SYMBOLS AND
ABBREVIATIONS
ABC
AGGREGATE BASE COURSE
O
EXISTING CURB INLET
ALUM
ALUMINUM
❑
EXISTING DROP INLET / YARD INLET
ASSY
ASSEMBLY
a
EXISTING FLARED END SECTION
B-B
BACK TO BACK
-6-
EXISTING FIRE HYDRANT
BOA
BLOW -OFF ASSEMBLY
M0
EXISTING BLOW -OFF ASSEMBLY
C&G
CURB AND GUTTER
EXISTING GATE VALVE
CFS
CUBIC FEET PER SECOND
D
EXISTING REDUCER
CI
CURB INLET
EXISTING WATER METER
C/L
CENTER LINE
O
EXISTING MANHOLE / JUNCTION BOX
CO
CLEAN OUT
Oa
EXISTING CLEAN OUT
COM
COMMUNICATION
0
EXISTING POWER POLE
CONC
CONCRETE
C
EXISTING GUY WIRE
CT
COURT
❑
EXISTING TELEPHONE PEDESTAL
CU
COPPER
3�_
EXISTING LIGHT POLE / AREA LIGHT
DCV
DOUBLE CHECK VALVE
EXISTING SIGN
DDCV
DOUBLE DETECTOR CHECK VALVE
NEW CURB INLET
DEFL
DEFLECTION
NEW GRATE INLET/YARD INLET
DI
DROP INLET
,
NEW FLARED END SECTION
DIP
DUCTILE IRON PIPE
NEW FIRE HYDRANT
DRAIN
DRAINAGE
NEW BLOW -OFF ASSEMBLY
N
NEW GATE VALVE
DR
DRIVE
NEW REDUCER
EASE
EASEMENT
NEW WATER METER
ELEC
ELECTRIC
_
1 • 1
NEW TEE
EOP
EDGE OF PAVEMENT
I -I
NEW PLUG
EXIST
EXISTING
•
NEW MANHOLE
FES
FLARED END SECTION
Q
NEW CLEAN OUT
FH
FIRE HYDRANT
_W_
NEW SIGN
FM
FORCE MAIN
o
IRON PIPE
FT
FEET
BENCHMARK
FT/SEC
FEET PER SEC
03
STORM STRUCTURE LABEL
GALV
GALVANIZED
GV
GATE VALVE
BLOCK AND GRAVEL INLET PROTECTION
HCR
HANDICAP RAMP
®®®®
INV
INVERT
SILT FENCE INLET PROTECTION
L
LENGTH
LF
LINEAR FEET
EXCAVATED INLET PROTECTION
LP
LIGHT POLE
LT
LEFT
MH
MANHOLE
SEDIMENT BASIN
MIN
MINIMUM
OHE
OVERHEAD ELECTRIC
RISER BASIN
PAVE
PERM
PAVEMENT
PERMANENT
ROCK DAM
PP
POWER POLE
- -c- - -o- -
EXISTING GAS LINE
PVC
POLYVINYL CHLORIDE
- con+ - --con+ -
EXISTING COMMUNICATIONS LINE
R
RADIUS
- -UT- - -UT- -
EXISTING UNDERGROUND TELEPHONE
R/W
RIGHT-OF-WAY
- -UE- - -UE- -
EXISTING UNDERGROUND ELECTRIC
RED
REDUCER
- - oHE - - - oHE -
EXISTING OVERHEAD ELECTRIC
RPZ
REDUCED PRESSURE ZONE
- -W- - -W- -
EXISTING WATER LINE
RT
RIGHT
-FM-FM-FM-
EXISTING SANITARY SEWER FORCE MAIN
S
SLOPE
- -ss- - -ss- -
EXISTING SANITARY SEWER
SS
SANITARY SEWER
---------
EXISTING STORM DRAINAGE
STA
STATION
NEW STORM DRAINAGE
T
TANGENT
- - - -
STREAM
TDD
TEMPORARY DIVERSION DITCH
• --- --
NEW WATER LINE
TELE
TELEPHONE
-<-<-<-
NEW SANITARY SEWER
TSB
TEMPORARY SEDIMENT BASIN
-FM-FM-Fu-
NEW SANITARY SEWER FORCE MAIN
TSD
TEMPORARY SLOPE DRAIN
NEW GAS MAIN
UG
UNDERGROUND
GL
GRASSED LINED DITCH/CHANNEL
W
WIDTH
JM
JUTE MATTING LINED DITCH/CHANNEL
W/L
WATER LINE
P
PYRAMAT LINED DITCH/CHANNEL
WM
WATER METER
C
LIMITS OF CUT SLOPE
YI
YARD INLET
F
LIMITS OF FILL SLOPE
SILT FENCE
-TF X TF-
TREE FENCE
COMBINATION SILT/ TREE FENCE
DIVERSION DITCH
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE MUNICIPALITY STANDARDS,
SPECIFICATIONS, AND DETAILS. WORK IN THIS PROJECT SHALL ALSO CONFORM TO THESE PLANS, THE
LATEST EDITIONS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) ROAD AND BRIDGE
SPECIFICATIONS, THE ROAD AND BRIDGE STANDARDS, THE NORTH CAROLINA EROSION AND SEDIMENT
CONTROL HANDBOOK, THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL REGULATIONS, THE FINAL
GEOTECHNICAL REPORT, AND GENERAL DESIGN STANDARDS. IN THE EVENT OF CONFLICT BETWEEN ANY OF
THESE STANDARDS, SPECIFICATIONS, OR PLANS, THE MOST STRINGENT SHALL GOVERN.
2. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR TRENCH SAFETY DURING ALL PHASES OF
CONSTRUCTION.
3. THE LOCATION AND SIZE OF EXISTING UTILITIES AS SHOWN IS APPROXIMATE ONLY. THE CONTRACTOR IS
RESPONSIBLE FOR HORIZONTALLY AND VERTICALLY LOCATING AND PROTECTING ALL PUBLIC OR PRIVATE
UTILITIES WHICH LIE IN OR ADJACENT TO THE CONSTRUCTION SITE. AT LEAST 72 HOURS PRIOR TO ANY
DEMOLITION GRADING OR CONSTRUCTION ACTIVITY THE CONTRACTOR SHALL NOTIFY THE NORTH CAROLINA
ONE -CALL UTILITIES LOCATION SERVICE ULOCO AT 1-800-632-4949 FOR PROPER IDENTIFICATION OF
( 1
EXISTING UTILITIES WITHIN THE SITE.
4. THE CONTRACTOR SHALL SALVAGE AND PROTECT ALL EXISTING POWER POLES, SIGNS, MANHOLES,
TELEPHONE RISERS, WATER VALVES, ETC. DURING ALL CONSTRUCTION PHASES. THE CONTRACTOR SHALL
REPAIR, AT HIS OWN EXPENSE, ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION.
5. TRAFFIC CONTROL ON PUBLIC STREETS SHALL BE IN CONFORMANCE WITH THE TRAFFIC CONTROL PLAN,
THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, AND AS FURTHER DIRECTED BY CITY AND STATE
INSPECTORS.
6. ANY DISCREPANCIES FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS AND SITE CONDITIONS OR ANY
INCONSISTENCIES OR AMBIGUITIES IN DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO
THE ENGINEER, IN WRITING, WHO SHALL PROMPTLY ADDRESS SUCH INCONSISTENCIES OR AMBIGUITIES.
WORK DONE BY THE CONTRACTOR AFTER HIS DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES, OR
AMBIGUITIES SHALL BE DONE AT THE CONTRACTOR'S RISK.
SPINNING
MILL LOFTS
AT EAST VILLAGE
PHASE 1
CONSTRUCTION DRAWINGS - SUBMITTED
TOWN OF CLAYTON
JOHNSTON COUNTY
DEVELOPER:
SPINNINNG MILL INVESTMENTS, LLC
P.O. BOX 566
GREENVILLE, NC 27835
TELEPHONE: (252) 752-7101
CONTACT: THOMAS TAFT, JR.
11-11-21
NORTH CAROLINA
VICINITY MAP
1"= 1,000'
PRE PARS D BY.
I n
BIZ111:1
BASS, NIXON & KENNEDY, INC.
CONSULTING ENGINEERS
6310 CHAPEL HILL ROAD, SUITE 250
RALEIGH, NORTH CAROLINA 27607
TELEPHONE: (919)851-4422 or (800)354-1879
FAX:(919)851-8968
www.BNKine.com
CERTIFICATION NUMBERS: NCBELS (C-0110)
NCBOLA (C-0267)
CONSTRUCTION NOTES
7. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE
CONTRACTOR SHALL ARRANGE THE MEETING WITH THE TOWN OF CLAYTON ENGINEERING DEPARTMENT.
8. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL REQUIRED PERMITS AND APPROVALS PRIOR TO
COMMENCING CONSTRUCTION.
9. ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE, AND AS SHOWN ON THESE PLANS. THE
CONTRACTOR SHALL MAINTAIN ADEQUATE SITE DRAINAGE DURING ALL PHASES OF CONSTRUCTION. THE
CONTRACTOR SHALL USE SILT FENCES (OR OTHER METHODS APPROVED BY THE ENGINEER AND
APPLICABLE MUNICIPALITY) AS REQUIRED TO PREVENT SILT AND CONSTRUCTION DEBRIS FROM FLOWING
ONTO ADJACENT PROPERTIES. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, OR
LOCAL EROSION, CONSERVATION, AND SILTATION ORDINANCES. CONTRACTOR SHALL REMOVE ALL
TEMPORARY EROSION CONTROL DEVICES UPON COMPLETION OF PERMANENT DRAINAGE FACILITIES AND THE
ESTABLISHMENT OF A STAND OF GRASS OR OTHER GROWTH TO PREVENT EROSION.
10. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE COMPACT AND MOISTURE CONDITION
ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEER'S SPECIFICATIONS. THE FILL MATERIAL TO BE USED
SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT.
11. MATERIALS USED TO CONSTRUCT EMBANKMENTS FOR ANY PURPOSE, BACKFILL AROUND DRAINAGE
STRUCTURES, OR IN UTILITY TRENCHES FOR ANY OTHER DEPRESSION REQUIRING FILL OR BACKFILL SHALL
BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST AS SET
OUT IN ASTM STANDARD D698. STONE BACKFILL SHALL BE COMPACTED TO 95% MAXIMUM DENSITY AS
DETERMINED BY THE MODIFIED PROCTOR TEST AS SET OUT IN ASTM STANDARD D1557. THE CONTRACTOR
SHALL, PRIOR TO ANY OPERATIONS INVOLVING FILLING OR BACKFILLING, SUBMIT THE RESULTS OF THE
PROCTOR TEST TOGETHER WITH A CERTIFICATION THAT THE SOIL TESTED IS REPRESENTATIVE OF THE
MATERIALS TO BE USED ON THE PROJECT. TESTS SHALL BE CONDUCTED BY A CERTIFIED MATERIALS
TESTING LABORATORY AND THE CERTIFICATIONS MADE BY A LICENSED PROFESSIONAL ENGINEER
REPRESENTING THE LABORATORY.
12. PROPOSED CONTOURS AND GUTTER GRADIENTS ARE APPROXIMATE. PROPOSED SPOT
ELEVATIONS AND ROADWAY PROFILE&SU PERE LEVATIONS ARE TO BE USED IN CASE OF DISCREPANCY
ENGINEERS:
BASS, NIXON AND KENNEDY, INC.
6310 CHAPEL HILL ROAD, SUITE 250
SHEET INDEX
SHEET No.
SHEET TITLE
COVER SHEET
C1.0
EXISTING CONDITIONS PLAN
C1.1
OVERALL SITE PLAN
C1.2
ENLARGED SITE PLAN
C1.3
ENLARGED SITE PLAN
C2.1
UTILITY PLAN
C2.2
UTILITY PLAN
C3.1
GRADING AND DRAINAGE PLAN
C3.2
GRADING AND DRAINAGE PLAN
C3.3
STORM DRAINAGE CALCULATIONS
C3.4
SCM # 1 PLAN AND DETAILS
C3.5
SCM # 2 PLAN AND DETAILS
C3.6
EROSION CONTROL PLAN STAGE 1
C3.7
EROSION CONTROL PLAN STAGE 1
C3.8
EROSION CONTROL PLAN STAGE 2
C3.9
EROSION CONTROL PLAN STAGE 2
C4.1
SEWER OUTFALL A PLAN AND PROFILE
C4.2
8" PVC WATERLINE PLAN AND PROFILE
C4.3
8" PVC WATERLINE PLAN AND PROFILE
C5.1
DETAILS - SITE
C5.2
DETAILS - WATER
C5.3
DETAILS - SEWER
C5.4
EROSION CONTROL DETAILS
C5.5
EROSION CONTROL DETAILS
C5.6
EROSION CONTROL DETAILS
L1.0
OVERALL LANDSCAPE PLAN
L1.1
LANDSCAPE PLAN NORTH
L1.2
LANDSCAPE PLAN SOUTH
L1.3
MILL BUILDING LANDSCAPE PLAN
L1.4 DETAILS
WATER LINE
I LF
FDC
I EA
1 3" Water Meter
I EA
1 3" Service line PVC
I LF
1 4" Fire Service Line PVC
I LF
1 6" DIP Service Line
LF
I Fire Hydrants
EA
8" PVC MAIN
12,371.67
1 9.001
1 9.001
1748.171456.43
163.03
8
TOTAL
12,371.67
1 9.00
1 9.00
748.17
456.43
163.031
8
Storm Drain Pipe
LF
EA
EA
I EA
EA
EA
15" RCP
2,193.77
Curb Inlets
32
Junction Box
2
Wet Pond Outlet Structures
Flared End Sections
Yard Inlets
14
18" RCP
954.88
4' x 4' Structure
2
15" FES
1
24" RCP
848.20
24" FES
4
36" RCP
389.62
36" FES
1
I Sanitary Sewer Pipe I LF
8" C-900 PVC 78.40 Manholes EA
50.93 4' Manhole 1
262.64 5' Extended Base 7
219.18
123.98
TOTAL 1 735.13 8
8" 401 Lined DIP
139.70
141.63
244.38
TOTAL 525.71
1 6" PVC Service Line 1 1,438.03 1 6" Clean Outs 1 24 1 1
TOTAL
8.03
24
STREET
LF
I Sidewalk
LF
GreenwayTrail
LF
Greenway Trail
LF
A
692.81
6 ' wide conc. side%
6,198.96
8' wide conc. sidewz
1,129.65
10' wide asphalt sidewa
160.38
B
1,400.57
Mill Street
1,067.22
D
326.85
1
365.59
L
214.70
TOTAL
14,067.741
16,198.9611,129.65
EEU
RALEIGH, NORTH CAROLINA 27607
TELEPHONE: (919) 851-4422
FAX: (919) 851-8968
CONTACT: MARTY D. BIZZELL, PE, CPESC
EMAIL: MARTY.BIZZELL@BNKINC.COM
13. THE CONTRACTOR SHALL REVIEW, VERIFY AND COORDINATE ALL DIMENSIONS SHOWN ON PLANS, INCLUDING
THE HORIZONTAL AND VERTICAL LOCATION OF CURB INLETS AND GRATE INLETS AND ALL UTILITIES
CROSSING THE STORM SEWER PRIOR TO STARTING PROJECT.
14. ALL CURB JOINTS SHALL EXTEND THROUGH THE CURB. MINIMUM LENGTH OF OFFSET JOINTS AT RADIUS
POINTS IS 1.5 FEET. ALL JOINTS SHALL BE SEALED WITH JOINT SEALANT.
15. ALL HANDICAP RAMPING, STRIPING, AND PAVEMENT MARKINGS SHALL CONFORM TO ADA REQUIREMENTS
AND THE NORTH CAROLINA STATE BUILDING CODE, VOL. 1-C ACCESSIBILITY CODE.
16. OWNER SHALL PROVIDE FENCING AND OTHER SAFETY MEASURES NECESSARY IN AND AROUND ANY
PROPOSED STORMWATER MANAGEMENT MEASURES (PONDS, WETLANDS, ETC.) OBTAINING PROPER PERMITS
SHALL BE THE RESPONSIBILITY OF THE OWNER.
17. RETAINING WALLS EXCEEDING 30 INCHES IN HEIGHT SHALL INCLUDE FALL PROTECTION IN THE FORM OF A
HANDRAIL OR FENCING ON THE HIGH SIDE OF THE RETAINING WALL.
18. PROPER COMPACTION OF ALL FILL SOILS PLACED ON SITE SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR. COMPACTION SHALL BE ADEQUATE TO SUPPORT THE PROPOSED USE OF AREAS IN WHICH
FILL SOILS ARE PLACED. THE CONTRACTOR SHALL HIRE A GEOTECHNICAL ENGINEER TO TEST AND VERIFY
THAT COMPACTION IS ADEQUATE FOR THE PROPOSED USE OF IN THE AREA OF FILL PLACEMENT.
19. ALL ASPECTS OF THIS PROJECT SHALL BE IN FULL COMPLIANCE WITH CURRENT ADA STANDARDS. IF THE
CONTRACTOR NOTES ANY ASPECTS OF THE PROJECT WHICH ARE NOT IN COMPLIANCE, THE ENGINEER
SHALL BE NOTIFIED PRIOR TO ANY FURTHER WORK BEING PERFORMED. ANY WORK PERFORMED AFTER
THE CONTRACTOR NOTES SUCH A NON COMPLIANCE IS SUBJECT TO REMOVAL AND REPAIR AT THE
CONTRACTOR'S EXPENSE.
20. THE CONTRACTOR OR OWNER SHALL EMPLOY A GEOTECHNICAL ENGINEER TO TEST ALL EMBANKMENTS AND
FILL PLACEMENT FOR PROPER COMPACTION. PROPER COMPACTION SHALL BE PER THE GEOTECHNICAL
ENGINEER'S RECOMMENDATIONS OR THESE PLANS, WHICHEVER IS MORE STRINGENT. EMBANKMENTS FOR
PONDS SHALL BE PLACED IN 6 INCH LOOSE LAYERS AND SHALL BE COMPACTED TO A DENSITY OF NO
LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR -
TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. THE
CONTRACTOR SHALL TAKE PHOTOGRAPHS OF THE OUTLET STRUCTURE AT ALL PHASES OF
INSTALLATION AND SHALL RETAIN WITH GEOTECHNICAL TESTING DATA. THE CONTRACTOR SHALL ALSO
RETAIN ALL SHIPPING RECORDS AND SPECIFICATIONS FOR THE OUTLET STRUCTURE MATERIALS AND
STRUCTURES. ALL OF THE ABOVE DATA MAY BE REQUIRED AS PART OF THE MUNICIPALITY AS -BUILT
PROCESS AND SHALL BE MADE AVAILABLE TO THE ENGINEER UPON REQUEST. THE CONTRACTOR AND
OWNER SHALL HAVE DOCUMENTATION OF THESE TESTS AVAILABLE UPON REQUEST.
21. RETAINING WALLS SHOWN HEREIN SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER WITH
EXPERIENCE DESIGNING RETAINING WALLS. AT LEAST 14 DAYS PRIOR TO BEGINNING CONSTRUCTION OF
RETAINING WALLS, THE CONTRACTOR SHALL CONTACT THE OWNER'S GEOTECHNICAL ENGINEER TO
SCHEDULE AND COORDINATE ALL APPROPRIATE INSPECTIONS, TESTING, AND VERIFICATION NECESSARY
DURING RETAINING WALL CONSTRUCTION. THE GEOTECHNICAL ENGINEER SHALL PROVIDE CONTINUOUS
INSPECTION, TESTING AND VERIFICATION FOR THE DURATION OF RETAINING WALL CONSTRUCTION. PROPER
SCHEDULING, EXECUTION, AND RECORD KEEPING FOR ALL REQUIRED INSPECTIONS, TESTING, AND
VERIFICATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. SUCH RECORDS SHALL BE RETAINED
AND SHALL BE PROVIDED TO THE OWNER AND BASS, NIXON & KENNEDY, INC. ALL MONITORING,
TESTING, AND VERIFICATION SHALL CONFORM TO THE MOST RECENT VERSION OF THE INC BUILDING CODE
CHAPTER 18, SECTION 1806 OR THE WALL DESIGN ENGINEER'S SPECIFICATIONS, WHICHEVER IS MORE
STRINGENT.
22. ALL RETAINING WALLS CONSTRUCTED ON THIS SITE WILL REQUIRE A BUILDING PERMIT PRIOR TO THE
START OF CONSTRUCTION.
Town of Clayton
Approved for Construction
Signature: Date:
To Engneer
Initials/Date
Engineering:
Stormwater:
Planning:
Fire:
Town of Clayton Engineering must be contacted at a
minimum 48 hours prior to the commencement of
construction activities. The Town of Clayton will not be
responsible for errors and/or omissions on these
approved set of plans.
0
z
a
0
z
0
H
V
0
z
0
LU
r
a
2
IL
♦LU
V
a
J
\J
F_
W
a
LU
F_
a
V`♦
r
0
J
J
J
V
z
z
z
FL
U)