WQ0040038_Regional Office Historical File Pre 2018
FILE Water Resources Environmental Quality ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director June 20, 2018 Mr. Darren Lucas, Member/Manager Steele Creek Rivergate Apartments, LLC 3010 High Pine Church Road Asheboro, NC 27205 Subject: Permit No. WQ0040038 Steele Creek Rivergate Apartments, LLC Steele Creek Multi Family Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. Lucas: In accordance with your application received June 1, 2018 and additional information received June 20, 2018, we are forwarding herewith Permit No. WQ0040038 dated June 20, 2018, to Steele Creek Rivergate Apartments, LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition In: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. it shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1501 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. `' outing Comsares. State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue, Suite 301 [ Mooresville. North Carolina 28115 704-663-1699 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. Sincerely, 1.-40.CDocuSigned by: "1" '5.4:it.- MI- 1 45949E225C9464,. For by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Jeremy Icard, P.E. (e-copy) Charlotte Water (e-copy) Tommy Rowland (e-copy) Regional Office Files Water Resources Central Files PERCS (e-copy) 2 For NI-IZ Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Steele Creek Rivergate Apartments, LLC Mecklenburg County for the construction and operation of approximately 1,265 linear feet of 6-inch gravity sewer as part of the Steele Creek Multi Family project, and the discharge of 56,855 gallons per day of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received June 1, 2018 and additional information received June 20, 2018, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. DocuSiiggned by. / E-0A. 14SB49E225C94E&.. by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0040038 Permit Issued: June 20, 2018 SUPPLEMENT TO PERMIT COVER SHEET Steele Creek Rivergate Apartments, LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Plant in accordance with Permit Number NC0024970, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable„ unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shalt be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below, SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 56,855 gallons per day, shall be made tributary to the subject sewer system until an application For permit modification for an increase in flow has been submitted to and approved by the Division. 115A NCAC 02T.0304(b)] 2. This permit shall become voidable unless the agreement between Steele Creek Rivergate Apartments, LLC and Charlotte Water for the collection and final treatment of wastewater is in full force and effect, [15A NCAC 02T.0304(h)] The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes §143-215.6A to §143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. f15A NCAC 02T.01151 ll. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other 4 supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 115A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12,,1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Prograrn shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows, i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility, j. Documentation shall be kept for Subparagraphs (a) through (i) af this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6, Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 115A NCAC 02T.0108(b)] 7, Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. 6 A complete certification is one where the form is fully executed and the supporting documents are - provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or, greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design. Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 115A NCAC 02T .0116] . 8. Gravity sewers installed greaterthan ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)1 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Steele Creek Rivergate Apartments, LLC PERMIT #: WQ0040038 PROJECT: Steele Creek Multi Family ISSUE DATE: June 20, 2018 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION 1, , as a duly registered Professional En sneer in the State of North Carolina, having been authorized to observe (❑ periodically, n weekly, I full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final n Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office' 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 STATE OF NORTH CAROLINA COUNTY OF Mecklenburg Permit No. W 0 001 Da 3 S HOME/PROPERTY OWNERS' OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this • 1)C) day of 3 UST€ O-E t , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Steele Creek Rivergate Apartments, LLC , a non-profit corporation organized and existing under and by virtue of the laws of the State of North Carolina, hereinafter known as the ASSOCIATION. WITNESSETH: I. The ASSOCIATION was formed for the purpose, among others, of handling the property, affairs and business of the development known as Steele Creek Rivergate Apartments (hereinafter the Development); of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System); and of collecting dues and assessment to provide funds for such operation, maintenance, re -construction and repair. 2. The ASSOCIATION desires, to construct and/or operate a Disposal System to provide sanitary sewage disposal to serve the Development on said lands. 3. The ASSOCIATION has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and/or operate the Disposal System. 4. The Development was created subject to unit ownership in the dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. • NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and ASSOCIATION do hereby mutually agree as follows: 1. The ASSOCIATION shall construct the Disposal System and/or make any additions or modifications to the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2 The ASSOCIATION shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures bythe Association except for Federal, State, and local taxes and insurance. FORM: HOA 11-17 Page 1 of 2 3. The ASSOCIATION -shall provide in the:° Declarationand°Association .:Bylaws that the -Disposal ' System will be maintainedout ofttie"cammon oxpenses:°'ln order to assure that there shall be funds'readily available to repair, maintain, or construct the Disposal System' beyond the routine operation and maintenance expenses: the Declaration end Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance fluid allocated for the facility and shall be part of the yearlybudget. ' In the event the common:, expense allocation and separate fund(s) are not. adequate for the. construction, repair, and maintenance rofthe Disposal System, the Declaration ands Association Bylaws shall.provide for special, •assessments to°;cover such necessary .costs. There shall be no limit on the, amount of such assessments,and the Declaration and Bylaws Shall be provided such, that special assessments can be made as necessary at anytime. 5 If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village. county, water and sewer authorities, or other Unit of government shall hereinafter become available to serve the Development, the ASSOCIATION shall take such action as is necessary to cause the existing and future wastewater of the Development to be -accepted and discharged into said governmental, system, and shall Convey Or transfer as much of the Disposal;System and such necessary easementsas the governmental emit niayrequire as.conditlon:of accepting the. Development's wastewater. Recognizing .that it would be contrary to the public interest and to the public health, safety and welfare for the ASSOCIATION to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the ASSOCIATION shall provide in the ASSOCIATION Bylawsthat the.ASSOCIATION shall not eater into voluntary dissolution without first having,transferred its said system and facilities to some person, corporation or other entity acceptable'te and approved :by the COMMISSION' bythe issuance of a permit. • The-&SSOCIATIQN shall not :transfer, convey, assign or otherwise:relinquish or release: its .responsibility for the. operation' and maintenanceof its Disposal System' until a. permit has been reissued to the FOR`[ - ENVIFLONWNTAL MANAOEMBN MMISiON retinda Culpepper Interim Director, Division of Water Resourees ASSOCIATION'S successor:. 'lie .agreements set forth innumbered paragraphs3; 4, 5, 6, and 7 above shall be conditions of any . permit issued by the COMMISSION to the ASSOCIATION for -.the construction, maintenance; repair and operation, of t:he.Disposat Systent Acopy • of this agreement shall be filed' at the -Register of Deeds in the County(es) where the Declaration is filed and in the offices ofthe Secretary of Stateof North Carolina with-tbe, Articles ofincorporation of the Association, IN WITNESS WHEREOF, this,agreement was executed.in duplicate: origi als;by the duly authorized representative of the parties hereto on the: day and yeac,writtea as�indicated:by:each•ofthe parties named below: Steele :Creek` Rivet gate Apartments. LLC Nanie ofASSOCIATEON (Signattire), :,barer. Lucas Member/Manager ,Print Natireland.Title FORM. HOA 1147, 7 (Date) ) Page•2 oft CO � DIvIt ion of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources i 5A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: % 0'38(to be completed by DWR) All items must be completed or the application will be returned APPLICANT INFORMATION: 1. Applicant's name: Steele CreekRivergate Apartments, LLC (Darren Lucas) (company, municipality, HOA, utility, etc.) 2. Applicant type: U Individual [� Federal Corporation El General Partnership 11 Privately -Owned Public Utility ID State/County E Municipal 3. Signature authority's name: Darren Lucas per 15A NCAC 02T ,0106(b) Title: Member/Manager 4. Applicant's mailing address: 3010 High Pine Church Rd. City: (Asheboro State: NC Zip: 27205- 5. Applicant's contact information: Phone number: (336) 669-7683 Email Address: Darren Lueas(cc:yahoo.com Other RECEIVED/NC:DEN WOE tM4 MOO,ERERV LLE REMNAL.O II. PROJECT INFORMATION: 1. Project name: Steele Creek Multi Family 2. Application/Project status: © Proposed (New Permit) LI Existing Perrnit/Preject If a modification, provide the existing permit number; WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number; WQ00 3. County where project is located: Mecklenburg 4, Approxitnate Coordinates (Decimal Degrees): Latitude; 35.098' Longitude:-80.991 ° 5. Parcel ID (if applicable): 219-06-117 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jeremy Icard License Number: 026491 Firm: LandDesign Inc. Mailing address: 223 N. Graham Street City: Charlotte State: NC Zip: 28202- Phone number: (704) 333-0325 Email Address: jicard{clanddesign.com IV. WASTEWATER TREATMENT FACILITY (WWI INFORMATION: 1. Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek Permit Number; NC0024970, NC0024945, NC0024937 Owner Name: charlotte Water V. RECEIVING DOWNS I`REAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection. System. Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. 'GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? El Yes ENo N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement 'OR 4; DIM been attached? Yes N/A Association, has an Operational Agreement (FORM: HOA) been attached? Z Yes ON° LJNIA 3, If t.h.e Applicant is a lioine/Prom 4. Origin. of wastewater (check all -t. El Residential Owned Residential Leased LIJ School / preschool / day care EJ Food and drink facilities El Businesses offices / factories at apply): L] Retail (stores, centers, malls) LI Retail with food preparation/service Medical / dental / veterinary facilities fl Church El Nursing Horne El Car Wash LI i Hotel and/or Motels El Swimming Pool /Clubhouse LI Swimming Pool/Filter Backwash El Other (Explain in Attachment) 5. Nature of wastewater 19Q % Domestic/Commercial Commercial % Industrial (jJjjC 021 „0103(20.1) there a Pretreatment Program in effect? LI Yes E No. 6. Has a flow reduction been approved under 15.A NCAC 02T .011.41(1)? El Yes LI No If ves, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01 WM) Appartment Daily Design Flow 3'1) 135 gal/Day No. of Units Flow 408 55,080 GPD Pool 10 gal/Day 165 1650 GPD Leasing Office 25 gal/Day gal/ 5 125 GPD GPD gal/ gal/ GPD GPD Total 56,855 GPI) a See 15A 'NCAC 02T .0114(b). (d). (e)( I) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public a.ceess facilities located near high public use areas; and residential property located south or east of the Atlantic 'Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T :0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T,01.14] Shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. 'Wastewater generated by project: 56,855 GPD (per 15A NCAC 02T .(1,114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: E Pump Station or Gravity Sewer whereflow will be permitted in subsequent permits that connect to this line [1] Flow has already been allocated in Permit Number: LI Rehabilitation or replacement of existing sewer with no new flow expected LI Other (Explain); FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) 6" Length (feet) 1,265 Material PVC Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria • Section II1 contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vldl. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: 3. Design flow of the pump station: millions gallons per day (firrn capacity) 4. Operational point(s) of the purnp(s): gallons per minute at 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) feet total dynamic head (TUH) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(I3) > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. To If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel tirneframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(t) & (g) > 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems; El Yes EJNo Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) Water mains (vertical -water over sewer including in benched trenches) Water mains (horizontal) Reclaimed water lines (vertical - reclaimed over sewer) Reclaimed water lines horizontal - reclaimed over sew **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class II impounded reservoirs used as a source of drinking water **Waters classified WS (except WS-I or WS-V), 13, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item,IX.2 **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches Any building foundation Any basement Top slope of embankment or cuts of 2 feet or more vertical height Drainage systems and interceptor drai Any swinuning pools Final earth grade (vertical) 24 inches 18 inches 10 feet 18 inches 2 feet 100 feet 50 feet 10 feet 5 feet 10 feet 10 feet 5 feet 10 feet 36 inches > 15A NCAC 021.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications vvebpage > If noncompliance with 02T.0305(f) or (g.), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) Z Yes El No ri N/A > See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? Yes El No NIA > This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404. Nationwide or individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 & Buffer Permitting Branch. Yes El No 5. Does project comply with 15A NCAC 02T,0105(c)(6) (additional permits/certifications)? Yes Ej No Per 15A NCAC 02T,0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes No E N/A > If yes, include an attachment with details for each line, including type (aerial fine, size, material, and location). High priority lines shall be inspected by the perrnittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATtrONS:. Does the submitted system comply with 15* NOW tit and Force Mainsiljtc v lots). and the (iu' itwy Sew Yes DNo appl -able? If No, complete and submit the Variance/Alternative Design Request application (VAD:)C 10-14) and supporting documents for review, Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. Professional Engineer's Certification: oteskional Enginee Application Item. III. attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plank specifications, engineering calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been prepared in accordance with. the applicable regulations, Gravity Sewer Minimum EDesiign Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria far the Fast -Track Permitting .of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE _. In accordance with General Statutes 143-21.5,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a (('lass 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC U2°1" .0106(b): I, Dec mmc ,.s ..__. -_ M (Signature Authority's name & title from A ccation Item 1.3.) attest that this application for has been reviewed by me and is accurate and complete to the best airily knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments. are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. twill make no claim against the Division of Water Resources should a condition of this permit be violated, I. also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 2 t A and 14 ,,.' l s F . an person lao knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signatur Dat FORM: FTA 04-16 Page .5 of 5 Divlslon of W41te`r Resources APPLICANT INFOI 1. Applicant's name: 2. Applicant type: State of North Carolina Department of Environmental Quality Division of Water Resources I SA NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-I6 & SUPPORTING DOCUMENTATION Application Number Nova completed by D Alt items must be completed or the application will be returned ATION: A Individual E Corporation WOPOS df arren I ucas) (company, municipality, IIOA, utility, etc.) ❑ General Partnership Ell Privately -Owned. Public Utility ❑ Federal 0 State/County ❑ Municipal 3, Signature authority's name: Darren Lucas per 1 C 02T . 106 Title: Member/Manager 4. Applicant's mailing address: 3010 High Pine Church Rd. City: Asheboro State: NC Zip: 27245- Applicant's contact information: Phone number: (336) 669-7683 Email Address: Darren_Lucas@yahoo.com IL PROJECT .INFORMATION: 1. Project name: Steele Creek Multi Family 2. Application/Project status: Proposed (New Permit) Other ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of.a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4, Approximate Coordinates (Decimal. Degrees): Latitude: 35,09$'Longitude:-80,991 5. Parcel ID (if applicable): 219-06-117 (or Parcel ID to closest downstream sewer) M. CONSULTANT INFORMATION: 1, Professional Engineer: deremv Icard License Number: 026491 Firm: LandDesi,• ' Inc, Mailing address: 223 N. Graham Steeel City: Charlotte State: Lc Zip: 28202- Phone number: (704) 333-0325 Email Address: licard c"!landdesitgn.com WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION; 1. Facility Name: McAlpine Creek, Irwin Creek. Sugar Creek Permit Number: NC00249 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I, PerrnitNumber(s): WQ Downstream (Receiving) Sewer Size: inch Sv tcrtt de °r lle otiltrtS stern Permit l urnbezt s! fif at talicab Owner'Name(s): WQCS C0024945, NC0024937 FORM: f"TA G)4-1.6 Page 1 of 5 VI. GENERAL REQUIREEMENTS 1, If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and. Necessity been attached? E Yes ❑No N/A. 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A If the Applicant is a .Ho rp of erty Owners Association, ltas at2(>t eraiionalA 4. Origin of wastewater: (check all that apply): ❑ Residential Owned Ij Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities LJ Businesses / offices / factories ® Yes ❑No ❑N/A ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home e: 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) >Is there a Pretreatment Program in effect? ❑ Ye 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? El Yes LI No A If yes, provide a copy of flow reduction approval letter 7, Summarize wastewater generated by project: Establishment Type (see 02T.0114 Appartment Pool Daily Design Flow ,b 135 gal/Day 10 gal/Day `FORM: HOA1 been attached? ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) No No. of Units 408 165 Flow 55,080 GPD 1650 GPD Leasing Office 25 gal/Day gal/ gal/ 125 GPD GPD GPD gal/ Total GPD 56,855 GPD a See JSANCAC 02T ,0114(b), (tl.),.(c)(1) and (e)(2). for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table '15A NCAC 02T,0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8, Wastewater generated by project: 56,855 GPD (per 15A NCACO21',01,14) A Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent pets that connect to this line © Flow has already been allocated in Permit Number: LJ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & 1, Summarize gravity sewer to be permitted.: Size (inches) 6' Length (feet) 1,265 )C ;ravits Material PVC A Section II & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria A Section 111 contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIM PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the purnp(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): El Standby power source or pump with automatic activation and telemetry, - 15A NCAC 02T .0305(h)(l)(B): • Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ▪ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: Portable power source with manual activation, quick -connection receptacle and telemetry I5A NCAC 02T .0305(h)(1)(C) or El Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): A It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 DC. • SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .030 (f) : I. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (0 • 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer s stems: Yes El No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) Water mains (vertical -water over sewer including in benched trenches) Water mains (horizontal) Reclaimed water lines - reclaimed over sewer) Reciairned water lines (horizontal - reclaimed over sewer) 24 inches 18 inches 10 feet 18 inches 2 feet **Any private or public water supply source, including any wells, WS-1 of Class I or Class II impounded reservoirs used as a source ofdrinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item 1X.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches Any building foundation Any basement Top slope of emb 10 feet 5 e t 10 feet ent or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools Final earth grade (vertical) 10 feet 36 inches 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(t) cannot be achieved. • **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage If noncompliance with 02T.0305(f) or igh see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) El Yes LI No El N/A 9 See the Division's draft separation requirements for situations where separation cannot be meet 9 No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? E Yes E No [1:1 N/A This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? Information can be obtained from the 401 & Buffer Permitting Branch El Yes IIjNo 5. Does project comply with 15A NCAC 02T.0 5 c 6) (additional permits/certifications)? Yes El No Per I5A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc,). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, liigh-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes Ej No N/A 9 If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the perinittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. - CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes a No 1fNo, completeand submit the VariancelAlternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fist Track Application and supporting documents. 2_ Professional Engineer's Certification: 1, Jeremy S. !card attest that this application for (Professional Engineer's name from Application Item I11_1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version); and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes I43 215.6A and .143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as well as civil penalties up to S25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: ‘ �H C�RO 0 ••• s (, • �2Q y i f EAL/r 264 Fd9}' S . �G ����111111Iti� 3. Applicant's Certification per -15A NCAC 02T .0106(b): 1, Daren Lucas _ attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required suppaxtmg documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non- discbarge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required_parts of this application package are not completed and that if all required supporting information aad attachments are not included; this application package will be returned to me as - incomplete., NOTE — In accordance with General Statutes 143-215.6A and 14.3-215 6B, any person who knowingly makes any false statement,_rrprtatiok or certification in anyapplication package _shall be guilty of a' Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as'civll penalties up,to S25,600 per violation. May 25, 2018 ENGINEER'S REPORT Steele Creek Multi -Family LDI Project No. 1016351 SEWER SYSTEM APPLICANT: Steele Creek Rivergate Apartments, LLC 3010 High Pine Church Rd. Asheboro, NC 27205 DEVELOPER: Steele Creek Rivergate Apartments, LLC 3010 High Pine Church Rd. Asheboro, NC 27205 DESCRIPTION: The site consists of approximately 41 acres. The property is zoned UR-2 (CD) and will consist of 408 apartment units and approximately 1,265 LF of 6" PVC sewer main on -site that will make up the private system. Flows from the project will be sent to the McAlpine Creek, Irwin Creek, and Sugar Creek Wastewater Treatment Plants (NPDES permit numbers NC0024970, NC0024945, NC0024937). SEWER SYSTEM IMPROVEMENTS: The proposed demand for this site will be approximately 56,855 gallons per day. The demand is based on 408 apartment units at 135 gallons per day/unit, a pool with 165 users at 10 gallons per day/user and a Leasing office with 5 employees at 25 gallons per day/employee. New mains are expected to have a minimum 50-year service life. The system will be constricted by the Developer per Charlotte Water Standards and Specifications and services will be billed by the City of Charlotte in accordance with their standard rate schedule. N:1 2016110163511OOCSIPERMITTINGTERMIT FORMSIPRVT SS NCOEQ11016351-ENGINEERS REPORT SEWER.00C LANDDESIGN, INC. Polaris 3G Map -- Mecklenburg County, North Carolina 12813 Walker Branch Dr. ©ate Printed: 5/5/203 ` 2:46:45 P This map or report is prepared for the inventory of real property within Meckktenburg County and is compiled from recorded deeds, plats, tax maps, surveys, planimetric maps, and other public records and d Users of this map or report are hereby notified that the aforementioned public prirnary information sources should be consulted forverification, Mecklenburg County an responsibility for the information contained herein. mapping contractors assume no legal EX, SEWER -- PROP, SEWER CONNECTION P SE° ER CONNECTION CHARLOTTE WLTE! R June 5, 2017 Mr, Jeremy Icard LandDesign, Inc. 223 N Graham St Charlotte, NC 28202 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE STEELE CREEK MULTI -FAMILY 12813 WALKER BRANCH DRIVE, CHARLOTTE NC CLTWATER TRACKING# 2017778 After an analysis of the sanitary sewer associated with the proposed design of project, Steele Creek. Multi -Family, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 56,855 gallons per day (408 apartment units x 135 gpolunit; 165 person pool x 10 gpd/person; 5 employee office x 25 gpdfemployee) at the connection point(s) indicated on the submitted utility plan for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached NC DEQ FTSE form, Charlotte Water (CLTWater) agrees to furnish water to the subject project, The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. The applicant should understand that due to the involvement of other agencies and continuing growth of the water system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained construction has not started within one (2) year of issuance of this flow acceptance, and payment for any service connections have not been received within (2) year of issuance of this flow acceptance Letter, this flow acceptance approval shall be rescinded and a new flow acceptance request must be made. If you have any questions, please do not hesitate to contact me at (704) 336-1006. Sincerely, � �e Gwendolyn Banner Engineering Assistant Charlotte Water 5100 Brookshire Bivrl ch rlotte, NC 2 216 char .e ater.org Operated by the City of Charlotte 'Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: LandDes ign, Inc. Project Name for which flow is being requested: Steele Creek Multi -Family More than one FTSE may be required for a single project if the owner of the WYYTP is not responsible for all pump stations along the route of the proposed tivastewaterfiow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, 'Sugar Creek b. WWTP Facility Permit II: NC0o24970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flares are in MGD 99.0 11.936 62.896 0.057 74.889 75.7% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Steele Creek 7.90 3.16 3.98 0.96 4.95 -1.79 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Walker Branch Out fall, Tributary 1 (1992) Downstream Permit Number: WQ0005993 Page 1 of 6 FTSE 04-16 III. Certification. Statement: j Carl Wilson certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which 1. am the responsible party. Signature oft is form indicates acceptance of this wastewater flow. Signing 1eia1 Signature oeo I7 D fe Page 2 of 6 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit'a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 19.6% % and 0.969 MGD of the Available Capacity (E) in Pump Station Steele Creek ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0. 969 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Steele Creek LS Replacement and FM Relocation is in design or under construction with planned completion in March 2018 ; and/or d. The following applies: The Steele Creek Pump Station replacement pro'lect will provide a new regional facility capable of handling build -out flows in the basin. Construction is expected to be complete by March 2018. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. I43-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Page 3 of 6 FTSE 04-16 North Carolina Secretary of State Search Results Page 1 of 2 • File an Annual ReportlAmend an Annual Report • Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings • Print an Amended a Annual Report form • Print a Pre -Populated Annual Report form Limited Liability Company Legal Name STEELECREEK RIVERGATE APARTMENTS, LLC Information Sosid: 1522816 Status: Current -Active Annual Report Status: Current' Citizenship: Domestic Date Formed: 6/8/2016 Fiscal Month: January Registered Agent: ACBC Properties, LLC. Addresses Principal. Office Reg Office Reg Mailing Mailing 1640 US Hwy 64 West 1640 US Hwy 64 West PO Box 280 PO BOX 280 Asheboro, NC 27205 Asheboro, NC 27205 Asheboro, NC 27204 Asheboro, NC 27204 Company OfficiaLs All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Managing Member Chad Branson PO BOX 280 ASHEBORO NC 27204 Managing Member Brian Lucas PO BOX 280 ASHEBORO NC 27204 Administrative Member Stephanie Branson PO BOX 280 ASHEBORO NC 27204 Managing Member Darren Lucas PO BOX 280 ASHEBORO NC 27204 Managing Member Carrie Coleman PO Box 280 Asheboro NC 27204 https://www.sosnc.gov/online_services/search/Business Registration_Results 5 /31 /2018 CREATING PLACES THAT MATTER. May 25, 2018 ENGINEER'S REPORT Steele Creek Multi -Family LDI Project No. 1016351 SEWER SYSTEM APPLICANT: Steele Creek Rivergate Apartments, LLC 3010 High Pine Church Rd, Asheboro, NC 27205 DEVELOPER: Steele Creek Rivergate Apartments, LLC 3010 High Pine Church Rd. Asheboro, NC 27205 DESCRIPTION: The site consists of approximately 41 acres. The property is zoned UR-2 (CD) and will consist of 408 apartment units and approximately 1,265 LF of 6" PVC sewer main on -site that will make up the private system. Flows from the project will be sent to the McAlpine Creek, Irwin Creek, and Sugar Creek Wastewater Treatment Plants (NPDES permit numbers NC0024970, NC0024945, NC0024937). SEWER SYSTEM IMPROVEMENTS: The proposed demand for this site will be approximately 56,855 gallons per day. The demand is based on 408 apartment units at 135 gallons per day/unit, a pool with 165 users at 10 gallons per day/user and a Leasing office with 5 employees at 25 gallons per day/employee. New mains are expected to have a minimum 50-year service life. The system will be constructed by the Developer per Charlotte Water Standards and Specifications and services will be billed by the City of Charlotte in accordance with their standard rate schedule, LAN©DESIGN+COM 223 N. GRAHAM STREET • CH:ARLOTTNC i8 22 • 704,333.0325 CHARLOTTE • WASHINGTON D.C. • DALLAS ORLANDO • SAN FRANCISCO • BOULDER rr;t:xra es Curley TO 1016351 STEELE CREEK MULTI -FAMILY 1016351 Steele Creek Multi Family Fast Track Sanitary Sewer Submittal For your approval Barry Love 1610 E Center Ave #301 Room # 3323 Mooresville NC 28115 United States Barry, and Design NCDENR Mooresville Regiona Office Transmittal 5/25/2018 00033 Mail anddesign,com barryiove@ ncdenr.gov Please find the attached package as our fast track sewer submittal for Steele Creek Mufti Family in Charlotte, NC. Steele Creek Multi Family sanitary sewer will serve 408 apartments, one pool, and a leasing office with 5 employees with an average daily discharge of 56,855 gallons per day of waste water. With this submittal we are hoping to obtain a construction permit for the subject private sanitary sewer system. The listed items below are included in this package for your review. • Application Fee of $480.00 made payable to "NCDEQ" Fast Track Application • Flow Acceptance • Site Maps Let me know should you have any questions.. Thanks, JAMES CURLEY Designer y Charlotte (o) 704,333.0325 Charlotte Washington DC 1 Dallas Orlando V San Francisco I Boulder La ttt ictra am j @LandDesignInc NRiDlev