Loading...
HomeMy WebLinkAboutWQ0032169_Regional Office Historical File Pre 20187 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality September 12, 2007 Mr. David Treme, City Manager City of Salisbury 217 South Main Street PO Box 479 Salisbury, NC 28145 Subject: Permit No. WQ0032169 City of Salisbury Allied Bearing Company Wastewater Collection System Extension Rowan County, North Carolina Dear Mr. Treme, In accordance with your application received on August 29, 2007, we are forwarding herewith Permit No. WQ0032169, dated September 12, 2007, to the City if Salisbury for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted• February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based. on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycledll0% Post Consumer Paper Phone: (704) 663-1699 Fax: (704) 663-6040 N�oy�` tCarolina Naturally Mr. Treme Page 2 September 12, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Salisbury for the construction and operation of approximately 194 linear feet of 8- inch gravity sewer and the discharge of 250 gallons per day of collected domestic wastewater into the City of Salisbury existing sewerage system, pursuant to the application received August 29, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Salisbury WWTP (NPDES No. NC0023884) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. merely, for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit File Darryl Wagoner, Salisbury Engineering and Planning Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMEN?` COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. ' 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 12th day of September, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032169 3 Fast Track Engineering Certification Permit No. WQ0032169 September 12, 2007 Owner/WVVfPIWQCS David Treme City of Salisbury 217 S. Main Street PO Box 479 Salisbury, NC 28144 PE Darryl Wagoner Salisbury Engineering and Planning 516 —A North Main Street Salisbury, NC 28144 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Allied Bearing Company, a Rowan County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST -TRACK APPLICATION foar G "t TT°" SEWERS, PUMP STATIONS, A.N1II FORCE M.(S PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD (to be cation hlumc (to be completed by D Owner: 1a. C of Salisb Full Legal Name (corrmpany, mun 1 b. David W. Treme, C Man der Signing Official Name and Title (Please review 15A NCCAC 2H .0206(b) for a The legal entitywho will own this system is: 0 Individual Federal Municipality 0 StatelCounty 0 Private Partnership 0 Corporation 0 Other (sp CO 1 d. P. O. Box 479 Mailing Address If. N.C. z 0 State 1 h, 704-638-82t3 704-638-8458 Telephone Facsimile 2. Project (Facility) information: 2a. Allied Bearing Company Brief Project Name (per 3, Contact Person: 3a, Darryl Wagoner, Owner SE&P Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, 704-633-8550 3c. s_teltcipaaol,com le. Salisbury City lg. 28145 Zip 1j, dmik iisburync.v E-mat 2b. Rowan fer to this name County Where Project is Located Phone Number E-mail 1. Project is ® New 0 Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding an phase, changing line sizeliength, etc.). Only include the modified information in this permit application - do not duplicate project information in !=• 7) and B(10-11) that has already been included in the original permit. Owner is Public (skip to Item B(3)) If private, applicant will be: El Retaining Ownership (i.e. store, church, single ofhce, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to item B(2b)) City of alisbu 0 Private (go to Item 2(a)) er Treatment F Rowan WWTP (Grants Creek T Name of VM/TF City of Salisbury Owner of Downstream Sewe 6Theorigin of this wastewater b. 8"' iRecevin El Residential Subdivision © Apartments/Condominiums El Mobile Horne Park Q School 0 Restaurant ►;+i Office Volume of wastewater to be *Do not include previously 0 Treating Gravit Sewer Size 0 Force h 0 Car Wash 0 Institution © Hospital 0 Church 0 Nursing Home © Other (specify): his particular project 22 ations 2be If IgA, facilities owned by a (must choose one 0 Public Utility (Instruction 111) Q Homeowner Assoc./Developer jlnstrucUon IV) er From 4b. NC 100 % Domes ticlComrnercial % Industrial % Other (specify): If the permitted flow is zero, indicate why: Q Interceptor Line - Flow will be permitted in subsequent permits that connect to this line Q Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 lO z H z 0 V z 0 2 0 z 2 W a. • 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1 2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). 10 employees at 25 GPD/employee 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8I? ENTER TOTAL UNE LENGTH IN MILES Length (feet) 194' 0.04 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on _plans for cross-reference) Design Flow (MOD) Operational Point GPM @ TDH Gravity or Force Main (use the pull down menu) Gravity Power Reliability Option (1- dual line feed; 2- permanent generator w/ATS; 3- portable generator wltelemetry; 4-wet well storag+z 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance Is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® WA Sedimentation and Erosion Control Plan? ❑ Yes 0 No ® N/A Stormwater? ❑ Yes D No ® NIA 14. Does this project involve aerial lines or siphons? Check if yes: ❑ `[hese.lines wilLbe_consideredhiatu riortkandrnust be checked_once evenr_skmordhs 15. Does this project have gravity sewer lines designed at minimum slopes? ❑ Be aware that the Division will not accept installed fines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. ,T9poZ©ne - USGS China Grove (NC) 'lope Map r asc 1 V.I. s 0.3 0.6 0.9 1.2 1.5 km 0.2 0.4 0.6 0.8 UTM 17 541865E 3941936N (NAD27) USGS China Grove (NC) Quadrangle Projection is UTM Zone 17 NAD83 Datum 1 mi fr1-_, 7 . 4 : e5 G= .26,9 http://www.topozone. cam/print, asp? lat=3 5.62212& lon=-80.5 3 77& sizc—l&syrn shaw=n&u=... 6/ 1 /2007 SALISBURY ENGINEERING & PLANNING 516-A NORTH MAIN STREET • SALI aBURY, NC 28144 DARRYL L. WAGONER, RE. 704-633 n855O August 28, 2007 DENR Division of Water Quality 610 East Center Ave., Suite 301 Mooresville, N. C. 28115 RE: Sanitary Sewer Extensions to serve Allied. Bearing Company Rowan County Dear Sir or Madam: Please find enclosed two applications for approval for the above referenced project. Please advise immediately if additional information is required. Sincerely, Enclosures Central Files: APS SWP 09111 /07 Permit Number W00032169 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 250 Facility Facility Name Allied Bearing Company Location Address Owner Major/Minor Region Minor Mooresville County Rowan Facility Contact 'Affiliation Owner Name Owner Type City of Salisbury Government - Municipal DateslEvents Orlg Issue App Received Draft Initiated 09/12/07 08/29/07 Scheduled Issuance Owner Affiliation David Treme, City Manager PO Box 479 Salisbury NC 28145 Public Notice Issue Effective Expiration 09/12/07 09/12/07 Regulated Activities _ Reauested/Received Events Office Additional information requested Wastewater collection Additional Information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality January 22, 2008 David Treme, City Manager City of Salisbury P.O. Box 479 Salisbury, North Carolina 28145 SUBJECT: Allied Bearing Company Permit No. WQ0032169 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on November 27, 2007. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. 1f this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically 'transferable. Form PNOCF-S can be downloaded from httr. ://h2o.enr.state.nc.us/ndpu/ndpuapps.html#Sewer. 1f you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sincerely, ImiRobert Krebs b Surface Water Protection Regional Supervisor Enclosure Cc: Darryl Wagoner, Salisbury Engineering & Planning Surface Water Protection Section Central Files (certification page only) One Pretreatment, Emergency Response and Collection Systems Unit Internet httpilh2o.enr.nc.state.uslndpu NorthCarolina 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Naturally Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled110% post -consumer paper Fast Track Engineering Certification Permit No. WQ0032169 September 12, 2007 Owner /+'W TPPWQCS David Treme City of Salisbury 217 S, Main Street PO Box 479 Salisbury, NC 28144 PE Darryl Wagoner Salisbury Engineering and Planning 516 --A North Main Street Salisbury, NC 28144 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater ction system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the re cc rd drawings or in wrrtten summary form 'omit modifications are required for any changes resintin in non-compliance with this_p_ermit re ulations rar minimum design criteria colle This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEERS CERTIFICATION C Partial E Final Plr- w40-1-, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (r,periodically, LJ weekly, Li full time) the construction of Allied gearing Company, a Rowan County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. SAL SBURY ENGINEERING & PLANNING 51 , A NORTH MAIN STREET • SALISRUI Y, NC 28144 November 26, 2007 Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, NC 28115 RE: Allied Bearing Co. WQ©032169 Rowan County Dear Sir or Madam: DARRYL L. WAGONER, P.E. 704 633-8550 IVE NCD Surface Wt et n l have enclosed :record drawings and an Engineer's certification far the referenced project. All work is complete and has been installed in substantial compliance with the approved plans. Please contact me if you need additional information on this project. Sincerely, Darryl W:a Enclosures