Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0036991_Regional Office Historical File Pre 2018
irr NCDENR North Carolina Department of Environment and Natural Resoul=ces Division of Water Resources Water Quality Programs Pat McCrory Thomas A. Reeder Governor Director March 6, 2014 Michael Gribbfe, Development Manager Northwood Ravin 1057 East Morehead St., Suite 300 Charlotte, NC 28204 Subject: Permit No. WQ0036991 Holly Crest Apartments Wastewater Collection System Extension Mecklenburg County Dear Mr. Gribble: John E. Skvarla, Ill Secretary In accordance with your application received on February 28, 2014, we are forwarding herewith to Permit No. WQ0036991, dated March 6, 2014, to the Northwood Ravin for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be responsibility of the Northwood Ravin to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit, This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Mooresville Regional Office Location: 610 East Center Ave., Suite 30'f Maareeville, NC Phone: {704) 663-1699 l Fax: (704) 663-6040 l Customer Internet: www.ncwatergualiy.arg An Equal Opportunity l Affirmative Acfuan Employer 77-623-6748 flee N©rth+Carolina. Naturally Northwood Ravin WQ0036991 If you need additional information concerning this matter, please contact Sujatha Nagulapally at (704) 663-1699 or via e-mail at Sujatha.Nagulapally@ncdenr.gov. for Thomas A. Reeder Division of Water Resources by Michael Parker Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Cc: Mooresville Regional Office Mathew Mobley, P.E., Design Resource Group (e-copy) Water Resources Central Files PERCS NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Northwood Ravin Mecklenburg County for the construction and operation of approximately 1,556 linear feet of 8-inch gravity sewer to serve the Holly Crest Apartments project and the discharge of 54,000 gallons per day of collected domestic/commercial wastewater into the Charlotte Mecklenburg Utilities sewerage system, pursuant to the application received February 28, 2014, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit, This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. Permit issued this 6th day of March, 2014, r Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0036991 SUPPLEMENT TO PERMIT COVER SHEET Northwood Ravin is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the McDowell Creek Wastewater Treatment Facility (NC0036277) prior to being discharged into the receiving stream. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions, I. SPECIAL CONDITIONS If, at any time, the additional wastewater flow volume made tributary to this sewer extension is believed to exceed the value permitted herein, a modification shall be requested for this permit from the Division of Water Resources to properly allocate the subject wastewater flow. No flow in excess of the quantity permitted herein, 54,000 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Water Resources. II. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. Noncompliance Notification: The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number 704 663 -1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300, Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. Per 15A NCAC 2T.0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting pump station design calculations (selected pumps, system curve, operating point, buoyancy calculations, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project. I c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on'the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non- compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. . 8. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 9. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's. Gravity Sewer Design Criteria adopted February, 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and -under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. FAST TRACK ENGINEERING CERTIFICATION Permittee: Northwood Ravin ' Permit No. WQ0036991 Project: Holly Crest Apartments Issue Date: 3/06/2014 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CO or DVD disk) in pdf format Record drawings should indicate the design and the marked up changes during construction, Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting In non-compliance with this permit, regulations or minimum design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineers Certification and all required supporting documentation, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. PERMITTEE'S CERTIFICATION , the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof, Printed Name, Title Signature Date ENGINEER'S CERTIFICATION 0 Partial Li Final ____, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (1U periodically, r weekly, J full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting materials, North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS DIVISION OF WATER RESOURCES WATER QUALITY REGIONAL OPERATIONS SECTION MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions .DWR Use Only: F tow from this project is trifricary to: USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Owner/Permittee: la, Northwood Ravin Full Legal Name (company, municipality, HOA, ut9lity, etc. 1 b. Michael Dribble, Development Manage_ Signing Official Name and Title (Ptease review 15A NCAC 2T 01 The legal entity who will own this system is: El Individual ❑ Federal ❑ Municipality 0 State/County 1d. 1057 East Morehead St.,, Suite 300 Mailing Address NC Application Number: (to be completed by DWR) b 0 Private Partnership ❑ Corporation ❑ Ott le. Charlotte State 704-714-9681 Telephone Facsimile ,. Project (Facility) Information: J a. Holly Crest Apartments O. Brief Project Name (permit will refer to this name Contact Person: Matthew Mobley Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-343-0608 Phone Number New ❑ Modification (of an existing permit) Owner is 0 Public (skip to Item B(3)) ►4 Private 2a, If private, applicant will be: Retaining Ownership (i.e, store, church, single office, etc,) or El Leasing units (lots, townhomes, etc, - skip to item B(3)) ❑ Selling units (lots, townhomes, etc. - go to item B(2b)) Charlotte Mecklenburg Utility Department (CMUD) City g. 28204 Zip Code ibblenorthwood E-mai 2b. Mecklenburg County Where Project is Located 3c. Matthew@drgrp.com E-mail 69'9 I (specify), 2b, If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction D) 0 Homeowner Assoc./Developer (Instruction E) Owner of Wastewater Treatment Facility (VWVrF) Treating Wastewater From This Project 4a. McDowell Creek Waste Water Treatment Plant 4b NC0036i277 Name of WWTF WWFF Permit No. CMUDGravity I5c, WQ0005451 (08-27-91) Owner of Downstream Sewer Receiving Sewer Size ,❑ Force Main iPermit # of Downstream Sewer (Ins The origin of this wastewater is (check all that apply): ❑ Residential Subdivision Apartments/Condominiums ❑ Mobile Home Park ❑ School Q Restaurant Office Retail (Stores„ shopping centers) 0 Institution Hospital ❑ Church ❑ Nursing Home ❑ Other (specify): Volume of wastewater to be allocated or permitted for this particular project: 54,000 'Do not include future flows or previously permitted allocations 100% CtomesticiCommercial Industrial (Attach Description) Other (Attach Description) gallons per day If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA 08-13 APPLICATION Page 4 of 6 0 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 't5A NCAC 2T ,0114 for'. the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use! data in accordance with 15A NCAC 2T .0114 (f). 400 Apartment Units @ 135 Gallons/Day/Unit = 54,000 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 Length (feet) 1,556 New Gravity or Additiona Force Main New Gravity Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID: NA (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow (MGD) Operational Point Power Reliability Option GPM 1 ' permanent generator w/ATS; 2 - portable generator wlMTS Force Main Size Force Main Length Pump Station Location ID: (self chosen - as shown on planslmap for reference) Longitude: Latitude; Design Flow Power Reliability Option Operational Point (MGD) GPM @TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w1MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? [] Yes El No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) Does the sewer system comply with the Minimum Resit n Criteria for the Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? R Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 08-13 APPLICATION Page 5 of() 14. Have the following permits/certifications been submitted or approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 4O1Certification? 0 Yes [] No N/A Sedimentation and Erosion Control Plan? Yes © No El N/A Trout Buffer Waiver? El Yes Q No ® NIA Stormwater? ED Yes © No 111 NIA 15. Does this project include any high pnority lines (15A NCAC Q2T ,0402 (21) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: © and provide details: • Owner/Permittee's Certification (Signature of Signing Official and Project Name) I, ;t ' =Ga, attest that this application for l Ir;i Po v � : has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation iigning Official Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T 0305 Professional Engineer's Certification: (Signatu of Design Engineer and Project Name) ,attest that this application for Holly Crest Apartments has been reviewed by me and is accurate, comptete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-215.6S, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 1, Matthew L. Mobley 2a, Matthew L. Mobley Professional Engineer Name 2b. Design Resource Group, PA Engineering Firm 2c. 2459 Wilkinson Boulevard, Suite 200 Mailing Address 2d, Charlotte ,2e. N28208 City estate Zip 2g, 704,343,0608 2h. 704.3 8,3093 2i. metthewdrgrp com Telephone Facsimile E-mail NC PE Se Signature & Date FTA 08-13 APPLICATION Page 6of6 'rt esource group Date: February 27, 2014 To I CDENR - Division of Water Resources Mooresville Regional Office 10 East Center Ave., Suite 301 Mooresville, NC 28115 From: MattheMatthew L. Mobley, P.F. Re: Northvvood Ravin - Holly Crest Apartrnents Fast -Track Application for +ravityevwer Collection Systems Job : 440 001 Dear Sir/Madam:' Please find' enclosed the Fast Track Application Package fora gravity sanitary sewer extension to serve 400 Units in the Holly Crest Apartments community located in Funtersville, North Carolina, The enclosed submittal package includes the following; Application Form (ETA 08-13) (1 original) Application Form (ETA 8-13) (1 copy) Application Fee (480 Check) Flow Tracking/Acceptance For (FTSE 0-13) Watershed Classification Form (WSAS 8-13) USES Topo Map Street Level Map If any additional ,information is needed to process this request, please feel free to contact me at 704.343.0608 x318. 2454 ilrEi€rs ra bo sl ti rr_1„s charlotte rc 3 > 704-34 €3 ai3 I 04 :3:58-3093 CHAR OTTE. CHARLOTTE-MECKLENBURG UTILITY DEPARTMENT November 7, 2013 Mr, Matthew Mobley Design Resource Group, PA 2459 'Wilkinson Boulevard Suite 200 Charlotte, NC 28208 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE HOLLY CREST PARCEL# 009-272-15, -16 C-MU TRACKING# 600-13-636 A flow acceptance study of the subject site has been completed and it has been deterrnined that: Charlotte -Mecklenburg Utility Department (C-MUD) agrees to accept the gravity sewage flow of 54,000 gallons per day (400 apartment units x 135 gpd/unit) from this project for transmission to the McDowell Creek Wastewater Treatment Plant; NPDES permit number NC00036277, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see attached NCDENR Flow Tracking form, C-MUD agrees to furnish water to the subject project. The water quality to the subject project is regutated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 016001, on file with the Public Water Supply Section of NCDENR, However, C-MUD cannot guarantee a constant pressure or quality of flaw, C-MUD does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing: growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MUD system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the approprfate authorization to construct rmits are not obtained and construction has not started within one (! year of issuance of this flow acceptance; and payment for any service connection(s) have not been received within 1 ear of the is uanc e of this floor ac Lance this flaw acceptance approval shall be rescinded and a new fitow acceptance study must be rinds. if you have any questions, please do not hesitate to contact me at (704) 432-5801, Sincerely, mom, C , „C9r„ ra Gross Engineering Assistant CHARLOTTE-M CKLENBURG UTILITY DEPARTMENT Engineering Division • lnst ion & Development Services t�.ccrtutif ltles.ctrm 7t 0 North Tryon Street Charlotte, NC 28202 Ph: 704/432-5801 Fax: 704/432-5804 Division of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-I3) Project Applicant Name: Design Resource Group, PA -- - Project Name for which flow is being requested: Holly Crest More than one 1 3E may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewaterflow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McDowell Creek WWTP NC0036277 b. WWTP Facility Permit #: c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used Allflaws are in MG» 12.00 0.576 9.79 0.059 5.345 94.5% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Page 1 of 6 FTSE 08-13 III. Certification Statement: I rff S •K ear, v., certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections. I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature Date Page 2 of 6 FTSE 08-13 FORM WSCAS 08-13 ' WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name Project Name Haiiy'Crest Matthew Mobley Professional Engineer Name Engineering Firm Name Matthew Mobley Design Resource Group Location 1D Name of Waterbody County River Basin Waterbody Stream Index No. Waterbody Classification II Unnamed tributary. to Caldwell Station Creek Meck E14-115-2-{1 j C Catawba L I i J L J . I I I___J— = r 1 f 1 I 1 i 1 1 1 1 1_ 1 I _1 - 1 L] 1 1 I I 1_ _1 1 L 1 l I I J 11 I 11 1 i t _ i 1--1 1_ 1 l- J 1 I 1 1 1 1 I 1 I 1 f 1 1 1 1 1 1--1 L_J i J LJ i J 1- 1 1 I 1 I Et unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. 1 certify that as a Registered Professional Engineer in the State of North Carolina that i have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and con-ect to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS 08-13 *** El El 0 0 El 00E/rpor-Jmy r CI ri r [1 CI_ 1 CJ r Cl o El I J t C! >:l nn❑❑ iOi ICI%CI❑A ❑G❑r ❑ ❑ r`� I .` Off'�ry6' L JG I LLD .0 ❑ C� cJ J s❑ I l '` J CI ❑ oRE_GLJr:❑L','�I EALfE7❑f30''❑u._1 ODE ❑ 0 '❑ is r v0342672 % c rJ 0 El l�}30 rJ El EJ••' j El I El ErErEi El 0 0Eli "CI0Cl El 0J1'/1 CI0E o C] Eo." : I r" ❑ CI El IA C: L., -.J LI ❑ El El �j`)3. .0 j NE . • ��' •••• crElr ❑ s7 n L••i _.94. ='I••i�`'�\ ���I n mb rl ❑CiQC10Er]❑L, �'LEvvJLLi E. loOs. 1�E➢0 ❑0 �co❑r'n°cl�' E-10�3.I10 tl i 11111- 7 r` it ;, , }} t FORM: WSCAS 08-13 Page 1 of 1 USGS TOPO CORNELIUS QUADRANGEL NORTH CAROLINA 7.5 MINUTE SERIES design resource group • landscape arch'ite Lure • civil engineering • urban design • land planning • traffic engineering • transportation planning 2a59 wvilkinson boulevard, scur¢e 244 errar1Q , re 20298 704,34/(*2 d 7r7 i.35c,3n93 MNM1VArr 9p,C vfl SCALE NTS PROJECT #. 409-002 DRAWN 94 KK C ECKtp B IAAI USGS MAP ATE.DECEMBER30,2013 REVISIONS: EXHIBIT 1 Copyright a:5 2013 Design Resource Group, PA This plan or drawing and any accompanying documen solely for the use of the recipient noted, No third party use or modification $s permitted h done ate the property of Design Resource Group, PA; and ore intended err authorization, y tcrr tee US• pion or drawing orrd ony occomponyfng locum No third party u or modificotion is permitted with written oath he property of Design design resource group • ▪ landscape ar[hirkctrure civil engineering urban design * lard planning • araftir„ en veer ng • IransportatEon plannlnq 2,59 4,341k,rtsmo }.,cnlatswale, Butt 200 rhartottk, nc 21208 p rt;a 143,0468 f h)4 3S B.3393 43.43330.34334, a bm SCA,E NTS PROIICT 4o9-002 okawN Br (I !CC KED F? J%I STREET MAP ELATE DEGEMBSER 30,2a1.9 REVISIONS EXHIBIT 2 North Carolina Secretary of State Page 1 of 1 Account Login Register North C-arolirr Elaine F Marshall x E °t; `l`HE Secretary SEC RE TARY o S VA FE po Dan.2 ir2r Wei . ht 2752Q-K21 t915:NR-2000 Date: 2/28/2014 Click here to: View Document Filings I File an Annual Report Print a Pre -populated Annual Report Fillable PDF Form I Amend A Previous Annual Report I Corporation Names Name • ; Name Type NC NORTHWOOD RAVIN LLC LEGAL Limited LiabilityCompany Information SOSID: Status: Effective Date: Citizenship: State of Inc.: Duration: Annual Report Status: Registered Agent 1227992 Current -Active 10/31/2011 FOREIGN DE PERPETUAL CURRENT Agent Name: Office Address: Mailing Address: Principal Office! CT CORPORATION SYSTEM 150 FAYETTEVILLE ST., BOX 1011 RALEIGH NC 27601 150 FAYETTEVILLE ST., BOX 1011 RALEIGH NC 27601 Office Address: Mailing Address: Officers/Company Officials 1057 EAST MOREHEAD STREET, SUITE 300 CHARLOTTE NC 28204 1057 EAST MOREHEAD STREET, SUITE 300 CHARLOTTE NC 28204 Title: Name: Business Address: MEMBER RAVIN PARTNERS LLC 1057 E MOREHEAD ST., STE. 300 CHARLOTTE NC 28204 This website is provided to the public as a part of the Secretary of State Knowledge Base (SOSKB) system. Version: 2449 http:I/www.secretary.state.nc.us/corporations/Corp.aspx?PiternId=9857587 2/28/2014 Central Files: APS SWP 3/6/2014 Permit tr ber WQ0036991 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sujatha,nagulapally Coastal SWRule Permitted Flow 5,400 Facility Version Permit Classification 1,00 Individual Permit Contact Affiliation Facility Name Holly Crest Apartments Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Northwood Ravin Dam/Events Owner Type Non -Government Owner Affiliation Michael Gribbie 1057 E Morehead St Charlotte NC 28204 Orig Issue 3/6/2014 Scheduled App Received Draft initiated Issuance Public Notice issue Effective Expiration 3/4/2014 3/6/2014 3/6/2014 Reg Activities Apartment complex Condominium Wastewater collection Oiatfail Requested !Received Events Additional information requested Additional information received Waterbody Name Streamlndex Number Current Class Subbasin Ertel, Debbie From: Childs, Janene Sent: Tuesday, March 04, 2014 4:45 PM To: Ertel, Debbie Subject: Check for Fast Track Applic - Holly Crest Attachments: hppscan478.pdf Importance: High Hi Debbie, Michael Parker asked me to send you a copy of the check for the Holly Crest project to be processed by your office via Fast Track. Please email back the permit number. Once I have this information the RRO will deposit the check into the SWP account. Many thanks, please let me know if you need anything further. Janene Janene S. Childs, Regional Administrative 011icc Manager Raleigh Regional Office Division of Environmental Assistance & Customer Service (DEACS) NC Department of Environment Sr.. Natural Resources 380() Barrett Drive, Raleigh, NC 27609 Phone: ne: 919-7914 205 Fa:919-571-4718 Mailing Address: 1628 Mail Scrvicc Center, Raleigh, NC 27699-1628 "Write it on your heart than every day is the best day in tfie year. " - Rafph 1Vafd"o Emerson Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 1 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES MAR -3 .. 1=2)11N111. Division of Water Resources Raleigh Regional Office Non -Discharge Pump and Haul Permit Application Application Number: (to be completed by DWQ for new projects) I. GENERAL INFORMATION: 1. Applicant (corporation, individual, other): Duke Energy Progress, Inc. 2. Print owners or signing official's name and title (person legally responsible for the facility and its compliance): John D. Daffier- Plant Manager, Harris Plant 3. Mailing address of applicant: 5413 Shearon Harris Road City: New Hill • State: NC Zip: 27562 Telephone number: (919 ) 362-2000 Facsimile number: (919) 362-2322 Email Address: John.Dufner@duke-energy.com 4. Project name (facility or establishment): Harris Nuclear Plant Pump and Haul Permif 5. County where project is located: Wake 6. Fee submitted: $ 1.310.00 (See Instruction B.) 7. Name and complete address of engineering firm: McKim & Creeds Chuck -Riley, Jr. 94n '.Jn....a. n.:,.a C.,:m Knn DUkE ENERGY. 1•rW..•ta-ft" ti..�:+�M+eri 42«:: ...►tDUKB"eNERQ ,NAMVME'•MYLOGr ARKEL 'HOC©• raucrNQC••;roww E !IE34l A Duke Energy' 13usiness Services ;• , 400 Saudi Tryon Street , CGarlolte, NC 28285 Corporate Accounts Payable ST2513 40DSouibItyun Streat. ,^= • ^'=— -tee . JPMORGAN CHASE.BANK, N:A. Syracuse, NY tl ',Aar aAla, 1000112080 50-937213 i''iy' -°' `' One.thousand t/iree hundred ten and.rx / 100 Dollars To The, Order Of NORTH CAROLINA DEPARTMENT OF ENVIROMENT AND NATURAL RESOURCES RALEIGH. REGIONAL OFF 1 6i28 MAIL SERV CTR Raleigh; NC 27699 pate 1/21/I4 S**1,310.00 Authorized Signature RECEIVEft,NcDf NR! VP wr 1 v' r I`I(, f°K; f:iNGf Permitteei Northwood Ravin w Rt Permit Na. WQ003fi991 Project Holly Crest Apartments fCid7,E V la,E RFt ftaNAL OFFI( Issue Datei 3/06/2014 Completra and submit this form to the permit rssetis'rr1 regional office with the following, • One copy of the, project record drawings (plan & prcafiie views and detail drawings of se er `sines) of the wastewater collection system extension Final record drawings should be clear on the plans or on digital rnedia (CD or DVD disk) in pdf ft'.rrrneat. Record drawings should indicate the design and the marked up changes during construction. ■ Supporting design calculations (selected pumps. system curve, operating point, available storage .if portable genoratortls) or storage greater than longest past three year outage reliability option selected) for any pomp stations. permitted as part of this project • Changes to the project should be cle( y ied en the record dr av modifications are required for any changes resulting in nark-c rnit trnumdesign criteria, Modifications shourd be submitted prnar written surrrrrmary taarrn Permit with thispermit, regulatwrt r ion, Tnis project shall not be considered complete nor allowed to operate until the Dr lion tras received this Engineers Certification and ali required supporting documentation. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, PERMITTEE°S CERTIFICATION I, " r ar v I t t:„�:rr �•- the undersigned went or the Permlttee, hereby state that this project has been constructed pursuant to the applicable standards & requirements the Professic nal Engineer below has provided applicable desrgnlconstruction information to the Permittee, and the Permittee is prepared to operate & aarntain the wastewater collection system permitted herein or portions thereof. CERTI ON Partial k) Final duly registered Profess'anal Engineer In the State ,of North Carolina, inavirtg been authorized to rndically, weekl'y,1. full time) the construction or the subject project for the Permittee hereby state that, to tote best of my abilities, due care and diligence was used in the observation of the construction such that the oonstruution was observed to be hurit within substantial compliance of this permit, 15A NCAC 02T. the Division's Gravity Sewer Minimum Design Criteria adopted February 12, f 0c96 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June I, 2000 as applicable, and other supporting materials_ North Caroni Profess Seal, signal e„ and da The Permittee —spa 1 wastewater flow made tributary t. Engineer's Certification shall be con enforcement actions neer's SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUBRED ATTACHMENTS TO THE FOLLOWING ADDRESS DIVISION OF WATER RESOURCES WATER QUALITY REGIONAL OPERATIONS SECTION MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 ng at partial certifications r<p rrrttil a furrai certification is received Any wastewater collection system extension prior to completion of this idered a violation of the permit and shall subject the Permittee to appropriate