Loading...
HomeMy WebLinkAboutNC0063860_Compliance Evaluation Inspection_20211122ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Shannon Becker, President Aqua North Carolina, Inc. 202 MacKenan Court Cary, North Carolina 27511 Dear Mr. Becker: NORTH CAROLINA Environmental Quality November 22, 2021 Subject: Compliance Evaluation Inspection Harbor Estates WWTP NPDES Permit No. NC0063860 Mecklenburg County Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject facility on November 16, 2021, by Mr. Wes Bell of this Office. Please advise the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding a copy of the enclosed report. Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192, or via email at wes.bell@ncdenr.gov. Enclosure: Inspection Report NORTH Dep®rlmont of Environmental Onolit Sincerely, ,-DocuSigned by: A4.44to H P;xa,t F161F869A2D84A3... fo r W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 IL 21 1 1 1 1 1 NPDES yr/mo/day Inspection I 3 I NC0063860 111 121 21/11/16 117 Type 1810I I I 1 1 1 Inspector Fac Type 191 S I 2011 1 1 1 1 11 1 1 1 I I I 1 1 1 1 1 1 I I I I I 1 11 1 1 1 I 1 P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67I2.0 I 70I4 I 71IN I 72 I N I 73I 1 74 751 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Harbor Estates WWTP NCSR 1113 Charlotte NC 28212 Entry Time/Date 09:15AM 21/11/16 Permit Effective Date 21/07/01 Exit Time/Date 11:45AM 21/11/16 Permit Expiration Date 25/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Daniel G Wimpey/ORC/337-215-1165/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Shannon V Becker,202 Mackanan Ct Cary NC 275116447//919-653-5570/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Wes Bell of Inspector(s) Agency/Office/Phone and Fax Numbers Date �pocusiyned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 11/22/2021 ZO(4- Bell "-A61696D9OCC3437... Signature of Ma Andrew Pit ritmairftiiNetReviewer Agency/Office/Phone and Fax Numbers Date rA4I4 41 H P44' WR/MRO WQ/704-663-1699 Ext.2180/ 11.22.21 F161 FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES yr/mo/day 31 NC0063860 111 121 21/11/16 I17 Inspection Type 18 [j 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# 2 Permit: NC0063860 Inspection Date: 11/16/2021 Owner - Facility: Harbor Estates WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? • ❑ ❑ ❑ # Are there any special conditions for the permit? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: The last compliance evaluation inspection at this facility was performed by DWR staff on 9/25/19. No introduction of filter backwash from ion exchange water supply well treatment systems (Fleetwood Acres and/or Old South Lane) has occurred to date. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • ❑ ❑ ❑ Is all required information readily available, complete and current? • ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑ Is the chain -of -custody complete? • ❑ ❑ ❑ Dates, times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? • ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ • ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ • ❑ operator on each shift? Is the ORC visitation log available and current? • ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? • ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility • ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? • ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ • ❑ Page# 3 Permit: NC0063860 Inspection Date: 11/16/2021 Owner - Facility: Harbor Estates WWTP Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Comment: Discharge monitoring reports (eDMRs) were reviewed for the period October 2020 through September 2021. No effluent limit and/or monitoring violations were reported. Effluent chronic toxicity failures were reported in April and May 2021; however, the permit only requires monitor only for this parameter. The September 2021 eDMR will be revised to include a statement (Comments Section) that no introduction of off -site wastewater occurred during the quarter. Note: This statement must be included on all future eDMRs that quarterly sampling has occurred and no off -site wastewaters were introduced per Permit [Part 1, Section A(1) footnote #5]. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: On -site effluent field analyses (dissolved oxygen, pH, temperature and total residual chlorine) are performed under the Aqua NC's field laboratory certification #5035. Water Tech Labs (Certification #50) has also been contracted to provide analytical support. The ORC must ensure all future calibration logs have the meter serial numbers listed. In addition the ORC must ensure the theoretical dissolved oxygen (DO) level is documented (for comparison) during all future DO calibration/verification events. A copy of the NC Wastewater/Groundwater Laboratory Certification approved procedure for the analysis/calibration of DO has been emailed to the ORC for reference. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • ❑ ❑ ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? ■ ❑ ❑ ❑ Is the tubing clean? ■ ❑ El El # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • El El El degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ El El representative)? Comment: The subject permit requires effluent composite and grab samples. Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Yes No NA NE Page# 4 Permit: NC0063860 Inspection Date: 11/16/2021 Owner - Facility: Harbor Estates WWTP Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable MODE Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The wastewater treatment facility appeared to be properly operated and well maintained. Process control measurements were being documented and maintained on -site. The metal structure housing the aeration basins, clarifier and chlorination systems has been repaired and coated. Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Yes No NA NE • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Screenings are transported and disposed into the dumpster located at the Hwy. 150/River Park WWTP. The dumpster contents are disposed at a permitted landfill. Equalization Basins Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? # Is basin size/volume adequate? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The telemetry type alarm system (high water) was operational during the on -site test. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ • ❑ Are the diffusers operational? • ❑ ❑ ❑ Page# 5 Permit: NC0063860 Inspection Date: 11/16/2021 Owner - Facility: Harbor Estates WWTP Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) • • ❑ ❑ ❑ ❑ ❑ ❑ Comment: Soda ash is added on an as -needed basis to maintain appropriate alkalinity/pH levels. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Comment: Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? • ❑ ❑ ❑ Are the tablets the proper size and type? • El El El Number of tubes in use? 4 Is the level of chlorine residual acceptable? • ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? ■ El El El Is there chlorine residual prior to de -chlorination? • El El El Comment: Calcium hypochlorite tablets were used for disinfection. De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? El El • El Is storage appropriate for cylinders? El ❑ • El Page# 6 Permit: NC0063860 Inspection Date: 11/16/2021 Owner - Facility: Harbor Estates WWTP Inspection Type: Compliance Evaluation De -chlorination # Is de -chlorination substance stored away from chlorine containers? Comment: Yes No NA NE II El El El Are the tablets the proper size and type? • ❑ ❑ ❑ Are tablet de -chlorinators operational? • ❑ ❑ ❑ Number of tubes in use? 8 Comment: Sodium Sulfite tablets were used for dechlorination (dual tablet units). Post aeration is provided following dechlorination. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Comment: The flow meter is calibrated annually and was last calibrated by Aqua NC staff on 1/27/21. Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑ Are all pumps present? • ❑ ❑ ❑ Are all pumps operable? • ❑ ❑ ❑ Are float controls operable? • ❑ ❑ ❑ Is SCADA telemetry available and operational? • El ❑ ❑ Is audible and visual alarm available and operational? • ❑ ❑ ❑ Comment: The telemetry type alarm system (high water) was operational during the on -site test. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: The effluent appeared clear with no floatable solids or foam. The effluent is discharged (via submerged outfall) into the receiving stream. Yes No NA NE ❑ ❑ • ❑ ❑ ❑ ❑ • Aerobic Digester Yes No NA NE Is the capacity adequate? • ❑ ❑ ❑ Page# 7 Permit: NC0063860 Inspection Date: 11/16/2021 Owner - Facility: Harbor Estates WWTP Inspection Type: Compliance Evaluation Aerobic Digester Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Wastewater solids are removed by a contracted company (Lake Norman Sewer & Septic Services). Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The backup generator is tested weekly and placed under semi-annually (at a minimum). Managed Generator Services has been contracted to service the generator annually. Page# 8