Loading...
HomeMy WebLinkAboutWQ0021302_Application (FTSE)_20211118Permit Number WQ0021302 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean. hunkele Coastal SWRule Permitted Flow 272,000 Facility Name Waterford of the Carolinas Sewer Location Address Owner Owner Name Town of Leland Dates/Events Central Files: APS _ SWP _ 8/1012021 Permit Tracking Slip Status Project Type In review Major modification Version Permit Classification I Individual Permit Contact Affiliation MajorlMinor Region Minor Wilmington County Brunswick Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation David A. Hollis 102 Town Hall Dr Leland NC 28451 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective sn/2ooz 8/5/2021 �=3 il `� ;q 4--� CAPE FEAR ENGINEERING 151 Poole Rd., Suite 100, BeMlle, NC, 28451 TEL (910) 38X 1044; FAX (910) 383-1045 X ..caperearengineedng.c To: NCDEQ-Division of Water Resources Wilmington Regional Office 127 Cardinal Drive Wilmington, NC 28405 Attn: Dean Hunkele F G E iV Is--- AUG 0 5 2021 Transmittal Date: August 5, 2021 File: 650-43 "34" � subject: Waterford Commercial (Lot 14R) Sewer Permit W00021302 ❑ As Requested ❑ For Your Files ❑ For Distribution ® For your Review / Action / Approval ❑ Sent via Mail ❑ Sent via Courier Quantity Drawing No. Description 1 Original Application Fee $480.00 2 Copies Data Compact Disk 1 Copy Cover Letter 2 Original & Copy Fast Track Sewer Extension Application Form (FTA 06-21) 1 Copy USGS Location Map 1 Copy Sewer Project Narrative 1 Copy Technical Specifications 2 Copies Construction Plans (2 Full) REMARKS Please find the enclosed documents for your review. If you have any questions or require additional information, please contact our office. Thank you. CC: I Cape Fear Engineering r File 650-43 "34" RECE1VED/NCDENR4)WR Signed: Shannan Lowe, 1 AUG 0 5 2021 Received By: Water Ouality Re OPeretbns secum Date: WXmirom psgww om'e Project Narrative For Sewer Permit Modification Subject: Waterford Commercial (Lot 14R) WQ0021302 Brunswick County, North Carolina Date: August 2021 Prepared by: CAPE FEAR ENGINEERING, INC 151 Poole Road, Suite 100 Belville, NC 28451 (910)383-1044 N.C. LICENSE NO. C-1621 CAPE FEAR ENGINEERING August 5'h, 2021 Dean Hunkele Senior Environmental Specialist NCDEQ-Wilmington Regional Office 127 Cardinal Drive Wilmington, NC 28405 Subject: Sewer Permit Modification for Waterford of the Carolinas (WQ0021302) Dear Dean: On behalf of the CIGG, LLC and H2GO, Cape Fear Engineering, Inc. is requesting to modify the existing Waterford sewer permit (WQ0021302) to re -allocate sewer flows and to permit an extension to the existing gravity system to allow for the collection of sewer from Waterford Commercial Lot 14R. This modification intends to reallocate flow within the Waterford Development and use flow that has been allocated to current and future commercial development projects within the Waterford Commercial North section of the development. Please note that the proposed re -allocation makes no change to the previously approved 272,000 GPD. The anticipated daily flow from the facility will be 2,500 GPD, and Lot 14R has 10,591 GPD allocated. The known flow will be revised for the Waterford Commercial North and the balance (8, 091 GPD) will remain in future for Lot 14R. This re -allocation does not change the previously permitted flow allocations for Waterford Commercial North, nor the overall Waterford of the Carolinas project. Therefore, no additional flow is being requested in regards to development of the project on Lot 14R. As such, no revisions are required to Flow Tracking Acceptance forms. I trust that this information is sufficient for your approval of this request. If you have any questions or need any additional information, please contact me directly. Sincerely, Kyle erring, P.E. cc.. He 650-43 "34" PeiO43 Loy HR Wvx[[o[d' dJ) MIN SEWER8621-ON-03 J., __ ,... 333 3 .. 7 J( 3 J 3 3 3 3_.- 3 GENERAL: On behalf of the CIGG, LLC and H2GO, Cape Fear Engineering, tnc. is requesting to modify the existing Waterford sewer permit (WQ0021302) to re -allocate sewer flows and to permit an extension to the existing gravity system to allow for the collection of sewer from Waterford Commercial Lot 14R. This modification intends to reallocate flow within the Waterford Development and use flow that has been allocated to current and future commercial development projects within the Waterford Commercial North section of the development. WASTEWATER PROJECTION: Please note that the proposed re -allocation makes no change to the previously approved 272,000 GPD. The anticipated daily flow from the facility will be 2,500 GPD, and Lot 14R has 10,591 GPD allocated. The known flow will be revised for the Waterford Commercial North and the balance (8, 091 GPD) will remain in future for Lot 14R (see attached). SYSTEM DESIGN: Gravity System: The gravity sewer system for the project has been sized in accordance with the requirements set forth in "NCDENR Minimum Design Criteria for the permitting of Gravity Sewers". TREATMENT FACILITY: The current modification is a reallocation on flow, and no new flow is being requested. Waterford Commercial North has been approved for the Northeast Brunswick Regional WWTF. When additional flow capacity is required for future phases it will be requested. OPERATION AND MAINTENANCE: H2GO will be responsible for the operation and maintenance of the sanitary sewer system. Waterford Commercial North Flow Breakdown Lot # Type of Use Lot Size (Ac) (Acres) Known Flow (GPD) Future Flow (GPD) Fut. Flow (GPD/Ac) Total Flow (GPD) Lot 7 Unknown Future Development 8.33 0 14,6071 1,754 14,607 lot 8 Existing Corning Credit Union 1.18 375 0 0 375 Lot 9 Proposed Car Wash 2.05 3200 0 0 3,200 Lot 10 Existing Goodwill 2.15 867 0 0 867 Lot 11 Unknown Future Development 1.50 0 2,630 1,754 2,630 Lot 12 Unknown Future Development 18.17 0 31,862 1,754 31,862 Lot 13 Unknown Future Development 2.00 0 3,507 1,754 3,507 Lot 14R Unknown Future Development 6.04 2,500 8,091 1,754 10,591 1 4442 1 63,1981 67,640 Note that the above does not include portion of Waterford Commercial Development permitted October 5, 2007 which included the Harris Teeter Center and Lots 1-5 DWR Division of Water Resources Application Number: State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: H2GO (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: per 15A NCAC 02T .0106(b) Title: 4. Applicant's mailing address: P.O. Box 2230 City: Leland State: NC Zip: 28451 5. Applicant's contact information: Phone number: (910) 371-2456 Email Address: bwalker@h2goonline.com ❑ Privately -Owned Public Utility ❑ Other 11. PROJECT INFORMATION: 1. Project name: Waterford Commercial (Lot 14R) 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project `o If a modification, provide the existing permit number: WQ00 and issued date: For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: W00021302 3. County where project is located: Brunswick 4. Approximate Coordinates (Decimal Degrees): Latitude: 34 13' 17.29" N Longitude: 78'I'5.88" W 5. Parcel ID (if applicable): 0370005560 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Kyle Herring License Number: 048839 Firm: Cape Fear Engineering Mailing address: 151 Poole Road. Suite 100 City: Belville State: NC Zip: 28451- Phone number: (910) 383-1044 Email Address: kyle,herring(a)capefearenyineering.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Northeast Brunswick Wastewater Treatment Facility Permit Number: NCO086819 Owner Name: Brunswick Countv V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ0018076 2. Downstream (Receiving) Sewer Information: 8 inch Z Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): H2Go FORM: FTA 06-21 Page I of 5 VI. GENERAL REQUIREMENTS L If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ® No ❑ N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ® No ❑ N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by I5A NCAC 02T.0I 15(c) been attached? ❑ Yes ® No ❑ N/A 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming PooUFilter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : % Domestic 100 % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(t)) Daily Design Flow '•" No. of Units Flow Business/Office 25 gal/emp. 100 2.500 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 2,500 GPD a See 15A NCAC 02T .0114(b), (d). (e)(l) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: _GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ® Flow has already been allocated in Permit Number: WO0021302 Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: ETA 06-21 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 395 SDR-35 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Total number of pumps at the pump station: _ 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C. Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): Required for all pump stations with an average daily flow greater than or equal to I5,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than I5,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f) & (g)? ❑ Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application * 15A NCAC 02T.0305(s) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee 2. Does this project comply with the minimum separation requirements for water mains? M Yes ❑ No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/seated by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? M Yes ❑ No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: M No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes M No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? M Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes M No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters. siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest versionl and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit and oroiects requiring a variance approval may be subject to longer review times. For oroiects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the proiect, the full technical review is required. 2. Professional Engineer's Certification: I, VG4je WwrpibAG attest that this application for komolyy COIMN1l�ZC,tl1 r L,_ \ (Professional Engineer's name fr Appliem�atiion Item lll.l.) (Project Name from Applicmion Item ILl) I'-_J has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitter of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, 0 b WG I U- , attest that this application for /Z/ R (Signature Authority Name From Application Item 1.3.) (Project Name from Application Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief. and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Z4 Date: T Z.?- -�-) FORM: ETA 06-21 Page 5 of 5 CAPE FEAR ENGINEERING 151 Poole Rd., Suite 100, BeMle, NC, 28451 TEL (910) 383.1044; FAX (910) 383-1045 www. cepefearengineering. c To NCDEQ 127 Cardinal Drive Ext. Wilmington, NC 28405 Attn: Dean Hunkele Transmittal 2021 650-43"35" SEP 2 4 2021 Waterford Commercial (Lot 14R) Sewer Modification Request WQ0021302 Additional Info ❑ As Requested ❑ For Your Files ❑ For Distribution ® For your Review / Action / Approval Quantity Drawing No. Description 1 Copy Response Letter 1 Copy Plat Maps (43/84, 108/47) 1 Copy Lot Exhibit, Lots 1-5 (for General Reference Only) 1 Copy Revised Flow Tracking Breakdown CC: File 650-43 "35" RECEIVED/NCDENFii 't1"'1 SEP 2420?1 Water Quw ty Reglanel wt.WSWIM w pegww o"l -'O Cape F r Engin ng, Inc. Signed: yle erring, P Received By: Date: September 22, 2021 Dean Hunkele NCDEQ Environmental 127 Cardinal Drive Ext. Wilmington, NC 28405 CAPE FEAR ENGINEERING Program Consultant Subject: Request for Additional Information #1 Sewer Modification Request (WO0021302) Waterford Commercial (Lot 14R) Brunswick County, NC Mr. Hunkele, Please find below Cape Fear Engineering's responses to comments provided for the above referenced permit submittal. Can you provide a breakdown on flow usage for the Commercial Outparcel Lots 1-5 that were provided allocation of 6,600 gpd using 880 gpd/ac on 10-5-2007? 1 need to see if more flow needs to be utilized from the existing 51+K balance to cover them. Also, the one you provided hasn't been updated to show the car wash on Lot 9 along with the apartments on Lot 12 are existing. Response: We have requested the flow data from H2Go for Lots 1-5. See attached revised flow tracking sheet with updated Lots 9 and 12. 2. Also, do you have a current map/layout of all the outparcel lots numbered? Not sure where Lot 6 is supposed to be located either. Response: See attached Plat Maps with Parcel Numbers (PM 43184, PM 108147) 3. Lastly, is the proposed office building on Lot 14R using all the acreage as it appears not? Wanted to make sure I understand the summary you provided. Response: You are correct, there will be future improvements on Lot 14R and at that time future flows will be reallocated within the Lot Total. The current facility has an anticipated flow of 2,500 GPD (25 gal/employee/shift per 15A NCAC 02T .0114 with an anticipated 100 employees). I trust the information provided is sufficient for your approval and execution of the permit application. If you have any questions, concerns, or need any additional information, please contact our office. Sincerely, Cape Fear Engineering, Inc. 151 Poole Road, Suite 100 • 6eloille, NC 28451 • TEL: (910)383.1044 • FAX (910)383-1045 www.copefearengineering.com 1 Waterford Commercial North Flow Breakdown Lot # Type of Use Lot Size (AC) Known Flow (GPD) Future Flows (GPD) Approx. Future Flow/AC (GPD) Total Flow (GPD) Lot #7 Unknown Future Development 8.33 0 14,607 1,754 14,607 Lot #8 Existing Cornign Credit Union 1.18 375 0 0 375 Lot #9 Exisitng Car Wash 2.05 3,200 0 0 3,200 Lot #10 Existing Goodwill 2.15 867 0 0 867 Lot #11 I Unknown Future Development 1.5 0 2,630 1,753 2,630 Lot#12 Leland Station (Multi -Family) 18.17 17,400 14,462 1,754 31,862 Lot #13 Unknown Future Development 2 0 3,507 1,754 3,507 Lot#14R Medical Office (& Unknown Future) 6.04 2,500 8,091 1,753 10,591 (TOTALS: 1 24,342 1 43,297 1 1 67,639 Note that the above does not include portion of Waterford Commercial Development permitted October 5, 2007 which included the Harris Teeter Center (Lot 6) and Lots 1-5. x: ,y "Ca, Via7 L'e and ttis Care _ at Cllr „ r 8 7 �Jprr e dive G, _ - Qr :i a � _ .°' =•r� a rout C. % �: d $� ('late o ay .:Poole Rdwr* Panera Bfeady Caplear ;' Y 4 \ food Company Port rlt, J�va` -� Ta!'.eOJ • �. ° x o '. � nkeuDel i e � y " I f • "o.'.TW1? .. r :.Poole d f pc :ear ; /77 Ee"T r City ' 2SE Jayy, S � r'YY C' Hunkele, Dean From: Kyle Herring <kyle.herring@capefearengineering.com> Sent: Thursday, November 11, 2021 9:09 AM To: Hunkele, Dean Cc: Scott Lewis; Matt Haley Subject: RE: [External] RE: ADD INFO WQ0021302 Waterford Commercial modification request and flow allocations Attachments: Waterford Overall Exhibit - R1.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hi Dean, See responses to comments below as well as a revised exhibit. Let us know if you have any additional questions. Thanks, Kyle Herring, PE CAPE FEAR ENGINEERING kyle. herring Acapefearena ineerina.com PH: 910.383.1044 Ext. 110 1 C: 910,386.3731 151 Poole Road, Ste.100 [ Belville, NC [ 28451 Notice: The information contained in this message is intended only for use of the individual(s) named above and may contain confidential, proprietary or legally privileged information. No confidentiality or privilege is waived or lost by any mistransmission. If you are not the intended recipient of this message you are hereby notified that you must not use, disseminate, copy it in any form or take any action in reliance of it. If you have received this message in error please delete it and any copies of it and notify the sender immediately. From: Hunkele, Dean <dean.hunkele@ncdenr.gov> Sent: Tuesday, November 9, 2021 12:08 PM To: Kyle Herring <kyle.herring@capefearengineering.com> Cc: Scott Lewis <slewis@h2goonline.com>; Matt Haley <matt.haley@capefearengineering.com> Subject: RE: [External] RE: ADD INFO WQ0021302 Waterford Commercial modification request and flow allocations Importance: High Thanks Kyle. So it looks like we have Outparcels 1-5 being short on allocation by about 2000 gpd and under on the Lot 6 uses by about 4000 gpd, thus overall we are still good and think we should leave the system descriptions alone on them and not worry about updating them or the flow any longer. - Agree, we are good with this. How certain is everyone with the future identified uses on Lots 7A and 15R? Do you want that allocation specified now or later? If more line will be needed for either or both, then probably best not to allocate those needing line now. We are very confident in those flows provided and both of those facilities are under construction. We did the design for 15A and the Town confirmed the proposed # of rooms for the 7A Hotel site. On the rest of the unknown areas do you want the volumes assigned by Lot now or just leave the new positive balance intact to be used as development becomes known? By the way, how was the per acre rate you listed arrived at? - We were planning to allocate now based on the remaining acreages. I have added some information to the exhibit but we allocated based the remaining acreages and remaining flow. So we allocated 33,953 GPD across the 13.58 future acres to get our 2,500 GPD/Ac allocation. Dean Hunkele (Dean. Hunkele@ncdenr.¢ov) Environmental Program Consultant Water Quality Regional Operations Section Division of Water Resources/Department of Environmental Quality DWR Website: http://www.ncwater.org Wilmington Regional Office 127 Cardinal Drive Ext Wilmington, NC 28405 910.796.7215 Reception Desk 910.796.7380 Direct 910.620.1685 Field/Telework Mobile Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties ALERT: New Fast Track application is available; older version will not be accepted after September 2021 The goal of the Fast Track sewer permit program is to issue a permit in no more than 30 business days from application receipt. Please use the DEQ's Permit Application Tracker to determine the official application receipt date to allow you to estimate a date for issuance and find the reviewer's name. Once issued, the record stays on the site for 30 days. For previously issued sewer permit info or to check on sewer certification receipt status, please use the DWR's Sewer Extension Permit Tracker. Confirmation using this method will replace letters and emails; it is recommended that confirmation be printed and/or saved Links to both trackers can be found on the sewer permitting site here: https://deg.nc.goy/about/divisions/water-resources/water-resources- perm its/pe res/col lectio n-syste ms-perm its From: Kyle Herring [mailto:kvle.herrinR capefearengineerina com] Sent: Friday, November 5, 2021 1:25 PM To: Hunkele, Dean <dean.hunkele@ncdenr.aov> Cc: Scott Lewis <slewis(a@h2aoonline.com>; Matt Haley <matt.halev@capefearenRineering.com> Subject: RE: [External] RE: ADD INFO WQ0021302 Waterford Commercial modification request and flow allocations CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Good Afternoon Dean, See attached Overall Waterford Commercial breakdown and exhibit for review and please let me know if have any questions or comments. Thanks and have a great weekend, 100' 0 100' 200' / 1 INCH = 100' / CO NW tiW / 0 V O LOT c� 1 \� 6,16 LOT #7 B LOT L \ #2 \, \\ \\\\ LOT �/ , ;� % — Olde Regent Way Lq JL - IN,\ �y \�\ \ \ LOT LOT #8 LOT #9R \ oar Lot # Owner NCAC 2T Use 2T Design Units GPD/Unit/Day # Units Total Flow Lot#1 Wells Fargo Bank Employee/Shift 25 7 175 Lot #2 Smithfield's Chicken and BBQ Restaurant, Single ServiceSeat Articles 20 100 2,000 Lot#3 Multi -Use (See Below) (3-1) Panera Bread Restaurant, Single Service Articles Seat 20 100 2,000 (3-2) Pivot Physical Therapy Medical, Medical Office Practioner/Shift 250 3 750 (3-3) Capelli Salon Beauty Shop Booth 10 125 1,250 (3-4) Your CBD Store Stores, No Food Service Every 1,000 SF 100 1.675 168 Lot #3 Total 4,168 Lot#4 Multi -Use (See Below) (4-1) Five Guys Restaurant, Single Service Articles Seat 20 50 1,000 (4-2) VACANT (AS OF 11/5/21) Stores, No Food Service Every 1,000 SF 100 1.675 168 (4-3) Club Pilates Fitness, Exercise Every 100 SF 50 16.75 838 (4-4) Intracoastal Reality Corporation Office Facility Employee/Shift 25 1 10 250 Lot #4 Total 2,255 Lot #5 Harris Teeter Fuel Station Employee/Shift 25 2 50 Lot #6 Multi -Use (See Below) (6-1) Islands Fresh Mex Grill Restaurant, Single Service Articles Seat 20 100 2,000 (6-2) Ultratan Beauty Shop Booth or Bowl 125 4 500 (6-3) Papa Johns Restaurant, Single Service Articles Seat 20 20 400 (6-4) The UPS Store Stores, No Food Service Every 1000 SF 100 1.4 140 (6-5) Mattress Emporium Stores, No Food Service Every 1000 SF 100 1.4 140 (6-6) Greatest Potential Chiropractic Medical, Medical Office Practitioner/Shift 250 2 500 (6-7) Splish Splash Dog Wash Beauty Shop * Booth or Bowl 125 4 500 (6-8) Wok & Roll Restaurant, Single Service Articles Seat 20 20 400 (6-9) Christophers Steak House Restaurant, Full Service Seat 40 100 4,000 (6-10) Computer Warriors Stores, No Food Service Every 1000 SF 100 1.4 140 (6-11) Falcone's Italian Restaurant Restaurant, Full Service Seat 40 50 2,000 (6-12) Beverly Nails Beauty Shop Booth or Bowl 125 4 500 (6-13) Great Clips Barber Shop Chair 50 8 400 (6-14) Luxe Home Interiors Stores, No Food Service Every 1000 SF 100 4.2 420 (6-15) Harris Teeter Shopping Center, w/ Food Service Every 1000 SF 130 48 6,240 (6-16) Jersey Mike's Restaurant, Single Service Articles Seat 20 20 400 (6-17) Alayna's Boutique Stores, No Food Service Every 1000 SF 100 1.675 168 (6-18) Hallmark Stores, No Food Service Every 1000 SF 100 1 1.675 168 (6-19) Dental Works Medical, Medical Office Practitioner/Shift 250 4 1,000 Lot #6 Total 20,015 A II OT I E 17 II II Lot#7A Hotel Hotel w/o In -Room Room 120 110 13,200 Lot#7B FUTURE/UNDEVELOPED Future Use GPD/ACRE 2338 4.92 11503 Lot #8 Corning Credit Union Bank Employee/Shift (+50 GPD for Public Restroom) 25 7 225 Lot #9R Shores Express Car Wash Car Wash Facility Based on Similar Faculties 3200 1 3,200 Lot #10R Goodwill Industries of Eastern NC, Inc. Stores No Food Service Every 1000 SF 100 12 1,200 Lot #11 FUTURE / UNDEVELOPED Future Use GPD/ACRE 2338 1.5 3,507 Lot #12 R Leland Station Apartments Multifamily Dwelling 140 /dwelling 5 REQs Amenity 120 17,400 Lot #14R Cygnus Medical Office Employee/Shift 25 100 2,500 Lot #15 R Custom Home Furniture Furniture Store Employees/Shift Warehouse 25 / Employee 100 / Bay 16 2 600 Lot#17 FUTURE/UNDEVELOPED Future Use GPD/ACRE 2338 4.13 9,656 Lot#18 FUTURE/UNDEVELOPED Future Use GPD/ACRE 2338 3.03 7,084 Permitted Flow Lots 1-6 31,100 Permitted Flow Lots 7-18 67,640 Total Waterford Commercial Flow 98,740 GPD GPD GPD 3� 32 ' r- I ISSUED FOR REGULATORY REVIEW CAPE FEAR ENGINEERING 151 Poole Rd.,Suite 100; Belville, NC, 28451 TEL (910) 383-1044; FAX (910) 383-1045 www.capefearengineering.com N.C. LICENSE # C-1621 PROJECT NUMBER 650-43 SCALE AS SHOWN DATE WATERFORD COMMERCIAL OVERALL SEWER TRACKING EXHIBIT PROJECT NUMBER SHEET NUMBER 650-43 1 EX-1 100' 0 100' 200' / 1 INCH = 100' / NW tiW / 0 V O LOT c� 1 \� 6,16 LOT #7 B LOT L \ #2 \, \\ \\\\ LOT �/ , ;� % - Olde Regent Way Lq JL - IN,\ �y \�\ \ \ LOT LOT #8 LOT #9R \ oar Lot # Owner NCAC 2T Use 2T Design Units GPD/Unit/Day # Units Total Flow Lot#1 lweiis Fargo Bank Employee/Shift 25 7 175 Lot #2 Smithfield's Chicken and BBQ Restaurant, Single ServiceSeat Articles 20 100 2,000 Lot#3 Multi -Use (See Below) (3-1) Panera Bread Restaurant, Single Service Articles Seat 20 100 2,000 (3-2) Pivot Physical Therapy Medical, Medical Office Practioner/Shift 250 3 750 (3-3) Capelli Salon Beauty Shop Booth 10 125 1,250 (3-4) Your CBD Store Stores, No Food Service Every 1,000 SF 100 1.675 168 Lot #3 Total 4,168 Lot#4 Multi -Use (See Below) (4-1) Five Guys Restaurant, Single Service Articles Seat 20 50 1,000 (4-2) VACANT (AS OF 11/5/21) Stores, No Food Service Every 1,000 SF 100 1.675 168 (4-3) Club Pilates Fitness, Exercise Every 100 SF 50 16.75 838 (4-4) Intracoastal Reality Corporation Office Facility Employee/Shift 25 10 250 Lot #4 Total 2,255 Lot #5 Harris Teeter Fuel Station Employee/Shift 25 2 50 Lot #6 Multi -Use (See Below) (6-1) Islands Fresh Mex Grill Restaurant, Single Service Articles Seat 20 100 2,000 (6-2) Ultratan Beauty Shop Booth or Bowl 125 4 500 (6-3) Papa Johns Restaurant, Single Service Articles Seat 20 20 400 (6-4) The UPS Store Stores, No Food Service Every 1000 SF 100 1.4 140 (6-5) Mattress Emporium Stores, No Food Service Every 1000 SF 100 1.4 140 (6-6) Greatest Potential Chiropractic Medical, Medical Office Practitioner/Shift 250 2 500 (6-7) Splish Splash Dog Wash Beauty Shop * Booth or Bowl 125 4 500 (6-8) Wok & Roll Restaurant, Single Service Articles Seat 20 20 400 (6-9) Christophers Steak House Restaurant, Full Service Seat 40 100 4,000 (6-10) Computer Warriors Stores, No Food Service Every 1000 SF 100 1.4 140 (6-11) Falcone's Italian Restaurant Restaurant, Full Service Seat 40 50 2,000 (6-12) Beverly Nails Beauty Shop Booth or Bowl 125 4 500 (6-13) Great Clips Barber Shop Chair 50 8 400 (6-14) Luxe Home Interiors Stores, No Food Service Every 1000 SF 100 4.2 420 (6-15) Harris Teeter Shopping Center, w/ Food Service Every 1000 SF 130 48 6,240 (6-16) Jersey Mike's Restaurant, Single Service Articles Seat 20 20 400 (6-17) Alayna's Boutique Stores, No Food Service Every 1000 SF 100 1.675 168 (6-18) Hallmark Stores, No Food Service Every 1000 SF 100 1.675 168 (6-19) Dental Works Medical, Medical Office Practitioner/Shift 250 4 1,000 Lot #6 Total 20,015 A II OT I E 17 II II Hotel Hotel w/o I n-Room Room 100 110 11,000 FUTURE / UNDEVELOPED Future Use GPD/ACRE 2500 4.92 12,300 Corning Credit Union Bank Employee/Shift (+ 50 GPD for Public Restroom) 25 7 225 Shores Express Car Wash Car Wash Facility Based on Similar Faculties 3200 1 3,200 Goodwill Industries of Eastern INC, Inc. Stores No Food Service Every 1000 SF 100 12 1,200 FUTURE / UNDEVELOPED Future Use GPD/ACRE 2500 1.5 3,750 Leland Station Apartments Multifamily Dwelling 140 / dwelling 5 REQs Amenity 120 17,400 Cygnus Medical Office Employee/Shift 25 100 2,500 Custom Home Furniture Furniture Store Employees/Shift Warehouse 25 / Employee 100 / Bay 16 2 600 FUTURE / UNDEVELOPED Future Use GPD/ACRE 2500 4.13 10,325 FUTURE / UNDEVELOPED Future Use GPD/ACRE 2500 3.03 7,575 Permitted Current Future Flow Lots 1-6 (GPD) 31,100 28,663 2,438 Flow Lots 7-18 (GPD) 67,640 36,125 31,515 Total Waterford Commercial Flow (GPD) 98,740 64,788 33,953 Remaing Acres (Ac) 13.58 Allocation /Acre (GPD/Ac) 2,500 3� 32 ' r- I ISSUED FOR REGULATORY REVIEW CAPE FEAR ENGINEERING 151 Poole Rd.,Suite 100; Belville, NC, 28451 TEL (910) 383-1044; FAX (910) 383-1045 www.capefearengineering.com N.C. LICENSE # C-1621 PROJECT NUMBER 650-43 SCALE AS SHOWN DATE WATERFORD COMMERCIAL OVERALL SEWER TRACKING EXHIBIT PROJECT NUMBER SHEET NUMBER 650-43 1 EX-1