HomeMy WebLinkAboutNCG551041_Compliance Evaluation Inspection_20211124QocuSign Envelope ID 1F9BD231-FF1D-4D82-8B25-DCB9EAE6DC51
ROY COOPER
Governor
ELIZABETH S. BISER
Secrets, y
S. DANIEL SMITH
Director
Kenneth L Walker
142 Crystal Bay Lane
Semora, NC 27343
Dear Mr. Walker:
NORTH CAROLINA
Environmental Quality
November 24, 2021
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of Coverage NCG551041
Facility: 142 Crystal Bay Lane
Person County
On November 19, 2021, Alys Hannum from the Raleigh Regional Office visited your single-
family residence (SFR) wastewater treatment system to evaluate compliance with the subject
General NPDES Permit. Your assistance during the inspection was greatly appreciated.
Our records indicate the treatment system consists of a septic tank, above ground recirculating
sand filter, tablet chlorinator with chlorine contact chamber, discharge pipe and a rip -rap apron
for post aeration.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG55104I authorize
the discharge of domestic wastewater from your treatment system to receiving waters designated
as Hyco River including Hyco Lake (classified WS-V B) in the Roanoake River Basin. The
authorized discharge is in accordance with the effluent limits and monitoring requirements
established within the General Permit. The checked boxes below show what conditions were
noted at your facility:
® Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring
Requirements, within General Permit NCG550000 requires a permittee to sample and
analyze the effluent leaving his/her treatment system prior to discharge annually.
Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen
Demand), Total Suspended Solids, Fecal Coliform and Total Residual Chlorine. During
the inspection, you informed the inspector that the effluent has not been monitored within
the last 12 months because no flow has come through the system. If the system does
begin to flow, please collect a representative sample of the effluent, have it analyzed by
a certified commercial laboratory and submit the results to this office.
Depat's. el [lnlronnenl.l poH�
North Carolina Depart ment of Environmental Qualit y 1 Division of Water Resources
Raleigh Regional Office 1 3800 Barrett Drive I Raleigh, North Carolina 27609
919 1914200
DocuSign Envelope ID: 1F9BD231-FF1D-4D82-8B25-DCB9EAE6DC51
Kenneth Walker, NCG551041
November 24, 2021
Page 2 of 2
Division records indicate the required annual fee ($60 per year) for the period ending November
22, 2022 and due November 1, 2021 has been paid. There are no overdue fees for the subject
COC.
Please continue to periodically inspect the wastewater treatment system to ensure the treatment
components are always maintained and in good operating order. You are also reminded to
maintain all monitoring data and associated maintenance records onsite for a minimum of three
years and available for inspection.
If you have questions or comments about this inspection or the requirements to take corrective
action (if applicable), please contact Alys Hannum at 919-791-4255.
Sincerely,
(DocuSigned by:
Vau u,SSa. f. �l a1n.ltit,�,
—B2916E6AB32144F
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s):EPA Water Compliance Inspection Report
cc: Kenneth Walker (kennethlwalker(u�gmail.com)
RRO/SWP Files
Laserfiche
NsiIM:>�#.\.NIA
Department ofFnNlon natal OWtl�
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 3800 Barrett Drive Raleigh. North Carolina 27609
919.791.4200
DocuSign Envelope ID: 1F9BD231-FF1D-4082-81325-DCB9EAE6DC51
United States Environmental Protection Agency
E PA Washington. D C 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 1N 1 2 LI 31 NCG551041 111 12 1 21/11/19 117 181 I 191S j 201 I
211 I
I I
I I I
I
I I I I I I I I I I I I
I I
I I I
I 1
1 1 1 l 1 1 1 1 11 1 I 1 1 1 r6
Inspection Work Days Facility Self -Monitoring
671 I 701�
Li
Evaluation Rating B1 QA
711 LI 72 I N I 731 I
LJ I I
Reserved
i74 751 1 11111180
I 1
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES oermit Number)
142 Crystal Bay Lane
142 Crystal Bay Ln
Semora NC 27343
Entry Time/Date
02:30PM 21/11/19
Permit Effective Date
21/10/12
Exit Time/Date
03:OOPM 21/11/19
Permit Expiration Date
25/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Kenneth L Walker,142 Crystal Bay Ln Semora NC 27343///
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Effluent/Receiving Wate
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Alys K Hannum DWR/RRO WQ/919-791-4255/
Signature
of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
—DocuSigned by:
11/22/2021
`— 2916E A 3 144
EPA �orm53 Rev 9-94) Previous editions are obsolete.
Page# 1
DocuSign Envelope ID: 1F9BD231-FF1D-4D82-8825-DCB9EAE6DC51
31
NPDES
NCG551041
111 121
yr/mo/day
21 /11 /19
117
Inspection Type
18 l,.l
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
DgcuSign Envelope ID: 1F9BD231-FF1D-4D82-8B25-DCB9EAE6DC51
Permit: NCG551041
Inspection Date: 11/19/2021
Owner - Facility: 142 Crystal Bay Lane
Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ • 0
application?
Is the facility as described in the permit? ■ ❑ ❑ ❑
# Are there any special conditions for the permit? ❑ ❑ ❑
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? •❑ ❑ ❑
Comment:
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Yes No NA NE