Loading...
HomeMy WebLinkAboutWQ0037950_Regional Office Historical File Pre 2018North Carolina Depa Pat McCrory Governor C E of Environment and Natural Resources August 17, 2015 Ms. Peggy Hey, Executive Director of Facility Planning and Management Charlotte -Mecklenburg Schools 3301 Stafford Drive Charlotte, NC 28208 Subject: Permit No.WQ0037950 JM Alexander Middle School Wastewater Collection System Extension Permit Mecklenburg County Dear Ms. Hey: Donald R. van der Vaart Secretary In accordance with your application received August 5, 2015, we are forwarding herewith Permit No.WQ0037950 dated August 17, 2015, to Charlotte -Mecklenburg Schools (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board.. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Mooresville Regional office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1699 \ Fax 704-663-6040 \ Customer Service 1-877-623-6748 Internet: www,ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer — Made in part by recycled paper Charlotte -Mecklenburg Schools Permit No,WQ0037950 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov, Sincerely, for S. Jay Zimmerman, P.G, Director, Division of Water Resources, NCDENR by Michael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDENR cc: Kevin J. Westra, P.E. (electronic copy) Barbara Gross (electronic copy) Tommy Rowland (electronic copy) Regional Office Files Water Resources Central Files PERCS (electronic copy) Page 2 of 8 NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Charlotte -Mecklenburg Schools Mecklenburg County for the construction and operation of approximately 548 linear feet of 8-inch gravity sewer to serve a 1200 student school as part of the JM Alexander Middle School project, and the discharge of 18,000 GPD of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received August 5, 2015, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the cified conditions and limitations contained therein. for S. Jay Zimmerman, P.G. Director, Division of Water Resources, NCDENR By Authority of The Environmental Management Commission Permit Number: WQ0037950 Permit Issued: August 17, 2015 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Charlotte -Mecklenburg Schools is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McDowell Creek Wastewater Treatment Facility in accordance with Permit Number NC0036277. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum. Design Criteria adopted March 4, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS This permit shall become voidable unless the agreement between Charlotte -Mecklenburg Schools and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. (15A NCAC 02T.0304(h)] 2. No flow in excess of the quantity permitted herein, 18,000 GPD shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] I1. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215J(d3)] This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 021' 0110] This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. (15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual systemwide collection system permit for the Page 4 of 8 operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shalt be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows:. 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures, of pumps, line blockage orbreakage, etc.;or L Any SSQand/or spill over 1,0OUgallons; or c. Any SS8and/or spill, regardless ofvolume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal oeport. Overflows and spills occurring outside normal business hours may also be reported to the Division ofEmergency Management attelephone number /800\ 058-0368or(919) 733'3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part l of Form CS-SSO (or the most current Division approved form) within five days following first knowledge ofthe occurrence, This report must outline the actions taken orproposed tubetaken toensure that the problem does not recur, Part ||nfForm CS-558(or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.3. I43' G. Construction of the gravity sewers, pump stations, and force mains shall he scheduled au as not to interrupt service by the existing utilities nor result in an overflow nr bypass discharge of wastewater tothe surface waters mfthe State. [15ANCACO2T.0108<b\] 7. Upon completion m[construction and prior ozoperation mfdhesepennittedfacj0ties the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tuthe address provided mnthe form. Acomplete certification isone where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the PermitteetVappropriate enforcement actions, If the permit isissued toaprivate entity with moOperational Agreement, then ocopy of the Articles of Incorporation, [eclaratio ns/Covena'ts/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register mfDeeds office shall besubmitted with the certification. Acomp|e{e certification |yone where the form is 6u|k/ executed and the supporting documents are provided asapplicable. Supporting documentation shall include the following: a. One copy ofthe project construction record drawings (plan & profile views Of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVDdlsk) and are defined asthe design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b^ One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability toflush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If portable pmm/cr source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframe4shall beprovided. Page 6 of 8 c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be dearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by. the Division and may not be approved, thus requiring replacement or repair prior to certification & activation..[15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. if there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. j 15A NCAC 02T,0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including. those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S.143-215.1(b)] Page7of8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTE2: PERMIT #: PROJECT: ISSUE DATE: Charlotte -Mecklenburg Schools WQ00379SO ]KAAlexander Middle School August l7,38l5 This project shall not beconsidered complete nor allowed to operate inaccordance with Condition 7of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Super -visor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until afinal certification isreceived, AFinal Certification shall beacomplete set nfrecord drawings and design calculations regardless of whether partials have been submitted. PERM qCATION U, the undersigned agent for the Pennktee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information tothe Pennittwe,and the Pernohtee is prepared to operate 8'maintain the wastewater collection system permitted herein orportions thereof, Printed Name, Title Signature Date ENGINEER'S CERTIFICATION [ , as a duly registered Professional E neerin the State ofNorth Carolina, having been authorized to observe U } periodically, . wewkky, 1 | h/|| time) the construction of the project name and location asreferenced above for the above Pcrnmittec hereby state that, to¢he best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A N[ACOZT; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date. rlFhna| | JPartial (includedescription) Certification Comments/Qualifiers if : N[DvVR—Water Quality Regional Operations Section 6l0East Center Avenue, Suite 3O1,Mooresville, mC2n1I5 z z 0 z 3301 Stafford Drive Mailing Address North Carolina State h, 980-343--6050 Telephone USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Owner/Perrnittee: Charlotte -Mecklenburg Schools _ Full Legal Name (company, municipality, HOA, until (€1,-Atri e and Title (Please review 1 5A iC Application Number: (to be completed by DWR) (cVt� Wt%V"l authorized 'gning officials) The legal entity who will own this system © Individual 0 Federal 0 Municipality ® State/County 0 Private Partnership 0 Corporation 0 Other (specify): Charlotte 980-343-5200 Facsimile Protect (Facilit3r) Information: Alexander Middle Sr:o of Project Name (p contact. Person: Brian J. Cannella- Benesch o this name Name and Affiliation of Someone Who Can Answer 3b. 704-943-3173 Phone Number Project is New L Modification City g. 28208 Zip Code E-mail WQROS 2b, Mecklenburg MOORES IL F REGIONAL OFFdCEI County Where Project is Located uestions Abou of an existing perm Owner is 0 Public (skip to Item 8(3)) this Application 3c, bcannella@benesch.corn E-mail If Modification, Permit No Private (go to Item 2(a)) 2a. If private, applicant will be: Z Retaining Ownership (i.e, store, church, single office, etc 0 Leasing units (lots, townhomes, etc, - skip to item B(3)) 0 Selling units (lots, townhomes. etc, - go to item B(2b)) Charlotte -Mecklenburg Utili Department Owner of Wastewater Treatment Faci y da, McDowell Creek Wastewater Treatment Plant Name of WWTF a Charlotte -Mecklenburg Utilities5b, 8"" Z Gravity ner of Downstream Sewer Receiving Sewer Size Ell Force Main The origin of this wastewater is (check all that apply): 2b. If sold, facilities owned by a (must choose one) or 0 Public Utility (Instruction D} 0 Homeowner Assoc /Developer (Instruction E) F) Treating Wastewater From This Project 4b, NC0036277 WWTF Permit No.. 5c. nla ] Residential Subdivision © ApartmentslCondominiurns 0 Mobile Home Park School 0 Restaurant 0 Office Permit # of Downstream Sewer (Instruction F) Retail (Stores, shopping centers) Institution 0 Hospital 0 Church 0 Nursing Home 0 Other (specify) Volume of wastewater to be allocated or permitted for this particular project. 18,000 *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 5A _N , v)!u2 ,0303 to determine if a permit is required) 100 % Domestic/Commercial % Industrial (Attach Description) ° , Other (Attach Description) gallons per day ETA 08 13 APPLICAT[C)N Pa e 4 of 6 I IPLETED A.PrL'CATION PACKAGE rsiCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE Asheville e R ~gional Office Water Quality Section ADDRESS Fayetteville Regional Office Water Quality Section Mooresville Regional Office Water Quality Section Raleigh Regional Office Water Quality Section Washington Regional Office Water Quality Section ington Regional Office Quality Section 2090 US Highw 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax 225 Green Street Suite 714 Fayetteville, North Carolina 28301-50 (910) 433-3300 (910) 486-0707 Fax 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax nston-Salem Regional Office Ater Quality Section 943 Washington Square Mall Washington„ North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax 27 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Waughtown Street inston--Salem, North Carolina 27107 6) 771-5000 6) 771-4630 Fax COUNTIES SERVED Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Anson, Bladen, Cumberland, Harnett, Hoke„ Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Alexander, Cabarws, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Chatham, Durham, Edgecombe, Franklin„ Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Brunswick, Carteret, Columbus, Duplin, New Hanover, Onsiow, Fender Alamance, Alleghany, Ashe, Caswell, Davidson Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin INSTRI..JCTIO, OR APPLICAHON ETA 08-13 & SL.IPPORTING DOCUMENTATION 3of6 Pri;rovide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 ford the value in Item 8(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). Daily Flow Demand for Schools = 15 gallons/student/day; Number of Students = 1200 Total Wastewater Flow = 15 gallons/student/day x 1200 students = 18,000 gallons per day (gpd) J 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) I New Gravity or Additional Size (inches) Length (feet) ; Force Main 8 548 Gravity 11. Summary of Pump Stations w! associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: • .•• 1 , Design .Flow 'F Power.Reliab_ ility Option i• r (MGD) Operational Point'+1 - permanent generator w/ATS; Force Main Size i 4Force Main Length GPM @TDH 2 - portable generator w/MTS ' • • Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow Power Reliability Option (MGD) Operational Point 1 - permanent generator w/ATS; Force Main Size Force Main Length • GPM @TDH 2 - portable generator w/MTS 12. • (RO Will Yes — if the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ►Z� No If Yes, permit number of 2nd treatment facility : "yes" to 8,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ' / . Yes 'D No if No, please reference the pertinent minimum design criteria or regulation and indicate why a • variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS . PERTINENT TO THE VARIANCE WITH YOUR APPLICATION i FTA 08-13 APPLICATION Page 5 of 6 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No N/A Sedimentation and Erosion Control Plan? 9 Yes ❑ No ❑ N/A Trout Buffer Waiver? ❑ Yes ❑ No N/A Stormwater? 1 Yes ❑ No ❑ N/A 5, Does this project include any high priority lines (15A NCAC 2a .d.9402 (2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months heck if Yes: ❑ and provide details: e's Certification: (Signature of Signing Official and Project Name) ttest that this application for JM Alexander Middle School) has been .reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that quired supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.60 any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 15 Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY Z TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T 0305 0 2, Professional Engineers Certification: (Signature of Design Engineer and Project Name) 1, Kevin J Westra ,attest that this application for Jrn Alexander Middle Schaoll has been reviewed by me and is accurate„ complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge_ 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies .that i have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6,A and 143-215, 8, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 2a. Kevin J. Westra Professional Engineer Name 2b, Alfred Benesch & Company Engineering Firm 2c. 2820 West Morehead Stree Mailing Address 2d, Charlotte City 2e. NC 2f, 28208 State Zip 2g, 704; 521-9880 2h. 794-521-8955 2i. kwestra@benesch.com Telephone Facsimile E-mail E°TA 08-I.3 APPLICATION 6 of 6 CHARLOTTE W May 1, 2015 Mr. Kevin Westra Alfred Benesch & Company 2320 W Morehead St, Charlotte, NC 28208 TER SUBJECT: WATER AND SEWER FLOW ACCEPTANCE JM ALEXANDER MIDDLE SCHOOL PARCELID# 017-051-12 C-MUD TRACKING# 600-14-531 A flow acceptance study of the subject site has been completed and it has been determined that Charlotte -Mecklenburg Utility Department (C-MUD) agrees to accept the gravity sewage flow of 18,000 gallons per day (1,200 student Middle School with Cafeteria and Gym x 15 gpd/student) from this project for transmission to the McDowell Creek Wastewater Treatment Plant; NPDES permit number NC00036277, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see attached NCDENR Flow Tracking form, C-MUD agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 016001,0 on file with the Public Water Supply Section of NCDENR. However, C-MUD cannot guarantee a constant pressure or quality of flow. C-MUD does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MUD system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction, if the appropriate authorization to construct errtit ire not obtained and construction has not started within on f 1) year of the issuance of this flow acceptance, this flow acceptance approval shall be rescinded and a new flow acceptance study must be made, If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant Page 1 of 1 Charlotte Water 700 N. T8Wc`}t';; : tlI,'tll $Et'; NC 28202 chat1ottewater.oc, V' Operated by theicy. d bar tt North Cardlina Department of Environment and 'atural Resources Division of Water Resources ink;/Acceptance for Sewer Extension Applications VISE 08-13) Project Applicant Nan Project Name for i ore than one l ;"h r tuft its cliong the route o eing requested: Jr Al, aracer Mid ci.le ,rus de pr't the owner of the WWII' is nor re Complete this secicat onl, a. V1""1NI P Facility Name: b. WWTP Facility Permit 'it: you are the owner olthe wastewater treatment plant. of yet tributary to the c, ` ` '"f'E f`aat Uit ,s actual av'ar,,. flow specific reel.tes g, °lc taq .aett,t£aq and obligated f h. Percent of permitted flow used 0a50,7 Complete this se proposed wastewate t pump stations located between the pro ect connection point and the W"W'TP: Pump Station (Nance or Number) pump slat you are responsible for akmg the route of this (A) Design Average Daily AAppro ,. Flow** `urrent Avg. (Firm pt),. N1Cr.) (H) 1:t w Plus '.gated Flow The 'P:irna (rapacity of and pump station is defined as _._ . _..._ .w. * the maxi pumped klow that can he achieved with the largest pump taken out of service. *'* Design Average Dailey Flow is the firm capacity of the purnp station divided by a peaking factor (pf) not less than 2.5. **' A Manning Assessment Addendum shall he attached for each pump station l caned between the project connection point and the WWI' where the Available Capacity is <(1. the vc I _ the best of my know le tf aft the addition ,tmtc.tOtre receiv ticipated to cause an rm pump station en route tc the receivinye treatment plant under na`.�rt tai circtmrtm tartcea. ;i xen the irnpiementation of the planet cd improvements identified in the planassessment here applicable. This analysis Imas beema performed in accordance with local established policies and proct the best available, data* Thiti certification applies to those items fisted above in Section; plus all attached planning assessment addendums for which. I am the responsib Signature f this ft rt t indicates acceptance of this wastewater flow, end II party. Other enesch en sdetltt“s eerortnee$ Transmittal Form To: �NCDENR Water Quality Section Mooresville Regional Office 610 E. Center Ave Mooresville, NC 28115 N(.UENR DWR WO, fOS MOOR V t,„L µ REGIONAL OFFICE Date: 8/3/2015 1 JobNo 5124 Subject: Gravity Sewer Extension Application — J Alexander Middle School fail C Messenger Next Day Delivery fl UPS Ground WE ARE SENDING YOU: COPIES DATE 2 8/03/2015 8 Attached DESCRIPTION ast-Track{FTA Ol Under separate cover: Application Check for $480 Flow Acceptance Letter USGS Topo Site Map a 8.5" x Sanitary Sewer Plans and Details THESE ARE TRANSMITTED as checked below: For approval _J Approved as submitted Resubmit copies for approval El For your use 7 Approved as noted ESubmit copies for distribution As requested ( Returned for corrections Return corrected prints For review and comment Remarks: cc: Enclosed are the documents to support the proposed private wastewater system to serve a new middle school. The wastewater system extension will include 548 I.f, of 8 inch diameter PVC pipe and four 48 inch diameter sanitary manholes. The private sanitary sewer will connect to a public sewer manhole within the R.O.W. of Hambright Road in Huntersville. The anticipated flow is 18,000 gallons per day. The sewer will be owned and maintained by the owner, Charlotte Mecklenburg Schools. Please contact me at kwestra@benesch.com or 704.521.9880 if you have any questions. Signature: PS01-0998-06 form Central Files: APS SWP _ 8/17/2015 Permit Number WQ0037950 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRute Permitted Flow 18,000 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name JM Alexander Middle School Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Charlotte -Mecklenburg Schools Dates/Events Owner Type Government - County Owner Affiliation Anthony B. Ansaldo 3301 Stafford Dr Charlotte NC 28208 Orig Issue 8/13/2015 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 8/5/2015 8/17/2015 8/17/2015 Regulated Activities Requested /Received Events School Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin Water Resources Environmental Quality February 28, 2017 . Ms. Peggy Hey, Executive Director of Facility Planning 'and Management Charlotte -Mecklenburg Schools 3301 Stafford Drive Charlotte, NC 28208 SUBJECT: Final Engineering Certification Acknowledgement Project: 3M Alexander Middle School Permit No. WQ0037950 Permittee: Charlotte -Mecklenburg Schools County: Mecklenburg Dear Ms. Hey: ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on February 28, 2017. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http:l/aortal.ncdenr.org/web/wglswp/pslcs/pnoc from the Collection Systems Applications page. Should you have any questions, please do not hesitate to contact me at (704) 235-2143. Sincerely, Barry Love Environmental Specialist cc: Mr. Lester A. Barnes, P.E., (Alfred Benesch & Company, 2320 West Morehead Street, Charlotte, NC 28208) Central Files Nothing Compares:,'t.� State of Nortli Carolina I Environmental Quality' Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue. Suite 301 1 Mooresville, North Carolina 28115 704-663-1699 I FAST TRACK SEWER ENGINEERING CE TIFJCATION PERMITTEE: Charlotte -Mecklenburg Schools PERMIT fi: WQ0037950 PROJECT: JM Alexander Middle School ISSUE DATE: August 13, 2015 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof,. UAL `r . pt'ANtS ptC GCv R. C Aef—tilatavRE.► p 62,272417 Printed Name, Title ►.nature Date ENGINEERS CERTIFICATION J, LEST ,°; I4.i , as a duly r gistered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, weekly, [, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted March 4,1996 as applicable; the Division's Minimum Design Criteria for the fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials.. North Carolina Professional Engineer's Seal w/signature & date: Flnal �1 Partial (include description) Certification Comment, Qualifiers (attach If necessary): NC DWR — Water Quality Regional Operations Section 61.0 East Center Avenue, Suite 30t, Mooresville, NC 2811 Moore vine Regional Office Phone: 170416631699 FAX:17041-6'13,m4n SANITARY SEWER PROFILE 1➢7011,1.2 SA'N11A Y SEWER PLAN & ['ROE4LE 011