Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0037585_Regional Office Historical File Pre 2018
CDE R North Carolina department of Environment and Natural Resources Pat McCrory Governor February 10, 2015 Mr. Fred Hazel DD Belgate, LLC 403 Corporate Center Drive, Suite 200 Stockbridge, Georgia 30281 Subject: Permit No. WQ0037585 DD Belgate, LLC Sovereign at Belgate Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. Hazel: Donald R. van der Vaart Secretary In accordance with your application received February 5, 2015, we are forwarding herewith Permit No. WQ0037585 dated February 10, 2015, to DD Belgate, LLC (Perrnittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this per Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Perrnittee. It shall be responsibility of the Permittee to ensure that the as constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1699 \ Fax 704-663-6040 \ Customer Service 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer — Made in part by recycled paper DD Belgate, LLC Permit No. WQ0037585 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. for S. Jay Zimmerman, Acting Director Division of Water Resources, NCDENR by Michael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDENR cc: Eric Hampton, P.E. (electronic copy) Barbara Gross (electronic copy) Tommy Rowland (electronic copy) Regional Office Files Water Resources Central Files PERCS (electronic copy) Page 2 of 8 ATA R-C15ENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the DD Belgate, LLC Mecklenburg County for the construction and operation of approximately 1,120 linear feet of 8-inch gravity sewer to serve 266 apartment units, a 40 person capacity pool, and a 1,194 sq. ft. fitness center as part of the Sovereign at Belgate project, and the discharge of 36,910 gallons per day of collected domestic/commercial wastewater into the Charlotte -Mecklenburg Utility Department existing sewerage -system, pursuant to the application received February 5, 2015, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the st cified conditions and limitations contained therein. for S. Jay Zimmerman, Acting Director Division of Water Resources, NCDENR By Authority of The Environmental Management Commission Permit Number: WQ0037585 Permit Issued: February 10, 2015 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET DD Be]gate, LLC is hereby authorized t©: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte -Mecklenburg Utility Department Mallard Creek. Wastewater Treatment Facility in accordance with Permit Number NC0030210. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable, and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Perrnittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS This permit shall become voidable unless the agreement between DD Belgate, LLC and Charlotte - Mecklenburg Utility Department for the collection and final treatment of wastewater is in full force and effect. [15A NCAC 02T.0304(h)) 2. No flow in excess of the quantity permitted herein, 36,910 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)]. II. STANDARD CONDITIONS This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] Page 4 of 8 I 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)): a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. - b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. Page 5 of 8 5. The Pennittee shall report by telephone to a water resources staff member atthe Mooresville Regional Office, telephone number (7O4) 663'1699, aosoon aspossible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, doe to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, etc.;or b. Any SSOand/or spill over l'OOOgallons; ur c. Any SSOand/or spill, regardless ofvolume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not he considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management attelephone number(80O) 858'0368 or(9l9) 733'3308. Persons reporting any Vf the above occurrences shall file aspill report bycompleting and submitting Part \ of Form CS'SS0 (or the most current Division approved form) within five days following first knowledge ofthe occurrence. This report must outline the actions taken orproposed to be taken to ensure that the problem does not recur. Part 11 of Form [S'SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S.143' 6` Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater, tnthe surface waters nfthe State. [15AN[A[02T.O108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tothe address provided on the form. Acnmp|ete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater 0ovv made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered o violation of the permit and shall subject the Permnitteetoappropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then m copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable Cmunty'm RwQ\otmr of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided asapplicable. Supporting documentation shall include the following: a. One copy ofthe project construction record drawings (plan 0^ profile views of sewer lines 8' force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans oron digital media (CD or QVDdisk\ and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pomp sizing, velocity, pump cycle times, and level control, settings, pump station buoyancy, wet well storage, surge protection, detention time in the vve\ vve||, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If portable power Page 6 of 8 I source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 9ERN0DTEE: PERKH|T#/ PROJECT: ISSUE DATE: FAST TRACK SEWER ENGINEERING CERTIFICATION DD Belgate, LLC VVQ0037585 Sovereign at Belgate February 1CL3Ol5 ° This project shall not beconsidered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior tocompletion of this Certification shall be considered a violation of the permit and shall subject the Perm]1tee to appropriate enforcement actions- The Pernmittee is responsible for tracking all partial certifications op until a final certification is received. 4 Final Certification sh.aK be a complete set ofrecord drawings and design calculations regardless ofwhether partials have been submitted, PERNUT[G^5CERTF|[Ar0m |, the undersigned aQentfmrthePcrnrittee,herebvstatethattNsprojecthesbeencmnstructedpuouarM to the applicable stamdards& requirements, the Professional Engineer below has provided applicable design/construction information tothe PenmitUen, and the Pennktee is prepared to operate & maintain the wastewater collection system permitted herein orportions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION L , as a clyly registered Professional E rinthe State ofNorth CaroHna, having been authorized to observe ( periodically, [ | xveekky LJ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the bestof my abilities, due cane and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; IGA N[ACO2T; the Division,mfVVoter Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable,- the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: F� Final Partial (include description) Certification Comments/Qualifiers (attachifnmmmssa"): mCoVVR—Water Quality Regional Operations Section 61OEast Center Avenue, Suite 30I'Mooresville, NC20l1J USE THE TAB KEY TO MOVE FROM FIELD TO FIELD OwnerlPermittee: Apptication Num (to be completed by DD BELGATE LLC, A GEORGIA LIMITED LIABILITY COMPANY Full Legal Name (company, municipality, HOA, utility, etc.) lb. FRED HAZEL Signing Official Name and Title (Please review 15A NCAC 2T .t1106 (b) for authorized signing officials) 1 c. The legal entity who will own this system is: 0 individual ❑ Federal ❑ Municipality 0 State/County ❑ Private Partnership Corporation ❑ Other (specify): O Id. 403 CORPORATE CENTER DR, SUITE 200 11 Mailing Address GEORGIA Z State • 1 h_ 770-474-4345 1 i. 770 474-5213 Telephone Facsimile 2 Project {'Facility) Information:. 2a. SOVEREIGN AT BELGATE _ Brief Project Name (permit will refer to this name 3. Contact Person: 3a. ERIC HAMPTON, P.E Name and Affiliation of Someone 3b. 704-409-1 B05_ Phone Number Project is New ❑ Modification (of an existing permit) Owner' is ❑ Public (skip to Item 8(3)) le. STOCKBRIDGE City lg. 3028 Zip Code FRED@DAVIDVGA.CO E-mail 2b. MECKLENBURG County Where Project is Located placation AMPTON�I-IIMLEY-HORN.COM 3c. ER6C H E-mail dification, Permit No.: Private (go to Item 2(a)) 2a. if private, applicant will bee ❑ Retaining Ownership (i.e. store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to Item B(3)) El Selling units (lots, townhomes, etc. - go to Item B(2b)) CHARLOTTE MECKLENBURG UTILITY DEPARTMENT 2b. If sold, facilil es owned by a (must choose one) ❑ Public Utility (Instruction D) ❑ Homeowner Assoc /Developer (Instruction E) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, MALLARD CREEK. Name of WWTF 5a. CMUD Owner of Downstream Sewe Z 6. The origin of this wastewater 5b. 10 Gravity 5c Receiving Sewer Size ❑ Force Main (check all that apply): ❑ Residential Subdivision Apartments/Condominiums 0 Mobile Home Park ❑ School • Restaurant ❑ Office 4b. NC0030210 WWTF Permit No. #410556„om 12-12) Permit # of Downstream Sewer ❑ Retail (Stores, shopping centers) ❑ Institution ❑ Hospital ❑ Church 0 Nursing Home Other (specify):_ 7. Volume of wastewater to be allocated or permitted for this particular project: 36,910 *Do not include future flows or previously permitted allocations the permitted flow is zero, indicate why: ❑ Pump Station, Outlet, or Interceptor Line where flow will be permitted in subsequent pe • Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) nstruction F 100% Domestic/Commercial Industrial (Attach Description) % Other th (Attach Description) gallons per day nnr o this line FTA 10-14 APPLICATION Paec 4 of 6 0 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 266 apartment units x 135 gpd/unit 35,910 gpd 40 person capacity pool x 10 gpd/person = 400 gpd 1,194 sqft fitness center x 50 gpd/1o0sgft = 597 gpd 35, 910 + 400 gpd + 597 gpd = 36,910 gallons per day *values obtained from Water and Sewer Flow Acceptance Letter 10 Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 1120 New Gravity or Additional Force Main NEW GRAVITY 11, Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump 'Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Design Flow (MGD) Latitude: Operational Point Power Reliability Option GPM @TDH 1 - permanent generator wlATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Location ID: (self chosen - as shown an planslmap for reference) Longitude: Latitude: Design Flow Operatlonal Point Power Reltability Option (MGD) GPM TDH 1 - permanent generator w1ATS; Force Main Size Force Main Length 2 - portable ,generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment fa Yes No If Yes, permit number of 2°" treatment facility (RO — if )(es" to 6,12 please contact the Central Office PERCS Unit) Does the sewer system comply with the Minimum Design Criteria for the PePum Stations nd Pone fain (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and ED Yes LJ No If No, complete and submit the Variance/Alternative Design Request (VAPC 1O-°14) application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. ETA 10-14 APPLtCa\TIOT Page 5 of 6 14. Have the foliowing permits/certifioations been submitted for approval for the system or p Wetland/Stream Crossings - General Permit or 401Certification? Sedimentation and Erosion Control Plan? Trout Buffer Waiver? Stomnwater? [] Yes ©No ® Yes 11 No d Yes ©No ®Yes ©No ect to be served? N/A © N/A N/A ID N/A 15. Does this project include any high priority lines (15A NCAC P2T ,0402 (21) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and roust be checked once every six mnths Check if Yes: © and provide details: Owner/Permittee's Certific nature of Signing Official and Project Name) 1 A-7.p. j. - attest that this application for SOVEREIGN AT BE GATE has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any applrca fN�rall be ,guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penaltiie p tr, $25,000 per violation. Signing Official Signatu Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY +tJ) TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 z 0 2.. Professional Engineers Certification: (Signature of Design Engineer and Project Name) 1, ERIC HAMPTON, P,E, ;attest that this application for , SOVEREIGN AT BELGATE has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-2.15,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may. include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. ERIC HAMPTON, P.E. Professional Engineer Name 2b. KIMLEY-HORN AND ASSOCIATE, INC. Engineering Firm 2c, 2000 SOUTH BLVD, SUITE 440 Mailing Address 2d. CHARLOTTE City 2g, 704-409-1805 2h, Telephone Facsimile 2e. NC 2f. 28203 State Zip 2i. ERIC,HAMPTON@KIMLEY- HORN.COM q `f A IO.'14 A PLACATION Page 6 of 6 CIRKLOTTF CHARLOTTE-MECKLENBURG UTILITY DEPARTMENT November 5, 2014 Ms. Layton Bodkins Kimley-Horn & Associates, Inc. 2000 South By. Suite 440 Charlotte, NC 28203 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE SOVEREIGN AT BELGATE TAX PARCEL# 047-461-01,-08 C-MUD TRACKING# 600-14-653 A flow acceptance study of the subject site has been completed and the following has been determined: Charlotte -Mecklenburg Utility Department (C-MUD) agrees to accept the additional gravity sewage flow of 36,910 gallons per day (266 apartment units x 135 gpdiunit, 40 person capacity pool x lOgpd/person; 1,194 ft2 fitness center x 50 gpd/100 ft') from this project for transmission to the Mallard Creek Wastewater Treatment Plant; NPDES permit number NC0030210, for treatment, This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached FTSE form. C-MUD agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDENR. However, C-MUD cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MUD system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acceptance study, and payment for any service connection(s) has not been received within (1) year of issuance of this flow acceptance letter, this approval shall be rescinded and a new flow acceptance study must be made, If you have any questions, you may contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant CHARLOTTE-MECKLENBURG UTILITY DEPARTMENT Engineering Division • bnstallation & Development Services www,cmutilities.com 700 North Tryon Street Charlotte, NC 28202 Ph: 704/432-5801 Fax: 704/432-5804 CHARWTTL CHARLOTTE-MECKLENBURG UTILITY DEPARTMENT November 5, 2014 Ms. Layton Bodkins Kimley-Horn & Associates, Inc. 2000 South Bv, Suite 440 Charlotte, NC 28203 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE SOVEREIGN AT BELGATE TAX PARCEL# 047-461-01,-08 C-MUD TRACKING# 600-14-653 A flow acceptance study of the subject site has been completed and the following has been determined: Charlotte -Mecklenburg Utility Department (C-MUD) agrees to accept the additional gravity sewage flow of 36,910 gallons per day (266 apartment units x 135 god/unit, 40 person capacity pool x 10gpd/person; 1,194 ft' fitness center x 50 gpd/100 ft') from this project for transmission to the Mallard Creek Wastewater Treatment Plant; NPDES permit number NC0030210, for treatment This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached FTSE form. C-MUD agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDENR. However, C-MUD cannot guarantee a constant pressure or quality of flow, Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MUD system is accerited on a first come first served basis, The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction, If the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acceptance stud and a ment for an service connection s has not been received within (1) year of issuance of this flow acceptance letter, this approval shall be rescinded and a new flow acceptance study must be made If you have any questions, you may contact me at (704) 432-5801. Sincerely. Barbara Gross Engineering Assistant CHARLOTTE-MECKLENBURG UTILITY DEPARTMENT Engineering Division • Installation & Development Services www,cmutilities,com 700 North Tryon Street Charlotte, NC 28202 Ph: 704/432-5801 Fax: 704/432-5804 State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: .itn- -Ho—n & kssociateS Project Name for which flow is being requested: Sovereign at Belgate tiore than one ETV may be required,for a single project if the owner of the WWTP is not responsible fi)r all stations along the route of the proposed 'astvaterflow . Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Mallard Creek WWTP b. WWTP Facility Permit #: Nc003021,D c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg.. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used Alt are in MGD 12.00 0.749 8 538 Q . 036.91 9.324 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flo W . List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=--(A-D), Design Obligated, Puuip Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MCI) MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump s a factor (pf not less than 2.5.. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. divided by a peaking Page 1 of 6 1:1-S1-. 08-13 III. Certification Statement: I e.,( bI `1..n certify to the best of my knowledge that the addition of l the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all atta hed planning assessment addendums for which I am the responsible party. Signatalre qis form indicates -acceptance of this wastewater flow. Sign rrcial Signature Page 2 of 6 he3P1 FTSE 08-.13 Ki ey>» Horn D N XC SOVEREIGN AT BELGATE I.EA BOULEVARD CHARLOTTE, NC USGS TOPOGRAPHIC MAP FIGURE 1 Corporations Division Page 1 of 1 4,G,y°," ° North Carolina 1 4- ; . � Elaine F Marshal L)E ARTM ENT OF THE :t_i_ Secietaiy 'E CRETARY OF Si P . i, et° PO Sox. 2! a3 Raleigh, NC 27626%0622 (919 Ei77-2000 Account ` Login Many state agencies, including the Secretary of State's Office, are currently experiencing Register telephone issues, especially in regards to voice mail messages being left and retrieved. If you are trying to reach us by phone and you are not allowed to leave a voice mail, we urge you to keep calling until you have reached the staff member or specific office you are trying to contact. Click Here To: View Document Filings File an Annual Report Print a Pre -Populated Annual Report form Amend a Previous Annual Report Corporate Names Legal: DO Belgate, LLC Limited Liability Company Information Sosld: Status: Annual Report Status: Citizenship: Date Formed: Fiscal Month: State of Incorporation: Registered Agent: Corporate Addresses 1385010 Current -Active Current Foreign 6/16/2014 December GA CT Corporation System Reg Office: Reg Mailing: Mailing: Principal Office: 150 Fayetteville St., Box 1011 Raleigh, NC 27601-2957 150 Fayetteville St., Box 1011 Raleigh, NC 27601-2957 403 Corporate Center Drive Suite 201 Stockbridge, GA 30281-9023 403 Corporate Center Drive Suite 201 Stockbridge, GA 30281-9023 Company Officials General Manager: Morrow Investors, Inc. 403 Corporate Center Drive, Suite 201 Stockbridge GA 30281 http://www.secretary.state.nc.us/Search/profeorp/10549543 2/6/2015 ��~8�� `��8�Q��0~�� �`�Un p mU�~� '�" Horn � U v NCDENR:Mooresville Regional Office Sanitary Sewer Permitting 61OE.Center Ave. MounsaviUo. North Carolina 28115 RE: Sovereign at Belgate Fast Track Application for Gravity Sewers Tnwhom itmay concern, The proposed multifamily development project will consist of constructing 182 units located north of Ikea Boulevard and 84 units located south of Ikea Boulevard (266 total unit development), The project will also include the relocation and abandonment of an existing CMUD 8" and 10" sanitary Sewer system. The 182 units north of Ikea Boulevard sanitary sewer system will tie into the existing 10" sewer main located along the, northwest edge of the property which is located in a Charlotte Mecklenburg Utilities Department 15 public sanitary sewer easement, The 84 units south of Ikea Boulevard wiil tie into the existing 8" sanitary eavver system and the relocated 8^ sanitary sewer maim that is located in the southern portion of the property that will be in a Charlotte Mecklenburg Utilities Department 40' public sanitary sewer easement. Please contact mmot704.400,1816orketie,qeshould you need any additional Sincerely' KaUUin /3ek*c E.I.T. kimley-horn.com �� Transmittal Date: 01/30/15 Job Number; 018478001 Project Name: Sovereign at Be!gate To NCDENR: Mooreseville Regional Office Sanitary Sewer Per 610 E, Center Ave, Mooresville, NC 28115 We are sending these by U.S. Mail r— Other: FedEx Suite 440 2000 South Boulevard Charlotte, North Caro5na 28203 TEL 704 333.5131 Hand Deliver We are sending you Attached Under separate cover via Shop Drawings Prints/Plans I Samples Other the folio \itiiing Item& Specifications 1 Change Orders Copies Date No, Description Cover leiter 0E30'15 01 /30115 01/30/15 01 /30115 01130/15 01/130115 Fast 1 Application (FTA 10-14) Check - Fast Track Application Permitting Fee Letter rrom. \il Floss Tracking/Acceptance Form (FTSE 08-13) USGSI Topographic Map oh Project Site These are transmitted as checked below, L Remarks: Please find enclosed package for NCDENR Fast Track Sewer Permitting, Thanks, Copy to: 11 Approved as Sehrnitted E Approved as noted Resubmit Submit For your use Ei As requested For review and comment Returned for corrections Return Signed Katlin Geier, ET 5:b016P 15r000peoiii4.1 • • • • • Copies"..for disttibuberp Corrected prints Central Files: APS SWP _ 2/10/2015 Permit Number WQ0037585 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 36,910 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Sovereign at Belgate Location Address Owner MajorlMinor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Dd Belgate LLC A Georgia Limited Liability Co Dates/Events Owner Type Non-Govemment Owner Affiliation Fred Hazel 403 Corporate Center Or Stockbridge GA 30281 Orig Issue 2/10/2015 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 2/5/2015 2/10/2015 2/10/2015 Regulated Activities Requested !Received Events Apartment complex Condominium Wastewater collection Outfall Additional information requested Additional information received Waterbody Name StreamIndex Number Current Class Subbasin