HomeMy WebLinkAboutWQ0043016_Application (FTSE)_20211203 (2)DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 DESIGN CALCULATIONS FOR THE WATSON RENTALS, LLC. DUPLEX GRINDER PUMP STATION CONNECT TO: TUCKASEIGEE WATER & SEWER AUTHORITY JACKSON COUNTY, NORTH CAROLINA NOVEMBER 2021 Yy51511111I+ r �i ' C d R/ +J ! f : oa4621a o'yuSiyned by: 0 '� �. JrrI �l1111 1 - Prepared By - VAUGHN & MELTON CONSULTING ENGINEERS 2 Worth Circle, Suite 1 Johnson City, TN 37601 Telephone: (423) 467-8401 www.vaughnmelton.com V&M Project No. 032150-15 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 DESIGN CALCULATIONS WATSON RENTALS, LLC. SANITARY SEWAGE DUPLEX GRINDER STATION AND FORCE MAIN GENERAL: Watson Rentals LLC. has formally requested sanitary sewer service from the Tuckaseigee Water & Sewer Authority (TWSA). TWSA will allow this connection based on required permitting from NCDEQ- Water Resources. This project includes a new duplex grinder pump station, new 2-inch low-pressure forcemain, private 6-inch gravity sewer service, abandonment of two septic tanks, and connection to an existing 6-inch PVC TWSA forcemain. Vaughn and Melton (V&M) was hired to provide the design of the sewer improvements. The proposed plan calls for installing one 3.5 foot diameter x 8-feet deep duplex fiberglass grinder pump basin, approximately 225 linear feet of new 6" gravity line, approximately 300 linear feet of new 2-inch low-pressure forcemain, a pump control panel w/ portable generator hook-up, along with erosion and sediment control. The proposed project will initially serve 11- apartment units with an estimated flow of 240 gpd per apartment for a total of 2,640 gallons per day. The design also includes future development plans for up to an additional 20- units or additional 4,800 gpd contribution. A new 6-inch gravity line will be installed to serve the 31 apartments. The gravity line will tie to the duplex grinder pump station as shown on the plans. The new 2" force main will discharge into an existing 6-inch forcemain located on Hamsfeld Hall Road that serves LS #6 on Savannah Creek. The approximate length of 6" to be utilized by the new pumps is 1700 LF. The existing 6" force sewer line conveys wastewater to TWSA Plant No. 1. LS NO. 6 is a duplex pump station with pumps rated at approximately 290 gpm at 70 TDH, 20 HP, each. Refer to Table 1 in Appendix A for the existing lift station hydraulics. All work will be completed per the requirements of NCDEQ and the Tuckaseigee Water & Sewer Authority. Per the findings of this report, the existing force main and WWTP has enough reserve capacity to accept the new flow from the new duplex grinder pump station. PROJECTED FLOW: The projected flow to this sewer pump station will be established as follows: DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 1 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 A. Flow Contribution: Historical water usage for the property with the rentals is approximately 7,000 gallons per month. The projected instantaneous flow was calculated based on design criteria from 15A NCAC 02T.0114 Wastewater Design Flow Rates and based on projected number of dwelling units & bedrooms per Table 1 in Appendix A. Existing & future flow is estimated = 31 units x 240 gpd/unit = 7,440 GPD. The average instantaneous flow based on a 16hr-Q was calculated to be = 7.8 GPM. Refer to Table 2 in Appendix A. A peak flow factor of 3.5 will be used to size the new pumps. Thus, the peak flow projected will be: 3.5 x 7.8 GPM = 27.13 GPM Therefore, use: Design Instantaneous Influent Flow = 7.8 GPM Pump Design Flow = 27.13 GPM B. Wet -Well Design: New duplex submersible type grinder pumps will be utilized. New wet -well dimensions = 3.5' inside diameter Invert of incoming sewer line = 2023.8' Finished grade elevation = 2026.3' Top of wet -well elevation = 2026.8' Wet -well Invert elevation = 2018.8' 100-year base flood elevation = 2021.1 established (refer to Firm Map attached in the Appendix E). Assume 2.0' of water submergence for cooling is required by the grinder pump manufacturer (otherwise a water-cooling jacket will be utilized on each pump). Calculations to determine the wet -well volume are as follows: Useable Sump Volume = 15 x Q eq. 19.2, Reference 1 Chr DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 2 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Where Q = Qdesign = 27.13 GPM Chr= Pump cycles per hour, assume 6 Sump volume = 15 x 27.13 GPM = 70 Gallons 6 Cycles Since the pump station's wet -well diameter will be 3.5 feet, the storage per foot is as follows: Storage Volume = Volume of Pump Station = 3.14/4 x 3.5' x 3.5' x 1 Ft depth = 9.61 Ft3 = 9.61 Ft3 x 7.48 gal/Ft3 = 72 gallons / foot depth Therefore, sump depth required = useable sump volume = 70 gallons = 1 ft. storage volume 72 gallons/ft. Use 1 ft pump down will be utilized. Refer to Figure 1 and the pump cycle calculations Table No.3, attached in Appendix C. C. Emergency Operation: A portable generator set and a manual transfer switch will be provided to support the needs of the pump station in case of a power outage. The portable generator will include a fuel storage tank with a fuel capacity capable of operating the station for 6 hrs at full load. D. Force Main Size Selection: Select pipe diameter to provide a force main scouring velocity of at least 2.0 ft/sec., at minimum flow: V = Q where Q = minimum flow, A = area of pipe A Assume minimum pump flow will be pre-set at 27.13 GPM. A = Q = 27.13 GPM x 1 Ft3/sec/449 = 0.031 Ft2 V 2.0 Ft/sec. DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 3 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 A = Hd2 = 0.031 Ft2 4 where d = pipe diameter d=0.198'or2.3" Use 2" force main Therefore, based on the pump design flow of 28 GPM, the pipe velocity in the 2" pipe will be approximately 2.86 fps. Pump Selection: Two (2) new submersible grinder pumps of equal capacity will be utilized. Automatic alternation will be provided. One pump will serve as standby. The attached spreadsheet calculations (Refer to Table 4 in Appendix B) were utilized to establish the system's operating curve: DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 4 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Based on the referenced hydraulic calculations, the proposed pump will need to have a design point of 28 GPM at 38 TDH. The pump specified will be a 2 HP explosion proof submersible grinder pump, 230- volt, 3450 rpm, single-phase, Hydromatic HPGX200, with 4.25" diameter impeller, or equal. Refer to the pump curve and other information attached in Appendix D. E. System Operation: The duplex grinder pump station will receive sanitary sewage from the single family apartments as noted previously. Flow will be collected in the wet -well station before it gets pumped into the collection system via the new 2" force main. The operating pump flow will range between 32 GPM (one pump running) to approximately 44 GPM (when two pumps are operating). When LS NO. 6 is ON at the same time, the projected flow from this station will be approximately 27 gpm due to the additional headloss in the 6" force main. F. Odor Control Calculations: Odor control is recommended if detention in wet -well or force main exceeds 30 minutes. 1) Check wet -well detention time based on average incoming flow (7.8 GPM) = 72 gal/Ft x 1' = 10 minutes < 30 minutes, therefore Okay. 7.8 GPM 2) Check force main detention time based on minimum pump flow: = 299' x II (2/12)2/4 x 7.48 = 1.80 minutes <_ 30 minutes 27.13 GPM Therefore, odor control is not required. Buoyancy Calculations: Design Note: Mechanical equipment, water weight, and other temporary loads inside the wet -well shall not be included in the calculations. DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 5 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 G. Buoyancy Force: BF = (displaced volume)(unit wt. water) For design purposes, assume water table is 1.0 feet below finished grade elevation, at the 100 yr flood elevation of 2021.1'. ROUND COLLAR Grade Elevation 2026.80 Feet Grade Elevation Structure Invert 2018.80 Feet Structure Invert HWL (GW) 2026.80 Feet ASSUMED t 0 inches Structure Wall Thickness b 0 inches Structure Base Thickness D 36 inches Structure Inside Diameter H (structure) H (water) 12 inches 18 inches 8.00 feet 7.00 feet Collar Slab Thickness Collar Slab Overhang Structure Depth Invert of Structure to Ground Water Spw 62.4 pcf Specific Gravity of Water Spcon 150 pcf Specific Gravity of Concrete Sp soil 100 pcf Specific Gravity of Soil F buoy 4,852 Pounds F slab 3,181 Pounds Fwalls - Pounds F soil 6,379 Pounds Fdown 9,560 Pounds SF 1.970 1.5 Required OK Therefore: SAFETY FACTOR = 9,560 / 6,379 = 1.97, therefore okay. DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 6 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Reference List: 1. Water pumps and pumping stations, McGraw-Hill, James B. Risnell, 2002. DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 7 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 APPENDICES DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 8 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 APPENDIX A DESIGN CRITERIA DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 9 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Watson Rentals, LLC Flow Calculations a C7 a N I I 2 O. c7 QI 0 0 0 N 0.1 N 1 H 2 O LO el o 0 (.51 N N N H Z D *k I W N D co co N N r-I 0 r-I N c D to C G) 3 0 Future Single Bedroom Dwelling Unit 0- 0 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Project: Existing PS No. 6 Savannah Creek Job Number: 32150-15 Date: 11/8/2021 Jackson County NC Wet -well and yard piping Maximum Flow Rate: Minimum Water level in wet -well: Finish Grade @ P.S. site: Elevation @ highest point in the system: Static Head: Pipe length inside wet -well: Pipe size inside wet -well: Pumping Distance (equiv. yard piping length): Type of Yard Pipe: C Factor Used: Diameter of Pipe (yard piping): Table 1 290 GPM 2015 feet 2027 feet 2063 feet 48 feet 15 feet 4 inches 3529 feet (79+3450) DIP and PVC 120+140 Using Hazen -Williams Equation: h = 10.44(length){(flow^1.85)/[(C^1.85)(diameter)^4.8655)} Note: C = 140 for existing PVC 6 inches FLOW (GPM) FRICTION LOSS F & S HEAD 0 0.000 48.000 20 0.166 48.166 40 0.598 48.598 60 1.267 49.267 80 2.157 50.157 100 3.259 51.259 120 4.567 52.567 140 6.074 54.074 160 7.776 55.776 180 9.669 57.669 200 11.750 59.750 220 14.015 62.015 240 16.463 64.463 260 19.091 67.091 280 21.896 69.896 300 24.877 72.877 320 28.031 76.031 340 31.358 79.358 360 34.856 82.856 380 38.523 86.523 400 42.357 90.357 Design Point 290 gpm @ 70 TDH DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Project: Existing PS No. 6 Savannah Creek Job Number: 32150-15 Date: 11/8/2021 Jackson County NC Yard piping only- Existing Force Main Maximum Flow Rate: Elevation at exit point of valve box Elevation @ highest point in the system: Static Head: Pumping Distance (equi. yard piping length): Type of Pipe: C Factor Used: Diameter of Pipe (yard piping): Using Hazen -Williams Equation: h = 10.44(length){(flow^1.85)/[(C^1.85)(diameter)"4.8655)) Note: C = 140 for existing PVC FLOW (GPM) 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 VELOCITY: V=Q/A OPERATING FLOW (Q) IN GPM = 290 OPERATING FLOW (Q) IN CFS = 0.646 AREA (A) = 0.196 SO, VELOCITY (V) IN FPS = 3.291 290 GPM 2025 feet 2062 feet 37 feet 3450 feet PVC 140 6 inches FRICTION LOSS 0.000 0.161 0.581 1.229 2.093 3.163 4.432 5.894 7.546 9.383 11.402 13.601 15.976 18.526 21.249 24.141 27.203 30.432 33.826 37.384 41.105 Table 1-Cont. DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Project: Job Number: Date: Wet -well piping only Maximum Flow Rate: Minimum water level in wet -well: Exit Elevation of wet -well Static Head: Pipe length inside wet -well: Pipe size inside wet -well: Type of Pipe: C Factor Used: Number Fitting 3 90° Elbow 1 plug Valve 1 Check valve 1 Tee Existing PS No. 6 Savannah Creek 32150-15 11/8/2021 Jackson County NC Size (in) Eq. Length (ft) 6 7 6 3 6 30 6 15 Minor Losses: Total Length (including minor losses): 290 GPM 2015 feet 2025 feet 10 feet 10 feet 6 inches DIP 120 Total 21 3 30 15 Using Hazen -Williams Equation: h = 10.44(length)((flow^1.85)/[(C^1.85)(diameter)^4.8655)} Note: C = 120 for used DI Pipe FLOW (GPM) 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 VELOCITY: V = Q / A OPERATING FLOW (Q) IN GPM = OPERATING FLOW (Q) IN CFS = AREA (A) = SO, VELOCITY (V) IN FPS = 290 0.646 0.196 3.291 69 feet 79 FRICTION LOSS 0.000 0.005 0.018 0.037 0.064 0.096 0.135 0.180 0.230 0.286 0.347 0.414 0.487 0.564 0.647 0.735 0.828 0.927 1.030 1.139 1.252 Table 1-Cont. DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 APPENDIX B PUMP DESIGN POINT SELECTION AND SYSTEM CURVE DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 10 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Project: Watson Rentals Duplex Grinder PS Job Number: 032150-15 Date: 11/8/2021 Jackson County, NC Wet -well and yard piping Maximum Flow Rate: Minimum Water level in wet -well: Finish Grade @ P.S. site: Elevation @ highest point in the system: Static Head: Pipe length inside wet -well: Pipe size inside wet -well: Pumping Distance (equiv. yard piping length): Type of Yard Pipe: C Factor Used: Diameter of Pipe (yard piping): Using Hazen -Williams Equation: Table 4 28 GPM 2021 feet 2026 feet 2050 feet 29 feet 15 feet 2 inches 2109 feet (109+1700+300) PVC /HDPE 140, 120 + 100 2 and 6 inches h = 10.44(length){(flow^1.85)/[(C^1.85)(diameter)^4.8655)} Note: C = 100 for new steel C = 120 for existing PVC C= 140 new HDPE FLOW (GPM) FRICTION LOSS F & S HEAD 0 0.000 29.000 5 0.387 29.387 10 1.395 30.395 15 2.954 31.954 20 5.029 34.029 25 7.599 36.599 30 10.648 39.648 35 14.162 43.162 40 18.130 47.130 45 22.544 51.544 50 27.396 56.396 55 32.678 61.678 60 38.386 67.386 65 44.512 73.512 70 51.053 80.053 75 58.003 87.003 80 65.359 94.359 85 73.116 102.116 90 81.272 110.272 95 89.821 118.821 100 98.762 127.762 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Project: Watson Rentals Duplex Grinder PS Job Number: 032150-15 Date: 11/8/2021 Jackson County, NC Yard piping only- Existing Force Main Maximum Flow Rate: Elevation at point of connection Elevation @ highest point in the system: Static Head: Pumping Distance (equi. yard piping length): Type of Pipe: C Factor Used: Diameter of Pipe (yard piping): Using Hazen -Williams Equation: h = 10.44(length){(flow^1.85)/[(C^1.85)(diameter)"4.8655)) Note: C = 120 for existing PVC FLOW (GPM) 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 VELOCITY: V=Q/A OPERATING FLOW (Q) IN GPM = 28 OPERATING FLOW (Q) IN CFS = 0.062 AREA (A) = 0.196 SO, VELOCITY (V) IN FPS = 0.318 28 GPM 2050 feet 2049 feet -1 feet 1700 feet PVC 120 6 inches FRICTION LOSS 0.000 0.008 0.029 0.062 0.106 0.159 0.223 0.297 0.381 0.473 0.575 0.686 0.806 0.934 1.072 1.217 1.372 1.535 1.706 1.885 2.073 Table 4-Cont. DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Project: Watson Rentals Duplex Grinder PS Job Number: 032150-15 Date: 11/8/2021 Jackson County, NC Yard piping only- New Force Main Maximum Flow Rate: 28 GPM Elevation at exit point of valve box 2023 feet Elevation @ highest point in the system: 2050 feet Static Head: 27 feet Pumping Distance (equi. yard piping length): 300 feet Type of Pipe: HDPE C Factor Used: 140 Diameter of Pipe (yard piping): 2 inches Using Hazen -Williams Equation: h = 10.44(length){(flow^1.85)/[(C^1.85)(diameter)"4.8655)) Note: C = 140 for new HDPE FLOW (GPM) FRICTION LOSS 0 0.000 5 0.226 10 0.814 15 1.724 20 2.936 25 4.436 30 6.216 35 8.267 40 10.584 45 13.160 50 15.993 55 19.076 60 22.408 65 25.984 70 29.803 75 33.860 80 38.154 85 42.682 90 47.443 95 52.434 100 57.653 VELOCITY: V=Q/A OPERATING FLOW (Q) IN GPM = 28 OPERATING FLOW (Q) IN CFS = 0.062 AREA (A) = 0.022 SO, VELOCITY (V) IN FPS = 2.859 Table 4-Cont. DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Project: Job Number: Date: Wet -well piping only Maximum Flow Rate: Minimum water level in wet -well: Exit Elevation of wet -well Static Head: Pipe length inside wet -well: Pipe size inside wet -well: Type of Pipe: C Factor Used: Number Fitting 2 90° Elbow 1 Globe Valve 1 Check valve 1 Tee Watson Rentals Duplex Grinder PS 032150-15 11/8/2021 Jackson County, NC Size (in) Eq. Length (ft) 2 9 2 54 2 20 2 12 Minor Losses: Total Length (including minor losses): 28 GPM 2021.5 feet 2023 feet 1.5 feet 5 feet 2 inches steel 100 Total 18 54 20 12 Using Hazen -Williams Equation: h = 10.44(length){(flow^1.85)/[(C^1.85)(diameter)^4.8655)} Note: C = 100 for new steel Pipe FLOW (GPM) 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 VELOCITY: V = Q / A OPERATING FLOW (Q) IN GPM = OPERATING FLOW (Q) IN CFS = AREA (A) = SO, VELOCITY (V) IN FPS = 28 0.062 0.022 2.859 104 feet 109 FRICTION LOSS 0.000 0.153 0.551 1.167 1.988 3.004 4.209 5.597 7.166 8.911 10.828 12.916 15.172 17.594 20.179 22.926 25.833 28.900 32.123 35.502 39.036 Table 4-Cont. DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Section GRINDER Page 101 Dated JUNE 1999 Superesdes SEPTEMBER 1993 I ri 40- 120 35- 105 30- 90 25- 75 45 10- 30 15 0- ■■■■■■■1■■1■1 ■■■■■■■■■■■!■■■111■■■■!■1■■■■■ SSA ■■■■■1■■■1■■■■■■Il1H ■■II■■■■■■■■■■1■!■■i 525" ■■■���■■■■■■■■■■■■■■■■■■■■ MODEL MAX. IMP 11111 ft`. D7A ■■■■■11 !�\■■■■■■■■■■■■■■■■ IIiii!!!iii!!i11IIIIIi HPG200 550" i.D.7A. ■■■■■■■■■■■\�\ - . ■■�I:_•.■■■■■■■■■IILE■1�.1!■■ 1111■1•11116 !!IliiII!!UIIIiiI!IiUIIIllhJiiIII iiiii�i■iiiiiiil11111\�l11�ii111111■11 11 ■■■■■\., ■■■■■■■■.1�■■■■\�■■■■■■■■■1 1■■■1 ■■■■■■■■IMIRMII ■■■►`NM■■■■►' ■■■■■■ ■■■■ I er\.."_■■■■■■■■■r09■■■■■■\►M■■■■\■■ ■■■�■■i■■ PIIIIMIIIIIIIMPIUMEMEIGNIEMIENNIMMINIMMINEMIMMIEN i ! re■■■■■11EINFA■■■■ I ■M■■■N■■■■E, 111111L5111111111111111MINNESIMM111111111111111Wiliggil"paltliSIIIIIIIIMEPHIMMMINAIMMIMIMERIMEIMIRMEI ■■.10=5n■■■■11��I11r11`I■■M■■■■■■ 11111101.1111111111111..I■■■■■■■■■■ ■■■■■\ 3 lR■■■\GA■ ■\® ■■ IMMIEN ■■■■■■■ !l111101111. 1 , -..'rr 1 \■■■�!■■\�■■■■\■■■■\■■■■■■�I Mem11mm■_ r■1.■■■.N■■■.M■■■.■■■.•■■■■■■ 1111111111911110MISIEREI 1111111111111111111111111111111111111111.1 III L iii hi i 1 q U.S. GPM 7.S 15 22.5 T.7 300 . 37.5 45 52.5 60 M3/HR 2.5 5 7.5 10 12.5 15 Operating point must fall within curve. 'A 3.75" Special Low Head Impeller Conditions of Service: GPM: TDH: HYDROMATIC® DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 APPENDIX C WET -WELL AND PUMP CYCLE INFORMATION DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 11 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 , . PR JECT NAM; Ts A6A/744s IL:: WET.WELL ELEVATIONSSCHEMATICtPAWING (N.T.S.) coRc • TOP OF WET -WELL ELEV. - FlNISHEI) OPADELEV. 7_0 LINE IN INV. ELEV. g itO HIGH WATER ALARM ELEV. LAG PUMPtON ELEV. 7° LEAD PUMP ON ELEV. LO PUMPS OFF ELEV. - 10 '2,1 LOW WATER ALARM ELEV. WET -WELL INV. ELEV. 1- 0 g 'g fammilanik.WION • • DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Watson Rentals. LLC. Jackson County, North Carolina Watson Rentals. LLC. 032150-15 m aJ H Project Name : PUMP CYCLE CALCULATIONS ( Pump Flow) INPUT DATA Ln 00 N if) r1 CO in m5-1 N 0N) tZ L) O a) co L.L. v Ln O E E E 0 o E a1 p n E } E 'E E O- 110 a- ca 0 J LL z CALCULATED RESULTS m C Ln 0 CO 0 m CO Cr) Ln rn dr Ql N Ol N Ol Ln Ln Ln LID LID M M Ln N L -1 N r I r I if) N N M N 1•-• lD Ol M 4 Ln r-I N Ol 00 if) CT) at r4 00 Ql Ln N CO 0 N 00 —I 0 N Ql m Ln Ln O c I 4 lD N N rI N M M 0 t f0 V) DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 APPENDIX D PUMP INFORMATION DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 12 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Pp► PENTAIR HY'i 5W ATC® N'ODEL HPG[X120 SUDMERSOBLE SEWME RN DER PUMP ALSO AVAILABLE FOR HAZiRi}OU►S LOCATION IIPG IIPGX WWW.HYDROMATIC.COM DocuSign Envelope ID: 2C88AOBC-A3B6-4B5F-A8D5-1273034EBD75 SUBMERSIBLE SEWAGE GRINDER PUMP HYfROM,,,nT.- J" MODEL HPG(X)200 Su:TershLe SewEce Grincer 'um] 4, HPG200 Pump / Motor Unit Pumas Characteristics Submersible -Grinder Phase 1 0 3 0 Horsepower 2 2 200V FLA 19.9 9.5 230V FLA 15.6 8.3 460V FLA N/A 4.6 575V FLA N/A 3.3 Service Factor 1.2 Motor Type Oil Cooled Induction Capacitor Start RPM 3450 Temp. Stator Maximum Design 266"F (130°C1 Operation Intermittent Coolant Oil Oil Flash Pt. 390°F Hertz 60 Hz Thermal Overload Bimetallic Temperature Maximum Water 140°F NEMA Design Type L (1 01 (Type B (3 01 Insulation Class F Discharge Size 1-1/4" NPT Unit Weight 82 lbs. Power Cord Type SOOW / SOOW-A, Water Resistant, 600V, 60°C, CSA / UL approved HPG200 Description Motor Housing Materials of Construction 'Material of Construction Cast Iron ASTM-48 Pump Casing Cast Iron ASTM-48 Coolant / Lubricant Dielectric Oil Shaft 416 Stainless Steel Mechanical Shaft Seal Dual: Carbon / Ceramic Type 21 BF1C1 Impeller Valox° (Bronze also available) Cutters 440C Hardened 55-60 Rockwell C Upper Bearing Ball Radial 6203 Lower Bearing Ball Thrust 6306 Fasteners 316 Stainless Steel HPG200 Dimensional Data 14- /32 I-1/4" NPT DISCHARGE 4-44/64" 1-17/32" Top View - Vertical Discharge Standard 1 6-5/8- 1-I/4" NPT DISCHARGE 1-- 2-21/32" 17-3/32' Pump / Motor Unit HPGX200 Pumps Characteristics Submersible -Grinder Phase 1 0 3 0 Horsepower 2 2 208V FLA 16.1 8.2 230V FLA 15.6 7.7 460V FLA N/A 3.9 575V FLA N/A 2.9 Motor Type Oil Cooled Induction RPM 3450 Temperature 140°F Ambient Operation Intermittent Hertz 60 Hz Thermal Overload Bimetallic Temperature Maximum Water 140°F NEMA Design Type L 11 01 (Type B (3 01 Insulation Class F Discharge Size 1-1/4" NPT Unit Weight 105 tbs. Power Cord SOOW, W Description Motor Housing HPGX200 Materials of Construction Material of Construction Class 30 Pump Casing Class 30 Coolant / Lubricant Dielectric Oil Shaft 416 Stainless Steel Mechanical Shaft Seal Seal Faces: Carbon / Ceramic, Seal Body: Stainless Steel, Spring: Stainless Steel, Bellows: Buna-N Impeller Semiopen 5-Vane Brass Cutters 440C Hardened 55-60 Rockwell C Upper Bearing (Radial) Single Row -Ball Lower Bearing (Thrust) Single Row -Ball and Sleeve Fasteners Stainless Steel -3-1/8"4 1.3-39/64-4 6-15/16--^ 4-5/8" 4-5/8' All dimensions in inches. Metric for international use. Component dimensions may vary a 1/8 inch. Dimensional data nut tar construction purpose untess certified. Dimensions and weights are approyinute. 0n/Dfl level adjustable. 2 We reserve the right to make revisions to our product and their specifications about notice. DocuSign Envelope ID: 2C88AOBC-A3B6-4B5F-A8D5-1273034EBD75 iN JZ SUBMERSIBLE SEWAGE GRINDER E. Pu Fe c tur3s A, Two Barrier Seals One epoxy barrier and one compression fitting for maximum protection against wicking and water seepage into the motor housing. B. Bearings The heavy-duty ball bearings, upper (radial) and lower (thrust), are continuously lubricated by ail to ensure long service life. c. Motor Electrical design combines the advantages of high torque output with optimum running efficiency engineered specifically for grinder operation. D. Stator Bolts The stator is secured to the motor housing by means of stator bolts which ensure ease of maintenance if the need ever arises. t . Shaft Standard stainless steel shaft in grinder pump. F. Dual Seals Dual seals for maximum moisture protection. G. Moisture Probe Moisture detection probe. i H. Cutters Exclusive Dual Cutter" design cuts solids to smallest particle size thereby greatly reducing clogging, roping. or binding. Applications: Commercial, Residential, Resort Area Impeller Engineered non-metallic semi -open impeller molded to a bronze insert for greatest torque driving capabilities. Impeller made of high strength Valox® which provides highest level of corrosion resistance and maximum toughness from impact for a wide variety of slurry pumpage. Pump -out vanes preclude material build-up around shaft and seal. Bronze impeller available. WWW.HYDROMATIC.COM 3 DocuSign Envelope ID: 2C88AOBC-A3B6-4B5F-A8D5-1273034EBD75 Section GRINDER Page 202 Dimensional Data — HPG200 i�-K P. PUMP A B C D E F G H I J K HPG200 17-1/4 11-21/32 5-39/64 14-9/32 9-1/4 4-5/8 2-21/32 4-5/8 4-44/64 29/32 4-7/16 ALL DIMENSIONS IN INCHES NOTE: CASTING DIMENSIONS MAY VARY ± 1/8" 00 PENTAIR HYDROMATIC' March © 2017 Pentair plc DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Section GRINDER Page 304 MODEL: HPG(X1 — Submersible Grinder Pumps Electrical Data — HPG(X) R.P.M. 3450 MOTOR TYPE ENCLOSED, OIL COOLED INDUCTION MOTOR DESIGN NEMA TYPE B (30) L (1 a) GENERAL INSULATION CLASS F STATOR WINDING CLASS F MAXIMUM STATOR TEMPERATURE 130°C MOTOR PROTECTION BI-METALLIC, TEMPERATURE SENSITIVE DISC, SIZED TO OPEN AT 120°C AND AUTOMATICALLY RESET @ 30-35°C DIFFERENTIAL, ONE IN SINGLE PHASE, TWO IN THREE PHASE ELECTRICAL RATINGS HEAT SENSOR 24VDC 5AMPS 115VAC 5AMPS 230VAC 5AMPS SEAL FAIL 300VAC 5mA VOLTAGE TOLERANCE ±10% • 2.0 1 G 1.2 HPG: 19.9 51 .8 2.3 9.7 2.4 HPGX: 16.3 230 15.6 48.0 200 3 J 1.2 9.5 33.0 2.1 11.4 2.4 2.0 8.3 28.7 460 HPG:4.6 14.4 HPGX: 4.1 575 3.3 11.5 00 PENTAIR HYDROMATIC' May © 2017 Pentair plc DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Section GRINDER Page 402 Technical Data — HPG(X)200 MODEL: HPG(X1200 — Submersible Centrifugal Grinder Pump Physical Data: DISCHARGE SIZE 2.0" IMPELLER TYPE SEMI -OPEN 5 VANE CABLE LENGTH 20' STANDARD s to s S�%f u�tid Liquid Handling: MAXIMUM LIQUID TEMP. 140°F ACCEPTABLE pH RANGE 6 — 9 SPECIFIC GRAVITY 0,9 — 1.1 VISCOSITY 28 — 35 SSU Temperature: MAXIMUM STATOR 266°F OIL FLASH POINT 390°F HEAT SENSOR Open: Closed: 257°F MAX./239°F MIN. 194°F MAX./149°F MIN. Technical Data: POWER CORD TYPE HPG: SOOW MATERIALS OF CONSTRUCTION MOTOR HOUSING CAST IRON ASTM A-48 CLASS 30 CASING CAST IRON ASTM A-48 CLASS 30 IMPELLER 316 SST/CF8M CUTTERS Stationary: Upper (Axial): Lower (Radial): 440C STAINLESS STEEL HARDENED TO 55-60 ROCKWELL C 440C STAINLESS STEEL HARDENED TO 55-60 ROCKWELL C 440C STAINLESS STEEL HARDENED TO 55-60 ROCKWELL C MOTOR SHAFT 416 STAINLESS STEEL HARDWARE 300 SERIES STAINLESS STEEL 0-RINGS NITRILE MECHANICAL SEALS Standard: UPPER CARBON/CERAMIC/NITRILE, TYPE 21 UPPER BEARING (RADIAL) SINGLE ROW BALL 6203 LOWER BEARING (THRUST) SINGLE ROW BALL 6306 MIN. B-10 BEARING LIFE 50,000 Hrs + PENTAIR HYDROMATIC' May © 2018 Pentair plc DocuSign Envelope ID: 2C88AOBC-A3B6-4B5F-A8D5-1273034EBD75 S.S. FLOAT BRACKET PLc._X 1/ —3" TYP. S.S. LIFTING CABLE BRASS SLIDE AWAY COUPLING 55 fq*;7`i•SiA4'u SS rim BALL CHECK VALVE S.S. TOP GUIDE RAIL BRACKET 2.0 " S.S. PIPE AND FITTINGS S.S. GUIDE RAIL WALL BRACKET S.S. GUIDE RAILS (1 PIECE) S.S. GATE VALVE EXTENSION HANDLE 2.0 " BRASS GA It. VALVE '2.0 " BOLT ON COUPLING S.S. LOWER GUIDE RAIL BRACKET VALID STEELE PLASTICS, INC. 1280 Sturgis Road Conway, AR 72034 (501) 327-5122 Fax (501) 327-0807 TITLE BASIN WITH DUPLEX GUIDE RAILS, S.S. DISCHARGE PROJECT CUSTOMER JOB NO. P.O. NO. SPI125D—SS DWG. NO. DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 APPENDIX E STANDBY GENERATOR INFORMATION DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 13 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Champion Power Equipment 10,000/8,000-Watt Dual Fuel Generator, 201035 4.7 (1068) Reviews Questions & Answers Product Details Specifications Documents $999.99 Home / Tools, Hardware & Garage / Electrical / Generators / Portable Generators / Champion Power Equipment 10,000/8,000-Watt Dual Fuel Generator, 201035 Champion Power Equipment I, 10,000/8,000-Watt Dual Fuel Generator, 201035 4..7 (1068) SKU: 161765299 Reviews Questions & Answers Product Details Specifications Documents $999.99 interest if Paid In Full Within 12 Months Learn More As a Neighbor, you are eligible to earn 1 point per dollar 'an this purchase. Join Now Contactless Curbside / Pickup In Store Sylva NC Change Store Free Contactless Curbside / Pickup in Store Available for Pickup Today Standard Delivery Notice: This item wit ship within 2 days. This product may require up to 2 additional days for order processing priori° shipping. Oversize Delivery - Additional fees may apply. Same Day Delivery Delivered as soon as today if order is placed by 2:00 p.m. You may also schedule your delivery day at checkout. =. • Contactless Curbside / Pickup and Delivery Information Add to list Free standard delivery to your local TSC store. Some exclusions aopiv.. Leam More -powER. PLUS PROTECTIIM Protect Your Purchase We'll fix it, replace it, or reimburse you for it. Learn More 1 Year Service Plan $ 139.99 2 Year Serviee Plan S 239.99 No Protection plan 4.7 (326) Similar Items 4.8 (1096) Guests Also Bought 0 (0) $799.99 Champion Power Equipment 3 (2) 4.8 (1377) 4.6 (178) gew! By continuing, you agree to the use of cookies. Ct DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 Champion Power Equipment (, 10,000/8,000-Watt Dual Fuel Generator, 201035 4.7 (1068) Reviews Questions & Answers Product Details Specifications Documents Yrouuct uenaus $999.99 The Champion Power Equipment 201035 10,000/8,000-Watt Dual Fuel Generator is the perfect combination of versatility and convenience- Whether you need power for your home or next project, this portable generator makes powering your life more convenient than ever. The convenient electric start includes a battery, plus Cold Start Technology ensures a quick start in cold weather. Easily monitor power output and track maintenance intervals with Intelligauge, which allows you to keep track of voltage, hertz and run-time hours. Designed with a low oil shut-off sensor, this compact generator includes 1.2-quarts of 10W-30 oil. Operate your Dual-Fut.,' generator right out of the box on gasoline or propane, and easily switch fuels with our patented fuel selector switch that allows for safe switching between fuel; sources. Using gasoline, the 458cc Champion engine produces 10000 starting watts and 8000 running watts, and will run for 10 hours at 50% load when the 7.7- gallon fuel tank is full. It produces 9000 starting watts and 7200 running watts, and will run for 5 hours at 50% load when using a 20-pound propane tank. • Dual Fuel - Operate your 8000-watt portable generator right out of the box on either gasoline or propane, plus the unit holds 1.2-quarts of oil (included) and has a low oil shut-off switch • Electric start - Power up the 458cc Champion engine with the handy rocker switch, battery included • Intelligauge - Keep track of voltage, hertz and run-time hours to easily monitor output and track maintenance intervals with this compact generator • Powerful - At 10000 starting watts and 8000 running watts on gasoline and 9000 starting watts and 7200 running watts on propane. trust Volt Guard'" to protect your generator from electrical voltage spikes • Champion Support - Duel fuel generator includes 3-year limited warranty with free lifetime technical support from dedicated experts Specifications Specification Description Brand Champion Power Eauioment suet Weiaht 203 Ib. oduct Length 28.7 in. Warranty 3 Year Limited Warrant;-, ':moeraoe 83.3 A "uto Idle Control No Automatic Voltaoe Regulation Yes Control Panel Yes Country of Origin imports Decibel Rating 74 t b.=, Duty 8.000 W Engine Brand Champion a^ine Displacement 458 cc Fuel Capacity 7.7 gal. Fuel Gauge Fuel Tank Capacity Fuel Type Full Load Fuel Consumption Horsepower 0 W Yes /.I tra,. Propane 7.7-gallon 3, continuing. you agree to the use of cocies. 2/6 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 APPENDIX F SITE DEVELOPMENT AND FLOOD MAPS DESIGN CALCULATIONS V&M Project No. 032150-15 11/21 Page 14 DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 .etVt,A - Horn... • Intera€trve Map NC NC L)LU Public Wa... NLL}hU Flan Ff€tie... I ArcfilS - New Bern... ik DocuSign gip 4019-NLiHII U... qp, 4LI. LU-LJ-511j -... 1LK)I bad item list 'f Loagle flaps deanhelstrom rah... LANK :: '_ocal Water... 1 Mi 11 AP" 9''t — Map Theme IF 411 2,025.5 Who Am I : General Public • V' ! Lither rayon :e= Map Location Flood Zone: FI ood Source: Tuckasegee River Base Flood Elevation: 2021-1 ft 0 Less 10Year Flood Elevation 201.3_1 ft 0 25 Year Flood Elevation 2015.1 ft 0 50Year Flood Elevation 2018.5 ft tal 100Year Flood Elevation 2021.1 ft 0 100Year Future Conditions N/A 500'Year Flood Elevation 2026_5 ft County: Jackson Politi€alArea: Jackson County CID: 370282 -.t ► Risk Information ► Financial Vulnerability ► flood Insurance ► 115 Reports ► Map Export ► Data Export DocuSign Envelope ID: 2C88A0BC-A3B6-4B5F-A8D5-1273034EBD75 p htt p s ?i fri s. n c.gov/fri s/ Ind ex aspx?PEPS = D99&ST= N C &user= G e ne ra l%20 Publ is :o^nectVM-+io-m...r1^ Interactive Map NC NC DEQ: Public Wa,.. NCDEQ Plan Betide... 4rcGIS - New Bern... 4^ DocuSign 4019135-NCDCT 0... E} 4020332-LI-5713 -. TDOT bid iten-. list Google Maps deanhelstrom@yah... DWR :: Local Water... Search it County: DFI RM' Places: Streams: Address: Coordinates: Latitude-Northing-Y: Lo ngi to d e-Fast ing-X: Jackson Lat - Lon (Decimal Degrees) .. 35.341022857639125 -83.22909422099671 cL 0 0 `_ c I Who Am I : General Public / T M Otherfav Effective 7 0 crick the map toview information Map Location (Zone X) Minimal Flood Risk Flood Zone: Flood Source: Tucka_eEee River Base Flood Elevation: N/A More County: Jackson PoliticalArea: Jackson County CID: 370282 Panel: 7630 2 Download Map 1'7umber: 3700763000J Panel Effective Date: 4119/2010 Latitude: 35.34103 Longitude: -83.22911 Address locations are approximate. 16 Rustic Ln,SvIva, NC, 28779 ► Risk Inforrnatio, ► Financial Vulnerability ► Flood Insurance ► FIS Reports ► Map Export ► Data Export DellCommandUpdate 3 uadates are ready to lns,.a-I View Deta