HomeMy WebLinkAboutNC0041718_Compliance Evaluation Inspection_20211115ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Mr. Paul J. Smith 85 North Hillside Drive Myrtle Beach, SC 29582 NORTH CAROLINA Environmental Quality November 15, 2021 SUBJECT: Compliance Evaluation Inspection Clearview at Misenheimer WWTP NPDES Permit NC0041718 Stanly County Mr. Smith: On November 10, 2021, Roberto Scheller of this Office conducted a compliance inspection at the subject facility. This inspection was conducted as a Compliance Evaluation Inspection (CEI) to ensure compliance with permit requirements and conditions. At the time of inspection facility appeared to be well operated and was producing a good quality effluent. We wish to thank the operating staff for assistance regarding this inspection. The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact myself or Roberto Scheller at (704) 235-2204 or roberto.scheller@ncdenr.gov. Enclosure: CEI Report Dap®rlmant of Enr romrcnlal Ouant_NORTH CAROLINA Sincerely, 1- DocuSigned by: P444.4 �F 161 FB69A2D84A3... for W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IN Code I 2 IL NPDES yr/mo/day Inspection Type Inspector Fac I 3 I NC0041718 111 121 21/11/10 117 1810I 19I S I 2011 Type 21IIIIII IIIIIIIIIII IIIIIII I IIIIII IIIIIIIIIII P6 Inspection 671 Work Days Facility Self -Monitoring I 70I3 Evaluation Rating I 711 B1 1 72 QA I N I 73I 1 I I Reserved 74 71 J I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Clearview at Misenheimer 48708 US Hwy 52 Misenheimer NC 28109 Entry Time/Date 11:48AM 21/11/10 Permit Effective Date 19/04/01 Exit Time/Date 12:39PM 21/11/10 Permit Expiration Date 24/02/29 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// John Walter Ritchie/ORC/704-788-4164/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Paul J Smith,85 N Hillside Dr North Myrtle Beach SC 29582//843-280-4460/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Roberto Scheller of Inspector(s) Agency/Office/Phone and Fax Numbers Date ,-Docusigned by: 11/15/2021 DWR/MRO WQ/707-235-2204/ 54.., "-91C2A007838943E... Signature of Man W. Corey Ba emMuaNellgewer for WCB Agency/Office/Phone and Fax Numbers Date inge4F161Fr BH69A2D84A3P R/Division of Water Quality/704-235-2194/ 11.15.21 ... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES yr/mo/day NC0041718 111 121 21 /11 /10 117 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The current permit (NC0041718) became effective April 1, 2019 and expires on February 29, 2024. Permit is for the continued operation of an existing 0.005 MGD extended air wastewater treatment system that discharges into Curl Tail Creek which is classified as WS-IV water in the Yadkin -Pee Dee River Basin. Facility consist of Barscreen, Aeration Basin, Two (2) Aeration Blowers, Clarifier, Chlorine Contact Chamber with Tablet Chlorine and Dechlorination, and Effluent Air Diffuser. Effluent discharges into Curl Tail Creek via outfall #001. Review of compliance history was conducted from October 2020 through September 2021. Violations were noted for Daily Maximum Limit Violations of Fecal Coliform on June/2021, July/2021 and August/2021. At time of subject inspection facility appeared to be well operated. Effluent at point of discharge was clear with no visible suspended solids. There was no foam or floating solids at the point of discharge. Page# 2 Permit: NC0041718 Inspection Date: 11/10/2021 Owner - Facility: Clearview at Misenheimer Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? • ❑ El El # Are there any special conditions for the permit? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Records and copy of permit are stored off site due to vandalism. Bar Screens Type of bar screen Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Yes No NA NE Page# 3 Permit: NC0041718 Inspection Date: 11/10/2021 Owner - Facility: Clearview at Misenheimer Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE a.Manual • b.Mechanical ❑ Are the bars adequately screening debris? • ❑ ❑ ❑ Is the screen free of excessive debris? • ❑ ❑ ❑ Is disposal of screening in compliance? • ❑ ❑ ❑ Is the unit in good condition? • ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? El El • ❑ Are the diffusers operational? • El El El Is the foam the proper color for the treatment process? • El ❑ ❑ Does the foam cover less than 25% of the basin's surface? • El El El Is the DO level acceptable? • El ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/I) El El El • Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Page# 4 Permit: NC0041718 Inspection Date: 11/10/2021 Owner - Facility: Clearview at Misenheimer Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Comment: Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? • ❑ ❑ ❑ Are the tablets the proper size and type? • ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ El • Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? • ❑ ❑ ❑ Comment: De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? • ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ • ❑ # Is de -chlorination substance stored away from chlorine containers? El El ❑ • Comment: Are the tablets the proper size and type? ■ El El El Are tablet de -chlorinators operational? • El ❑ ❑ Number of tubes in use? 2 Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • El El El Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable MOE El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: At time of inspection effluent was clear with no visible suspended soids. Page# 5