Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0034432_Regional Office Historical File Pre 2018
4 A VA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary November 3, 2009 Mr. Dee -Dee Harris, President CMH-DWH Ballantyne, LLC 6400 Fairview Road Charlotte, NC 28210 Subject: Permit No. WQ0034432 Providence Road West Walgreens Tax Parcel #223-134-85, 97 C-MU Tracking # 600-08-673 Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Harris: In accordance with your complete application received on October 30, 2009, we are forwarding herewith Permit No. WQ0034432, dated November 3, 2009, to CMH-DWH Ballantyne, LLC, for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3, which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-205.6A through §143-205.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 1 Fax: (704) 663-60401 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer— 50% Recycled/10% Post Consumer paper No�rthCarohna Natural!!! Mr. Dee -Dee Harr Page 2 November 3, 2009 In accordance with the provisions of Article 20 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 110 linear feet of 4-inch gravity sewer and 970 linear feet of 8-inch gravity sewer and the discharge of 1,748 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the McAlpine Creek VWVTP (NPDES No, NC0024970) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system is the complete responsibility of Charlotte Mecklenburg Utilities, Charlotte Mecklenburg Utilities must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the VVQCS00001 permit requirements. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Michael Parker at (704) 663-1699 Electronic copies. Cc: Sincerely, for Co een H. Sullins Meredith Moore, Mecklenburg County Development of Water Quality Barbara Gross, CMU Philip Edwards, Mecklenburg County Kristopher W. Rowe, P.E , LandDesign, Inc. Mooresville Regional Office, Collection System Permit File Surface Water Protection Central Files PERCS • NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-205.1C. 4 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T ,0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 205.6A through §143-205.6C. In the event that the wastewater collection facilities fall to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B ,0200 and 15A NCAC 2H .0500, 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Arty failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 3rd day of November, 2009. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0034432 Permit No. WQ0034432 June 10, 2009 Owner/WQCS Dee -Dee Harris 6400 Fairview Road Charlotte, NC 28210 PE Kris Rowe, P. E, LandDesign, Inc. 223 North Graham Street Charlotte, NC 28202 WQCSI WWTP Barbara Gross CMU 5100 Brookshire Blvd Charlotte, NC 28206 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are re uired for any than es resultin in non-com Hance with this ermit requlations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division° ENGINEER'S CERTIFICATION D Partial ] Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Providence Road West Walgreens, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T„ the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal,, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 4 OF NORThf CAROLINA. COUNTV'OF MECKLENBURG Permit No, DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this 29th day of October 2009 , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and a corporation/general partnership registeredflicensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: CMH-DWH BALLANT'YNE, LLC l . The DEVELOPER is the owner of the certain lands lying in MECKLENBURG.rmm. County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known ROAD WEST WALGR ENS as (hereinafter the Development). PROVIDENCE The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to aS. 143- 215.1 to construct, maintain, and operate the Disposal System. 4, The DEVELOPER has created or shall create unit ownership in said dwellings units., other improvements and lands through fling of a. Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the Providence Road Retail Associati«r (hereinafte'r Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal. System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each c fthe parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and. specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. The DEVELOPER shall not transfer ownership and'or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. The DEVELOPER shall not. transfer, convey, assign or otherwise relinquish or release its respon for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. sibility FORM: DEV 02/03 Page 1 of The DEVELOPER shall provide in the. Declaration and Association Bylaws that the Disposal. System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and ' operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses.. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal. System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and. shall be part of the yearly budget. ti. in the event the common expense: allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shal➢ provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment andlor disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall h.ereinafier become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental. system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the AssociationBylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a. permit. The agreements set forth in numbered. paragraphs 1, 2, 3, 4,. 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. lt). A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the 'Declaration is filed and in the offices of the Secretary of State ol'North Carolina with the Articles of Incorporation of the Association. IN WITNESS WI~IER.EOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL MA GEMENT COMMISSION Co ccn H. Sullins, Director Division of Water Quality (Date) CMH-DWH BALLANTYNE, Name of DEVELOPER By: (Signature) DEE-DEE HARRIS, PRESIDENT Print. Name and Title o a? o (Date) FORM: DEV Page 2 o USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner/Permittee: 1 a. CMH-DWH Ballantyne, LLC Full Legal Name (company, municipality, HOA, utility, etc.) 1b. Dee -Dee Harris - President Application Number: (to be completed by DWQ �41 Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing official The legal entity who will own this system is: ❑ Individual El Federal ❑ Municipality ❑ State/County ❑ Private Partnership 1 • 1d. 6400 Fairview Road LL Mailing Address • 1f. North Carolina State Q 1 h. 704-364-4957 Telephone Project (Facility) Information: 2a. Providence Road West Walgreens 1 i. 704-364-5014 Facsimile Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Kris Rowe — LandDesign, Inc 1 e. Charlotte Corporation ❑ Other (specify): City lg. 28210 Zip Code cmoonha rrisland.com1! E-mail 2b. Mecklenburg County Where Project is Located `. Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, 704-376-7777 Phone Number 1. Project is 1 New ❑ Modification 0 3c. kroweClanddesign,com E-mail an existing permit) If Modification, Permit No.: 2. Owner is ❑ Public (skip to Item 8(3)) 2a. If private, applicant will be: Retaining Ownership (i.e. store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to Item B(3)) Selling units (lots, townhomes, etc. - go to item B(2b)) 3. Charlotte Mecklenburg Utilities ® Private go to Item 2(a)) 2b. If sold, facilities owned by a (must choose one ❑ Public Utility (Instruction C) Homeowner Assoc./Developer (Instruction D) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. McAlpine Creek Treatment Plant Name of WWTF 5a. Charlotte Mecklenburg Util, 5b. 8"' 4b_ NC0024970 Gravity 5c. Owner of Downstream Sewer Receiving Sewer Size !El Force Main 6. The origin of this wastewater is (check al Residential Subdivision El Apartments/Condominiums Mobile Horne Park ❑ School El Restaurant ❑ Office that apply): WWTF Permit No, Permit # of Downstream Sewer (Instru ® Retail (Stores, shopping centers) 0 Institution ❑ Hospital Church ❑ Nursing Home ❑ Other (specify): 100 % Domestic/Commercial Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify): 7, Volume of wastewater to be allocated or permitted for this particular project: 1,748 gallons per day *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: El Pump Station, Outtall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA 12/07 r.Providethe wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for liFiv- the Value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 120 gpd / 1,000 sf of retail. Building is 14,570 sf. 100 * (14,570 / 1000) = 1,748 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 8" 970 Gravity 4" 110 Gravity G 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) W M Pump Station Location ID (self chosen - as shown on plans/map for reference) Z Z 0 Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator w/MTS Force Main Size Force Main Length V B. PERMIT INFORMATION Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator w/MTS Force Main Size Force Main Length Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point GPM @TDH1 Power Reliability Option - permanent generator w/ATS; 2,- portable generator w/MTS Force Main Size Force Main Length 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? 0 Yes ® No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) . 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07 e the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? 0 Yes fl No N/A Sedimentation and Erosion Control Plan? El Yes 0 No Li N/A Stormwater? Yes El No 0 N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T ,0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: 0 and provide details 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Narne) I, Dee -Dee Harris, attest that this application for Providence Road West Walgreens has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 1a. * Signing Official Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMIT`r TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 0 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Kristopher Rowe, attest that this application for Providence Road West Walgreens has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Kristopher W. Rowe Professional Engineer Name 2b, LandDesign, Inc Engineering Firm 2c. 223 N. Graham St Mailing Address 2d, Charlotte 2e, NC 2f, 28202 City State Zip ' 2g. 704.376.7777 2h, 704.332.3246 2i. krowe@landdesign.com Telephone Facsimile E-mail NC PE Seal, Signature & Date HER 1' Moo"' it° FTAI 2/07 CHARLOTTE-M E CKL EN BU RG UTILITIES October 30, 2008 Mr. Matt McLaren LandDesign, Inc, 223 N Graham Street Charlotte, NC 28202 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE PROVIDENCE ROAD WEST RETAIL CENTER TAX PARCEL# 223-134-85, 97 C-MU TRACKING #600-08-673 In response to your request, a flow acceptance study of the subject site has been completed and the following has been determined: Charlotte -Mecklenburg Utilities agrees to accept the gravity sewage flow of 13,669 gallons per day (105,148 ft2 retail with food service x 130 gpd11,000 ft2) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see attached basin map and flow tracking form. Charlotte -Mecklenburg Utilities agrees to furnish water to the subject project, The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, dated October 2005, (WSMP # 05-01702 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR. However, Charlotte -Mecklenburg Utilities cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg Utilities system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. /f the appropriate authorization to Construct permits are not obtained and construction has not stared within one (1) vear of issuance of this flow acce tan a this flow acce Lance a royal shall be rescinded and a new flow acceptance fetl est rrrust be made, If you have any questions, you may contact me at (704) 391-5129. Barbara Gross Engineering Assistant New Services Section CHARLOTTE-MECKLENBURG UTILITIES Customer Service Division • New Services Section www.crnutillties.corn 00 Brookshire Boulevard Charlotte, INC 28216 Ph: 704/399-2221 Fax: 704/393-2219 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE 10/07) Project Applicant Name: andDesign, Inc. Project Name for which flow is being requested: Providence Road West Retail Center More than one FTSE-10/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek WWTP b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 All flows are in MGD c. WWTP facility's permitted flow 99.0 d. Estimated obligated flow not yet tributary to the WWTP 14.83 e. WWTP facility's actual avg. flow 66.8 f. Total flow for this specific request 0.013669 g. Total actual and obligated flows to the facility 81.69 h. Percent of permitted flow used II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD 111. 'on Statempt. 5 kcal , certify that, to the best of my knowledge, the addition of the volume of tewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form indicates acc tance of astewater flow, Signing Official Signature Date Weddi can, NC --- SC Quadrangle 5080-A7-TF-024 Revised 1988 Street Level Map Showing Approximate Connection to Existing Sewer Line pplIV Permit Number WQ0034432 Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer michael.parker Coastal SW Rule Permitted Flow 1748 Facility Facility Name Providence Road West Walgreens Location Address Owner Central Files: APS. SWP_ 11/03/09 Permit Tracking Slip Status Active Project Type New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation MajorlMinor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Cmh-Dwh Ballanytne LLC Dates/Events Orig Issue 11/03/09 App Received 10/30/09 Regulated Activities Retail Wastewater collection Outfall NULL Draft Initiated Scheduled Issuance Owner Type Non -Government Owner Affiliation Dee -Dee Harris 6400 Fairview Rd Charlotte Public Notice Issue 11/03/09 Requested/Received Events Additional information received Additional information requested NC 28210 Effective Expiration 11/03/09 Waterbody Name Stream Index Number Current Class Subbasin Page 1 of 1 TRANSMITTAL 223 North Graham Street, Charlotte, NC 28202 V: 704.333.0325 F: 704.332.3246 DATE: 10/29/2009 PROJECT NAME: 1008092 PROVIDENCE WEST RETAIL CENTER TO: DWQ - Mooresville 610 E. Center Avenue Mooresville, NC 28115 dwgmooresville@dwg.com FROM: CC: Kris Rowe LandDesign, Inc. 223 North Graham Street Charlotte, NC 28202 krowe @ landdesign,corn PROJECT 4: 1t?08092 WE ARE SENDING: Providence Road West `v4°algreens VIA: Overnight PURPOSE: For your review and comment Quantity Dated Description Copies of Application Form $480.00 Application Fee (##3570) Copies of Operational Agreements 1 NOTES: Copy of Charlotte -Mecklenburg Utilities Flow Acceptance Color Map it #tds tlacemmeerti was deiii seed via FAX, the accompanying transmission curtains confidential Mama.. kilanded stay for the use at the individual of the entity named above. tt you are not the intender) recipient you are hereby notified that eery ducks epre, copying, d ateibiAon or the Weing of any action in reliance pre the contents of F A facsimile iniedmXIion tls sleety prohibiited_ if pop have received this FAX tlt 6Troe', please isernea a leie statist` us by telephone to arrange ter disc, sAon or return of the dect+nleflde flo us. Charlotte NC Washington DC Tampa FL Asheville NC Pinehurst NC Charlotte NC Nashville TN Beijing PRC about:blank 10/29/2009 LandDesign. urban design planning civil engineering branding landscape architecture DATE: September 25, 2009 PROJECT NAME: Providence Road West Walgreens TO: NCDENR FROM: LandDesign, Inc RE: Private Sewer Fast Track Project Narrative PROJECT #: 1008092 This project will consist of the construction of a private sewer main to serve a retail building of approximately 14,570 SF. The project will tie to an existing public CMUD line. Future phases of development will tie to this private trunk line. Currently, flow is being permitted for the first building only, but the flow acceptance includes the projected flows for the entire development (+1- 105,000 SF). As additional buildings and connections are permitted, additional flow will be added. PO Box 36959 Charlotte, NC 28236-6959 223 North Graham Street Charlotte. NC 28202 V: 704.333.0325 F: 704.376.8235 FILE PATH: N:1_20081100809210ocs1Permit Forms1NCDENR Private Utiiities\Sewer Project Narritive.doc North Carolina Secretary of State Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE PO Box 29622 Raleigh, NO 27626-0622 (919)807-2000 CORPORATIONS Corporations Home Search By Corporate Name Search For New & Dissolved Search By Registered Agent Important Notice Resale of Tickets Online Corporations FAQ Homeowners' Association FAQ Tobacco Manufacturers Unincorporated Non -Profits Dissolution Reports • Non -Profit Reports Verify Certification Online Annual Reports LINKS & LEGISLATION KBBE B2B Annual Reports SOSID Number Correction 2001 Bill Summaries 1999 Senate Bills Annual Reports 1997 Corporations 1997 Professional Corporations NCSOS Authority to Dissolve Register for E-Procurement, Dept. of Revenue ONLINE ORDERS Start An Order New Payment Procedures CONTACT US Corporations Division TOOLS Secretary of State Home Secretary of State Site Map Printable Page Date: 11/2/2009 Click here to: View Document Filings I Sign Up for E-Notifications I MPrint apre-populated Annual Report Form I Annual Report Count I File an Annual Report 1 Corporation Names Name NC CMH-DWH BALLANTYNE, LLC NC CMH BALLANTYNE, LLC Limited Liability Company Name Type Legal Prev Legal Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent 0366663 Current -Active 3/30/1995 Domestic NC DEC 2030 Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: Swindell, Gary W 227 West Trade Street, Ste 2030 Charlotte NC 28202 227 West Trade Street, Ste 2030 Charlotte NC 28202 6400 Fairview Road Charlotte NC 28210 6400 Fairview Rd Charlotte NC 28210 http://www.secretary.state.nc.us/corporations/Corp.aspx?PitemId=4763388 11/2/2009 Permit No, W©0034432 June 10, 2009 Owner/WOCS PE Dee -Dee Harris Kris Rowe, RE. 6400 Fairview Road LandDesign, Inc. Charlotte, NC 28210 223 North Graham Street Charlotte, NC 28202 WQCSJWWTP Barbara Gross CMU 5100 Brookshire Blvd Charlotte, NC 28206 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until thus Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION L, Partial Final I, Kristopher W. Rowe , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, 0 weekly, El full time) the construction of Providence Road West Walgreens, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track, Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 4 Page 1. of 1. n design planning civil engineering branding landscape architecture TRANSMITTAL 223 North Graham Street, Charlotte, NC 28202 V: 704.333,0325 F: 704,332.3246 DATE: 9/21/2010 PROJECT NAME: 1008092 PROVIDENCE WEST RETAIL CENTER TO: DWQ - Mooresville Regional Office Surface Water Protection 610 East Center Avenue, Suite 3,31 Mooresville, NC 28115 none1@none .corn FROM: CC: Kris Rowe LandDesign, Inc, 223 North Graham Street Chadotte, NC 28202 krowe@landdesign,com PROJECT #: 1008092 RECEIVED DIVISION OF WATER QUALITY SEP 2 3 2010 SWP SECTION MOORESVILLE 1EGONAL OFFICE WE ARE SENDING: Final Sewor Certiflcation VIA: Mail PURPOSE: For your use and distribution Quantity Dated Description 1 Engineer's Certification 1 Set of Field Testing Reports 1 NO : Set of Sanitary Sewer As-Builts if lies AYAXAMOIX VMS OXYXACIXIw E.X. the otterneemetog tranenession coptitientee tefoonation .0,174,d orey for the flee .0 the indendluel of tee emely mooed above, 41' yeel ere .no.4 tee attended movere, ream eeteby reeefied GAYA arty dieeloauft, wfrein9., testaibteeen e, the Itakiel dr any aeben. eelemee eie ...les &this fweekenee ekemeekee meaty prOAXNAYA UyOU ArryA XXXX,Ati ees FAX 414 ewe. Own., eemeehaUey e.tey es by Member. lo sosenge fee emee.eien .eumof the dee...et to tkv. Charlotte NC Washington DC Tampa FL Asheville NC Pinehurst NC Charlotte NC Nashville TN Beijing PRC about:blank 9/21/2010 P/11117arndDesign. urban design planning civil engineering landscape architecture FIELD REPORT Project: Fifth Third Bank Weather: Clear 90° Location: Providence Road and Johnston Road Present Ray Graham, LandDesign at Site: Dean Winesett, C.S Clark David Glover Pioneer Utilities Date: Wednesday August 11, 2010 LandDesign PN: 1008367 Contractor: Cloningers Inc. Pioneer Utilities and Plumbing Total 8 hours Time: CC: Kris Rowe Comments: The waterline for the bank site was tested today. Both the domestic water and the fire lines were tested at 200PSI for two hours. There was no loss of pressure during the test period and the lines were deemed to be acceptable for the pressure test. I informed the contractor that the chlorination test still needs to be performed. After the lines are chlorinated, sampled, and tested the test results will have to be received in our office prior to certification. The sanitary sewer lines were also tested today. Each segment was tested for five minutes under four pounds of pressure. All of the runs passed the pressure test. No vacuum or exfiltration test was performed on the manholes. The contractor was informed that this test would be required prior to certification. Other activities on the site this date was the hauling of stockpiled material and backfilling the retention pond to its final size. The backfill was being tested by S&ME. There was some discussion about the material being used. There was some contaminated dirt with root vegetation that was rejected by S&ME. The contractor removed and replaced this material. NOTE: The work on the slope for erosion purposes has not begun. I also reviewed the erosion control devices and found everything to be acceptable. Signed: **See attached pictures. -1•10'4".? Ray Graham LandDesign, Inc. PO Box 36959 Charlotte, NC 28236-6959 223 North Graham Street Charlotte, NC 28202 V:704.333.0325 F: 704.376.8235 14' ) C1 10'7',t76'"rnraiLchor, ,M1Cm:r f,e;tl R pnir�701P.; .,IL '�$ 14 -nccld Re,10,1 G3 11 1G.4n, Images Image # 1 Placing fill Image # 2 Loading from stockpile P© Box 36959 Charlotte, NC 28236.6959 223 North Graham Street Charlotte, NC 28202 V: 704333.0325 F 704,376,6235 Image # 3 Compacted fill Image # 4 Compacting fill material PO Oox 36959 Charlotte. NC 28236-6959 223 North Graham Street Charlotte, NC 28202 V: 704,3310325 F: 704.376.8235 urban design plan civil enr Lrc. Image # 5 Excavating material from stockpile PO Box 36959 Charlotte, NC 28236-6959 '223 North Graham Street Charlotte, NC 28202 V: 704,333,0325 F:704.376.8235 LandDesign.. urban design planning civil engineering landscape architecture FIELD REPORT Project: Fifth Third Bank Weather: Clear 89° Location: Providence Road and Johnston Road Present Ray Graham, LandDesign at Site: Dean Winesett, C.S Clark Don Johnson, Pioneer Utilities Date: Thursday September 9, 2010 LandDesign PN: 1008367 Contractor: Pioneer Utilities Total 8 hours Time: CC: Kris Rowe Comments: Pioneer Utilities: The contractor is performing vacuum testing of the manholes and deflection test of the sewer lines today. Vacuum test were performed on sanitary sewer manholes #8 and #9. Tests were performed at 10 in of mercury for 2 minutes. Both tests were successful after seams between the sections of manholes were grouted with non -shrink grout. The mandrel for deflection test was performed between manholes; 9&7, 8&7, 7&6, 6&5, 5&4, 4&3, 3&2, and 2&1. All lines were clear and the tests were accepted. Signed: **See attached pictures. Ray Graham LandDesign, Inc. PO Box 36959 Charlotte, NC 28236-6959 223 North Graham Street Charlotte, NC 28202 V:704.333.0325 F: 704,376,8235 N :COn IX8367,Cordn.-tior Adm'r,Fi Reportv 2C ICri CIO Oi iSeptl Fisld Repert 01.09 10 dor ,. rci ;iP E,':t tune mages Image # 1 Vacuum testing Image # 2 Vacuum tester P© Sox 36959 Charlotte, NC 28236.6959 223 North Graham Street Charlotte, NC 28202 V7 204.333,0325 P, 704.376,8235 Image # 3 Gauge on apparatus Image 4 Seating apparatus to manhole PO Box 36959 Charlotte, NC 28236.6959 223 North Graham Street Charlotte. NC 28202 V: 704.333.032S F:704,376.8235