, �? ��SE,AL 'y y.= `� 02503 1'GINE��S0 ... (ANDALE >. SUNDT .1)OINTVEM FE "gCalib e \\ DES IDRW CHK UI «PM/DM» BRANCH MANAGER CHIEF ENG/ARCH «XX» ZUA E 0 Z > LINE TABLE TAG LENGTH DIRECTION L119 59.73' N04'06'30"E z 5¢o cos CE U W Q V V' ✓ ,�r�� G T %mil c� C ( in' {'S o � U) t-Z - ;yK U U)O z Z Z J W I- w IrO W e,PN, 410/aoia z O ,jn5t (t 4��` / /iI'•liidl` li.! (n F Q U JcW-14 e� 7 w J o Z r wLL Q w LL o LL w 2 o _I �C Q Q Q U Q z m COASTAL o Z �\ SITE SCALE: AS INDICATED DESIGN, PC EPROJECT NO.. p'I(W!C P.0. Wv 1011 CONSTR. CONTR. NO. N40085-11-C-4020 NAVFAC DRAWING NO. 0 JO 00 120 SHEET OF 541 SHEET NO. 1 inch _ 60 tL HorlaonW P L L in co Lu m C FL N CD N co co h 3 0 5 2 C C V� 41 `1 INFILTRATION BASIN 2 1.81 AC 0 INFILTRATIO BASIN 1 Uja� -_-r'- ----- ----- .81 AC n raw\� I Q�1 if if It t lot- --I, of I It r r , a� r , ,` , Jt `�♦, ,/ ` 1. + , —J� idt 11 1 , t , t +' �' , i It stIN 'fur' t t ; �-_•'_•' t / ,♦ r It e J - r 1't - t l r r ' t • 1 ist� 11 J f ' lof 1 { BARS l 1 . ROPE gpAB I 2 I-•: •',-t --- ✓�a '. mot` _-`. '"�i. } ... s , Is NT t + r r + ------------' f �i J � r � ' � I I , t , t ' r 1 .�� -1011 - - - - - - -------------- %COt LtDGE y " --c _ - r - - ! r. ` , f , , { 11 a st , -- `TAFT ROAD J _ � ` � `it :Isit ; ;,(— t 1 1 »`' t , E s_ II:_..i�� s ! 1i li_ —_ -- _ _ —_ --_ ______ ..—_'-_ ._._._._-___------..tr-.•......•_ _`{L.. _._ _ _ ...___......-______. _.__._..__ _ --.1 �,-_.•�''J_ -ti - TT 1, 1l - ; '` t rl 1� — —E _ � ���-,,. r-----r I'Y _��� _t t — -- --j I-- _ __ rt_I `•--�-'-*_ � I 1 ----- --------- col �>-I I zi CL ! i t___--___15_Ltc1 �--•�`�"•--- t�?�„--_—_—__—'' �----�--11 1j —_J t__I .. 'rcw_r y r 3 4 I , , , yo , r , :t r f . COASTAL SITE DESIGN,PC r�r„o 4(t;Im t.vo ei wac COAL t.1EC4,IMl I�PAf (fl0) AI-NII 0 30 00 12D 1 inch 80 ft Horizontal a u, 0 D NAAFAC' Q� %SEAL S L 1025'45 1 • �` li ESQ LNG+IN� 2 v. ! ANDALF •�' SUNDT '"Caltb s DES IDRW JCHK - B <,PM/DM» BRANCH MANAGER CHIEF ENG/ARCH «xx» o a z s z J ego Q v) w 0 0 cr Q LIJ L1J LL 1 > l a z z:) � � Q `.-' c� Q CL z G LtJ Q U) O z z Fr Wz 00 z _ w UQ O U m Q w = W T o Z r % J (, =ap U w w" LL LL z z q oJ a 0 z Q w K 0 Q U � `� aza o T i (6 SCALE AS INDICATED EPROJECT NO: - CONSTR. CONTR. NO N40085-1 1 -C-4020 w @ NAVFAC DRAWING NO. L N SHEET OF 541 r- O N SHEET NO. DA c I 1 2 3 iljt COMPANY TREET o O m U U 40 a i % N J\ q Y ` —... _�j LIMITS SOSF \ =I4JE \1 RI`, t= --------- aSFSUF •- ___ \ ` jS;uacuanod a p3 — _ ----1 - - - — - 6' w . i ------ mmamrrapp3 SF -50 ;uatuanod au1t�a;uao o Y'"vim s. _ ( TYP. o • w � N . � '4* :ftft +B site, -^- III START OF GREENWAY TRAIL �t *t 0 / `c ,a SF i �%` v �. 000 CONTRACTOR TO COORDINATE �I �'o � W/ STAFF NCO ON MARKER STYLE ` e / 40* ,� - �l AND PLACEMENT GREENWAY TRAIL STA: 0+00 TO 10+00 % w N To iiiir �� ` /• NORTH C } � O \.. 11 J -- Z KEYMAP SF' � -5 , TYP - LEGEND !, C �� rJ SF CA GREENWAY TRAIL �����5...... 0 (SEE DETAIL 6e SHEET C500) `2QESSjoZ�9 SEAL- _ �;02b48 2° DETAIL REFERENCES SF '� �'� //' N CLEARING LIMITS \ o DETAIL NUMBER / / /zAL \ �, v� ��� DETAIL SHEET NUMBER � 11 (ADALE. -d�� c Ii SF a »ci+nvErcn:RE o 6e 6' WIDE PAVEMENT SECTION SUNDT � `�� PLAN KEY NOTES � J III — g ` - ENDWALL EW-40 _ HI VISIBILITY PEDESTRIAN CROSSWALK PER NCDOT STD. C�Ibeg. ` a 14+65.71 7.50' L I r l r f YIELD TO PEDESTRIAN IN WALK (R1-5A) APPROVED INV. 15.00 -'l ---� 24.02' of 15' RCP ® 4.16% I i 1 YIELD TO PEDESTRIAN IN WALK (R10-15) 6e -50 I �SF�". i / / ENDWALL EW-41 FOR COMMANDER NAVFAC ACTIVITY 14+82.38 9.81 .. NOT S Des AnsFAcroav To DATE TYP. V. 14.00 , �_�` j8 KLH DRI RLS CHK TAJ ,. �^ 1. SEE SHEET C-704 FOR EROSION CONTROL DETAILS. 2 INCLUDE MINIMUM OVERHEAD CLEARANCE '^ _ h BRANCH MANAGER no OF 10 ~ Wiz. ,\ — B -= - --------- _ - .,.- x i z au spooM SF 0 -- — SF ' a (� ' --- 14 ----- - SF U Z GREENWAY TRAIL STA: 10+00 TO 20+00 w g =Q= woo w i o a i rt r�FGCa/ a O �- 1. 1.0' 6.0' 1.0' ZQ U, co 6e � �� H SEE SHEET C500 2 W > i -50 w 1 �, k / �� d i x o 0.5 MILE POINT OF GREENWAY TRAIL �' �� 4 FOR TRAIL DETAILS p O { MTh P. � ` _ �� Et�1DWALL a �, CONTRACTOR TO COORDINATE .'� Z � � 1. 4 � � � Z EW-42 STAFF NCO ON MARKER STYLE �' Z Z ... .� 23+87.�8 1.00' L W/ ' �4: i — W 0 AND PLACEMENT W � � INV. 8.91 � '�''����� � � _" i / / t/ 4 Lu Q O _ , i Gr +a v` . W —�_� j \� R Fen f Z J CLC� mDOB, 9 F y� y40 O l , ' TYPICAL TRAIL SECTION Z = a ' .. Jt,� SF ` ��� \. $F ` W U U _ \ DEW ` wCO OP _ - - f �� t LLI i M,w EWm 43 ENDWALL ` } ak a w LL 23+80.57 11.00' R o O` /' w Q w A INV. 8.66 o- ` ` ` .14' of 15" RCP ®1.08% SF F 23- ...- ,n$ z < a � a � m � ` 6e ' f _ o a Q U (n SF SCALE: AS INDICATED TY° 000 EPROJECT NO. - i. 000 CONSTR. CONTR, NO. LJ ` f <� � v°e N40085-1 1 -C-4020 NAVFAC DRAWING NO COASTAL 12e1506e iL F o za so eo � SITE SHEET 38 OF S<, DESIGN PC Rd SHEET NO. /Z.,/ umnvxa r•Mn �J co 1 inch = 40 ft. Horizontal �" "°/ C- / D ■ M GREENWAY TRAIL STA: 20+00 TO 30+00 1 2 1 3 4 5 L4.VV VI IJ\ 1\Vr W V.VV/o COMPANY STREETS \ EfVDWA _L EW- � INV. 8.00 r r i � A F - ter -~ i � f '•:. / I --- SF } / Z . o -50 TYP., ............... ............ . i Woods Lrne 61 EW-46 ENDWALL ENDWALL EW-44 - SF % 37+80.09 11.00' L ' SF r / 32+56.60 II.00' L 28.0' INV. 7.04Y' 0 CLEARING LIMITS --_ d, INV. 7.00 --�� � j`----------------- ~- -- ,r i 6eS F Q -50 wool TYPwoo. '�`•- v 111111� -\\\ NORTH w v 9 0\ / �I ENDWALL 'l_`� EW-47 ' 37+91.14 /11.00'^R- YMAP _ - woo-" r r - �p 28.23' of 15" RCP ®0.18% s INV_ 6.8$ woo Homo Inp' < C� \ SF'.'ds r ~` ENDWALL EW-45 i ________________ _24.61 of 15" RCP ® 0.50% 32+38.92 11.00' R----.-s.--.e-x==�___----- LEGEND _ =� - „-_� -:- F -'^` ,''' INV. 6.95 i ; IS GREENWAY TRAIL CgARpliii (SEE DETAIL 6e SHEET C500) ��� �F�7S/0 `!,P'� SEAL 9 : r d r r --- _ ; DETAIL REFERENCES 021111483r ReG 7------ ,4 NE��Sa��:4<�N2 DETAIL NUMBER SEAL DETAIL SHEET NUMBER AND.�LE 6e 6' WIDE PAVEMENT SECTION -_'( SUNDT GREENWAY TRAIL STA: 30+00 TO 41+00 .NENFE PLAN KEY NOTES: i HI -VISIBILITY PEDESTRIAN CROSSWALK PER NCDOT STD. 119dCdlibe PULL-UP STATION gee �'"® YIELD TO PEDESTRIAN IN WALK (R1-5A) J.......I t 162 APPROVED PUSH-UP �~ µ-me:- 9�rta� ��� YIELD TO PEDESTRIAN IN WALK (R10-15) STATION ' ` w'i'^w•'''� 6- FOR COMMANDER NAVFAC w w�.',' O/ '�A. 'Q �r0 ACTIVITY SIT-UP 1 ? STATION ��%�`ry w +--- A� i --,--} NOTES SATISFACTORY TO DATE - i �� I I �k 1 DES KLH DRw RLS cHI< TAJ 1. SEE SHEET C-704 FOR EROSION CONTROL DETAILS. «PMlDM>' BRANCH MANAGER 2. CLEARING FOR TRAIL SHALL INCLUDE MINIMUM -- �`� OVERHEAD CLEARANCE OF 10'. CHIEF ENG/ARCH EW-50 ENDWAL=" / , `, i' f i "r""''-'! 3. FITNESS EQUIPMENT SHOWN IS INTENDED TO i U 46+73.41 11.00' L �./`e 12 28.0 oq INV. 9.9 I S 'n ' CLEARING LIMITS4 4 ; BE GENERAL IN NATURE AND SHALL BE o Z 2 yr 8.. 0, %�°Dd ``''J `��� j FINALIZED BY THE CONTRACTOR WITH THE ' r \ ` �T , / SUBMITTAL OF SHOP DRAWINGS. o 6Q- w w PQ �T ' / 4. PROVIDE A FLAT PLATFORM FOR PUSH-UP " Q U) STATION. MINIMUM SIZE OF 4 X8 . - w 0 W 20 H A_- '- 0 20 40 80 T z OPa � � 0) I I - 22.00' of 15" RCP ® 0.23% 1.0' 6.0' 1.0' ZZ 0 co J SF w II ENDWALL 1 inch = 40 ft. Horizontal SEE SHEET C500 0 - i 46+73.60 11.00R o}Y EW-51 FOR TRAIL DETAILS z f- INV. 9.92 ��4. q•1�� U CA Z zZ LU SF = Z \\ z 0 O W t CL LLJ ` TYPICAL TRAIL SECTION W Q 0 ENDWALL w' \\ 6e Q 40+86.79 11.0 LEW-48 U I�--22.00' off 15" RCP ® 0.00% (� - - -�a..� TYP. �� 1' ROUND Q U 0 w LL A ' SF -. CLEARING LIMITS o` ' STOCK BRACE o U- N a LL z a P SF \ > , 4x4 POST Q o a 2 Q w m 2x4x18• STEP SIT-UP BOARD AINDICATED ' ^ E ROJECTO.IND >' SIT-UP BOARD CONSTR. CONTR. NO. SUPPORT p W 0 I I ENDWALL - - EW-49 NAVFAC N4DRAWING 0085No.1 C 4020 c 40+86.79 1'1.00' INV. 8.00 / o °F T `•ii 'f r�11 ff� ':`'y7 t s> :-3�?:;7 4�.>��";'^ .- `. I. I.,, I I _ COASTAL 12615067 l.L r l�ii ITI, - - , SITE " y., 1--T-' T . SHEET 39 OF 541 'i•",al DESIGN,PC CD p va e.. an SHEET NO. N GREENWAY TRAIL STA: 41 +00 TO 52+00 PULL-UP STATION SIT-UP STATION ° C-702 2 3 4 5 1 2 3 4 5 COMPANYST EETB a if O a Op ` '' 0 t � f � f � ! o i N j +O � ?� .dam i yo \ o,,.`.:s / Z o i e w 1 � o i f e'r •� I � 28.0' CLEARING LIMITS / 1.0 MILE POINT OF GREENWAY TRAILS--_ ----- CONTRACTOR TO COORDINATE W/ STAFF NCO ON MARKER STYLE 5o r `f' ` �, 00 �► - AND PLACEMENT 11III'r J T�� /./• NORTH YP. r + Edge Woads t________., 1' �- 7... .._..-.. ....... ........... ..... .. ,�. _ __ ._ —. — ' MAP J -.........-0.............. ✓� r`. Y V .... t .. _._...-__._ ._._._.... . >'....... .. -. ,�` .......... ......... ....._. .. 5� ewertrne — ` r..A _.'s;_. - ...... ..,,_ ........�......_ _ ` fiaA >� i p ^4 —� ` — 1 i F� LEGEND ................._.... .. ®i qr (• �✓i n� , \ \ ;, ! a` ?y 28.D jhomCLEARING LIMES GREENWAY TRAIL \��� � {CA'RO/// , �o (SEE DETAIL 6e SHEET C500)FS3�0 _ . SEAL r : 025483 r _ DETAIL REFERENCES = '� DETAIL NUMBER ��? DETAIL SHEET NUMBER A1vDALE ' 6e 6' WIDE PAVEMENT SECTION SUNDT `-AJ01NTWIWL,RE GREENWAY TRAIL STA: 52+00 TO 63+00 PLAN KEY NOTES 4. HI -VISIBILITY PEDESTRIAN CROSSWALK PER NCDOT STD. mgACalibe �ON YIELD TO PEDESTRIAN IN WALK (R1-5A) YAPPROVED N YIELD TO PEDESTRIAN IN WALK (R10-15) FOR COMMANDER NAVFAC ACTIVITY NOTES SATISFACTORY TO DATE I DES KLH DRw RLS CHK TAJ I � 1. SEE SHEET C-704 FOR EROSION CONTROL DETAILS. «PM/DM>' BRANCH MANAGER \ \ ' � 2. INCLUDE MINIMUM s o a6 �� ..... ,,,�,...... �� I I on I OVERHEAD CLEARANCE OF t0. 1i 3 .......a B 0 20 �o eo CLEARING FOR TRAIL CHIEF EN ARCH �. Im, OWN � xx» Owl '$ 1 inch = 40 ft. Horizontal a _ m °o > d� .o..W... t z o spoo/J a6p3 f' �� A `..,,1 �1 I w i Z -4 `� A L� r i m w 0 6e i W r h -50 �; ! o cr TYP. z Q 0) J 1.0 6.0 1.0 Q d 01-1 SF r F-- !i J SEE SHEET C500 2 � 0 FOR TRAIL DETAILS O Z Q sod a la ENDWALL oi) eF 1, �_ — - — 4:�� �4 1 W = W �" 71+80 11.8 a0`� 5P 3 �4 INV. 1 8 w Z -J (� 7uaul0nod 91L1/u9000 _ 3 _ ---" — -- _ _ ��_ —� ___ _ TYPICAL TRAIL SECTION Z W < _ -----_ ivawaADd a P3--- --- ` _ `` I ----` --- W U ` SSp -W CO t u _ ------------------ - �- - ---- - - - - - ................. . SF P w 72+79.03 11.00' L EW-54 w Q w W A JOYy LL o o- o\ , I INV. 15.02 o -j w g so9; �/ to II 22.23' of 15" RCP ® 0.54% ° C) a) 28.0' 38.90' of 15" RCP ® 0.46% a w m CLEARING LIMITS ✓ I ENDWALL EW-55 rx w Z ENDWALL i 72+82.84 11.00' R m EW-52 it I I �i INV. 14.90 SCALE: AS INDICATED J) 72+08.02 15.11' R . > INV. 14.86 EPRDJECT NO.: > CONSTR.CONTR. NO. (6 1 ! b N40085-1 1 -C-4020 w 70- i (gyp f ��. COASTAL NAVFAC DRAWING NO. SITE 12615068 IL DESIGN, PC SHEET 40 OF 541 r �..a. ,N, o (NO) W SHEET NO. N GREENWAY TRAIL STA: 63+00 TO 73+00 C-703 co 1 2 3 4 5 X C nor. A COMPANY ST EET B u ENDWALL 76+73.26 ENDWALL 10.53 L. 7 56.84 15.07 k INV. 11.97 \\ ` '\\` ° ° o INV. 13.0. \ -! ; 8 of 18" RCP ®0.37% r� .\\._ �` // j / vvv`` SF vw 7 e, '�/ �� - ---- \ r - - 7 y.-- ' ..a ►w - CLEAfjING LIMITS Ai 6.• \ 40 ;rF C� 50 TYP. -` •.� '' A �/ z c��S, , 000' 1.5 MILE POINT OF GREENWAY TRAIL \ ` SF `. 0100 �� 244.81' of 15 RCP ® 0.16% CONTRACTOR TO COORDINATE %`~.\` \_ _ . �\ yAiC�/tiF \\ (7ee� 4" ' r W/ STAFF NCO ` . UCC 004 ON MARKER STYLE AND PLACEMENT r � rI i • ' /// �� � � "�""' � �► / ,�� ,-� i �' / END OF LIMITS OF DISTURBANCE COVERED UNDER JOGGING TRAILIT v' UGC v P ,P BEING APPL9S E2Z V � ✓% �� F°�e �IV D<� � � � ENDWALL C � 41y 2.77R INV 13.40 L' START LIMITS OF DISTURBANCE L_-� (/�) Y( 1 111111' l / COVERED UNDER ONSLO-2012-079 \> > �_ FM__-'_._ _ NORTH GREENWAY TRAIL STA: 73+00 TO 82+00 - .vvv��� - - - „ KEYMAP �. 4 , GA NAVFAC V3 `Ypp��+ LEGEND Y GREENWAY TRAIL ,\CARO'%// ���y ,S t\ 11 //l !j r / !/` ,ir '��''� I % �K� i / 11 /`, `.-- Il..- i ...... _-_ . C.� (SEE DETAIL 6e SHEET C500) � `( W,, O�• �'•'9 qr SEAL — ti`,f Q .' / , FINJS`H OF GREEN,V�/A TRAIL ._ DETAIL REFERENCES -'y F' FQ CONTRACTOR TO 00 DINATF�% G� o�y% ` s p.,GINE��c���`/� ,wl STOF NQU ON MARKE STYLE ; X1y t DETAIL NUMBER jND PLACEMENT i EW-19 ' EIBE ( � DETAIL SHEET NUMBER \ ��t� tiGC�,�- UGC i t SF l } - V N ANPALE c� t qS �r Y Ej 5.00' of 24„ RCP ® 0.40%/' ter . �� ,v `- 6e 6 WIDE PAVEMENT SECTION SU�IDT C F S \ rx• r i SEE PROFILE C-301 °'. NrVFNR.PE ' L� �cc \\ �i- V `C r I 3� V t I i / / ...---' ''...-i •.---^ a SF .! �.° li S PLAN KEY NOTES r UGC "_ \Occ` �_ = .' r - `J -� -Y - - HI -VISIBILITY PEDESTRIAN CROSSWALK PER NCDOT STD. ima re '. OM 6Y- \ \ GC .:,.. J X.```` .. �r� a YIELD TO PEDESTRIAN IN WALK (R1-5A) V►dlIb APPROVED = .. SF --_- 1�.= ' . ...-1 / n _ ` -J,._ '... i... \t _ ,, 6e < _ .: y S -- G l�' 50 OU YIELD TO PEDESTRIAN IN WALK 10 1 'atr�� v, ' �..... , FOR COMMANDER NAVFAC ACTIVITY .. TYP �...1 -�'" �; "\\ r,' ` � S \ , \ l.. ---- 4 G A5 " _ _ i ''� �h _ � �. �}... ...../�/ � (i _.` \ m NOTES SATISFACTORY TO DATE , py . O ASPHALT /f-� _ --- I.''... .. �'` (• t\1 �e t ' -.. it 00 DES DRW RLS CHK TAJ «PM,DM-- }.Q��. % C ' Cq E �\ L y t/545� 1. SEE SHEET C-704 FOR EROSION CONTROL DETAILS. N FOR TRAIL SHALL INC 2. INCLUDE MINIMUM BRANCH MANAGER cHiEFENcrARCH 1 ii �' s � � Tj��F � C x i J OVERHEAD CLEARANCE OF 10 _ 4 tj UAJ�. -.- �/p n A� `\ "". 1 .. i /!t.�. i ///' \ i i �i 1 Y /Cl 4._~ ,.-.�.._ _.._.4 '9 \ f ! % �i ili ! / `\ `��"� �� a'' s < r_1 z < g v •✓�,(� Q�� /�/'�/ 1 '{y `"\ \\ /�ii\ `7 w., y ^ S C!l 0 20 /O 80 w Z Y 7 gg®®`/ Cy` �•'•.:1� _ _ 4 �/ GREENWAY TRAIL STA: 82+00 TO END �go Q 1 inch = 40 ft Horizontal N o Cn w < W 1 a � 4 La 1 1 1.0' 6.0' 1.0' Z ZZ U' J 8 F T. ON CENTER LAY SOD IN A STAGGERED PATTERN WITH o 6!5o 0 o o�ypocoiocAio REFERENCE EROSION CONTROL SEE SHEET C500 r d • • • • STRIPS BUTTED TIGHTLY AGAINST EACH OTHER. CALCULATIONS FOR SPECIFIC ��°,���°< C F S OR TRAIL DETAIL 0 I— Z Q • . A SHARPENED MASON'S TROWEL BE U 0 • USED T TUCK DOWN THE ENDS AND T PIECES °000 I ONS. METER DIMENSI OUTLET PIPE DIAMETER 4, 4 ' CQ O COMPACTED FILL OR ....:::.... ... •' (Do) `' Z Z Z Z GRAVEL EXTENSION OF FABRIC AND WIRE STEEL POST d50 = REFERENCE EROSION CONTROL CALCULATIONS 4:1� �4 1 �' W LLI = cr 0 W W INTO THE TRENCH NOTE: SEE NARRATIVE GIMAX = REFERENCE EROSION CONTROL CALCULATIONS w Z 0 0 FOR MORE DETAIL. • •••••� ••�••••• MIN. =REFERENCE EROSION CONTROL CALCULATIONS N. APRON THICKNESSW = 4.5" (j LI d � ISOMETRIC VIEW FILTER TYPICAL TRAIL SECTION Z = Q FILTER EXTENSION OF FABRIC CORRECT BUTTING - ANGLED ENDS CAUSED BY THE AUTOMATIC NOTE: GEOTEX NONWOVEN FILTER FABRIC TO ILL!0 V) ( ) FABRIC AND WIRE SOD CUTTING MUST BE MATCH CORRECTLY. BE PLACED UNDER ALL STONE W CO BNIMUMS° L INTO THE TRENCH �_� INCORRECT OUTLET PROTECTION. < z ,..- w THICK LAYER OF GRAVEL \� COMPACTED RIP RAP DIMENSIONS -� 0 a (� u Z T w } FILL - ROLL SOD IMMEDIATELY TO ACHIEVE FIRM CONTACT WITH THE SOIL LL 8"MINIMUM 8"MINIMUM - HATER TO A DEPTH OF 4" AS SOON AS THE SOD IS LAID, AND CULVERT L X W X D CLASS QUANITY w rc J V-TRENCH CONTINUE WATERING AS NEEDED. - NOW WHEN SOD IS ESTABLISHED (2-3 WKS). SET MOWER HEIGHT (2-3 ). EW-40-41 9' X 6' X 1' /I 2 CY 9' X 6' 2 o _I y w Q t a a 4"MINIMUM - FOR SODDED WATERWAYS EW-42-43 X 1' // CY g 0 14"MINIMUM c LAY SOD PERPENDICULAR TO DIRECTION OF FLOW EW-44-45 9' X 6' X 1' // 2 CY w a Q m ca SECTION SECTION t USE PEGS OR STABLES TO FASTEN SOD FIRMLY AT THE ENDS OF STRIPS EW-46-47 9' X 6' X 1' ll 2 CY o Z SF SEDIMENT FENCE ( SILT FENCE AND IN THE CENTER, OR EVERY 3-4' IF THE STRIPS ARE LONG. IN CRITICAL AREAS, SECURE SOD WITH NETTING AND STAPLES. EW-48-49 9' X 6' X 1' It 2 CY SCALE: AS INDICATED Practice 6.62 TYPICAL SOD INSTALLATION EW-50-51 9' X 6' X ,' // 2 CY NTS Practice 6.12.5 EW-52-53 9' X 6' X 1' // 2 CY CONSTR. ONSTEPROJ.CONT coNN40085-11-C-4020 NTS EN-54-55 9' X 6' X 1' ll 2 CY EW-56-57 9' X 6' X 1' ll 2 CY - COASTAL NAVFAC DRAWING NO. 12615069 OUTLET PROTECTION DETAIL •', ',•. SITE DESIGN,PC SHEET 41 OF 541 SHEET NO. C-704 NOT TO SCALE „' uaftnx° vn e. qa REVISIONS SYM DESCRIPTION I DATE I APPROVED c rn =,t CD N N NEW TREE LINE & 5' / 24' / LEVEL SPREADER PROPOSED INFILTRATION BASIN'S' REUSE EXISTING CONDUCTOR OR ' SPLICE NEW CONDUCTOR AS REQUIREQ % 18' o � ' mI �j \ NEW 3/8" GUY (TYPICAL FOR 3) 2 4' 09 e: 207' 171' LIMIT OF DISTURBANCE N' 1 it � ;i Me P ELOCATE IRE HYDRANT _ �- �EVfl40 ELAS�5 TREATED WOOD POLE WITH ALL NECESSARY HARDWARE (TYPICAL FOR 3) N Ln r W co o m n ;I ! N N 7i i M N N u II I II I I i I I I , I i I i I I � I - I I I I I - ' - I r-- I �- , I I• I I , I I - - .. I I I 1 i l I I I COMPANY" STREET W - 24' 4, g _24' as / 204 NOTES FOR ELECTRICAL LINE RELOCATION' 1. REMOVE TWO EXISTING POLES IN PROPOSED PARKING LOT. 2. REUSE EXISTING CONDUCTOR. SPLICE IN NEW CONDUCTOR AS NEEDED OR AS DIRECTED BY THE CONTRACTING OFFICER. 3. CONTRACTOR MUST FURNISH AND INSTALL ALL MISCELLANEOUS ITEMS REQUIRED FOR A COMPLETE RELOCATION. N 358528.83 E 2476384.05 mm �v o� R=10' —I— NOTE: ALL RADII ARE 3' UNLESS OTHERWISE NOTED 3lj -7vN 40' 1"=40' REVISIONS SYM DESCRIPTION I DATE I APPROVED I 81 18 ROCK INLET SEDIMENT TRAP ---s- TDB TEMPORARY DIVERSION in TEMPORARY SILT FENCE III TEMPORARY ROCK SEDIMENT DAM TEMPORARY ROCK SILT CHECK TEMPORARY CONSTRUCTION ENTRANCE ® PROPOSED INFILTRATION BASIN -- — PERMANENT DRAINAGE SWALE ELEV. PROPOSED SPOT ELEVATION x U ROCK INLET SEDIMENT TRAP 2' BASE SWALE W/ 4:1 SIDES `.. IINEW/1AOSVMATTING I 41 0� z z ED ` of 15 6.5 _. r� i v 7, 0 0 c� I OgSTAc� OoURSE -. RELOCATE __ •_ -- .�' �� FIRE HYDRANT � -- � -_ —'--�- 1 .54 i 7904 y G I — •-' ; ; ' . r H _ Zoe Lm-W --- r r- Ln n z ° � , IA N F N N ? W ....N N lu: O 03 II I I I i I I I I I I I I y II 701 Corporate Center Drive EARTH TECH I AECOM Ralleegh 5NC 27607 4 919-654-6200 DEPARTMENT OF THE NAVY NAVAL FACUTIES ENGINEERING COMMAND MARINE CORPS BASE DES. B R PEASE DR. B R PEASE CHK. NJ DEAN 1"'0H CARp4/�.,' dE5 + :oF5QN SUBMITTED BY: DESIGN DIR. Q2 9<'• APPROVED: PWO OR OICC = SEAL _ = I A264S3 = i --•rcl ryt; •-� ,YFIL j , •OEP.`SATISFACTORY TO: CAMP LEJEUNE, NORTH CAROLINA M200 AREA PARKING PARKING LOT B GRADING, DRAINAGE, AND EROSION CONTROL DATE SIZE CODE (DENT. NO NAVV60002294 FAC DRAWING NO. � 80091 CONST.CONTR.N 0002 0085-08-B-0156 DATE SCALE: 1"=4U' SPEC. 05-OS-0156 SHEET 7 OF 11 SYM DESCRIPTION DATE BASIN TOP ELEVATION Final SEE TABLE SEE INFILTRATION BASIN TABLE FOR BOTTOM ELEVATION INFILTRATION N.T.S. BASIN TOP ELEVATION SECTION Final Grade OUTLET SIDE OF BASIN DIRECTION OF INFLOW BASIN SURFACE AREA AT INVERT (SF) SHWT * ELEV. (ft) BASIN INVERT ELEV. (ft) DESIGN STORAGE ELEV. (ft) BASIN BERM ELEVATION (ft) STORAGE VOLUME (cf) STORAGE DEPTH (ft) 6,490 11.50 13.70 14.70 16.00 7,015 1.00 * SHWT = Seasonal High Water Table /I ee.s;n 4 f r 2 weJ � 1 tS pP.�(% 5ju sw (11r)4) INFILTRATION BASIN TABLE LEVEL SPREADER WITH NO BYPASS OVERFLOW A qq BYPASS a� T m LEVEL SPREADER SECTION -AA WALL LEVEL SPREADER Permanant Soil Reinforcement Mat NATURAL GROUND (PSRM) T s 1.0 Erin.�o/p 2' ZVx. 6 Reinf. Conc.Wall IF--4' min. (Or 8" Block Wall) 5. 6 Conc.Footing 1.5 05 N.T.S. ER ----�2- Bypass Elevations Basin # A B (Z) A: Invert In (ft) 15.60 15.00 B: Invert. Out to Basin (ft) 15,M 14.20 C: Weir Crest Elevation (ft) 44-.70— D: Bypass Flow Outlet Invert (ft) 14.00 14.00 COASTAL SITE DESIGN,PC ttuuun,u / v[scwnu (viol no-,ui OQESBY� Q SEAL a 025483 �GI NE�� FLOW - SPUTTER TOP; 14 0 re woe f vC= � a -A ..a 15.5 14.8 REVISIONS �1 REVISED ELEVATIONS FOR ITEM C: 06101106 REV. NO. REMARKS DATE NOT A CERTIFIED DOCUMENT AS TO THE ORIGINAL DOCUMENT BUT ONLY AS TO THE REW90NS - THIS DOCUMENT ORIGINALLY ISSUED AND SEALED BY NEIL J. DEAN, PE, LICENSE NO. 026453, ON 12111108. THIS DOCUMENT IS ONLY CERTIFED AS TO THE RENSIONS. T11 TIT 43" MIN. OVERFLOW CONCRETE SLAB DESIGNED EXPECTED LOADING OPENING .. �-_ ' ELEVATION V PRIMARY OUTLET APPLY GROUT TO OBTAIN ELEVATION'S' C B FLOW ::. ; - SPUTTER • VARIABLE r-o" TYR Ir MINIMUM 3000 P.S.I. CONCRETE ELEVATION W TOP SLAB THE OVERFLOW OUTLET MAY BE LOCATED AT THE TOP OF THE FIRST COURSE OF BRICVJBLOCK BELOW THE PRIMARY OUTLET. ON PRECAST BOXES, USE 2" BELOW ELEVATION'S' DETAIL OF OVERFLOW OUTLET N.T.S. ISOMETRIC VIEW FLOVV SPLITTER BOX TOP SLAB SECTION A -A IAN GROUT INLET rTO TIE TO FLOW SPUTTER SECTION B-B - INLET SECTION C-C PRIMARY OUTLET DIRECTION OF PRIMARY OUTFLOW (TO BASIN) OPENING TOP SLAB PRIMARY OUTLET ELEVATION'S APPLY GROUT AS REQUIRED TO OBTAIN OULU ELEVATION DEC 1 � 2008 701 Corporate Center Drive SuitEARTH TECH AECOM Raleigh, NC 27607 919-654-6200 C�8 000F7W.,w tAVALFAWMEMNEMMCOMMAM DES. B M DICK DR. N J DEAN ���•""'"",,,, CHIC B M DICK �•.••o�cN CARo4Yy.,�� •s s i • -, o SUBMITTED BY: .4 4.7 DESIGN DIP. ;ci <: SEAL APPROVED: PWO OR OICC j / 02603 z _ ,/,'FC.1i11`,Z�+,�O� SATISFACTORY TO: MARINE CORPS BASE NORTH CAROLINA M200 AREA PARKING STORMWATER PLANS INFILTRATION BASIN AND FLOW SPUTTER DETAILS JDATE SIZE CODE (DENT. NO NAVFAC DRAWING NO. 80091 60002298 CONST.CONTR.NO. N40086-08-B-0156 SCALE: NITS SPEC. 06-08-0156 SHEET 11 OF 11 REVISIONS SYM DESCRIPTION I DATE JAPPROVED , ` 41. a: ' — O , '[f .r , t (I t WETLANDS Sl a I, , / NCE s '< / ITS OF DISTURB �. ARKINGAREA'A' , 1-0/ V % r` r P , 1 O L X PROJECT LIMITS. ro\ r , a: t / , - t EXISTING PARKING \ , I a �—JBM ON FLANGE • TO BE RESURFACED �llt' Il / AND RESTRIPED "L,IM,ITS OF DISTURBANCE r A 1 1 vvv�1 �l PROJECT LIMITS _ �/ / I - f I PARKING AREA B:<COCA// I lit I/ / I r. I 4z: __ {{ , w { TEN ON FLANGE BOLT\ ELEV— IB.73' , , I ', ! `,.. _. . ... ,, .. _' !; r ..' :ems '.__-. I .- � '`-. •"\ \\ r4"},, r , 1 i \ ,_ ,.. +, /', / 6' / NO VNRTCINd�S VkIITHINrPR�JFsCT LIMITSe j[ HC'Hp'l z� , I t \ t CHIN B4_NS �l � ♦r \` r � i if \ / / ROPE CLIVB �'. �� / ••�,/ � i` lI �� /l I/ 1 .11 r—: 1 r tihl it ., • ; .g_. ! ..... _ _.. -.,' .,,. ', - - ' � ! ,'I _ � !i 1, l it / O O N N 701 Corporate Center Drive SuitEARTH TECH AECOM Raleigh NC 27607 919-854-6200 DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. B R PEASE DR. B R PEASE CHIC NJ DEAN IA CAR01 ''.. iN a SUBMITTED BY: DESIGN DIR. APPROVED: PWO OR OICC SEAL E 1 A, t/ = I It j IDni�A31 b16 SAIIWtAUIUKT IU ' ' M200 AREA PARKING EXISTING CONDITIONS DATE SIZE CODE IDENT. NO NAVV60002289 FAC DRAWING NO. 80091 CONST.CONTR.N 0002 0085-08-13-0156 DATE SCALE: 1"=80' 1 SPEC. 05-08-01556 SHEET 2 OF 11 REVISIONS SYM DESCRIPTION DATE JAPPROVED i w / w w, r , i , : x o w , , a , { , -gin, ww (5--____ — , WETLANDS , , PROPP�ED INFILTRATION BASIN A ,>, `, �`, 91 --- - , 0. r _ - , ' r I I i ' - LIMITS OF TU NC T, z, v J�� '• s.,.16' w R• ARKING- REA A:- ' ww= � A / / w , rw w 146 All ' a' cl r ^ r - - PROJECT LIWTS / : w, DRAINAGE,,AREA w, If _ - , ,7 w w e a / A (P. _ ' _ / a w , , w. e 6` _ , -, „�� 1 , / ✓ Y r .. :2_-- e+m .__-_.___.y5_ (- \�[BM 'ON f[ANGE _ \`� ,./ tr ., it /1 ♦ ! .-_, ..�___, Yam, Ew ,19.63'I. 1 f l , —, / I / `, EXISTING PARKING E i , '�` I I/ AND R STRIPEDC LIMITS OF DISTURBANCE �+ I LIMITS ; 1 PROJECT` �w fit \ �\, ' c' / J r i PAttKING AREA'B', 4. ��� \\ GO , If , r - OA s IP ,RT ,m / / ` ¢ S. m\ F ,. 1' � a _1 I- _aw _ �•• �/ - \\ �_\ _ rn _. I " Y 3 i 4 rNr '• ,'. % �'41� t .-__ a'- I !'/9a' v��\ 'Is - \ \ 1 , w _ , / / w , n w IN x -�. Jar °I - yI, -- �,I I �h AF \ \ / - T 1 . _�'/' '~--•�.�w _ / , •L , TBM EL FLANGE 60LT\-\R �'�•� Bi-___.. - / - _ - w EL h _ , lh l , - - \Dw t l� 1 lift ' `w , � ��_._ /I // ���` �\�� : �/ -teat/ \�� °, - A t / I vv ,r TLC HI, DRAfNAGE AREA _ 1 vv `._� : _ �` HCHOR ROE / U vvyv NPR . , - .. " Nd� T T J : 1 / `I �/ J / •"w , fCHINU a / tl , /, w I . 111 _ - ._.. - tlf -,.. .. ROPE V / 1 / - _- �;. P,EtOP'�SEiS INFILTR�ITIOIV BASIN 'B'_ - �� --- �a, - , a A'. 111 p _ �.14 /,- s hl .... ' i '' c,-'/ p(_w �'' V ll ,-` •`_. / / ll` 11 l� 11 \h w: `! w ® I r. 00 N a •1 1 •1 •1 :1 r / / 6 / 701 Corporate Center Drive �/ f EARTH TECH AECOM Raleigh G NC 27607 _3 919-854-6200 / DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. B R PEASE DR. B R PEASE M200 AREA PARKING ,,, �.o�tH CARp4 "' ,, CHIC NJ DEAN SUBMITTED BY: ' ? E55 v F O' SITE OVERVIEW DESIGN DIR. _ SEAL ' 026453 _= APPROVED: PWO OR OICC DATE SIZE CODE (DENT. NO NAVFAC DRAWING NO. 60002290 80091 CONST.CONTR.NO. N40085-08-B-0156 • 1IN :� SATISFACTORY TO: DATE SCALE: 1"=80' 1 SPEC. 05-08-0156 SHEET 3 OF 11 �:IRIO$ REVISIONS SYM DESCRIPTION DATE JAPPROVED DO O N N 1 NEW TREE LINE N V� ---g3% 0 261' INFILTRATION BASIN'A' 315' 24' :m 171' SPREADER � LIMIT OF DISTURBANCE 36� N 358881.86 1- - I - --,\I I E 2476627.26 J �I 19 y — — — — — — — — — — — — — — — — — — — lao/ I i a�GV�A�G6 N 358862.80 E 2476687.31 �P I N 368874.06 COOLIDGE ROAD E 2476711.35 ADJUST TELEPHONE PEDESTAL a O � 1 � � OD Coo Nc� In'(��j I 11 I 2q, 24' NW._ I I i I < I I III I I 'II I I Xl1 5 /N 359 24. E 24 00 .39 9007.11 / E,2477009.53 ADJUST TELEPHONE PEDESTAL RESURFACE EXISTING PARKING AREA. PERFORM FULL DEPTH PAVEMENT REPAIR IN AREAS OF STRUCTURAL FAILURE, OR AS DIRECTED BY THE CONTRACTING OFFICER. NOTE: ALL RADII ARE 3' UNLESS OTHERWISE NOTED EARTH TECH 701 Corporate Center Drive Suit AECOM Raleigh 5NC 27607 919-854-6200 DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. B R PEASE DR. B R PEASE M200 AREA PARKING o�tH CAROB CHK. NJ DEAN _ �N ? oFESs7pN,v ` SUBMITTED BY: PARKING LOT A DESIGN DIR. :Qe '�. SITE PLAN = SEAL = 6453 _= APPROVED: PWO OR OICC DATE SIZE CODE IDENT. NO NAVFAC DRAWING NO. 60002291 NGI D 80091 NEB CONST.CONTR.NO. N40085-08-13-0156 SATISFACTORYTO: DATE "'..1.1t"', I�p13 IL`Y SCALE: 1"=40' SPEC. 05-08-0156 SHEET 4 OF 11 u REVISIONS SYM DESCRIPTION DATE I APPROVED lyyl _ r � I 'LIP ELEV - 14.00 .; WETLANI'BOUNDARY =, ? -c � LIMIT OF DISTURBANCE -y- Q----------- N----\ W D�'►� \' TD 14 — X " PROPOSED SPOT ELEVATION ROCK INLET SEDIMENT TRAP I I I _ H r j r ,I BASIN INV. Sr ELEV. = 14.40 STOP OF BERM J ELEV. 16.00 STORAGE ELEV.= 15.45 14.40 l •l u RIDGE EL. 16.20 I I I i I �I I f III 1 1 1 1"=40' 701 Corporate Center Drive EARTH TECH Suit4 AECOM C�3 Raleegh75NC 27607 919-854-6200 DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. B R PEASE DR. B R PEASE M200 AREA PARKING .•`••••,1CAR „�'''', s" °� CHK NJ DEAN SUBMITTED BY: �•?�oFESSio�'Iq � PARKING LOT A DESIGN DIR. GRADING, DRAINAGE, AND EROSION CONTROL _ SEAL = = ° 6453 _ APPROVED: PWO OR OICC DATE SIZE CODE (DENT. NO NAVFAC DRAWING NO. 60002293 %���,``G'•' "Cj D 80091 NEB' '',,NF/ CONST.CONTR.NO. N40085-08-B-0156 pEP••' "' ��''to SATISFACTORY TO: DATE SCALE: 1"=40' SPEC. 05-08-0156 SHEET 6 OF 11 t REVISIONS rYM DESCRIPTION DATE JAPPROVED 2.0" SUPERPAVE S9.5A 4'-0" SHOULDER .04 c III ICI (IIII—IIIi COMPACTED SUBGRADE - 8" AGGREGATE BASE COURSE DETAIL OF NEW ASPHALT PAVEMENT DETAIL OF EXISTING ASPHALT PAVEMENT TO BE RESURFACED ASPHALT PAVEMENT RESURFACING DETAILS OF REPAIRING EXISTING PAVEMENT PRIOR TO RESURFACING DETAIL NO 1-PAVEMENT FAILURE (SECTIONAL VIEW PAVEMENT \ENGTH & WIDTH FAILURE VARIES EXISTING PAVEMENT DETAIL NO 2-PAVEMENT REMOVAL (SECTIONAL VIEW) SAWCUT AND REMOVE LENGTH & WIDTH PAVEMENT FAILURE VARIES EXISTING PAVEMENT DETAIL NO. 2 LENGTH 8 WIDTH EXISTING ASPHALTIC PAVEMENT VARIES EXISTING BASE i— EXISTING SUBGAADE MATERIAL SAW AND REMOVE EXISTING BROKEN -UP ASPHALT PAVEMENT TO NEAT LINES AND REPLACE WITH BITUMINOUS CONCRETE SURFACE COURSE TYPE 1-2 DETAIL NO. 3 LENGTH d WIDTH VARIES I„ _ 2„ EXISTING ASPHALTIC PAVEMENT EXISTING BASE '-- EXISTING SUBGAADE MATERIAL OVERLAY PAVEMENT WITH In - 2' BITUMINOUS CONCRETE SURFACE COURSE TYPE 1-2 DETAIL NO. 4 DETAIL OF STANDARD GRASSED SWALE ( Not to Scale) Natural NaturGI Ground D �• round Min. D= 0.5 Ft. LARGE LETTER 'D' CAST INTO CENTER OF ALL COVERS APPROX. WT. - 565 LBS. HALF PLAN I' DIA. LIFT HOLE SECTION �1 MANHOLE COVER & FRAME FINISHED GRADE MANHOLE GRATE AND FRAME I' GROUT e D ° •4 AT 12' O.C. EW MIDDLE OF SLAB D D a D ROUNDED ENTRANCE W J. K Q e v D 3'-0' SOUARE ts STORM DRAIN PIPE D LSTEP ° FLOW AT D _ 16' O.C. D 6' INV ELEV OF CB IS INV D Q - 2' X 4' ELEV OF OUTLET . KEY JT. D - D 6' WATERSTOP •4 AT 12' O.C. EW •4 DOWELS TO MATCH CONTINUOUS MIDDLE OF SLAB WALL REINFORCEMENT JUNCTION BOX FOR PIPES LESS THAN 3011 N.T.S. NOTES I. DO NOT BLOCK HYDRANT DRAIN w/BLOCKING. 2. COAT TIE RODS k NUTS w/COAL TAR EPDXY. 3. DO NOT SUPPORT VALVE BOX DIRECTLY ON VALVE. It STREET V. (L VALVE — WATER MAIN 1 18' 70 6-CONC. PAD AROUND BOX I POURED -IN -PLACE TELESCOPIC POURED IN PLACE VALVE BOX CONC.BLOCK 1 60M.J. GATE VALVE TIE RODS 6' #IPE 3'MIN. LENGTH .TEE 3'-6' 1 2'-0' 1 7 CU. FT. CRUSHED STONE p;0 CONCRETE BLOCKING 2-3/4' CIE RODS BOTH SIDES OF PIPE (TYP.) TYPICAL WATERLINE & HYDRANT CROSS SECTIONS It r A SECTION B - B P THICK WELD I A MJ PL NOMINAL DIAMETER 'A' .8. TRENCH WIDTH W, REINFORCING STEEL BARS . SPACING Y, 6' 6' 12' 30' •6 12, 8' a' 12' 32' •6 12' 10' 10' 16' 34' •8 6' 12' 12' 16' 36' 08 6' IT- B V 1•V V.I.r. Ly B SECTION A - A NOTES: I. POUR CONCRETE AGAINST FIRM, UNDISTURBED SOIL. FILL AGAINST COLLAR TO BE COMPACTED TO 90Y PROCTOR FOR 6'ALONG THE PIPE ON BOTH SIDES OF THE COLLAR. 2. COMPLETELY BACKFILL AND COMPACT BEFORE PRESSURE TEST. 3. TRENCH WIDTHS ARE MAXIMUM FOR 10'EACH SIDE OF COLLAR. 4. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3,000 PSI. 5. THE THRUST COLLAR DIMENSIONS ARE BASED ON A SOIL BEARING PRESSURE OF 3,000 POUNDS PER SQUARE FOOT AND A TEST PRESSURE OF 150 PSI. THRUST COLLAR & DEAD END DETAIL EARTH TECH 701 Corporate Center Drive Suit475 AECOM Raleigh, NC 27607 919-854-6200 DEPARTMENT OF THE NAVY NAVAL FACIUTIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. DR. M200 AREA PARKING CIVIL DETAIL .'occN CAR04��., o ti •. CHIC SUBMITTED BY: DESIGN DIR. = SEAL - = // 26453 = -O�J�(/. 2� AV�vC1 NE�•P� fV( APPROVED: PWO OR OICC DATE SIZE CODE IDENT. NO 80091 NAVFAC DRAWING NO. 60002295 CONST.CONTR.NO. N40085-08-B-0156 SATISFACTORY TO: DATE SCALE: SPEC. 05-08-0156 SHEET 8 OF 11 t REVISIONS rYM DESCRIPTION DATE JAPPROVED 2.0" SUPERPAVE S9.5A 4'-0" SHOULDER .04 c III ICI (IIII—IIIi COMPACTED SUBGRADE - 8" AGGREGATE BASE COURSE DETAIL OF NEW ASPHALT PAVEMENT DETAIL OF EXISTING ASPHALT PAVEMENT TO BE RESURFACED ASPHALT PAVEMENT RESURFACING DETAILS OF REPAIRING EXISTING PAVEMENT PRIOR TO RESURFACING DETAIL NO 1-PAVEMENT FAILURE (SECTIONAL VIEW PAVEMENT \ENGTH & WIDTH FAILURE VARIES EXISTING PAVEMENT DETAIL NO 2-PAVEMENT REMOVAL (SECTIONAL VIEW) SAWCUT AND REMOVE LENGTH & WIDTH PAVEMENT FAILURE VARIES EXISTING PAVEMENT DETAIL NO. 2 LENGTH 8 WIDTH EXISTING ASPHALTIC PAVEMENT VARIES EXISTING BASE i— EXISTING SUBGAADE MATERIAL SAW AND REMOVE EXISTING BROKEN -UP ASPHALT PAVEMENT TO NEAT LINES AND REPLACE WITH BITUMINOUS CONCRETE SURFACE COURSE TYPE 1-2 DETAIL NO. 3 LENGTH d WIDTH VARIES I„ _ 2„ EXISTING ASPHALTIC PAVEMENT EXISTING BASE '-- EXISTING SUBGAADE MATERIAL OVERLAY PAVEMENT WITH In - 2' BITUMINOUS CONCRETE SURFACE COURSE TYPE 1-2 DETAIL NO. 4 DETAIL OF STANDARD GRASSED SWALE ( Not to Scale) Natural NaturGI Ground D �• round Min. D= 0.5 Ft. LARGE LETTER 'D' CAST INTO CENTER OF ALL COVERS APPROX. WT. - 565 LBS. HALF PLAN I' DIA. LIFT HOLE SECTION �1 MANHOLE COVER & FRAME FINISHED GRADE MANHOLE GRATE AND FRAME I' GROUT e D ° •4 AT 12' O.C. EW MIDDLE OF SLAB D D a D ROUNDED ENTRANCE W J. K Q e v D 3'-0' SOUARE ts STORM DRAIN PIPE D LSTEP ° FLOW AT D _ 16' O.C. D 6' INV ELEV OF CB IS INV D Q - 2' X 4' ELEV OF OUTLET . KEY JT. D - D 6' WATERSTOP •4 AT 12' O.C. EW •4 DOWELS TO MATCH CONTINUOUS MIDDLE OF SLAB WALL REINFORCEMENT JUNCTION BOX FOR PIPES LESS THAN 3011 N.T.S. NOTES I. DO NOT BLOCK HYDRANT DRAIN w/BLOCKING. 2. COAT TIE RODS k NUTS w/COAL TAR EPDXY. 3. DO NOT SUPPORT VALVE BOX DIRECTLY ON VALVE. It STREET V. (L VALVE — WATER MAIN 1 18' 70 6-CONC. PAD AROUND BOX I POURED -IN -PLACE TELESCOPIC POURED IN PLACE VALVE BOX CONC.BLOCK 1 60M.J. GATE VALVE TIE RODS 6' #IPE 3'MIN. LENGTH .TEE 3'-6' 1 2'-0' 1 7 CU. FT. CRUSHED STONE p;0 CONCRETE BLOCKING 2-3/4' CIE RODS BOTH SIDES OF PIPE (TYP.) TYPICAL WATERLINE & HYDRANT CROSS SECTIONS It r A SECTION B - B P THICK WELD I A MJ PL NOMINAL DIAMETER 'A' .8. TRENCH WIDTH W, REINFORCING STEEL BARS . SPACING Y, 6' 6' 12' 30' •6 12, 8' a' 12' 32' •6 12' 10' 10' 16' 34' •8 6' 12' 12' 16' 36' 08 6' IT- B V 1•V V.I.r. Ly B SECTION A - A NOTES: I. POUR CONCRETE AGAINST FIRM, UNDISTURBED SOIL. FILL AGAINST COLLAR TO BE COMPACTED TO 90Y PROCTOR FOR 6'ALONG THE PIPE ON BOTH SIDES OF THE COLLAR. 2. COMPLETELY BACKFILL AND COMPACT BEFORE PRESSURE TEST. 3. TRENCH WIDTHS ARE MAXIMUM FOR 10'EACH SIDE OF COLLAR. 4. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3,000 PSI. 5. THE THRUST COLLAR DIMENSIONS ARE BASED ON A SOIL BEARING PRESSURE OF 3,000 POUNDS PER SQUARE FOOT AND A TEST PRESSURE OF 150 PSI. THRUST COLLAR & DEAD END DETAIL EARTH TECH 701 Corporate Center Drive Suit475 AECOM Raleigh, NC 27607 919-854-6200 DEPARTMENT OF THE NAVY NAVAL FACIUTIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. DR. M200 AREA PARKING CIVIL DETAIL .'occN CAR04��., o ti •. CHIC SUBMITTED BY: DESIGN DIR. = SEAL - = // 26453 = -O�J�(/. 2� AV�vC1 NE�•P� fV( APPROVED: PWO OR OICC DATE SIZE CODE IDENT. NO 80091 NAVFAC DRAWING NO. 60002295 CONST.CONTR.NO. N40085-08-B-0156 SATISFACTORY TO: DATE SCALE: SPEC. 05-08-0156 SHEET 8 OF 11 PERMANENT SEEDING SEEDING AND MULCHING: REVISIONS SYM DESCRIPTION I DATE APPROVED CONTACT PERSON RESPONSIBLE FOR EROSION CONTROL MEASURES: DAVID BALOG DAVID.BALOG@USMC.MIL (E-MAIL) (910) 451-0147 (PHONE) (910) 546-4450 (CELL) NOTE: IT IS AN ONGOING REQUIREMENT DURING ALL OPERATIONS TO INSPECT ALL EROSION AND SEDIMENT CONTROL DEVICES WEEKLY ANDOR AFTER ANY RAINFALL EVENT. PERFORM REQUIRED MAINTENANCE IMMEDIATELY. SEE MAINTENANCE REQUIREMENTS BELOW FOR ADDITIONAL INFORMATION NOTES: 1. SOIL CLASSIFICATION: BmB (BAYMEADE URBAN LAND COMPLEX) 2. RECEIVING WATER COURSE: NEW RIVER CLASSIFICATION: SC; HQW; NSW 3. THE PURPOSE OF THIS PROJECT IS TO PROVIDE PARKING FACILITIES FOR THE PLANNED EXPANSION OF MCB CAMP LEJEUNE. MAINTENANCE REQUIREMENTS FOR EROSION CONTROL MEASURES 1. INSPECT SILT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SILT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REPLACE BURLAP EVERY 60 DAYS. REMOVE SEDIMIiNT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. 2. INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. 3. INSPECT, CLEAN, AND PROPERLY MAINTAIN THE ROCK INLET SEDIMENT TRAPS AFTER EVERY STORM UNTIL THE CONTRIBUTING AREA HAS BEEN PERMANENTLY STABILIZED. TO PROVIDE SATISFACTORY EFFICIENCY, REMOVE SEDIMENT FROM THE TRAPS WHEN THEY REACH ONE—HALF FULL. SPREAD ALL EXCAVATED MATERIAL EVENLY OVER THE SURROUNDING LAND AREA OR STOCKPILE AND STABILIZE APPROPRIATELY. 4. INSPECT ROCK SILT CHECKS AND CHANNELS FOR DAMAGE AFTER EACH RAIN. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT DAMAGE OCCURS BETWEEN CHECKS, INSTALL A PROTECTIVE LINER IN THAT AREA OF THE CHANNEL. REMOVE SEDIMENT ACCUMULATED BEHIND THE CHECKS TO ALLOW THE CHANNEL TO DRAIN THROUGH THE CHECK AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE CHECK. ADD STONES TO CHECKS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. 5. INSPECT ROCK SEDIMENT DAMS AFTER EACH RAINFALL. REMOVE SEDIMENT AND RESTORE ORIGINAL VOLUME WHEN SEDIMENT ACCUMULATES TO ONE— HALF OF THE DESIGN VOLUME. CHECK THE STRUCTURE FOR EROSION, PIPING, AND ROCK DISPLACEMENT AFTER EACH RAIN AND REPAIR IMMEDIATELY. REMOVE THE STRUCTURE AND ANY UNSTABLE SEDIMENT IMMEDIATELY AFTER THE CONSTRUCTION SITE HAS BEEN PERMANENTLY STABILIZED. SMOOTH THE BASIN SITE TO BLEND WITH THE SURROUNDING AREA AND STABILIZE. ALL WATER AND SEDIMENT SHOULD BE REMOVED FROM THE BASIN PRIOR TO DAM REMOVAL. SEDIMENT SHOULD BE PLACED IN DESIGNATED DISPOSAL AREAS AND NOT ALLOWED TO FLOW INTO STREAMS OR DRAJNAGEWAYS DURING STRUCTURE REMOVAL. Go 0 0 N N_ THE KINDS OF SEED AND FERTILIZER, AND THE RATES OF APPLICATION OF SEED, FERTILIZER, AND LIMESTONE, SHALL BE AS STATED BELOW. DURING PERIODS OF OVERLAPPIING DATES, THE KINDS OF SEED TO BE USED SHALL BE DETERMINED BY THE ENGINEER. ALL RATES ARE POUNDS PER ACRE. 01 MARCH THRU 31 AUGUST 01 SEPTEMBER THRU 28 FEBRUARY 50# TALL FESCUE 5# CENTIPEDE 25# BERMUDAGRASS (HULLED) 500# FERTILIZER 4000# LIMESTONE 50# TALL FESCUE 5# CENTIPEDE 35# BERMUDAGRASS (HULLED) 500# FERTILIZER 4000# LIMESTONE SLOPES 2:1 AND STEEPER AND WASTE AND BORROW LOCATIONS: 01 MARCH THRU 31 AUGUST 75# TALL FESCUE 25# BERMUDAGRASS (HULLED) 500# FERTILIZER 4000# LIMESTONE APPROVED TALL FESCUE CULTIVARS: ADVENTURE ADVENTURE 11 APACHE APACHE II BROOKSTONE BONANZA CHESAPEAKE CHIEFTAIN DEBUTANTE DUSTER FINELAWN PETITE FINELAWN GRANDE GUARDIAN JAGUAR III KENTUCKY 31 MONTAUK MUSTANG PHOENIX PIXIE REBEL JR. REBEL II SHENANDOAH TEMPO TRAILBLAZER TRIBUTE WRANGLER 01 SEPTEMBER THRU 28 FEBRUARY 75# TALL FESCUE 35# BERMUDAGRASS (HULLED) 500# FERTILIZER 4000# LIMESTONE AMIGO ANTHEM ARID AUSTIN BONANZZA II CHAPEL HILL CORONADO CROSSFIRE II FALCON FALCON II FINELAWN I GENESIS HOUNDOG JAGUAR KITTY HAWK MONARCH OLYMPIC PACER PYRAMID REBEL RENEGADE SAFARI TITAN TOMAHAWK VEGAS WOLFPACK FERTILIZER SHALL BE 10-20-20 ANALYSIS. UPON WRITTEN APPROVAL OF THE ENGINEER, A DIFFERENT ANALYSIS OF FERTILIZER MAY BE USED PROVIDED THE 1-2-2 RATIO IN MAINTAINED AND THE RATE OF APPLICATION ADJUSTED TO PROVIDE THE SAME AMOUNT OF PLANT FOOD AS THE 10-20-20 ANALYSIS. TEMPORARY SEEDING: FERTILIZER SHALL BE THE SAME ANALYSIS AS SPECIFIED FOR "SEEDING AND MULCHING" AND APPLIED AT THE RATE OF 400 POUNDS AND SEEDED AT THE RATE OF 50 POUNDS PER ACRE. SWEET SUDAN GRASS, GERMAN MILLET, OR BROWNTOP MILLET SHALL BE USED IN SUMMER MONTHS AND RYE GRAIN DURING THE REMAINDER OF THE YEAR. THE ENGINEER WILL DETERMINE THE EXACT DATES FOR USING EACH KIND OF SEED. FERTILIZER TOPDRESSING: FERTILIZER USED FOR TOPDRESSING ON ALL ROADWAY AREAS EXCEPT SLOPSE 2:1 AND STEEPER SHALL BE 10-20-20. UPON WRITTEN APPROVAL OF THE ENGINEER, A DIFFERENT ANALYSIS OF FERTILIZER MAY BE USED PROVIDED THE 1-2-2 RATIO IS MAINTAINED AND THE RATE OF APPLICATION ADJUSTED TO PROVIDE THE SAME AMOUNT OF PLANT FOOD AS A 10-20-20 ANALYSIS. FERTILIZER USED FOR TOPDRESSING ON SLOPES 2:1 AND STEEPER AND WASTE AND BORROW AREAS SHALL BE 16-8-8 GRADE AND SHALL BE APPLIED AT THE RATE OF 500 POUNDS PER ACRE. UPON WRITTEN APPROVAL OF THE ENGINEER, A DIFFERENT ANALYSIS OF FERTILIZER MAY BE USED PROVIDED THE 2-1-1 RATIO IN MAINTAINED AND THE RATE OF APPLICATION ADJUSTED TO PROVIDE THE SAME AMOUNT OF PLANT FOOD AS 16-8-8 ANALYSIS. SUPPLEMENTAL SEEDING: THE KINDS OF SEEDS AND PROPORTIONS SHALL BE THE SAME AS SPECIFIED FOR "SEEDING AND MULCHING," WITH THE .EXCEPTION THAT NO CENTIPEDE SEED WILL BE USED IN THE SEED MIX FOR SUPPLEMENTAL SEEDING. THE RATE OF APPLICATION FOR SUPPLEMENTAL SEEDING MAY VARY FROM 25# TO 75# PER ACRE. THE ACTUAL RATE PER ACRE WILL BE DETERMINED BY THE ENGINEER PRIOR TO THE TIME OF TOPDRESSING AND THE CONTRACTOR WILL BE NOTIFIED IN WRITING OF THE RATE PER ACRE, TOTAL QUANTITY NEEDED, AND THE AREAS ON WHICH TO APPLY THE SUPPLEMENTAL SEED. MINIMUM TILLAGE EQUIPMENT, CONSISTING OF A SOD SEEDER SHALL BE USED FOR INCORPORATING SEED INTO THE SOIL AS TO PREVENT DISTURBANCE OF EXISTING VEGETATION. A CLODBUSTER (BALL AND CHAIN) MAY BE USED WHERE DEGREE OF SLOPE PREVENTS THE USE OF A SOD SEEDER. MOWING: THE MINIMUM MOWING HEIGHT ON THIS PROJECT SHALL BE 4 INCHES. CRIMPING STRAW MULCH: CRIMPING WILL BE REQUIRED ON THIS PROJECT ADJACENT TO ANY SECTION OF ROADWAY WHERE TRAFFIC IS TO BE MAINTAINED OR ALLOWED DURING CONSTRUCTION. IN AREAS WITHIN 6 FEET OF THE EDGE OF PAVEMENT, STRAW IS TO BE CRIMPED AND IMMEDIATELY TACKED WITH ASPHALT TACK. TACK RATE SHALL BE 0.10 GALLONSSQUARE YARD OR 10 GALLONS PER 1000 SQUARE FEET. CRIMPING OF STRAW IN LIEU OF ASPHALT TACK WILL BE ALLOWED ON THIS PROJECT SUBJECT TO THE FOLLOWING CONDITIONS: ALL AREAS SEEDED AN MULCHED SHALL BE CRIMPED AND3'OR TACKED WITH ASPHALT AS DIRECTED BY THE ENGINEER. CRIMPING WILL BE LIMITED TO SLOPES 4:1 OR FLATTER UNLESS THE CONTRACTOR CAN DEMONSTRATE TO THE ENGINEER THAT STEEPER SLOPES CAN BE NEGOTIATED WITHOUT ALTERING THE TYPICAL SECTION. STRAW MULCH TO BE OF SUFFICIENT LENGTH AND QUALITY TO WITHSTAND THE CRIMPING OPERATION AND PROVIDE ADEQUATE GROUND COVER. CRIMPING EQUIPMENT INCLUDING POWER SOURCE SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER PROVIDING THAT THE MAXIMUM SPACING OF THE CRIMPER BLADES SHALL NOT EXCEED 8 INCHES. DISTURBED AREA 5.57 ACRES REVEGETATED AREA 2.93 ACRES CONSTRUCTION SEQUENCE 1. OBTAIN PLAN APPROVAL AND APPLICABLE PERMITS. 2. FLAG THE WORK LIMITS. 3. HOLD PRECONSTRUCTION CONFERENCE AT LEAST ONE WEEK PRIOR TO STARTING CONSTRUCTION. 4. INSTALL CONSTRUCTION ENTRANCES AND SILT FENCE AS SHOWN ON THE PLANS, OR AS DIRECTED BY THE CONTRACTING OFFICER. 5. COMPLETE SITE CLEARING AND GRUBBING. 6. INSTALL ADDITIONAL SEDIMENTATION AND EROSION CONTROL DEVICES AS REQUIRED IN THE PLANS. 7. PERFORM SITE GRADING ACTIVITIES. 8. PAVE PARKING LOTS AND CONSTRUCT INFILTRATION BASINS. SEDIMENT FROM CONSTRUCTION ACTIVITIES SHALL NOT BE PERMITTED TO ENTER THE INFILTRATION BASINS. COMPLETE FINAL GRADING OF GROUNDS AND TOPSOIL CRITICAL AREAS. PERMANENTLY VEGETATE AND MULCH THE SITE. GROUNDCOVER SHALL BE PROVIDED ON EXPOSED SLOPES WITHIN 21 CALENDAR DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. 9. ENSURE ALL SWALES AND STORMWATER INFILTRATION BASINS ARE CLEARED OF CONSTRUCTION DEBRIS AND EXCESS SEDIMENT. 10. AFTER SITE IS STABILIZED, REMOVE ALL TEMPORARY MEASURES AND INSTALL PERMANENT VEGETATION ON THE DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS OF COMPLETION OF CONSTRUCTION. 11. ESTIMATED TIME BEFORE FINAL STABILIZATION-6 MONTHS. EARTH TECH 701 Corporate Center Drive Suite AECOM Raleigh,5NC 27607 919-854-6200 DEPARTMENT OF THE NAVY NAVALFACILITIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. NJ DEAN DR. M200 AREA PARKING ` N ,A CAROB 04 SCA.. CHK. SUBMITTED BY: ;Q�� �'1°; EROSION CONTROL DETAILS DESIGN DIR. SEAL = = 026453 APPROVED: PWO OR OICC DATE SIZE CODE IDENT. NO NAVFAC DRAWING NO. _= 60002296 j�q "' � 80091 �"""Fil OF °,.`� CONST.CONTR.NO. N40085-08-13-0156 SATISFACTORY TO: DATE SCALE: SPEC. 05-08-0156 SHEET 9 OF 11 �'"' ��"'� REVISIONS SYM DESCRIPTION DATE APPROVED 0 O N N TEMPORARY ROCK SILT TEMP. STONE DITCH CHECK CVO• QPVEMESI( EDGE OF PAVEMENT ot,�6oQF. s STRUCTURAL STONE SCK LOPES ISOMETRIC VIEW 1' MIN. NATURAL GROUND CROSS SECTION VEE DITCH CHECK TYPE NOTES: STRUCTURAL STONE SHALL BE STONE FOR EROSION CONTROL CLASS "B" AND SHALL BE PAID FOR AT THE CONTRACT UNIT PRICE PER TON 'STONE FOR EROSION CONTROL CLASS "B"'. THE ENGINEER MAY DIRECT THE OPTION OF CLASS "A" STONE FOR SITES HAVING LESS THAN ONE (1) ACRE DRAINAGE AREA AND A DITCH GRADE LESS THAN 3%. PAYMENT SHALL BE UNIT PRICE PER TON 'STONE FOR EROSION CONTROL CLASS "A"' SEDIMENT CONTROL STONE SHALL BE NO. 5 OR 57 STONE AND SHALL BE PAID FOR AT THE CONTRACT UNIT PRICE PER TON "SEDIMENT CONTROL STONE" SEDIMENT CONTROL STONE SHALL BE USED AS DIRECTED BY THE ENGINEER. A g L= THE DISTANC�SUCH T POINTS A AND B ARE OF EQUAL ELEVATION CHECK DAM SPACING IN CHANNEL ewec ne nrrru ELEVATION VIEW ROCK INLET SEDIMENT TRAP TYPE 'C' 1/4" WIRE MESH pX p • .: MAXIMUM POST SPACING 4 FT. 2} SEDIMENT CONTROL C A Y 14" WIRE MESH ..•� p0 i'O tin'. NOTE 12' SEDIMENT CONTROL STONE SHALL BE NO. 5 OR NO. 57 STONE. FLOW - WIRE MESH SHALL BE mom 8' 2' WIRE HARDWARE CLOTH 23 GAUGE MIN. SEDIMENT AND SHALL HAVE 11.4 INCH MESH MESH CONTROL OPENINGS. TOP OF WIRE MESH SHALL BE A MINIMUM OF ONE FOOT BELOW THE SHOULDER OR ANY DIVERSION POINT. MAINTENANCE REQUIREMENTS: REMOVE EXCESS SEDIMENT AFTER EACH RAINFALL EVENT. Y 14" WIRE MESH NOTE FOR POST DESCRIPTION / AVERAGE BOX INSTALL WIRE MESH UNDER AVERAGE BOX v DIMENSION VARIABLE SEDIMENT CONTROL STONE. DIMENSION VARIABLE FILTERED STEEL POST SHALL BE 5 FT. FILTERED WATER IN HEIGHT, BE INSTALLED WATER SECTION A -A BE5OF THEFT.DEEP SELF-FASTENERAND SECTION Y-Y ANGLE STEEL TYPE. POST SPACING SHALL BE MULTI -DIRECTIONAL FLOW A MAXIMUM of a FT. CT ONAL FLOW ,2" SETTLED TOP 5' PROFILE SECTION STRUCTURAL STONE WEIR SINGLE -DIRE I OVERFILL 6" FOR SETTLEMENT EMERGENCY BY-PASS 6" BELOW SETTLED TOP OF DAM MAINTENANCE: `� WHEN SILT REACHES 1.5' IN DEPTH, WEIR LENGTH REMOVE IT, AND RE-FORM THE BOTTOM PLUS 5 FEET NATURAL GROUND OF THE SEDIMENT TRAP. FOR POOR DEFINED CHANNELS GROSS SECTION TEMPORARY ROCK SEDIMENT DAM, TYPE B TEMPORARY DIVERSION COMPACTED SOIL —�-� 2' MINIMUM �— :fir y.' '�::4LE-1 FLOW a:.':::'MINIMUM 6' TYPICAL CROSS SECTIONAL VIEW TOP AND BOT SHALL BE 10 TEMPORARY SILT FENCE -8' MAX. WITH WIRE +•� I I6' MAX. WITHOUT WIRE1 I MIDDLE AND VERTICAL WIRES SHALL BE 121t GAUGE MIN. WIRE) FILTER F:,BRIC� FILTER FABRIC COMPACTED FI NOTES WIRE SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE E WIRES WITH 12" STAY SPACING. FILTER FABRIC SHALL BE A MINIMUM OF 36" IN WIDTH AND SHALL BE FASTENED ADEQUATELY TO THE WIRE AS DIRECTED BY THE ENGINEER. STEEL POST SHALL BE 5'-0" IN HEIGHT AND BE OF THE SELF -FASTENER ANGLE STEEL TYPE. MAINTENANCE REQUIREMENTS: CHECK SEDIMENT FENCES AFTER EACH SIGNIFICANT RAINFALL, REMOVE THE NECESSARY SEDIMENT, AND MAKE REPAIRS PROMPTLY. POST - 2'-0" DEPTH EXTENSION OF FABRIC AND WIRE INTO TRENCH ROCK INLET SEDIMENT TRAP NOTE: USE CLASS 'A' EROSION CONTROL STON FOR STRUCTURAL STONE. USE NO. 5 OR NO. 57 STONE FOR SEDIMENT CONTROL. CONSTRUCT TOP OF BERM A MINIMUM OF ONE FOOT BELOW THE SHOULDER OR DIVERSION POINT. PROVIDE A TOTAL SEDIMENT TRAP VOLUME OF 1S003 CUBIC FEET PER ACRE OF DISTURBED AREA. SOME OF THE REQUIRED VOLUME MAY BE PROVIDED BY OTHER UP OR DOWNSTREAM CONTROLS. A SEDIMENT CONTROL Sl.,l.� DIVERSION POINT 12" MIN SEDIMENT CONTROL PLAN STRUCTURAL STONE � MrIN� SECTION A -A 6„ A JCTURAL STONE U.4 FLOW 8" PIPE MAX. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHOULDER iNOTES: I. TURNING RADIUS SUFFICIENT TO ACCOMODATE LARGE TRUCKS / SHALL BE PROVIDED. 2. ENTRANCE(S) SHOULD BE LOCATED TO PROVIDE FOR UTILIZATION SOP° \I, 110 BY ALL CONSTRUCTION VEHICLES. J� Q 'rT 3. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. i PERIODIC TOPDRESSING WITH STONE WILL BE NECESSARY. 4.ANY MATERIAL TRACKED ONTO THE ROADWAY MUST BE CLEANED UP IMMEDIATELY. 5. GRAVEL CONSTRUCTION ENTRANCE SHALL BE LOCATED AT ALL POINTS OF INGRESS AND EGRESS UNTIL SITE IS STABILIZED. FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE MUST BE PROVIDED. CLASS 'A' STONE 8 IN. MIN. DEPTH l NOTE: FILTER FABRIC TO BE PLACED BENEATH STONE EARTH TECH 701 Corporate Center DriveSuit AECOM Raleigh NC 27607 Wmm11 I 919-854-6200 DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DES. B R PEASE DR. N J DEAN M200 AREA PARKING CAROL'4' CHK. J M KAMPRATH SUBMITTED BY: ytH ESSI 4 o EROSION CONTROL DETAILS DESIGN DIR. _ SEAL _ 025453 = 44 APPROVED: PWO OR OICC DATE SIZE CODE (DENT. NO 14AVFAC DRAWING NO. 60002297 �„� Q . D 80091 N CI NEE; P� ,,:� CONST.CONTR.NO. N40085-08-B-0156 F�L 0� .`� SATISFACTORY TO: DATE SHEET 10 OF 11 SCALE: SPEC. 05-08-0156 REVISIONS SYM DESCRIPTION DATE IAPPROVED BASIN TOP ELEVATION Final Grade BASIN TOP ELEVATION Final Grade SEE TABLE OUTLET SIDE OF BASIN SEE INFILTRATION BASIN TABLE FOR BOTTOM ELEVATION INFILTRATION BASIN SECTION N.T.S. DIRECTION OF INFLOW SURFACE AREA SHWT * BASIN INVERT DESIGN STORAGE BASIN BERM STORAGE STORAGE BASIN AT INVERT (SF) ELEV. (ft) ELEV. (ft) ELEV. (ft) ELEVATION (ft) VOLUME (cf) DEPTH (ft) A 6,281 12.33 14.40 15.45 16.00 7203 1.05 B 6,490 11.50 13.70 14.70 16.00 7,015 1.00 * SHWT = Seasonal High Water Table INFILTRATION BASIN TABLE LEVEL SPREADER WITH NO BYPASS OVERFLOW BYPASS LEVEL SPREADER SECTION -AA WALL LEVEL SPREADER Pernonant Soil Renforcement Mat ,NATURAL GROUND (PSRM) I" --4' min. 2' rrpx. ' 6 Reinf. Conc.Wall ((r 8" Block Wall) �--6" Conc.Footing Bypass Elevations Basin # A B A: Invert In (ft) ' 5.60 15.0C B: Invert. Out to Basin (ft) '5.00 1420 C: Weir Crest Elevation (ft) 5.45 1470 D: Bypass Flow Outlet Invert (ft) '4.00 14.(0 FLOW - SPLITTER U CONCRETE TOP SLAB � 43°MINIMUM 43" MIN. PLAN A DIRECTION OF PRIMARY OUTFLOW (TO BASIN) No CONCRETE SLAB DESIGNED EXPECTED LOADING PRIMARY OUTLET APPLY GROUT TO OBTAIN ELEVATION'S' B C OPENING . '..•: • 6"MIN. ELEVATION 'B' OPENING B FLOW C SPLITTER VARIABLE 2'-0" TYP. 4" 4° 6" MINIMUM 3000 P.S.I. CONCRETE INLET ELEVATION 'A' DIRECTION OF 4" OVERFLOW '® 4" TOP SLAB THE OVERFLOW OUTLET MAY BE LOCATED AT THE TOP OF THE FIRST COURSE OF BRICKBLOCK BELOW THE PRIMARY OUTLET. ON PRECAST BOXES, USE T BELOW ELEVATION'B' DETAIL OF OVERFLOW OUTLET ISOMETRIC VIEW FLOW SPLITTER BOX TOP SLAB SECTION A -A 15yf 19�2" SECTION B-B - INLET GROUT INLET — TO TIE TO FLOW SPUTTER SECTION C-C PRIMARY OUTLET DIRECTION OF PRIMARY OUTFLOW (TIC BASIN) TOP SLAB PRIMARY OUTLET ELEVATION T APPLY GROUT AS REQUIRED TO OBTAIN OULET ELEVATION EARTH TECH 701 Corporate Center Drive AECOM Raleigh C NC 27607 _$ 919-854-6200 DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA DIS. B M DICK Dt. N J DEAN M200 AREA PARKING .•"""""". CIK. B M DICK SIBMITTED BY: ?�o STORMWATER PLANS _ ;Qe� �9<; INFILTRATION BASIN AND FLOW SPLITTER DETAILS DISIGN DIR. SEAL _ oz6 3 = APPROVED: PWO OR OICC DATE SIZE CODE [DENT. NO NAVFAC DRAWING NO. 60002298 ` Nci N6�• 80091 ;' •'� SATISFACTORY TO: DATE CONST.CONTR.NO. N40085-08-B-0156 SCALE: NTS SPEC. 05-08-0156 SHEET 11 OF 11 % II�Z`jt{101b