Loading...
HomeMy WebLinkAboutWQ0039390_Regional Office Historical File Pre 2018AL Water Resources Environmental Quality August 7, 2017 Mr. Tim McCollum, Principal HSM Dunavant LLC 1930 Abbott Street, Suite 403 Charlotte, NC 28203 ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director Subject: Permit No. WQ0039390 HSM Dunavant LLC Dunavant Townhomes Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. McCollum: In accordance with your application received August 3, 2017, we are forwarding herewith Permit No. WQ0039390 dated August 7, 2017, to HSM Dunavant LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered _a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be. automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of•the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request anadjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. w` Nothing Compares State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704-663-1699 If you need additional information concerning this matter, please contact Barry Love a or via e-mail at barry.love@ncdenr.gov. Sincerely, by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Mason L. Greeson, P.E. (e-copy) Barbara Gross (e-copy) Tommy Rowland (e-copy) Regional Office Files Water Resources Central Files PERCS (e-copy) 7 2143 2 Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter. 143, General Statutes of North Carolina as amended, and other applicable Laws; Rules, and Regulations, permission is hereby granted to HSM Dunavant LLC Mecklenburg County for the construction and operation of approximately 284 linear feet of 6-inch gravity sewer, to serve the Dunavant Townhomes project, and the discharge of 3,800 gallons per day of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received August 3, 2017, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's .Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0039390 Permit Issued: August 7, 2017 3 SUPPLEMENT TO PERMIT COVER SHEET HSM Dunavant LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water Irwin [reek Wastewater Treatment Plant in accordance with Permit Number NCO024945. Permitting of this project does not constitute an acceptance of any part of the projectthat does not meet 164 NCA[ 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Caroli n a- licensed Professional Engineer in the application, It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation \scontingent upon compliance with the Standard Conditions and any Special Conditions identified below. |. SPECIAL CONDITIONS 1. No flow in excess of the quantity permitted herein, 3,800 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted toand approved bythe Division. (lSANCAC03T.03O4/b\] 2. This permit shall become voidable unless the agreement between HSM Dunavant LLC and Charlotte VVa&ar for the collection and final treatment of wastewater is in full force and effect. [15A N[AC 3. The Operational Agreement between the Permittee and the Environmental Management Commission isincorporated herein byreference and shall beacondition ofthis permit. Noncompliance with the terms of the Operational Agreement shall subject the Pernnittee to all sanctions provided by North Carolina General Statutes §143'J15.6Ato§143'315.6Cfor violation oforfailure toact inaccordance with the terms and conditions ofthis permit. [1SANCACOZT.Q11S] Ill. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Pemmh1ee, a fPnna| permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials asmay beappropriate. The approval ofthis request shall beconsidered on its merits and may o,may not beapproved. /16ANCACQZT.01Q4|G.S143-21S.1(d3)l 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions ofthis permit; lSANCAC 2T;the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 199G,a5applicable; the Division's Minimum Design Criteria for 4 the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [1SA NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shalt be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. 5 Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (I) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. S. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(al.)) 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are 6 I marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis, If a portable power source or pump is dedicated to.multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. 'Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope perthe Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with.firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by his Division, such as the construction of additional or replacement facilities. 115A NCAC 02T .0110; 1SA NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be equired by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)1 I FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: _ PERMIT #: PROJECT: ISSUE DATE: HSM Dunavant LLC WQ0039390 Dunavant Townhomes August 7, 2017 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, n weekly, ❑ full time). the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final D Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina I Environmental Quality 1 Water Resources I Water Quality Regional Operations Mooresville Regional Office] 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 STATE OF NORTH CAROLINA COUNTY OF Pennit No. W0003g39 t5 DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S.`143-215.1 (d1) and entered" into this jY 5 • day of 7)4 - •` , by and between the North Carolina Environmental Management Commissions an agency of the State of North Carolina, hereinafter known as the COMMISSION; and HSM Dunavant LLC , a corporation/general partnership registered/licensed to do business hi the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the.certain lands lying in Mecklenburg County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known . rDunavant Townhomes : (hereinafter the'Development). 2. The DEVELOPER desires, to construct a wastewater collection system withpumps, wastewater treatment Works, and/or disposal facilities (hereinafterDisposal System)' to provide sanitarysewage disposal to serve the Development on said. lands. 3 . The DEVELOPER has applied to the COMMISSION for the issuance,ofa permit pursuant to, _G.S. 143- y215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings Units; other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration),..pursuant,to Chapter 47C or 47F of the North Carolina General Statutes. • 5. The DEVELOPER 'has caused to be `foriiiedor Will cause to be formed at the time of filing of the Declaration, the (Dunavant Townhomes 1HOA) . (hereinafter Association), a non-profit corporation organized and existing under and by the .virtue of the.iaws of the State Hof North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining;°re-constructing and repairing the common elements of,the lands and improvements subject to .unit ownership, including 'the Disposal System; and of collecting dues 'and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. ` The COMMISSION desires to assure that -the Disposal System of the Development is properly constructed, maintained and operated' in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE,' in .consideration of the promises and the benefits to be derived by'each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct -the Disposal System in. accordance with the permit and plansand specifications hereafter :issued and, approved by the COMMISSION, and shall. thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and,law..L ,- a 2: -- The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been_completed'in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the naive of the permit holder, the DEVELOPER must request that; the permit be reissued to the Association. The request must include a copy'of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its,responsibility for the operation and maintenance of its, Disposal System until a permit has been reissued to the DEVELOPER's successor. FORM: DEV 08-13 Page 1 of 2 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5, The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEN/ELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. I O. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL Revolve Residential MANAGEMENT COMMISSION Name of DEVELOPO-- ----- By: S. Jay Zimme an, P.G. Director, Division of Water Resources A (Signature) 71 Print Namtand Tit (Date) (Date FORM: DEV 08-13 Page 2 of 2 August 2, 2017 Dunavant Townhomes LDI Project No. 1016297 SEWER SYSTEM APPLICANT: EISM Dunavant LLC 1930 Abbott Street Suite 403 Charlotte, NC 28203 DEVELOPER: Revolve Residential 1600 Camden Road Charlotte, NC 28203 DESCRIPTION: The site consists of approximately 0.55 acres. The property is zoned TOD-M and will consist of 20 townhomes. We are proposing to install approximately 284 if of 6" PVC sanitary sewer main on -site that will make up the private system. SEWER SYSTEM IMPROVEMENTS: The proposed demand for this site will be approximately 3,800 gallons per day. The demand is based on 20 units at 190 gallons per day/ unit. New mains are expected to have a minimum 50-year service life. The system will be constructed by the Developer and services will be billed by the City of Charlotte in accordance with their standard rate schedule. N3 2©16\10162971 IT'i'INGIPERMIT FORMSISEYNER416297-NARRA.TIWEDoC LANDDESIGN, INC, Division of tdatd r Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02"1' .0300 — F AST TRACK SEWER SYSTEM STEM EXTENSION APPLICATION FTA 0-1-1( & SUPPORTING DOCUMENTATION All items APPLICANT INFORMATION: 1. Apphcattit" rtdartre: ISM D mat astd Applicant t'pc. Individual Q Federal me: "hi in rthr State: 1WC° Applicant', eontc.ct arrfd}r�nation, Plume number: (04) 965-25335 PROJECT INFORMATION: 1. Pro] homc,s. ApplicadtionfProleet status: If a modil`ication, provide tltc c;istinl Numb met ustbe completed or the J!li ation' ill he rcturne lu "address: Proposed (Neer Pcdn7it) crrrtit datrittbr.r'° W Q((O 11 new construction but part of a miter plan, provide 3, i °r dattl ` \ here project is located: Mecklenburg d. ^' pproxirt atc Coo r°c: mates (Decimal Degrees). Latitude: 3 5. Parcel ID (if applicable): 11_ I (:) I7..13 (or Parcel 11) to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional luntgincei Tv€vt, atd u Finn. LandDcsi a_, .� MMailingaic:I[C'i;Sti'. 3 N C7d"a .n�_ City: (lt<ti'lc?ttcd Stalt.dv' NC Ph asidcntial.com se Number 04316 ©li ercesont'u;lsdndd.s jn.e WASTEWATER TREATM ET FAC:ILI"I' (WWTF) INFORMATION: _Name: Irwin .reek. Wa-tewater'I'acatnien( Mani Permit Number: N O((24 )45 r Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (ii'tlifferent than WWTF): 1. Permit Ntmnbcr(s): WQ„____. stem Wide Names): stream. (Receiving) c. •ei Sire: _ inch 04-1(i THE COMPLETED APPLICATION PACKAGE INCL.DING ALL SUPPORTING INFORMAT'ION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIO AI OFI'I REGIONAL OFFICE Asheville Regional Office ater Quality Section Fayetteville Re, Water Quartty ffice ADDRESS COUNTIES SERVED 2890 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell Cherokee, Clay, Graham, Haywood, Henderson„ Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey 2'25 Green Street Suite 714 Fayetteville, North Carolina 2830'1-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland lie Regional ality Section 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union aleigh Rerronal !ffice Quality Section hington Regional Office ual'ity Seetican ingtonRegional 0 r islu^a�ity Set(n 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax 943 Washington Square Mail Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax,, Johnston, Lee, Nash, Northampton, ©range, Person, Vance, Wake, Warren, Wilson Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pander Winston Salem Region Water Quality Section 450 W. Hanes Mill Road Suite 300 Winston-Salem North Carolina 27105 (336) 776-980ft Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin INS RUCTiC)N5 t ft1 f'"f)I I is 1' 1'r 04 `lNC DO( t. MI N`1A1`1(_)N Page 3 <l'3 VI. GENERA L REQUIJE:1 TENTS I . lithe Applicant issr E'rir`ti� Caw ,eloper approved under pi of flow redu Esfalalishrncn t ', "v pe Per 15A NCI\C 021 .it1l�llcaJ, (lest be determined usan aaati11171e lleaww° ll Wastewater generated by protect.: I)a not include futua where flow it Nutrib- -epar1tiian' crw'icc / dental / r•'etel inaliv F r litir ial e `us tr.°c)nuncre ial 20 ),p Elfin et I'leffect? El Yes No Yes Ni nd Ne -e Wash and/or Motels Miming fool /Clubhouse ,kwash idled? ident and other measured data, 04-16 VII. GRAVITY SE » r"E R DES I sN CRITERIA (If A.pplixahle) . Summarize grayi Section 11 t4. 191 of Section 111 contains irtforn Oversiiing lines to meet minimum ,slope requirement is not allowed and a r1otation o VI[I. PUMP STATION DESIGN CRITERIA (If Applicable) 0I; 0305 & Ill ?t.�F'u� a,I� �1 Nlaots ly :. COMPLETE I�OREACH.PUMP STATION INCLUDED 'IINTIlI' PROJECT I . Putnp .station number or name: Approximiatet.",oc. Deg s9. l.tatiitidt. .on itne:l ; 3. Design flow of the pump station: �1. C )rezattit�inal l o hat(s;( "the purnp(s): galleons. per n in to be porn POvVcr n accordance with I 'ziA N © Standbv" ilt storage t'a)'rac; prov r pump lk°t )2IT e daily flow greater n average daily flow less tlian I.5,(i()i4 galleons per daw k ceotitie. tiaaia ieceptacic and tc gency pununp eoa&ttaei tiiata iiiid ti ltiticeta' I NCj\C 021 .0305h1(111C): ed to the Division that the portable source is owned or contracted hti the applicant (el. with the station, d the rotation schedule at` th en1) Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & I.5A ISCAC 02T .0305 (17)): L Does the project comply With all separations found in NCA.0 02T .t.i305(1) & • 15A NCAC 02T,0305(I) contains minimum separations that shall be provided for sew T systems: Se back Parametet* StOrtn SeWers and other utilities not listed below ("vertical, Yes 0 No Separation Required 24 inches Water Mains (vertical -water over SCWer including in benched trenches) 18 inches / feet Water mains (horizontal') Reclaimed Water lines (vertical - reclaimed over sewer) Reclaimed water lines (horizontal - reclaimed over sewer) **Any private or public \Vat er suppl\. source, including any wells, WS-l. waters of Class I or Class It -iounded reservoirs used as a source of drinking water **Waters classified. WS (except .WS-I or WS- V), 13, SA, OR.W, HQW, or SH from normal high water (or tide elevation) and Wetlands (see item IX, 2) 18 inches 2 feet I 00 feet. 50 feet *Any other stream, lake, impoundment., or ground water lowering and surface drainage ditches \it buId1nt loundation Any brisement op slope ofei feet ui of 2 feet or .noie vertical height Drainage systems and iritcrceptor drains Any SWiturning pools . eat lt mad vcttie.il feet 10 feet )0 feet 5 feet 10 feet 36 inches 15A NCAC11 l contains alternatives where scriirat ions in 0.2T.0305( I) cannot he achieved.. • "Stream ela.ssifications can be identified using the Division's NC Surface \Water Chissifio.titions .)voLvig), If noncompliance with 02.T.0305(1) or see Section x or (his applicatnm Does the project comply With Separation requirements for wetlands? (50 feet of separation) 0 Yes E3 No N/A See the Division's draft separation requirements for situations NAllere separation. cannot be meet No valiance is required if the altermitive design orite.ria specified is utilized in design and construction As built documents should rof erence the :locaton of areas effected 3 Does .the project comply with setbacks found in the river basin rules per 1.5.A 021 .0200? 0 Yes 0 No NA • This Would include Trout Buffered Streams per ISA. NCiVI: 2110.202 4. Does the project require. coveragelauthorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? • Information can he ()blamed from the. :401 & Huffef Li Yes No 5. Does project count ith 15,A NC.A.C" 02T.0 OSi:c y 6) (additional penmisfeertiliea Lions)? Ye j No Per I 5A N(2AC 021 0105(c )( 6 ), directly related environinciit al permits or certification 'ippl-ications are being prepared, have been applied for or have been obtained, Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, storm water management plans, etc). Does this project include any Sewer collection lines that are deemed '-high-priori Ey?" Per 1.5A NC/\ 02T.0-102, "high -priority SeWer' oilcans an aerial sewer, sewer contacting. surface waters, siphon, or Sealer positioned parallel to sireambanks that :is subject to erosion that undermines or deteriorates the sewer, 0 Yes 0 No .N/A If ves, includean attachment 00 details for each Inc includi -g„ type (aerial line, size... -.a' eriat .n',1:nd. location). High pr.ior.ity lines shall be inspected by the permitted or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: 1T A N- I 6 Page 4 (115 X. CERTIFICA`f"IONS: Does the subITil and 1_tUee,il _ ad system Corn it est very➢a t'al Yes If No,, conallete aaracl satbttait the Variance/Alternative 1)esit for retie' AJ?Pr t a _.of thereqnest is required _prior docurnertts. angineea's (ci of my knowledge Minimum Design Permitting of Puna. Stations anc portions of this submittal package, inc material and have judged it to be consistent 1a has been No ctlliest aplalieaati subinitta of ti pl (VAi)C 10-14 ) and supporting ddaa Fast Track Application and sup n,entaticarl to etas taest cat ntr` 1 p<arcd in accordance “it th steasionl, and the Mumn °c ionl. Although otla a' lot " these mate NOTE — in accordance with General Statutes 1.43-2 statement„ representation, or certification in any application include is fine not to exceed' 10,000as well as civil penalties 143-215.613. lcktage shall be gm $25.t North Carolina, Professional Engineer's seal, signature, and date: Applicants Certification per lSA NCAC. this ap aappilcat discharge s, I niunCt1\'C. 0. nd is accurate and subject to bean andior Crinin: condition of this permit be violated. 1 also an and that if all required supporting me as incomplete. NOTE — Itt accorclattec ttith General St statement, representation, car certification include a line not to e\cecd Sldl, nd seal signifies knowledge, sail required supporting doeutaacnt;ati+ d is incomplete. I wadeistand that at \\ill restalt itt an inanledi tee enl'iireCJTU t .x.-tat re7:at,-.y �ssa raraxxa'e arisarxr«.t atn✓ that nd aatlatchments are not iz Pena he guilty leer violation, licatio lans, s that to the best Kis, Gravity Sewer ar the 1'aast-`Track. developed certain ve reviewed this \\ho knowingly ingly makes an_ 2 naisdenlca SEAL 043168 FWGINE 2.I 1? pplication for 1 understand that if aa'll rcluired parts of and attachments are tool, included, tlaisw discharge of wastewater from this non- icalt that may/ include civil penalties, Water l esotarecs should as apficaatiott package are not completed 1pplication paekaage will be t'ulilled to vingi\ makes any false A 0.:1-1(' Page. 5 of 5 CHARLOTTE W TER March 9, 2017 Mr. Frank McMahan LandDesign, Inc.. 223 North Graham St Charlotte, NC 28202 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE DUNAVANT STREET TOWNHOMES 2418 DUNAVANT STREET, CHARLOTTE NC CLTWATER TRACKING# 20161544 After an analysis of the sanitary sewer associated with the proposed design of project Dunavant Street Townhomes, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 3,800 gallons per day (20 townhorne units x 190 gpd/unit) at the connection point(s) indicated on the submitted utility plan for transmission to the Irwin Creek Wastewater Treatment Plant; NPOES permit number NC0024945, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatment works. Please see attached FTSE form, CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. CLTWater does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water and sewer systems, as the appropriate local or State permits are required prior to construction, if the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acceptance letter; and payment for any service connection(s) has not been received within (1) year of issuance of this flow acceptance letter, this flow acceptance approval shall be rescinded and a new flow acce ta nce :stu d must be made. if you have any questions, you may contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant Char! tte Water 5100 en okshire Bevrj, C17ariotr , NC 2g116 charkt Operated by the City of Charlotte IS>1 �.ra r M/xt h. rsai.�M State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: LandDesign, Inc. Project Name for which flow is being requested: Dunavant Street Townhomes More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTPFacilityPermit#: NC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 99.0 13.380 70.717 0.0038 84.101 85.0% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm - Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pir), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can he achieved with the Largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Dunavant Street (1957) Downstream Permit Number: unknown Page 1 of 6 FTSE 0446 III. Certification Statement: J _ Carl Wilson _ _ certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing O.ir1 Signature Page 2 of 6 6110 ate FTSE 04- 16 7/21/2017 USA Topo ps ArcGIS - USA Topo Maps This layer presents detailed USGS topographic maps for the United States at multiple scales. Copyright: C3 2013 National Geographic Society, 'i-cubed City of Charlotte, State of North Carolina DOT, Esri, HERE, Garmin, INCREMENT P, Intermap, USGS, EPA, USDA https;//www.arcg s.corm/homelwebmap/printhtml 1/1 Corporations Division Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY of STATE PO Box 29622 Raleigh,NC 27626-0622 (919)814-5400 Click Here To: View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre -Populated Annual Report form Corporate Names Account Login Create Site Account Legal: HSM Dunavant, LLC Limited Liability Company Information Sosld: 1555237 Status: Current -Active Annual Report Status: Current Citizenship: Domestic Date Formed: 11/16/2016 Fiscal Month: January Registered Agent: McCollum Advisors, Incorporated Corporate Addresses Reg Office: Reg Mailing: 1930 Abbott Street Suite 403 Charlotte, NC 28203 1930 Abbott Street Suite 403 Charlotte, NC 28203 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. https://www.sosnc.gov/Search/profcorp/12470006 8/3/2017 NortE T nst°. a.. a 1016297 DUNAVANT 8/2/201 474 TOWNHOMES-REVOLVE RESIDENTIAL 1016297 su` = x : Dunavant Townhomes Fast Track Sewer Permit Package PURPOSE: For your approval FROM Mason Greeson 223 North Graham Street Charlotte, NC 28202 Barry Love 610 E Center Ave #301 I NCDENR - Room # 3323 I Mooresville Regiona Mooresville NC 28115 I Office United States I ANDDESIGN INC. RE MARKS 00007 Second Day „NC jr"NROVVR OR € ' E F 3, t i SCE anddesign,com 704 barry.love@ncdenr.gov Please find a Fast Track Sewer permit application package for private sewer to serve Dunavant Townhomes in Charlotte, NC. If you have any questions or concerns, please feel free to call me. Thanks, Senior Associate J Charlotte l (o) 704,333.0325 Charlotte A andDesign nc Central Files: APS _ SWP 8/7/2017 Permit Number WQ0039390 Permit Tracking Slip Program Category Status Project Type . Non -discharge Active New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions 1.00 Individual Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 3,800 Facility Permit Contact Affiliation Facility Name Dunavant Townhomes Location Address Owner MajorlMinor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Hsm Dunavant LLC Dates/Events Owner Type Non-Govemment Owner Affiliation Tim McCollum 1930 Abbott St Charlotte NC 28203 Orig Issue 8/7/2017 App Received Draft Initiated 81312017 Scheduled Issuance Public Notice Issue Effective Expiration 8/7/2017 8/7/2017 Regulated Activities Requested /Received Events Subdivision Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin FAST TRACK 5 EFt ENIfEEItIN PERMIT -TEE: -SM Dunav, l t L,1C PERMIT St. PROJECT Duna- , nt Townho ISSUE DATE: August '7w 2,017 proem shall not be con aerrnit until the Divlsron rid be submitted in a manner that d{o; omen%, t e Dijivisjonrsreceipt, CATION ordancer with CCcndition 7 of upportingg bocurner'rtat ci dray.:r°rlr'iw Stupksrvetior,'Water Quality Regional Operations' Section at the address at the boil er flow made tributary appropriate en, until a flna, cert,il':i design caiculiations o t dl„ss s'bat be considered a violati ent actions. The Permittee s d, A Final Cert hca :r egard'.css o or to consoletarn ermittrve to r°tia6 r:c rtif€cations up e a cemdiete tet ol. record dravw rgs and rn?ttt,'d. PrRNUTT E' C RTIFt 14'rION ur`1+certig`te"a„t agent for the Permittee, het° IN state e. applicable standards 8 sequ,rernents. Profes nai E. rrconstruci.ion 'information to the Perr mace, and the Perrrtitt collection system permitted herein er portions thr,reof, Printesct Name, rEt! ENO T3 l 'A t tN hsavin project name and location as rs erenc boven for the abrav rny abli fe ta;. due care and diligence was used in the observation of the construct to was observed to be built within s,ubstanttai compliance of Division of fir+ag,er" Resources` €Oiviroonl t r a a"cw€,r Minimum Design Crit construe s provided :pared to operate 1996, 'A applfdabble;; to DWiStiorr 5 f irtirn aw gn iteria t R'thE Fast Track p s adopted runa:.t 1, 2000, as re)ITl licabie; and othc:r s arolina Profess=o!°r,yl E,ar,p,'r ear- s Seal wfs,fw"sattilt"t & date. Partial (include description) C•ertffic, tion Corrmrrfents/Qualifiers (attach it necessary}: f North Carcl slap ucbon of the > tt e hest of construction such that the mit,; 15A NC,A.0 021; the opted Feb t)oi I , Irt inn Station ,rails October 2, 2018 State of North Carolina. Department of Environmental and Natural Resources 61€0 East Center Ave, Suite 301 Mooresville, NC 28115 Re: Sanitary Sewer Certification Dunavant Townhomes Mecklenburg County Permit Number: WQ0039390 LandDesign PN: 1016297 To whom it may concern, On behalf of Revolve Residential, we are providing herewith inspection reports, as built survey, and a final certification for the Wastewater Collection System to serve Dunavant Townhomes, located in Charlotte, NC, This final certification package is being submitted to certify the construction and completion of the Duavant Townhomes sanitary sewer collection system under the fast track permit number WQ0039394, The project consisted of approximately 284 of 6" PVC gravity sewer. Construction of this system was observed and built within compliance of the permit,. Feel free to give me a call it you have any questions. Respectfully Subm Mason L. Greeon, PE Senior Associate LandDes'ign, Inc, Enclosures 1016297 DUNAVANT TOWNHOMES-REVOLVE RESIDENTIAL 1016297 Dunavant Townhomes Sanitary Sewer Certification For your approval Maxwell Grogan EMAIL MGrogan Tans tat 10/12/2018 00010 moop 4 :� Mail nddesign.com Barry Love 610 E Center Ave #301 NCDENR o Room # 3323 Mooresville Regional barry.iove@nedenr.gov Mooresville NC 28115 Office United States Barry, Please find the enclosed Final Sanitary Sewer Certification package for Dunavant Townhomes. We have also sent you a electronic copy via email for your use. Let us know if you have any questions or may need additiona information, Thank you, Max MAX GROGAN, PE, LEED Green Associate Designer l Charlotte I (o) 704,333.0325 Charlotte I Washington DC Dallas l Orlando C San Francisco i t3milder @Landaesigninc Mason Greeson (LANDDESIGN INC.) • .FoL.R.�d_ � .•.. :'�• F�:. f'ul:•. d0: :•!": 1 '. 4A. FIELD REPORT Project: Dunavant Townhomes Weather: Clear Location: Charlotte, NC Present at Site: William Morris-LDI Date: January 4, 2018 LandDesign PN: 1016297 Contractor: Total Time: CC: Comments: • I was on site today to observe the test on the sewer line and to look at the installed line before it is backflled. • The entire sewer line has been installed and was pressurized to 4 psi. The line was held for 5 minutes with no sign of pressure loss. The pressure test passed. • The contractor was installing the tracer wire on the laterals today while I was on site. The wire has already been installed on the main trunk line. • Ail installation looked good and the contractor is free to backfill. Signed: **See attached pictures. /4.1_4 William Moms LandDesign, Inc. •.•,)•F?..•,, cGk "�is....res. „ i�i ;+. �(s "> il` ;n..� .. .�. ,:..�. .... otv .j. ;h",e,) •,t 7n; .0..y.7, 7 .'4 ;,,