HomeMy WebLinkAboutNCC204502_NOT Closeout Documents_20211117INSPECTION CARD
Town of Southern Pines
{
\'® BP tm'�
PARCEL #
PERMIT #
TYPE
857214343906
20-3728
New Residential Structure
180 SW Broad Street
Southern Pines, North
Carolina 28387
(910) 692-4003
www.southernpines.net
PROJECT ADDRESS 40 PLANTATION DR SOUTHERN PINES, NC 28387
PROJECT DESCRIPTION new residential construction
OWNER ENNISMORE PROPERTIES, LLC PHONE
APPLICANT LATITUDE BUILDERS LLC PHONE
INSPECTION
INSP
DATE
COMMENT
4 ROUGH -IN
Daniel Smith
02/04/2021
PASSED OKto insulate.
WATER AND SEWER LINE INSPECTIONS
Landon
Upchurch
01/25/2021
PASSED Tracer wire in place.
TEMP POLE
Landon
Upchurch
11/03/2020
PASSED
FOOTING
Landon
Upchurch
11/03/2020
PASSED
PLUMBING ROUGH -IN
Daniel Smith
02/03/2021
FAILED 100psi test is good. Need DWV re -test. Need nail guard for water
distribution line coming through sole plate at master bath shower.
PLUMBING ROUGH -IN
Daniel Smith
02/04/2021
PASSED 100psi and DWV tests are good. Need DWV re -test.
FOUNDATION
Landon
Upchurch
11/23/2020
PASSED
PLUMBING FINAL
Daniel Smith
07/02/2021
PASSED need additional horizontal support for pvc in crawlspace.
PLUMBING FINAL
Daniel Smith
06/30/2021
FAILED need additional horizontal support for pvc in crawlspace.
FRAMING ROUGH -IN
Daniel Smith
02/03/2021
PASSED repair crane holes. Need air barrier between exterior wall and
unconditioned space under stairs. Seal around osb in tops of chases next to
upstairs shower and tub.
FRAMING FINAL
Daniel Smith
06/30/2021
PASSED repair Sheetrock in powder room for 3-gang switch location and
in master bathroom left of double vanity. Need guardrails on left side of
porch or adjust grade to be within 30" 3' away from porch. need silicone
around exterior penetrations. hvac pads need to be at least 2" above grade.
ELECTRICAL ROUGH -IN
Daniel Smith
02/03/2021
PASSED Ground metal boxes as needed. Need fire caulk for Romex going
through top plate in master bath.
MECHANICAL ROUGH -IN
Daniel Smith
02/03/2021
PASSED
INSULATION - CEILING
Daniel Smith
02/12/2021
PASSED
INSULATION - FLOOR
Daniel Smith
02/12/2021
PASSED
INSULATION -WALLS
Daniel Smith
02/12/2021
PASSED R-15 Batts
ELECTRICAL FINAL
Daniel Smith
07/02/2021
PASSED label outdoor hvac disconnects. garage receptacle needs gfci
protection. need additional support for non-metallic cable in crawlspace.
MECHANICAL FINAL
Daniel Smith
06/30/2021
PASSED
BUILDING FINAL
Daniel Smith
07/02/2021
PASSED see additional trades / final.
BUILDING FINAL
Daniel Smith
06/30/2021
FAILED see additional trades / final.
GAS ROUGH IN
Daniel Smith
02/03/2021
PASSED gas line air test good.
TEMP POWER
Daniel Smith
06/09/2021
PASSED