SENT VIA ELECTRONIC MAIL ONLY: NO HARD COPY WILL BE MAILED.
November 23, 2021
Ronald Lawrence, General Manager
Springdale Golf Partners LLC
Email: buddy@springdalegolf.com
SUBJECT: NOTICE OF VIOLATION
Tracking Number: NOV-2021-PC-0575
Permit No. NC0040355
Springdale Country Club WWTP
Haywood County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Springdale Country Club WWTP
on November 12, 2021. This inspection was conducted to verify that the facility is operating in compliance with
the conditions and limitations specified in NPDES WW Permit No. NC0040355. A summary of the findings and
comments noted during the inspection are provided in the enclosed copy of the inspection report.
The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville
Regional Office. The following violation(s) were noted during the inspection:
Inspection Area Description of Violation _________________________________________________________________________________________________________________________________________________________________________ Flow Measurement - Effluent The calibration for the effluent flow meter was past due at the time of the inspection.
_________________________________________________________________________________________________________________________________________________________________________
Effluent Sampling Flow proportional composite sampling is not being conducted.
_________________________________________________________________________________________________________________________________________________________________________
Effluent Pipe The effluent pipe could not be located during the inspection. Additionally, the flow of
surface water from the effluent pipe to the receiving stream is obstructed. _________________________________________________________________________________________________________________________________________________________________________
In addition, the issues below must also be addressed:
Compliance Issue(s):
There is a significant amount of rust throughout the facility, as previously mentioned in the 2013 and 2016
inspection reports. At a minimum, the 0.025 MGD package plant should be painted.
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
Remedial actions should have already been taken to correct this problem and prevent further occurrences in the
future. The Division of Water Resources may pursue enforcement action for this and any additional violations of
State law.
To prevent further action, please respond in writing to this office within 30 days upon your receipt of this Notice
of Violation regarding your plans or measures to be taken to address the indicated violations and other identified
issues, if applicable.
If you should have any questions, please do not hesitate to contact Lauren Armeni with the Water Quality
Regional Operations Section in the Asheville Regional Office at 828-296-4667.
Sincerely,
Daniel Boss, Assistant Regional Supervisor
Water Quality Regional Operations Section
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS: Inspection Report
Ec: Laserfiche
Gifford Raulerson (ORC)
Robert Barr (BORC)
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
EPA
United States Environmental Protection Agency
Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NC0040355 21/11/12 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Springdale Country Club WWTP
Springdale Country Club
Canton NC 28716
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
10:00AM 21/11/12 21/11/01
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
11:30AM 21/11/12 26/01/31
Name, Address of Responsible Official/Title/Phone and Fax Number
Gifford C Raulerson,200 Golfwatch Rd Canton NC 28716//828-235-8451/Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self-Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Lauren E Armeni DWR/ARO WQ/828-296-4500/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
11/23/2021
11/23/2021
NPDES yr/mo/day
21/11/12
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Lauren Armeni, with the Asheville Regional Office, conducted a Compliance Evaluation Inspection of
the Springdale Country Club WWTP on November 12, 2021. This inspection was conducted to
determine whether the facility is being operated and maintained in compliance with NPDES Permit
No. NC0040355. Gifford Raulerson (ORC) and Robert Barr (BORC) were present and assisted in the
inspection.
The following items were noted during the inspection:
Operations & Maintenance: Overall, the majority of the facility still has rust issues and should be
repainted to extend the lifespan of the plant. Mr. Raulerson indicated that the owner would eventually
like to replace the current system they have since all of the package plants aren't being used due to
low flow. At a minimum, the 0.025 MGD package plant should be repainted since it is the only one
currently in use and this issue has been mentioned in the 2013 and 2016 CEI reports.
Flow Meter - Effluent: The calibration of the flow meter expired on March 9, 2021 and it needs to be
recalibrated.
Effluent Sampling: Because the capacity of the plant is greater than 0.030 MGD, flow-proportional
composite sampling is required. Currently, timed-composite sampling is being conducted. A
composite sampler will need to be installed and a flow meter used that is compatible.
Effluent Pipe: The effluent pipe could not be observed during the inspection because it was covered
with leaves and other natural debris. Additionally, the flow of surface water from the effluent pipe to
the receiving stream is obstructed with bamboo and other natural debris. It needs to be determined
whether there is an easement for the outfall on the property across the street so this area can be
cleared to allow unobstructed flow.
The following violations were noted during the inspection:
1.Flow Meter - Effluent: The calibration for the effluent flow meter was past due at the time of the
inspection.
2.Effluent Sampling: Flow-proportional composite sampling is not being conducted.
3.Effluent Pipe: The effluent pipe could not be located during the inspection. Additionally, the flow of
surface water from the effluent pipe to the receiving stream is obstructed.
NC0040355 17 (Cont.)
Page#2
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
Permit:NC0040355
Inspection Date:11/12/2021
Owner - Facility:
Inspection Type:
Springdale Country Club WWTP
Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
The current permit issued September 16, 2021 lists the incorrect sizes of the package
plants. According to Buddy Lawrence (General Manager/Chief Operating Officer) on
November 16, 2021, the following are the correct sizes of the package plants: 0.005
MGD, 0.005 MGD, 0.015 MGD, and 0.025 MGD. Ms. Sydney Carpenter in the DEQ
Raleigh Permitting Unit was informed and will make the correction.
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Currently, the 0.025 MGD package plant is the only one in use due to low flow. Gifford
Raulerson, ORC, measures dissolved oxygen and settleability in the aeration basin.
There is still visible rust throughout all the treatment units. See summary for details.
Comment:
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain-of-custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Page#3
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
Permit:NC0040355
Inspection Date:11/12/2021
Owner - Facility:
Inspection Type:
Springdale Country Club WWTP
Compliance Evaluation
Record Keeping Yes No NA NE
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Comment:
Bar Screens Yes No NA NE
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Solids from the bar screen are disposed of in a trash can on-site that the ORC empties
into a dumpster once a week.
Comment:
Equalization Basins Yes No NA NE
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
The plant has one 20,000-gallon EQ basin. The basin is not aerated, but is
installed and can be turned on if needed. Audible and visual high water alarms
have been fixed and are in working order. Soda ash is added to the basin for pH
control as needed.
Comment:
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Page#4
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
Permit:NC0040355
Inspection Date:11/12/2021
Owner - Facility:
Inspection Type:
Springdale Country Club WWTP
Compliance Evaluation
Aeration Basins Yes No NA NE
Type of aeration system Diffused
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin’s surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/l)
The 0.025 MGD basin is currently being used, and the 0.015 MGD basin and two
0.0070 MGD basins have not been used for years. Mr. Barr indicated that one of the
blowers would need to be replaced in the 0.025 MGD basin and that the diffusers had
been replaced. Dissolved oxygen was ~8.45 mg/L at the time of the inspection. The
blowers had just turned on right before DO was measured and temperatures were low
that day. Blowers are on timers to cycle on and off every 15 minutes throughout the
day. Settleability was 100 mL after thirty minutes. Mr. Raulerson indicated that the
sludge is old since the plant operates at such a low flow.
Comment:
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth)
At the time of the inspection, the sludge blanket was around 7' in 9.5' deep clarifier,
which is undesirably high, but with the low flow the plant does not have issues with
solids.
Comment:
Aerobic Digester Yes No NA NE
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
Page#5
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
Permit:NC0040355
Inspection Date:11/12/2021
Owner - Facility:
Inspection Type:
Springdale Country Club WWTP
Compliance Evaluation
Aerobic Digester Yes No NA NE
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
The digester is a tertiary filter that is no longer in use. The digester can be aerated,
but is currently being used as a facultative digester. Sludge is wasted to the digester
approxmately once every two months and the solids in the digester are pumped out
once a year due to low flow conditions.
Comment:
Disinfection-Tablet Yes No NA NE
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?2
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de-chlorination?
There are four chlorination tubes, two of which were in use at the time of the
inspection. A submersible pump is kept in the chlorine contact chamber and solids
are pumped out monthly into the EQ basin.
Comment:
De-chlorination Yes No NA NE
Type of system ?Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de-chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Are tablet de-chlorinators operational?
Number of tubes in use?1
There are two dechlorination tubes, one of which was in use at the time of
the inspection.
Comment:
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Page#6
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
Permit:NC0040355
Inspection Date:11/12/2021
Owner - Facility:
Inspection Type:
Springdale Country Club WWTP
Compliance Evaluation
Flow Measurement - Effluent Yes No NA NE
The flow meter was last calibrated on March 9, 2020 by Horizon Engineering and
Consulting, Inc. Calibration is past due for the meter. See summary for details.
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
The effluent pipe could not be seen at the time of the inspection. Mr. Raulerson knew
the general location of the pipe, but leaves and other natural debris were covering it.
Discharge from the effluent pipe enters an unnamed tributary, but due to an overgrown
area of bamboo between the Pigeon River and tributary, the water appears to pool and
cannot directly discharge into the Pigeon River. See summary for details.
Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
The sampling fridge was reading 5.0 degrees Celsius at the time of the inspection. It
was discovered that timed-composite sampling was being conducted. Because the
plant is rated at greater than 0.030 MGD, flow-proportional sampling is required. See
summary for details.
Comment:
Standby Power Yes No NA NE
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up
power?
Is the generator fuel level monitored?
Page#7
DocuSign Envelope ID: 03E79740-9479-4E3F-82E1-3F8EBCCE5200
Permit:NC0040355
Inspection Date:11/12/2021
Owner - Facility:
Inspection Type:
Springdale Country Club WWTP
Compliance Evaluation
Standby Power Yes No NA NE
The WWTP does not have standby power. Mr. Raulerson believes that the plant has
adequate storage capacity in the event of a power failure since three of the package
plants are not currently in use. The plant has an average flow of approximately 5,000
GPD.
Comment:
Page#8