Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0087998_Report_20211129
SM A 0 A An 4 Essential Utilities Company November 18, 2021 RECEIVED w 2 2 2021 NCDENR- DWR-Water Quality Permitting Attn: Min Xiao, PE NCDEQIDWRINNDtS 1617 Mail Service Center Raleigh, North Carolina 27699 Re: Generic Authorization to Construct Request for Portable Membrane Bioreactor Aqua North Carolina, Inc. (Aqua NC) Aqua NC currently owns and operates 58 wastewater treatment plants (WWTPs). Almost all of these WWTPs are permitted for operation through NCDENR-DWR. Many of these wastewater treatments are constructed of a coated steel and require periodic maintenance to blast and coat the steel due to age-related coating conditions. Several of these are smaller wastewater treatment plants without redundant aeration and clarification zones, and it is difficult to complete this maintenance while keeping the same facilities in service for wastewater treatment. In 2021, two of these facilities are being recoated. One is the Beachwood WWTP which is currently being recoated while being temporarily interconnected with another wastewater treatment facility. The second wastewater treatment plant, Harbor Estates, has two aeration tanks and a single clarifier. The dual aeration zones allowed each zone to be individually drained, cleaned, blasted, and coated while the other zone was operated. A coating was applied with an exceptionally short drying time to submergence, with final curing after submergence. Aqua NC had planned to operate the aeration zones as a manual batch reactor while completing the clarifier rehabilitation, but fortunately due to the low flowrate and available storage at the wastewater treatment plant this operation method was unnecessary. We will be monitoring this coating and if it performs as expected it may be used for future rehabilitation projects. Many other plants will not have this option. requirements for the On July 28, 2021, Aqua NC was provided with the following submittal re q portable membrane bioreactor package plant. Our response for each item is provided in italics below: • Detailed introduction and drawing for the MBR plant, and how the MBR plant will be setup. Attached please find design calculations for a typical portable Membrane Bioreactor wastewater treatment plant as provided for rental through Ovivo. Aqua Texas is currently operating one of these temporary Ovivo MBRs while replacing an existing wastewater treatment plant — Barton Creek Lakeside. I have personally inspected this wastewater treatment plant in operation and discussed its start-up with the Aqua Texas field staff, and it is operating well. These facilities provide a greater 202 MacKenan Court, Cary, NC 27511 • 0: 919.467.8712 • F: 919.460.1788 • AquaAmerica.com level of control than a conventional wastewater treatment plant, including continuous MLSS, DO, and turbidity measurements to an Ovivo SCADA system and alarm telemetry to field staff. Below please see a picture of one of the HMI screens for the specific unit installed in Texas. � `LL; y' y • O'OOOOL, L. • A list of the individual facilities (with NPDES permit#s) being rehabilitated with design capacities of each. Aqua NC had originally planned to complete rehabilitation for approximately 10 WWTPs using a temporary MBR WWTP. However, based on our recent experience with a rapid submergence coating, a combination of storage and "pump and haul"is expected to be more cost-effective for the smaller WWTPs. The revised list is below: WWTP 12 month Rolling Average Flow(gpd) Design Flow(gpd) Tradewinds 15,780 50,000 Briarwood (RRO) 20,575 50,000 Willowbrook 12,071 48,000 Aqua NC may use this system on WWTP rehabilitation projects in the future for other WWTPs with prior notice to DWR. • Timeframe for the work itself(from x month to y month). The work will be scheduled to be completed in less than two months for the actual cleaning, surface preparation, and coating; however, it is expected that the alternative treatment MBR may be on- site for up to six months during commissioning, operation, and decommissioning. • Construction sequence of events starting with installation of the temporary MBR plant to eventual removal off the site (with a detailed schedule- days/weeks). Sequence of Commissioning Events Approximate Timeframe Contractor prepares pad for mobile 5 days WWTP, and accepts delivery to site. Contractor provides electrical 2 days connection for mobile WWTP and genset with ATS. Contractor installs bypass pumping 5 days connections and any requisite equalization and disinfection facilities. Contractor/Aqua NC starts mobile 21 days WWTP with seed sludge from existing WWTP and partial split flow. After mobile WWTP stable operation is confirmed, 100% MLSS transferred to mobile WWTP and 100% flow. Existing WWTP is cleaned of all settled 60 days materials, metal blasted/repaired, and coated per direction of Aqua NC SME_ _Coating tested by Aqua NC SME. 1 day WWTP is seeded with seed sludge from 21 days MBR and partial split flow. After existing WWTP stable operation is confirmed, 100% flow returned to existing WWTP Mobile WWTP is cleaned and 14 days transported to next rehab WWTP or to storage pending next job. As this process is approximately six months in length and as recoating is difficult in winter, it is expected that one to two facilities each summer may be completed using the MBR alternative. • Operations and Maintenance Plan. The facilities will be visited daily on weekdays by a certified operator and operation verified. Continuously the facility will be monitored for critical parameters, including but not limited to MLSS, DO, and turbidity. If alarm levels are triggered the information will be transferred via Aqua NC's SCADA dispatch system to the field staff and management. • Monitoring and Quality Assurance/Quality Control Plan. As stated above, the system will be continuously monitored for critical parameters. All effluent monitoring will be completed in accordance with the facility's permit. • An emergency plan in the event of inclement weather conditions (high flow events), or if the effluent quality does not meet the limits set forth in NPDES permits. These facilities are not very large, and if needed temporary pump and haul will be utilized until the emergency condition has been resolved. Please recognize that Aqua NC is proactively working to fully maintain these wastewater treatment plants and appreciates DWR understanding that a wastewater treatment plant designed to meet higher quality standards than the wastewater treatment plant being rehabilitated is environmentally conservative. If you have any questions, please feel free to contact me at (919)653-6964. Sincerely, A p, pe cr,v) Joseph Pearce PE CFM Director of Operations Aqua North Carolina, Inc. 311 RLOX 121 ." / 34 L0Y1Y0iTT144t411! 1 _'I. t f OVIVO �,ty 11.44 microBLOX® MBR System TECHNICAL PROPOSAL #030921-1-MCS-R0 LOCATION: AQUA AMERICA, NORTH CAROLINA PREPARED FOR: JOE PEARCE P.E. CFM DIRECTOR OF OPERATIONS AQUA NORTH CAROLINA, INC. CARY, NC DATE PREPARED: 05/11/2021 VALID UNTIL: OvivO N/A PREPARED BY: Worldwide Experts in Water Treatment ©Copyright 2020 Ovivo.All rights reserved. Ovivo USA, LLC. This document is confidential and shall not be ? MBR Systems reproduced or distributed without prior written approval of Ovivo. The data and information 2300 Greenhill Drive. #100, Round Rock TX 78664 provided is furnished on a restricted basis and is not to be used in any way detrimental to the interests of Ovivo 515.834.6000 www.ovivowater.com I www.mbrcentral.com SUMMARY For smaller flows, true Ready-to-Operate systems are available. These systems are delivered to the site factory assembled with little or no interconnecting piping or ancillary equipment to install. Branded as microBLOX®, the facility design and layout of an Ovivo® microBLOX MBR system is intended to provide low constructed cost, low O&M, process stability, flexible design, simplified piping, operational ease and requires less automation. The biggest advantage to end-users, however, may ultimately be reduced installation costs. Contractor estimates indicate that single-stage systems may cost as much as 25-50% less to construct due to the Ready-to- Operate design, reduced footprint, reduced concrete and overall process simplicity. This proposal will demonstrate technology advancements, lessons learned and innovations that are continually assessed and implemented in-order to provide maximum uptime. One size does NOT fit all. Each BLOX® solution should be unique and tailored to the specific application through the use of modular subsystem blocks. de, #4,\. • Respectfully submitted, Martin Swanson Monte Ridenhour National Slaes Manager, MBR Systems Ovivo MBR Representative Ovivo USA, LLC EW2 Environmental, Inc. 512.652.5805 704.576.6637 martin.swanson@ovivowater.com mridenhour@ew2.net Enclosure ©Copyright 2020 Ovivo.All rights reserved. This document is confidential and shall not be reproduced or distributed without prior written approval of Ovivo. The data and information provided is furnished on a restricted basis and is not to be used in any way detrimental to the interests of Ovivo INFLUENT FLOW DATA Ovivo's design values are summarized in the Table 2 below. TABLE 2—INFLUENT FLOW DATA Parameter Flow MinTemp Event Duration Annual Average Flow(AAF) 0.050 MGD1 10° Cl Annual Average Maximum Day Flow (MDF)2 0.065 MGD1 10° Ct 30 consecutive days Peak Day Flow (PDF) 0.130 MGD1.2 10° Cl 24 hours non-consecutive Peak Hour Flow (PHF) 0.130 MGD1,2 10° Cl 2 hours non-consecutive, during PDF Notes: 1. Values assumed by Ovivo,to be verified by Consulting Engineer. 2. MDF conditions are central to both biological and hydraulic designs 3. Peak Values assumed to occur during MMF,to be verified by Consulting Engineer INFLUENT / EFFLUENT CHARACTERISTICS Influent wastewater flows or loads are summarized in Table 3 below. In the event that the influent exceeds the specifications used in engineering this proposal, or the source of influent changes, the ability of the treatment system to produce the designed treated water quality and/or quantity may be impaired. Ovivo will provide guidance to overcome characteristic variations, however, if the Owner chooses to continue to operate the system, they assume the risk or any additional costs associated with biological upset, increased consumable use or membrane damage. TABLE 3—INFLUENT FLOW DATA Parameter Influent Effluent Remarks BOD 250 mg/L' < 5 mg/L1 TSS 250 mg/Li < 5 mg/L' TKN 45 mg/L1 -- NH3 32 mg/L1 < 4.0 mg/L1 TN 45 mg/L1 -- TP 8 mg/L1 -- Fecal Coliform -- < 2.2 CFU' With Optional Disinfection Alkalinity 300 mg/L -- Coarse Suspended Solids (CSS) < 200 mg/L3 Maximum limit in MBR basins Screen Capture Efficiencies 90% Maximum Temperature 25° C Elevation 500 ft1 Notes: 1 Values assumed by Ovivo.to be verified by Consulting Engineer. 2 Particles having a specific gravity> 1.6 and unable to pass through a 65-meshc(0.21 mm)screen. 3 May be accomplished with a rescreen if headworks is insufficient. ©Copyright 2020 Ovivo.All rights reserved. This document is confidential and shall not be reproduced or distributed without prior written approval of Ovivo. The data and information provided is furnished on a restricted basis and is not to be used in any way detrimental to the interests of Ovivo SYSTEM CONFIGURATION Each microBLOX®solution is unique and tailored to the specific application through the use of modular subsystem blocks. Technology advancements, lessons learned and innovations that are continually assessed and implemented in-order to provide maximum uptime. The following Tables 4, 5 & 6 and Figures 1 & 2 provide specific configuration and specifications for your application. TABLE 4—SYSTEM DESIGN Parameter Descri s tion =Volume S stem Selection Model 4Z microBLOX® -- Configuration Design Zone 1 MBR SiC Membrane Four(4) M6 3,775 gallons Zone 2 MBR SiC Membrane Four(4) M6 3,775 gallons Zone 3 PA Fine Bubble Aerostrip 3,990 gallons Zone 4 Anoxic Mixer -- 3,370 gallons Parameter Value Units Comment Process Design Total AOR 210 lbs. 02/day 65,000 gpd AOR Supplied by MBR Scour 125 lbs. 02/day AOR Supplied By Supplemental 02 85 lbs. 02/day MBR MLSS 17,677 mg/L SRT 20 days Total Membrane Surface Area 3,120 ft2 FIGURE 1 —TYPICAL EQUIPMENT LOCATION Access Stairs I Blowers I Auto MC I Access Platform (Grating or Covers) I Chem Dose I Coarse& Fine Screens /rlil T-_ IN ing \), —11 , -co .+ I�r -- - I��r1� .. .In aIii�l \111.71-11111�' _ IIN I II III I I 1 _- 1 iii ..2 IC Sr 11 = 1 = I EC /1/A0, 11 1 A1 - al. ..; fog i \ I\ le 1\ PLC, MCP, HMI, SCADA I UV I Permeate Pump I RAS Pump I Membranes I Fine Bubble I Mixer I WAS Pump ®Copyright 2020 Ovivo.All rights reserved. This document is confidential and shall not be reproduced or distributed without prior written approval of Ovivo. The data and information provided is furnished on a restricted basis and is not to be used in any way detrimental to the interests of Ovivo TABLE 5 SPECIFICATIONS Parameter Value Comment Site Re•uirements Power 480VAC/3PH/60Hz Service Amps 200 Connectivity 5G Cellular Ambient Temp 33°F to 103°F Climate control required outside of temperatures listed. Minimum Temp 20°F w/Optional Heat Trace Water Service 40 gpm @ 40 psi Elevation 500' Assumed S -u R. •r•s Area Classification NFPA C1 D1 & C1D2 Headworks C1D1 'System C1D2 Envelope Seismic Rating Category D SIF:1.5, Occupancy Cat: II, US Steel American Iron & Steel Act Tanks are AIS compliant,with American Steel documentation Applicable to design, manufacturing, Quality Standard ISO 9001:2015 supply, installation&servicing of WWTP& WTP, associated equipment&systems. NSF NSF/ANSI Membrane Plate Panel Electrical UL Maximum Deflection %" Max deflection on any single member Weldin ANSI/AWWA D100-05 All welds are continuous seam welded. microBLOX® Footprint 45' I x 8.2'w x 12' h Sup Tank Footprint N/A Supplemental tank not required System Footprint 50' I x 19'w x 12' Includes stairs& service clearance Ceiling Clearance 7.5' Minimum clearance Service Clearance 4' Distance from system microBLOX®Weight(Dry) 50,000 lbs. microBLOX®Weight(Wet) 192,000 lbs Sup Tank Weight(Dry) N/A Supplemental tank not required Sup Tank Weight(Wet) N/A Supplemental tank not required FIGURE 2—TYPICAL PLAN VIEW 50' 4 ► •4Z microBLOX t r rTi; r I ip.. .ftC7 l Li ++j = 8.5' n.ii p f�.1' .1 i [0*r—� ,I _ :. IIi rrw` 12 e © • Copyright 2020 Ovivo.All rights reserved. This document is confidential and shall not be reproduced or distributed without prior written approval of Ovivo. The data and information provided is furnished on a restricted basis and is not to be used in any way detrimental to the interests of Ovivo TABLE 6-BUILD SHEET 4Z V1 H2 D4 D4 PA AX B3 T3 P2 U3 S1 MC W1 00 -- Base Su.elemental Tank 3Z Three(3)Zone 00 None 4Z Four(4)Zone EQ Equalization XL XL WA Sludge Storage Volta.e FB Aeration V1 480VAC/3PH/60Hz AX Anoxic V2 208VAC/3PH/60Hz i SW Swine Headworks WAS Pum. H1 Single Coarse,Dual Fine Screen W1 Sin.le WAS Pum• H2 Sin•le Coarse,Triple Fine Screen j Maintenance Clean Zone 1 MC Full Automated D1 Single Membrane Ox .en Delive D2 Dual Membranes ' SO None • D3 Triple Membranes S1 Fine Bubble D4 Quad Membranes S2 02+Reactor Zone 2 UV Disinfection D1 Single Membrane UO None D2 Dual Membranes U1 Single Ultraviolet D3 Triple Membranes (OPTIONAL) U2 Dual Ultraviolet D4 Quad Membranes U3 Triple Ultraviolet Zone 3 U4 Quad Ultraviolet 00 None U5 Quint Ultraviolet PA Aeration i U6 Six Ultraviolet AX Anoxic Permeate Collection SW Swing P2 Dual Permeate Pum.s WA Sludge Storage Transfer Pum es EQ E.ualization T1 Single Transfer Pump Zone 4 T2 Dual Transfer Pump 00 None T3 Triple Transfer Pum. PA Aeration Blowers AX Anoxic B1 Single Blower SW Swing B2 Dual Blower WA Sludge Storage B3 Triple Blower EQ Equalization Anal tics O•tions Yes-1 No-2 Dissolved Oxygen Yes-1 No-2 Cover&Rails Yes-1 No-2 Turbidity Yes-1 No-2 Grate&Rails Yes-1 No-2 Total Suspended Solids I Yes-1 No-2 Heat Tracing Yes-1 No-2 Water .-rV' Yes-1 No-2 Porch Lights Chemical Addition S stem I Yes-1 No-2 Cony Outlets Yes-1 No-2 Carbon Yes-1 No-2 Disconnects Yes-1 No-2 Flux Enhancer I Yes-1 No-2 Stairs Yes-1 No-2 Phosphorus Reduction Colors Yes-1 No-2 .H Ad ustment G Grey(standard) Adders D Desert EQ&PA Blower F Forest B Beach A 2 2 2 1 1 1 1 1 2 1 2 1 1 1 1 G ©Copyright 2020 Ovivo.All rights reserved. This document is confidential and shall not be reproduced or distributed without prior written approval of Ovivo. The data and information provided is furnished on a restricted basis and is not to be used in any 6 way detrimental to the interests of Ovivo MAJOR EQUIPMENT LIST Table 7 below lists the major equipment and instruments provided. TABLE 7— EQUIPMENT LIST Equipment Type Manufacturer I Model Dut Stdb Desigea alue HP Control TDH Rotatin• E•ui•ment Permeate(B/W) Pump Rotary Lobe Vogelsang 111112-114 1 1 50 to 113 gpm 7.5 VFD 10 psi RAS Pump Rotary Lobe Vogelsang 111112-114 3 0' 61 to 111 gpm 7.5 VFD 10 psi WAS/Rescreen Pump Rotary Lobe Vogelsang I VX100-45Q 1 0 7 to 54 gpm 5 VFD 15 psi Mixer Submersible Wilo I TR 36 8/8 1 1 N/A 1.75 PLC N/A Air Scour Blower Regen FPZ I SCL K10-TD 2 1 70 to 90 scfm 25 VFD 4.5 psi PA Blower Regen FPZ I SCL KO7R-MD 1 0 53 to 129 scfm 7.5 VFD 5.5 psi Carbon Addition Peristaltic B/W I A-100NF 1 0 0.16 gpm N/A PLC N/A Chlorine Pump(MC) Peristaltic B/W I FLEX-PRO A2 1 0 0.3 to 1.3 gpm N/A PLC N/A Acid Purr!. MC Peristaltic B/W FLEX-PRO A2 1 0 0.2 ••m N/A PLC N/A Instruments Pressure Transmitter Diaphragm E+H I T PMC131 1 0 -15 to 15 psi N/A PLC N/A Gauge Compound McDaniel I 2.5" 6 0 -15 to 0 psi N/A N/A N/A Gauge Pressure McDaniel I 2.5" 6 0 0 to 30 psi N/A N/A N/A Level Switches Float Conery 12900 6 0 N/A N/A PLC N/A Level Transmitter Hydrostatic Blue Ribbon I Birdcage 2 0 10 psi(23.1') N/A PLC N/A Permeate Flow Meter Elec-magnetic Hach I W400 1 0 Reversible N/A PLC N/A Turbidity Meter Optical Hach I TU5300 1 0 0 to 700 NTU N/A PLC N/A Air Scour Flow Meter Thermal Mass Sierra 1780S 1 0 0 to 150 scfm N/A PLC N/A DO Measurement LDO Hach I Model 2 1 0 0 to 20 mg/L N/A PLC N/A TSS Immersion Hach Solitax sc 1 0 .001 m./L-50 •/L N/A N/A N/A Other Coarse Screen 5 mm pert Envirocare I CT150 1 0 150 gpm .33 PLC N/A Fine Screen 2 mm Perf Envirocare I CT150 3 01 50 gpm(max) .33 PLC N/A Fine Bubble Diffuser Flat Panel Aerostrip I Type Q 23 0 53 to 129 scfm N/A N/A N/A Membrane Silicon Carbide Ovivo I M6 81 02 20.8 gfd3 N/A N/A N/A Disinfection UV D434 3 0' 73 gpm N/A N/A N/A Control Panel PLC. HMI. Ovivo 1 0 240 VAC N/A N/A N/A SCADA. MCP Permeate Storage BW/MC Tank 6.5'x 3.5'x 4.5' 1 0 520 gallons N/A N/A N/A Notes. 1) With 1 duty unit offline.the remaining 2 units can provide MDF for 48 hours. 2) With 1 membrane train offline the remaining train can hydraulically treat MDF flow for 48 hours. 3) MDF. ENCLOSURES The following enclosed documents are provided to further support Ovivo's supply of goods and services. • BioWin Summary • PFD • Layout Drawings • PIDs ©Copyright 2020 Ovivo.All rights reserved. This document is confidential and shall not be reproduced or distributed alig without prior written approval of Ovivo. The data and information provided is furnished on a restricted basis and is not to be used in any way detrimental to the interests of Ovivo BioWin Summary Characteristics Unit Value Comment Influent T.BOD mg/L 250 TSS mg/L 250 T.P mg/L 8 TKN mg/L 45 Ammonia N mg/L 32 pH mg/L 7.3 Alkalinity mg/L 300 Temperature °C 10 Recycle 0 6.37 SRT days 20 Total AOR Ib/da 210.2 Chemical Addition Micro C gpd 0 Alum gpd 0 Caustic ••d 0 Process Basins MLSS PAX mg/L 15,278 MLSS PA mg/L 15,514 DO PA mg/L 2.0 OUR PA mg/L/hr 97 OTR PA lb/hr 3.56 lb/day 85.4 SOTE PA % 20.1 Diffuser Type — Fine Bubble Al•ha -- 0.495 MBR MLSS mg/L 17,677 Scour Air Total scfm 360 DO mg/L 2.44 OUR mg/L/hr 84.1 OTR lb/hr 5.20 lb/day 124.8 SOTE % 4.1% Alpha -- 0.544846671 Diffuser T •e -- Coarse Bubble WAS Volume gpd 757 Mass lb/d 111.6 Effluent(Model) T.BOD mg/L 0.89 TSS mg/L 0 F.TKN mg/L 1.85 Nitrate N mg/L 6.25 Nitrite N mg/L 0.11 TN mg/L 8.22 Ammonia N mg/L 0.39 TP m•/L 4.8 Effluent RFP Requirement BOD mg/L <5 TSS mg/L <5 TN mg/L - NH3 mg/L <4 TP mg/L - ©2021 Copyright Ovivo.All Rights Reserved Page 1 of 1 BLEACH (BY OTHERS) _pi BAD(M91/CP TANK CARBON ACID (BY OTTERS) (BY OTHERS) mivaBLOK 901)LMT _ gam-- —I _pi..--P-1► D . OP DACE PUP DOSE PUP (ACID) (CARBON) ��\) I v L {�L� 3L� CP DOSE PUMP PA BLOWER PA/�/�WAVIA\/IIBR N GLOVER /(BBR�BLANERJ(J\ I (DUTY) STNID-BY (WTY) (PITY) MR EXIRACRON BYPASS I BLOWER r-- Mel • L—- I ,O° \/J OVERFLOW TANK I , PLANT ) 17 I a a IN .4 -I WOW II A , $ A Lp 'Ip �- RAS T bS S� ZCNE 3 PA-01 -► ZONE 1 lie--DI I • I gr �, I T T T (PRE-AERAIEGI BA9N 02) 181 mew DI)Op - I . I yl��. UV UV UV 1 I ► - r 2(X\' I (ANO%IC BASH m) I I I I I I I I -� MR 2 IN-OZ _ 1 R BASH oz) J I �- (R/) I PERLEAIE�SACKWASH T T T TANK DRAIN + IF • • I (Z Wm (BY OTHERS) ,-,.. L , MI icAl- CR I . IV'wAs/RESCREEN I PUMP FED)FORWARD PUMPS ——— (3 DIM ' WAS L I • DISPOSAL I (BY OTHERS) I- I- RI I ED/WAS BLOWER I (DDm E0.111-4.WAS THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVNO,AND ITS O\Y/I�Y/O AFFIUATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS OF OVNO OR INSTAWNG,OPERATING OR MAINTAINING OVNO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment AUTHORIZED IN WRING BY OVIVO. UNCONTROLLED COPY IF PRINTED- microBLOXo �)MILLI I°1 pia 1`c`K°1=" DO NOT SCALE PRINTS MG SCALE KW °m,° INITIAL RELEASE / // / ccorr-om am wno C1 P F D WORKMANSHIP SUNDIRD E50001 APPLIES :�� S o REVISION EN BY ours DATE ALL"OnI USDD-ACV 1 A ITEM CITY DESCRIPTION MATERIAL PART NUMBER TOTAL WEIGHT 1 ASSEMBLY,MB,V3,65KGPD,TANK,SHIPPED V365K GPD-1-300 45365.975 2 ASSYµUM CHANNEL FOR COVER MOUNT,V3 234618 289.135 3 ASSEMBLY,MB-V3,TANK TOP HANDRAIL 234646 559.605 4 ASSEMBLY,MB STAIRS W LANDING 230659 821A34 ``8 S ASSEMBLY,MB STAIRS W LANDING 234660 929.319 6 ASSEMBLY,WAS/DRAIN,PIPE.BY OTHERS 6Y OTHERS 55.645 0 i 7 LIFT LUGS WITH FASTENERS 234-185 213.310 `f8 %\ 8 ASSEMBLY,MB,CIP TANKCN UNITS 234-521 481.337 ii :iri %,,.. . ,„, ,iii 4 _:., .1;4 (4,0 - ,. .1 41%411444.--- '''''''......"\ 1%4. 11I %1li 1� IL.. I\ \ I �f 1/ . 1• ••Ik 1\ . '.. 11# \ Al.• ok . '. - 11,,:ip ISHA ik\ .'• .. .�� '=jiW\' .-1,4;k\Ak L' , ,/N.4.7,‘)* \� III\ \11\.k.,/lk,,04.„ , P. ilitlitlAti*if":7,..:1-4,..::A:1-\'1.i ,, ',"-.• 7-..--.1 =--- / ,, ._ 1‘.... BY OTHERS ;L�.I I II', f / /I/ I 1.:j1�� o ly\ !!.,.,. . ,-.'">;.--ire.-w4.. ...4_ 11. r '''*1,...,.: ',_.,9) '1*".i,, 1 d AI,' •II MATERIAL e`,/ ID It SALES Wank GP0.01 �1 �/! QUANTITY • 1�, SEE BOM /I fr. �/ FINISH SEE BOM • /I ft/'I,q/ COST CLASS fr / BEmu �I _ OVIVO NOT FOR CONSTRUCTION ':'" " ••• = *FINAL DESIGN MAY VARY* REF.FRO.1 •. .DONOT�P rlwv3►slcaroosrAurmn wIE.w.�I W1172019 d.+. DRAWN RD 1 DV MGM."' 1R M-V3 65K 15H / A C IF— B - - -i Y � I � I A ** III ;I: likk A !k 4 A"INFLUENT I'I�:I: Mil O. � . !�= Mkr0g4 LON trjf --Ak* 71 "lair.?4wt. ....iiiri li -"gra—, —. I w I .r,. r.. f II 6`OVERFLOW . r �m :Il IIIIII1Lw' Milli - ,— �'. Witi %Ns (��,fri.El a��_Kr'L�' ' 1 —dr,: _ !.,71,p, .!,7! .. ,1,..:11..11_, - : 117" : ,,,,,,, 1111,111vs'.°:"Iii NI114114,11, Pi % VIM 1 :s 1.74.16 ri ; o Q .t—.,1 • imiaimi Imi , • --- ri, 4:.. :el .;,i. a II"N ='-If1VIttt s,1111 1 ; — A- -- B _.-6u.• 0 I \ C( I C 3,4 7/I6 ,I.'PERMEATE TIE POINT 2'3o Ua. 1'-3 3/!• NOT FOR CONSTRUCTION *FINAL DESIGN MAY VARY* o OVIVO ...mon.maaunw®new w.wws ioielsm..w Ylri.y..FAY.1••••• D ®ca 1.N'T StAll" Rio M-V365K a i 1 49 Il � .� ` , _ - (CEO) -',1{cal:Illa MOT T II 1111, I111: .11? I. IU _ 1 ;l 1.1 } •ILII •ILII •ILII 14 = _ ° 1111111iI _ °ii sisal. m�u 101111 (ELI) 'I � `11 } I '� EII I[II I[II owl °° 0' Ifi�:,il ns IIIIIII .. .. .. .. .. .. 3 III .�• ♦��. - a WRIA) 'II CS:ii °; lit I . n 6 i1 .. —.i.ii.. iu:i.. _ n _nI i.tl1j -'C 3i7-■.: 11' ® I 6 6 r- limn, r9 it'l frl / _ '..--' . l.' /vj vl v I 0in o • 8 t / 17A 3/6' 3'-73/16' VIEW A-A jGRATING TURNED OFF FOR CLARITY) NOT FOR CONSTRUCTION o OVIVO *FINAL DESIGN MAY VARY* �� .._. 0p 00N°scm" 1 M-V365K rr, 1 .,-F8 % / , .: . i. f'E.! !rt1 - I I :I: s Il lill K B. r R� 4 .• r . : !I I Oily. 110 \\ r 1III� 1�'` I I L •. \ II I- Iiit..-4.1-: ;;itlititii.i. . `'_ II _I; .l j i �`, .1 / L_W 1 1 ,,,-..., .':r.F.i: •— ill s`_.;i,l i / d t 10-- I I� 0 s 2'WA TIE © 0 �,J (BY OTHERS) VIEW C-C VIEW B-B NOT FOR CONSTRUCTION a ovuvo *FINAL DESIGN MAY VARY* 8". o°`""`"°" = ===. ....M-V365..r.... .� U ®o Dm. No.' M-V3 65K :77, p " wil ,.., _ IC\ i j•-).', , f!"! -111 Er _j - - _ - -. m 1ULOX II�'I'I. i il� rt E* Cr .L 1r�11I!,. It . .,. ' - • ,rj _i_-71, j;4i IF.444 ill 271w:—4,..,:i.. 1 '-- i'.11 • 77:-iEd .:1111;—, .. 1(-= : I -Olik AA !i VIEW D-D z \ NOT FOR CONSTRUCTION _ OVIVO *FINAL DESIGN MAY VARY* o_ 100 00��%r• M-V365K rar, �" A © •/•,. . mb. .. /,/ -ItiZ,i.,,W., --.. 4 24'.1:11.':a04*•,.114.fity.....1111S•Ni ,...,,„-Ar,w,.e.4.,",.oilti,..,71 04 **'.. 4' ‘ 41,,-:iiiii.--4.:+re,41 _ - . 6..1 1,'119* 4.i '41111 .1i,■.tea :` ':1> z, t 0 _Ii, •10 igi 'lAt o I • . Imo... ..II 7' �: ..4.0 * /II L„,„ir. ► -4 ; ;-' I se, .__. ___ „-.--I• i , •:" \ __, 0(0,..r,,,, 441.;,t, it ,t;, i.:� . ail j' � `�;�i 1* .' 1 eii:0 al ; o NOT FOR CONSTRUCTION \ *FINAL DESIGN MAY VARY* �.---MID MaIIII -.OIR•-- p ®o 0orarsr.L.r�enswti M-V3656 sties. ^� -.ram �....e.�,..r xo. t oFa p OVIVO Worldwide Experts in Water Treatment 2300, Greenhill Drive, #100, Round Rock, Austin, TX 78664 phone: (512) 834-6000 I fax: (512) 834-6039 microBLOXTM AQUA AMERICA WWTP Sheet Index I-1.1 LIFT STATION&EQUALIZATION TANK I-1.2 FINE SCREENS I-1.3 PROCFSS TANKS&CLEANING I-1.4 FEED FORWARD PUMPS 1-1.5 PERMEATE CONTROL AND DISINFECTION I-1.6 MAINTENANCE CLEAN/BACKWASH TANK I-1.7 MBR BLOWERS AND PRE AERATION BLOWER I-1.8 WAS PUMPS I-1.9 CHEMICAL DOSING 1-1.11 SLUDGE HOLDING TANK 1-1.12 CODES LEGEND I-1.13 SYMBOL LEGEND THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS �\/'�O AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS Y OF OVNO OR INSTAWNG,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment A AUTHORQED IN WRmNG BY OVNO. UNCONTROLLED COPY IF PRINTED AQUA AMERICA n""' la"t'c.taE"°1" DO NOT SCALE PRINTS mimeo* re. DWG SCALE INITIAL RELEASE OCOPTIMOHT m10 Dodo RORK111115LV STANDIRD ES0001 APPLES waE urreEi-]..� r 12 REVISION EN BY men DATE /// ALL"'KIS��m-REV A COVER SNNt T pp TYPICAL FOR 2 pp TYPICAL FOR 2 aa a � aa i3 4 3 ° a a 8 'Ai a � PLC 1 I 1 PLC -I --�-I - +- - — L — — — 1— —I - 1 1 1- - - - 1 I �J I 1 1 I 1 1 1� W} MCC I 1 I I I I MCC - - - - 1 - - -I - - --I - «- - - - *- - - - - - - r 1 i r r I r I r r El r14421141;i.4"Ualli"': 111 _ T- 1- 1 r -4 BY OTHERS I ee ee 77 C ,-.c-L� A coA T'sc EEER') L, I "Ray oTHERs�1 OAT > E I.-. )rev i` (BY ORERS) WEG-LS1 4 5 g " --- 6 El 1 1 1 t a $ � l l 1/4 • • 1 1 1 . , EEIl AED z _ Am CB-E01 v ®CB-Ev 02 fE fl LE-230103 P P 230101 PIIP »2 1E-020103 P EE 01 P �02 LSLS01 EQ_O1 UFT STAIN TRAv1 TRAP EOUAUZATION TAM( 1Nc-230100 DM-0201m THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO NQ1FS: AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS UNLESS ODIERWSE NOTED,ALL PIPE,FITTINGS,ASSOCIATED HARDWARE. OF OVIVO OR INSTALLING,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment VALETS,NSIRIAIE/IIS AND EQUIPMENT ARE SUPPLED BY OMM1 AUTHORIZED IN WRITING BY OVIVO. UNCONTROLLED SUPPLIED BY OTHERS UNCONTROLLED COPY IF PRINTED AQUA AMERICA GTE l.5 laI lP.!CHEM I u SGLE NO D E OPTIONAL ITEM BM 10 DO NOT SCALE PRINTS m:,o. �� Ea " All RIG119OCOVYRpRgIE0-ESA � �paO�, pSTANDARDsB�Ro ESOooI APPLES LIFTSTATION fi EQUALIZATION TANK s"EE' I-1.1 of 12 TYPICAL FOR 3 a 5 Ir(Y)1 ( 1'''5'- < 1•2 g<VI > < -1 '( ''' ;12 K1A2 6-4 g ' ' ' ' 68 1;1 a ; PLC I 1 I I 1 I I — - — PLC - - I I I I 1 IWIR RAq p-I-- IIIMI BIIMII lI 1 p_1__4 MCC — +-1— --r — MCC —� — — — — - — — T — 1 1 I I I 1 L- J I(I I I REMOTE VPN I AUTODIALER , I I I I I7• FS-0102 AUTO AUTO � CS-olol RRR J FS-0103 WAS RE-SCREENIN �•� • ; �' P FROM F WAS-1 MP� ( Y-h4K oa )— —�/— L] V-Ol O1 D7 ,/ REF SNT -1 B // CNV-010101 Mr FS-0104 • RAF"sH(BY OTMERS I-iJ t (BY a cHv-010102 v-010102 v-01m03 v-Dlolas 6 w• C$-01 P FOR 3 COARSE SCREEN 8 ' .I II o CS-OIO1 II 5 V-010108 .. ] ` SCREENED Dal r nc.n,-Ica > — B To Axl Sr mm a V-010109 (B•MMIW16) f�F SHT 1-1,3 01, :1 ail' FS-C1 SNPM (BY OTHERS) D : Svc— WC WC:3.1D4 310100131441 FINE SCREEN alb:033 hp ia/Silo FS-0101ResR :130I3W GV FINE SCREEN DIy :3(2D+IS) Type :2 met Screw Screen MBC :301 Stai4w Slid Drb:0.13 AP I130/3/8O Flow :50 GPM THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS O7♦ 11 • O NOTES: AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS UNLESS OTHERWISE NOTED,ALL PIPE.FITTINGS,ASSOCIATED HARDWARE. OF OVIVO OR INSTAW NG,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment VALVES,INSTRUMENTS AND EQUIPMENT ARE SIPPEED BY MO. AUTHORIZED IN WRITING BY OVIVO. UNCONTROLLED COPY IF PRINTED AQUA AMERICA OATS I lost tart m E SUPPLED IT OTHERS. DO NOT SCALE PRINTS m•,oe1O%® OWL SUJI,,MFR �,1 aI OPTI NA ITEM NOB x ®ui 1.o. CCOPYRloNr 2010 OVIVO I-1.2 a1 12 Au RIGNIS RESERVED-REV A / NORKWIDFIP STANDARD 60001 APPLES FINE SCREENS v�EET >p s i 1 ! ,1 # E 1 Ili I ''; ' ' lel ) I( ' 1 I I PLC 6 (" tr,,,.., .0 0.2 im ;•-;{: PLC - - - - • -i - I I- - - - - +- - - - - + - ; -I- 1 - - I I I i I MCC • - - - - -. - - - /- - - I- - - - - -r - MCC k l r J r Fi �""'7: i i tea pRY�TD ppy pL�pS\ f;1.��7RRR!!' ,,< Y-P6-nrr-ace fic�Rrt-70+ C B/N REF�PTRMTI PSINPS > V-070209 / I� HIGHEST POINT © :•,,,",r;•J ' ON HEADER L, �{ An Ice L9. AIR EXTRACTION SYSTEM ppRR�pr��SS ® � BBr L 10REF�TAIAP >--( Y-Io11S-A-P T }--- --y- e ® e 4. Y-INC -7m )v-o�iola9 - - 13 I m m I /4 1/ T-o7mm 4 I/O. I I V-071109 DV-07010417.+n +ron I J +, I NEG-PT3 BEG-P72RA____ �01 (BY OTHERS 1442444 )1 K - -I\I-————-,— TP Os ) REF SHT 1-1.7 V-A51 C-Pn- NEG-PT1 I ann -o7m10 cNv-o7mm 1,404 I-I\I-iI--- �— —r--0-T— T---0� —— 1---•-)--+� — — — — i _2.1 _ V-A52 M B S4Tm,a I-Z r-INC -1o9 )— I ±' 4>f> p>I I > 0 T�T i > g�> 3 I > g I e `BY OTHERS) -c- Iiyh 1 1 1 ` 1 1 I ( r-.,F,,,,,. T y■ i ,� EYE Ay �. �}, ,� (BY OTHERS) — +; C Z > I I 1 I 1 1 1 ~fr 1 ~ Z ` W M ! 4 F®FONNARD m� V-AX1 M%R-oNnoz _ _ _ _ _ r-rwn-ml )--I D N1i`% FED-050102 ` E 050-070204 0w-07 2203 05D-070202 05D-070201 1 o2D-07mla o2D-070103 DSO-070102 osu-070101 v 1 1 MBRZ 1maa �, (zoNE-a) h(zwE-oar) (zaE-o2 0702) (ZOfE-m;0701) — I I ( •'P1cwrL m �- I o ow > MEMBRANE Silicon Carbide(SIC) VVV>2'#3m #!m 0.1 #'1� VVVV1 .qm (BY OTHERS) Stack Height: M6 Nominal Pore Size: <0.1µ Surface Area Per Diffuser'fps: Coarse Bubble -rlc rs- E RWFWP M1 S0 \ GlosEILDX S)wn-9C Me 094 THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO NOTES: AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS MESS OTHERWISE NOTED.ALL PPE.MTMNOS,ASSCOATED HARDWARE. OF OVIVO OR INSTALUNG,OPERATING OR MAINTAINING()VIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment VALVE,N15IRUYENTS AND EGUPIIENT ARE SUMO BY 0M10. AUTHORIZED IN WRITING BY OVNO. PRINTEDUNCONTROLLED COPY IF PRIED I)SUPPLED BYor.n 1 ova. 1.1..Ic,.<.,( mots. AMERICA .. a)OPTIONAL ITEM 8 rl Cli DO NOT SCALE PRINTS .,roBLO%° DWG KALE roar m,a. ALL RESERVED REV A �J WORKMANSHP STANDARD 60001 APPLIES PROCESS TANKS AND CLEANING B"BB, I-1.3 a. 12 TYPICAL FOR 3 o 8 $ 1 3# ias as a PLC 1 1 PLC — — — — — — L —I — — — — — — — — — — I I I I 1 MCC — — — — — — — — — — — — — — — — — — — — — MCC D 'Rau v lf° / r( -wfi C -,°, > O O C r r c rr-a F 11r I'A REF SHT 1-1 3 REF SMT 1-1.3 eTh ° V-�01 CHV-210101 V-210102 ie PUP-210101 PUMP PACKAGE ^ 1. 1. Feed Forward Pumps(Vogelsang 10112-114) z�O Qty : 3(30) v v Min Rotary imum Flow Rote : 61gpr1l�e D Dca ✓I p20__,:c-- Mosimum Floe Rote : 111 gpm M V-210201 ^ CHV-210201 V-210202 A/ Mo:mum Disch.Pressure: 10 psig Motor Sze : 7.5 HP PUP-210201 PUMP PACKAGE D 21I ofe M 0-210301 I. 040-210301 V-210302 HE PW-210301 PUMP PACKAGE FEED FORWARD PUMPS THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO NOTES: AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS UNLESS OTHERWISE NOTED.ALL PIPE.FITTINGS,ASSOCIATED HARDWARE. OF OVIVO OR INSTALLING,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment VALVES,INSTRUMENTS AID EOIPIRNT ARE SUPPLED BY OMVO. AUTHORIZED IN WRITING BY OVIVO. UNCONTROLLED COPY IF PRINTED I]SUPPLIED BY MOTS AQUA AMERICA °°°]°v""" la.lna]`Ha`"°(,. DWG SULE a]MON&ITEM B 1, DO NOT SCALE PRINTS m_,°aL°+® N.oaraAafar r,. Ell ALL RIPER ESERVEDED-REV A \� WORKMANSHIP STANDARD 60001 A'PUES FEED FORWARD PUMPS SHEET I-1.4 °r 12 TYPICAL FOR 2 TYPICAL FOR 2 T1PICHL FOR 2 A a - k - ,d ._ i _ k - '- c ,g ; 'A g #. g 1 g ( .____ g ;r(:).:1 > ' ' '; r--°-:- -:PLC i ' +rr9 +- - - - '- - - - - PLC - - EA ©--' - --' m I MCC - - - - - - - - - - J - - - I - - - - MCC c IDLL R R -1 6 / �I��I A� L ® YI H FR01F CP o1 > w ® 8 e > ro oR,uN AFF SIT I-1 8 ' B Tr Met fez' I I\ NI- IN=SEM 30 I row. :,F SHT I-1 3I v-Denim v V-0em0z \ r 06 N. \ \ PrP ae t XV-OB04m FE-oeo3m V-16m02 UW-temm V-180103 10o --t PUMP PACKAGE I\z I \ ED v-iBDzm UVU-18D201 w1BOzoz w nBmc1 - - - v-116\02m UVU-1B0201 Him, Permeate Permeate Pumps(Vogelsang IQ 112-114) DV: 2(1D+1S) O @I ®DISINFECTION PACKAGE Type: Rotary Lobe Minimum Flow Rate: 50 gpm I Disinfection:UV(Neotech D438-1) Maximum Flow Rate:t13 gpm I Type: Milne Maximum Discharge Pressure: 40 prig OTT: 2 Motor Size: 7.5 HP I V- 01 V-I\1- — — PMP-0032 PUMP PACKAGE PERMEATE PUMPS ,r,{,r I e e e �.�; owo e e j �1Yi sx 11 ABMc> C t.wen.AI ) El I I FE-080301 XV-160103 THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO /I\/O NOTES: AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS •V UNLESS DTHERMSE NOTED.ALL PRE,FITTNOS ASSOCIATED HARDWARE. OF OVIVO OR INSTALLING,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment VALVES,INSTRUMENTS AND EQUIPMENT ARE SUPPlID BY MD. AUTHORIZED IN WRITING BY()VIVO. II SUPPLIED BY OTHERS. AQUA COPY IF PRINTED AQUA AMERICA WE I WIW, IH+h 101EC.I b7 OPIII NAL I1EM B rt C3 DO NOT SCALE PRINTS ,H.,osioxe or H Hass �,,. ALL RR;His W ESERVEDED-REV A �l WORKMANSHIP STANDARD 60001 APPLIES PERMEATE CONTROL AND DISINFECTION 5 HttT I-1.5 0, 12 TYPICAL FOR 2 8 8 j a a a 6 a PLC PLC — — — — , — — — — — — — — — — — — — — — — — MCC MCC —I — — — — — — — —T— — — — — — — — — — — e Ir5 I_�I xi `--'I wry{TD p CSC '• PxF(e�� ff i-t G r oTHaasJ� I I BLEACH PUP-IIOTDI 20 gala, INK-140101 I iwI=ET L--J Alp Ip \ I �1 ITS H I PREfgIIE P1UM5P > I Q CSC I (BY OTHERS) ACID PUP-uozm r—'' 20 Ow INK-1�0201 WATER FM HOSE> (BY OTHERS) ee Ds mew$ AEIµo ! �' Y V-T MC/BW-160101 TO DRAIN(BY OTHERS) MAINTENANCE CLEAN(MC)/BACKWASH(BW)TANK laoo gala, THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS O• I ♦ O NOTES: AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS UNLESS ONI RNSE NOTED.ALL PIPE.FIT11N0S,ASSOWTED HARDWARE. OF OVIVO OR INSTALLING,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts IT Water Treatment MASS,INSTRUMENTS AND EOUWMENT ARE SUPPLIED BY OVM1O. AUTHORIZED IN WRITING BY OVIVO. UNCONTROLLED COPY IF PRINTED AQUA AMERICA WE I.,ESE IB.IR.IUNE�I p slre�D onrns Q .,�T „o„, 31 oPIg8AL IIEM DO NOT SCALE PRINTS mR&P&ID JOB NUMBER o>on,E,� *COMPORT 2010 OVNO �� WONKWINSHP STANDARD ES0001 APPLIES iLl PB.ID snErr I-1.6 of 12 ALL WOOS RESERVED-REV A MAINTENANCE CLEAN/BACKWASH TANK TYPICAL FOR 2 TYPICAL FOR 5 TYPICAL FOR 2 k k a a ; a i a i a 8 3 8 3 8i W # g 1 a � °a a a j › ‹;› > ; ‹;› ; ; PLC PLC I I I 1 I 1 I I /y\ 1 I _J �-/NW , O MCC I MCC — �- — — —I — — — — — — — — — — — — —I — — — — 1 rt ;1 PRV-080101 1 W1111 I ---Lam'--p\�- --I-- o ----- ice- \i -'----�-- ©■"�k�i'/s, CHV-000101 V-030101 I FE-090102 CHV-090101 V-OBOt05 :,� AIR SCOUR BLOWERS Im I I I AR SCOUR BLOWER I I Rower: g FPZ sa-K10-TD L J la I Qty:3(2D+1S) ! HS Floc 342 cfmi. Pressure•. 6.85 PSI I- we -1 I I Motor Size: 25 hp I PRV-0NR02 I I I V ---YY1I--I08-- V-I\I- I �-1 I CHV- - I Bla-OWmox AN SCOUR MINER J I PRY-090103; I IT L , i Q ---Y-I- - -----1-I\F-Iv-o9mo7 0103 I a 1 1 PA BLOWER I PRY-tootm Iw ' L tWA-OBOIo) SCOUR AIR/PA BLOWER(STAND-eV) I j i Blower:FPZ SCL-KO7R-MD T 1 I ■,,��.;��;;�� ay a I I ElPt. I Floc 95 efm --L_�- \�.i- t-slw-rA-a )--L- t-zols-rA-aw )- Pressure: 6.5 PS I CHV-100101 v-100101 Motor Size: 7.5 hp I — I L BLR-100101 PA BLOMER J EQ/WAS BLOWER n -1 1 M FD T I-1. > RFF 1.1 I Blower..FPZ SCL-KO7R-MD I PRV-110101 1W1W I Qty:1 I pCEy� Flat 95 cfm I ---1-RI---\- 1 - r-pw-,u-w1 )--—-I- I-----C r-zlwo-WO )- 1 - N PTD SHT R \> Pressure: 6.5 PS I CHV-110101 V-110101 T Ur 0t� REF SHT I-1.10/ Motor Size: 7.5 hp I I L®aLR-110101 EO/WAs BLOWER J THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS O♦ I�O NOTES AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS UNLESS OOfRWSE NOTED,ALL PIPE.nTTR000.ASECCLMED HA00WARE, OF OVIVO OR INSTAWNG,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment YAM;NSINW AN ENTS D EOUPMENT ARE SUPPLED BY OVIVO. AUTHORIZED IN WRITING BY OVIVO. UNCONTROLLED COPY IF PRINEED I tme lev(.ncx(cHEo I- OPTIONAL IN3-.)SATPUED N B %�, DO NOT SCALE PRINTS THERS AQUA AMERICA pw„SUeER „„NE m P&I D *COPYRI°MfRzSERVED-REVA HIP ST D 1 '� MBR&PRE AERATION BLOWERS s"Er' I-1.7 01 12 ALL RDHTS TYPICAL FOR 2 k 8 j a a 4 4 4 a a a a 8 a j a PLC 1 1 i E ..3 &;NEKI I --' r PLC - — — — — — — +I —I—I— — — — —� — — — — T-- — — — — — — i I 0 0 0 V.7 °"�a MCC J — — MCC e e e _, o l Pis ea we )XV-190102 REF 91i I-1 2 re,a er' e O O e- I , u1R rz m ( I 0 E W, pE,> 1.v r ns.As so ) Q wsFTm B> TB RFF I-L3 I V-190101 CNV-190101 V-19D102 FE-190104 %V-190103 Y OTHERS) PIP-190101 PUMP PACKAGE WAS PUMP WAS Pumps(Vogelsang 0100450) Qty: 1 Type: Rotary Lobe Flow Rate: 7 gpm Maximum Floe Rote: 54 gpm Maximum Discharge Pressure: 15 psig Motor Size: 7.5 HP THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO NOTES: AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS V Y UNLESS OTHERWISE NOTED,ALL PPE.FIT1WCS,ASSOCIATED HARDWARE. OF OVIVO OR INSTALUNG,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment VALVES,INSIRUYFNIS AND WHIM ARE SUPPLIED BY ONVO. AUTHORIZED IN WRITING BY OVIVO. UNCONTROLLED COPY IF PRINTED AQUA AMERICA ATE I�,0M1 IN.I�ILNECWNI" iI OPTIONAL BY OTHERS DO NOT SCALE PRINTS mmoeloN® DWG s E `°.E 3I OPTIONAL Hal 'Oe NU BI-1.8 eo v.').2 °COPYRIGHT 2010 amv CIOWIXLNMANSNP STANDARD 60001 APPLIESPAID El* ALL RIGHTS RESERVED-REV A WAS PUMPS SUM 5 8 8 8 4 6 (,, PLC — — — — — — — — — — — — — — — — — — — — — — PLC MCC _ MCC L vr' I�„I'1 �nrx F n 1 on YOW I +r: I m �s I REF�T 1-1.1 MICRO C 1000 GALLON PNP-140401 TNR-1A0101 THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO NOTES. AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS UNLESS DO[RNISE NOTED,ALL PIPE,nTIINS,ASSOCIATED HARDWARE OF OVIVO OR INSTAW NG,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE VALNS,INSIRUIRINIS AND EQUIPMENT ARE SWPI IED BY OVIVO. AUTHORIZED IN WRITING BY OVIVO. Worldwide Experts in Water Treatment WHIR 13 SUPPLED ex S. UNCONTROLLED COPY IF PRINTED AQUA AMERICA DATE L... 1101 ICeE=K°I.< al DPODNAL ITES B (4, 0 DO NOT SCALE PRINTS mr,oe�°x® ° NUMca _ ALL R rtRnr2010�av A \l '� �STIIIOBRD 1'DES CHEMICAL DOSING SW, I-1.9 °e 12 8 1 KIr PLC — — — — — — — — — — — — — —1 — — — — — — — — PLC MCC — — MCC N Pna BLONERs r -wc -1'F BY F sHTTH F1 S ER (BY onnls) O a Q wAS PUNPS C w ) ) q q BY OTHERS DISPOSN CD-wAS1 IWAS2 ® A® (Br DM ORS) SHT-01 LE-190101 sUIDOE MAIM TANK TNK-1901 m THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO NOTES. AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS UNLESS DlltN111Se NOTED,ALL PIPE,M INGQ ASSOCIATED HARDWARE, OF OVIVO OR INSTALLING,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment VALVES,INSTRUMENTS AND EWPMENT ARE SUPPLIED BY OVIVO. AUTHORIZED IN WRITING BY OVIVO. UNCONTROLLED COPY IF PRINTEDII AQUA AMERICA °""I°s"°'" I°vi�I HREOI SALITEM D or T OTHERS. B �a DO NOT SCALE PRINTS % JOB uR„EN ,,�SCALE ._„� °COPYNK?R 2010°VIVO �� WORKINNSHP STANDARD E50001 APPU6 P&I D SDEET I-1.10 of 12 ALL RIGHTS RESERVED-REV A SLUDGE HOLDING TANK TYPICAL VARIABLE LETTER COMBINATIONS EQUIPMENT/INSTRUMENT PREFIXES EQUIPMENT/INSTRUMENT PREFIXES ENITOES A/q SUOFDWIG ACP ACCESS CONTROL PANEL Ti IEMPERARRE TRANSMITTER CONTROLLERS READOUT DEICES ALARM DEICES TRANSMITTERS LETTERS SOEEMODS, AO *EROTIC SXISIER TV TELESCOPING VALVE RELAYS, NNW AE ANALYTICAL SENSOR UPS UNNTERRUPTIBLE POWER SUPPLY S { COMPUTING RAINY TEST 0(51 A DEVICE SAFETY FB4L AN ANAEROBIC OW ULTRAVIOLET UNIT FIRST INITIATING OR O N }L N * P! AIT ANALYTICAL INDICATOR TRANSMITTER V MANUAL VALVE LETTERS MEASURED VARIABLE i i DENOTES EIFIEIFT PANT PROBE GLASS DEVICE ELEMENT a A Analysis ARC NC AC - AR Al ASH A9. ASH. ART OJT AT AY PE AP All - - AZ A NAM AT ANALYTICAL TRANSMITTER VFD VARIABLE FREQUENCY DRIVE B Bamr/Combuaton BRC BC BC - BR Ell 094 BSI. B91L BR7 BIT BT BY BE - NW BC - BZ B _ HOP POST ANOXIC WE VIER C User'.Choice _ _ _ _ _ - _ - _ _ _ C CLOSED BUR BLOWER NEC NEW GATE D User's Poke _ _ _ _ _ - - - _ - _ O _ COD COARSE BUBBLE DIFFUSER YR ADJUSTABLE WEIR E Voltage FAC DC EC - FR ElESH EA ESE (DI O7 ET EY EE - - _ - a _ CFR OEMICAL FEEDER XV AUTOMATED OPEN/CLOSE VALVE F Floe Rah INC FIC FC FCV FR FT F91 FA F94 FRT NT FT FY FE FP - FO - PZ F _ CHV CHECK VALVE FQ no.OrntIty _ RAC FDIC - - FOR FP FO91 FOSE F09L - FO7 MT FOY F - _ - RIZ - _ DR CLAREIER FF Flo.Ratio F FF1C FTC - RR m FF91 FF9 FF9E - - - - - - -OE _ _ _ FEZ - _ OOP COMPACTOR IRC G User'.Chia _ _ _ _ _ - - - _ - _ O - CON CONVEYOR H Hand - IC IC - _ - - - _ - _ H LBW CNC COPACTOR/WASHER/CONVEYOR 1 Darr/Net RC BC - - M N ME 19. SIC MT IT IT IV E - - _ - IZ RR HIGH HAMDEO DE-ODIC I Poor JRC X - - aJI .9 JA NHL AT LIT LIT if E - - - - JO I DRY BN)SOLIDS DRYER K Time KRC IOC KC KWKR D A KB K91 KxL ART lOT KT KY KE - - - - K2 J _ OOCS ROCS OXYGEN GENERATOR L Lo,N LRC LLC LC ICY LA U L91 L9. MIL LET UT _LT 12 LE - IN LC - LZ K _ EDT EWCTGR TUBE ToUser'sP User's aice _ _ _ _ _ - - _ - _ _ l LOW EJ EXPANSION IONE N User's Poke _ _ _ _ _ - - - _ _ _ LL LOW LOW El) EWALIZATIW 0 Um'.Choke _ _ - _ _ - - - _ - _ M NIDE FP) FINE BUBBLE DIFFUSER P Prawn/Vacuam PRC PIE PC PCV PR PI P91 P9. P9L PRT PIT PT PY PE PP - - PSE PZ N _ MODULATING CONTROL VALVE PO Prawn DRRranOd PAC POC POE PDCV POR PO PO91 POSL POW_ POT POT POT POT POE POP - _ - POZ 0 OPEN FE FLOW SENSOR 0 QVunOY ORE DC - - A 9 091 OA 0911 AT BIT 0T OY QE - RW - - OZ P - Fl FLOW INDICATOR R Radoton WC RTC RC - RR RIR91 R9. R911. RRT MT RT RY RE - - - - RZ O _ Fli FLOW INDICATOR TRANSMITTER S _ Speed/Frequency SRC SC SC SCV 9t 9 591 S 59L SRT ST ST SY SE - - _ - SZ R - PS FS T _ Trrprotan TRC TiC IC ICY TR R L T TSH 15L 19RT TIT TT TY 1E TP TPW - ME 72 S _ FT FLOW TRANRANSMIT7ER TD Temperature DRrH MO IOC MC 10CV TOR TO TD91 RDA T091L IDRT 11XT MT 1DY TOE TOP TINE - - 11OZ T - OR S U Mdthvinb - - - - UR UI _ - - - _ - _ U - CRC GRIT CLASSIFIER V Nhratkn/Mochkry Md1W - - - - VI 'AVSR VS. NIL ART PT VT VY VE - - - - VI V _ GE LEVEL SENSOR W Weight/Force ARC MC IC ALV Nt IN INN WA 19L WRT MT WF WY WE - - - - WZ W _ UT LEVER INDICATOR TRANSMITTER WI WO Weight/FWeight/Forcer DitnH WORE tC WCWICV AOR AO WOSH NEL N)9L WORT NIT INT SOY WE - - - - WIZ - _ l91 LEVEL SWTO1 HIGH X _ UndndRed _ _ _ _ _ - - - - _ % _ L911 LEVEL SWTCH HIGH HIGH V Erant/Slot/Praana - IC YC - YR A YSH YSL NHLYRT AT YT YE YE - - - - Y2 Y _ l3 LEVEL SNATCH LOW - 2 Pooitkn/DYnrok ZRC DC ZC ICY Cl D IN EL Z9L ZRT DT ZT ZY ZE - - - - n Z _ LEVEL SWITCH LOW LOW ZD Gaoying/Deroton ZORC ZOC ZOC IDLY ZOR Z9 Z594 ZDA ZI ZDSHL ZDRT T DOT ZDY ZOE - - - - DOZ - - L9/ LEVEL SNITCH MEDIUM NOTE TM table I.not all-ocAWrw LT LEVEL TRANSMITTER MBR MEMBRANE RIOREACTOR LINE CODES PIPE MATERIAL ABBRMATION EOUIPMENT/INSTRUMENT NUMBERING SUBSYSTEM CODES MCC MOTOR CONTROL CENTER ME MOISTURE SENSOR MAJOR PROCESS LINE 304SS 304 STARLESS STEEL XXX-000000 (EXAMPLE) GN HEAOWORKS MOT MOTOR DI DUCTILE WON U 02 EQUALIZATION ZONE MOO MIXER —a— MINOR PROESS LONE HOGCS HOT DIPPED GALVANIZED CARBON STEEL MACE NI/STANCE 03 ANAEROBIC ZONE NZL NOZZLE —-{-— PROCESS/CLEANING MR PVC POLYVINYL OLOMOE BASIN INSTANCE 04 PRE-ANOXIC ZONE OAS OPERATOR WORK STATION FLEX REPTILE HOSE SUBSYSTEM CODE as PRE-AERATION ZONE PA PRE ELECTRICAL 8RD BRAIDED 02 HOSE EQUIPMENT/INSTRUMENT PREFIX 06 POST ANOXIC ZONE PAX PRE ANOXIC P PLC TO SCAOA FLUID CODE ABBREVIATION UNE NUMBER GROUPS 07 MEMBRANE MOREACTOR ZONE PE PRESSURE SENSOR CLXMMUNCATION as PREMEATE CONTROL PG PRESSURE GAUGE DESCRIPTOR 1 \ PROCESS CONTINUATION REF SATCA CLEANING AIR 000 OVERFLOW 09 MEMBRANE ROREACTOR ZONE AERATION pi PRESSURE INDICATOR REFCR 2 / W1HN SCOPE COS OIENCAL DOSING 100 NFWENT 10 PRE-AERATON ZONE AERATION PIT PRESSURE INDICATOR TRANSMITTER 1T -EX / $� PROCESS CONTINUATION NETT INFLUENT 200 RECYCIE/7EED FORWARD 11 SUPPLEMENTAL AERATION PLC PROGRAMMABLE LOGIC CONTROLLER <I—I DESCRIPTION 2 WHIN SCOPE OVRFL OVERFLOW 301 PERMEATE 12 INTERNAL RECYCLE PMp PUMP V REF SAT I- Nill BACKFLOW PA PLANT AIR 400 PROCESS AR/PURE OMEN 13 MPE DOSING PAIL PANEL ppEES5CCRRIPp77KXIINN PROCESS CONTINUATION PONT PERMEATE 500 CHECMCAL DOSING 14 CHEMICAL 009NG PRV PRESSURE RELIEF OR REDUCING VALVE DESCRIP110N 1> CLOT OF SCOPE pi, PLANT WATER WO CLEANING MR 15 SUPPLEMENTAL CARBON ADDITION PS1 PRESSURE WATCH HIGH </ \J PROCESS COITINUATIDI/ RAS RETURN ACTIVATED SLUDGE 700 PLANT WATER/RINSE 16 BACKWASH ZONE PA PRESSIRE SNITCH LOW \ """""`"'2 > NTH BADLFLOW RNSRECIC RINSE INTERNAL RECYCLE BOO 900 WASTE ACTIVATED SLUDGE 16 DISINFECTIORN ACTIVATED SLUDGE 17 SAN N SO PT PRESSURE SB SPECTACLE SURD TRANSMITTER WAS WASTE ACTIVATED SLUDLE 19 WAS HANDUNG SMU SUBMERGED MEMBRANE UNIT C ad-'m0°-RW"9a ) UNE NUMBER DRN DRAIN 20 SC-TAO ZONE SPE SPEECE CONE UNE NUMBERING 0XY OXYGEN 21 FEED FORWARD ZONE 51G MANUAL STOP GATE FF FEED FORWARD 22 AEROBIC DIGESTER ZONE 9UG SWAM GATE 00 LT--DI-INFLT 001 (EXAMPLE) BNB BACKWASH 23 MISCELLANEOUS SV 50lENOD VALVE T SEQUENTIAL LIE NO TC TABLET CHLORINATOR RIIO CODE TE TEMPERATURE SENSOR PPE MATERIAL TG 1F]PERATIIRE GAUGE HOMBIAI UNE 9ff TTTEMPERATURE INDICATOR 117 TEMPERATURE INDICATOR TRANSMITTER INK TANK 19t TEMPERATURE SNITCH HIGH THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF OVIVO,AND ITS OVIVO AFFILIATES,AND IS NOT TO BE DISCLOSED NOR TO BE USED EXCEPT FOR EVALUATING PROPOSALS OF OVIVO OR INSTALLING,OPERATING OR MAINTAINING OVIVO EQUIPMENT,UNLESS OTHERWISE Worldwide Experts in Water Treatment AUTHORIZED IN WAITING BY OVIVO. UNCONTROLLED COPY IF PRINTED AQUA AMERICA ,a,I Ie.I oDE40l w DO NOT SCALE PRINTS ..‘,....araan�e � AANN OCCP11 01fr 2010 NINO WALE MR B (0) O WORI(1W51AP STANDARD E50101 APPLIES P91 D SHEET I-1.11 12 O ALL R t15 RESERVED-REV A CODES LEGEND Q _ N C N lC 1 0 _ N `w tt y§ > it g` O_ L el w '6'i w-Qui 1 i o C E CY z 1 0 41 °si — �W o s _ w G RIP, C Z - o '� - - o �do I Vr pJg ;.II 1/ 1 m 1L•J D ; ol z 0 g ! I I3 i 74 30. on�o�LLo0 i P NI 01 i li u j - Ct --= - e TT 118 Fz it,g w -ait < m " �► < F 06 p3 o - of 1 t ` g 2 F < a Iv Sg N 0 • 0 F s01 � Op if = Z II [ . 5 I ® , ® o 66 6