Loading...
HomeMy WebLinkAboutNCG030666_2021 DMR_20211101NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG030666 Person Collecting Samples: Adrianne Brookshire Facility Name: US Chemical Storage - Plant 1 Laboratory Name: Pace Analytical Facility County: Wilkes Laboratory Cert. No.:12 Discharge during this period: Yes No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes No If so, which Tier (I, II, or III)? Tier II A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.goy/Forms/SW-DMR Byes U No Date Uploaded: 11/1/2021 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class Yadkin N/A Date Sample Collected MM/DD/YYYY 10/7/2021 46529 24-Hour Rainfall in inches 1.25 C0530 TSS in mg/L (100 or 50*) ND 00400 pH in standard units (6.0 — 9.0 FW, 6.6 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) ND Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) ND Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.13 00340 Chemical Oxygen Demand (COD) in ND mg/L (120) 00552 Non -Polar Oil & Grease in mg/L (15) * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): Response to sample 9/21/2021, Zinc level came down from 0.20 to 0.13 "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false,,information, including the possibility of fines and imprisonment for knowing violations." L4al lGill , )U1GtA"&S(A'" 11/1/2021 Signature of Permittee or Delegated Authorized Individual Date abrookshire@uschemicalstorage.com Email Address 336-990-0912 Phone Number