Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW7071115_APPROVED PLANS_20171106
STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 4U2�9� Qll zza( YYYYMMDD NOTES' 1. OWNER/DEVELOPER: I.G. HOLDINGS, LLC. P.O. BOX 120 10. PARKING HAS BEEN CALCULATED AS FOLLOWS: 14. THERE ARE NO ADDITIONAL SITE LIGHT FIXTURES PROPOSED. THE DWELLING WILL KITTY HAWK, NC 27949 1 SPACES/200 SF GROSS FLOOR AREA FOR EXISTING RETAIL HAVE TRADITIONAL PORCH LIGHTS. PHONE: 252-480-0009 12,427 SF/ 200 = 62.1 SPACES REQUIRED 1 SPACE/BEDROOM FOR PROPOSED RESIDENCE 15. STORMWATER MANAGEMENT WILL BE TO THE EXISTING INFILTRATION BASIN AND A 2. THE OWNER INTENDS TO CONSTRUCT A SECOND 4 BEDROOM SINGLE FAMILY 4 BEDROOMS, EXISTING = 4 SPACES REQUIRED LEVEL SPREADER. RESIDENCE AND SEPTIC SYSTEM ON THE EXISTING SITE. 4 BEDROOMS PROPOSED = 4 SPACES REQUIRED TOTAL: 70.1 SPACES REQUIRED; 71 SPACES PROVIDED 16. THE OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL BUFFERING. 3. THE PROPERTY IS RECORDED IN DEED BOOK 1752, PG. 35. ALL REQUIRED LANDSCAPING AND BUFFER AREAS SHALL BE MAINTAINED IN GOOD DARE COUNTY PIN# 0640 17 22 1119. 11. ALL DISTURBED AREAS SHALL BE STABILIZED WITH A COASTAL VEGETATION MIX. CONDITION SO AS TO PRESENT A HEALTHY AND ORDERLY APPEARANCE AND SHALL PROPERTY ADDRESS: 40494 NO HWY 12, AVON, DARE COUNTY, NC. AREA TO BE DISTURBED = 7,069 SF (0.16 ACRES) BE KEPT FREE FROM REFUSE AND DEBRIS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE REPLACEMENT OF PLANTS DAMAGED BY INSECTS, DISEASE, VEHICULAR 4. THE PROPERTY IS ZONED GENERAL COMMERCIAL DISTRICT (C-2) AND THIS WILL 12. LOT COVERAGE IS AS FOLLOWS: TRAFFIC, AND VANDALISM. BE A CONDITIONAL USE. EXISTING COVERAGE 17. ALL NEW UTILITIES ARE TO BE PLACED UNDERGROUND. FINAL DRAWING 5. THE SITE IS LOCATED IN FIRM ZONE AE 8', RETAIL BUILDING 12,575.6 SF 18. NO SIGNS FOR THIS USE WILL BE ERECTED. FIRM MAP NUMBER 3730064000J, EFFECTIVE DATE SEPTEMBER 20, 2006. RESIDENCE 2,079.1 SF (SUBJECT TO CHANGE BY FEMA) PAVEMENT 29,590.3 SF NOT FOR SIDEWALKS 3,970.1 SF 19. THERE ARE NO DELINEATED WETLANDS ON THIS SITE. 6. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE TANK COVERS 178.3 SF 20.THE PROPOSED DWELLING WILL BE A 1 OR 2 STORY DWELLING, ELEVATED ON SPECIFIED. ELEVATIONS SHOWN ARE HEREON PER NAVD88. HVAC STAND 6.1 SF WOOD PILINGS APPROXIMATELY 4.5'-5.0' FROM THE EXISTING GRADE (AS NEEDED 48,399.5 SF 7. AREAS SHOWN ARE BY COORDINATE METHOD. TO MEET DARE COUNTY FLOOD DAMAGE PREVENTION ORDINANCE) AND SHALL NOT CONSTRUCTIONPROPOSED COVERAGE EXCEED THE MAXIMUM ALLOWABLE HEIGHT OF 52'. 8. TOTAL AREA = 125,779 SF (2.88 ACRES) NEW RESIDENCE 1,994.8 SF AREA OF CANAL = 5,438 SF (0.12 ACRES) NEW PAVEMENT 680.8 SF 21. SEEDING AND EROSION CONTROL SHALL BE ESTABLISHED WITHIN ANY DISTURBED UPLAND AREA = 120,341 SF (2.76 ACRES) NEW TURFSTONE 400.0 SF AREAS. TOTAL COVERAGE 51,475.1 SF (42.8%) (UPLAND AREA) 9. MINIMUM BUILDING SETBACKS: 22. THE EXISTING IRRIGATION WELLS ARE TO BE ABANDONED IN ACCORDANCE WITH FRONT 15' COVERAGE ALLOWED 72,205 SF (60.0%) (UPLAND AREA) STATE REGULATIONS. IF NEW IRRIGATION WELLS ARE TO BE INSTALLED, THEY REAR 20 SHALL COMPLY WITH ALL APPLICABLE STATE MANDATED SETBACKS. SIDE 10' 13. TOTAL IMPERVIOUS AREA WITHIN 75' AEC: 0.0 SF (0.0 %) WCMTYMAP N/F JG11N GRAY GRANTE GRAY D6 244, PG 514 INSTALL NEW 0640 17 IZ 7364 5.9 / PARRKGN PACES / _ INSTALL N� DROP CURB A KAY CHAPLAIN GMFu4 / (NCDOT 84-8.02) / PARCEL ONE -THREE / INSTALL NEW CONCRETE P.G. ff �- 191 PARKING SPACES D6 746, PG 544 _ 0640 17 22 45-n -227 • S86'13'09"E 656.75' b III ' n SEPTI REPAIR AREA _�� / / / N 740 SF _ JAMES GHAPAS / -_.. ;Li �� Sig - RObERTA G1APA5 / / ' �2� � SEPTIC REP R AREA LOT' l!, PRICE / tar 9 {I I 720 SF 5.15 TC E16111V5 ACTIVE SEPTIC A< --A.' SUBDIVISION / / IB1 527 �i ` n4o � 56s sa 5s sa st l f PC. G, 5L. 66G / I T eo N bs bg a55 Tl . Gf-_ 517 529 b* 9A bb Pp 080, PG 5 / � 9fJ89 298 •. __ __'__'�,6k'^--..-.-. � 5y 597.', 547 559 5b8 5.77 5 � � 00 0640 17 IZ 72o for __ �9. Q • f� Fob sa _ 5.94 57a s59 less 1 �.' / 5T5 579 552 1547. 15%G O �870 P PROPOSED ACTVE SEPTIC AREA 6$ 95 ram.. , GC1'7GR�E f� bjla 4 BEDROOM 't < y PARKR46 Li NMDIGAP PARKM6 e & DWELLING sew ngMED 6N 1 5A -' SI 1542 1559 57i 5914 4 3 14 / 2. FFE = 11.0' 5 6 (2,000 SF MAX.) 471 / I 612 G.9'i 655 -6.75 IXIYDIN6 GLLIMY'. 8 / Z50 - 4b -s$" i.56? 1 Ab 658. 4 625 / SEPTIC REPAIR ' - i / I bPJ 1 551 5T COT k.11 AREA NEW 30 /; r W _ 75/ I i5b2 1,000 GALLON 736 SF AHRAINFlELD ° _4,04 -I �.� _ 19`All-4�._L. p. h' II Ip 'g _ I I 5 � 5 SEPTIC TANK sue- 3 Rf 'C • �95 525 �� b 5 4 ,� 2 j 7 �3$7 �` tRVK a PAVERS kb0 , bd0, - _ c g:: -' �- - m- // �1 / CTIVE SEPTIC AREA 45 ItnI�67... l Y. 4� M �F N/P / 2 2.53 in 44 SION / LLLA MAE PRICE I� / �� , Fxsred5 -� sb' S8 bn9 �� / LOF k, PRICE 2 Q 29n �T� rArtc srArD F ISs aE�ocATEo' SUBDIVISION - srazrnwnraz _ _ _ _ _ _ Y: •» DRAINFIELD 'SA w PL. G, SL. 66G l �` �� 1 / tnsM baa e - 4k7 4 DB 616, PG 484 sl utv 0640 7 (2 642 / `� / ,r2o _ I @ OIJE STORY DN�LLIN6 I --A3a -g- I' ''o''s -- TWO STORY FRAME ILDNMETAL I '� ��o� ! I R PFE. = ILI' II r 0 BU G 1 A] i0- 3 ON CONCRETE SLAD � f ROOF I -- k30 , -¢56 FFE. ' I I - / `' = S � i as 5 2 °ry I I 295b _ I k25 -4�5 2v I I6 8 , • / I \60Tb , _ _ 57 i RFP7k / 2�& A71 M�_� '�9 4YO �� --_ :' S�2 200 OVSt!'IMG BU.1t1£iD �� 9.9�' �� 2 �� Z. DOT- 26b7 -297�r �� 2 .. (All LOT 5 PRICE � / 1 k80 tOT .. �- m {YiG..e.. , .. ..... _ 4� .. - - �S _ �/ .��� ��e e�ac .gym• ��o. �o__��e .�n_�� >�.... �4' / (IRS S16pIV1510N ZAO 3y ..,..�rON ..... �.., k� �4� m kb9 �.. J� �I ��_o• �g5 9 _- - - __ 5 17PJ F� w 5L. 66G DB 616, PG 492 469 W wNil" r w w-- 0640 17 IZ 6OZ5 2.11 ( cr2T S88'DO'34'W 666.15 CONNECT TO - COORDINATE WITH UAI F- 56Rff]� EX. WATER SERVICE TO LOCATE EX. WATE , RM"TER PAD / 163 OO _ PIN _ 9 SERVICE F/tLKMOGO LLt'i N/F F N/F PROPOSED SITE A40D CATIONS I PL. E, SL 769 ° l 'a, DENNIS WILLIAMS / / ANN SCALE: 1" = 30' I PIP14M, PG ISS { B 1013, P 16 ' DB 'G76PG 549 0, 0640 17 22 9001 D/ - - - 640 II1 17 700916 / 0640 17 11 99N / u / / W. W4 I 2A2 �• Rw zl W. wo 0 • -227 • 1. THE DESIGN FLOW FOR THE SYSTEM IS S86'13'09"E 656.75' • v (4 BEDROOM) X (120 GPD) = 480 GPD DRAINFIELD AREA (BED SYSTEM) 454 (480 GPD) (1 SF/1.0 GPD) (1.5) = 720 SF -_ --_ �290 I Si REPAIR „nr:n 2. A 1,000 GALLON TRAFFIC RATED SEPTIC TANK WITH EFFLUENT FILTER AND A MINIMUM OF • I uM I 49 5a -` 240 LF OF GRAVITY DRAINFIELD WILL BE PROVIDED FOR EACH SYSTEM. A LOADING OF 1.0 Car j f76o EXI5TII46 AG740 ` TIC p�4 IBI OF DISTURBANCE 1140 565 • 5z7 / I - I11 GPD/SF HAS BEEN APPLIED. • // REMOVE PORTION „..... 40 517 5 vr 2 3 OF DOSTING zb 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL NOTIFY ULOCO PRIOR TO to ( CURB & GUTTER ♦.506 CONSTRUCTION (2 WORKING DAYS). � "M® 4. HORIZONTAL AND VERTICAL ORIENTATION OF EXISTING UNDERGROUND UTILITIES ARE NOT -B5 • 1 "' fin gi GUARANTEED. THE CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF ALL EXISTING UTILITIES EXISTING DRAINFlELD z 454 I I 45 ev - B1 542 ev5 PRIOR TO COMMENCEMENT OF CONSTRUCTION. . TO BE REMOVED 2t EE5 5�z 290 I ACT I I I k71 5b9 5. THE CONTRACTOR SHALL SUBMIT A LIST OF MATERIALS FOR APPROVAL TO THE ENGINEER • �eor all I 4 �9 A69 5 p PRIOR TO COMMENCEMENT OF CONSTRUCTION, IF REQUIRED. 195 I - 6. ROUTINE INSPECTIONS DURING CONSTRUCTION WILL BE PROVIDED BY THE ENGINEER AND • 487 /525 I I I k6p 'A 25 bOYJ < _ �_ DARE CO. HEALTH DEPARTMENT. THESE INSPECTIONS DO NOT RELIEVE THE CONTRACTOR 4r0a FROM HIS OBLIGATION AND RESPONSIBILITY FOR CONSTRUCTING THE SYSTEM IN STRICT ,�• ,I 92 27 ACCORDANCE WITH THE PROJECT PLANS AND SPECIFICATIONS, IF REQUIRED. _ J 455 r4 29� '- J �N I 44 461 H 7. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES, 26 REGULATIONS AND ORDERS OF ANY AGENCY HAVING JURISDICTION. HE SHALL ERECT AND �Tn 455 qn V, TANG 459 ' MAINTAIN, AS REQUIRED BY THE CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY eT RkM� i I wr - _ - - _ 40 54 SAFEGUARDS FOR SAFETY AND PROTECTION. PAIkA2 5m 29�a I is 64,i 4Z -495 2.1 S. NO MODIFICATIONS TO THIS PLAN SHALL BE MADE WITHOUT THE PRIOR APPROVAL OF THE 20 POT ONE STORY DWELLING 4'� - V5 u - ENGINEER AND LOCAL HEALTH DEPARTMENT. ANY FIELD CHANGES TO THE PLANS SHALL BE I R FFE. = 11. - 451 511 Z7 APPROVED BY THE ENGINEER AND COUNTY HEALTH DEPARTMENT AND SHALL BE ACCURATELY r _ 41 x 27 - INDICATED ON THE AS -BUILT DRAWINGS. - -2.9z9 / -z156 �I. OVER11AW I 2.y%q k50 `� 9. ALL MANHOLE RISERS SHALL BE PRECAST CONCRETE, WATERTIGHT, CONFORM TO NORTH sob to D22 7 CAROLINA CODE 15A NCAC 18A-1954 AND BROUGHT TO FINISHED GRADE BY CONTRACTOR, _ _ _ 4z5- - _ . 445 UNLESS OTHERWISE NOTED. 4.71. 4w ~ 10. ALL GRAVITY SEWER BENDS 45' OR GREATER SHALL BE FITTED WITH A CLEAN -OUT. INV. °,612 I 22ak tar 9 2 ZBAb 29L9 11. ALL SEPTIC COMPONENTS SHALL BE LOCATED A MINIMUM OF TEN FEET FROM EXISTING AND 4a� ea 4 2_1fb7 29790r . ..... - PROPOSED WATERLINES. wr m,......e..�„ ...m oar- - - - Mr m . 494 �_ 4219 495 469 12. ALL COMPONENTS OF THE SYSTEM SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH z51- 4� THE CONTRACT DRAWINGS, SPECIFICATIONS, AND THESE PLANS. AFTER TESTING IS COMPLETED w w w AND ALL COMPONENTS OF THE WASTEWATER SYSTEM ARE ACCEPTED BY THE OWNER, THE _ 2I1 w CONTRACTOR SHALL SUBMIT AS -BUILT DRAWINGS TO DARE COUNTY HEALTH DEPARTMENT ANY ,RIM 5A5 D DISCREPANCIES NOTED DURING INSPECTION OF THE AS -BUILT FACILITIES SHALL BE ssaoo'3aw s66.15' IN 2 CORRECTED BY THE CONTRACTOR WITHIN 30 DAYS IF NECESSARY. W. im (VJ) RTPSTER PAP CVNI 13. ALL DISTURBED SOIL SHALL BE STABILIZED AS SOON AS POSSIBLE BY GRADING AND wI 415 I QWHIC SCALE SEEDING. Mv. ub W I 0 15 30 60 14. THE CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS TO A CONDITION EQUAL TO OR W 2,% M BETTER THAN THOSE EXISTING PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. THE INV. a,91 (sM EXIS%%�K� (PARTIAL SITE) AND DEMOIJTIOIV PLAN OWNER RESERVES THE RIGHT TO STOP WORK IF AND WHEN, IN THE SOLE OPINION OF THE SCALE: 1" = 30' OWNER, CLEANUP, RESTORATION OR PUBLIC SAFETY ARE NOT BEING PERFORMED IN (IN FEET) ACCORDANCE WITH THE CONTRACT DOCUMENTS. 1 INCH = 30 FT. REFER TO PERMIT FC FILL REQUIREMENTS FILTER FABRIC TREVIRA SPUNBOND 1112 OR AMOCO 2090 c>' w 550 NORTHG'ZC'vAE 'ENT,AL r r AC2rnENT C _ ON Dcte /� 16 �o l7 o l 1 115 EmSECTION 6-40' LINES 03'OC NTS CLEAN WASHED #5 GRANITE AGGREGATE GRADE TO DRAIN R/W CONCR-E MONUMENT IRON PIPE FOUND IRON ROD FOUND IRON ROD SET PK NAIL FOUND PK NAIL SET CONCRETE MONUMENT FOUND CABLE TV PEDESTAL TELEPHONE PEDESTAL LIGHT POLE UTILITY POLE GUY WIRE OVERHEAD UTILITY LINE RIGHT OF WAY FENCE STORM PIPE DRAIN BASIN DROP INLET JUNCTION BOX WATERLINE FIRE HYDRANT WATER VALVE WATER METER SPOT ELEVATION TRAFFIC FLOW ARROWS SIGN HANDICAP PARKING SPACE EXISTING CONCRETE PROPOSED CONCRETE PROPOSED TURFSTONE 4" ASTM F405 GRAVITY DRAINLINE om u11111 Q Z 1S U P=- lkf O Z z O Q co o N N I- 0) 0 Q t0 ad 6 Y 7 O o 0 w Z Z Y U- 3 w L11 SCALE: 1" = 30' C201 N/F / CAW E GRAY D6 UA P& 514 0640 f7 12 6276 / PLANT 8 TREES FOR BUFFERING _ S / 7ISTRJb Tiffs PLANT® FOR N/P ca F AJITR o AT Te _ cr 6M RAW A. KAY P61 544 / D6 746 P6 S44 0640 17 22 9A84 S86'13'09"E 656.75' / / / 1ME5 GHAPAS / / / - -4_54 - - - OPERTA pp _ - / / �29 SEPTIG REPAIR ���- - - LP _ bkl nn pe12 151 / 31 c ? i / . s.¢a. 1760 SF A "�--ss IX NC ���rrIVE SEPFIG AREA�571 � SI Sy , y 71 N0 1. OWNER/DEVELOPER: I.G. HOLDINGS, LLC. P.O. BOX 120 IN FEET KITTY HAWK, NC 27949 ( ) PHONE: 252-480-0009 1 inch = 30 ft. 2. THE OWNER INTENDS TO CONSTRUCT A 4 BEDROOM SINGLE FAMILY RESIDENCE AND SEPTIC SYSTEM ON THE EXISTING SITE. NO OTHER CONSTRUCTION SHALL OCCUR AS PART OF THIS PLAN. 3. THE PROPERTY IS RECORDED IN DEED BOOK 1752, PG. 35. DARE COUNTY PIN# 0640 17 22 0121. PROPERTY ADDRESS: 40494 NC HWY 12, AVON, DARE COUNTY, NC. 4. THE PROPERTY IS ZONED GENERAL COMMERCIAL DISTRICT (C-2) AND THIS WILL BE A CONDITIONAL USE. 5. THE SITE IS LOCATED IN FIRM ZONE AE 8', FIRM MAP NUMBER 3730064000J, EFFECTIVE DATE SEPTEMBER 20, 2006. (SUBJECT TO CHANGE BY FEMA) 6. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE SPECIFIED. ELEVATIONS SHOWN ARE HEREON PER NAVD88. 7. AREAS SHOWN ARE BY COORDINATE METHOD. 8. TOTAL AREA = 125.779 SF (2.88 ACRES) AREA OF CANAL = 5.438 SF (0.12 ACRES) UPLAND AREA = 120,341 SF (2.76 ACRES) 9. PARKING HAS BEEN CALCULATED AS FOLLOWS: 1 SPACES/200 SF GROSS FLOOR AREA FOR EXISTING RETAIL 12,427 SF/ 200 = 62.1 SPACES REQUIRED 1 SPACE/BEDROOM FOR PROPOSED RESIDENCE 4 BEDROOMS PROPOSED = 4 SPACES REQUIRED TOTAL: 67 SPACES REQUIRED; 67 SPACES PROVIDED 10. ALL DISTURBED AREAS SHALL BE STABILIZED WITH A COASTAL VEGETATION MIX. 11. MINIMUM BUILDING SETBACKS: FRONT 15, REAR 20' SIDE 10' AREA TO BE DISTURBED = 8131 SF 12. LOT COVERAGE IS AS FOLLOWS: EXISTING RETAIL BUILDING: 12,427 SF PROPOSED RESIDENCE: 2,273 SF EXISTING PAVEMENT: 26,660 SF EXISTING CONCRETE: 6,970 SF PROPOSED CONCRETE: 45 SF TOTAL COVERAGE: 48,375 SF (40.2%) (UPLAND AREA) COVERAGE ALLOWED: 72,205 SF (60.0%) (UPLAND AREA) 13. TOTAL IMPERVIOUS AREA WITHIN 75' AEC: 0.0 SF (0.0 %) 14. THERE ARE NO ADDITIONAL SITE LIGHT FIXTURES PROPOSED. THE DWELLING WILL HAVE TRADITIONAL PORCH LIGHTS. 15. STORMWATER MANAGEMENT WILL BE TO THE EXISTING INFILTRATION BASIN AND A LEVEL SPREADER. 16. THE OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL BUFFERING. ALL REQUIRED LANDSCAPING AND BUFFER AREAS SHALL BE MAINTAINED IN GOOD CONDITION SO AS TO PRESENT A HEALTHY AND ORDERLY APPEARANCE AND SHALL BE KEPT FREE FROM REFUSE AND DEBRIS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE REPLACEMENT OF PLANTS DAMAGED BY INSECTS, DISEASE, VEHICULAR TRAFFIC, AND VANDALISM. 17. ALL NEW UTILITIES ARE TO BE PLACED UNDERGROUND. 18. NO SIGNS FOR THIS USE WILL BE ERECTED. 19. THERE ARE NO DELINEATED WETLANDS ON THIS SITE. 20. THE BUILDING WILL COMPLY WITH VOL. 1C OF THE N.C. STATE BUILDING CODE AND CURRENT NFPA REQUIREMENTS. 21.THE PROPOSED DWELLING WILL BE A 1 OR 2 STORY DWELLING, ELEVATED ON WOOD PILINGS APPROXIMATELY 3.5'-4' FROM THE EXISTING GRADE AND SHALL NOT EXCEED THE MAXIMUM ALLOWABLE HEIGHT OF 52'. 22. SEEDING AND EROSION CONTROL SHALL BE ESTABLISHED WITHIN ANY DISTURBED AREAS. _� Avon Rw-- ortn .. curs ry End Crooke, Ct Pounce C TUNA R LN SUNFISH GT benezer ectric Ln leo� Ln c by' GrOY T Ln Iy �. s KIDDY LN r y n Igrone Blvd p O 6 VLONA AVE NE WAY Mc ULLEN Z �jVLONA oft WAY 8z Hermolet JOHNSON h FLAY ' esteAy Ln wW d, o Brinkley Ln S Watson Ln towe Palazzolo o WcArTY MAP NTS III AFPPROVEC S CAROLINA ENVIRONMENTAL 'N! GEM°NTCOMMISSION ON OF IA"r'r R OI JAL'TY st Sn 7071\1 me A C' I S st�� �c _ �,� ho u �� 1 � t ME E v J V J N N W a p 4i �p d N N ''a EAU o. 0 c m m r N o d o< 0.� U N m N £ N o m a)cwi2u�i�E E�mN m o.5 �a .. 0E�"oa av'i E 3 co ti< v a w y 0 c a ,o0=0 x La v-'<cAn L - C ¢ LL �a4¢�.�2 HFo q H G A„(�(r ids .�F�SSri';1�hy9 I Ift V O LLJ Z §� go (L J w VJ LLJ O CL i 7 LECAM z O Q @Rw R/W CONCRETE MONUMENT 06 IRON PIPE FOUND o IRON ROD FOUND 96 IRON ROD SETOD rT PK NAIL FOUND QeK5 PK NAIL SET a w s rn o n 106W CONCRETE MONUMENT FOUND W © CABLE TV PEDESTAL z z Y b TELEPHONE PEDESTAL �3 3 w LIGHT POLE o U) o o c=i UTILITY POLE SCALE. GUY WIRE 1 " - 3 0' OVERHEAD UTILITY LINE RIGHT OF WAY x x FENCE C201 ° TREELINE/CANOPY - STORM PIPE 7ft-3 CONIC. OR 5 7/8" } LR2�I 1 1/2"� 6x R2" 12" P �- p 1 CONCRETE STAIIDAW C" AM G E NTS N/F / J" CRAY I / CP,A,, E ORAY PP 244 PG 514 OM40 17 12 6276 IV 2" x 4" WHALER 4" x 4" GROUND CONIC. FOOTER mm -I NOTES: 1. ALL FENCE LUMBER TO BE CCA TREATED (APPROVED FOR GROUND CONTACT). 2. ALL FASTNERS, HINGES, LATCHES OR OTHER HARDWARE TO BE HOT DIPPED GALVANIZED. 3. 2" x 4" DIAGONAL BRACING TO BE PROVIDED AT FENCE CORNERS. 'Y DIUM 7 E FENCE DETAIL NTS N A KAY CHAPLAIN PD 746 PG 544 0640 7 22 3454 � S86'13'09"E 656.75' _ 11' N/ff DAMES 641APA5 _ - R06ERTA Ct-WAS - .. I I I - - - _ - - - D6 1080 P6 151 ACTIVE AR 1740 0640 7 12 6113 / / ItSF 3- 115 LF D INLINES 5' O.C. ` I � I V 20 -_ , ---� >_ r ry / EXISTING VEGETATION a �M TO REMAIN ` / ??. I I ¢ I ui \\ �- �y' I It / 7 N/P LLLA MAE PRIDE m 616 P6 48A 0640 17 12 5054 N/F= LUL1 MAE PRICE D6616P&4m 0"0 7 12 59,7 ors N/F /DENNIS WILLIAMS PP, 101-:� Pe 0026 0640 17 II 6P118 1 N07M 1. OWNER/DEVELOPER: I.G. HOLDINGS, LLC. P.O. BOX 120 KITTY HAWK, NC 27949 PHONE: 252-480-0009 2. THE OWNER INTENDS TO CONSTRUCT A 12,427 SF RETAIL BUILDING WITH ONE (1) 1,920 SF ATTACHED 4-BEDROOM APARTMENT. 3. THE PROPERTY IS RECORDED IN DEED BOOK 1451, PG. 295. DARE COUNTY PIN# 0640 17 22 0121. PROPERTY ADDRESS: 40494 NC HWY 12, AVON, DARE COUNTY, NC. 4. THE PROPERTY IS ZONED GENERAL COMMERCIAL DISTRICT (C-2) AND MIXED USES ARE A PERMITTED USE. 5. THE SITE IS LOCATED IN FIRM ZONE AE 8', FIRM MAP NUMBER 3730064000J, EFFECTIVE DATE SEPTEMBER 20, 2006. (SUBJECT TO CHANGE BY FEMA) 6. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE SPECIFIED. ELEVATIONS SHOWN ARE HEREON PER NAVD88. 7. AREAS SHOWN ARE BY COORDINATE METHOD. 8. TOTAL AREA = 125,779 SF (2.88 ACRES) AREA OF CANAL = 5,438 SF (0.12 ACRES) UPLAND AREA = 120,341 SF (2.76 ACRES) 9. PARKING HAS BEEN CALCULATED AS FOLLOWS: 1 SPACES/200 SF GROSS FLOOR AREA 0 12,427 SF = 62.1 SPACES 2.5 SPACES/UNIT 0 1 PROPOSED UNIT = 2.5 SPACES 65 SPACES REQUIRED; 67 SPACES PROVIDED 10. ALL DISTURBED AREAS SHALL BE STABILIZED WITH A COASTAL VEGETATION MIX. 11. MINIMUM BUILDING SETBACKS: FRONT 15' REAR 20' SIDE 10' 12. AREA TO BE DISTURBED - ON -SITE: ±105,499 SF (2.42 ACRES) OFF -SITE: t 5,895 SF (0.14 ACRES) TOTAL AREA DISTURBED: 111,394 SF (2.56 ACRES) 13. LOT COVERAGE IS AS FOLLOWS: PROPOSED BUILDING: 12,427 SF PROPOSED PAVEMENT: 26,660 SF PROPOSED CONCRETE: 6,297 SF PROPOSED COVERAGE: 45,384 SF (37.7%) (UPLAND AREA) COVERAGE ALLOWED: 72,205 SF (60.0%) (UPLAND AREA) TOTAL IMPERVIOUS AREA WITHIN 75' AEC: 0.0 SF (0.0 %) 14. LIGHTS FOR THIS ADDITION WILL BE 250W HPS TYPE SL. LIGHTING WILL MEET MINIMUM DARE COUNTY STANDARDS. (SEE LIGHTING PLAN) 15. ALL OUTDOOR LIGHTING SHALL BE ERECTED, ALTERED AND MAINTAINED IN ACCORDANCE WITH THE PROVISIONS IN SECTION 22.60 OF THE DARE COUNTY CODE OF ORDINANCES. ALL LIGHT PRODUCED ON SITE SHALL BE CONTAINED WITHIN THE PERIMETER OF THE SITE BY DESIGN, ORIENTATION OR SHIELDING OF THE LIGHT SOURCE. AREA WITH � 14' S86'00'34W 666.15' GRAPHIC SCALE 30 0 15 30 60 120 I PNJN/' CMOGO LLG N/F I D6 140a P& Im ANN 6E6r HAM 9649 17 21 2919 pp 2-12 117 064017 11P 65095 (IN FEET) 1 INCH = 30 FT. 16. STORMWATER MANAGEMENT WILL BE A HIGH -DENSITY PROJECT UTILIZING CONVEYANCE TO AN INFILTRATION BASIN AND A LEVEL SPREADER. ALL SURFACE RUNOFF WILL UTILIZE SHEETFLOW TO BE COLLECTED BY DRAINAGE STRUCTURES AND CONVEYED VIA PIPES AND CURBS TO AN INFILTRATION BASIN TOWARDS THE REAR OF THE SITE. ALL RUNOFF FROM THE STRUCTURE WILL BE DIRECTED VIA RAIN GUTTERS INTO THE DRAINAGE PIPE ON THE SOUTH SIDE OF THE BUILDING TO BE CONVEYED TO THE INFILTRATION BASIN. A BYPASS DEVICE PRECEDES THE INFILTRATION BASIN AND WILL DISPERSE THE RUNOFF EXCEEDING A 1-1/2 INCH STORM EVENT THROUGH A VEGETATED FILTER USING A LEVEL SPREADER. THE LEVEL SPREADER WILL BE LOCATED APPROXIMATELY 78' FROM THE EDGE OF THE CANAL. THE SITE WILL BE GRADED TO PREVENT RUNOFF INTO THE ADJACENT PROPERTIES. 17. THE OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL BUFFERING. ALL REQUIRED LANDSCAPING AND BUFFER AREAS SHALL BE MAINTAINED IN GOOD CONDITION SO AS TO PRESENT A HEALTHY AND ORDERLY APPEARANCE AND SHALL BE KEPT FREE FROM REFUSE AND DEBRIS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE REPLACEMENT OF PLANTS DAMAGED BY INSECTS, DISEASE, VEHICULAR TRAFFIC, AND VANDALISM. 18. SILT FENCE TO BE INSTALLED ON SITE AS SHOWN ON EROSION CONTROL/GRADING PLAN. 19. ALL NEW UTILITIES ARE TO BE PLACED UNDERGROUND. 20. ALL SIGNS SHALL BE ERECTED, ALTERED AND MAINTAINED IN ACCORDANCE WITH THE PROVISIONS IN CHAPTER 158 OF THE DARE COUNTY CODE OF ORDINANCES. 21. THERE ARE NO DELINEATED WETLANDS ON THIS SITE. 22. THE BUILDING WILL COMPLY WITH VOL. 1C OF THE N.C. STATE BUILDING CODE AND CURRENT NFPA REQUIREMENTS. 23. BUILDING HEIGHT SHALL NOT EXCEED 52' 24. SEEDING AND EROSION CONTROL SHALL BE ESTABLISHED WITHIN ANY DISTURBED RIGHT-OF-WAY AREAS. NC 12 RIGHT-OF-WAY SHALL BE RESTORED AFTER CONSTRUCTION WITH GRADING AND STABILIZATION OF ALL DISTURBED AREAS. EXISTING CULVERTS SHALL BE REMOVED AND/OR REPLACED IF DAMAGED DURING CONSTRUCTION. VAN ACCESSIBLE 01 PARK PARKING THIS DRAWING ORIGINALLY 'o ISSUED AND SEALED ® I John M. DeLucia, 1675959, ON October 31, 2007. THIS MEDIUM SHALL NOT BE MAXIMUM CONSIDERED A CERTIFIED PENALTY m DOCUMENT. $250 N z 1'-0"x1'-6"x.08O" ALUMINUM 0 - HANDICAP PARKING SIGN. SIGN 0 TO READ "RESERVED PARKING" 0 mm WITH IDENTIFICATION SYMBOL, 0 00 BOLTED TO STEEL TUBE WITH 1 3/8" CADMIUM PLATED BOLTS, 't LO NUTS AND WASHERS. 00 w _0 CORNER RADIUS: - z 1-1/2" (TYPICAL) 0 W F- 0 z 0 U 4"x4" STYP POST I _ io 0 �5 m om oz 0- NOTE: w 9 1. REGARDLESS OF AGE, ALL ACCESSIBLE SPACES SHALL BE IDENTIFIED BY ABOVEGROUND SIGNS ONLY am (SEE N.C.G.S.). 2. NEW SPACES SHALL NOT USE GROUND -PAINTED r,r, SYMBOLS. ? 000 3. ACCESSIBLE SPACES ARE REQUIRED TO BE STRIPED OFF ONLY; BLUE COLORING IS NOT NECESSARY NOT m REQUIRED. �\ 4. STRIPING IS WHITE ON DARK PAVEMENT; BLACK ON M LIGHT PAVEMENT. (N.C.D.O.T.). �a 5. CONDITION (A)PEDESTRIAN PATH DOES NOT PASS UNDER OR AROUND SIGN. CONDITION (B) PEDESTRIAN PATH GOES BY, UNDER, OR AROUND SIGN. 6. STANDARD SIGN COLORS: BACKGROUND - WHITE, LETTERING/BORDER - GREEN, FIGURE - WHITE ON BLUE FIELD. HAAMAPP® PAFPMG SDI DEr/iL NTS 87E ro PROPOSED RETAINING WALL Avon 00RO�N Price orth BOs ry Gu CC FINISHED GRADE End $ Croaker Ct AREA TO BE FILLED �q / // / //j/\//\�/\\ • C GRAY TUNA R LN Pounce SUNFlSN GT be zer ectric Ln p N ea/ s GrOY bby EXISTING GRADE L.n LLA• rye LN igrone Blvd KIDDY MCMULLEN A DR VLONA AVE UNE WAY 3/GONA RE WAY Q) T Hermolet OG �/ O 3GNNSON y FLAY L-n ••� TIE BACK AS ,'y J estarlY REQUIRED �6P o\a 30 M ;i M2V!V`Ag7 AIP LE0190 - - PROPOSED SWALE/STORMWATER BASIN G�,A, R/W CONCRETE MONUMENT MINIMUM BUILDING LINE OFr IRON PIPE FOUND • • • • • • • • • • . AEC 75' LINE IRON ROD FOUND AEC 30' LINE (IR 5 IRON ROD SET PK NAIL FOUND ,....,.,,..,...................r.�,.,�..,f.....,. EXISTING TREELINE/CANOPY Q5 PK NAIL SET .ter. NEW TREELINE o CONCRETE MONUMENT FOUND * LIGHTPOLE /LIGHTING © CABLE TV PEDESTAL (D TELEPHONE PEDESTAL ® NEW DROP INLET tea, UTILITY POLE • NEW JUNCTION BOX { EXISTING GUY WIRE NEW DRAINAGE PIPE Wes- OVERHEAD UTILITY LINE 10 RIP RAP - - - -- RIGHT OF WAY - - EXISTING DITCH/SHORELINE SANITARY MANHOLE -x x EXISTING FENCE H SANITARY VALVE ---- ,>-- --- EXISTING CONTOUR _FM NEW FORCEMAIN 10- NEW CONTOUR 550 EXISTING SPOT ELEVATION I .�I 404 WETLANDS 8.50 NEW SPOT ELEVATION EXISTING CONCRETE w EXISTING WATERLINE EXISTING GRAVEL rt EXISTING FIRE HYDRANT ca EXISTING WATER VALVE EXISTING PAVEMENT EXISTING WATER METER NEW CONCRETE PAVEMENT yy NEW E _%/.:;`. D NEW CONCRETE � NEW FIRE HYDRANT FIRHYDRANT N NEW WATER VALVE SIGHT DISTANCE TRIANGLE • NEW WATER METER 4) TRAFFIC FLOW ARROWS SF SILT FENCE AREA OF DISTURBANCE/ �QQ SIGN PROJECT LIMITS HANDICAP PARKING SPACE M ROCK CHECK DAM STORMWATER FLOW ARROW 0 N 0 Q O QJ C, w f Q 7 � In � r w 0 w Z Z Y w c2 w 0 N In o U C SCALE: 1 " = 30' SHEET: 1 OF 4 N/F / JOIN GRAY 6RAUE GRAY / D6 244 P5 514 0640 17 12 6276 , N/F JA1v1ES 01APA5 ROPERTA GMAPAS Db Iaao Pa 151 0640 17 12 6113 N/F LU1A MAE PRICE D6 616 Pe 464 0"0 17 12 5054 N/F LLLA MAE PRIDE D6 616 P& 402 0640 17 12 5537 rFIE] 2 N/F / DENNIS WILLI" ^O ' N/ff Db 1013 P6 0016 -% ANN PECK -NAM ObkO 7 II 68Z51 •..;�t..� �' D6 222 P& 117 0640 17 II saga SE�D�I�MpE�NTA�T,ION EROSION CONTROL NOTES L NARRATIVES THIS PROJECT CONSISTS OF THE DEVELOPMENT OF 2.88 ACRES OF LAND IN AVON, NORTH CAROLINA. THE DEVELOPER INTENDS TO CONSTRUCT A 12,427 SF RETAIL BUILDING WITH ONE (1) 1,920 SF 4-BEDROOM APARTMENT. THE PARCEL IS ADJOINED ON THE WEST SIDE BY MILL CREEK CANAL. THE SITE IS RELATIVELY LEVEL AND PARTIALLY WOODED. APPROXIMATELY 105,499 SF (2.42 ACRES) ON -SITE AND 5,895 SF (0.14 ACRES) OFF -SITE ARE TO BE DISTURBED. ALL INFRASTRUCTURE CONSTRUCTION IS SCHEDULED TO BEGIN IN DECEMBER 2007 AND BE COMPLETED WITHIN THREE MONTHS. THE SITE IS ACCESSED BY AN EXISTING GRAVEL DRIVEWAY, WHICH WILL BE IMPROVED TO MEET CONSTRUCTION ENTRANCE STANDARDS. SILT FENCES ARE PROPOSED TO CONTAIN ANY MOVEMENT OF SOIL DURING CONSTRUCTION. THIS PLAN ILLUSTRATES SILT FENCES LOCATION. SHOULD THE NEED FOR ADDITIONAL FENCING BE DETERMINED DURING CONSTRUCTION, IT WILL BE INSTALLED AS DIRECTED BY THE ENGINEER OR NC DEHNR AGENT. A. SOILS: SOIL TYPES AS MAPPED IN THE SOIL SURVEY OF DARE COUNTY: DUCKSTON FINE SAND (DtA) COROLLA-DUCKSTON COMPLEX (CrB) 11. CONSTRUCTION SEQUENCE - OBTAIN PLAN APPROVAL. FLAG OR STAKE WORK LIMITS. CONTACT ULOCO FOR LOCATION OF UNDERGROUND UTILITIES. HOLD PRE -CONSTRUCTION MEETING. INSTALL SILT FENCING. COORDINATE WITH ENGINEER TO ESTABLISH ANY AREA OF SELECTIVE CLEARING. CLEAR LOT OF EXISTING VEGETATION AS SHOWN. SEED, FERTILIZE AND WATER DISTURBED AREAS TO STABILIZE. IMPROVE GRAVEL CONSTRUCTION ENTRANCE AND SILT FENCING. PLACE, COMPACT AND TEST ALL FILL MATERIAL PURSUANT TO GRADING PLAN. INSTALL AND TEST ALL PROPOSED UNDERGROUND UTILITIES. STABILIZE DISTURBED AREAS WITH TEMPORARY VEGETATION. COMMENCE CONSTRUCTION OF IMPROVEMENTS. SEED, FERTILIZE AND WATER DISTURBED AREA TO STABILIZE AS NOTED IN SECTION IV. REMOVE SILT FENCES ONCE PERMANENT VEGETATION IS ESTABLISHED. N. SEDIMENTATION AND EROSION CONTROL NOTES 1. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL CONTACT ULOCO (800-632-4949) TO LOCATE UNDERGROUND UTILITIES. 2. ALL CONSTRUCTION TRAFFIC SHALL UTILIZE THE CONSTRUCTION ENTRANCE AS DESIGNATED ON THE PLAN. 3. ALL REMOVAL AND DISPOSAL OF SITE DEBRIS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REMOVED BY THE CONTRACTOR TO AN OFF -SITE LOCATION. 4. AREAS WHICH HAVE BEEN DESIGNATED IN THE PLANS TO REMAIN UNDISTURBED SHALL BE IDENTIFIED PRIOR TO CLEARING. IN ADDITION TO SECTIONS SHOWN WHERE ALL VEGETATION IS TO REMAIN, ADDITIONAL SPECIMEN TREES MAY BE SPECIFIED AND FLAGGED TO REMAIN. 5. NO BURNING IS PERMITTED ON SITE. 6. NO BORROW PERMITTED FROM THE SITE EXCEPT AS NECESSARY FOR GRADING OPERATIONS. 7. EVERYTHING WITHIN "PROJECT LIMITS" ESTABLISHED BY ACTUAL ADJACENT PROPERTY LINES SHALL BE CLEARED UNLESS NOTED TO REMAIN. CONTACT THE ARCHITECT IF UNCLEAR. 8. STORMWATER RUNOFF DRAINS TO MILL CREEK CANAL WHICH IS CLASSIFIED AS SA WATERS AND IS IN THE PASQUOTANK RIVER BASIN. 9. EXISTING TOPOGRAPHY INFORMATION BASED ON THE SURVEY INFORMATION OBTAINED BY ALBEMARLE AND ASSOCIATES, LTD. ON SEPTEMBER 25, 2007. Ali r; N/F A. KAY C41APLAIN D6 746 Pe 544 0640 17 22 3484 GAVLDW MOTES 1. ALL CONSTRUCTION TRAFFIC SHALL UTILIZE THE CONSTRUCTION ENTRANCE AS DESIGNATED. 2. PRIOR TO COMMENCEMENT OF ANY LAND DISTURBING ACTIVITIES, ALL EROSION AND SEDIMENTATION CONTROL MEASURES IDENTIFIED ON THIS PLAN SHALL BE INSTALLED IN ACCORDANCE WITH THIS PLAN AND NCDENR REGULATIONS. 3. THE CONTRACTOR SHALL ENSURE THAT AREAS OUTSIDE OF THE LIMITS OF LAND DISTURBING AS WELL AS TREES SPECIFICALLY NOTED FOR PROTECTION ARE NOT ADVERSELY IMPACTED BY ANY CLEARING ACTIVITIES. 4. PROVIDE A GROUNDCOVER (TEMPORARY OR PERMANENT) ON EXPOSED SLOPES WITHING 21 CALENDAR DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING; AND A PERMANENT GROUNDCOVER FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 5. IF ADDITIONAL MEASURES TO RESTRAIN EROSION BY WIND OR WATER ARE REQUIRED, MEASURES SHALL BE INSTALLED AS DIRECTED BY THE ENGINEER OR DARE COUNTY. 6. SOIL EROSION AND SEDIMENTATION CONTROLS TO BE INSPECTED, MAINTAINED AND REPAIRED AS NECESSARY BY THE CONTRACTOR. 7. LIMITS OF SLOPES AND GRADING SHALL BE IN ACCORDANCE WITH THE LIMITS SHOWN HEREON. 8. AREAS WHICH ARE TO BE FILLED SHALL BE RAISED IN COMPACTED SEQUENTIAL LIFTS NOT TO EXCEED 8 INCHES IN DEPTH. FILL MATERIAL SHALL BE CLEAN GROUP 1 SANDY FILL AND SHALL BE VERIFIED BY THE ENGINEER. DR4MMaE NOTES: 1. ALL STORM SEWERS SHALL BE PLACED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 2. DROP INLETS SHALL BE CONSTRUCTED PER NCDOT 840. 3. ALL OPEN PIPE ENDS SHALL BE FITTED WITH A FLARED END SECTION OF THE SAME MATERIAL AND SIZE. END SECTIONS AND FLUMES SHALL BE PROVIDED WITH TEN CUBIC FEET OF CLASS "B" RIP -RAP, PLACED TWELVE INCHES IN DEPTH. 4. INSTALLATION OF STORMWATER MANAGEMENT MEASURES SHALL BE IN ACCORDANCE WITH THIS PLAN AND REQUIREMENTS STIPULATED BY THE DIVISION OF WATER QUALITY STORMWATER PERMIT. 5. RUNOFF FROM CONSTRUCTION ACTIVITIES IS TO BE DIRECTED TO THE STORMWATER BASIN, THE ENTIRE BASIN BOTTOM SHALL BE TILLED/DISCED TO RESTORE INFILTRATION ABILITIES. 6. ALL DRAINAGE STRUCTURES TO BE BUILT IN PLACE IN ACCORDANCE WITH NCDOT 840.15 & 840.01, WITF THE EXCEPTION OF THE STRUCTURE SHOWN IN THE BYPASS. STOMWAT@? MANAQEAeff M0118V,4NCE NOTES 1. UPON ACCEPTANCE BY THE OWNER, IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE NECESSARY MAINTENANCE SO THAT THE STORMWATER SYSTEM WILL FUNCTION AS INTENDED. 2. AFTER EVERY RUNOFF PRODUCING RAINFALL EVENT AND AT LEAST MONTHLY, INSPECT THE INFILTRATION SYSTEM FOR EROSION, TRASH ACCUMULATION, VEGETATIVE COVER, AND GENERAL CONDITION. ALSO INSPECT THE INFLOW STRUCTURES, CURB & GUTTERS, FLUMES, RIP -RAP, AND BASIN FOR OBSTRUCTION OR DETERIORATION. REMOVE ANY BLOCKAGE AND REPAIR THE STRUCTURE TO APPROVED DESIGN SPECIFICATIONS 3. REPAIR ERODED AREAS IMMEDIATELY, RE -SEED AS NECESSARY TO MAINTAIN ADEQUATE VEGETATIVE COVER, MOW VEGETATED COVER TO MAINTAIN A MAXIMUM HEIGHT OF SIX INCHES, AND REMOVE TRASH AS NEEDED. SOD SHALL NOT BE PLACED ALONG THE BOTTOM OF INFILTRATION BASINS. 4. CHECK FOR SEDIMENTATION WITHIN THE BASIN ANNUALLY. IF DEPOSITION OF MATERIAL IS OBSERVED WITHIN THE SYSTEM, REESTABLISH DESIGN GRADES AS INDICATED ON APPROVED SITE PLAN.INSPECT BASIN WALLS AND STRUCTURES TO ENSURE THAT THEY ARE MAINTAINED AT THEIR DESIGN ELEVATIONS. IF EROSION OCCURS, REESTABLISH DESIGN ELEVATIONS AS INDICATED ON APPROVED SITE PLAN. 5. REFER TO INFILTRATION BASIN OPERATION AND MAINTENANCE AGREEMENT FOR REQUIRED MAINTENANCE OF THE INFILTRATION BASIN. IGIRAPHIC SCALE (IN FEET) 1 INCH = 30 FT. an POST SPACING SHALL BE clicsW 6' MAX. WITHOUT I- g O \ REINFORCING WIRE, MAY Q BE INCREASED TO 8' WITH REINFORCING WIRE. i..�0 Cn Ln 9.w / COMPACTED FILL STEEL SUPPORT POST SYNTHETIC FIBRE JUTE MESH FILTER FABRIC EXTENSIOn INTO THENOF TRENCHTER FABRIC WIRE 47 SLT FENCE DETAL NTS NO 1. WASHED STONE (#4 STONE OR 2" TO 3" AGGREGATE). PAD TO BE 501 X 20'W X 6"D AT A MINIMUM. 2. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS IS TO BE PROVIDED. 3. ENTRANCE(S) SHOULD BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. 4. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOP DRESSING WITH STONE SHALL BE NECESSARY. NOTE: NTS APPLICABLE AT ALL POINTS OF INGRESS & EGRESS UNTIL SITE IS STABILIZED, FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE MUST BE PROVIDED. PROPOSED R BUILDING DITCH NC HWY 12 FFE = 8. 1' A EXISTING TOP OF BANK 12" HDPE PROPOSED INV 3.26' 2 RET. WALL 12" NCDOT #57 TOP EL = 5.0' EX. 15" RCP INV 0.88' ON FORESLOPE 5' TO BE REMOVED NOTES: (; T I FLOW 1 r 11 1. CHECK DAMS SHALL BE INSPECTED NTS MONTHLY AND AFTER ALL SIGNIFICANT RAINFALL EVENTS. EXISTING NCDOT CLASS 'B' 2. ONCE THE UPSTREAM PORTIONS OF 6' 10' 6' DITCH INVERT RIP RAP THE DITCH HAVE BEEN FILLED, 3. ROCK SHALL BE REMOVED AND A STOCKPILED ON SITE FOR USE A TO PARK. l NEEDED BY THE OWNER. TO MILL 4 TOP EL=4.5 EL=4.1 p �+L � DAM DErAL REEK CANAL 1 NTS a1 BOTTOM EL=3.0 SPECIES RATE K-31 FESCUE 3 LB/1000 SF COMMON BERMUDAGRASS 1 LB/1000 SF WINTER RYE GRAIN 3 LB/1000 SF MAY 16 - JILY 16 PEFLW@R SEEDM SPECIES RATE K-31 FESCUE 3 LB/1000 SF COMMON BERMUDAGRASS 1 LB/1000 SF GERMAN MILLET 3 LB/1000 SF AUC LIUr 15 - APRL I TEMPORARY SEEDD10 SPECIES RATE K-31 FESCUE 3 LB/1000 SF WINTER RYE GRAIN 5 LB/1000 SF APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 500 LB PER ACRE OF 10-10-10 FERTILIZER. MULCH USE JUTE, EXCELSIOR MATTING OR OTHER EFFECTIVE CHANNEL LINING MATERIAL TO COVER BOTTOM AND SIDES OF SWALES. ANCHOR MATTING PER MANUFACTURERS RECOMMENDATIONS. HYDROSEEDING IS ALSO AN ACCEPTABLE METHOD OF TEMPORARY STABILIZATION MANTENANCE A MINIMUM OF 3 WEEKS IS REQUIRED TO FOR ESTABLISHMENT. INSPECT AND REPAIR MULCH FREQUENTLY. FERTILIZE THE FOLLOWING SPRING WITH 50 LB/ ACRE NITROGEN. - 50 LF 8" PERFORATED VARIES HDPE IN RIVER ROCK BED STOM MAM? BAaN DETAL BENCHMARK NTS TOP OF LID MANHOLE EL 5.0' EL. 5.0' 6" CURB AROUND MANHOLE EL 5.0' 6" CURB AROUND TOP AT EL 4.5' 6" CURB AROUND TOP AT EL 4.5' s TOP AT EL 4.5' Y d ° m INLET EL 4.0' TO BASIN - d ." .. X X VARIES d / 1" WEEP HOLES SECTION X-X 15 H E d 15 HDPE 15" HOPE _ d CONCRETE COVER & MANHOLE ACCESS 6" EL 5.0' TO BYPASS q EAWMOIX DROP I1LJE-7 NTS NI u� m N N rn �2 od¢� U N U 2 9 N d yNj V ¢ N N N �N `m''7o.>._.mn 0 o E oa E 0 v N, '° v n¢ 5 2 n m O r c Q v m a ¢�aYaLL Pof�N u ri 20 u T z O Y PLAN o04 M d C.`UrtEL DROP 11L&7 AND MANHOLE NOTES` o o 1. MORTAR JOINTS 1/2" t 1/8" THICK. 2. USE CLASS "B" CONCRETE THROUGHOUT. w w 3. USE FORMS FOR CONSTRUCTION OF BOTTOM SLAB. z z y 4. USE BRICK OR CONCRETE BLOCK WHICH COMPLIES WTIH L i c 3 w THE REQUIREMENTS OF SECTION 840 OF THE STANDARD Qo ND Li o o m SPECIFICATIONS. 5. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB SCALE' OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00 6. INSTALL (2) 1" WEEP HOLES AS DIRECTED BY THE )1 O 1 ENGINEER. 7. FOR 8'-0" IN HEIGHT OF LESS, USE 8" WALL. 8. CONSTRUCT WITH PIPE THROATS MATCHING. 9. USE TYPE "E", "F" AND "G" GRATES UNLESS OTHERWISE SHEET: INDICATED. 10. CHAMFER ALL EXPOSED CORNERS 1". 2 OF 4