HomeMy WebLinkAboutWQ0018645_Permit (Issuance)_20000713State of North Carolina
Department of Environment
and Natural Resources
Division of Water Quality
James B. Hunt, Jr., Governor
Bill Holman, Secretary
Kerr T. Stevens, Director
THOMAS S. SPEIGHT, JR., PE, PLS
PWC OF THE CITY OF FAYETTEVILLE
PO DRAWER 1089
FAYE I hVILLE, NC 28302-1089
Dear Mr. Speight:
RECEiVED AVA
CDENR
JUL 1 3 2000
FAYETTEVILLE
REG. OFFICE
July 13, 2000
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
Subject: Permit No. WQ0018645
PWC of the City of Fayetteville
Hope Mills Crossing, Bi-Lo Store #404
Wastewater Collection System
Cumberland County
In accordance with your application received June 20, 2000, attached is Permit No. WQ0018645,
dated July 13, 2000, to PWC of the City of Fayetteville for the construction and operation of the subject
wastewater collection extension.
This permit shall be effective from the date of issuance until rescinded and you shall be subject
to the conditions and limitations as specified in the North Carolina Gravity Sewer Design Criteria
adopted February 12, 1996 and the attached permit.
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted
for the construction and operation of approximately 684 linear feet of 8-inch gravity sewer to serve
53,063 ft2 of retail space as part of the Hope Mills Crossing, Bi-Lo Store #404 project, and the discharge
of 6,368 GPD of collected domestic wastewater into PWC of the City of Fayetteville's existing
sewerage system, pursuant to the application received June 20, 2000, and in conformity with the North
Carolina Gravity Sewer Design Criteria.
The sewage and wastewater collected by this system shall be treated in the PWC of the City of
Fayetteville Wastewater Treatment Facility (NPDES Permit No. NC0050105) prior to being discharged
into the receiving stream.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding.
The issuance of this permit does not preclude the Permittee from complying with any and all
statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local,
state, and federal) which have jurisdiction.
1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 715-6048
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
If you need additional information concerning this matter, please contact Kristin Miguez at
(919) 733-5083 extension 524.
Sincerely,
Kerr T. Stevens
cc: Cumberland County Health Department
Fayetteville Regional Office, Water Quality Section
Mitchell Engineering, Inc.
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
GRAVITY SEWER COLLECTION SYSTEMS PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the facilities are constructed in accordance with the
conditions of the Division of Water Quality Gravity Sewer Design Criteria adopted February 12,
1996.
2. This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The facilities must be properly maintained and operated at all times.
4. This permit is not transferable. In the event there is a desire for the facilities to change ownership,
or there is a name change of the Permittee, a formal permit request must be submitted to the
Division of Water Quality (Division) accompanied by an application fee, documentation from the
parties involved, and other supporting materials as may be appropriate. The approval of this request
will be considered on its merits and may or may not be approved.
5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing
utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the
State.
6. Upon completion of construction and prior to operation of this permitted facility, a certification
and a copy of the record drawings (i.e., as constructed plans) must be received from a professional
engineer certifying that the permitted facility has been installed in accordance with the Division of
Water Quality Gravity Sewer Design Criteria adopted February 12, 1996, and other supporting
materials. If this project is to be completed in phases and partially certified, you shall retain the
responsibility to track further construction approved under the same permit, and shall provide a final
certificate of completion once the entire project has been completed. A copy of the record
drawings, indicating the facilities constructed in the phase being certified, shall be submitted with
each partial certification. Mail the Certification and one (1) copy of the "Record Drawings" to the
Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617.
7. A copy of the Record Drawings shall be maintained on file by the Permittee for a minimum of five
years from the date of the completion of construction.
8. Failure to abide by the conditions and limitations contained in this general sewer permit or the
North Carolina Gravity Sewer Design Criteria may subject the Permittee to an enforcement action
by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C.
1
9. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance
conditions, the Permittee shall take immediate corrective action, including those as may be required
by this Division, such as the construction of additional or replacement wastewater collection
facilities.
10. Noncompliance Notification:
The Permittee shall report by telephone to the Fayetteville Regional Office, telephone number (910)
486-1541, as soon as possible, but in no case more than 24 hours or on the next working day,
following the occurrence or first knowledge of the occurrence of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any failure of a sewer line resulting in a by-pass directly to receiving waters without treatment
of all or any portion of the influent to such station or facility.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five (5) days following first knowledge of the occurrence. This report must outline the actions
taken or proposed to be taken to ensure that the problem does not recur.
Permit issued this the thirteenth day of July, 2000
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
tt9t-]1(errT. Stevens, Dire o�'t rDivision of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0018645
2
Permit No. WQ0018645
July 13, 2000
ENGINEER'S CERTIFICATION
Partial Final
I, , as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the
project, for the
Project Name Location and County
Permittee hereby states that, to the best of my abilities, due care and diligence was used in the
observation of the construction such that the construction was observed to be built within substantial
compliance of this permit, the certificate of coverage, the North Carolina Gravity Sewer Minimum
Design Manual, and other supporting materials.
North Carolina Professional Engineer's seal, signature, and date:
The above Engineer's Certification must be completed and submitted to the address below with one (1)
copy of the "Record Drawings" (i.e., as -constructed plans) of the wastewater collection system. This
project shall not be considered complete nor allowed to operate until this Engineer's Certification and the
"Record Drawings" plans have been submitted. Any wastewater flow made tributary to the wastewater
collection system prior to completion of this Engineer's Certification shall be considered a violation of
the permit and shall subject the Permittee to appropriate enforcement actions.
NORTH CAROLINA DIVISION OF WATER QUALITY
WATER QUALITY SECTION
NON -DISCHARGE PERMITTING UNIT
1617 MAIL SERVICE CENTER
RALEIGH, NORTH CAROLINA 27699-1617
3
06/27/2000 09:35 919-715-6048
DWQ NON DISCHARGE BR
PAGE 01/01
TO
PROCEDURE 4 REQUEST FORM
DATE: (l Z'16 Q)
FROM: Paul Rawls, Water Quality Supervisor
Fayetteville Regional Office, Water Quality Section
Kristin Miguez
Non -Discharge Permitting Unit
State Engineering Review Group
(919) 733-5083 x524
Fax (919) 715-6048
Application Number: Dn l L 5 County:
Applicant: CANI WI/1 ( Lt P c,
Project Name: Mi (t5 ,4/1 rLoJ Bi- Lo gDi-P 41- 4 pc4-
Receiving Facility: c-u\tC kv(I (Q PVC Permit # N L DD 5 b(Q S
Flow Volume: 311 GPD Flow Type: 4�Dom. Com. ,Ind.
Engineer: `Dap j- ► s Mi4-We (( SOC project? yes no
Approval: ' Denial:
Comments:
Regional Signature:.te47 - v 1-00
Application Number: County:
Applicant:
Project Name:
Receiving Facility: Permit #
Flow Volume: GPD Flow Type: Dom. Com. Ind.
Engineer: SOC project? yes no
Approval: Denial:
Comments:
Regional Signature:
•
* * * COMMUNICATION RESULT•REPORT ( JUL. 7.2000
FILE MODE OPTION
258 MEMORY TX
ADDRESS (GROUP)
19197156048
016 ) * * *
TTI ENVIRONMENTAL MGMT
RESULT PAGE
• OK
P. i
P. 2/2
REASON FOR ERROR
E-1) HANG UP OR LINE FAIL
E-3) NO ANSWER
06/26/2006 08:3S 919-715-6048
6-.) FROM:
TO
E-2) BUSY
E-4) N0 FACSIMILE CONNECTION
DWQ NON DISCHARGE AR
PROCEDURE 4 REQUEST FORM
DA
PAGE 01/81
Paul Rawls, Water Quality Superviscii
ttIVED
Fayetteville Regional Office, Water Qusli
Kristin Miguez
Ton -Discharge Peitting Unit
State Engineering Review Group
(919)733-5083 x524
Fax (919) 715-6048
• Application Number:
Applicant:
Project Name:
Receiving Facility:
now Voluriie: GED Flo
Engineer: J4irnf5 A j a/ Dciiru 5
Approval: - 1" Denial:
IN 262000
FAYETIEVILIE
REG. OFFICE
41,
e: OW. Cosa, w,__. nd.
SOC project? ___.yes _no