HomeMy WebLinkAboutNC0073539_Compliance Evaluation Inspection_20211122ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
S. DANIEL SMITH
Director
Shannon Becker, President
Aqua North Carolina, Inc.
202 MacKenan Court
Cary, North Carolina 27511
Dear Mr. Becker:
NORTH CAROLINA
Environmental Quality
November 22, 2021
Subject: Compliance Evaluation Inspection
Willowbrook Subdivision WWTP
NPDES Permit No. NC0073539
Mecklenburg County
Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject
facility on November 16, 2021, by Mr. Wes Bell of this Office. Please advise the facility's Operator -in -Responsible Charge
(ORC) of our findings by forwarding a copy of the enclosed report.
Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192,
or via email at wes.bell@ncdenr.gov.
Enclosure: Inspection Report
NORTH
Dep®rlmont of Environmental Onolit
Sincerely,
DocuSigned by:
A w H Nut4
F161 FB69A2D84A3...
fo r
W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
North Carolina Department of Environmental Quality 1 Division of Water Resources
Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115
704.663.1699
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code
1 IN I 2 IL
21 1 1 1 1
1
NPDES yr/mo/day Inspection
I 3 I NC0073539 111 121 21/11/16 I17
Type
1810I
I I 1 1 1
Inspector Fac Type
191 S I 2011
1 1 1 1 11 1 1 1 I I I 1 1 1 1 1 1 I I I I I
1 11
1 1 1 I 1 P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67I2.0 I 70I4 I 71IN I 72 I N I 73I 1 74 751
I I 1
I I I I I I 180
l
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Willowbrook Subdivision WWTP
12309 Ramah Creek Ct
Huntersville NC 28078
Entry Time/Date
12:25PM 21/11/16
Permit Effective Date
19/02/01
Exit Time/Date
02:15PM 21/11/16
Permit Expiration Date
23/11/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Daniel G Wimpey/ORC/337-215-1165/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Shannon V Becker,202 Mackanan Ct Cary NC 275116447//919-653-5570/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Wes Bell
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
-Docusiyned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 11/22/2021
"-A61696D90CC3437...
Signature of Ma
Andrew Pitn
RvenliOsell Reviewer Agency/Office/Phone and Fax Numbers Date
rA444144' H P 3WR/MRO WQ/704-663-1699 Ext.2180/ 11.22.21
F161 FB69A2D84A3...
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
NPDES yr/mo/day
31 NC0073539 111 121 21/11/16
I17
Inspection Type
18 [j
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
Permit: NC0073539
Inspection Date: 11/16/2021
Owner - Facility: Willowbrook Subdivision WWTP
Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ •❑
application?
Is the facility as described in the permit? • ❑ ❑ ❑
# Are there any special conditions for the permit? ❑ ❑ • ❑
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑
Comment: Overall, the facility is adequately described in the Permit; however, the description
does not include an aerated flow equalization tank. The facility description should be
updated to include the equalization tank during the next permit renewal process.
The last compliance evaluation inspection at this facility was performed by DWR staff
on 9/25/19.
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? • ❑ ❑ ❑
Is all required information readily available, complete and current? • ❑ ❑ ❑
Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ ❑ ❑
Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑
Is the chain -of -custody complete? • ❑ ❑ ❑
Dates, times and location of sampling •
Name of individual performing the sampling •
Results of analysis and calibration •
Dates of analysis •
Name of person performing analyses •
Transported COCs ■
Are DMRs complete: do they include all permit parameters? • ❑ ❑ ❑
Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ • ❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ • ❑
operator on each shift?
Is the ORC visitation log available and current? • ❑ ❑ ❑
Is the ORC certified at grade equal to or higher than the facility classification? • ❑ ❑ ❑
Is the backup operator certified at one grade less or greater than the facility • ❑ ❑ ❑
classification?
Is a copy of the current NPDES permit available on site? • ❑ ❑ ❑
Facility has copy of previous year's Annual Report on file for review? ❑ ❑ • ❑
Page# 3
Permit: NC0073539
Inspection Date: 11/16/2021
Owner - Facility: Willowbrook Subdivision WWTP
Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Comment: The records reviewed during the inspection were organized and well maintained.
Discharge monitoring reports (eDMRs) were reviewed for the period October 2020
through September 2021. No effluent limit and/or monitoring violations were reported.
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: On -site effluent field analyses (dissolved oxygen, pH, temperature and total residual
chlorine) are performed under the Aqua NC's field laboratory certification #5035.
Water Tech Labs (Certification #50) has been contracted to provide analytical support.
The ORC must ensure all future calibration logs have the meter serial numbers listed.
In addition, the ORC must ensure the theoretical DO is documented (for comparison)
during all future DO calibration/verification events. A copy of the NC
Wastewater/Groundwater Laboratory Certification approved procedure for the
analysis/calibration of DO has been emailed to the ORC for reference.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? • ❑ ❑ ❑
Is sample collected below all treatment units? • ❑ ❑ ❑
Is proper volume collected? • ❑ ❑ ❑
Is the tubing clean? ■ ❑ El El
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 • El El El
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ El El
representative)?
Comment: The subject permit requires effluent composite and grab samples.
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, • El El El
and sampling location)?
Comment:
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
Yes No NA NE
Page# 4
Permit: NC0073539
Inspection Date: 11/16/2021
Owner - Facility: Willowbrook Subdivision WWTP
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The wastewater treatment facility appeared to be properly operated and well
maintained. Process control measurements were being documented and maintained
on -site.
Equalization Basins
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The telemetry type alarm system (high water) was operational during the on -site test.
Bar Screens
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Yes No NA NE
•
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The old bar screen has been removed.
Screenings are transported and disposed into the dumpster located at the Hwy.
150/River Park WWTP. The dumpster contents are disposed at a permitted landfill.
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Type of aeration system Diffused
Is the basin free of dead spots? • ❑ ❑ ❑
Are surface aerators and mixers operational? ❑ ❑ • ❑
Are the diffusers operational? • ❑ ❑ ❑
Page# 5
Permit: NC0073539
Inspection Date: 11/16/2021
Owner - Facility: Willowbrook Subdivision WWTP
Inspection Type: Compliance Evaluation
Aeration Basins Yes No NA NE
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/I)
• II El El El
•
❑ ❑ ❑
❑ ❑ ❑
Comment: Soda ash is added on an as -needed basis to maintain appropriate alkalinity/pH levels.
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: A significant amount of floating solids was observed in the clarifier; however, the solids
were being contained in the clarifier and not entering the effluent.
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? • El ❑ ❑
Are the tablets the proper size and type? • El El El
Number of tubes in use? 3
Is the level of chlorine residual acceptable? • El El El
Is the contact chamber free of growth, or sludge buildup? • El El El
Is there chlorine residual prior to de -chlorination? • El El El
Comment: Calcium hypochlorite tablets were used for disinfection.
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Yes No NA NE
Page# 6
Permit: NC0073539
Inspection Date: 11/16/2021
Owner - Facility: Willowbrook Subdivision WWTP
Inspection Type: Compliance Evaluation
Flow Measurement - Effluent
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Yes No NA NE
• ❑ ❑ ❑
Comment: The flow meter is calibrated annually and was last calibrated by Aqua N.C. staff on
1/27/21.
De -chlorination Yes No NA NE
Type of system ? Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ • ❑
Is storage appropriate for cylinders? El El • El
# Is de -chlorination substance stored away from chlorine containers? • El El El
Comment:
Are the tablets the proper size and type?
Are tablet de -chlorinators operational?
Number of tubes in use?
4
• ❑ ❑ ❑
▪ ❑ ❑ ❑
Comment: Sodium Sulfite tablets were used for dechlorination. Post aeration is provided following
dechlorination.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: The effluent appeared clear with no floatable solids or foam. The receiving stream did
not appear to be negatively impacted.
Aerobic Digester Yes No NA NE
Is the capacity adequate? • El El El
Is the mixing adequate? • El El El
Is the site free of excessive foaming in the tank? • El El El
# Is the odor acceptable? • El El El
# Is tankage available for properly waste sludge? • El El El
Comment: Wastewater solids are removed by a contracted company (Lake Norman Sewer &
Septic Services).
Standby Power
Is automatically activated standby power available?
Yes No NA NE
Page# 7
Permit: NC0073539
Inspection Date: 11/16/2021
Owner - Facility: Willowbrook Subdivision WWTP
Inspection Type: Compliance Evaluation
Standby Power
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up
power?
Is the generator fuel level monitored?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The backup generator is tested weekly (automatically) and placed under load
semi-annually (at a minimum). Managed Generator Services has been contracted to
service the generator annually.
Page# 8