Loading...
HomeMy WebLinkAboutSW7111106_APPROVED PLANS_20201203STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT I APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE Z20 YYYYMMDD COVER SHEET FOR AMENDED FINAL PLAT OF PARKWAY SOUTH AT TANGLEWOOD -PHASE 2A CITY OF ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA SITE DATA: 1. OWNER - LOT 9: TW ELIZABETH CITY REAL ESTATE LLC 124 E. THOMPSON STREET THOMASTON, GA 30286 OWNER - LOT 10 & RESIDUAL PARCEL: TANGLEWOOD CROSSING, LLC 1108 TIDEWATER DRIVE NORFOLK, VA 23504 (757)965-8491 2. LOT 9 PARCEL NUMBER: 7993 760366; TAX MAP: P56-37 LOT 10 PARCEL NUMBER: 7993 763318; TAX MAP: P66-38 RESIDUAL PARCEL NUMBER: 7993 658737; TAX MAP: P56-3A 3. PHASE 2A & 2B - ZONED GB C( ITY - GENERAL BUSINESS) FUTURE DEVELOPMENT - ZONED C-1 (COUNTY - COMMERCIAL) THIS PROJECT IS IN THE HALSTEAD BOULEVARD EXTENSION OVERLAY DISTRICT. 4. TOTAL NUMBER OF LOTS FOR AMENDED PHASE 2A: 3 LOTS LOT 9A AREA: 1.24 ACRES LOT 9B AREA: 0.81 ACRES LOT 10 AREA: 1.58 ACRES PH. 2A RIGHT OF WAY: 0.49 ACRES FUTURE PHASE 2B: 16.61 ACRES FUTURE DEVELOPMENT: 28.47 ACRES TOTAL AREA: 49.20 ACRES LINEAR FOOTAGE OF PROPOSED STREETS IN PHASE 2A: PATRICK WAY 383 LF TOTAL 383 LF 5. THE MAINTENANCE OF THE DRAINAGE FACILITIES AND DETENTION POND IS THE RESPONSIBILITY OF THE PROPERTY OWNERS ASSOCIATION (PDA). 6. A 20' ELIZABETH CITY UTILITY EASEMENT FOR ELECTRIC, GAS, TELEPHONE, AND CABLE IS HEREBY DEDICATED ALONG ALL STREET FRONTAGES. 7. THIS SITE IS LOCATED IN FLOOD ZONE "X" ACCORDING TO FEMA FLOOD MAP 3720798200K, DATED DECEMBER 21, 2018. FLOOD ZONES ARE SCALED FROM F.I.R.M. FLOOD ZONES ARE SUBJECT TO CHANGE BY FEMA. 8. RECORDED REFERENCE: M.B. 55, PG. 33 & 34; M.B. 48, PG. 6; D.B. 1017, PG. 808 9. THIS SITE HAS NO WETLANDS AT TIME OF SURVEY. 10. 1/2" RE -BAR SET ON ALL LOT CORNERS UNLESS OTHERWISE NOTED. 11. MAXIMUM BUILT UPON AREA AS PER NCDENR PERMIT # SW71111 D6 IS SHOWN BELOW. THIS ALLOTTED AMOUNT INCLUDES ANY BUILT UPON AREA CONSTRUCTED WITHIN THE LOTS PROPERTY LINES AND THE PORTION OF THE RIGHT-OF-WAY BETWEEN THE FRONT PROPERTY LINES AND THE BACK OF CURB. LOT 9A = 38,780 SF LOT 98 = 23,956 SF LOT 10 = 48,746 SF 12. DISTANCES SHOWN ARE HORIZONTAL GROUND. 13. AREAS SHOWN WERE CALCULATED BY COORDINATE METHOD. 14. HORIZONTAL DATUM IS NAVD 88. HALSTEAD 80ULEVAR D EXTENDED PLAT BOUNDARY VICINITY MAP (NOT TO SCALE) CERTIFIFICATE OF PURPOSE OF PLAT I, JASON A. MIZELLE, PLS L-4917, CERTIFY THAT THE SURVEY CREATES A SUBDIVISION OF LAND WITHIN THE AREA OF A COUNTY OR MUNICIPALITY THAT HAS AN ORDINANCE THAT REGULATES PARCELS OF LAND; CERTIFICATE OF SURVEY AND ACCURACY I, JASON A. MIZELLE, PLS, CERTIFY THAT THIS PLAT WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED DESCRIPTION RECORDED IN DEED BOOK 1017. PAGE 808,); THAT THE BOUNDARIES NOT SURVEYED ARE CLEARLY INDICATED AS DRAWN FROM INFORMATION FOUND IN MAP BOOK 48, PAGE 6; THAT THE RATIO OF PRECISION AS CALCULATED IS 1:10,000+; THAT THIS PLAT WAS PREPARED IN ACCORDANCE WITH BOARD RULES. WITNESS MY ORIGINAL SIGNATURE, REGISTRATION NUMBER AND SEAL THIS XXTH DAY OF FEBRUARY, A.D., 2020. JASON A MIZELLE, PLSL4917 all M PHASE2B 0 FUTURE DEVELOPMENT M.B. 48, PG. 6 0000 0100 NORTH CAROLINA PASQUOTANK COUNTY I, REVIEW OFFICER FOR PASQUOTANK COUNTY, CERTIFY THAT THE MAP OR PLAT TO WHICH THIS CERTIFICATION IS AFFIXED MEETS ALL STATUTORY REQUIREMENTS FOR RECORDING. REVIEW OFFICER DATE CERTIFICATE OF FINAL APPROVAL I HEREBY CERTIFY THAT STREETS, UTILITIES AND OTHER IMPROVEMENTS HAVE BEEN INSTALLED IN AN ACCEPTABLE MANNER AND ACCORDING TO THE CITY SPECIFICATIONS IN THE SUBDIVISION DEPICTED HEREON OR THAT PERFORMANCE BOND OR OTHER SUFFICIENT SURETY IN THE AMOUNT OF N/A HAS BEEN POSTED WITH ELIZABETH CITY TO ASSURE COMPLETION OF REQUIRED IMPROVEMENTS. PLANNING DIRECTOR DATE I HEREBY CERTIFY THAT THE SUBDIVISION DEPICTED HEREON HAS BEEN GRANTED FINAL APPROVAL PURSUANT TO THE ELIZABETH CITY UNIFIED DEVELOPMENT ORDINANCE SUBJECT TO ITS BEING RECORDED IN THE OFFICE OF REGISTER OF DEEDS WITHIN SIXTY DAYS OF THE DATE BELOW. PLANNING DIREC-OR DATE DIVISION OF HIG14WAYS DISTRICT ENGINEER CERTIFICATE 1 HEREBY CERTIFY THAT THE STREETS AS DEPICTED HEREON AREIARE NOT CONSISTENT WITH THE REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. DISTRICT ENGINEER DATE VICINITY MAP (NOT TO SCALE) CERTIFICATE OF OWNERSHIP AND DEDICATION 1 (WE) HEREBY CERTIFY THAT I AM (WE ARE) THE OWNER(S) OF THE PROPERTY DESCRIBED HEREON, WHICH PROPERTY IS LOCATED WITHIN THE SUBDIVISION REGULATION JURISDICTION OF ELIZABETH CITY, THAT I (WE) HEREBY FREELY ADOPT THIS PLAN OF SUBDIVISION AND DEDICATE TO PUBLIC USE ALL AREA SHOWN ON THIS PLAT AS STREETS, ALLEYS, WALKS, PARKS, OPEN SPACE, AND EASEMENTS, EXCEPT THOSE SPECIFICALLY INDICATED AS PRIVATE, AND THAT I (WE) WILL MAINTAIN ALL SUCH AREAS UNTIL THE OFFER OF DEDICATION IS ACCEPTED BY THE APPROPRIATE PUBLIC AUTHORITY. ALL PROPERTY SHOWN ON THIS PLAT AS DEDICATED FOR A PUBLIC USE SHALL BE DEEMED TO BE DEDICATED FOR ANY OTHER PUBLIC USE AUTHORIZED BY LAW WHEN SUCH OTHER USE IS APPROVED BY THE CITY COUNCIL OF THE CITY OF ELIZABETH CITY IN THE PUBLIC INTEREST. DATE DATE NOTARY CERTIFICATE 1, 1 A NOTARY PUBLIC OF NORTH CAROLINA, DO HEREBY CERTIFY THAT COUNTY, PERSONALLY APPEARED BEFORE ME THIS DATE AND ACKNOWLEDGED THE DUE EXECUTION OF THE FOREGOING ON BEHALF OF AND AS THE ACT OF TANGLEWOOD CROSSING, LLC. WITNESS MY HAND AND OFFICIAL SEAL THIS DAY OF 202& MY COMMISSION NOTARY CERTIFICATE I, 1 A NOTARY PUBLIC OF NORTH CAROLINA, DO HEREBY CERTIFY THAT COUNTY, PERSONALLY APPEARED BEFORE ME THIS DATE AND ACKNOWLEDGED THE DUE EXECUTION OF THE FOREGOING ON BEHALF OF AND AS THE ACT OF TANGLEWOOD CROSSING, LLC. WITNESS MY HAND AND OFFICIAL SEAL THIS DAY OF 2020. MY COMMISSION p PNpENV►RONMENTAL NO D AN ONMOFEWATOERQUL� IT( DRAINAGE AND UTILITY EASEMENTS SHALL REMAIN FREE OF SUBSTANTIAL STRUCTURES AND THAT THE REPAIR TO ANY STRUCTURE OR LANDSCAPING LOCATED IN THE EASEMENTS FOLLOWING ACCESS TO THE FACILITIES BY THE CITY OR UTILITY COMPANY SHALL BE AT THE EXPENSE OF THE PROPERTY OWNER. RECEIVED EOV 30 M 7i. TANGLEWO 30 CONTROL MONUMENT 4 NC GRID NAD 83 N 936,346.4615 SFT E2,795,486.49B9 sFT --S83°3855"bV 1465_88' TIE TO BENCHMARK _ - tiLu x = M Jd�tj yOQ. zu Qiy to Y W,i�N ¢2� 4 Q ti ti I 9A w 54,263 SF ? I 1.24 AC J � I 20'UTILITY&DRAINAGE I--�� EASEMENT O I M. B. 55, PG. 33-34 N ix G v W f0' NON -ACCESS BUFFER p M.B. 55, PG. 33-34 a iL HALSTEAD BOULEVARD EXTENDED - NC HWY 344 (R/W VARIES AS MONUMENTED) N79°1928 E 444.00' 20 ' UTILITY & DRAINAGE T EASEMENT J MB. 55, PG. 33-34 98 #3870 35,357 SF 0.81 AC PROPOSED f0'DR4IN4GE EASEMENT CENTERED ON PIL _ PROPOSED VARIABLE WIDTH DRAINAGE EASEMENT K C9 0 20'UTILITY&DR4INAGE S104032E_ N55°4032"W EASEMENT 76.73' 28.28' M.B. 55, PG. 33-34 C14 123.88' PA TRICK WAY (PRIVATE 60' R/W) ?8 E 123.88' L5 TANGLEWOOD CONTROL MONUMENT 3 -� NC GRID NAD 83 R` \Z N 936,716.2635 sFT O \ N E 2,797,665.1499 sFT mm � 3 \� 96,56' Ll--------------- 5' CAROLINA TELEPHONE EASEMENT D.B. 1071, PG. 290 10 PARKWAYSOUTH ATTANGLEWOOD PHASE 2A M.B. 55, PG. 33 & 34 N c� Lu M a o PROPOSED CROSS ACCESS, UTILITY, y & DRAINAGE EASEMENT FOR LOTS 9A & 9B (SEE TABLE BELOW) (SEE INSET AT RIGHT) EXISTING CROSS 42 ACCESS EASEMENT MKKD-B. B. 55, PG. 33 & 34 f143, PG. 169 EE TABLE BELOW) CJ v h1 C6 p/ N34°1928"E 20'UTILITY&DRAINAGE _ 26.28' EASEMENT \ M.B. 55, PG. 33-34 1 ` EXISTING EASEMENT LINE TABLE NEW EASEMENT LINE TABLE LINE BEARING LENGTH LINE BEARING LENGTH L 1 N2°5123"E 68.54' L4 N10 4032W 93.50' L2 S87°0837E 48.32' L5 N79°1828 E 70.00' L3 S2°5123"W 69.00' 0 �M 0 v 2 S79°1928"W • - - • 90.00, PUMP STATION LOT b M.B. 47, PG. 31,32 00' 2 FUTURE PHASE 2B (16.61 AC) M. B. 55, PG. 33 & 34 CURVE TABLE CURVE RADIUS LENGTH TANGENT DELTA CHORD BEARING CHORD CI 540.00' 192.96' 97.52' 20 2825' N89°3340'E 191.93' 02 600.00' 359.26' 185.20' 34°1824' N823841 E 353.92' C3 720.00' 169.66' 85.24' 13*30'11" N72'1432 E 169.29' C4 780, 00' 184.17 92.52' 13°3142" S72°15'18"W 183.74' C5 1540. 00' 179.07' 90.36' 18°5958' S74°5928"W 17825' C6 540.00' 144.27' 72.57' 15°1826" N87°5120"W 143.84' C7 600.00' 58.30' 29.17' 5°3400' N82°5907"W 58.27' C8 600.00, 156. 10' 78.50' 14°5425' S66 4640'W 155.66' C9 675.00' 125.90' 63.13' 10°41'13' N8527'42E 125.72' C10 600.00' 42.91' 21.46' 4°0551° N82°15'02"W 42.90' C11 600. 00' 15.39' 7.69' 12809" N85°02'02'W 15.39, C12 600.00' 20.61' 10.30' 1'5804' N86°45'09"W 20.61' C13 600.00' 12.35' 6.1T 1°1045" N88°1933"W 12.35' C14 600.00, 38.52' 19.27' 34043' S89°1443W 38.51' C15 600.00' 84.63' 42.39' 8°0434" S83 2135"W 84.56' N79°1928'E 422. 10' 323.54' `t 1 1 1 1 1 1 1 t DRAINAGE EASEMENT 1` 20.M B. 55, PG. 33-34 � t t Rl 1 i � 1 i O � t t 1 1 t 1 t t � I a I � a e u C u C VG CROSS I U S ESMT PG. 33-34 I M `. a N M L M a I� a I � N L h Lu WNW R I 2 N 0 m t 1 INSET I o t 1 (1'=40) cou ICT tt tt .___---- • NO CA W 1 1 %�6� W i v S65 11 �.I $ o 1 C5 1 1 F� � 'rufzN' - C3_----- • 1 -- _ 1 1 N65°29=E"� 1- - C2 _ - JASON A. MIZELLE P.L.S. L-4917 I F/=Fnln - - - - - - - - BENCHMARK EXISTING IRON ROD (EIR) O SET IRON ROD (SIR) CALCULATED POINT MAGNETIC NAIL 0 PROPERTYBOUNDARY Io PROPERTY EXTENSION - - - - o PROPERTY TIES - - - - - - - W RIGHT-OF-WAY M FUTURE RIGHT-OF-WAY - - - - - -_ a PHASE LINE o COMMUNICATION EASEMENT -------------------------- I� NONACCESS BUFFER - - - - - - - - - - - - EXISTING UTILITY& DRAINAGE EASEMENT 40' DRAINAGE EASEMENT NEW DRAINAGE EASEMENT M.B. 55, PG. 33-34 EXISTING CROSS ACCESS EASEMENT NEW CROSS ACCESS, UTILITY, & DRAINAGE EASEMENT FOR LOTS 9A & 9B � I cn I U0 Lu SON � aN ? N o m (1"=100) ( O ZONED: GB (ELIZABETH CITY) - - • 65..75' - + 40.00' 82.35' S79°1928'W 740.35' ZONED: C-1(PAS000TANK COUNTY) S79°19'28W 188.10' ✓ �( -� TANGLEWOOD CROSSING, LLC FUTURE DEVELOPMENT (28.47AC) D.B. 1017, PG. 808,M.B. 48, PG. 6 (SEE INSET AT LEFT) ZONED: C-1 (COUNTY) t REVISION NOTE: 1.) REVISED 9A - 9B LOT LINE 07-06-2020. C ZZ C�N�sl RECEIVz3 NOV 3 01E20 SCALE 1 "=60' 0 60' 120' FOR TIDAL WAVE AUTOS A 3880 PATRICK WAY ELIZABETH CITY NORTH CAROLINA, 27909 eo4a4i CIVIL MARINE ENVIRONMENTAL (PIN# 7993760366) AUGUST 1, 2016 REVISED DECEMBER 13, 2016 EMC PROJECT NO. 16=6038 DEVELOPER/RESPONSIBLE PARTY: SHJ CONSTRUCTION GROUP 124 E THOMSON ST THOMASTON, GA 30286 PHONE: (706)-975-1983 FAX: (706)-647-0474 # 4SHJ Constructi Design -Build EMC ENGINEERING SERVICESi INC. ENVIRONMENTAL - MARINE - CIVIL= SURVEY ALBANY, ATLANTA, AUGUSTA, BRUNSWICK, COLUMBUS, SAVANNAH (CORPORATE), STATESBORO AND VALDOSTA ME= ST."BUN PR P T� N DEC 19 2016 UNIPN�T VICINITY MAP NOT TO SCALE INDEX OF DRAWINGS SHT DESCRIPTION NO. C-01 COVER C-02 GENERAL NOTES & LEGEND C-03 EXISTING CONDITION & DEMOLITION PLAN C-04 SITE & STAKING PLAN C-05 UTILITIES PLAN C-06 PAVING, GRADING, & DRAINAGE PLAN C-06.1 PROFILES C-07 HYDROLOGY PLAN U-N-1 CONSTRUCTION DETAILS C-11 LANDSCAPE PLAN EC-01 EROSION CONTROL COVER EC-02 INITIAL EROSION & SEDIMENTATION CONTROL PLAN EC-03 INTERMEDIATE EROSION & SEDIMENTATION CONTROL PLAN EC-04 FINAL EROSION & SEDIMENTATION CONTROL PLAN EC-05 EROSION & SEDIMENTATION CONTROL NOTES EROSION & SEDIMENTATION CONTROL DETAILS titttt wwerrr+ay EMC ENGINEERING SERVICES, INC. !sue`' 1344 U.S. HWY 19 SOUTH LEESBURG, GEORGIA 31763 '= PHONE: (229) 435-6133 FAX: (229) 439-7979 albany@emc-eng.com r'0010wwa O GENERAL NOTES: 1. IT IS THE INTENT OF THE OWNER TO CONSTRUCT A NEW CAR WASH LOCATION WITH THE REQUIRED UTILITIES AND PARKING LOT ASSOCIATED WITH THE NEW CONSTRUCTION. 2. ALL CONSTRUCTION SHALL CONFORM TO THE ELIZABETH CITY AND/OR NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS. 3. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSURE THAT ALL REQUIRED PERMITS ARE OBTAINED AND IN HAND PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 4. THERE ARE NO KNOWN ZONING CONDITIONS FOR THIS PROPERTY. 5. THE DATA, TOGETHER WITH ALL OTHER INFORMATION SHOWN ON THESE PLANS, OR IN ANY WAY INDICATED THEREBY, WHETHER BY DRAWINGS OR NOTES, OR IN ANY OTHER MANNER, ARE BASED UPON FIELD INVESTIGATIONS AND ARE BELIEVED TO BE INDICATIVE OF ACTUAL CONDITIONS. HOWEVER, THE SAME ARE SHOWN AS INFORMATION ONLY, ARE NOT GUARANTEED AND DO NOT BIND THE ENGINEER IN ANY WAY. 6. UNDERGROUND UTILITY INFORMATION SHOWN HEREON IS BASED ON GROUND MARKINGS BY OTHERS. NO CERTIFICATION IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THIS INFORMATION. VISIBLE EVIDENCE OF UTILITY STRUCTURES OBSERVED DURING THE COURSE OF THE FIELD SURVEY IS SHOWN HEREON. 7. PRIOR TO INSTALLATION OF ANY UTILITY LINES, THE CONTRACTOR SHALL GIVE THE UTILITY COMPANIES THREE (3) WORKING DAYS NOTICE TO ALLOW TIME FOR EXISTING UTILITIES TO BE STAKED. BEFORE CALLING (811) THE CONTRACTOR SHALL HAVE THE FOLLOWING INFORMATION READY: COUNTY, TOWN, LOCATION, NEAREST STREET INTERSECTIONS, TYPE OF WORK (SEWER, WATER, PAVING, ETC.) YOUR COMPANY NAME, TELEPHONE NUMBER, OWNER'S NAME, DATE AND TIME YOU EXPECT TO COMMENCE CONSTRUCTION, AND WHERE AND HOW YOU CAN BE REACHED AND THE BEST TIME TO CONTACT YOU. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING AN UNDERGROUND UTILITY, WHETHER SHOWN ON THE PLAN OR LOCATED BY THE UTILITY COMPANY. ALL UTILITIES WHICH INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE RELOCATED BY THE RESPECTIVE UTILITY COMPANIES, AND THE CONTRACTOR SHALL COOPERATE WITH THEM DURING RELOCATION OPERATIONS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY VARIANCES PRIOR TO COMMENCEMENT OF WORK OR PURCHASING ANY MATERIALS. 8. ALL KNOWN UTILITY FACILITIES ARE SHOWN SCHEMATICALLY ON THE PLANS AND ARE NOT NECESSARILY ACCURATE AS TO PLAN OR ELEVATION. UTILITY FACILITIES SUCH AS SERVICE LINES OR UNKNOWN FACILITIES NOT SHOWN ON THE PLANS WILL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES, EXCEPT AS NOTED BELOW. THE CONTRACTOR WILL NOT BE RESPONSIBLE FOR THE COST OF REPAIRS TO DAMAGED UTILITY FACILITIES OTHER THAN SERVICE LINES FROM STREET MAINS TO PROPERTY WHEN SUCH ABUTTING FACILITIES ARE NOT SHOWN ON THE PLANS AND EXISTENCE IS UNKNOWN TO THEIR THE CONTRACTOR PRIOR TO THE DAMAGES OCCURRING PROVIDING THE ENGINEER DETERMINES THE CONTRACTOR HAS OTHERWISE FULLY COMPLIED WITH THE SPECIFICATIONS. 9. IT IS THE OBLIGATION OF THE CONTRACTOR TO MAKE HIS OWN INTERPRETATION OF ALL SURFACE AND SUBSURFACE DATA THAT IS AVAILABLE AS TO THE NATURE AND EXTENT OF THE MATERIALS TO BE EXCAVATED AND WASTED, AND/OR GRADED AND COMPACTED. THE INFORMATION SHOWN ON THESE PLANS AND SPECIFICATIONS DOES NOT IN ANY WAY GUARANTEE THE AMOUNT OR NATURE OF THE MATERIAL WHICH MAY BE ENCOUNTERED. 10. FILL MATERIAL SHALL BE CLEAN AND FREE OF ALL DEBRIS AND ORGANIC MATERIAL. 11. ALL STORM PIPES SHALL BE HDPE UNLESS OTHERWISE SHOWN ON PLANS. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND FURNISHING THE BORROW MATERIAL NECESSARY FOR THE CONSTRUCTION OF THIS PROJECT. 13. ALL DISTURBED EARTH AREAS, NOT DESIGNATED TO BE PAVED, SHALL BE GRASSED WITH TEMPORARY SEEDING OR PLANTED WITH PERMANENT VEGETATION 14. A BOUNDARY & TOPOGRAPHIC SURVEY WAS PERFORMED BY E.T. HYMAN SURVEYING, PC ON MAY 3, 2016. 15. THE TOTAL ACREAGE OF THE AREA OF THE PROJECT IS t2.06 ACRES. THE TOTAL DISTURBED ACREAGE OF THE PROJECT IS: t2.0 ACRES. 16. THE PROJECT IS LOCATED ON THE CORNER OF S MOUNT EVEREST DRIVE AND PATRICK WAY IN PASQUOTANK COUNTY, NORTH CAROLINA. 17. IF ANY CONFLICTS, DISCREPANCIES, OR OTHER UNSATISFACTORY CONDITIONS ARE DISCOVERED, EITHER ON THE CONSTRUCTION DOCUMENTS OR THE FIELD CONDITIONS, THE CONTRACTOR MUST NOTIFY THE ENGINEER IMMEDIATELY, AND SHALL NOT COMMENCE OPERATION UNTIL CONFLICTS, DISCREPANCIES, OR OTHER UNSATISFACTORY CONDITIONS ARE RESOLVED. 18. ALL PROPOSED PAVEMENT ELEVATION SHOWN (EX. +312.57) ARE PROPOSED ASPHALT OR CONCRETE FINISH GRADE AND NOT TOP OF CURB UNLESS OTHERWISE NOTED. 19. ALL STRIPING AND SIGNS SHALL BE IN CONFORMITY WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS, LATEST EDITION. 20. THERE ARE NO WETLANDS OR STATE WATERS WITHIN 200 FEET OF PROJECT SITE. THERE ARE NO IMPAIRED STREAM SEGMENTS WITHIN ONE MILE OF THE PROJECT SITE.THE PROJECT RECEIVING WATER IS PASQUOTANK RIVER. 21. ACCORDING TO FEMA FLOOD INSURANCE RATE MAP COMMUNITY PANEL NO. 3720798200J, DATED OCTOBER 5, 2004 SHOW THIS PROPERTY IS NOT LOCATED IN A DESIGNATED FLOOD HAZARD AREA. 22. DEVELOPER: PROPERTY OWNER: SHJ CONSTRUCTION GROUP TANGLEWOOD CROSSING DEVELOPMENT, LLC 124 E THOMSON ST 1108 TIDEWATER DR THOMASTON, GA 30286 NORFOLK, VA 23504 PHONE: (706)-975-1983 FAX:(706)-647-0474 23. THE POINT OF CONTACT FOR CIVIL SITE WORK FOR THIS PROJECT IS: CHRISTOPHER E. BRAZELL, P.E. BRIAN BRAUN, P.E. EMC ENGINEERING SERVICES INC. 3575 MACON ROAD, SUITE 15 COLUMBUS, GEORGIA 31907 (706)565-5985 24. 24 HOUR CONTACT: JOHN WELLS (706)-975-1983 LEGEND EXISTING PROPOSED CLEANOUT o Go • SANITARY MANHOLE QMH GREASE TRAP OGT •GT SANITARY SEWER LINE ss- SS - STORM SEWER PIPE ST lmrmmmg:� DRAINAGE MANHOLE OD FLARED END SECTION INVERT ELEVATION iE 12.00 IE 12.00 CURB INLET TYPE A E ❑O CURB INLET TYPE B Z21 /Q CURB INLET TYPE C F, N ROOF INLET GRATE INLET ® ❑O RIP RAP BUILDING LINE - - - - SITE SURFACE SLOPE ARROW �1�p CENTERLINE OF ROAD - - -_- EDGE OF ASPHALT CURB & GUTTER EDGE OF CONCRETE - - EDGE OF GRAVEL EDGE OF DIRT - EDGE OF DRIVEWAY - - - - GUARDRAIL SPOT ELEVATION X 12.00 +12.00 CONTOURS - -12 CENTERLINE OF DITCH - - ----- WATERS EDGE SILT FENCE (SINGLE) x X x X ->t -->t-X- POWER POLE 0PP •PP GUY POLE m GP v GP LIGHT POLE [P *LP GROUND LIGHT G[ Q GL t ELECTRICAL MANHOLE ©MH •MH ELECTRICAL CONTROL BOX EC8 ECB 0 ELECTRICAL SERVICE METER ELECTRICAL TRANSFORMER TRANS ® TRANS ® OVERHEAD POWER CABLE W N N N p s a m o 0 0 z O H a 3 w 3 w 3 w w w z WZ U U U it O a m a z z z j W 0 N w 0 !O w 0 N w O N M z , I , I , I , 3 fi,`r ��33�iCfJ�dy'tjf°t,J z t +''�J`r+ittttlttiilli; 114* Z -NU � Y U N W Z =m z W Q O��E Z ~mQ V)W�o Wo /v^ W �(7& y CJJ Z U xUN� o rn E CD ¢> Lu Lf. z a V W w° c cc .0 z -1d C max m Q0 o G W m z W Z J m Q N a ~ z ¢ z wm U it,4 z 5;� W W 0 J 0 = U m Cm O Q Q>' N U a Z W C9 O �- J O IL O W J Q V a=�Z V C N LLI W w F-�0 ~ � o >a °z Q- :5 -� coo a N J co vLLJ O V W � Q m = ~ N � J W PROJECT NO.: 16-6038 DRAWN BY: RAP DESIGNED BY: BHB SURVEYED BY: EMC SURVEY DATE: 06/03/2016 CHECKED BY: CEB SCALE: - DATE: 08/01/2016 SHEET C=02 OF 19 0: \2016\16-6038 SHJ - TIDALWAVE CARWASH ELIZABETH CITY, NC\DWG\16-6038C-0O2.DWG 12/14/2016 11:58 AM GENERALNOTES SEWER VALVE S 8333.55 _w 74_65. (CITY LIMITS) C3q} I�ALSTEAD -v E' � -- ------ vv ------------- - -- _ - -- -- - __ - (CITY LIMITS) � ---22--- ----- ----__z1"6-__----___- - 4-5 __- --- - - __- ---- -14- _ N 79.19' CDOT'FIBFROPTJG 66X , -' _ - _ - - - - - - - _ - _ _ G -T jA61PISI NAL POLE" .' � - TELEPHONE BOX C LECrTRIC'TRANs�RMEI - --' TILITY EA�ME N�S� E j T� K, / 20 2� i IjfD RGROU' ND', ynBOX�SETgA� 50, gU� IN0 15.6 \ I 1 I I {' --- LOT 10 PARKWAY SOUTH AT TANGLEWOOD `I 15.7 PHASE 2A 1 11 I 1 1 (PLAZA AZTECA) 1 X1 ' 'I i h ZONING: GB ----------------- / ' _ - LOT 9 1 s� PARKWAY SOUTH 1 ` 1 AT TANGLEWOOD A N PHASE 2A (MB 55/34) \ M ZONING: GB A� 1 Q70' NON -ACCESS SUFFEi �? r l� 89,621 sE ' 1 �I 2.06 ACRES .III 1�1 l , PROPOSED CROSS ACCESS EASEMENT It S 79*19'28" W - 58.50' A ` 1 0 0 N 10*40'32" W - 37.36' l o S 10'40'32" E- 38.10' 15.7 870837" E- 76.48' I �_837' E - 31.84' ` EXISTING GROSS CCESS EASEMENT -I -7 DEMO AND REMOVE E)3kTING FES / 1 1I, ASPHALT ql� 18' RCP 1 I } S /NV = 12.92' 1 3 1 SAWCUT & REMOVE h N 1 e" RCP ' s 1 1 I ��, A EXISTING CURB,i60LF � my = 1za7' � I ' RED OVC MARKER _ I a1 1 IIS T? CONNECTION _- _ AC-��UGP UGC yG �N _SE_TB r EONNE G SEWER . "� -}6 l r R=600.00' ONNECTION- 1 1 I ---- �-20 7\N - ___- --- -� CH3 --sFTg.A -- ---- - _ -d._ - -EX °SID'EWALK- _� i N8T 20 031"W EANDS UGP _--123.8816 _ a -.> a o "w - --- 8"w 8"W 8"PVC w- - _CH: 122RIM = 16.23' 0GP - - - - 8„W R-6 0.72' .6„W S ,�\ - INV - - - - - - R=600. 0- VC \CFI I TRANSFORMER _ � ° - _ 8" P SS N 55.40'32" IN - 28.28', s - y_ Ex° StOEVALK _ ---- 8 �CKwSy ss PAT60' R/W) ss 1 SS 8" PVC 8" PVc ss �- I S"W Iss ss RIM = Z O NV = .6161' � 1. E.T. HYMAN SURVEYING, PC PERFORMED AN EXISTING CONDITIONS / TOPOGRAPHICAL SURVEY OF THIS PARCEL ON MAY 3, 2016.. THERE MAY BE EASEMENTS, SETBACK LINES OR OTHER MATTERS AFFECTING THIS PROPERTY THAT ARE NOT SHOWN ON THIS SURVEY. 2. THERE ARE NO STATE WATER LOCATED ON OR WITHIN 200' FEET OF SUBJECT PROPERTY. 3. THE CONSTRUCTION AREA ULTIMATELY DRAINS TO THE PASQUOTANK RIVER. 4. NO ENVIRONMENTAL ASSESSMENT HAS BEEN PERFORMED BY EMC ENGINEERING SERVICES, INC 5. THE EXISTING SITE IS AN UNDEVELOPED COMMERCIAL PARCEL. 6. THE AREA FOR THIS PROJECT IS t2.1 ACRES WITH A DISTURBED AREA OF t2.0 ACRES. 7. THE ELIZABETH CITY PUBLIC WORKS SHALL BE NOTIFIED 72 HOURS PRIOR TO BEGINNING WORK AND 24 HOURS PRIOR TO RESUMING WORK AT (252)-338-3981. 8. ALL CONSTRUCTION MATERIALS SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS AND REQUIREMENTS OF ELIZABETH CITY IF NOT OTHERWISE SPECIFIED, ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE SC DOT STANDARD SPECIFICATIONS FOR CONSTRUCTION. DEMOLITION AND EXISTING CONDITIONS NOTES: 1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BEGINNING DEMOLITION AND/OR NEW WORK. NOTIFY ENGINEER IN WRITING OF ANY DISCREPANCIES OR CONFLICTS. 2. CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY BARRIERS & WARNINGS TO LIMIT ACCESS TO PROJECT AREA TO ONLY THOSE PERSONNEL AUTHORIZED BY THE CONTRACTOR. INASMUCH AS AREAS ADJACENT TO PROJECT AREA WILL MAINTAIN "NORMAL OPERATIONS," 3. CONTRACTOR SHALL PROVIDE ADEQUATE DUST CONTROL MEASURES & SHALL MAINTAIN SAFE PASSAGEWAY FOR WORKERS & NON -WORKERS AS REQUIRED ADJACENT TO THE PROJECT SITE. 4. ALL ITEMS REMOVED OR DEMOLISHED BY THE CONTRACTOR WHICH ARE NOT LISTED BY THE SPECIAL PROVISIONS TO BE TURNED OVER TO THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR & SHALL BECOME THE CONTRACTOR'S RESPONSIBILITY FOR PROPER DISPOSAL. 5. DEMOLITION ACTIVITIES ARE NOT EXPECTED TO INCLUDE THE REMOVAL OF HAZARDOUS MATERIALS. IN THE EVENT THAT THAT HAZARDOUS MATERIALS ARE ENCOUNTERED OR SUSPECTED, CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING OF THE MATERIAL. 6. CONTRACTOR SHALL COORDINATE WITH APPROPRIATE UTILITY COMPANIES TO SCHEDULE ALL UTILITY & SERVICE INTERRUPTIONS TO OCCUPIED PORTIONS OF THE SITE. 7. CONTRACTOR SHALL REMOVE TREES AS INDICATED ON CIVIL PLANS. CONTRACTOR SHALL USE CAUTION DURING ALL CONSTRUCTION ACTIVITIES TO PROTECT ALL TREES INDICATED TO REMAIN. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE CLEAN-UP, CLEARING AND GRUBBING PER SPECIFICATIONS. ALL TREES THAT HAVE A MARKETABLE VALUE SHALL BE SALVAGED. CONTRACTOR SHALL COORDINATE WITH OWNER AS TO THE TREES TO BE RELOCATED OR SOLD 8. CONTRACTOR SHALL SAW CUT EXISTING CONCRETE AND ASPHALT PAVEMENTS AT LIMITS OF DEMOLITION TO LEAVE SMOOTH EDGE ON REMAINING CONCRETE/PAVEMENT. FLOODPLAIN NOTES THE PROPERTY SHOWN HEREON IS LOCATED ON MAP NO. 3720891400K OF THE FEMA FLOOD INSURANCE RATE MAP COVERING PASQUOTANK COUNTY, NORTH CAROLINA, REVISED JULY 19, 2005 AND SHOWS THIS PROPERTY IS NOT LOCATED IN A DESIGNATED FLOOD HAZARD AREA. UTILITY NOTES: 1. THE LOCATIONS OF UNDERGROUND UTILITIES AS SHOWN HEREON ARE BASED ON ABOVE -GROUND STRUCTURES PROVIDED BY THE SURVEYOR. LOCATIONS OF UNDERGROUND UTILITIES / STRUCTURES MAY VARY FROM LOCATIONS SHOWN HEREON. 2. UNDERGROUND UTILITIES / STRUCTURES MAY BE ENCOUNTERED. NO EXCAVATIONS WERE MADE DURING THE PROGRESS OF THIS SURVEY TO LOCATE BURIED UTILITIES / STRUCTURES. 3. BEFORE EXCAVATIONS ARE BEGUN, GIVE THREE WORKING DAYS NOTICE TO THE UTILITIES PROTECTION CENTER AT 811 PRIOR TO ANY EXCAVATION IN ORDER THAT UNDERGROUND UTILITIES MAY BE LOCATED AND PROTECTED. HATCH LEGEND: DEMOLITION AREA, EXISTING SIDEWALK N N N } w w w 00 o a o z O a W U U U 0. a a _O j 0 W 0 W 0 W � w x IMM©©NEEN �•`. ti( i T Y c:j 0,1 .7 ri Y ssyy { a. t''1Sd L. t\ " fit 20' ' 20' 10, 0' 20' GRAPHIC SCALE: 1"-20'-0" Z U rRZ =� co W ~ < M LU y 00, E oa 0 w cQ rm o U� rn +nrn c- YO Z Z W w V n OF U o rn Va� V N U A Z x09N0E 0Z c,- rn E Z z cn�WCN �¢ LJ.I Z m U � w O X 0 co-1aQQw m Z)M v' D w Q Q W a; W a z Z 1:gz G Z > za z z `�w66 O z JC) a N a Q J H (n z a O O Q Q a U �1 V O , V z otf = z O > Q a O z R C� a o z J Go O0 v z 0 Q W U z � N `z r X W W PROJECT NO.: 16-6038 DRAWN BY: RAP DESIGNED BY: BHB SURVEYED BY: EMC SURVEY DATE: 06/03/2016 CHECKED BY: CEB SCALE: 1 "=20' DATE: 08/01/2016 SHEET C=03 OF 19 SITE INFORMATION VE--_� W _ 1465. LIMITS) S.rgAD gLv V1 ) - NC 344 IN qL/W CONTRACTOR TO EXTEND SIDEWALK TO UAI CTCAn CI tin 1 nn A' � I UILDING PRw" Do' 3.0v A 1 Q70' NON -ACCESS BUFFER I LLo O 11 1 mQl) If:°II I Q) Z 1 O 11 Il 1 1 Ia °1 F64 - 8"W N 5540'32" W - 8"W SS RIM = 17.21'� INV = 0.61' SS SS R= 600.00' 12315' ASPHALT SS Irs) E_ 19� � N 79'192e � LOT 10 PARKWAY SOUTH AT TANGLEWOOD PHASE 2A (PLAZA AZTECA) ZONING: GB 10*40'32" W - 37.36' 18" RCP (FES) INV = 12.57' 1 8" RIM = 16.2 It INV = 1.93' 1V X 7V SIGHT TRIANGLE I SS -8 PVC If I ADDRESS: 3880 PATRICK WAY, ELIZABETH CITY, NC PROPERTY AREA: t2.1 AC PROPERTY ZONING: GB - HALSTEAD OVERLAY DISTRICT TAX MAP: TM P56-37 EXISTING USE: UN -DEVELOPED COMMERCIAL LOT PROPOSED USE: CAR WASH & VACUUM PURPOSED IMPERVIOUS AREA: 32,667 SF (0.75 ACRES) (36% OF TOTAL SITE) BUILDING SETBACKS: FRONT: 20 FEET (ALONG RAV) SIDE: 0 FEET REAR: 50 FEET LANDSCAPE SETBACK: FRONT: 15 FEET(ALONG RAN) SIDE: 15 FEET(ALONG RAN) REAR: 25 FEET(ALONG RAN) PARKING NOTE PARKING REQUIRED: PARKING PROVIDE: STACKING FOR 30 CARS STANDARD SPACES = 25 3 SPACES IN DRYING AREA HC SPACES = 1 +2/3 SPACES PER EMPLOYEE TOTAL PROVIDED = 26 SPACES 3+(3)3= 5 SPACES SITE LAYOUT AND STAKING NOTES 1. IF THE PLANS ARE NOT CLEAR OR DISCREPANCIES OCCUR, THE CONTRACTOR IS TO CONTACT EMC ENGINEERING SERVICES, INC AT 229-435-6133 FOR CLARIFICATION IMMEDIATELY. 2. ALL NORTHING AND EASTING ARE TO THE FACE OF CURB, EDGE OF BUILDING. 3. CONTRACTOR SHALL CAREFULLY EXAMINE ALL DOCUMENTS AND THE CONSTRUCTION SITE TO OBTAIN FIRST HAND KNOWLEDGE OF EXISTING CONDITIONS. 4. ENTIRE SITE SHALL BE DRESSED TO UNIFORM, WELL DRAINED AND VISUALLY APPEALING SURFACE WITH A MINIMUM TOPSOIL LAYER OF FOUR INCHES. 5. ALL STRIPING AND SIGNS SHALL CONFORM WITH THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) LATEST EDITION. PARKING STALL STRIPPING TO BE YELLOW WITH BLUE HANDICAPPED STRIPPING 6. ALL HANDICAP PARKING SPACES AND ACCESSIBLE ROUTE SHALL CONFORM WITH THE AMERICAN WITH DISABILITY ACT DESIGN GUIDELINES AND SPECIFICATIONS LATEST EDITION. 7. DIMENSIONS AND CURVE RADII ARE GIVEN TO FACE OF CURB, WHERE CURB AND GUTTER IS SHOWN. OTHERWISE DIMENSIONS ARE GIVEN TO THE EDGE OF PAVEMENT. CONTRACTOR IS TO COORDINATE WITH THE ARCHITECTURAL PLANS AS TO THE BUILDING LAYOUT AND DIMENSIONS HATCH LEGEND: CONCRETE PAVEMENT EXISTING CONCRETE SIDEWALK SPECIAL NOTES: OTYPE "B" HANDICAPPED RAMP O 6" HEADER CURB O24" WIDE WHITE STOP BAR STRIPING 4O 4" WIDE YELLOW PARKING STALL STRIPING O 5" WIDE YELLOW CENTERLINE STRIPING O VAN ACCESSIBLE HANDICAP SIGN 7O HANDICAP STALL STRIPING SO STOP SIGN - 36"X36" (R1-1) O4" YELLOW HAZARD STRIPING 10 3' CONCRETE FLUME 11 SIGN LOCATION (SIGN PERMIT REQUIRED) 12 ONE WAY SIGN 0 CONCRETE SIDEWALK o LW r N N N Q o r �n } w w w m ❑ o o Z O H a W W W U U Luit it W U U U LIJ a a a _o Z Z co W O_ D w O_ D w O D w It O N C Z :xC1�� tca32. c 0 ��.`•. '�l � Ire _� _� 20' IV 0' 20' GRAPHIC SCALE: 1"=20'-0" 0 Z� ♦ V Z = � 03 W � m U) co Vj 0) o U o co 0 Z W ov�m rn N IZ Uo a(7 27Nm E Zp Z ?rna wv mU zz W ¢ W Iq) �0 VW'^ (0 C V/JO_LL 0U) W c � � ¢¢ W ¢ cn J W J Z = g¢ U W Q Z Z cr z¢ m z ¢ in `�W LL C) O Q N v' Z 0. J Q W O C9 v o 0 Z _ Z Q UJ � O m V � Qa?4) 06 o a N w in v Z N Q � U m 2 � N � _J w PROJECT NO.: 16-6038 DRAWN BY: RAP DESIGNED BY: BHB SURVEYED BY: EMC SURVEY DATE: 06/03/2016 CHECKED BY: CEB SCALE: 1 "=20' DATE: 08/01/2016 SHEET C=04 OF 19 �,STE lR/w ��IESI CONTRACTOR TO EXTEND SIDEWALK TO HALSTEAD BLVD.132.0' CONTRACTOR TO ADJUST MANHOLE LID TS)� - LIM � (CITY � 195 7109 -5 _ 248.23 _ N 79'19'28" E C T FIBEROPTIC BOX R VALVE---." ) TRAFFIC SIGNAL POLE ELECTRIC TRANSFORMER TELEPHONE BOX 2 EA2--LA- PESETBACK, - / SEME= S_Ir_- 8'S5' 1465.88 � (CITY LIMITS) ,UND RGROUND _ / UTILI Y BOX BUJ_ INSSEK �A� J 2 � �- 1 1 1 °I I" I A 20L.F. 4" PVC @ 2.30% 1 °I / 1 < I Co OIL 1 GRIT SEPARATOR NI 1 i ( INV IN:14.19 I I l INV OUT:14.19 1 1 CO X I WATER R CLAIM SYSTEM; O° j t gal SEED TAIL SHEET 15. 1 Lo 1 I I I O° 1 1 1 I O O LOT 9 I I N PARKWAY SOUTH I 1 O ° 1 79L.F. 4" PVC @ 2.30% AT TANGLEWOOD I 1 WATER RECLAIMLINE PHASE 2A (MB 55/34) IS I W 1v 13-LF4"PVC f ZONING: GB Q10' NON -ACCESS BUFFER� CCC7���I �I `• • ` C L''z IS "1 I 89,621 SF 1 I { 1 N 2.06 ACRES r) 1 I 1 m b C9 If °11 I 1 p oT CO-A4 LL o 1 O 06 RIM:17.58 1 I z U) U) Go 1 INV IN:12.38 �� INV OUT:12.38 d� I �I I@I ZI 11 I 7 LL a C I OG W Qcou. CO 1 dLL ® l = U U- 1 w 44L.F. 4" P @ 4.14° r7J 11 m I I m 1 COMA I s RIM:1 .53 INV IN 0.56 68L.F. 4" PVC INV O :10.56 ® i7 1' =ry I I • CO t of 'I I ss � 11 ZI I o II 11 1 II I 1I I I CO-A2 II �5 I I ss RIM:16.46 11 1 I �I INV IN:8.75 1 I INV OUT:8.75 157-LF 1 y" PCV (C900) co 62L.F. 4" PVC @ 11.129 rs I s l I 2 t► STUB OUT WITH CLEAN OUT FOR FUTURE EXPANSION LOT 10 PARKWAY SOUTH AT TANGLEWOOD PHASE 2A (PLAZA AZTECA) ZONING: GB 6" CONDUIT FOR FUTURE 1 UTILITY EXPANSION 1 1 1 1 � =BA CO -Al UGP ------- T/BUILDING RIM:16.29 /EXISTING CONNECTIONSWER A EN SEM INV IN1 ..84 1 20' UTILIDOMEST 1 SERVICE APE SETBACK 1-20GATE VALVE 0 -- - 15' LA GP 1- 2' METER IN BOX IRRIGATION SERVIC 79'1928" W 1-2'BFPINBOX ' _-f 6"W - i TWN BOX 5 _ - - - _ - PV 1-1" RPZ BFP LECTRIC TRANSFORMER 1" PVC IRRIGATION - N 55'40'32" W - 28.28', S _ SERVICE LINE C900 � � _ ( ) _ a-.r _- e ems_ S _�`-811W TgiCK�'�7A pA(61Yg/w) 1- 2" TAP; CONTRACTOR TO Ss 8" PVC COORDINATE CONNECTION WITH - 6"W ELIZABETH CITY PUBLIC WORKS - _ss�� 8"W RIM = 17.21' INV = 0.61' ASPHALT y I I 18" RCP (FES) INV = 12.57' PVC UGP R=500.00' )O _ - - S - - - d EX: °SIDEWALK_ W 8"W CH:122.94' S85. 12' 16"W R=600.00' 123.15' ASPHALT 8 PVC SS SS \-60 SANITARY SERVICE CONNECTION; SS - CONTRACTOR TO COORDINATE CONNECTION WITH ELIZABETH CITY PUBLIC WORKS INV IN: 1.48 32.95' C25' N87* 20'0" 31"W 8" Pvc T RIM = 16.23' INV = 1.93' I I 1 I SITE INFORMATION ADDRESS: 3880 PATRICK WAY, ELIZABETH CITY, NC BUILDING SETBACKS: PROPERTY AREA: t2.1 AC FRONT: 20 FEET (ALONG RNV) SIDE: 0 FEET PROPERTY ZONING: GB - HALSTEAD OVERLAY DISTRICT REAR: 50 FEET TAX MAP: TM P56-37 LANDSCAPE SETBACK: FRONT: 15 FEET(ALONG R/W) EXISTING USE: UN -DEVELOPED COMMERCIAL LOT SIDE: 15 FEET(ALONG R/M PROPOSED USE: CAR WASH & VACUUM REAR: 25 FEET(ALONG RAN) PURPOSED IMPERVIOUS AREA: 32,667 SF (0.75 ACRES) BUILDING: 3,327 SF (10.0%) CONCRETE SIDEWALK: 760 SF (2.4%) CONCRETE PAVEMENT: 28,580 SF (87.6%) UTILITY NOTES 1. THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES AS SHOWN HEREON ARE BASED ON ABOVE -GROUND STRUCTURES AND IS APPROXIMATE AND SHOWN FOR INFORMATIONAL PURPOSES ONLY. NO CERTIFICATION IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE THIS INFORMATION. 2. ADDITIONAL BURIED UTILITIES / STRUCTURES MAY BE ENCOUNTERED. NO EXCAVATIONS WERE MADE DURING THE PROGRESS OF THIS SURVEY TO LOCATE BURIED UTILITIES / STRUCTURES. 3. BEFORE EXCAVATIONS ARE BEGUN, GIVE THREE WORKING DAYS NOTICE TO THE UTILITIES PROTECTION CENTER AT 1-800-282-7411 PRIOR TO ANY EXCAVATION IN ORDER THAT UNDERGROUND UTILITIES MAY BE LOCATED AND PROTECTED. 4. A 10 FOOT HORIZONTAL AND 18 INCH VERTICAL CLEARANCE SHALL BE MAINTAINED BETWEEN SANITARY SEWER LINES AND ANY WATER OR STORM LINES. WATER OR STORM LINES SHALL BE ABOVE ANY SANITARY LINES. 5. MAINTAIN A MINIMUM OF 4' OF COVER ABOVE WATER LINES. 6. ALL SANITARY SEWER LINES SHALL HAVE A MINIMUM OF 1 % SLOPE UNLESS OTHERWISE NOTED 7. FOR ANY WORK IN DOT RIGHT-OF-WAY, AN ENCROACHMENT AND/OR UTILITY PERMIT MAY BE REQUIRED. 8. ALL METERS, VALVES, AND BACKFLOW PREVENTORS ARE TO BE IN COMPLIANCE WITH THE ELIZABETH CITY REQUIREMENTS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR APPROVAL. 9. ADJUST ALL TOP OF STRUCTURES ELEVATIONS (MANHOLES, CLEANOUTS, VALVE BOXES) TO FINISH GRADE ELEVATIONS. 10. ALL SANITARY SEWER WORK MUST BE IN ACCORDANCE WITH THE ELIZABETH CITY STANDARDS AND SPECIFICATIONS. 11. LOCATOR WIRE AND DETECTOR TAPE ARE REQUIRED ON ALL SEWER LINES. SPECIAL NOTES: (D SEE MEP PLANS FOR CONTINUATION OPROPOSED LIGHTING FEATURE ° Lw r N_ N N Q M � M o O N 0 0 0 DO z O N a U U U C) O a 0. a W O S2 W O N W O_ D W Of w w O N M z non j�1tlt Htfi5144t4 20' 10, 0' 20' GRAPHIC SCALE: 1"=20'-0" Z j Z ro xM W �aM W U) � Z W 0 10'0'° °'wq m �a Z _ 2(7N� �a cli�Lu E d zo D z /\ Z) 04 z ma V W �WO9 J EL w t o <o j ED Dw 0� W a J W �U) QZ = U Q 2 ~ z a z > z m w a `� LL O O� O Q rn N p IL U) z a_ O Q O z V ` CF) a 0 W Q a z m L. D co U) J M v zz 0 � U W � J W PROJECT NO.: 16-6038 DRAWN BY: RAP DESIGNED BY: BHB SURVEYED BY: EMC SURVEY DATE: 06/03/2016 CHECKED BY: CEB SCALE: 1 "=20' DATE: 08/01 /2016 SHEET C=05 OF 19 SEWER VALVE_ 21 a M 0 r2 U 0 ro 0 m U m 0 0 co I 3 U Z U m a N W 3 m a U 3 J Q 0 I x °o n 0 I 0 NC 344 ---'" ----"" - - ------------ LqsTEAD wVI,I----- -- ------------- - - - - - -- - - - - ------------ _ CD0,T'FIBjFR6TjC box SQ TRA6I9'6GyAL PQLE' /LECTRIe'TI ANSF RME� / / _ TELEPHONE/Box 14.55 10. ITS EASEMENT p PSE K- , TB 25' LAN SCA _ 16 VD RGR017ND' `r 1 15.52 > ynb Y, BOX 6 1 > � 16 TBA� 15.6 \ Os / 50. BN� INS / 11 17.35 ' "1 16.39 O '� 17.35 1 / 1 16.59 X ' A I / c 17.15 16.51 1 t 1 \ 1 21.4 I'1 \ 1 J ` ,M i \ 17.9416.21 17.94 17.37 17.43 1 I 1 1 I I 17.48 17.33 ' _ 1 1, 1 18.00 1 / CO I , 1� I 15.7 CONTRACTOR TO PROVIDE 1 X 1 16.30 ' 1' 47.98 / h POSITIVE DRAINAGE AWAY FROM 1I' I p 17.55 - - A6 / THE ADJACENT PROPERTY o ,_' \ 1 1 O O ! \ "7 CO 20.5 IX I 1� 18.34 11,1 � . • t 1 C 10" NON -ACCESS BUFFER ' ` 1 ` 17.87 2_"3"k ` �I- 1 16.70 n 15.60 't 11 1 01 O-2.9% ) ' Z 20.4 1 all 11 ' 1 N N OOO 1 0= -3.0% x 11 11 111, 1 IQ��1 au �o� / cn- 71wi / coLL 1 'wLL 1 I 15.9 0 1 1 17.10 1 U u- I '1 -3.0 II lla 17.87 xS,p �- 1 ST 2.0 - HW "�+ x, / I •. 1 -3_y% CONC. HEADWALL 1\ 18.36 RIM:15.58 1 INV OUT:13.37 ` 16.a8 , o18.35 co �- -r 1 � 1: 1 1 ', I', 1 18.40 .�''� 17.63 '. � 6.30 I ` t 19.3 1 $11 1 ! 11'1 1 1e.00 3:U ' 13.44 1 13.37 74L.F. 18" HDPE @ 0.50% iS 14 '1 1 15.01 y 15.7 , 17.50 15.73 1416.85 .56 a. 1 16.45 16' .20 1 i 1 1 1 1 17.81 •. I r 1s.as a 1s.8e +� V ST1.0-JB 1 I JUNCTION BOX III 1 ' 1 I 19.26 t : N 15.67 RIM:17.55 I 1'1 I INV IN:13.00 lssa 17.31 I %' INV IN:12.92 1 EX INV OUT: 12.92 HPq 9.50 1 '1 t' 19.50 ' I t 16.69 1 St ' 1 ' 1 1 ' , '� \ 1 15.97 1 t 1 A - 1 18" RCP (FES) 1 INV = 12.57' 18.3 1 19.19 \ 16.47 . ., 14.66 XIS ; .., _ m r I 18.62 ` ct \\ Bll US+P 14 ` NECTION i J ------� 13.11 1 1 1 i 18.79 � - - ___ -EX.'SIpEWALK-' / S _ _ �c LAN �1GP> 'ifi------ -- -- - _ _ 8„W 8"W 18L F 18" HDPE @ 1 05% 18.36 76.3 16.2 78.0 \ 17.17 - - - 8"W ST-3.0 - FES a CTrAC TRANSFORMER - - - _ - _ 1ASPHALT RIM:15.17 16.3 FLARED END SECTION I . 6.6 Y S - ^ -EX° 5°E� pATRlciz,W INV OUT:13.11 17.2 '8" PVC 6.8 8"W ' _ _ _ _ PAVING, GRADING, AND DRAINAGE NOTES 1. ENTIRE SITE SHALL BE DRESSED TO UNIFORM, WELL DRAINED AND VISUALLY APPEALING SURFACE WITH A MINIMUM TOPSOIL LAYER OF FOUR INCHES. 2. MAXIMUM LONGITUDINAL SLOPE ON ALL ACCESSIBLE SIDEWALK SHALL BE 5.00%. 3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THE SITE IS ADA ACCESSIBLE AS REQUIRED BY FEDERAL, STATE AND LOCAL GOVERNMENT. 4. FINISH GRADE SPOT ELEVATIONS INDICATE TOP OF PAVEMENT / FACE OF CURB UNLESS OTHERWISE NOTED. 5. REFER TO DETAILS FOR PAVEMENT TYPICAL SECTION. 6. SITE SHALL BE GRADED UNIFORMLY FOR POSITIVE DRAINAGE AS SHOWN FROM THE ELEVATIONS, PROPOSED CONTOURS, AND THE DRAINAGE SLOPE ARROWS. 7. MAXIMUM SIDEWALK CROSS SLOPE IS 2%. MAXIMUM SIDEWALK LONGITUDINAL SLOPE IS 5%. MAXIMUM PAVEMENT SLOPE IN HANDICAP PARKING AREA AND AISLE IS 2%. MAXIMUM HANDICAMP RAMP SLOPE IS 12HAV. UTILITY NOTES: 1. THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES AS SHOWN HEREON ARE BASED ON ABOVE -GROUND STRUCTURES AND IS APPROXIMATE AND SHOWN FOR INFORMATIONAL PURPOSES ONLY. NO CERTIFICATION IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE THIS INFORMATION. 2. ADDITIONAL BURIED UTILITIES / STRUCTURES MAY BE ENCOUNTERED. NO EXCAVATIONS WERE MADE DURING THE PROGRESS OF THIS SURVEY TO LOCATE BURIED UTILITIES / STRUCTURES. 3. BEFORE EXCAVATIONS ARE BEGUN, GIVE THREE WORKING DAYS NOTICE TO THE UTILITIES PROTECTION CENTER AT 811 PRIOR TO ANY EXCAVATION IN ORDER THAT UNDERGROUND UTILITIES MAY BE LOCATED AND PROTECTED. HATCH LEGEND: I I d d SPECIAL NOTES: CONCRETE PAVEMENT EXISTING CONCRETE (D PROVIDE SMOOTH TRANSITION TO EXISTING GRADE PROPOSED CONCRETE o Z O H a 0 W 0 U) a a a W U U U Z m m O a a a W d' o n w _0 T w O_ /n w Z N C f}�t '71ra � t � API �3 { /Fill 1ZAA 4, t i it t �a 20' 10, 0' 20' Emommmmmoni GRAPHIC SCALE: V=20'4' Uto Z =� i W - �<M 3 W O o N ZW rn Inm6 YO W - m N U cl N co), U coZ - S CO N ,-. E Z p /\ It�- m N J Z Z) 'i' �@ c W o Z N V �Waw o� o `�r'w m �m W C Om C � w Q ~ Q W J W J Z = O w ¢ z Z >> 0 Z< m w Q `� LL Lu Z 0 Q `" IL LU a a J C9 Z a ? a o Y 0° ,Z^ Q U_ V 0 V W M a L F- Z a Z C" o a N J M V O Q 0 Z M� W = ~ N a w PROJECT NO.: 16-6038 DRAWN BY: RAP DESIGNED BY: BHB SURVEYED BY: EMC SURVEY DATE: 06/03/2016 CHECKED BY: CEB SCALE: 1 "=20' DATE: 08/01 /2016 SHEET C=06 OF 19