Loading...
HomeMy WebLinkAboutWQ0039475_Regional Office Historical File Pre 2018Water Resources Environmental Quality September 18, 2017 Mr, Joseph C. Wilson, Chief Engineer Charlotte Water 5100 Brookshire Blvd. Charlotte, NC 28216 OY COOPER Governor MICAEI S. REGAN Secretary S. JAY ZIMMERMAN DarccWr Subject: Permit No. WQ0039475 Charlotte Water Mint Hill Commons Phase 2 Wastewater Collection System Extension Permi Mecklenburg. County Dear Mr. Wilson: In accordance with your application received September 11, 2017, we are forwarding herewith Permit No. WQ0039475 dated September 18, 2017, to Charlotte Water (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11,1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §1.43-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board,. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. >"-No'thinq Compares State of North Carolina 1 Environmental Quality l Water Resources Water 9 u Mooresville Regional Office l 610 East Center Avenue, Suite 301 1 Mooresvil 704-663-1699 itya Regional Operations If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov, bvVV.Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division ofWater Resources, NCDEC\ cc Anthony Brent Cowan, P.E.he-coov> Barbara Gross (e-copy) Tommy Rowland /e-copy\ Regional Office Files Water Resources Central Files Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143; General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Charlotte Water Mecklenburg County for the construction and operation of approximately 5,594 linear feet of 8-inch gravity sewer, a 0.121 MGD pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and a permanent generator with automatic activation;: as well as 599 linear feet of 4-inch force main to serve the Mint Hill Commons Phase 2 project, and the discharge of 24,120 gallons per day of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received September 11, 2017, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design. Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. e by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0039475 Permit issued: September 18, 2017 SUPPLEMENTTO .���v n m.u.n�nn_omo u�� vo�"=v�nvu ~�"�'�o-"n~vvv"�w.o Charlotte Water is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Plant in accordance with Permit Number NCO024970, Permitting ofthis project does not constitute amacceptance of any part of the project that does not meet 15A NCAC2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carol ina-licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed projectmeets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. t SPECIAL CONDITIONS 1. No flow in excess of the quantity permitted herein, 24,120 GPD, shall be made tributary to the subject sewer, system until an application for permit modification for an increase inflow has been submitted toand approved bythe Division, [15ANCACO2T.0304[b)] I. The Operational Agreement between the Permittee and the Environmental Management Commission iSincorporated herein bvreference and shall beacondition ofthis permit. Noncompliance with the terms of the Operational Agreement shall subject the Pe,mittee to all sanctions provided by North Cdro|inaGenere)Statute$§143-316.G4to§143'Z15.6[forviV|adon ure ` tuact -i /ccordmnce with the terms and conditions of this permit. [16A N[ACO2T.O115] 11. STANDARD CONDITIONS 1. This permit bnot transferable. |nthe event there isadesire for the wastewater collection facilities to change ownership, or there is a name change of the Pemnhtee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials aymay beappropriate. The approval ofthis request shall beconsidered onits merits and may ormay not beapproved. (15ANCA[8IT.O104;G.S14]-21S.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions Vfthis permit; l6ANCACZT; the Division's Gravity Sewer Minimum Design Criteria adopted February1Z, 199b,asapplicable; the Division's Minimum Design Criteria for 4 the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.01101 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are , documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, etc.|nr b. Any SSUand/or spill over 1,OOOgallons; mr c. Any SS0and/or spill, regardless ofvolume, that reaches surface water Voice mail messages orfaxed information is permissible, but this shall not beconsidered mathe initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone mumber(8OO) 858-0360 or/9l9\ 733-3300. Persons reporting any of the, above occurrences shall file a spill report by completing and submitting Part | of Form [3'SS0 (or the most current Division approved form) within five days following first knowledge ofthe occurrence. This report must outline the actions taken o,proposed tobetaken to ensure that the problem does not recur. Part ||nfForm [S-SS0(or the most current Division approved form) can also becompleted tushow that the SSOwas beyond control, [G.S.143-225'IC(a1)] G. Construction ofthe gravity sewers, pump stations, and force mains shall be scheduled »a as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tnthe surface waters ofthe State. [1SANCA[O2T.O1U8(b)] 7. Upon completion of construction and prior to operation of the�e permitted facilities, the completed Engineering Certificationform attached to this permit shall be submitted with the required supporting documents tothe address provided mnthe form. Acomplete certification ixone where the form is fully executed and the supporting documents are provided axapplicable. Any wastewater flow made tributary to the wastewater collection systenn extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permi1tce to appropriate enforcement actions. if the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions,, and Bylaws that have been appropriately filed: with the applicable Countys Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documentsare provided asapplicable. Supporting documentation shall inciuclmthe following: a. One copy of the project construction record drawings (plan& profile views of sewer lines& force mains) of the wastewater collection system extrnsion. Final record drawings should be dear on the plans or on digital media (CD or DV0 disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes.to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 11SA NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC Q2T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)] FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Charlotte Water WQ0039475 Mint Hill Commons Phase 2 September 18, 2017 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, n weekly, ❑ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 1SA NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final ❑ Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SY'STEM°'I EXTENSION APPLICATION FTA 04-1Ci & SUPPORTING DOCUMENTATION Application Number: All items must be cptm APPLICANT INFORMATION: t,leteed by t71r-"R d or the application will be returned Applicant's name: t hµtt"lotte Water (cotrtpatty, rnunicipant y, HOA., utility, etc) Applicant type" Individual Corporation C er°teral Partnership Federal StaleiCount> fl Municipal. 3A Signature authority's name: Joseph C. W1S[}n per 15Aa`l." Title: Chief Engineer 4. Applicant's nailing address. 5100 Brookshire I3lrrd. City: Charlotte State: North Carolina lip: 28216- 5. Applicant's contact information.: !'hone number: (704) 391-5169 !'mail Address: cwil errs r ci.charlotte.nc.us II. PROJECT INFORMATION: 1. Project narne: Mint Hill Commons Phase 2 Application/Project Status: LJ Proposed (New Perrrnit) If a modification, provide the ex Privately-C' E. Other Penna l ro date: If new construction hut part of a .master plan, provide the existing permit number: WQOO _ ..._ 3. County where project is located: Meecklenbu 4. Approximate Coordinates (Decimal Degre .$): 1_.:rtitude: 3m5.169` Long de: -80 6.57` 5. Parcel 11 (il` applicable): 1.95 ag permit number; '\ QOO (or Parcel 11 to closest downstream server) M. CONSULTANT INFORMATION: 1, Professional Engineer: Anthony Brent Cowan Firm: The Isaacs Group. P.C. Mailing address: 8720 Red Oak Blvd.,. Ste. 420 City: Charlotte State: NC 7i 28217 Phone number: (704) 227-9402 Email Address: hcotianaac.sgrp.coni IV. WASTEWATER TREATMENT FACILITY (%%WTF) INFORMATION: 1, Facility Name: McAlpine WW 1 P Permit Number: NC0024970 Owner Name: Charlotte Water Number: 02646' RECEIVING DOWNSTREAM SEWER INFOR °fATION (if different than W\%'"TF): 1. Permit Number(s): WQ297-638 Downstream (Receiving) Sewer Size: 8 inch. System Wide Collection System Pert it Number(s) (if applicable): WQCS Owner Nanne(s): Charlotte Water rued Public Ll :v FORM: FTA 04-16 Page 1 of 5 • VI. GENERAL REQUIREMENTS 1, If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities ❑ Businesses / offices / factories ❑ Yes ❑No //N/A ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels D Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) �Is there a Pretreatment Program in effect? ❑ Yes D No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(D) Daily Design Flow a,b No. of Units Flow Single Family Lot 190 gal/lot 90 . 17,100 GPD Multi Family Lot 135 galllot 52 7,020 GPD gal/ GPD gall GPD gal/ GPD gal/ GPD Tolad 24,120 GPD a See I5A NCAC 02T .0114(b), (d), (e)(1) and (e)(2.1 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities locatednear high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table ISA NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 24,120 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 GRAVITY SEWER DESIGN CRI'TE RLA (If Applieable) _ 021 .0305 & M I)C (Gravity Sewers): 1. Sununariie gravity sewer to be permitted: ngth (feet) 4995 Section.!! &III rrf"the NIDC for Pernnittin ref Gravity Section. III contains information related to minimum ,slopes fo Oversixing lines to meet minimum slope requirement is trot tallta v,ed and a violation of the MDC ins information related to design criteria V[II. I'UMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MD(' (Pump Stations Iaorce Mains, COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Proposed Pump Station Approximate Coordinates (Decimal Degrees). Latitude: ;35.168' l.on i de:-80.657' 3, Design flow of the pump station: 0.1,2l millions gallons per da,y (brut capacity) 4. Operational point(s) oldie pump(s):: 100 gallons per minute at 40.6 feet total dynamic tread (TDI-I) 5. Summarize th.e force main to be permitted (for this. Pump Station): inches) L.en th (feet) Material 4 743,21 .DIP 4 355,79 Power reliability in accordance with 15 NCACO21 ® Standby power source or pump wi th automatic activt°quoin and tele P'VC S,A NCAC 02`1'.0305(h)(1)(B): w !Required for all pump stations with. an average daily flow greater than or equal to 1.5,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: Q Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02 r .0305(h)(1)(C) or Portable pumping unit with plugged emergency pump con.nectrtan and telemetry - 15A NCAC 02T ,0 05(h)(1)(C'): It shall he demonstrated to the Division that the portable_ source is owned or contracted by the applicant. (draft a.greentent) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage, FORM: FTA 04-16 Page 3 of 5 IX. SE KS & SEPARATIONS -- (0213 .0200 & 15A NCAC 02T ,0305(f I. Due-; the project comply with all separations found in l 5i NCAC 02 p __U30.51_f) _( ). ater ma NCAC 02T.0305(f) co s and other utilities n horizo Reclairned vater Reclaimed wale ver se imnrum se . arat tback Parameter* d below h crtica includir cal - reclaimed over sewer) orizontal reclaimed over sewer ed trenches **Any private or public water supply source, including any we p rese ,.o ing water ass 11 impounded reservcirrs used as a soutee of "drinking r titers classified \\ S (except WS-I or WS-V), B. SA, ORW, HOW. or SB from nomral igh water (or tide elevation) and wetlands (see item. IX.2) ny other stream, lake, mimpoundment, or ground water loweringand surface draina ditches Any building foundatic An, basement. Top slope of embankment or cuts ot 2 fi DrainDrainags systems and interceptor drains I1 he provided for sewer systems: Separation Requ 24 inches 18 inches Any swimming pools al earth grade (wrertic.a tical height ,1- A NCACO2,..(., t.j3t 5 4 contains alternatives ww'here separations it 0 :, **Stream class' catioi ,' can he identified using the Division's NCSurface if noncompliance with 02 1,,t)30 4f}..oi see Section X of this application or J Yes feet 50 feet 10 feet 5 feet 10 feet 10 feet 5 feet 10 feet 36 inches ie ved. k ebnat<'; Does the project comply with separatioenrents for wetlands? (50 feet of separation) See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction v As built documents should reference the location of areas effected Does the proje ipty with all setbacks found in the rawer basin rules per This would irrelude Trout Buffered Streams per 15A NCAC 02 4. Does the project comply with an individual 404 Pernait or any 401 Certifications? "r* Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters Information can he obtained from the 401& Bul Ier.Pcrnnttifa< 13i uric h. No Does project cciittply= ww°jilt j v(m lC... b? 1 01t S{s)1!) (additional permit No El Yes No Per IS!1I aC\C _021, fffil5( 6j, directly related environmental permits or eertific*rtiean applicatitatas ai°e being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormww°ater management plans, etc=). Does this project include an lection litres that are deenr.ed "high -priori Per 1'+ \.NCAC 02'r 0402"high-priority sewer„ means "any aerial sewer, sewer contacting surface waters, siphon, or sense positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer_ © Yes No If yes, include an attachment with details for each line, including type (aeri High priority lines shall be inspected by the permi,tte Inspections documented per 15A NCAC 02T.0403(a)($) cr material, and location), its representative at least o -months and permitee's individual System- 4ide Collection permit. FORM: FTA 04-16 Page 4 of 5 CERTTF'1CATIONS: Doc's the submitted system comply with 1.5A .N_CAC (12T, the l:,tazatnurn llc i lr C't_itcri ft r the Per sttirlg of Puntp,Stattons and force Mains(ttcst v ersion), and the (r ryity Sewer rMinntttuin De- g st t ion) as applicable? Yes ❑ No If No, complete and submit the Variance'A.lternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. Professional Engmeer's Certification: attes oval. Engineer'"s name from Application Item this application for has been reviewed by the and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.t North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC 02T .0106(6)_ I, DPP C.. 103 (Signature Authority's name CI( gets, sot e.e from Application Item L3.) attest that this application for• has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that dal.' required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143 211 S. r 1 and 143-215.6-13, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which..may include a fine not to exceed $ I0,000 as well as civil. penalties up to $25,000 per violation. Signature: Da FORM: FTA 04-16 Page 5 of 5 Potaris G Map * Mecklenburg County, North Carolina Mint Hill Commons Phs 2 This reap or report is prepared for the inventory of Users of this map or report are hereby notified tha responsibility for the information contained herein. Date Printed: 8/4/2017 12:58:02 PIVI it in rtecklenburg County and is compiled from recorded deeds, plats, fax maps, surveys, planim ;trio maps, and other pubic records and data. Toned public primary information sources should be consulted for verification. fwlecklenburg County and its mapping contractors assume no legal Send To Printer Back To T"erraServer USGS 18 km E of Cha Proposed Pump Sta. 64 Change. to 11x17 Print Size Shoat/ Gr J_iots Change to Landscape e, North Carolina United States 01 Jul 1996 EXISTING RECEIVING 8" GRAVITY SANITARY SEWER INE (PERMIT" NCt. WC) 297-638) Image courtesy of the U.S. Geological Survey CO 2004 Microsoft Corporation. Terms of Use Privacy Statement DE€,Kior3 of State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: The Isaacs Group, P.A. Project Name for which flow is being requested: Mint Hill Commons - Ph. 2 More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC 0024970, NC 0024945, NC 0024937 All flows are in MGD c. WWTP facility's permitted flow 99.0 d. Estimated obligated flow not yet tributary to the WWTP 12.516 e. WWTP facility's actual avg. flow . 64.375 f. Total flow for this specific request 0.024 g. Total actual and obligated flows to the facility 76.915 h. Percent of permitted flow used 77.7% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm i pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Lawyers Road Sanitary Sewer Downstream Permit Number: 297-638 Page 1 of 6 FTSE 04-16 PIPIPPr-,1,11' III. Certification Statement: I Carl Wilson certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of is form indicates acceptance of this wastewater flow. r f�9pOZ/7 Signing 0 ial Signature Date Page 2 of 6 FTSE 04-16 CHARLOTTE W ',TER September 11, 20I7 North Carolina Division of Water Qr Water Quality Section 610. E. Center Avenue Mooresville, North Carolina' S'1 15. Re: Mint Hill Commons - Ph. 2 Pump Station and Force Main Application CMUD Project Number 100-17-501 Dear Sir: The enclosed submittal pack for the referenced project consists of a proposed pump station and force main to serve 142 single family lots. The collection system will be a public system owned and operated by Charlotte Water. Charlotte Water has agreed to accept the flow generated by this sewer extension. The package contains the following items. Fast Track Application- 1 original, 1 copy.. Application Fee- $ 480.00 s= Detailed Specifications- see plans Detailed Calculations- see plans FTSE 09.114 Forrn If you should have any questions, r. or Rick Bunton at 704-4 3'2-5099. ely, CI-IARII.C)TTE WATER hen G. Buchanan, PE ion and Development ,Serve Donated Projects Manager Senio. Enclosures Enclosures dditional intimmatit n f'Cc i free to give me a call at 704-432-5795 CHARLOTTE WATER. 600 East Trade Street, Suite 020 Charlotte, NC 28202 wwwcttarlottewater,©rg & Development Services FAX 704/432-5796 CourierNet NC Control Number: 1348211 Bt3L, - Curt No, '1348211 User Name: Company: The Isaacs Group 704-391-7700 eTrac Number: 141543321 01=4 Submitter Information Account: 50067 Name: The Isaacs Group Requested By: Karen Reference: 15089 BOL No.: Entered: 11-SEP-2017 10:16 Last Updated: 11-SEP-2017 10:25 (EST) Shipping Information Service Type: Return Servic Pieces: Weight: Charges: Quote: 1 Hour Rush None 1 0.0 Lbs. Q.00 0.00 Pick Up From Deliver To The Isaacs Group, P.C. Charlotte NC Karen Kocher 8720 Red Oak Blvd 420 CHARL©I 1 E, NC 28217 Phone: 704-527-3440 Charlotte Water 600 East Trade 020 CHARLOTTE, NC 28202 Phone: 704-839-4988 Pickup Details Delivery Details Requested Date: 11-SEP-2017 Ready Time: NOW Pickup Instructions: PU Check Actual Date: Arrival Time: Departure Time: Requested Date: Deliver By: Delivery Instructions: PU a Package Actual Date: Arrival Time: Departure Time: 11-SEP-2017 11:16 Driver: Date: Time: eTrac Order Entry C 2013 eTrac All rights reserved, Received by: Print Name: https:tiappsetrac. net/RetaiIOE/Tracking/ClyderDetails.asp?E_Number=1415433213,Print=Yes 111 G7 FNUINCEIRING DESIGN & LAND SURVEYING 8720 RED OAK BOULEVARD, STE, 420 CHARLOTTE, N.C. 28217 PHONE (704) 527-34.40 FAX (704) 527-8335 TO NCDEQ 610 East Center Avenue Ste. 301 Mooresville, NC 28115 WE ARE SENDING YOU ❑ Attached ❑ Shop drawings Copy of letter COPIES DATE ❑ Prints ❑ Disk NO. LETTER OF TRANSMITTAL DATE: ATTENTION: 0 7I.lOB NUMBER: Plan Reviewe RE: Mint Hill Commons Phs 2 . Barry Love Under Separate cover via ❑ Plans ❑ Applications the following items: Specifications $480 check for review fee DESCRIPTION Fast Track applications (one original plus one copy) Flow tracking acceptance form FTSE 8.5x11 color usgs map street level ma Set of design plans with specifications THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ For your use ❑ As requested For review and comment REMARKS ❑ Approved and submitted Approved as noted Returned for corrections ❑ Resubmit ❑ Submit ❑ Return copies for approval copies for distribution corrected prints Mr. Love, enclosed find the items listed above for your review and approval. This one is behind schedule in permitting and so any attention you could give this one to get the permit to construct out the door would be greatly appreciated! Let me know if you have any questions or comments. i can be reached at 704.227.9402 or bcowan@isaacsgrp,com COPY TO SIGNED Brent Cowan Permit Number • WQ0039475 Central Files: APS _ SWP _ 9/18/2017 Permit Tracking Slip Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuie Permitted Flow 24,120 Facility Status Active Project Type New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Mint Hill Commons Phase 2 Location Address 5100 Brookshire Blvd Charlotte NC Owner 28216 MajorlMinor Minor Region Mooresville County Union Facility Contact Affiliation • Owner Name Charlotte Water Dates/Events Owner Type Government - Municipal Owner Affiliation Joseph C. Wilson Chief E Engineer P 2100 Brookshire Blvd Charlotte NC 28216 Orig Issue 9/18/2017 App Received 9/11/2017 Regulated Activities Draft Initiated Scheduled Issuance Subdivision Wastewater collection Outfall Public Notice Issue 9/18/2017 Requested /Received Events Effective 9/18/2017 Expiration Additional information requested Additional information received 9/11/17 Waterbody Name Streamlndex Number Current Class Subbasin RECEIVEDINCIDENR/DWP FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Charlotte Water PERMIT tit; WQ0039475 PROJECT: Mint Hill Commons Phase 2 ISSUE DATE; .September 1.8, 2017 MOORESVIU.6' RE,GIONAL OFF [cE This project .shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation, it should be submitted in a manner that documents the Division's receipt Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address it the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall .subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials. have been submitted, PERMFTTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof, Q.-11E7P 6.72\ki Printed Name, Title Signature ENGINEER'S CERTIFICATION 2jZC Date 1, Anthony Brent Cowan as a duly 'registered Professional Engineer in the State of North Carolina, having been authorizedto observe (periodically, ri weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 021; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12., 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump .Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: [1 Final 41. Partial (include description) Includes sewer pump station and gravity sanitary sewer lines in Alta Lane, Bretton Woods Lane and Brighton Park Drivo bit Steamboat Dr, and Lawyers Road. Lots covered In this codification are singlo family lots 15-90 and town home buildings 5 and 6 Certification Comments/Qualifiers (attach if necessary): jail' signed by Anthony B. Cowan, RE, Date 2018,12.20 1456J/2-051Kr State of North Carolina 1 Environmental Quality 1 Water Rescocesi Wiier Quality Reenal Operetiniis Ntonresville Regiohal Oilicel 610 Last Center Amite. Suite 101. Mooresville, North Carclina 28115 CHARLOTTE TER December 28, 2018 Mr, W. Corey Basinger Regional Supervisor NCDEQ, Division of Water Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Subject: Request for Pump Station and Force Main Activation Permit. Mint Hill Commons — Ph. 2 CltWater Project Number: 100-17-501 NCDEQ Permit Number: WQ0039475 Dear Mr, Basinger: Enclosed please find one copy of each of these items: 1) Certificate of completion 2) Construction record drawings 3) Engineering calculations (Sheets 17, 18, 19) WORDS Please send the requested receipt of certification acknowledgement to me. See attached example. If you have any questions or need additional information, please contact me at 704-432-5099. Sincerely, CHARLOTTE WATER Fr derick D. Bunton Engineering Plan Reviewer Installation & Development Services rbunton@charlottenc.gov. cc: files Attachments rb CHARLOTTE WATER 600 East Trade Street, Suite 020 Charlotte„ NC 28202 nstallatio www.cha rlottewater. orL & Development Services FAX 704/432-5796