HomeMy WebLinkAboutSW5210603_Supplement-EZ Form_20211115SUPPLEMENT-L-Z COVER PAGE
FORMS LOADED
PROJECT INFORMATION
Duck Thru at Spring Hope
Project Name _
Project Area ac
4.87
L32 Coastal Wetland Area acSurface
Water Area ac
5
Is this project High or Low Density?
High
6
Does this project use an off -site SCM?
Yes _
COMPLIANCE WITH 02H .1003(4)
7 Width of vegetated setbacks pr
8 Will the vegetated setback rem;
9 If BUA is proposed in the setba
10 Is streambank stabilization proK
(feet) - -- 50
getated? N/A
es it meet NCAC 02H.1003 4 c-d ? N/A
on this protect? No
NUMBER AND TYPE OF SCMS:
Infiltration System
Bioretention Cell
Wet Pond
1
Stormwater Wetland
Permeable Pavement
[20
Sand Filter
Rainwater Harvesting RWH
Green Roof
Level Spreader -Filter StripLS-FS
Disconnected Impervious Surface DIS
21
Treatment Swale
22
Dry Pond
23
StormFilter
24
Silva Cell
25
Bayfilter
Filterra _
26
FORMS LOADED
!DESIGNER CERTIFICATION -s--=-
J. Michael Stocks, PE President
27 Name and Title:
Stocks Engineering, PA
28
Organization:
801 East Washington Street
29
Street address:
City, State, Zip:
Phone numbers :
1 Email:
Nashville, NC 27856
252.459.8196
mstocks@stocksengineering.com
30
31
32
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
�'. `,�N CARD '
Q. ........ �/ 00
: Q' �9 : L
? ? 4 SEAL
00 19843
v Q' aG C2
N No.*GINA*— ob
..oboe
O .100188611100
of Designer
to11z)L1
Date
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
2
3
Does this project have low density areas?
No
4
If so, number of low density drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
2
4
Type of SCM
Wet Pond
Wet Pond
5
Total drainage area (sq ft
218415
189255
11051
6
Onsite drainage area (sq ft
212651
183491
11051
7
Offsite drainage area (sq ft
5764
5764
0
8
Total BUA in project (sq ft
158592 sf
156242 sf
2350 sf
9permitting)
New BUA on subdivided lots (subject to
s ft
158592 sf
156242 sf
2350 sf
10permitting)
New BUA not on subdivided lots (subject to
sf
11
Offsite BUA (sq ft
sf
sf
sf
12
Breakdown of new BUA not on subdivided lots:
- Parking (sq ft
152196 sf
149846 sf
2350 sf
- Sidewalk (sq ft
2196 sf
2196 sf
sf
- Roof (sq ft
4200 sf
4200 sf
sf
- Roadway s ft
- Future (sq ft
- Other, please specify in the comment box
below (sq ft
13
New infiltrating permeable pavement on
subdivided lots (sq ft
14
New infiltrating permeable pavement not on
subdivided lots (sq ft
15permitting)
Existing BUA that will remain (not subject to
s ft
16
Existing BUA that is already permitted (sq ft
17
Existing BUA that will be removed (sq ft
18
Percent BUA
73%
83%
21 %
19
Design storm inches
1.0 in
1.0 in
20
IDesign volume of SCM cu ft
12549 cf
209 cf
21
lCalculation method for design volume
Simple
Simple
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
OFF -SITE SCM
THE DRAINAGE
e o een capaci y o e o si a oW00 c
AREA
1
Drainage area number for this project
2
2
Master permit number
SW5200701
3
Drainage area number from the master permit
4
Lot or outparcel number
1
5
1 BUA allocated by Master Permit
2350 sf
INFORMATION
ABOUT THE OFF -SITE SCM
6
Type of off -site SCM
Wet Pond
7
Available treatment capacity in the off -site SCM (cu ft)
6474 cf
8
Have deed restrictions limiting the BUA on the site been recorded?
No
9
Has an Engineer's Certification for the off -site SCM been submitted to DEQ?
Yes
10
Are there any Notices of Violation for the off -site system?
No
11
Has the off -site SCM been maintained in accordance with its O&M Plan?
Yes
12
Will the collections stem be maintained in its design state and ke t clean?
Yes
ADDITIONAL
INFORMATION
13
1 Please use this space to provide any additional information about the off -site SCM(s):
Th t t
1 t t t 't f th ff 't SCM f SW5200701; 19 076 f C t1 th t d f
r is , . urren y, e we pon o a ra mr
SW5200701 has been permitted to treat 12,602 cf. Therefore, the available treatment capacity is 6,474 cf.
WET POND
ERAL MDC FROM 02H .3050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM H:V ?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC 9 ?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
16
Does the SCM follow the device specific MDC?
Yes
17
Was the SCM designed by an NC licensedprofessional?
I Yes
WET POND
MDC FROM 02H .1053
18
Sizing method used
SA/DA
19
Has a stage/storage table been provided in the calculations?
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl)
251.00
21
Elevation of the main pool bottom (top of sediment removal) (fmsl)
252.00
221
Elevation of the bottom of the vegetated shelf fmsl
259.00
23
Elevation of the permanent pool (fmsl)
260.00
24
Elevation of the top of the vegetated shelf fmsl
260.00
25
Elevation of the temporary pool (fmsl)
261.43
26
Surface area of the main permanent pool square feet
5762
27
Volume of the main permanent pool (cubic feet)
19092 cf
28
Average depth of the main pool feet
3.00 ft
29
Average depth equation used
Equation 2
30
If usingequation 3, main pool perimeter feet
31
If using equation 3, width of submerged veg. shelf (feet)
32
Volume of the foreba cubic feet
3157 cf
33
Is this 15-20% of the volume in the main pool?
Yes
34
Clean -out depth for foreba inches
48 in
35
Design volume of SCM (cu ft)
31063 cf
361
Is the outlet an orifice or a weir?
Orifice
37
If orifice, orifice diameter (inches)
2 in
38
If weir, weir height inches
39
If weir, weir length (inches)
40
Drawdown time for the temporary pool (days)
2.4
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
42
Are berms or baffles provided to improve the flow path?
No
43
Depth of forebay at entrance inches
255 in
44
Depth of forebay at exit (inches)
259 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
46
Width of the vegetated shelf (feet)
6 ft
47
Slope of vegetated shelf H:V
6:1
48
Does the orifice drawdown from below the top surface of the
permanent pool?
Yes
49
Does the pond minimize impacts to the receiving channel from the 1-
yr, 24-hr storm?
Yes
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.)
No
Is a trash rack or other device provided to protect the outlet system?
Yes
L
Are the dam and embankment planted in non -clumping turf grass?
Yes
Species of turf that will be used on the dam and embankment
Centipede
Hasa planting plan been provided for the vegetated shelf?
Yes
ADDITIONAL INFORMATION
55
Please use this space to provide any additional information about the
wet pond(s):
Should the 5,764 sf of offsite drainage area become built upon The Duck Thru Pond
has an additional 18,514 cf of storage available to treat the increase in impervious
area.
Wet Pond 4 10:55 AM 1111112021