Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0023958_Regional Office Historical File Pre 2018
OF \NATF90 Michael F. Easley, Govemor O G William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality June 1, 2004 Mr. David Treme, City Manager City of Salisbury Post Office Box 479 Salisbury, North Carolina 28144 Subject: Permit No. WQ0023958 City of Salisbury Boundary Street Sanitary Sewer Extension Wastewater Collection System Extension Rowan County, North Carolina Dear Mr. Treme: In accordance with your application received on May 13, 2004, we are forwarding herewith Permit No. WQ0023958, dated June 1, 2004, to the City of Salisbury for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Also note Permit Condition 12 regarding unknown development. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules: Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Internet httpl/h2o.enr.state.nc.us/ 919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040 ffr DENR Customer Service Center Telephone 1 877 623-6748 Mr. David Treme Page 2 June 1, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City. of Salisbury for the construction and operation of approximately 923 linear feet of 8- inch gravity sewer to serve 67.70 acres of industrial development as part of the Boundary Street Sanitary Sewer Extension project,, and the discharge of 203,100 gallons per day of collected domestic wastewater into the City of Salisbury's Salisbury -Rowan WWTP (Town Creek Treatment Train NPDES No. NC0023884) existing sewerage system, pursuant to the application received May 13, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan W. limek, P.E. cc: Rowan County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0023884) Darryl Wagoner, Salisbury Engineering & Planning Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions.and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system-widecollection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that .are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at !east once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Department of Environment and Natural Resources, Water Quality, 919 N. Main Street, Mooresville, NC 28115. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be' required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 11. Noncompliance Notification: The Pemiittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 12. Unknown Development: No flow in excess of the quantity permitted herein, 203,100 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Water Quality. Permit issued this the lst day of June, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klime, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023958 3 Fast Track Engineering Certification Permit No. WQ0023958 June 1, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer fines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in.a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (E periodically, ❑ weekly, ❑ full time) the construction of the Boundary Street Sanitary Sewer Extension, Rowan County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE WATER QUALITY 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. N for GRANr uSE THE TAB EL i TO MOVE FROM EU) TO F The f `ci'.l col r-t address. N.C. State th _._.(..7,P.4_),t Telephone 2. l r a (Facility 2_. I3on n ary St. Brie; ProSect Name} (i Person: 479 202 1rry.l 1 Nam .snd Aff l; lion ( 704) Phone` Number 2. Ovrrier It private, a NS, ANI) FORCE MAINS Application Number. 1NC�C` (to :x'3 co1 p^.cxttia i by DM)) r SE&P tyn ^>, O ut fionsl heu 8-8491 Sew. Ext. it Y.'Pii rete" to this mine) 550 Public (slip tmirming Ownership (i.e. store, c.Imr.rrett, single office, etc) ❑ Leas tscr (te t , towrshcines etc. - ...p to item Es(3)) .ts, townhomes, etc. -go fo Item k62b)) City Sa1 sbuiLy_.. Owner of Wastewater Treatment Facilil (t W 1 F) Treating, Wastewater from This Proj 2b. Rowan mty Where Prject is. Localad andp@aol . corn aV Perin ��. S Sy Rowan_.. W . _... .M...�s ur �r.�..__ Nettle of WWTF 0 5a_ City of Salisbury L 12"__.m. f Sewer Siz __Owner ofDownstream Sewer _ Receiving ew .....mm The origin of this wastewater is (check all that apply) El Residential Subdivision ElApartments/CondominiumsApartments/Condominius 0 Mobile Horne Park 0School Li Restaurant 0 Office SAY nstruction 1II) s c ve9rrper(Instruct%ert IV) 4b. NC0023884 WWIT Permit No, Permit Number of Downstream Sewer Car Wash ] Institution Hospital LI Church D Nursing Home Other (specify): Industrial 7 Volume of wastewater to be perrnit(r ci in this project 2 3"r igglydns per day If the permitted flow is zero, indicate whys 0 Interceptor Line - Flow will be permitted is subsequent perrnitz that, connect to thi Q Flow has already been ailo ted in Permit No, [ Rehabilitation or replacement of existing sewer with no new flow expected RECEIVED APB' % DornestiolComrnereial 00 % Industrial % Other (specify): 2004 A 111111111177 -TRACK APPLICATIONf�r GRAVITY SEWERS, PUMPSTATIONS, A D FORCE NE. PAGE 2 i_ . 9, Provide the wastewater flow la ci•Acutions used in determining tire permitted flow in accordance %Oh 15A NCAC °Ziti _0219(1) for Item B(7) or the design flow for lino ID I pump f,baton sizing if zero flow in the space. below., Values .oilier than i that in 15A NCAC 2t1 ,0219(!)(1-2) must be anpieNuii prior to submittal of this application, Submit a separate request to the Division of Water Quality, Nen-Dischaige Permitting Unit, 1617 Mail Service center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H „0219(i)(3). 67.70 Ac. x 3000 GPD/Ac. 10. Summary of Sewer Lines In be Permitted (attach additional si)ects if necessary) (inches) 8 1 1 z CD 0 Length (feet) 923' Ce12 0-4 Gravity or Force Main (pull down. menu) Gravity Gravity Gravity Gravity Gravity Gravity Gfavity Z ENTER TOTAL LINE LENGTH IN MILES 0 ri 11 11-0, CD . F- 1 1 ., summary of Pump Stations to be Pem-atted (attach additional sheets, as necessary) < Power Reliability Option Location ID Design Flow Operational Point (d.u.al line feed, permanent generator, 0 (as shown on plans) (MGD) GPM @ TDH portable generator, wet well storage) LL z cri 2. Does the sewer system °amply with the Minimum Design Galena toe the Fast Track Permitting of Pump Stations and Foree Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A. NCAC 2H _0200 as applicable? la:Yes No If no, please reference the, tierfinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted tor approval? Wetland/Stream Crossings - General Permit. or 401 Certification? D Yes Ei No NIA Sedimentation and Erosion Control Plan? ri Yes No N/A Stormwater? Ell Yes No N/A 1-1 A 02 plP.P. AST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS • PAGE 3 C. WATERSHED CLASSIFICATION 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ❑ A Watershed Classification is not needed because all parts of the project are at least 100 feel away from any down slope waterbody; AND. - _. _ ❑ A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID Name of on Map_ Waterbody Site Town Creek County Rowan Waterbody Stream Waterbody River Basin Index Classification Yadkin _. 12-115-3 C Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! D. CERTIFICATIONS 1. 1a. Applicant's Certification_ ! attest that this application for Boundary S t . San. Sew. has been reviewed by me and is accurate and complete to the best of my knowledge. -1 understand that if atl required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of 1 a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signing Official Signature Date 2. Professional Engineer's Certification: 1 attest that this application for Bondary S t . San- S evwas been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: in accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Darryl Wagrinsm.r Professional Engineer Name 2b. Sal i shTrry Engineering & Engineering Firm 2c. 516—A North Main -.Street Address 2d. _Sp 1 tsbury City 2g. 704-633-8552(1. 704-633-8550i. Telephone Facsimile Planning 2e. NC 2f. -281.44_ State Zip SEANDP@AOL.com E-mail a___suu+Nf► tt 7; a SEAL r; dm 9522 9 i .. G l iV ..• <3', lr( W Abo 1;%, 47 Seal. Signatrre 8(Date U Ll FtA 02/03 A NNAPOUS r2 MC kcD M. C KA NNAP M()DRESVIL L f- M ILLBFOOGF 7 Md. r-- 0 05/26/04 Permit Number WQ0023958 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Individual Extensions Primary Reviewer sonja.williams Permitted Flow 203100 Facility Permit Contact Affiliation Facility Name Boundary Street Sanitary Sewer Extension Location Address Owner Major/Minor Region Minor Mooresville County Rowan Facility Contact Affiliation Owner Name City of Salisbury Dates/Events Owner Type Government - Municipal Owner Affiliation David Treme PO Box 479 Salisbury NC 28145 Scheduled Orig Issue App Received Draft Initiated issuance Public Notice Issue Effective Expiration 05/13/04 WI/D 4- Regulated Activities Requested/Received Events Commercial or industrial, other Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin SALISBURY ENGINEERING A PLANNING 6 6-A NORTH MAIN STREET • SALISBURY, NC 28144 May 11, 2004 DENR Division of Water Quality 919 N, Main Street Mooresville, N. C. 28115 RE: Boundary Street Sanitary Sewer Extension Rowan County Dear Sir: ©ARRYL L, WAGONER, P.E. 704M633-855O MAY 1 14 Please find enclosed two applications for approval for the above referenced project. Please advise immediately if additional information is required. Enclosures DES riON `0�0F W A rfi9 —+ O Michael F. Easley, Governor Wiliam G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality January 22, 2008 David Theme, City Manager City of Salisbury P.O. Box 479 Salisbury, North Carolina 28145 SUBJECT: Boundary Street Sanitary Sewer Extension Permit No. WQ0023958 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on December 12, 2007. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not receiveda copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from http://h2o.enr.state.nc.us/ndpu/ndouapps.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sincerely, brtiai tRobert Krebs Surface Water Protection Regional Supervisor Enclosure Cc: Darryl Wagoner, Salisbury Engineering & Planning Surface Water Protection Section Central Files (certification page only) NorthCarol na Naturally Pretreatment, Emergency Response and Colledion Systems Unit Internet http:Uh2o.enr.nc.state.uslndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper Fast Track Engineering Certification Permit No. WQ0023958 June 1, 2004 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changestasultnq in non-compliance with this permit, regulations or minimum desiqn criteria. This project shall not be cortsidereci complete nor allowed to operate until this Engineer's Certifiction ittind all required supporting documentation have been recelied by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe periodicaIIy, El weekly, El full time) the construction of the Boundary Street Sanitary Sewer Extension, Rowan County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE WATER QUALITY 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. SALISBURY ENGINEERING Eic PLANNING 516-A NORTH MAIN STREET • SALISBURY, NC 28144 DARRYL L. WAGONER, RE, 704-633-8550 December 7, 2007 Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, NC 28115 RE: Boundary Street Sanitary Sewer Extension WQ0023958 Rowan County Dear Sir or Madam: I have enclosed record drawings and an Engineer's certification for the referenced project. All work is complete and has been installed in substantial compliance with the approved plans. Please contact me if you need additional information on this project. Sincerely, Enclosures EC NC DENR MR0 urface Water Protection