Loading...
HomeMy WebLinkAboutWQ0024177_Regional Office Historical File Pre 2018A:7;A NCDENR North Carolina Department of Environment and Natural Division of Water Quality Michael F. Easley, Governor August 4, 2004 Mr. David Treme, City Manager City of Salisbury Post Office Box 479 Salisbury, North Carolina 28145 Resources William G. Ross, Jr., Secretary Alan W. Klimek, P.E., Director Subject: Permit No. WQ0024177 City of Salisbury Airport Road Sanitary Sewer Extension Wastewater Collection System Extension Rowan County, North Carolina Dear Mr. Treme: In accordance with your application received on August 2, 2004, we are forwarding herewith Permit No. WQ0024177, dated August 4, 2004, to the City of Salisbury for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 North Main Street, Mooresville, North Carolina 28115 Phone: 704-663-1699 / Fax: 704-663-6040 / Internet: http://h2o.enr.state.nc.us One NorthCarolina /7aturall Mr. David Treme Page 2 August 4, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Salisbury for the construction and operation of approximately 191 linear feet of 8- inch gravity sewer to serve 33.60 acres of Industrial space and 70 employees as part of the Airport Road Sanitary Sewer Extension project, and the discharge of 102,550 gallons per day of collected domestic wastewater into the City of Salisbury's existing sewerage system, pursuant to the application received August 2, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Salisbury -Rowan WWTP (Grants Creek Treatment Train NPDES No. NC0023884) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Rowan County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0023884) Darryl Wagoner, Salisbury Engineering & Planning Water Quality Central Files NDPU Files NORTHCAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection .facilities shall be properly maintained and operated at all times. The Permitted shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by '15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with :this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the North Carolina Department of Environment and Natural Resources, Water Quality, 919 North Main Street, Mooresville, N.C. 28115. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate .corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicableriver buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following:. a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 4th day of August, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ,414 for Alan W. Klimel , P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024177 3 Fast Track Engineering Certification Permit No. W00024177 August 4, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storagegreater than longest past three .year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on' the record drawings or in written summary form: Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of'North Carolina, having been authorized to observe (E periodically, ❑ weekly, ❑ full time) the construction of .the Airport Road Sanitary Sewer Extension, Rowan County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC,2H .0200; the Division. of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 08/03/04 Permit Number WQ0024177 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Fast Tract. Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Individual Extensions Primary Reviewer Permit Contact Affiliation sonja.williams Permitted Flow 102550 Facility Facility Name Airport Road Sanitary Sewer Extension Location Address Owner MajorlMinor Region Minor Mooresville County Rowan Facility Contact Affiliation Owner Name Owner Type City of Salisbury Government - Municipal Owner Affiliation David Treme PO Box 479 Salisbury NC 28145 Dates/Events Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective 08/02/04 g D4_ Regulated Activities Requested/Received Events Expiration Commercial or industrial. other Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE AJNS PAGE 1 ,------------- - USE THE TAB KEY TO MOVEFROM FIELD TO FIELD! • __ Application Numbe.r. (to be (,--ornpleted by DWQ) \Ni. 042:224 - _ 1 11 1, Owners la- CitY_OfSatislaury._ F[ Legal Name (company, municipality, HOA, utility, etc. .• David W. Treme City Manager . „„.._ • Signing Official Name Etnd Title (Please review 15A NCAC 2H ,0206(b) for authorized .signing officials!) lc. The legal entity ii,Yho wiii ownthis system is 1,3 Ind.r.tidual E Federal Ei Municipality fl State/C,ounty 0 F 'yam Partnership E Corporatien L Other (spricty): 1d. _ 0 • Bp. 479 Street Address z 0 3-- 15 G71J4) 638 - Telephone O 2. Project (Facility) Information: State Salisbury City 1g- Z8145 Zip Code ._(._7_04.) 6_38_ 5 232. 1j, j_beha@ a 1..i_sbur_y Facsimile. E-mail 23.Airport Road Sanitary Sewer Ext. 25, CL Brief Project Name (permit will refer to this name) County Where Project •c....eted 3. Contact Person: B. PERMIT INFORMATION 3a-Darryl_aag ner, _Owner ....SEZ2 Nome and Affiliation of Someone Who Can Answer Questions About this Application 3b, (704)633-8550 3. seandp@aol.com Phone Niiinber E-mail 1. Project is Ej New rj Medificiation (of an existing perrnit) if Modification, Permit No..: 2. Owner is Public (skip to Item B(3)) 0 Private, (go lo Item 2(a)) • 2a. If private, applicant will be. 25. 5 sold, facilities owned by a (must, choose ohei). Retaining Ownership (i.e. store, church, .single office, etc.) Public Utility (Instruction III) Lit Leasing units (lots, townhome,s, etc. - skip to Item B(3)) 0 Homeowner AssociDeveloper (Instruction IV) 0 Selling units (lots, townhornes, etc. - go to Item B(2b)) 3. City of Salisbury Owner of Wastewater Treatment Facility (WWII') Treating Wastewater From This Project 4a, Salisbury Rowan WWTP, Grant Crk 4b. NC0023884 Name of VYWIF Train WWTF Pem-lit No. 5a City of Salisbury 5b. 8" 14 ,,c, Downstream Sewer Owner of Downstream Sewer Recetvina. Sewer Size ! Permit Num' 6. The origin of this wastewater is (check all that apply): 0 Residential Subdivision 0 Car Wash 0 Apartments/Condominiums Ej Institution LJ Mobile Home Park E Hospital Li 0 Church School • Restaurant 0 Nursing Home Eliofflce a Other (specify): warehouse industrial 7. Volume of wastewater to be permitted in this project: 1 02' 5ga512ns per day 6 0 % Domestic/Commercial 40 % Industrial % Other (specify): 8. If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line • Flow has already been allocated in Permit No. • Rehabilitation or replacement of existing sewer with no new flow expected . _ FTA 02/03 -TRACK APPLICAT VITA' SE`TI" RS, I"Ut 4P STA.TIONS,. AND FORCE l 'IAINS PACE 2 Provide the wastewater flow calculations used in dete rmining the permitted flow in accordance v,ith 15A NCAC 24-1 .02190) for item L;7) or the design flow for Line or pump. station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this a pp ication. Submit a separate request tc the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mast Service Center, Raleigh„ NC 27699-1617 in accordance ;with 15A. NCAC 2H .0219(1)(3). 33.60 Ac. Industrial area x 3000 GPD = 100,800 GPD 70 Employees x 25 GPD 1750 GPD 10. Summar,, of Sewer Lines to he Permitted (attach additional sheets if necessary Size (inches) 8 " Length (feet) Gravity or Force Main, (pull down menu) Gravity Gravity Gravity Gravity Gravity Gra ^4y Coa y ENTER TOTAL LONE LENGTH IN MILES Q • o4 11. Summary of Pump Stations to he Permitted (attach additional sheets as necessary) Power Reliability Option Location ID Design Flow Operational Point (dual fine feed, permanent generator, Q (as shown on plans) (MGD) GPM c, TDH portable generator, wet well storage) lL z 12, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?' J Yes LI No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS PR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13, Have the following permitslcertifications been submitted for approval? Wetland/Stream Crossings - General 'Permit or 401 Certification? Yes LI No ® N/A Sedimentation and Erosion Control Plan? ® Yes LI No © NIA Stormwater? [] Yes ( No [] NIA ETA 02/03 AST -TRACK RAi'I'f"1:" SEWERS, a t: P STATIONS, AND 1, Use the t7ivistcn'n earssJ nice document entitled, . (FAST -TRACK f t+"4rER SYSTEMS)" t,., confect ca necessary). This C .`Ut cnt i ul' office (see instructions f, NING STREAM CLASSfE(CATI©NS FC}t F=Gf,'vi FTA 02103 he stream `.M (attach h additional shin:. is as'' y contacting t + r ga€ar ,Cato DRision of. Vilater indicate tine following: A Watershed Classification is -di parts of the project are of least 100 feat away from any down slope. waterbody6 AND, A Watemhed Cla sifiC.zt[i. n nu!. needed because! f he ce ion Ct Location ID Name of \Naterbody Ccu;it,y io't d ponot en wet well storage as a power 'r.ferEacady Stream 1^.'nVr^"body River Fusin tndcx Cta= i�icati%r Site Grants Creek Rowan Yadkin 12-110 Submit the €6,5" x 11"topographic map as required in Instruction VI r 4ic,< tcun: attlzaaphd " Airport Rd. San. Sew. Ekts,heerareri o the. best of my, knowledge_ 1 understand that if all repaired pads of tlai 'purred supporting documentation ill/CI rtttrch?mnnt' are not included, this al pitcnlica heing returned as incumplcte. Noka: In accordance with North Carolina General Statutes 143-215, airy person whin knowingly makes any false nth mint, representatien, cr certification in any applica a Class 2 misdemeanor which Ird,9 inc udc a Mine. riGt (3 exceed $10,000 cis well as civil pen li e;.; up to n 25,0E+0per fr ifltton. n is provided!. Dale pplication fcr Airport Rd. S . S . E ta5 been reviewed by me and is accurate, comap/etrr sistent vvith the irira the ertc?rnc >iragpfuns„ calcuiritio'as end all other suppcding dncurnh.(aorion tea the ny knowfedge. 1 futl'lrex attr,st th2af tc� the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for (gravity Sewers adopted February 12, 1996, and the Minimum Design Grifenia for the Fast -Track Permitting of Pump Stations and Force Morns adopted June 1 > 1, 2000 and the watershed classification in accordance with Divmion guidance.. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signi5es that f have reviewed this material and have judged it to be consistent with the proposed deign. Note: In accordance with NC General Statutes 143-21.6.r1 and 143 2'1,5.6'B, any person who knowingly makes any false statcrrient,e representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $1.0,000 as well as civil penalties up to $25,000 per violation, 2a. T?.arry__L_ Iacronac r Professional Engineer Name 2b, Engineerin Fr 2c.._5m e Address 2d. City 2g. 704-633- Telephone Engineer. 1- t 7 0 4-633_8 5 5 Facsimile yC 2f, - 780�1 State Zip SEANDP@AO'L. com A t 12 • • (•3 -r AITA, NCDENR North Carolina Department of Environment and Natural Resources DIVISION OF WATER QUALITY Michael F. Easley, Governor William G. Ross, Jr., Secretary Alan W. Klimek, P.E., Director July 28, 2004 CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. David Treme, City Manager City of Salisbury Post Office Box 479 Salisbury, North Carolina 28145 Subject: Return of Permit Application Package Airport Road Sanitary Sewer Ext. project Wastewater Collection System Extension Rowan County, North Carolina Dear Mr. Treme: The Division of Water Quality's Mooresville Regional Office is unable to accept the enclosed application package (with fee) for review for the following reason: ✓ A North Carolina -licensed Professional Engineer did not sign, seal and date the Professional Engineer's Certification in item V of the application. Please be advised that any changes to the original application merit complete review and require new signatures, dates, and engineer stamp to demonstrate that a proper review has been conducted on the application resubmitted to the Division. Please note that the item listed above must be completed prior to resubmitting the permit application package (with fee) for approval. Your application is being returned as incomplete in accordance with 15A NCAC 2H .0208. The success of the fast -track approval process depends upon the receipt of complete and accurate applications. Please make the appropriate corrections and resubmit the application. The review process will then begin upon receipt of the completed application. Please be advised that construction and/or operation of wastewater collection system extension without a valid permit is a violation of North Carolina General Statute 143-215.1 and may subject the violator to appropriate enforcement actions in accordance with North Carolina General Statute 143- 215.6. Civil penalties of up to $25,000 per day per violation may be assessed for failure to secure a permit required by North Carolina General Statute 143-215.1. Mooresville Regional Office 919 North Main Street, Mooresville, North Carolina 28115 Phone: 704-663-16991 Fax: 704-663-6040 / Internet: h2o.enr.state.nc.us Nne orthCarolina Natural& Mr, David Treme Page 2 July 28, 2004 If you should have any questions regarding the acceptance of your application, please do not hesitate to contact me at (704) 663-1699. Thank you for your cooperation.. Sincerely, Sonja Williams Consultant Enclosures (application + check no. 370989) cc: Darryl Wagoner, Salisbury Engineering & Planning (no enclosures) MR0 FT Application File