Loading...
HomeMy WebLinkAboutSW7090811_HISTORICAL FILE_20210728STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW -i�1I��� v DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2(22 142 7,,qr' YYYYMMDD ROY COOPER Governor ELIZABETH S. BISER Secretary BRIAN WRENN Director NORTH CAROLINA Envfrotunental QuaUty July 28, 2021 East Carolina University Attention: William E. Bagwell, Associate Vice Chancellor 1001 East 4th Street Mail Stop 209 Facilities Services Greenville, NC 27858 Subject: Stormwater Permit Renewal Stormwater Management Permit SW7090811 ECU — Grounds Complex Relocation Pitt County Dear Mr. Bagwell: ua po A Division of Energy, Mineral, and Land Resources file review has determined that Stormwater Permit SW7090811 for a stormwater treatment system consisting of a wet detention pond serving the ECU Grounds Complex Relocation located on W. Arlington Blvd in Greenville, NC expires on December 29, 2021. This is a reminder that permit renewal applications are due 180 days prior to expiration. We do not have a record of receiving a renewal application. Please submit a completed permit renewal application along with a $505.00 fee for permit renewal. Permit application forms for renewal can be found on our website at: https://deq. nc.gov/about/divisions/energy-m ineral-and-land- resources/stormwater/stormwater-program/post-construction-2. North Carolina General Statutes and the Coastal Stormwater rules require that this property be covered under a stormwater permit. If you have questions, please feel free to contact me at (252) 948-3923. 1 will be glad to discuss this by phone or meet with you. If you would like, I can e-mail you a copy of the application forms. You can request a copy by e-mailing me at roger.thorpe()ncdenr.gov. Sincerely, <L. 0v Roger K. Thorpe Environmental Engineer North Carolina Department of Environmental Quality i Division of Energy, Mineral and Land Resources Washington Regional Office 1943 Washington Square Mall I Washington, North Carolina 27889 uoam cNnuua 252.9466481 s DWQ`LJSE':ON>LY."- $'- aX:': ,Date Received Fee Paid Permit Number State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original 1. GENERAL INFORMATION 1. Applicants name (specify the name of the corporation, individual, etc. who owns the project): 2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance): 3. Mailing Address for person listed in item 2 above: East Carolina University, Facilities, Engineering & Architectural Services City: 1001 East Fourth Street State: NC Zip: 27858-4043 Phone: (252 ) 328-6858 Fax: (252 ) 328-4259 Email: bagnellw@ecu.edu 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): East Carolina University Grounds Complex Relocation 5. Location of Project (street address): W. Arlington Boulevard City: Greenville County: Pitt 6. Directions to project (from nearest major intersection): Driving east on NC Highway 43, turn right on W. Arlington Boulevard. The site is located approximately 1000 LF from NC Highway 43. 7. Latitude:35° 36' 51" N Longitude:77° 24' 41" W of project 8. Contact person who can answer questions about the project: Name: R. Todd Fisher, PE Telephone Number: (919 ) 719-1800 Email: tfisher@colejeneststone.com II. PERMIT INFORMATION: 1. Specify whether project is (check one): s. ❑Renewal ❑Modification FormSWU-101 Version09.25.08 Page I of 2.' If this application is being submitted as the result of a renewal or modification to an existing permit, list the existing permit number N/A and its issue date (if known) N/A 3. Specify the type of project (check one): ❑Low Density ®High Density ❑Redevelop []General Permit ❑Universal SMP ❑Other 4. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑LAMA Major ®Sedimentation/Erosion Control ❑404/401 Permit ❑NPDES Industrial Stormwater III. PROJECT INFORMATION 1. In the space provided below, summarize how stormwater will be treated. Also attach a detailed narrative (one to two pages) describing stormwater management for the project. East Carolina University is planning to build an parking and store area to relocate their grounds equipment. The stormwater will be treated using a wet detention basin The BMP chosen because of the peak flow attenuation and the pollutant removal. Bioretention cannot be used because of the lack of elevation change across 2. Stormwater runoff from this project drains to the Tar Pamlico River basin. 3. Total Property Area: 6.99 acres 4. Total Coastal Wetlands Area: 0.00 acres 5. Total Property Area (3) — Total Coastal Wetlands Area (4) - Total Project Area**:6.99 acres 6. (Total Impervious Area / Total Project Area) X 100 = Project Built Upon Area (BUA):55.3 % 7. How many drainage areas does the project have?4 8. Complete the following information for each drainage area. If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. For hieh densitv oroiects, complete the table with one drainage area for each engineered stormwater device. Basin Information Drainage Area 1 Drainage Area 2 Receiving Stream Name UT to Sandalhouse Branch UT to Sandalhouse Branch Stream Class & Index No. Jurisdictional Jurisdictional Total Drainage Area (sf) 101495 96703 On -site Drainage Area (sf) 101495 96703 Off -site Drainage Area (sf) 0 0 Existing Impervious* Area (sf) 0 0 Proposed Impervious*Area (sf) 81021 ✓ 77362 (future) Impervious* Area (total) 79.8 80.0 Impervious* Surface Area Drainage Area 1 Drainage Area 2 On -site Buildings (sf) 9714 ✓ 9500 On -site Streets (sf) 0 0 On -site Parking (sf) 69012 J 67862 On -site Sidewalks (sf) 2296 ✓ 0 Other on -site (sf) 0 0 Off -site (sf) 0 0 Total (sf): 81021 J 77362 Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. **Total project area shall be calculated to exclude Coastal Wetlands from use when calculating the built upon area percentage calculation. This is the area used to calculate overall percent project built upon area (BUA). Form SWU-101 Version 09.25.08 Page 2 of ,Basinlnformation ' D'rainageArea3 yp.:,.'; UT to Sandalhouse Branch jDrainage:Area.4::::,' Receiving Stream name~ UT to Sandal house Branch Stream Class & Index No. Jurisdictional Jurisdictional Total Drainage Area (sf) 18731 231,739 On -Site Drainage Area (sf) 1770 63936 Z(e3,g1 Off -site Drainage Area (sf) 16961 167803 Existing Impervious Area (sf) 0,---, , 0 Proposed Impervious Area (sf) r10019 Y 0 % Impervious Area (total) �-53.5 0 �IinpervA!a0Sufface Area`" °Drainage A[ea,3 'Drainage�Arei*' ' On -site Buildings (sf) 0 0 On -site Streets (sf) 10019 0 On -site Parking (sf) 0 0 On -site Sidewalks (sf) 0 0 Other on -site (sf) 0 0 Off -site (sf) 0 0 Total (sf) 10019 ✓ 0 Propo�,e d BLfA ro oiei v5 1770 on srFc DA 7 r 9. How was the off -site impervious area listed above derived? Projects in Union County: Contact the DWQ Central Office staff to check to see if you project is located within a Threatened & Endangered Species watershed that may be subject to more stringent stormwater requirements. IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS One of the following property restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment. Forms can be downloaded from httj2://h2o.enr.state.nc.us/sufbml2 forms.htm - deed restrictions. Form DRPC-1 High Density Commercial Subdivisions Form DRPC-2 High Density Developments with Outparcels Form DRPC-3 High Density Residential Subdivisions Form DRPC-4 Low Density Commercial Subdivisions Form DRPC-5 Low Density Residential Subdivisions Form DRPC-6 Low Density Residential Subdivisions with Curb Outlets By your signature below, you certify that the recorded property restrictions and protective covenants for this project shall include all the applicable items required in the above form, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DWQ, and that they will be recorded prior to the sale of any lot. V. SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project. Contact the Stormwater Permitting Unit at (919) 807-6300 for the status and availability of these forms. Forms can be downloaded from http://h2o.enr.state.nc.us/su/bmp forms.htm. Form SW401-Low Density Form SW401-Curb Outlet System Form SW401-Off-Site System Form SW401-Wet Detention Basin Form SW401-Infiltration Basin Form SW401-Infiltration Trench Form SW401-Bioretention Cell Form SW401-Level Spreader Form SW401-Wetland Form SW401-Grassed Swale Form SW401-Sand Filter Form SW401-Permeable Pavement Form SW401-Cistern Low Density Supplement Curb Outlet System Supplement Off -Site System Supplement Wet Detention Basin Supplement Infiltration Basin Supplement Underground Infiltration Trench Supplement Bioretention Cell Supplement Level Spreader/Filter Strip/Restored Riparian Buffer Supplement Constructed Wetland Supplement Grassed Swale Supplement Sand Filter Supplement Permeable Pavement Supplement Cistern Supplement Form SWU-101 Version 09.25.08 Page 3 of VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Office. (Appropriate office may be found by locating project on the interactive online map at httn:Hh2o.enr.state.nc.us/su/msi maos.htm) Please indicate that you have provided the following required information by initialing in the space provided next to each item. In' 'als • Original and one copy of the Stormwater Management Permit Application Form • Original and one copy of the Deed Restrictions & Protective Covenants Form (if to. required as per Part IV above) • Original of the applicable Supplement Form(s) and O&M agreement(s) for each BMP WIu- fjpA;k/r AT A LA�Tpo- • Permit application processing fee of $505 (Express: $4,000 for HD, $2,000 for LD) payable to NCDENR • Calculations & detailed narrative description of stormwater treatment/management • Copy of any applicable soils report • Two copies of plans and specifications (sealed, signed & dated), including: n/11 - Development/Project name - Engineer and firm -Legend - North arrow - Scale - Revision number & date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations - Drainage areas delineated - Vegetated buffers (where required) VII. AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf (such as additional information requests), please complete this section. (ex. designing engineer or firm) Designated agent (individual or firm): Colelenest & Stone Mailing Address: 150 Fayetteville Street, Suite 950 City: Raleigh State: NC Zip: 27601 Phone: ( 919 1 719-1800 Fax: (_ 919 ) 719-1819 Email: +��shct•� cok�cnes�s�e•�ca� VIII. APPLICANT'S CERTIFICATION I, (print or type name of person listed in General Information, item 2) William E. Bagnell certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A NCAC 2H .1000. Date: 5 _ I r - 07 Form SWU-101 Version 09.25.08 Page 4 of 4 Permit No. (to be pmvrdad by DWQ) pA MCDENR Project name Contact person Phone number Date Drainage area number STORMWATER MANAGEMENT PERMIT APPLICATION FORM 401 CERTIFICATION APPLICATION FORM WET DETENTION BASIN SUPPLEMENT This form must be filled out, printed and submitted. The Required Items Checklist (Part 111) must be printed, filled out and submitted along with all of the required information. =OF W ATegOG T , r o Drainage area 198,198 fe Impervious area, post -development I 158,3831 ftz % impervious 79.91 % Design rainfall depth 1.01 in Storage Volume: Nan -SA Waters Minimum volume required 12,718 @3 ✓ OK Volume provided 15,246 k3 ✓ OK, volume provided Is equal to or in excess of volume required. Storage Volume: SA Waters 1 5' runoff volume Pre -development 1-yr, 24-hr runoff Post -development 1-yr, 24-hr runoff Minimum volume required Volume provided Peak Flow Calculations Is the pretpost control of the lyr 24hr storm peak flow required? 1-yr. 24-hr rainfall depth Rational C, pre -development Rational C, post -development Rainfall intensity: 1-yr, 24-hr stone Pre -development 1-yr, 24-hr peak flow Post -development 1-yr, 24-hr peak flow PrelPost 1-yr, 24-hr peak flow control Elevations Temporary pool elevation Permanent pool elevation SHWT elevation (approx. at the perm. pool elevation) Top of 10f1 vegetated shelf elevation Bottom of 10ft vegetated shelf elevation Sediment cleanout top elevation (bottom of pond) Sediment cleanout, bottom elevation Sediment storage provided Is there additional volume stored above the state -required temp. pool? Elevation of the top of the additional volume Y 1(Y or N) 3.11 in 0.151 limitless) f-0.791 limitless) 1 5.281 irdhr OK 1.58 fl'lsec ✓ 0.38 ft'Isec RV = 0, cb + a. 9 i A 12v as + d• �Sv/rue, Q✓ 3 .72 t V - 36 3o 72) (4, SS) //, 6qo ± Q= ':�.d A 2 N o -1 20 tt'Isec = Cd (trr R 2) 2q 32.001first ✓ _ ,G (3,)4 1,5)2 2�32.Zx•33� 31.00Ifmsl I Z I 30.00-31.001 first ✓ 1 I 31.501 first ,r,)(4./V(.15W (Q •L� = 1,35 I 30.501 fmsl Data not needed for calculation option #1, but OK If provided. I 25.001 fmsl ✓ I 24.0D firsl Data not needed for calculation option #1, but OK if provided. 100 It Y I(Y or N) 32.0 fmsl OK Fonn SW401-Wet Detention Basin -Rev 6-220109 9 Pans I a II Design Summary, Page 1 of 3 Permit No. (to t>e Pmvoed by DWQ) I14DESIGKINF,ORMATION Surface Areas Area, temporary pool 16,984 fe Area REQUIRED, permanent pool SAIDA ratio 8,919fe r ,r �4:50 (unitless) / ✓ sa D� ��y� X Area PROVIDED, permanent pool, A._,, 01 ft` OK 700 Area, bottom of 10ft vegetated shelf, Av,_v„r'm11;355�ft' CC _ �aQ (�'8 X Area, sediment deanout, top elevation (bottom of pond), A,,y, ',« F 2;27,7�ft` J O Volumes Volume, temporary pool W _ 5,246 ft' OK / ,S O +f Z •f Volume, permanent pool, V. . Volume, fombay (sum of forebays ifmore than one forabay) ',', •'^ :'8;3151 k' T 55 / �j y / Q� % 13cA Forabay % of permanent pool volume 20.0% % OK �b �, SAIDA Table Data Design TSS removal ✓ _ _% Coastal SAIDA Table Used? f ., 'N,„;' (Y or N) MountaindPiedrrc nt SAIDA Table Used? (Y or N) SAIDA ratio 4.50 (unifless) Average depth (used in SAIDA table). Calculation option 1 used? (See Figure 10-2b) (Y or N) Volume, permanent pool, Vp _p, , --'.; $1=:� 41;556 ft OK Area provided, permanent PooI. A.�m2„Q4,_1.0 W OK Average depth calculated I-""`3'16ft OK Average depth used in SAIDA, d„, (Round to nearest 0.5ft) _,-;j "L3_0) ft OK Calculation option 2 used? (See Figure 10-2b) (Y or N) Area provided, permanent pool, A.. ."_�.; — ' ft` Area, bottom of 10ft vegetated shelf, A.,,,,, •,�>.�%'Wfy, „k` Area, sediment deanout, top elevation (bottom of pond), A,.a 'Depth' (distance b/w bottom of 10f shelf and top of sediment) Average depth calculated Average depth used in SAIDA, d„, (Round to nearest 0.5ft) Drawdown Calculations Drawdown through onfce? Diameter of orifice (if circular) Area of orifice (if -non -circular) Coefficient of discharge (Co) Driving head (Ha) Drawdown through weir? Wen type Coefficient of discharge (C.) Length of weir (L) Driving head (H) Pre -development 1-yr, 24-hr peak flow Post -development 1-yr, 24-hr peak flow Storage volume discharge rate (through discharge onfce or weir) Storage volume drawdown time Additional Information Vegetated side slopes Vegetated shelf slope Vegetated shelf width Length of flowpath to width ratio Length to width ratio Trash rack for overflow & odfce? Freeboard provided Vegetated filter provided? Recorded drainage easement provided? Capures all runoff at ultimate build -out? Drain mechanism for maintenance or emergencies OK OK OK, draws down in 2-5 days. OK, dmwdown time is correct. :1 OK ✓ 1 OK ✓ ft OK ✓ :1 OK 1 OK ✓ (Y or N) OK It OK (Y or N) OK (Y or N) OK (Y or N) OK L'. Form SW401 Met Detention Basin -Rev S-W/20109 Parts I a H Design summary, Page 2 of 3 Permit be provided by DWQ) Ill. REQUIRED'ITEMS'CHECKUST Please indicate the page or plan sheet numbers where the supporting documentation can be found. An incomplete submittal package will result in a request for additional information. This will delay final review and approval of the project. Initial in the space provided to indicate the following design requirements have been met. If the applicant has designated an agent, the agent may initial below. If a requirement has not been met, attach justification. Page/ Plan Initials Sheet No. CV K, D 1 Plans (1"- 50' or larger) of the entire site showing: - Design at ultimate build -out, - Off -site drainage (if applicable), - Delineated drainage basins (include Rational C coefficient per basin), - Basin dimensions, - Pretreatment system, - High Flow bypass system, - Maintenance access, - Proposed drainage easement and public right of way (ROW), - Overflow device, and - Boundaries of drainage easement. Aa t o 2. Partial plan (1" = 30' or larger) and details for the wet detention basin showing: GV 8.6 - Outlet structure with trash rack or similar, CV19. - Maintenance access, - Permanent pool dimensions, - Forebay and main pond with hardened emergency spillway, - Basin cross-section, - Vegetation specification for planting shelf, and - Filter strip. (� _.bNrr cv�s. 3. Section view of the wet detention basin (1" = 20' or larger) showing: - Side slopes, 3:1 or lower, - Pretreatment and treatment areas, and - Inlet and outlet structures. 4. If the basin is used for sediment and erosion control during construction, clean out of the basin is specified on the plans prior to use as a wet detention basin. i�ALC. 5. A table of elevations, areas, incremental volumes & accumulated volumes for overall pond and for Forebay, QkKilil to verify volume provided. a 3.1 6. A construction sequence that shows how the wet detention basin will be protected from sediment until the entire drainage area is stabilized. [�_ 7. The supporting calculations. WK04E 101" fiF S cNr, 8. A copy of the signed and notarized operation and maintenance (0&M) agreement. y' ( — 9. A copy of the deed restrictions (if required). A • r_ iA� L , 10, A soils report that is based upon an actual field investigation, soil borings, and infiltration tests. County WKill soil maps are not an acceptable source of soils information. Form SW401-Wet Detention Basin-Rev.6-2/20/09 Part III, Required Items Checklist, Page 3 of 3