HomeMy WebLinkAboutWQ0037723_Regional Office Historical File Pre 2018NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor May 7, 2015 Carl Wilson, P.E. Chief Engineer Charlotte Water 5100 Brookshire Boulevard Charlotte, NC 28216 Subject: Permit No. WQ0037723 Charlotte Water 16408 MacGregor Lane Low Pressure Sewer Sy Wastewater Collection System Extension Perm Mecklenburg County Dear Mr. Wilson: Donald R. van der Vaart Secretary RCCIV NCDFNR'lDW',EI MOoRFSv WORM LE REGIONAL OFFICE In accordance with your application received April 10, 2015, we are forwarding herewith Permit No. WQ0037723, dated May 7, 2015, to Charlotte Water (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference, Please pay particular attention to the following conditions contained within this permit Condition 1.1: The referenced single family residential unit shall be served by an individual simplex grinder pump station with audible and visual alarms, in conformance with the approved plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. Prior to operation, the Permittee or its representative shall inspect and verify that the installation is in accordance with the approved plans and specifications. Condition 1.2: The Permittee shall provide the homeowner with the low pressure sewer customer information package approved by the Department of Environment and Natural Resources. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system perrnit issued to the Permittee. It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement 1617 Mail Service Center, Raleigh, North Carolina 27699--1617 Phone: 919.807-6300\ Enternet: www.ncwaterquality.gr An Equal Opportunity \ Affirmative Action Employer— Made in part by recycled paper Charlotte Water Permit No. VVQo837723 wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC27699-6714. Unless such demands are made, this permit shall befinal and binding. Ifyou need additional information concerning thismatter, please contact Sarah Bass at(919)8O7'63l0 orviam-mai|atSarah.Bao@ncdenr.gov. for IJay Zimmerman, Director Division ofWater Resources, NCDENR byDeborah Gore, Supervisor Pretreatment, Emergency Response, Collection System Unit cc: Sean Mayo, P.E,Gavel 8\Dorn Engineering, PLLC; 673OFreedom Drive, Charlotte, NC 28214 Mooresville Regional Office, Water Quality Section Regional Operations Water Resources Central Files: VVO0U377I3 PERCS(electronic copy) Page 2 of 9 AVA NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Charlotte Water for the construction and operation of approximately 1200 linear feet of 2-inch pressure sewer; as well as one simplex grinder pump with audible and visual high water alarms to serve one single family residence as part of the 16408 MacGregor Lane low pressure sewer system project, and the discharge of 190 gallons per day of collected domestic wastewater into Charlotte Water's existing sewerage system, pursuant to the application received April 10, 2015, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The homeowner along the permitted pressure sewer system will be responsible for installing, owning, and maintaining the simplex pump station connecting to this system. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. forS. Jay Zimmerman, Director Division of Water Resources, NCDENR By Authority of The Environmental Management Commission Permit Number: WQ0037723 Permit Issued: May 7, 2015 Treatment Facility: McAlpine Creek (NC0024970), Irwin Creek (NC0024945), Sugar Creek WWTP (NC0024937) Page 3 of 9 SUPPLEMENT 0�����|T �`y��J��� �X���T .,`~. . ^-^—^..^-.°. ^�� PERMIT v~��v�^x~xox�^_. The Permitt2ei3hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC2T; the Division's Gravity Sewer Minimum Design Criteria adopted February1Z, 1996as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump,Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittce's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. 1. SPECIAL CONDITIONS 1. The referenced single family residential unit shall be served by individual simplex grinder pump station with audible and visual alarms, in conformance with the approved plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. Prior to operation, the Pe/mittee or its representative shall inspect and verify that the installation is in accordance with the approved plans and specifications. 2. The Penmhtee shall provide the homeowner with the |ovu pressure sewer customer information package approved by the Department ofEnvironment and Natural Resources. Page 4 of 9 II. STANDARD CONDITIONS 1. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S. 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein: [15A NCAC 027.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 2T .0108(b)] a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump, stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and Page 5 of 9 the legal means to require grease interceptors atexisting establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer Systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permitteeorits representative. 3. Grease education materials shall be distributed more often than required in Parts(1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. R and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. S. Noncompliance Notification: The Pennittee shall report by telephone to n water resources staff member at the &4onnapviUe Regional Office, telephone number7U4-663'1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, ctc.;or b. Any 5SOand/or spill over 1,OOOgallons; nr c. Any SS[]and/or spill, regardless ofvolume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division nfEmergency Management attelephone number(Q08) 858'0368or(919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part | of Form [S'S30 (or the most current Division approved form) within five days following first knowledge nfthe occurrence. This report must outline the actions taken nrproposed to be taken to ensure that the problem does not recur. Part || of Form [5'55U (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143- 215.lC(al)] 6. Construction ofthe gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tothe surface waters Vfthe State. [15ANCACO2T.0100(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tnthe address provided onthe form. Acomplete certification isone where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary tothe wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permitteetoappropriate enforcement actions. Page 6 of 9 If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T,0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] Page 7 of 9 11.|n the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, 'the Permittee shall take immediate corrective action, including those as may be required hythis Division, such as the construction of additional or replacement 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, orordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required bvthe Division o/any other Federal, State, ofLocal government agencies, [6,S.143-215.1(b)] 13. The Permittee shall provide for the pump station and force main the following items: a. PumnpStation Reliability [15A0[A[OIT.03O5(h)/1)]: 1. Pump stations, except when exempted hvSubparagraph (j)(2) of15A NCAC#2T.03&5, shall bedesigned with multiple pumps such that peak flow can be pumped with the largest pump out ofservice. Z. Astamdbv power Source or pump is required at all purnp stations except for those pump stations subject to Subparagraph (j)/2) of lSA NCAC 02T.0305. Controls shall be provided to automatically activate the standby source and signal an alarm condition. 1 As an alternative to Part (dfo' pump stations with an average daily design f|uvv less than 15,000gaUons per day as calculated using 15A NCA[OZT.0l14, a portable pmm/e/ source or pumping capability may be utilized. it shall he demonstrated to the Division that the portable source is owned or contracted by the permbtee and is compatible with the station, If the portable power source or pomp is dedicated to multiple pomp stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timmeframes, shall be provided in the case of multiple station power outage. 4. As an alternative to Part (|i) for pomp or vacuum stations connecting a single building to an alternative sewer system, wet well storage requirements shall be documented to provide 24'houo' worth ofwastewater storage or, exceed the greatest power outage over the last three yeas or the documented response time to replace a failed pump, whichever is greater. Documentation shall be required pursuant to the permit application, b` All pump stations designed for two pumps o/ more shall have a telemetry system to provide remote notification of problem condition to include power failure and high water alarm. (15A c. High water audio and visual alarm. [16AN[ACO2T.0305(h)(1)(F)] d. Pump stations shall have opermanent weatherproof ^ sign stating the pump station identifier, 24- hour emergency number and instructions to call in case of emergency. Simplex pump or vacuum stations serving a single-family residence shall have placard or sticker placed inside the control panel with a24-hooremergency contact number, [15AN[ACO2T.0305(h)(2)] e. Screened vents for all wet wells. [15AN[ACO2T.0305(h)(3)] The public shall be restricted access to the site and equipment. [15A NCAC 02T.0305(h)(4)] Page 8 of 9 g. Air relief valves shall be provided at all high points along force mains where the vertical distance exceeds ten feet. [15A NCAC 02T .0305(h)(5)] Page 9 of 9 ENGINEERING CERT.11FICATION It Permit PenmhNn: vKC0037723 Project: 1G4o8MacGregor Lane Low Pressure Sev,crSvstem Issue Date: May 7,ZU15 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation, which includes: One copy of the project construction record drawings (plan & profile views of sewer lines & fnnr mains) cfthe wastewater collection system extension. Final record drawings should be clear on the plans vrmn digital media (CD or DVOdisk) and are defined asthe design drawings that are marked uporannotated with after construction information and show required buffers, separation distances, material changes, etc. Permit modifications are required for any changes resulting in non-compliance with this permit. xdetaled description for partial certifications should be attached to this form along with any certification comments. Certification should be submitted in a mariner that clocurnents the Division's receipt. The Permhteebresponsible for tracking all partial certifications UP Until a final certification is received, PERMITTsE'S CERTIFICATION i the undersigned agent for the Peonhteu hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Ponnittee, and the Permittee is prepared to operate 8L maintain the wastewater collection system permitted herein nrportions thereof, Printed Name, Title Signature ENGMeER'S CERTIFICATION 1,__ ______ . , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ([l Periodically, |l weekly, Fl full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: approximately lZWO linear feet of 2-inch pressure sewer; uuwell as one simplex grinder pump with audible and Visual high water alarms to serve one single family residence as part of the 16408 MacGregor Lane low pressure sewer system project, and in conformity with the project plans, specifications, supporting documents, and design criteria subsequently filed and approved. | certify that the construction of the above referenced project was observed to be built within substantial compliance and intent ofthe approved plans and specifications. North Carolina Professional Emginmer'oSe*|w/signature&da/e: [� ��Fina| 0 ��Partia|Un6udedescrption Send the Completed Form & Supporting Documentation iothe Following Address: mCDENn/0WRWATER QUALITY PERMITTING SECTION VVASTEVVATERBRANCM—PERCSVm|r xsz7Mail Service Center Raleigh, NC 27699 ?)1�b��l4:i .o ��ft.,CM t4•.s�c�8{i",:�-$ State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Charlotte Water Project Name for which flow is being requested: 2 Less to serve MacGregor Ln (10 lots) More than one FTSE may be required for a single project if the owner alike WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek WWTP b. WWTP Facility Permit#: MC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 99.0 9.916 69.723 0.0019 79.896 80.7% 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (C)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Studran Steele Creek 2.592 1.037 8.700 3.480 0.013 0.105 0.118 0.918 6.529 0.401 6.930 -3.450 *The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. * A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0, Page 1 of 6 { 1II. Certification Statement: I /(ti A1('7oli • certify to the best of my knowledge that the addition of the vol me oh wastewater to bepermitted in this project has been evaluated alongthe route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections 1 and 11 plus all attached planning assessment addendums for which 1 am the responsible party. Signature his fora indicates acceptance of this wastewater flow. (1) 0)/3,/// Signing 6 `c[al Signature Date Page 2 ot'6 E'I,E.08•l, • FTSE PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 5.8 % and 0.401 MGD of the Available Capacity (E) in Pump Station Steele Creek ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately o. 401 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Steele Creek Pump Station Replacement and Relief Sewer is in design or under construction with planned completion in Summer 2017 ; and/or d. The following applies: The Steele Creek Pump Station replacement project will provide a new regional facility capable of handling build -out flows in the basin. The project has funding appropriated, and will be bid toward the end of 2014 with an expected completion in Summer 2017, Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted without a significant likelihood of over -allocating capacity in I -understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. \' it Ocr�e' Signing Oj-Yi4W 1 Signature Page 3ot6 FFSE0_-13 sl I3 • Gavel & Dorn Engineering, PLLC 6730 Freedom Drive, Charlotte, NC 28214, 704-483-2054 Apri12, 2015 NC DENR/DWR Water Quality Section — Wastewater Branch PERCS Unit 1617 Mail Service Center Raleigh, NC 27699-1636 VIA : US Mail Re: Proposed 2" Low Pressure Sanitary Sewer to serve 16408 MacGregor Lane, Mecklenburg County, NC CW:379-14-537 To whom it may concern, Charlotte Water is requesting approval to extend an existing low pressure sewer system to accommodate one new single family residential unit located off Grand Palisades Parkway near Lake Wylie in the unincorporated part of Mecklenburg County, North Carolina. The extension will consist of approximately 1200 LF of 2-inch pressure sewer along Grand Palisades Parkway, Oleander Drive and through a utility easement that connects to MacGregor Lane. The new pressure sewer will connect to an existing gravity sewer system on Oleander Drive. The existing gravity sewer system located on Oleander Drive drains to the Studman Branch Pump Station that is operated by Charlotte Water, formerly known as Charlotte Mecklenburg Utilities.. This permit shall be for the 16408 MacGregor Lane parcel only. However the flow acceptance form and design calculations have been completed with the assumption that the 10 parcels located at MacGregor Lane will ultimately be connected to the low pressure sewer system. Construction of the new 2-inch Iow pressure sewer will be per CW standard specifications which have been approved for use by NC DENR. CW will not construct the actual wet well and pump but will provide information to the homeowner regarding requirements for its construction. In addition, CW will inspect the wet well and pump installation to ensure its compliance with CW standard specifications prior to allowing connection of the service to the new 2-inch LPSS. Installation of the pump and wet well is the responsibility of the home owner. Maintenance of the pump and wet well will also be the responsibility of the homeowner. Enclosed are the following documents for your review: • (1) check for $480.00 (application fee); • (2) copies sealed construction plans; • (2) Project manuals (one with originals, one with copies) including the following: o Alternative Sewer Extension Application (Form ASEA 10-14; o Flow Tracking Acceptance Form (Form FTSE 08-13); o I lxl7 Site Map; o Engineering calculations; o Customer information brochures; • o Other required information. l t 4/1/15 Page 2 As you are aware, Charlotte Water does not own, install, maintain or operate any individual residential grinder sewage pumping stations. Specifications and detail for the Low Pressure Sanitary Sewer Systems have been approved by the state. Please contact me at 704.724.5047 if you need any additional information or have any questions about the submitted documents. Sincerely, GAVEL & DORN ENGINEERING, PLLC Sean Mayo, P.E.