Loading...
HomeMy WebLinkAboutSW3191101_Application Form_20211025 (3)SHIELD October 14, 2021 Mr. Jim Farkas, Environmental Engineer DEMLR Stormwater Program 1612 MSC Raleigh, NC 27699-11612 Via email: Jim.Farkas@ncdenr.gov Subject: ArchCo Residential Cambridge Commons Apartments Denver, North Carolina Shield Project No. 1200195-01 Detailed Dewatering Summary Dear Jim, Shield Engineering, Inc. (Shield) is pleased to provide this explanation of the construction dewatering activities at the ArchCo Residential site in Denver, North Carolina. Robert Griffin, P.E., with Shield, visited the site Tuesday October 12, 2021, to inspect the dewatering piping. Due the nature of the soils, the Cambridge Project required evaluation of both the soils and the moisture content of those soils. In one area of the project, expansive clays, that retain moisture, and perched water created issues for construction of foundations and other aspects of the project. Shield provided geotechnical evaluation of the soils and groundwater elevations in order to assist with constructability of the project. After a significant dewatering evaluation of the area around Building 7 and the associated parking area for that building, Shield designed a temporary dewatering system to allow for construction of the building foundations and parking. This temporary system was designed with dewatering wells to temporarily lower groundwater that was perched above the clay layer. This system utilized pumps, tanks, and recirculated water to create a venturi effect and "vacuum" water from the wells. The system was installed and operated for approximately 2 - 3 weeks. The system has subsequently been totally dismantled and removed from the site. There is a stormwater BMP pond onsite designed to mitigate the effects of the parking and structures during rain events. (See Bohler Engineering design drawings for the Stormwater Control Measure/BMP for the site.) 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 ArchCo Residential October 14, 2021 Shield Project No. 1200195-01 Page 2 A system of permanent passive dewatering, French drain, systems was installed sub slab to assist in the removal of potential groundwater that may be in the vicinity of the floor slab. This design incorporates shallow trenches with perforated pipe and stone 3 to 4 feet below the floor slab. See the attached Shield drawings for design details of each building and the under -drain system. The permanent building passive drains for Buildings 5 and 6 are directed to a stormwater collection pipe that does not pass through the designed pond and would therefore have NO impact on the pond or the design loading. During inspection there was no flow coming from the passive dewatering systems under Buildings 5 and 6. Please reference the attached photo log for pictures of the piping connected to Buildings 5 and 6. Building 7 and the adjacent parking were also constructed with passive permanent drainage. The drains from these two areas were piped to the stormwater collection system that is connected to the Stormwater Management (BMP) Pond onsite. These are again shallow French drain systems that are design to allow the upper 2 feet of soil to remain dry enough to reduce "pumping" in the parking area and reduce sub slab moisture in the building. During my inspection, there was no flow coming from either of these systems. Please reference to attached photo log for pictures of the pipes from the parking lot and building underdrain system with zero flow. Based on an evaluation of the onsite BMP, there were no adverse effects from with the temporary dewatering during construction or from the permanent passive systems that were constructed under the building slabs. If there are any questions or for further discussion, please feel free to contact me at any time. Sincerely, Shield Engineering, Inc. !\�ieaa"tCtii�,=,® ®� Egg/® • SEAL fir•`'( Robert L. Griffin, P.E. = 036297` Principal Engineer dGIN Q,e• t t IGO/000 ���\\\ SHIELD ENGINEERING ArchCo Residential Shield Project No. 1200195-01 October 14, 2021 Page 3 Photo 1 - Pipe from passive sub slab dewatering, French Drain, from Building 5 and 6. No Flow. SHIELD ENGINEERING ArchCo Residential Shield Project No. 1200195-01 October 14, 2021 Page 4 Photo 2 - Pipe from passive drainage dewatering under parking lot beside Building 7. SHIELD ENGINEERING ArchCo Residential Shield Project No. 1200195-01 October 14, 2021 Page 5 f1' 1� Photo 3 - Pipe from sub slab drainage from Building 7, showing no flow. SHIELD ENGINEERING TRENCH WIDTH PLAN VIEW 24 SECOND/ ORIF GRADE WET POND 2 CLASS 1 RIP -RAP SPILLWAY DETAIL NTS TRENCH WIDTH 1 / ANTI -SEEP COLLAR. CLASS B CONCRETE OR COMPACTED CLAY WITH INFILTRATION RATE OF 0.01 INCHES PER HOUR OR LESS. SECTION A -A ANTI -SEEP COLLAR NTS FRONT VIEW -RASH RACK TO OUTLET ZOL STRUCTURE WITH SO CAGE CAN BE LIFTED AINTENANCE 3"X3" OPENINGS SECONDARY ORIFICE TRASH RACK NOT TO SCALE FABRICATED ALUMINUM BAR GRATE TRASH RACK WITH 5"X5" OPENINGS 24"x8" SECONDARY ORIFICE ELEV = 778.30' 4'X4' (INT. DIMS) OUTLET CONTROLSTRUCTURE 6" PVC DRAWDOWN ASSEMBLY WITH 2.0" WATER QUALITY ORIFICE ELEV. = 777.00' 5'X5'X2' CONCRETE BALLAST PAD (INCLUDING PRECAST BOX WALLS AND BOTTOM SLAB, FILL BOTTOM OF STRUCTURE WITH CONCRETE AND PROVIDE SMOOTH FINISH AT INVERT OF STRUCTURE) BOTTOM OF 14zOA , IV a • ; PROP RETAINING WALL (BY OTH G 783.13 I tl / /'�� IDE •.II°C e / ,'/ /'/ / G 783.20 / ^ ..n eG 782.95 IESZ i N , //�/ _-- ' G783.00 PATIO DP RAGE WITH 4 f I \ / J .•..' ,'/ ; ,�' � ,� G783.00 /' o CE , MAINTENANCqCy I 4 TORAGE SPAC G782.67 I ).751 CONTRACTOR TO VERIFY LOCATION 782.67 1 i • /' \� O / G 782.46 /'/ G 782.33 G 782.51 ' G 783.15 O - OF EXISTING UTILITIES BEFORE / G 782.46 BW 78249 / o BEGINNING POND IMPROVEMENTS. / EXISTINGSTORMWATER G782.53 T 83.96 ' G 782.06 `. �. ; < •� �� Sapp _� -`'�. EASEMENT / ; - � G 779.39 -BUILT LIGHT POLE / G 782.33 PRO a /G 780AS .06 - l80 ---- _ �� - \ - LOCATION (TYP.) 782.26 % ---- G 780.10 r / • - •' c 782.19 � TYP. DPE w I , G 782.62 G 783.20 \\ 6:1 SAFETY SHELF ,''r '� : G 781.99 G 781.80 SHELF:776.5 p�/ , / COMP c781.a2 (� G781.64 I• I G 782.03 / ` • � / � / \ r r / / ` � ` � \' G 782.75 ' G 783.10 / �/.\.\� �`� G 781.77 ' AT TOP OF RISER STRUCTURE \ / 8" HDPE G 781.44 �0� j�.' ? \ REVISED EASEMENT LIMITS 7C � / / `\ \\ \�� \ `� ` \ �` G 782.88 `\ STM C PIPE � `• � - _ \ a \ PROP. YARD INLET HICK STRIPES AT V INTERVALS G 780.55- ' G 783.45 ❑ \\```�\\\�\ \ \ \\,I\ G782.46 G783.46 G783.00 CK RED STRIPE AT T DEPTH MARKER \ ---------------------------------- - - - - - - \ \ , li - - ----- - _ - AA I G 776.50 ❑❑ BUILDING 5 El ` , \ _-----------770- --- - - - - - - - - - - - - - _` -- ---- - - - _ - FFE TYPE 794.83 --- ------ ----- - - \ ` I - -- - - _ - - _ BW 783.50 _ BW 783.50 - 784.17 ` ---- ------ - I - - - - - - - --- PROP YARD INLET ' - _ ---- ------------ _----- _ - ---- ----- - -------- - .\ � � ., � INV OUT 76 . - ----- --- I - - -- 7y , ` 9 7 (30") ---` - - --------------- - / -- - 773 ---- TW=BW 783.08 300 SF RIM 782.86 - »------------- (28 UNITS) ------ _ l SEDIMENT DEPTH MARKER NOT TO SCALE SCREW TYPE PLUG 6" 6" PVC PIPE AND TEE PERMANENT POOL 12" PVC CAP WITH 2.0" ORIFICE DRILLED INTO BOTTOM CAP NOTES: 1. DRAW DOWN ASSEMBLY SHALL NOT BE INSTALLED UNTIL WET DETENTION BASIN IS STABILIZED. DRAWDOWN ASSEMBLY NOT TO SCALE TOP OF POND = 783.0' DRAINAGE STRUCTURE STEPS (NCDOT STD 840.66) INSIDE AND OUTSIDE OF --- STRUCTURE SPACED V VERTICALLY (TYP) TOP OF RISER = 780.50' SECONDARY ORIFICE TRASH RACK i PERMANENT POOL = 777.0' 24" 0-RING OUTLET CULVERT ELEV = 776.5' 6" PVC DRAWDOWN ASSEMBLY WITH 2.0" ORIFICE DRILLED IN CAP AT BOTTOM WET POND 2 OUTLET CONTROL STRUCTURE DETAIL NTS FABRICATED ALUMINUM BAR GRATE TRASH RACK WITH 5"X5" OPENINGS DARY CONTROL ORIFICE R QUALITY OUTLET CULVERT NTI-SEEP COLLARS. CT FILL UNDER PIPE OTECH REPORT. NOTES: SEE NCDOT SPECIFICATION SECTION 840 FOR OUTLET STRUCTURE BOX, GRATE, REINFORCING, ETC. ALL CONCRETE TO BE MIN. 4,000 PSI COMPRESSIVE STRENGTH. CONVERT HOLE USED WITH SKIMMER DURING EROSION CONTROL TO PERMANENT WATER QUALITY ORIFICE WITH WET POND WHERE POSSIBLE. IF NOT POSSIBLE, SEAL AND GROUT FILL HOLE USED FOR SKIMMER. - - -- ----- -- - - - - - - - - - / \�/ PROP RETAINING WALL - ' - (BY OTHERS) ----------------------- -- _ 778 77 ------ EXISTING STORMWATER -- T=BW783.00 7 ---------- -- EASEMENT c782.o0 `___-- G 784.26 781 � ------ -- 782 ---- -- - - - - --- ---- ----- -- - - ---- - (n------ \ TW784.20 _---'"- ----- -,-" __ G786.48 ------ �- _ _ - `\``\�. � -�__. _ - ------"" -' / 6:1 SAFETY SH G782.40 _ / __--- -"- u - G 784.97 G 783.45 ---- ----------- ---- - - ---- - _ - -- -------------------------- -- --- - - -- ---- --- 793 --- - - - -- -- -- - --- -- ' P MIDDLE OF SHELF: 776.5 `, -- _ _,; ----- ------ - ---- -- _ ' `-'--- JIB---- SURFACE AREA IN PERMANENT POOL =6,548 SQ. FT. ` c 7az.75 '-- ® ---" _ ____ ---- - 789 - - - - -- - ---- _ -` --- --�-__ _- ----7- - - __ G784.00 --- __---- ,-'- _________________ ---- ----- 790 ----------------------- --- ---- _- C 14 ----- -- L G 783.72 -- -----'"' O "-- -- -- - __ _ -- --- ---- --- --- ---- 792 ---- -- _ PROP 48" MH -- PRO 0" H 3 DPE�. \ P ----------- -' - -_ - _---" PROP YARD INLET --- --- -- _ -- ---- - -- INV IN 771.27 (30") 0 - - - \ LIUw z U U z F_ LIU w W Q ~ OJ H s0 H J ~ Q W W �I �f = Z O_ 0 H n z Q Q Q Z J O k a Q Ua� no (<Co Q CD CUD o Z Q Q Q Z Q JI oZ 0 u ot7, U �g z0 >o (3 LUzz>ll� O w wll� Q= z o_ w w F- F-w = �w z Z 6 Z J Q O w Q Q C� 0 mU)zc)a5 o n/ wzU) ♦����♦ W m� �w> J (ACC U) o z Q w Co Z Co w Q a= a Q a 0 LL W W z = J Q m ~ C. O w CD �a � < U) 0 0 LL Cna aJ Cn D' go W ♦♦♦♦♦♦ i2 r �w LU U o� z 1' D_ a 0 w w w Lu om �w Li> Lu wZQZ�z zo Z Z Q >- W LIU W 0 Dwwz o I.Q I. n � U H ZmZZCIDD - Z U) Q� REVISIONS REV DATE COMMENT BY 1 2/12/20 2ND SUB BUILDING PERMIT SF 2 3/4/20 TRC SUBMITTAL SF 3 3/18/20 DUKE LANDSCAPING UPDATES SF 4 4/13/20 NCDEQ COMMENTS SF 5 7/12/20 IFC SF 6 8/17/20 IFC SF -\- - C-12 '',-'' --" INV OUT 771.27 (30) - - 790 _---- _ INV IN 770.75 (30") -- BTM OF POND: 773.0 PROP 48" MH `` - -- _____ INV OUT 770.75 (30") BTM OF SEDIMENT STORAGE: 772.0 _ R��89'72 �' ; APPROVED FOR INV IN 769.94 (30") -- -''---------- RIM 783.45 - _ � INV OUT 769.94 (30") BTM OF POND:770.0 __- / CONSTRUCTION RIM 787.68 BTM OF SEDIMENT STORAGE: 769.0 `\---------- ' r / _--'' - ----- PROJECT No.: 21591 `---------------'' ,, DRAWN BY: TGH PROP. RETAINING WALL BY OTHERS) i CHECKED BY. - - CHECK APL ------------ DATE: ---- I r ------ ------------------------ 08/27/19 -- --- / -- AS NOTED ------ - --- ------- -- CAD I.D.: - SWO - ----------------------"" , 6' WIDE, 6:1 VEGETATED SHE - ---------- --------------------------------------------------------------------------- CONCRETE SUPPLY COMPA \�421, PG 588 ' 4 _ PARCEL# 0052 ------- I TOP OF POND = z z - w � w 3:1 SLOPES ABOVE PERMANENT POOL SLOPES ABOVE VEGETATED SHELF ¢O " 0 �3:1 co LU o TOP OF RISER STRUCTURE = 780.50' SEDIMENT DEPTH o o MARKER v 100-YR STORM ELEV = 781.09 25-YR STORM ELEV = 780.84' y 10-YR STORM ELEV = 780.49 _ L 2-YR STORM ELEV = 779.22' v TEMPORARY POOL (WQV) = 778.30' y PERMANENT POOL = 777.9 INFLOW PIPE INVERT = 774.55' (B10) 2:1 SLOPES UNDER PERMANENT POOL BOTTOM FOREBAY r 773.0' BOTTOM SEDIMENT STORAGE ENTRANCE= 771.5' BOTTOM SEDIMENT STORAGE FOREBAY EXIT = TOP OF FOREBAY BERM = 777.0' 6' WIDE, 6:1 VEGETATED SHELF TOP OF SHELF: 777.0 BOTTOM OF SHELF: 776.0 REB Y (TYP OFB TH) PUMP TO DRAIN IF NECESSARY FOR POND MAINTENANCE BOTTOM POND = 770.0' SEDIMENT STORAGE = 769.0' EMERGENCY SPILLWAY ELEV = 780.75' LINED WITH 18" THICK CLASS A RIP -RAP 0-RING OUTFLOW CULVERT TO RIP -RAP DISCHARGE POINT 'COMPACT FILL UNDER OUTLET PIPE PER GEOTECHNICAL REPORT ANTI -SEEP COLLARS (REFER TO DETAIL ON SAME PAGE) 2:1 SLOPES UNDER PERMANENT POOL 30 15 7.5 0 30 1 "= 30' GENERAL NOTES: 1. BOTTOM OF POND AND BOTTOM OF FOREBAY GRADES SHOWN IN PLAN VIEW DO NOT REFLECT SEDIMENT STORAGE ELEVATIONS CONTOURS. PROJECT: CAMBRIDGE VILLAGE MULTIFAMILY FOR NORTH PILOT KNOB ROAD, LLC LOCATION OF SITE CAMBRIDGE VILLAGE 307 PILOT KNOB RD DENVER, NC 28037 LINCOLN COUNTY TD D ENGINEERING NC, PLLC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@BohlerEng.com \\\I111III// CAR SEAL - 047366 O ;-A 161° R ° F A RMP. SHEET TITLE: WET POND DETAILS SHEET NUMBER: C-912 \\BOHLERENG.NET\SHARES\FL-PROJECTS\2019\FLB190107\DRAWINGS\PLAN SETS\NCC172159 - SWO.DWG PRINTED BY: SFARMARTINO 8.18.20 @ 3:46 PM LAST SAVED BY: SFARMARTINO WET POND 2 CROSS SECTION NTS (10:1 VERTICAL EXAGGERATION) AFTER STABILIZATION BUT PRIOR TO PAVING, POND TO BE DREDGED AND CONVERTED FROM SKIMMER SEDIMENT BASIN TO PERMANENT WET POND. O 0 w 2 a w w a a) ch a W � N r U K Z 11 �0 0 oQ V U 6 a F D m U) Q C W _ O N O 0 O No w z m � W O C-14 DESCRIPTION LENGTH SLOPE UPPER INV. LOWER INV. PIPE MAT'L " r cow Co 0 RIM-789.72' IN-771.27' NORTH TRENCH *146 1.00% *777.7 *776.2 6" PERFORATED PVC � o � o Z LL yo = L 0 w o BUILDING 5 OUT-771.27' SOUTH TRENCH *146 1.00% *777.7 *776.2 6" PERFORATED PVC SHEET TITLE: TYPE 334 NOTE: to STORM STIR*81.3 2.00% *776.2 *774.6 6" SOLID PVC FFE = 794.83 TIE PLAN VIEW FFE = 784.17 INTO EXISTING NOTE: 0 10 20 40 BUILDING 5 STORM DRAIN, ELEVATIONS ARE BASED ON FF ELEVATIONS OF EACH BUILDING AS SHOWN ON THIS DRAWING. ALL 10,300 SF DESIGNED BY *DIMENSIONS AND *ELEVATIONS ARE SUBJECT TO CHANGE BASED ON EXISTING FIELD CONDITIONS. MINIMUM SLOPE SHEET: (28 UNITS) OTHERS ON ALL PIPES = 1.00%. (IN FEET) 1 "=20' O 0 N 2 a` 'a> C w w Y .0 a a) ch Z) a BUILDING 6 TYPE 334 FFE = 795.33 FFE = 784.67 10,300 SF (28 UNITS) ST 1S Eo so w B-60(4) B-70(5) B-80(6) RIM-783.12' RIM-783.04' RIM-783.25' IN-775.81' OUT-775.81' IN-776.30' OUT-776.30' IN-776.71' OUT-776.71' � a v r v'd I e' 1 % SLOPE PERMANENT DEWATERING 6' PERFORATED TRENCHES_ SEE CROSS-SECTION SOLID PVC DETAIL - SHEET 4 @ 10.75% �I DESCRIPTION LENGTH SLOPE UPPER INV. LOWER/NV. PIPE MAT'L NORTH TRENCH *148 1.00% *778.2 *776.7 6" PERFORATED PVC SOUTH TRENCH *148 1.00% *778.2 *776.7 6" PERFORATED PVC to STORM STR *37.2 8.60% *776.7 773.5 6" SOLID PVC NOTE: ELEVATIONS ARE BASED ON FF ELEVATIONS OF EACH BUILDING AS SHOWN ON THIS DRAWING. ALL *DIMENSIONS AND *ELEVATIONS ARE SUBJECT TO CHANGE BASED ON EXISTING FIELD CONDITIONS. MINIMUM SLOPE ON ALL PIPES = 1.00%. A A -o � z � W� �j w z z �w o Q 0 w� N W � N U r 11 K Z 00 �uu U oQ V U � Al.,� �a _ Q -6 W O Ul L U N m a y — Z v 3 _ T o U 4 i O N O- L - � N � � NN Q O .O N O S 6I U (na Z o o U 41 w° O 2 2 M �m QID �o aY0 w 0 J m oaw Ugh m Ir U 111 z H U O W W ZLU 7 U F M 0 w a o U 3 a J D m Un Q O W O N 0 O O N w 0 J Ir W Ir W Q m > 0 Z r W m ii F z m g o U Z 7 y Z W Q Q W W Q F 0 0 E U UU 0 SHEET TITLE PLAN VIEW 0 10 20 40 BUILDING 6 SHEET: (IN FEET) 2 1 "=20' � N � moo dO1S z_ a � B-130 S I1�I 1II W &RIM-783.22' B-90 IN-779.20' RIM-783.74' OUT-779.20' IN-777.15' T �w�oOUT-777.15' NVA n p IO a STOP I - I� IO E m I aWo��=0, I I nnllI L--d 11 1 °o°o a d woUa) �;n - wO O, O wEwEa.i 0 — o t ® �1a8.6'-6" • PVC 4k RI ��SOLID 6' 10y .% 1.07%SLOPE 19.9'-6" W.mw — — — — — — — — — — — — — — — — — — PERMANENT ---------- OF a WYa 6' 1.022FDEWATERING . 1 % SLOPE PERFORATED TRENCHES OMFC 2.4' I -- — — — — — — — — —-------- Th° Q' a SEE CROSS-SECTION I I I W O DETAIL - SHEET 4 j 1 mo o? q I� I 010 � I 1 wol ° m x J I� I h DaZ Uxh IO �I 11J mFY �U� Ir W (n I z ¢ow 2 a I�— Uz2 a o " w z m Im �l 0 W ml & a o U I SEE CROSS-SECTION 3 a DETAIL - SHEET 6 ca O O N 0 O O N oo O C7 — w N J ar W W Q m > 0 Z r WD [p II F 0 m o = U Z Z 7 Z Y W Q Q W W Q F fr f J = U Q 0 0 E U (n 0 BUILDING 7 SHEET TITLE: TYPE 234 FFE = 785.17 PLAN VIEW 0 10 20 40 BUILDING 7 FFE = 795.83 NOTE: ELEVATIONS ARE BASED ON FF ELEVATIONS OF EACH BUILDING AS SHOWN ON THIS DRAWING. ALL 9,250 SF *DIMENSIONS AND *ELEVATIONS ARE SUBJECT TO CHANGE BASED ON EXISTING FIELD CONDITIONS. MINIMUM SLOPE (28 SHEET: UNITS) ON ALL PIPES = 1.00%. (IN FEET) 3 1 "=20' DESCRIPTION LENGTH SLOPE UPPER INV. LOWER INV. PIPE MAT'L NORTH TRENCH *122 1.07% *778.7 *777.4 6" PERFORATED PVC SOUTH TRENCH *131.2 1.00% *778.7 *777.4 6" PERFORATED PVC to STORM STR *18.6 1.00% *777.4 *777.2 6" SOLID PVC a O�1 L[) O t/1 2 C (D c w 2 co 6 Y 0 Z) Al EAST LOT NOTE: ELEVATIONS ARE BASED ON FF ELEVATIONS OF THE EAST LOT AS SHOWN ON THIS DRAWING. ALL *DIMENSIONS AND *ELEVATIONS ARE SUBJECT TO CHANGE BASED ON EXISTING FIELD CONDITIONS. MINIMUM SLOPE ON ALL PIPES = 1.00%. I W PERMANENT DEWATERING ORATED TRENCHES E I 0 10 20 40 (IN FEET) 1 "=20' W � N r U 11 �0 0 oQ M = V U 6 a F m U) Q O W O N 0 O O N Z °O J w =ir O W m w m w p F Z U' m 2 0 Q O Z Z D Y z w w w ¢ w 0 0 E U (U 0 SHEET TITLE PLAN VIEW EAST PARKING LOT SHEET: 5