Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031659_Regional Office Historical File Pre 2018
6' Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources ' Alan W. Klimek, P.H. Director Division of Water Quality May 2, 2007 Mr. Wilmer Melton, Ill, Public Works Director City of Kannapolis 1401 Bethpage Road Kannapolis, North Carolina 28081 Subject: Permit No. WQ0031659 City of Kannapolis The Club at Irish Creek Trunk Sewer Wastewater Collection System Extension Rowan County, North Carolina Dear Mr. Melton: In accordance with your application received on April 26, 2007, we are forwarding herewith Permit No. WQ0031659, dated May 2, 2007, to the City of Kannapolis for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone; 704-663-1699 / Fax: 704-663-6040 / Internet: http://h2o.enr.state.nc.us An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper N nrthCarolina Naturally Wilmer Melton, ill Page 2 May 2, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Kannapolis for the construction and operation of approximately 2,716 linear feet of 8-inch gravity sewer to serve as an interceptor line as part of The Club at Irish Creek Trunk Sewer project; and the discharge of 0 gallons per day of collected domestic wastewater (flow will be permitted in subsequent permits that connect to this line) into the City of Kannapolis' existing sewerage system, pursuant to the application received April 26, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Water & Sewer Authority of Cabarrus County Rocky River WWTP (NPDES No. NC0036269) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between the City of Kannapolis and the Water & Sewer Authority of Cabarrus County for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerni,ng this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, -7Z4 for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (Fast Track Sewer Ext Files) Raymond Waugh, P.E., LandDesign, Inc. Surface Water Protection Central Files PERCS Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403.. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at al! times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b, A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 1 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spilt report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 12. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is a unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case by case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. Permit issued this the 2nd day of May, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031659 3 Fast Track Engineering Certification Permit No. WQ0031659 May 2, 2007 Wilmer Melton City of Kannapolis 1401 Bethpage Rd. Kannapolis, NC 28081 Raymond Waugh, P.E. LandDesign, Inc. 223 North Graham St. Charlotte, NC 28202 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification, and all required supporting documentation, have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of The Club at Irish Creek Trunk Sewer, Rowan County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NORTH CAROLINA 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST-T APPLICATION for GRAVITY SEWERS, PUMP STATION AND FO CE t'VViAI NS PAGE 3 z 0 USE THE TAB KEY TO MOVE FROM FIELI[1 TO FIELD! application Number (to be completed by DWQ) Owner. City of Kanna egal Name (company, municipal€ty, HOA, utility, et eiton, III - Director of Public Works Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized s The legal en lndlvldual who will own this system is: Federalunicipailty © State/County 0 Private Partnership 0 Co i1d. 1401B th fd. Address NC State 1 h. 704-920-4200 Telephone r2. Project (Facility) Information: 2a. The Club at lnish Creek - Think Brief Pit ect N Contact Person: Robb Kink, Associate Name and Affiliation of So (704)333-0325 Phone Number 704-920-4244 Facsimile ete ndDesign, Inc. n 1g Kannapolis City 28081 Zip Code wmeltontci.kannapolis.nc.us E-mail 2b. Rowan Nag officials!) ation ❑ Other (specify): County Where Pro) s Located one Who Can Answer Questions About this Application 3c. rklauk landdesi t n.com E-mail Project Is New Modification (of an existing permit) on, Permit No.: If Modificati For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. ad'ding another phase, changing line size/length, etc.). Only Include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been includedin the original permit, 2. Owner is w4 Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: __ ... ._ sold, f 2b. If . _ d, facilities owned by a (must ch 0 Retaining Ownership (i.e. store, church, single office, etc.) on 0 Leasing units (lots, townhornes, etc. - skip to Item 6(3)) 0 Selling units (l,•ts, townhomes, etc. - go to Hem B(2b)) Water Sewer Authority of Ca)rrus County Owner o Q 4a. Rocky River Regional LL Z 5a. City of Kannappalls Name of WWTF Owner of Downstream rigin of this wastewater is (check a ( Residential Subdivision. © Apartments/Condominiums El Mobile Home Park 0 School El Restaurant El Office Wastewater TreatmentFacility (WWTF) Treating Waste ater Treatment Plant fib. iviing Sewer Size at apply):. [j Public Utility (Instruction III) © Homeowner Assoc./Developer (Instruction IV) er From This Project 4b. NC0036269� WWTF Permit No, 5c, j Car Wash (D institution 0 Hospital © Church © Nursing Home 0 Other (specify): Permit Number of Downstream Sewer 7. Volume of wastewater to be allocated for this particular project: n gallons per day 'Do not include previously permitted allocations If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted in subsequent permits that conn El Flow has already been allocated In Permit No. LI Rehabilitation or replacement of existing sewer with no new flow expected known DomesticlCommercial % Industrial % Other (specify): FTA 02/03 - Rev, 3 04/05 AST -TRAP" t PPLICAT ON for GEA ITY SEWERS, PUMP STATIONS, Af'4TD FORCE M.AI dS PAGE 4 w` 0 0 z Q LL. Z Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) S" 2,716 ENTER TOTAL LINE LENGTH IN MILES Summary of Pump Stations to be Permitted (attach additiona Location ID tosen - as shown on Design Flo plans for cos -reference) (MGD) 0.51 Operational Point GPM TDH Gravity or Force Main use the pull down menu) Gravity Power Reliability C (1- dual line feed; 2- permanent generator anr!ATS; 3- portable generator wltetemet9,;4-wet well storage) er system corn with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance Is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WM4 YOUR APPLICATION Have the following permitsdcertlflcations been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? © Yes Ej No ►) N/A Sedimentation and Erosion Control Plan? ► Yes 0' No 0 N/A Stormwater? 0 Yes [l No ►:4 N/A 14, Does this project involve serial lines or siphons? These lines will be considered high priority and must be checked once every six me n FTA 02/0 Rev. 3 D1105 FAST-+T1tAC. APPLICATION for RAVITY S ;iVERS, Pt1l"�"IP ST'ATI NS, AND FORCE r"IAINS PAGE 5 row . Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as; necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: El A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map elf chosen - as shown on Name of map for cross reference) Waterbody County Yadkin Rowan la. River Basin Irish Buffalo body S Index Waterbody Classification 13-17-9-(1) WS-III CA Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant"s Certification: i, Wilmer Melton, Ill, Dir. Public Works, attest that this application for The Club at Irish Creek Trunk Sewer has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: in accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, o certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as civil penalties up to $25,000 per violation. Signing Official Signature Professional Engineer's Certification: a3-- 19? Date I attest that this application for The Club at Irish Creek Trunk Sewer has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statemen representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Raymond R. Waugh Professional Engineer Name 2b. LandDesign, Inc Engineering Firm 2c. 223 North Graham Street Mailing Address 2d. Charlotte City 2g. (704)333-0325 2h. (704) 376-8235 2i. 2e. NC Telephone Facsi 2f. 28202 Zip anddesirtn.co Sealure Da FTA 02f03 - Rev. 3 04/05 State of North Carolina Department of Environment and Natural Resources Division of Water Quality WATERSHED CLASSIFICATION ATTACHMENT Any changes made to this form will result in the application being returned. (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) INSTRUCTIONS: To determine the classification of the watershed(s) in which the subject project will be located, you are required to submit this form, with Items 1 through 8 completed, to the appropriate Division of Water Quality Regional Office Water Quality Supervisor (see Page 2 of 2) prior to submittal of the application for review. At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5-minute USGS Topographic Map that shows the surface waters immediately downslope of the project. You must identify the location of the project and the closest downslope surface waters (waters for which you are requesting the classification) on the submitted map copy. If the facility is located in the Neuse River Basin, also include a copy of the soil survey map for the project location. The corresponding non -discharge application may not be submitted until this form is completed by the appropriate regional office and included with the submittal. 1. Applicant's name (name of the municipality, corporation, individual, et .); 2. Name and complete address of applicant: LandDesign. Inc. 223 North Graham Street City: Charlotte State: NC Zip: 28202 Telephone number: (_704 ) 333-0325 Facsimile number: (704 ) 376-8235 3. Project name (name of the subdivision, facility or establishrnent, etc.): The Club at Irish Creek 4. County where project is located; Rowan 5. Name(s) of closest surface waters: Kannapolis Lake 6. River basin(s) in which the project is located: lrishBuffalo C 7. Topographic map name and date: E,,__,pochvilie, NC 1993 8. North Carolina Professional Engineer's seal, signature, and date: TO: REGIONAL OFFICE WATER QUALITY SUPERVISOR Please provide me with the classification(s) of the surface waters, watershed(s), and appropriate river basi these activities will occur, as identified on the attachedmp scgrnen: Name(s) of surface waters and river basin(s): Classification(s) (as established by the EMC): Proposed classification(s), if applicable: River basin buffer rules, if applicable: Signature of regional office personnel: Date: FORM: WSCA 10/99 Page 1 of 2 DIVISION OF WATER QUALITY REGIONAL OFFICES Asheville Regional Office WQ Supervisor 59 Woodfin Place Asheville, NC 28801 Phone: (828) 251-6208 Fax: (828) 251-6452 Avery Buncombe Burke Caldwell Cherokee Clay Graham Haywood Henderson Jackson Macon Madison McDowell Mitchell Polk Rutherford Swain Transylvania Yancey Raleigh Regional Office WQ Supervisor 3800 Barrett Drive, Suite 101 Raleigh, NC 27609 Phone: (919) 571-4700 Fax: (919) 571-4718 Chatham Durham Edgecombe Franklin Granville Halifax Johnston Lee Nash Northampton Orange Person Vance Wake Warren Wilson Winston-Salem Regional Office WQ Supervisor 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4600 Fax: (336) 771-4630 Alamance Alleghany Ashe Caswell Davidson Davie Forsyth Guilford Rockingham Randolph Stokes Surry Watauga Wilkes Yadkin Fayetteville Regional Office WQ Supervisor Wachovia Building, Suite 714 Fayetteville, NC 28301 Phone: (910) 486-1541 Fax: (910) 486-0707 Anson Moore Bladen Robeson Cumberland Richmond Hamett Sampson Hoke Scotland Montgomery Washington Regional Office WQ Supervisor 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 946-9215 Beaufort Jones Bertie Lenoir Camden. Martin Chowan Pamlico Craven Pasquotank Currituck Perquimans Dare Pitt Gates Tyrell Greene Washington Hertford Wayne Hyde Mooresville Regional Office WQ Supervisor 919 North Main Street Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Alexander Cabarrus Catawba Cleveland Gaston Iredell Lincoln Mecklenburg Rowan Stanly Union Wilmington Regional Office WQ Supervisor 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Phone: (910) 395-3900 Fax: (910) 350-2004 Brunswick Carteret Columbus Duplin New Hanover Onslow Pender FORM: WSCA 10/99 Page 2 of 2 ILE Primary highway, hard surface Secondary highway, hard surface ROAD CLASSIFICATION Light -duty road, hard or improved surface Interstate Route Unimproved road US. Route State Route EN©CHVILLE, N. C. N3530—W8037.5/7,5 1970 AMS 4855 11 SW —SERIES V842 Central Files: APS SWP V 04/30/07 Permit Number WQ0031659 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation sonja.basinger Permitted Flow 0 Facility Facility Name The Club at Irish Creek Trunk Sewer Location Address Owner Major/Minor Region Minor Mooresville County Rowan Facility Contact Affiliation Owner Name Owner Type City of Kannapolis Government - Municipal Owner Affiliation Melvin Rape, PE PO Box 1199 Kannapolis Dates/Events NC 280811199 Qrig Issue App Received 04/26/07 Draft Initiated Scheduled Issuance Public Notice Issue Regulated Activities Requested/Received Events Subdivision Additional information received Wastewater collection Additional information requested Outfall NULL Effective Expiration Waterbody Name Stream index Number Current Class Subbasin A N .N A. P O . S April 24, 2007 06501-71 NC Div of Environmental Management Department of Environment and Natural Resources — Division of Water Quality, 610 East Center Drive, Suite 301 Mooresville, North Carolina 28115 Re: Club at Irish Creek Trunk Sewer City of Kannapolis - C:'abarrus County Dear Sir or Madam: APR Please find attached for your review and approval the original and one copy of the permit application and a check for $400.00 for the processing fee for the above reference project, This extension is being permitted with no tloww=`. Flow wiG1 be permitted in subsequent permits that connect to this line. The Water and. Sewer Authority of Cabarrus County Standard Specifications for Wastewwrater Collections Systems were approved by your office and are being maintained by the Division of Environtnental Management. This project will be installed in accordance with these Standard Specifications. Please call me at 704-93-1519 if� Sincerely, Stephen J. Bissinger, PE Assistant. City. Engineer 06501-71 sewer per questions.