Loading...
HomeMy WebLinkAboutNCC204502_NOT Closeout Documents_20211117INSPECTION CARD Town of Southern Pines { \'® BP tm'� PARCEL # PERMIT # TYPE 857214343906 20-3728 New Residential Structure 180 SW Broad Street Southern Pines, North Carolina 28387 (910) 692-4003 www.southernpines.net PROJECT ADDRESS 40 PLANTATION DR SOUTHERN PINES, NC 28387 PROJECT DESCRIPTION new residential construction OWNER ENNISMORE PROPERTIES, LLC PHONE APPLICANT LATITUDE BUILDERS LLC PHONE INSPECTION INSP DATE COMMENT 4 ROUGH -IN Daniel Smith 02/04/2021 PASSED OKto insulate. WATER AND SEWER LINE INSPECTIONS Landon Upchurch 01/25/2021 PASSED Tracer wire in place. TEMP POLE Landon Upchurch 11/03/2020 PASSED FOOTING Landon Upchurch 11/03/2020 PASSED PLUMBING ROUGH -IN Daniel Smith 02/03/2021 FAILED 100psi test is good. Need DWV re -test. Need nail guard for water distribution line coming through sole plate at master bath shower. PLUMBING ROUGH -IN Daniel Smith 02/04/2021 PASSED 100psi and DWV tests are good. Need DWV re -test. FOUNDATION Landon Upchurch 11/23/2020 PASSED PLUMBING FINAL Daniel Smith 07/02/2021 PASSED need additional horizontal support for pvc in crawlspace. PLUMBING FINAL Daniel Smith 06/30/2021 FAILED need additional horizontal support for pvc in crawlspace. FRAMING ROUGH -IN Daniel Smith 02/03/2021 PASSED repair crane holes. Need air barrier between exterior wall and unconditioned space under stairs. Seal around osb in tops of chases next to upstairs shower and tub. FRAMING FINAL Daniel Smith 06/30/2021 PASSED repair Sheetrock in powder room for 3-gang switch location and in master bathroom left of double vanity. Need guardrails on left side of porch or adjust grade to be within 30" 3' away from porch. need silicone around exterior penetrations. hvac pads need to be at least 2" above grade. ELECTRICAL ROUGH -IN Daniel Smith 02/03/2021 PASSED Ground metal boxes as needed. Need fire caulk for Romex going through top plate in master bath. MECHANICAL ROUGH -IN Daniel Smith 02/03/2021 PASSED INSULATION - CEILING Daniel Smith 02/12/2021 PASSED INSULATION - FLOOR Daniel Smith 02/12/2021 PASSED INSULATION -WALLS Daniel Smith 02/12/2021 PASSED R-15 Batts ELECTRICAL FINAL Daniel Smith 07/02/2021 PASSED label outdoor hvac disconnects. garage receptacle needs gfci protection. need additional support for non-metallic cable in crawlspace. MECHANICAL FINAL Daniel Smith 06/30/2021 PASSED BUILDING FINAL Daniel Smith 07/02/2021 PASSED see additional trades / final. BUILDING FINAL Daniel Smith 06/30/2021 FAILED see additional trades / final. GAS ROUGH IN Daniel Smith 02/03/2021 PASSED gas line air test good. TEMP POWER Daniel Smith 06/09/2021 PASSED