Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0039667_Regional Office Historical File Pre 2018
Water Resources Environmental Quality December 7, 2017 Mr. Daniel K. Williams, Chief Investment Officer Meritex Charlotte II LLC - 25 University Avenue NE, Suite 200 • Minneapolis, MN 55413 Dear Mr. Williams: ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director Subject: Permit No. WQ0039667 Meritex Charlotte it LLC CLT Logistics Wastewater Collection System Extension Permit Mecklenburg, County In accordance with your application received December 4, 2017, we are forwarding herewith Permit No. WQ0039667 dated December 7, 2017, to Meritex Charlotte 11 LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall. be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Conditions 1.1 & 1.2: Alternative designs are granted relative to the minimum slope of the sanitary sewer and minimum separation distance from wetlands, per 15A NCAC 02T.0105(n). Please see Conditions 1.1 and 1.2 for more details. Condition 11.1: Condition 11.4: This- permit shall not be automatically transferable; a request must be made .and approved. Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Nothing Compares— State ofNorth Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704-663-1699 If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Barry love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. Sincerely, by W."'trey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Jeffery C. Orsborn, P.E. (e-copy) Barbara Gross (e-copy) Tommy Rowland (e-copy) Regional Office Files Water Resources Central Files PERCS (e-copy) 2 Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the .provisions of Article 21 of Chapter 143, General Statutes of North Carolina as - amended, and other applicable Laws, Rules, -and Regulations, permission is hereby granted to Meritex Charlotte II LLC Mecklenburg County for the construction and operation of approximately 1,739 linear feet of 8-inch gravity sewer, a 0.008975 MGD pump station with .duplex pumps, on site audible and visual high water alarms, telemetry, and a portable generator receptacle; as well as approximately 697 linear feet of 2-inch force main to serve the CLT Logistics project, and the discharge of 8,975 gallons per day of collected industrial wastewater into the Charlotte Water- existing sewerage system, pursuant to the application received December 4, 2017, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently -filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall • e effective from the date of issuance until rescinded and shall be subject to the specified • cond ions and li ' itat'. ns contained therein. by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0039667 Permit Issued: December 7, 2017 3 SUPPLEMENT �� ������U�� � ������ o�� PERMIT n^���m.o* .�u�m~u�n Meritex Charlotte 11 LLCi5hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Plant in accordance with Permit Number NCO024970. Permitting of this project does not constitute an acceptance of any part of the projectthat does not meet 15A N[AC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the, Division's Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. L SPECIAL CONDITIONS 1. No flow in excess of the quantity permitted herein, 8,975 gallons per day, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted tmand approved bythe Division. [1SANCACO2T.0]04(b)] 2. This permit shall become voidable unless the agreement between K4eritex[harkztte U LLC and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. [15A 3. Each pump station shall beclearly and conspicuously posted using a weatherproofsign with apump station identifying name/number, I4'Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event ofalarm activation orother emergency. Simplex pump stations orvacuum sewer pits serving asingle- family residence may have a placard or sticker on the control panel in lieu of sign. D5A N[AC0ZT UN.STANDARD CONDITIONS 1. This permit is not transferable, In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Pennktee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials asmay beappropriate. The approval ofthis request shall beconsidered mnits merits and may ormay not beapproved, [15ANCA[OITD1O4;G.8143'I15.1(d3)] 4 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to .prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows, Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons,that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any 55O and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence, This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the 550 was beyond control. [G.S. 143-215,1C(a1)1 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed. Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: 6 a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station' buoyancy, wet well storage, surge protection, detention time in the wet welt, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)1 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and. Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0148(b)1 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)} 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERM ITTEE: PERMIT #: PROJECT: ISSUE DATE:. Meritex Charlotte II LLC WQ0039667 CLT Logistics December 7, 2017 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow- made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION 1, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION I, , as a dul registered Professional En Engineer in the State of North Carolina, having been authorized to observe (periodically, ❑ weekly, E] full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation -of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final ❑ Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Offieel 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28I15 Dlvllon of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC () T .0300 FAST TRACK SEWER SYSTEM EXTENSION APPLICATION I, 1 A 04-16 & SUPPORTING DOCUMENTATION Application N€unber: /Q , ( (to be com,plc1ed AU items roust be completed or the application .will be returned APPLICANT INFORMATION. 1. Applicant's name: Meritex Charlotte 2. Applicant type: LJ Individual ❑ Federal ure au LC (company, munieipality, I-iOA, utility, Corporation ❑ General Partnership El State./County El Municipal Ltatnel . Williams per 15A, NCAC 021' .0106(b) Title: Chief ln��estrtaent Officer 4. Applica. ddress: 25 y Avenue NE. Suite 200 City: Minneapolis 5. Applicant's contact information: Phone number: (651) 855-9684 I..avail Address: a arertrzmcritex com MN Zip: 55413- ❑ Priva.tely;-(1) ned Public Utility ❑ Other II. PROJECT INFORMATION: 1.. Project name; CL"I' Logistics 2. Application/Project status: 7 roposed (Neuw Permit) ❑ Existing I unit/1 If a m,odifieation, provide the existing permit number: WQOO and issued mite: If new construction but part ofa master plan, provide the existing permit number: W(0 3, County Wtitere project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.192 Longitude:-80.935' 5. Parcel ID (if applicable): 141-054-37 (or Parcel ID to closest downstream sewer) CONSULTANT INFORMATION: 1. Professional Engineer: Jeffery C, Orsborn License Number: 028786 l^irm: Orsborn. Engineering Group. PA. Mailing address: 610 East Morehead St. Suite 106 City: Charlotte State: NC Zip: 28202-2614 Phone number: (704) 749-1432 Email Address: jorsbonildorsbonr-eng.com.. IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:. 1. Facility Name: McAlpine Creek Permit Number:. NC0024970 Owner Name: CL'TWater (CML7f)) V. RECEIVING DOWNSTREAM SEWER INFO.R.MATION (if different than WWTF): 1. Permit Number(s): WQ unknown Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Numbers) (if applicable): WQCS Owner Name(s): CLTWater (CMUI)) 'TA 04-16 Page 1. o1 5 VI. GENERAL REQUIREMENTS If the Applicant is a Privately -Owned Public 'ty, 2. If th.e Applicant is a .1_ If the Applicant is las a Certificate of Public Conve cnce and Necessity been attached? El Yes 0No N/A ts to be sold, has a Developer's Operational Agreement (FORM: DFV) been attached? El Yes 0No N/A Ow. ers' Association has an t. A ee .en ")A.laden attached? El Yes 0No N/A 4, Origin of Avastewater (check all that apply): 0 Residential Owned O Residential Leased O School / preschool / day care .Food and drink facilities 0 Businesses / oll-ices / factories O Retail (stores, centers, .malls) 0 Retail. with food preparationiseryice El Medical / dental / veterinary facilities O Church O Nursing Home El Car Wash 0 Hotel and/or Motels El Swimming Pool /Clubhouse 0 Swimming Pool/Filter Backwash Other ( Warehouse 5, Nature of wastewater 0 % Domestic/Commercial 0 % Commercial 100 % industrial (See 15A NCAC 02T .0103(20)) ) Is there a Pretreatment Program in effect? 0 Yes 6. Has a flow reduction been approved under 15A .NCAC 02T ..01.14(f)? 0 Yes provide, a. copy of tlmv reduction approval. letter 7. Summarize wastewater generated by project,. No No (Warehouse) Establishment Type (see 02T.0114(D) Warehouse Office Daily Design thb Flow 100 gal/docks No. of Units 71 25 gal/employee 75 FloIN 7,100 GPD 1,875 GPD gall ga ga gal/ Total GPD GPD GPD GPD 8,975 GPO a See ISA NCAC 02T .011.4 b ,(1. andie)(2) for caveats to wastewater design..flow rates (i.e., minirnum flow per dwelling; proposed unlaiownnon-residential development uses; public access facilities located near high public use areas, and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 1.5A NCAC 021" .0114:(c), design flow rates for establishments not identified [in table 13A NCAC 02T,01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project.; 8,975 GPD (per 15A NCAC 02T .0114) Do not include future :flows or previously permitted allocations If permitted flow is zero, indicate why: O Pump Station or Gravity Sewer Vlthere flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in PermitNumber: 0 Rehabilitation or replacement of existing sewer with no new flow expected 0 Other (Explain): FORM: FTA 04-16 Page 2 of 5 GRAVITY SE ER DESIGN CRITERIA (If Applicable) - 02T ,0305 11vI:DC' (G ravitr° Sew ummarizc gra be d. the 1v11.)C for Perm tin )rrnation related to rrunimum zing lines to meet minimum slope requirement is not allowed and a violation of .the MDC Length (l:tx t) Material PVC •o design err te V111. PUi4TP STATION DESIGN CR1'T.ERIA (If Applicable.)-02T .0305 & MDC (Pump Stations/Fore e Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station rrtra°tJ.. Approximate Coordinates (1)e iraa<:rl l)cgre s): Latitude 35,193` l.caragittade: Kt.),'135 3, Design flow ofthe pump station: ().00I 75 millions gallons per day (firm capacity) 4. Operational points) ofthte. pump(s): 49 gallons per minute at 554 feet total dynamic hr 5. Summarize the 0 rce main to be permitted Or this Pump Station):: Sia 6. Power relia Length (feet) A NCAC 0 0 Standby power source or purup 5A NCAC 021' .(:) > Required for all pump stations withan average daily tlow greater than orequal to 15,(:)CK) s allons per Must be permanent to facility Or if the pump station has an average daily How less than 15,f30p gallons per day: Portable power source with rrvan uarl activation, quick -connection r ptacic and trticnietry> I5A l CAC 02'T` .0305(h)(1)(i.') or 0 Portable pumping to it n th pl It shall be demonstrated to the and is compatible with the statton. It' the potable power source or pump i dedicated to multiple pump stations, ate c:e•alt,ttrtion of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel t.imefratnes, shall be prodded in the case of a multiple station power outage, ed crrtergency pump connection and telemetry - I ill NCAC 02T .0305 d or contracted by pplicant (di I)(Cy f agreement) A04-16 SETBACKS & SEPA.RATI©NS — (0213.0200 1.5A NCAC 02T .0305( Does the projcc 15A NCAC 02T rater mains (hf)ri with all separationsf'c)tr9td in f5r NCAC 3050) Contauls Irtlrr0.al ritback Paraat3ie lairned water lines (°cortical-rec�luin izontal Ans private or pu 'r d over sewer) ;d lie s eluding any Wells, WS-1 waters of Clan; 11 impounded reser't'rs used as a source of drinking water ept. \ S-.l or WPS•V). 13.E SA, C)RW 11(„ W, or 513 front rrcrrntal ion) and wetlands (see item IX.2 ) impoundment, or ground water lowering and surface drainage ditches Any bui earth gr El Yeas ❑ No 24 inches 2 feet. 5 feet. 10 feet 10 feet r 15A NCAC CI- .0305(g) contains aalterriat:i es +vlaere separations to 02T.0305f 6'Q cannot be acliie sred. y **Stream < lassificaations can be identified. using the I.,)ivision's NC Surface Water CI tt sif'acations rvebpaage ban with 021 0305(f) or 1g tie. Section X of this application. Does the projec See the I)i‘i sior • No Variance is required if the alterna As built documents should reference the k Does the prig ee • T1ris would th separation req • lands? (5- feet of sa:partrtion) ® Yes ( No separation cannot be meet s utilized in design and con,stntctic tiith all setbacks found ila the ricer basin rules per I5A NCAC 0213 .0200? rout 13u11`ercd Streams per 15A NCAC 213.0202. 4, 1 oe, the protect comply \\ith ten indi\'ideal 404 Permit or arty' 40 ➢ Certifica • Wetland -related permits shall tn: requested, obtained, ed to 1:or projects flail im Infrrmat.ion cY.n be obtained tironi Uie 401 & Buffer Pei-mittinI rarrela 15A NCAC" 0217.0105(c4(6) (additional permitslcertitiicataontiY ®Yes 5 or surface \Viilt.TS Yes Q No Per 15A NCAC 02'"1°•01C)Sfc)(Ea), drteetlti related Litviroruttetatal pertaiits or certificaaticin alaplications aie heir'tg prepared have been. applied for, or hai` this lx raatit is c cmtingc nt ern i sta exec caf dei ndent permits (erosion and sedimentation control plains, storm.\\atct rn:l agement plans, etc. s this prcJject l5A NCAC t3: boned parallel elude a 14l)2, "high-pric>rit sta'eambank,s than meat \\it n lines that are deemed "high-priorit)'i" cr'' tneans "any aerial se\ er, seer contacting surf€tcc ieet to erosicart that undermines or deteriorates the see•\er, N pe (aerial line, size, rnateriale and locatit High priority lines shall be inspected by the permittm or its representative at 'least once every si tnths and inspections documented per 15A NCAC 02T.0403(a)(5) or the perrnitee's individual SYstern-Wide Collection permit. "1'A 04-16 a•4 of 5 rx.. CERTIFICATIONS: 1. Does the ssubrnitted system comply with 1.5 . and Force e i'ytarris jlatest sea-snon). and the he \1 No as app If No, complete and submit the 'V ariancee/Alternative Design Request application (VADC 10-14) and supporting documents for review, Approval of the request is required prior to submittal of the Fast Track Application and supporting documents, 2. Professional Engineer's Certification: effery C. Orsborn (Professional Engineer's name from Application Item [11. attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track. Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to he consistent with the proposed design. NO I"F — In accordance with General Statutes 143-215.6A and 143-215,6B, arty person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T ,0106(h): Daniel K. Williams; Chief investment Officer attest that this application fo (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this pemtit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143 15.6A and l4 15 bf3, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 04-16 Page 5 of 5 ORSBORN ENGINEERING GROUP CLT Logistics Charlotte, North Carolina Project Narrative October 23, 2017 This site was partially developed in 1998-99 with one flex industrial building, supporting parking, and truck court. At that time, the site was pre -graded for an additional two buildings, and storm infrastructure, including a detention pond, was installed for the existing building as well as the currently proposed building. Current phase includes construction of 3 industrial buildings on the previously graded building pads totally approximately 122,200 sf total. Building 1, 2, & 3 is served by a private 10" sewer collection system that routs to a sanitary lift station located on -site. The pump station feeds a 2" force main running to a private manhole. From the private manhole, proposed system will gravity to an existing public sewer manhole that serves the neighboring parcel. 610 EAST MOREHEAD STREET, SUITE 106 Page 1 CHARLOTTE, NC 28202 p) 704.749.1432 F)704.749.1433. CHARLOTTE W October 12, 2017 Mr, Blong Yang Orsborn Engineering Group 610 E Morehead St Charlotte, NC 28202 TER SUBJECT: WATER AND SEWER FLOW ACCEPTANCE CLT LOGISTICS 4624 BELLE OAKS DRIVE, CHARLOTTE NC CLTWATER TRACKING# 20171383 After analysis of the sanitary sewer associated with the proposed project, CLT Logistics, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 8,975 gallons per day (75 employees x 25 god/employee; 71 loading docks x 100 gpd/dock) at the connection point(s) shown on the submitted utility plan for transmission to the McAlpine Creek Wastewater Treatment Plant, NPDES permit number NC0024970, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached NCDEQ FTSE form. Charlotte Water (CLTWater) agrees to furnish water to the subject project, The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow.. The applicant should understand that due to the involvement of other agencies and continuing growth of the water system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct permits are not obtained construction has not started within one (1) year of issuance of this flow acceptance, and payment for any service connections have not been received within (1) year of issuance of this flow acceptance letter, this flow acceptance approval shall be. rescinded and a new flow acceptance request must be made. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant Chariot el, ter 51'00 Brookshire Blvd, CIwrlotte, NC 28216.char k tevvater.uig Operated by the City of Charlotte Division of LR)atcr Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Orsborn Engineering Group Project Name for which flow is being requested: CLT Logistics More than one F7SE may be required far a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used Ali flows ate in MGD 99.000 12.859 64.375 0.008 77.242 7B.0¢ II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)�A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): wilmont; Road Downstream Permit Number: 6594 Pagel of 2 FTSE 04-16 III. Certification Statement: 1 Carl Wilson certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this)rin indicates acceptance of this wastewater flow. Signing Offici44 Signature Page 2 of 2 fdr7/ l7 ate FTSE 04-16 JOB SI PROPOSED GRAVITY , SANITARY SEWER f PROPOSED SANITARY - FORCE MAIN 17023 RR07bSED GRAVITY SANITARY SEWER SCALE: 1" = 500' DRAWN BY: CJ BB APPROVED BY: JC0 BUILDING 1 EXISTING SANITARY SEWER PROPOSE© SANITARY SEWER PUMP STATION ,SITE BCUNDARY USGS QUAD MAP EXHIBIT FOR CLT LOGISTICS CHARLOTTE, NORTH CAROLINA ORSBORN ENGINEERING GROUP 610 EAST MOREHEAD SEREE.1, SUITE 106 CHARLOTYE, NC 28202 P) 704-749-1132 , 9 704-749-1433 T H E MERITED COMPANY ESP 191E VIA EMAIL November 27, 2017 Re: 4624 Belle Oaks Drive (CLT Logistics Development — Phase 02T,0305(h)(1) — Property Mana.gernent Services To Whom ay Concern: 0 iability Plan Per 1.5A NCAC As you may be awvare, Meritex Charlotte It., LLC ("Mertes") is in the process of obtaining all necessary permits to construct a multi -tenant industrial building at 4624 Belle Oaks Drive in Charlotte, NC and intends to install a private sewer line which includes a lift station for the future building(s) on the property, As such, per the section H. of the NCDENR Private Sewer permit application regarding the Power Reliability Plan and as further described in section 15.A NCAC 02T.0305(h)(1), 1 eritex has engaged Foundry Commercial. for property management services, and through their vendors, they have made availabl.e an on -call emergency/temporary portable power generation unit and associated appurtenances and personnel for distribution and operation of this pump station. Should you have any questions or comments, pleas feel free to reach me at mwagnerameritex.cona Matt W agri Director of Acqui ions North Carolina Secretary of State Search Results Page 1 of 1 Limited Liability Company Legal. Name Meritex Charlotte I1, LLC information Sosld Status AnnuaL Report Status Citizenship Date Formed 1528802 Current -Active Current Foreign 7/6/2016 FiscaL Month: State of Incorporation Registered Agent December DE CT Corporation System Addresses Reg Office Reg Mailing Mailing 160 Mine Lake Ct Ste 200 160 Mine Lake Ct Ste 200 24 University Avenue NE, Suite 200 Raleigh, NC 27615-6417 Raleigh, NC 27615-6417 Minneapolis, MN 55413-2480 Principal Office 24 University Avenue NE, Suite 200 Minneapolis, MN 55413-2480 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Manager Meritex Industrial Investments I11, LLC 24 University Avenue NE, Suite 200 Minneapolis MN 55413 https://www.sosnc.gov/online_services/searchBusiness_Registration_Results 12/5/2017 ORSBORN ENGINEERING GROUP 610 EAST MOREHEAD STREET, SUITE 106 CHARLOTTE, NORTH CAROLINA. 28202 PHONE 704.749.1432 FAx 704.749.1433 TRANSMITTAL Project: 17023 CLT Logisti To: Fast Track Permitting Date: 11/30/2'017 NCDENR 610 E. Center Ave, Mooresville, NC 28115 (704) 663-1699 Qty. Date 2 1 Applications Fee $480 Sent Via: FedEx Flow Acceptance/Flow Tracking SGS Quad Map Cover Letter Power Reliability Plan Lette! ® For Approval C For Your Use 0 As Requested Description Q' For Review and Comment 0 Approved as Submitted 0 Approved as Noted Copied To: Signed: Blong Yang, El _ Returned for Corrections 0 Returned After Review 0 Resubmit for Approval Permit Number WQ0039667 Central Files: APS ^ SWP _ 121i/2017 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions 1.00 Individual Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 8,975 Facility Permit Contact Affiliation Facility Name MajorlMinor Region CLT Logistics Minor Mooresville Location Address County Mecklenburg Facility Contact Affiliation Owner Owner Name Meritex Charlotte!! LLC Dates/Events • Owner Type Non-Govemment Owner Affiliation Daniel K. Williams 25 University Ave Ne Minneapolis MN 55413 Orig Issue 12/7/2017 App Received Draft Initiated 12/4/2017 Scheduled Issuance Public Notice Issue Effective Expiration 12/7/2017 12/7/2017 Regulated Activities Requested !Received Events Wastewater collection Additional information requested Additional information received Outfall Waterbody Name Streamindex Number Current Class Subbasln W Q R O a EAST T'RACK,SE'4dy"Ef ENGINEERING CERT1IFICAT!t N PERMITTEE: Meritex Charlotte ll LLC PERMIT #: WQ0039667 PROJECT: CLT Logistics ISSUE DATE: December 7, 2017 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Perrnittee is responsible for trucking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERM TTEE'S CERTIFICATION I, the undersigned agent for the Perrnittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted tweet r portions hereof. Raymond E. Kivett; Chief Investment Officer Printed Name, Title r" Sign ENGINEER`S CERTIFICATION 1, Jeffery C. 0rsborn , as a du registered Professional Eneer in the State of North Carolina, having been authorized to observe (Jperiodically, weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 1SA NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ® Final Li Partial (include description) Certification Comrnents/°C tlalifiers (attach If necessary): State or North Carolina Environmental Quality] Water Resources { Water Mooresville Regional Office) GIi East Center Avenue, Suite JU N i Mooresr try Regional Operations Kor h Carolina 281 15