Loading...
HomeMy WebLinkAboutWQ0037341_Regional Office Historical File Pre 2018NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, 111 Governor Secretary Mr. Neil Kapadia Brookline Residential, EEC 3800 Pomfret Lane Charlotte, NC 2821 1 Subject September 18, 2014 Permit No. WQ0037341. Brookline Apartments Wastewater Collection System Extension Mecklenburg County, NC Dear Mr, Kapadia: In accordance with your complete application received September 17, 2014, we are fOrwarding herewith Permit No. WQ0037341, dated September 18, 2014, to Brookline Residential, EEC for the construction and operation of the subject wastewater collection system extension. This perrnit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this perrnit and are therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: ConditioDII.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the .Permittee. It shall be responsibility of the Brookline Residential., LTC to ensure that the as -constructed project meets the appropriate design criteria and rules. Failureto comply may result in penalties in accordance, with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition. conforming to Chapter 15013 of North Carolina General Statutes, and filed with the Office of ,Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-67'14. Unless such demands are made, this permit shall be final and binding, 1E11 Mali Service Center, Raleigh, North Carolina 27699-1611 Location,: 512 N, Salisbury Si Ralegh, North Carolina 215-14 Phone! 919-607-6300 FAX 9194301-6492 Internet vivivy,nowaterResaurces,orq An Equal Oppotinily Ah.rnaVve Action Employer Mr. Neil Kapadia September 18, 2014 Page Two If you need additional information concerning this matter, please contact Michael Parker at (704) 235- 2194 or via e-mail at Michael.Parker@ncdenr.gov. for Thomas A. Reeder Division of Water Resources by Michael L. Parker Surface Water Protection Supervisor Mooresville Regional Office Electronic copy: Steven S. Wilson, P.E. cc: Mooresville Regional Office, Surface Water Protection Section Water Resources Central Files PERCS (e- copy) Barbara Gross (e-copy) Willis Horton (e-copy) r ATA NCDENR STATE OF NORTH CAROLINA' ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Brookline Residential, LLC for the construction and operation of approximately 2,167 linear feet of 8-inch gravity sewer to serve the Brookline Apartments development, and the discharge of 44,200 gallons per day of collected domestic wastewater into the McAlpine Creek WWTP existing sewerage system, pursuant to the complete application received September 17, 2014, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. ermit issued this the 18th day of September, 2014. for Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0037341 SUPPLEMENT TO PERMIT COVER SHEET Brookline Residential, LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the McAlpine Creek Wastewater Treatment Facility prior to being discharged into the receiving stream.. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of .Pump Stations and Force Mains adopted June 1., ROO as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS 1. If; at any time, the additional wastewater flow vohune made tributary to this sewer extension is believed to exceed the value permitted herein, a modification shall be requested for this permit from the Division of Water Resources to property allocate the subject wastewater flow. 2. No .flow in excess of the quantity permitted herein, 44,200 .CiPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Water Resources.. II. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Perrnittee, a formal, permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15.A. NCAC 2T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as appii.cabl.e; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting .materials unless specifically mentioned herein. 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application, and other supporting data. 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by I5A NCAC 2T ,0403, If an individual permit is not required, the following performance criteria shall be ,net as provided in 15A NCAC 2T .0403: I a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface. waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a.telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. Noncompliance Notification: The Permittee shall report by telephone to a Water Resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is perrnissihle, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-O36.8 or (919) '733-3300, Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part 1 of Form CS-SSO (or the most current Division approved form) within five days following first: knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur, Part 11 of Form CS- SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control, 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, 7. Per I5A NCAC; 2T_01 ] 6, upon completion of construction and prior to operation of these permitted 'facillities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form.. A complete certification is one where the dorm is fully executed and the supporting documents are provided as applicable„ Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entityfi with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and. Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, Supporting documentation shall include the followinl;i One copy of the project construction record drawings (plan &. profile views of sewer lutes & forcemains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defned as the design drawings that are marked up or annotated with after construction information and ,shorty required butf"ers, separation distances, material changes, etc: One copy of the supporting pump station design calculations (selected pumps, system curve, operating point, buoyancy calculations, available storage if portable generator(s) or storage greater than longest 'past three year outage reliability option, selected,) for any pump stations permitted as part of tk'ris project. Changes to the project that do not result in non-compliance' vvtith this permit, regulations, or the Minirunt Design Criteria should be clearly identified on the record drawings, on the certiitication in the space provided, or in written sutnunary form. Prior to Certification (final or Partial.): Permit modifications are required for any changes resulting iut non compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the nurn.ber/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation, A copy of the construction record drawings shall be maintained on file by the Perniitt.ee for the life of the wastewater collection facilities. rir 9. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the Licensing board. 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. FAST TRACK ENGINEERING CERTIFICATION Permittee: Brookline Residential, LLC Permit No. WQ0037341 Project: Brookline Apartments - Mecklenburg County Issue Date: 09/18/2014 Complete and submit this form to the permit issuing regional office with the following • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are re wired for an chap es resultin in non -corn fiance with this omit re ulations or minimum design criteria. Modifications should be submitted prior to c+rt€fication. This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore it is hi hl recorxrended that this certification be sent _in_a manner that provides roof of receipt by the Division. PERMITTEE'S CERTIFICATION Io the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name„ Title Signature Date ENGINEER'S CERTIFICATION Partial ❑ Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS SURFACE WATER PROTECTION SUPERVISOR MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. i DWQ Use. Only: Flow from this pa STATE OF NORTHAROLINA �� �t�3 �`� COUNTY OF P O(e fl h .1Permit No. / DEV(( ELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (d 1) and entered into this /.. +11 day of A V (J SI) 2,o i , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and �jf'ool�.��r�' P-e5i oil / / Li (� , a corporation/general partnership registered/licensed to do business in the State ofNorth Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands Iying in //Irby-IC'I hart. County, upon which it is erecting and will erect dwelling units and other improvements, said devil opment to be known as 81-061,4(!l1 e (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.I to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and hands through filing of a Declaration of Unit Ownership (hereinafter DecIaration), pursuant to Chapter 47C or47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to/�be formed at the time of filing of the Declaration, the J i i g1cC�QKLIJJE AprgrM&-Jt> HOA (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters ofthe State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1 The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor_ FORM: DEV 08-13 Page 1 of 2 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance dale system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance, 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund he created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment andlor disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this representative of the parties hereto FOR THE ENVIRONMENTAL GEMENUOMMISSION omas A. Reeder, Director Division of Water Resources (Date) .e7 FORM: DEV 08-13 agreement was executed in duplicate originals by the duly authorized on the day and year written as indicated by each of the parties named below: ,a5 kG ".. sW5v 9 Name of DEVELOPER B (Signature) /ve,t /c:77.re,"� Print Name and Title (Date) Page 2 of 2 /. la. 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Application Number: (to be completed by DVVR) X373 Owner/Permittee: Brookline Residential, LLC Full Legal Name (company, municipality, HOA, utility, etc.) Neil Kapadia, Owner Signing Official Name and Title (Please review 15A NCAC 2T .0106.1t) for authorized signing officials) The legal entity who will own this system is. El Individual E Federal El Municipality Ej State/County El Private Partnership El Corporation Other (specify). Q 1d. 3800 Pomfret Ln U— Mailing Address lf, NC State O ih 704-995-4180 li. 704-972-2699 - Telephone Facsimile 2. Protect (Facility) Information: ..jt 2a Brookline A artments Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Tom Grasse Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-972-2673 3c Torn Brasse@f&soncorn ___ le, Charlotte City 19. 282.11 Zip Code 1j, snkapadiaA2mail„com E-mail . 2b. Mecklenburg County Where Project is Located Phone Number E-mail 1 Project is El New D Modification (of an existing permit) If Modification, Permit No.: 2, Owner is 0 Public (skip to Item B(3)) Z Private (go to item 2(a)) 2a, If private, applicant will be; 0 Retaining Ownership (i,e. store, church, single office, etc.) or [El Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 13 Selling units (lots, townhomes, etc. - go to Item B(2b)) 2b. If sold, facilities owned by a (must choose one) Ej Public Utility (Instruction D) Z Homeowner AssoODeveloper (Instruction E) 3. _Charlotte-Meckjenburg Utilities_ _ _ Z..... Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project L) 4a. McAlpine VVWTP 4b. NC0024970 Name of WWTF WWTF Permit No 5a. CMUD t5b, 8 tg Gravity },5c, 202-568 , Owner of Downstream Sewer iReceiving Sewer Size 0 Force Main , Permit # of Downstream Sewern n F 6. The origin of this wastewater is (check all that apply): LJ Residential Subdivision El Apartments/Condominiums Ej Mobile Home Park 0 School o Restaurant D Office 7 Volume of wastewater to be at or fl Retail (Stores, shopping centers) 0 Institution ED Hospital El Church 0 Nursing Home El Other (specify): 100% Domestic/Commercial % Industrial (Attach Description) % Other (Attach Description) ed for this particular project: 44,200 gallons per day *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: 1:1 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. D Rehabilitation or replacement of existing sewer with no new flow xpected (see 15A NCAC 02T 0303 to determine if a permit is required) FTA 08-13 APPLICATION Page 4 of 6 Provide the wastewater flowcalculations used in determining the permitted flow in accordance with 15A NCAC 2T2T t4 for the value in Item B(7) ANDIOR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 320 apartments @ 135 gpd + 100 person amenity area @ 10 gpd = 44,200 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8 2,167 z 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) z Pump Station Location ID Longitude: New Gravity or Additional Force Main New gravity z 0 0 (self chosen - as shown on plans/map for reference) Latitude: Design Flow Operational Point Power Reliability Option (MGD) GPM TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Location ID: hosen - as shown on plans/mance) Longitude: Latitude: Design Flow Power Reliability Option (MGD)3perational Point 1 - permanent generator w/ATS; Force Main Size Force Main Length GPM @TaH 2 - portable generator w/MTS Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? Q Yes No If Yes, permit number of 2"tl treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria Jot the Permitting of bump Stations and ForceI ains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable?? I.dl Yes © No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT Two COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 08-13 APPLICATION Page 5 of 6 14. Have the folio permits/certifications been submitted for approval for the system or project to be served? Wet/and/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Trout Buffer Waiver' Storrnwaler? 15. Does this manholes project Include any high priority Tines ? These t1n s.�vjlt_be consider d t eck if Yes: 0 and provide details: Owner/Permittee's Certification: (Signature of 1, Neil Kaoadia has been reviewed by me and is accrete an« parts of this application are not completed art included, this application package is subject to General Statutes 143-215. ¢A and 14, 3-,215,68, certification in any application shalt be guilty of es well as civil penalties up to $25,000 per viola Signing Ciffieittt Signet: e 1 SA NCAC 02T .f 4 O Yes El No [ NIA Yes D No ©N/A [ Yes [J No NJA IN Yes O No D N/A aerial lines, d onceever Signing Official and Project Name) , attest that this cheek rtkn for Brookaate Apartments 1 complete to the best of my knowledge. l understand that if all required d float if all required supporting documentation and attachments are not being returned es incomplete_ Note: In accordance with North Carolina any person who knowingly makes any false statement, representation, or a Class 2 misdemeanor, which may include a fine not to exceed $10,000 Lion. ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY Z TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC, REFER TO 15A NCAC 02T .0305 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) n - Wilson ,attest that this application for Bropkline Apartments been reviewed by me and is accurate, cornplete and consistent with the information in the engineering plans„ ulations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has bean prepared In accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance Although other professionals may have developed certain portions of this submittal package, inclusion of these materiels under my signature and seal signifies that f have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-,215,5A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per , _`4 Cpn�Eh� 2a, Steven 5. Wilson `r"tA CAP fessionai Engineer Name 2b. Landworks design Group P,A, Engineering Firm 2c. 7621 Little AvemueSuite 1 Mailing Address 2d. Charlatt 2e. NC 2f. 28226 City State Zip 2g_ 704-841-16fi4 2h. 704-841-1604 2i. swiison landworkspa.com E-mail Telephone Facsimile FTA 08-13 APPLICATION Page 13of6 a Statement; i t" certify to the best of my knowledge that. the addition of the voluatte ofiwastewater t. a be permitted in this project has been evaluated along the route to the receiving wastewater treatment Iaciand that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under norn3al circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the 'best available data. This certification applies to those items Fisted above in Sections 1 and 1.1 plus all attached planning assessment addendunis for which I am the responsible party, Signature of this form indicates acceptance of this wastewater flow, 2 of 6 VISE 08-I Submit a planni Capacity is < 0, FTSE PI:,ANNING ASSESSMENT AI'DENDUM (PAA) assessment addendum for each pump station Pump Station (Natrae crr Number): Given that, a. The proportion and amount of Obligated, Not 3 . s °4 and : s d in Section II where Available Tributary Daily Flow (C) accounts for MCI) ofthe Available. Capacity (E) in Purnp Station Paw Creek ; and that of activation cif this obligated, not yet tributary capac 1 s 1+ It. I) per year; and that c. A funded Capital Project that will provide the required planned capacity. namely "', tr .A "t.ac,renc is in design or under construction we planned completion in e,r - d. The following applies: cMUT Capital 24' fora main. with a .larger 36'° d.iautete,eemain, and a 5 million gallon Cl2 basi at Long Cr k Pump St: ,g. . 'Long Creek and Paw Creek pump stations. operate as a system u:tinq SCaDA data to ll has a] and/or 7k, y' approximately aw Creek determine the rate of flow delivered from the upstream pump station, Long Creek, to Paw Creek the downstream facility. Long Creek pump station has the abili.ty to transfer flows tanks during peak flow events and then meter nut flow to Paw Creek as to flow equal flow cond#.t,iars :azl .. In addition, the basin„s for both static na rs.rt. large and result a daily peaking factor of 2.06 at Paw Creek Pusip Station, which allows the stations to operate safely thee. 404 of the firth pumping nat-tanity. Therefore: Given reasonably expected conditions and planning information, there is suf1icient justification to allow this flow to be permitted., without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143--215.670) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. //! Date 6 BROOKLINE APARTMENTS SITE NOTES: USGS Color Topo for FTA 08-113 Downstream Sewer Info: GMUD owned, 8" Gravity SS, Permit #202-568 Open in The National Map Viewer 9/2/14 9:36 AM Polaris 3G Map Mecklenburg County, North Carolina Brookline Apartments Date Printed: 9/2/2014 `t :03:43 AM port rs pr epare. or t e nventory c rea property wit rn eckle nburg Coiirify and rs comp ed flora repor ed aps, and other public records and data. Users of this map or report are hereby notified that the aforementioned pu primary i or verfication. Mecklenburg County and its mapping contractors assume no legal responsibility for the information canter ps survey urces FORM WSCAS 08-13 WATERSHED CLASS F CATION ATTACHMENT FOR SEWER SYSTEMS nt Name Brookline RAsidential. Lt-C ProfeeSional trtgineer Name Steven S. Wilson Location ID T Pro ect Name Apartments ineering Firm Name prks n Group. PA River Waterbody Stream Waterbody Name of Waterbodyl County Basin Index No. Classification TriltetSty Leng Oteek Mtitt4044-eg 111-12040-5) 1 II unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. I certify that as a Registered Professional Engineer in the State of North Carolina that 1 have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS 08-13 *** FORM: WSCAS 08-13 Page f Landworks Design Group, PA 7621 Little Avenue, Suite 111 Charlotte, NC 28226 Memorandum Date: September 3, 2014 To: NCDENR From: Landworks Design Group, PA Steven S. Wilson, PE Project: Brookline Apartments Job* 13046 Re: Brookline Apartments Private Sanitary Sewer Narrative Telephone: 704-841-16044 Facsimile: 704-841-1604 The proposed Brookline Apartments will be a planned multi family residential apartment development serving 320 apartment homes including a community clubhouse/pool amenity area. This project will consist of approximately 2,167 LF of 8" private gravity sewer and related appurtenances, which will connect to an existing 8" public gravity sanitary sewer trunk. The estimated sewage flow from this project is 44,200 GPD based on the following calculations, 320 apartments © 135 gpd + 100 person amenity area @ 10 gpd = 44,200 gallons per day. Landworks Design Group, P.A. Steven S. Wilson. PE P:42Q13 Jnbs113046 Brookline ApartmentsDocurnentsISEWER AND WATER FORMS AND DATA ovate sewer water app/ications4D WQ - Fast Track Narrative.docx State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: ,and P ks Des±gn Group Project. Name for which flow is being requested: Brookline More than one FTSE may he required/or a single prciject if the owner of the is no. es. PLC. stations along the route qf the proposed wastewater flow, 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek 'WWTP b. WWII) Facility Permit NC0021970, NC002494 5, NC0024937 c. WWTP facility's permitted flow Wows are in GD 99.0 d. Estimated obligated flow not yet tributary to the WWTP 10.192 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility 7 0_057 77.034 h. Percent of permitted flow used 77,0$ 11, Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. 1„,ist pump stations located between the project connection point and the WWTP: (Al (Ft) (C) (D)---(B+C) (E)(A-I)) Design Obligated, Pump Average Daily A.pprox, Not Yet Total Current Station Firm Flow** Current Avg., Tributary Flow Plus (Name or Capacity.* (Firm I pt), Daily Flow. Daily Flow, Obligated Available Number) MGD MGD MOD MGD Flow Capacity*** Long CreI 1,0,100 1.01sis 0,154 3.622 0.417 Paw Creek 11.300 4.52 4.352 * The Firm Capacity 0.175 ny pump station is defined as the maxi u -0=007 ped flow can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Page I of 6 )8- 3 Landworks Design Group, P.A. 7621 Little Avenue, Suite 111 Charlotte, NC 28226 Memorandum Date: September 15, 2014 To: Mike Parker NCDENR — Mooresville Regional Gffice 610 E. Center Ave. Mooresville, NC 28115 From: Landworks Design Group, PA Steven S. Wilson, PE Project: Brookline Apartments Job #: 13046 Re: Brookline Apartments Private Sanitary Sewer Dear Mike, Telephone, 704-841-1604 Facsimile: 704-841-1604 On behalf of Brookline Residential, LLC, NC we are submitting revised Fast -Track Application (FTA C18- 13) for gravity sewers along with Private Sewer Plans for the construction of "Brookline Apartments" private sanitary sewer and related appurtenances. (2) Copies of application FTA 08-13, narrative, operational agreement, flow tracking worksheet, maps and watershed classification form. Appropriate forms have been signed by Neil Kapadia We look forward to your favorable review and approval of the proposed construction. Should you have any questions or if we may aid in your review, please feel free to contact me at 704.841,1604. Yours very truly, Landworks Design Group, PA. Steven S. Wilson, PE P.42013 Jobs113O46 - Brookline Apartments\Bocuments4SEWER AND WATER FORMS AND OATA1priivafe sewer water a ppllcatrons4DENR Submittal Memo 9.15.14.docx Central Files: APS — SWP _ 9/18/2014 Permit Number WQ0037341 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer michael.parker Coastal SWRuIe Permitted Flow 44,200 Facility Version Permit Classification 1.00 individual Permit Contact Affiliation Facility Name Brookline Apartments Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Brookline Apartments LLC Dates/Events Owner Type Non-Govemment Owner Affiliation Neil Kapadia 3800 Pomfret Ln Charlotte NC 28211 Orlg Issue 9/18/2014 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/8/2014 9/18/2014 9/18/2014 Regulated Activities Requested /Received Events Apartment complex Additional information requested 9/9/14 Condominium Additional information received 9/17/14 Wastewater collection Out -fall Waterbody Name Streamlndex Number Current Class Subbasin RECF V DINCOENB!DWR FAST TRACK 'ENGINEERING CERTIFICATION Permittee: Brookline Residential; LLD , Permit No, WQ0037341 Project: Brookline Apartments — Mecklenburg County CEf i E issue Date: 0.9/1812014 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the n odtfications re re t (r d. for anv, changes resuttl in orr o rninirraurrs dttsirrt criteria, Modifications should be ubrr►ltted trig d drawings or in written summary form, Permit This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore, it is highly recommended that, this certification Pe sent In a maker that provides proof of receipt by the Division PERMFTTEE'S CERTIFICATION ij the undersigned agent for the Permittee, hereby state that this project has been constructed pursuan to the appiicable standards & requirements, the Professional Engineer below has j provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & ' maintain the wastewater collection system permitted herein or portions thereof, r,, .440144(1 ill ii- Title S t ts, © Partial Final I,„ �+ as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (N periodically, weekly, El full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, NGINEER' CERTIFICATION Date North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOW4NG ADDRESS SURFACE WATER PROTECTION SUPERVISOR MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions DAA,0 Use Offiy: How from this p•oj, ct is tribui,: rto: Landworks design Group, P.A. 7621 Little Ave., Suite 111 Charlotte, NC 28226 Transmittal Date: 5/19/15 To: NCDENR Surface Water Protection Supervisor -Michael Parker Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Re: Brookline Apartments — Wastewater Collection System Certification Proj.No:13048 Via: Fedex Telephone: 704841-1604 Facsimile: 704-841-1604 RECEI1/EDINCDENPIDWR 21 '015 *OROS MOORESWDLLE REGIONAL OFFICE Far Approval As Requested _Return for Corrections El For Review Approved as Submitted Resubmit Copies for Approval For Review & Comment j Approved as Noted 0 Submit Copies for Distribution Copies Date No. Description 1 5%15/15 1 5,114/15 1 5/19/15 1 Page 3 Sheets Fast Track Engineering, Certification — W00037341 As -Built Plans & Profiles (L-600, 602, 603) CD w/ PDF of Complete Certification Package Remarks: From: Steve Wilson Cc: