HomeMy WebLinkAboutNCG550689_Compliance Evaluation Inspection_20211108ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
S. DANIEL SMITH
Director
Patricia Bowyer/Michael Smith
117 Paulas Parkway Lane
Mooresville, North Carolina 28117
Dear Ms. Bowyer/Mr. Smith:
NORTH CAROLINA
Environmental Quality
November 8, 2021
Subject: Compliance Evaluation Inspection
117 Paulas Parkway Lane Residence
NPDES General Permit No. NCG550689
Iredell County
Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the 117
Paulas Parkway Lane/Iredell County residence on November 4, 2021, by Mr. Wes Bell of this Office.
Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192,
or via email at wes.bell@a,ncdenr.gov.
Enclosure: Inspection Report
NORTH
Dep®rlmont of Environmental Onolit
Sincerely,
DocuSigned by:
A H P,xs.i
F161 FB69A2D84A3...
fo r
W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
North Carolina Department of Environmental Quality 1 Division of Water Resources
Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115
704.663.1699
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code
1 IN I 2 IL
21IIIIII
I
NPDES yr/mo/day Inspection
3 I NCG550689 111 121 21/11/04 117
Type
1810I
IIIIIIIIIII
Inspector Fac Type
19I S I 2011
IIIIIIIIIIIIIIIIII I IIIIII
P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67I1.0 I 70I3 I 71IN I 72 I N I 73I 1 74 751
I I 1
I I I I I I 180
l
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES oermit Number)
117 Paulas Parkway Lane
117 Paulas Pkwy Ln
Mooresville NC 28117
Entry Time/Date
01:15PM 21/11/04
Permit Effective Date
19/11/07
Exit Time/Date
01:47PM 21/11/04
Permit Expiration Date
20/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Michael F Smith/Co-Owner//
Patricia A Bowyer/Co-Owner/704-877-9360 /
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Patricia Bowyer,117 Paulas Parkway Ln Mooresville NC 28117///
Yes
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Wes Bell
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
—Docusigned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 11/8/2021
"-A61696D90CC3437...
Signature of Management
Andrew Pitn
Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by:
r DWR/MRO WQ/704-663-1699 Ext.2180/ 11.8.21
�F16 F 69A D84A3.
EPA Form 3560-3 (Rev 9-94) i-'revious editions are obsolete.
Page# 1
NPDES yr/mo/day
31 NCG550689 111 121 21/11/04
I17
Inspection Type
18 [j
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
Permit: NCG550689
Inspection Date: 11/04/2021
Owner - Facility: 117 Paulas Parkway Lane
Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ El � ❑
application?
Is the facility as described in the permit? • ❑ ❑ ❑
# Are there any special conditions for the permit? ❑ ❑ • ❑
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑
Comment: The last compliance evaluation inspection at this facility was performed by DWR staff
on 8/1/17.
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
Comment: Pace Analytical Services has been contracted to perform all permit -required analyses.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? ❑ ❑ • ❑
Is sample collected below all treatment units? • ❑ ❑ ❑
Is proper volume collected? • ❑ ❑ ❑
Is the tubing clean? ❑ ❑ • ❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ • ❑
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑
representative)?
Comment: The subject permit requires grab samples. No limit violations were noted during the
review of the laboratory analyses.
The permittee must ensure flow is measured (estimated) during sampling event and
nutrient samples (total phosphorus, total nitrogen and ammonia) are collected during
future sampling events.
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
•
Yes No NA NE
❑ ❑ ❑
Page# 3
Permit: NCG550689
Inspection Date: 11/04/2021
Owner - Facility: 117 Paulas Parkway Lane
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable DOME
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The wastewater facility appeared to be properly operated and well maintained.
Septic Tank
(If pumps are used) Is an audible and visual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
Yes No NA NE
❑ ❑ • ❑
❑ ❑ • ❑
Comment: The septic tank was last pump approximately 6-7 years ago. The septic tank will be
pumped out on 11/12/21 by a contracted company. The permittee must ensure that
the septic tank is pumped out according to the permit requirements.
Sand Filters (Low rate)
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re -circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1)
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The surface sandfilter (with gravel cover) and recirculation pump tank were operational
and in service.
Disinfection -Tablet
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de -chlorination?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
2
❑ ❑ ❑ •
• ❑ ❑ ❑
❑ ❑ ❑ •
Comment: Approved wastewater disinfection tablets (calcium hypochlorite) were being used.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ ❑ •
Page# 4
Permit: NCG550689
Inspection Date: 11/04/2021
Owner - Facility: 117 Paulas Parkway Lane
Inspection Type: Compliance Evaluation
Effluent Pipe
If effluent (diffuser pipes are required) are they operating properly?
Yes No NA NE
❑ ❑ • ❑
Comment: The facility was not discharging at the time of the inspection; however, the wastewater
in the tablet chlorinator/chlorine contact chamber vault appeared clear with no floatable
solids or foam.
Page# 5