Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0037057_Regional Office Historical File Pre 2018
sr, Ncb North Carolina Department of Environment and Natural Resources Pat McCrory John E, S varla, III Governor Secretary May 1, 2014 Larry D. Estridge Steele Creek (1997) Limited Partnership 6100 Fairview Road, Suite 640 Charlotte, NC 28210 Subject: Permit No. WQ0037057 Steele Creek (1997) Limited Partnership Steele Creek Retail Center Wastewater Collection System Extension Mecklenburg County Dear Mr. Estridge: In accordance with your application received on March 28, 2014, we are forwarding herewith Permit No. WQ0037057, dated May 1, 2014, to the Steele Creek (1997) Limited Partnership for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this per Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be responsibility of the Steele Creek (1997).Limited Partnership to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or Iimitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Mooresville Regional Office, 610 East Center Avenue, Mooresville, North. Caroli a 2 e: 04-663-16991 Internet: v+wvay.ncdenr,gov An Equal OpArfirrnerive Action Empioyer— Made in part by iecya,led paper Steele Creek (1997) Limited Partnership WQ0037057 If you need additional information concerning this matter, please contact James Bealle at (704) 663- 1699 or via e-mail at james,bealle@ncdenr.gov. for Thomas A. Reeder Division of Water Resources by Michael L. Parker Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office cc: Kristopher W. Rowe, P.E., LandDesign Mooresville Regional Office Water Resources Central Files PERCS (electronic copy) I Ara NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Steele Creek (1997) Limited Partnership Mecklenburg County for the construction and operation of approximately 1,180 linear feet of 8-inch gravity sewer as part of the Steele Creek Retail Center project, and the discharge of 16,775 gallons per day of collected domestic/commercial wastewater into the McAlpine Creek WWTP existing sewerage system, pursuant to the application received March 28, 2014, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. Permit issued this the 1st day of May, 2014. for Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0037057 SUPPLEMENT TO PERMIT COVER SHEET to - Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater coUeCtedbvthissystemsha||betreatedinthmMcA|pine[neekVVastewnter Treatment Facility (NCO024970) prior to being discharged into the receiving stream. Permitting of this project dues not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of pump Stations and Force Mains adopted June 1, l00Oosapplicable, unless specifically mentioned herein. Division approval in based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Perrnittee'xresponsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. . SPECIAL CONDITIONS L If, at any time, the additional wastewater flow volume made tributary to this sewer extension is believed to exceed the value permitted herein' a modification shall be requested for this permit from the Division of Water Resources 10properly allocate the subject wastewater flow. [I. STANDARD CONDITIONS 1. This permit shall not betransferable. |nthe event there isadesire for the wastewater collection facilities \o change ownership, prthere baname change of the Pe/mittee,aformal permit request shall besubmitted vo the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. Z. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit,- l5A NCAC J'% the Division's Gravity Sewer Minimum Design [/de,im adopted February 12' 1996 asapplicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1' 2000 as applicable; and other supporting materials unless specifically mentioned herein. I This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The wastewater collection facilities shall beproperly maintained and operated atall times, The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by I5A NCAC 2T .0403. |fam individual permit is not required, the following performance criteria shall be met as provided in 1SA NCAC 2T .0403: a, The ,ewer system shall baeffectively moVntainedamd operated at all times Loprevent discharge tmland or b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. Noncompliance Notification: The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical. failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or of xedinformatiori is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part! of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form ^ C5-SS0 (or the most current Division approved form) can also be completed to show that the SSOwus beyond 6 Construction cfthe gravity sewers, pump stations, and force mains shall bescheduled y»asnot tuinterrupt service by the existing utilities nor result in an overflow o/ bypass discharge ofwastewater to the surface waters nfthe State. 7. Per 15A NCAC 2T.0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tuthe address provided onthe form. Acomplete certification isone where the form is fully executed and the supporting documents are provided asapplicable, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, If the permit is issued to a private entity with an Operational Agreement, then a copy pfthe Articles of |ncwrporat|mn,Declara¢imns/Covenants/Restricdons, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) ofthe wastewater collection system extension. Final record drawings should be, clear un the plans or on digital media (CD or DVDdisk) and are defined asthe design drawings that are marked mporannotated with after construction information and show required buffers, separation distances, material changes, etc b� one copy ufthe supporting pump station design calculations (selected pumps, systemcurve, operating point, buoyancy calculations, avaiiab|e storage if portable generator(s) orstorage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project. Changes cothe project that donot result innon-compliance with this permit, regulations, ortheMinimum Design Criteria should beclearly identified on the record drawings, on the certification |nthe space provided, orimwritten summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non- compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 596 or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications o/ variances to the Minimum Design Criteria will be reviewed on acasm-by-casebasis and each on its own mneric Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. @. Ampy ofthe construction record drawings shall bemaintained on file by the Permittee for the life of the wastewater collection faciRies, 9. Failure toabide by the conditions and limitations contained bnthis permit; 15AmCA[ZT|the Division's Gravity ---- Scvc-r(DasignCriteria adopted February 1Z,1996vsapplicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June l, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, I • 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General. Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. FAST TRACK ENGINEERING CERTIFICATION Permittee: Steele Creek (1997) Limited Partnership Permit No, WQ0037057 Project: Steele Creek Retail Center Issue Date: 05/01/14 Complete and submit this form to the permitissuing regional office with the following. • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit regulations or minimum design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. PERMITTEE'S CERTIFICATION 1,, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Ti le Signature ENGINEER'S CERTIFICATION Date EJ Partial LJ Final 1, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (LJ periodically, El weekly, EJ full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal, signature, and date; SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS DIVISION OF WATER RESOURCES WATER QUALITY REGIONAL OPERATIONS SECTION MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, STATE OF NORTH CAROLINA COUNTY OF MECKLENBURG Permit No. CC--Q ao 37a 57 DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (dl) and entered into this ! S } day of , 2014 by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Steele Creek (1997) Limited Partnership, a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in Mecklenburg County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as Steele Creek Retail Center (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143-215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the Steele Creek Retail Center Association (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of Slate of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL Thomas A. Reeder, Director Division of Water Resources (Date) 5,-412.0/ Steele Creek (1997) Limited Partnership Name of DEVELOPER By. ('it. attire) Larry Estridge. General Counsel Print Name and Title 41 (Date) 0 2 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD OwnerfPerrnttee: la, Steele Creek (1997) Limited Partnership Full Legal Name (company, municipality, HOA, utility, etc.) 1b. Larry Estridge, General Counsel Signing Official Name and Title (Please review 15A NCAC 2T0 lc, The legal entity who will own this system is: 0 Individual 0 Federal 0 Municipality ❑ State/County ld, 6100 Fairview Road, Suite 640 Mailing Address if, North. Carolina Application Number: (to be completed by DWR) 6 (b) for authorized signing o cials) Private Partnership 0 Corporation 1 e. Charlotte State 1 h, 704-342-9039 Telephone 2. Project (Facility) Informati+nta. 2a. Steele Creek Retail Center Brief Project Name (permit will refer to this name) 3. Contact Person: 3a, Kris Rowe, PE Facsimile Other (specify): City 1 g28210 Zip Code lestridge@wcsrcom E-mail 2b. Mecklenburg County Where Project is ocated Name and Affiliation of Someone Who Can Answer Questi 3b. 704-333-0325 Phone Number Project is ❑ New Modifia anon (of an existing permit Owner is ❑ Public (skip to Item B(3)) ® Priv ns About this Application 3c. krowe c@landdesign.com E-mail If Modification, Permft No.: e (go to Item 2(a)) 2a, if private, applicant will be 0 Retaining Ownership (Lestore, church, single office, etc,) or 0 Leasing units (lots, townhomes, etc, - skip to item B(3)) Selling units (lots, townhomes, etc. - go to Item B(2b)) Charlotte-Mecklenbur Utilit Cie ariment 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction D) ( Homeowner Assoc./Developer (Instruction E) 0 Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, McAlpine Creek Wastewater Treatment Plant 4b. NC0024970 Name of WWTF WWTF Permit No, C 5a. Charlotte -Mecklenburg Utility 5b, 8" Owner of Downstream Sewer Receiving Sewer Size LL Z 6. The origin of this wastewater is (check all that apply): El Residential Subdivision Apartments/Condominiums El Mobile Home Park ❑ School 0 Restaurant 0 Office Gravity Force Main Retail (Stores, shopping centers) Institution El Hospital Church Nursing Home 0 Other (specify): 7, Volume of wastewater to be allocated or permitted for this particular project: 16,775 *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why ntrears Sewer (Instruction F) 100% Domestic/Commercial Industrial (Attach Description) % Other (Attach Description) gallons per day © Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line Flow has already been allocated in Permit No, El Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCACO2T ,03O3 to determine if a permit is required) FTA 08-I: APPI_.1CA"l" ON Page 4 of 6 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 1;5A NCAC 2T .0114 fear the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f).. 27,500 sf x 130 gpol1,000 sf = 3,575 gpd 110 room hotel x 120 gpolroom = 13,200 gpd 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8 1,180 New Gravity or Additional Force Main New Gravity Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) z a Pump Station Location ID: (self chosen - as shown on plans/map for reference) "-' Longitude: Latitude: Z 0 Design Flow Operational Point Power Reliability Option (MGD) GPM @TDH 1 - permanent generator WATS; 2 - portable generator wfMTS Force Main Size Force Main Length 0 IL. Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow OpPoint Power Reliability Option (MGD) GPM QTDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator wfMTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? © Yes ►1t, No If Yes, permit number of 2nd treatment facility (RO - if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the tvliniq um Design Criterl for the Permif Pump Stations and Force Mains (latest version), the Gravity, Sewer Minlrrurr: DesignCriteria(latest version) and 15A NCAC Chapter 2T as applicable? Yes 0 No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION PTA 08-13 APPLICATION Pa e5 of 6 4. Have the following permit certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? El Yes D No ❑ N/A Sedimentation and Erosion Control Pian? IN Yes D No El N/A Trout Buffer Waiver? (Q Yes © No N/A Stormwater? LA Yes ID No [1 N/A 15. Does this project include any high priority lines (15A NCAC 02T ,0402 (2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six month% heck if Yes: 0 and provide details: Owner/Perrnittee's Certification: (Signature of Signing Official and Project Name) 1, Larry Estridge General Counsel, attest that this application for Steele Creek Retail Center has been reviewed by me and is accurate and complete to the best of my knowledge, 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, thisapplication package is subject to being returned as incomplete, .Note: In accordance with North Carolina General Statutes 143- 215.6A and 143-215. B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well es civil penalties up to $25, 000 per violation. ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF miS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC, REFER TO 15A NCAC 02T .0305 Professional Engineers Certification: (Signature of Design Engineer and Project Name) 1, Kristopher W, Rowe, PE ,attest that this application for Steele Creek Retail Center has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge, l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 1 + -215. 6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25,000 per violation.. Kristopher W, Rowe, PE Professional Engineer Name b. LandDesign -, Engineering Firm 223 North Graham Street Mailing Address d, Charlotte City 704-333-0325 Telephone NCZf. 28202 State Zip 704 33 3245 i krowe@landdesign.com E-mail FTA 08-13 APPLICATION Page 6 of 6 Division of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: LandDesign Project Name for which flow is being requested: Steele Creek Retail Center More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek WWTP b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 99.0 9.961 66.785 0.0168 76.746 77.50 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** seaverdam Creek 2.70 1.08 0.07 0.061 0.131 0.949 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of 6 FTSE 08-13 I1I. Certification Statement: 1 p_,cry kCa.r-c certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendurns for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Offrcikl Signature Page 2 of 6 z127MI Date FTSE 08-13 5/8/13 G©agle Maps Charlotte Premium Outlets htlps:/Jmaps.g aggle.comfmaps?N=en&le=UTFB&t1=35.167108; 80.96956&spr 0.014717,0.61929&1=h&z=168vpsrc- 6&ei=MGuKl. MONKgwalftkd)gDv .4p... 1/1 FORM WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS onal Engineer Name Kristapher W. Rowe, PE LandDesign Location I© Name of W►aterbody' Unnamed Tributary to Beaverdam Creek aunty ittburg River Basin Catawba aterbody Stream Waterbody Index No. Classification If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary icrins. I certify that as a Registered Professional Engineer in the State of North Carolina that I have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief, PE Seal, Signature and Date *** END OF FOR WSCAS-12/07 *** FOR : 'SCAS-12/O7 Page 0 March 1 3, 2014 ENGINEER'S REPORT Steele Creek Retail Center LDI Project No. 1012348 SEWER SYSTEM APPLICANT: Steele Creek (1997) Limited Partnership 6100 Fairview Road, Suite 640 Charlotte, NC 28210 DEVELOPER: Steele Creek (1997) Limited Partnership 6100 Fairview Road, Suite 640 Charlotte, NC 28210 DESCRIPTION: The site consists of ±15 acres. The property is zoned CC and will consist of approximately 27,500 square feet of retail space and a 110 room hotel, We are proposing to install ±1,180 if of 8" PVC sewer main on -site that will make up the private system, Flows from the project will be sent to the McAlpine Creek Wastewater Treatment Plant (NPDES permit number NC0024970), SEWER SYSTEM IMPROVEMENTS: The proposed demand for this site will be approximately 16,775 gallons per day. The demand is based on 27,500 sf retail space at .1.30 gallons per day11.,000 sf and 110 room hotel at 120 gallons per daylroom. New mains are expected to have a minimum 50-year service life. The system will be constructed by the Developer and sewer services will be billed by the City of Charlotte in accordance with their standard rate schedule. Na '2012w101234800CS4PERM [TTINMPERMV FORAISIPRIVATE SEWERV'1012348-ENGINEE REPORT WdATER.DOC LAIJDDESkGN. INC. PR : ,JE ::'' 1013218 STEELE CREEK RETAIL CENTER 1013218 Steele Creek Retail Center For your review and comment Kris Rowe 223 North Graham Street Charlotte, NC 28202 NCDENR - Mooresville Regional Office Water Quality Section 610 East. Center Avenue Mooresville, NC 28115 andDesign, Inc. TRANSMITTAL OD, Transmittal 3/27/2014 00008 Overnight krowenddesign.com 704-333-032 noneinone.com 704-663-1699 Enclosed is a fast -track application submittal package for the Steele Creek Retail Center located in the City of Charlotte, Mecklenburg County. Please feel free to contact me if you have any questions, Sincerely, Kris Rowe DATED Fast -Track Sumittal Packages, Check in the amount of $480.00 (#2103) North Carolina Secretary of State Page 1 of 1 • n Account Login Register c�n11 3ro]Iiia SPAR I 'NT OF THE Secretary SECRETARY OF STAV-- PO Fox 29 22 C, Icit#t. NC 27hi264i?2. 019p. 7-2,IM • Date: 3/31/2014 Click here to: View Document Filings PC, PLLC, LP and Non -Profit entities are not required to file annual reports. Corporation Names Name Name Type NC STEELE CREEK (1997) LIMITED LEGAL PARTNERSHIP Limited Partnerships Information SOSID: 1368995 Status: Current -Active Effective Date: 5/13/1997 Dissolution Date: Citizenship: FOREIGN State of Inc.: DE Duration: PERPETUAL Registered Agent Agent Name: Office Address: CT CORPORATION SYSTEM 150 FAYETTEVILLE ST., BOX 1011 RALEIGH NC 27601 Mailing Address: 150 FAYETTEVILLE ST., BOX 1011 RALEIGH NC 27601 Principal Office Office Address: 6100 FAIRVIEW ROAD, SUITE 640 CHARLOTTE NC 28210 Mailing Address: 6100 FAIRVIEW ROAD, SUITE 640 CHARLOTTE NC 28210 Officers/Company Officials This website is provided to the public as a part of the Secretary of State Knowledge Base (SOSKB) system. Version: 2656 http://www.secretary.state.nc.us/corporations/Corp.aspx?PitemId=10483399 3/31/2014 • Central Files: APS SWP 5/1/2014 Permit Number WQ0037057 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Version Permit Classification 1.00 Individual Primary Reviewer Permit Contact Affiliation james.bealre Coastal SWRuIe Permitted Flow 16,775 Facility Facility Name Steele Creek Retail Center Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Steele Creek 1997 Limited Partnership Dates/Events Owner Type Non-Govemment Owner Affiliation Larry Estridge 6100 Fairview Rd Charlotte NC 28210 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 5/1/2014 3/28/2014 5/1/2014 5/1/2014 Regulated Activities Requested /Received Events Retail Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamlndex Number Current Class 5ubbasln RECEIVEQN Srvl21 '0111 FAST TRACK ENGINEERING CERTIFICATION Permittee: Steele Creek (1997) Limited Partnership Project: Steele Creek Retail Center WORDS ORESVILLE REGIONAL OFFICE Permit No. WQ0037057 Issue Date: 46/01/14 Cornplete and submit INs form to the permit issuing regional office with the following. • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (GO or DVD disk) in pdf format, Record drawings should Indicate the design and the marked up changes during construction. • Supporting design calculations ('selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications ere required for env chanties resuttlna in non-compliance with tihis. Permit regulations qr minimum design criteria, Modific iQn>E should be eubmittedpri9r to certification. This project shall not be considered comprete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore, It is hlahly recommendeddiet this certification be sent in a manner that Pr1?yides Proof of receipt by the Dlvislgn. PERM ITTEE'3 CERTIFICATION 1, Larry Estridge the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof, Larry Estridge, General Counsel Printed Name, Title Signet R $ CERTIFtCAfl N Krisl*o her ",, Rowe Partial [$� Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe { periodically, 0 weekly, © full time) the construction of the subject project the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 199, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS DIVISION OF WATER RESOURCES WATER QUALITY REGIONAL OPERATIONS SECTION MOORESVILLE REGiCNVAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 M©ORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, 1012348 STEELE CREEK MAJOR INFRASTRUCTURE 1012348 Steele Creek Retail Center Final Sewer Certification For your use Kris Rowe 223 North Graham Stree' Charlotte, NC 28202 NCDENR Division Of Water Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, NC 28115 LandDesign, Inc, ROS 00 VIE REGIONAL AFIRE 40/201 00024 Overnight krovwerlarddesign.corri Enclosed is the final sewer certification for Steele Creek Retail Cent ( 37O o Feel free to contact me if you have any questions, Sincerely, Kris Rowe, PE Steele Creek Retail Center Final SeSewer Certification