Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0033752_Regional Office Historical File Pre 2018
NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue, Governor Dee Freeman, Secretary January 20, 2009 Mr. Tony Amsaldo Charlotte -Mecklenburg Schools 3301 Stafford Drive Suite 1300 Charlotte, NC 28285 Subject: Permit No. WQ0033752 South Mecklenburg High School Building '0' Tax Parcel #207-211-33 C-MU Tracking # 600-08-678 Wastewater Collection System Extension Mecklenburg County, North Carolina .Dear Mr. Amsaldo: In accordance with your complete application received on January 15, 2009 we are forwarding herewith Permit No. WQ0033752, dated January 20, 2009, to South Mecklenburg High School Building '0' for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3, which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 610 East Center Avenue, Suite 301, Mooresville, North Carolina 28115 Phone: 704-663-1699 \ FAX: 704-663-60401 Internet: www.enr.state.nc.us An Equal Opportunity 1 Affirmative Action Employer - 50 % Recycled 110 % Post Consumer Paper NorthCarolina Naturally. Mr. Tony Amsaldo Page 2 January 20, 2009 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 418 linear feet of 8-inch gravity sewer and the discharge of 15,000 gallons per day ofcollected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the McAlpine Creek WWTP (NPDES No. NC0024970) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system is the complete responsibility of Charlotte Mecklenburg Utilities. Charlotte Mecklenburg Utilities must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WQCS00001 permit requirements. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Michael Parker at (704) 663-1699. Electronic copies: Cc: Sincerely, or oleen H. Sullins Meredith Moore, Mecklenburg County Development of Water Quality Barbara Gross, CMU Philip Edwards, Mecklenburg County Charles J. Cook, P.E., Mooresville Regional Office, Collection System Permit File Surface Water Protection Central Files PERCS v NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 26 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 I 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A .copy of the construction drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. -The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or 2 b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. • Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 20th day of January, 2009. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033752 3 Permit No. WQ0033752 January 20, 2009 OwnerIWQCS Tony Amsaldo 3301 Stafford Drive Charlotte, NC 28285 PE Charles J. Cook, P.E. Little Diversified Architectural Con. 5815 Westpark Drive Charlotte, NC 28217 WQCS/WWTP Barbara Gross CMU 5100 Brookshire Blvd Charlotte, NC 28216 .. Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ['full time) the construction of South Mecklenburg High School Building 'O', a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of -Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 4 USE THE TAB KEY TO MOVE FROM FIE 1, Owner/Permittee: Charlotte -Mecklenburg Schools 1 a. Chariote- �. Full Legal Name (company, municipality, HOA, utility, etc.) 05A .Q ) Signing Official Name and Title (Please review 15A NCAC 2T ,010 1 b. Application Number: (to + completed by DWQ) b) for authorized signing officials!) The legal entity who will own this system is ❑ Individual Dj Federal ❑ Municipality ❑ State/County ❑ Private Partnership 0 Corporation ❑ Other (specify): © ld. 3301 Stafford Drive LL. z 0 Mailing Address 1 f. North Carolina State 1h, CeCcjt Telephone le, Charlotte City 1 g. 2820 Zip Code 'Ca - 343 —C.,0 4] 1j h a F -4---. 145. ' ^c:) Grit.`;, 4c Facsimile E-mail • u'� 2. Project (Facility) information: 2a. ,South Mecklenburg High School Building'0' Brief Project Name (permit will refer to this name 3. Contact Person: 3a, Charles J, Cook, RE, _ Name and Affiliation of Someone Who Can Answer Questions .About this Application 2b. Mecklenburg a County Where Project is Located 3b. (704) 561-7417 Phone Number 1. Project is New ❑ Modification of an existing permit 2. Owner is Public (skip to item B(3)) 2a. If private, applicant will be.. 0 Private 3c. chcook@littleonllne.com E mail edification, Permit No.: go to Item 2(a)) 2b. If sold, facilities owned by a (must choose one) ❑ Retaining Ownership (i.e, store, church, single office, etc.) or ❑ Leasing units (lots, lownhomes, etc. - skip to Item B(3)) • Selling units (lots, townhomes, etc. - go to Item B(2b)) Charlotte -Mecklenburg Utilities Owner of Wastewater Treatment Facility 4a. McAlpine Creek WWTP ▪ Name of WWTF M 5a, Charlotte Meck, Schools5b 8-inch } Gravity ,5c CC Owner of Downstream Sewer Receiving Sewer Size fl Force Main 0 Public Utility (Instruction C) El Homeowner Assoc./Developer (instruction D) ater From This Project 0 a The origin of this wastewater is (check all that apply): LL. Z ❑ Residential Subdivision ❑ Apartments/Condominiums Mobile Home Park ® School ❑ Restaurant El Office 4b. NC0024970 WWTF Permit No. Permi (] Retail (Stores, shopping centers) ❑ Institution ❑ Hospital 0 Church Nursing Home Ei Other (specify): 7, Volume of wastewater to be allocated or permitted for this particular project: *Do not Include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: Downstream Sewer (instruction E 100 % Domestic/Commercial % Industrial (attach description) (RO. contact your Regional Office Pretreatment staff) % Other (specify): gallons per day El Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line Flow has already been allocated in Permit No. Line was installed prior to permitting requirement. See attached CMUD Lever Sheet ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T ,0303 to determine if a permit is required) FFA 12/t)7 19. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item 8(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 1,500 Students X 10 gpd/Student = 15,000 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) ' Size (Inches) Length (feet) New Gravity or Additional Force Main 8 418 New Gravity 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID Design Flow Operational Point Power Reliability Option (MGD) f GPM @TDH i 1 - permanent generator w/ATS; , 2 - portable generator w/MTS - - I- - - (self chosen - as shown on plans/map for reference) Force Main Size Force Main Length O h - QPump Station Location ID r (self chosen -las shown on plans/map for reference) •a Design Flow Power Reliability Option Operational Point O I (MGD) GPM @TDH 1 - permanent generator w/ATS; ; Force Main Size Force Main Length 2 - portable generator w/MTS i i.I. i - - -- - } --L - - ?i1 1 H 2 cc a m Pump Station Location ID (self chosen - as shown on plans/map for reference) r- -- -- - - - -- ---T �_-. - - --- Design Flow I Power Reliability Option (MGD) Operational Pointi 1 - permanent generator w/ATS; I Force Main Size Force Main Length GPM @TDH 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2nd treatment facility (RO - if `yes" to 8,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance Is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07 Pr14. Have the foliowing permitslcertifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings General Permit or 4©1Certification? ©Yes ©No N/A Sedimentation and Erosion Control Plan? sw Yes El No 0 N/A ❑ Yes EJ No N/A. Stormwater? 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: © and provide details 1 a. }uvner/Permittee's Certificatla n: Signeture of Signing Official and Project Name) 1, V44.4 attest that this application for South Mecklenburg High School Building 'Q' has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being return as incomplete, Note: In accordance with North Carolina General Statutes 143-215.6A and 143-216.6B, on who knowingly makes any false .statement, representation, or certification in any application shallb u" y of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil pep to $ is ; violation. Signing © f#icial Sig Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMI I I AL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY' co TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Z 0 2, Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Gharle4 .J. Cook, P.F. _, attest that this application for South Mecklenburg High School Building :t' has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria. for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B,, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 2a. Cheri es.J. Cook, P.E. Professional Engineer Name 2b. Little Diversified Architectural Consulting Engineering Firm 2c. 5815 Westpark Drive Mailing Address 2d. Charlotte 2e, N.C, 2f. 28217 City State Zip 2g. (704) 561-7417 2h. 704 561 8700 2i, chcook@littleonline.com Telephone E-mail NC PE Seal, Signature & Date F'1AI2107 From: Little Diversified Architecture 5815 Westpark Drive Charlotte, NC 28217 To: NCDENR 610 East Center Avenue Mooresville, NC 28115 Cons rng WE ARE SENDING YOU: o Shop Drawings 0 Copy of Letter Copies Date ► Attached ❑ Prints ❑ Change Order Number Attention: TT LE c©rvaa,axPNO Letter of Transmittal outh Mecklenbur• f i«,h School Building '0' ._ Fast Track Sewer A ralication ❑ Under separate cover via the following items: ❑ Samples ❑ Specifications Other Descrip Flow Acce Lance Letter Flow Tracking Form CMU Cover Sheet (1/2 size) Color USGS Map THESE ARE TRANSMITTED AS CHECKED BELOW: For approval © For your use • As requested For review and comment For bids due REMARKS. 0 Approved as submitted 0 Approved as noted ❑ Returned for corrections 0 Not marked on Action Read Resubmit copies for approval 0 Submit copies for distribution • Return corrected prints ❑ Prints returned after loan to us COPY TO are not as noted, please notify us. Signed: Printed Name: Email: Cook, P.E. ka littleonline,com CHARLOTTE-MECKLENBURG UTILITIES November 17, 2008 Mr, Charles Cook Little DAC 5815 Westp'ark. Drive Charlotte, NC 28217 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE SOUTH MECKLENBURG HIGH SCHOOL BUILDING REPLACEMENT TAX PARCEL# 207-211-33 C-MU TRACKING #600-08-678 In response to your request, a flow acceptance study of the subject site has been corrtpleted and the following has been determined: Charlotte -Mecklenburg Utilities agrees to accept the gravity sewage flow of 0 gallons per day (no additional flow) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see attached basin map and flow tracking form. Charlotte -Mecklenburg Utilities agrees to furnish water to the subject project, The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, dated October 2005, (WSMP # 05-01702 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR. However, Charlotte -Mecklenburg Utilities cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg Utilities system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. !f the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acceptance, this flow acceptance approval shalt be rescinded and a new flow acceptance request must be made. If you have any questions, you may contact me at (704) 391-5129. Barbara Gross Engineering Assistant New Services Section CHARLOTTE-MECKL.ENBURG UTILITIES Customer Service Division • New Services Section www.cmutiIities.corn 51i 0 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2'221 Fax: 7041393-2219 Charlotte -Mecklenburg Utilites �v'TP Service Areas with Basins State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance .for Sewer Extension Permit Applications (FTSE 0107) Project Applicant Name: Lit1e DAC Project Name for which flow is being requested: sout,h meekienbura, HS - E3ui1ding Replacem,ent: t1ore than one FTSE/ 0/07 may be required far (.1. single project if the owner a" WTI' is not responsible for all pump stations along the route of the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sur Creek MITP b, WWTP Facility Permit #: NCOD24970, NC0024945 NCOD24937 All flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg„ flow f. Total flow for this specific request g. Total .actual and obligated flows to the facility h. Percent of permitted flow used 14.91 66.8 00 77 82.6% 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow, List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. ClitTent Avg. (Firm/Design) Daily Flow, MGD 111. Certificati Statement: X.cry S ke4 , certify that, to the best of my knowledge, the addition of the volume of wastewater to be permittedin this project has been evaluated along the route to the receiving wastewater treatment facility and that theflow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 for which I am the responsible party. Signature of this form indicates accepta '.ce of this'pater flow. j7/i-57 Signing Official Date • f • t; INDEX OF SHEETS COVER SHEET STATION 0+00 thru 10+80 STATION !CHB° thru 17+93 SET W. SatvEYED BY, FUNS -PREPARED BY. DITE- •••••••• ••••1•13.,,•••.:•••Y • ••• \ • ••••• p•mima•.••••••••• MM.'S.. 4. CHARLOTTE -A UTILITY DI 01ARLOITE, • ENGINEERM SANITARY SEWERAGE %MY demo. • z (1" Sewer Lii rj.rfai, -by c?6 c.-4;riantoccr÷ 5a9edifil ged4embur-7 • 5thavi CK LEN BU RG 'A RTM ENT Ell CAROLINA, DIVISION ;TEM IMPROVEMENTS dna.. ma ad., • 11,1 Chilies/ • 1/V-i/G7 i<ertileeefieWet q_cq.oq1 313 9 N. PA, • 1^Inir., MT. LEGEND PROPOSED SAN. SWR..RAV---- EXSTING SAN. SWR R7W PROPOSED &SAN SWR. EXISTING 4. SAN. SWR FF-NCE GAS UNE %ATER LINE TELEPHONE CONDUIT MING GROUND ON PROFILE - TOWER LINE EXISTING EDGE OF PAVEMENT BRIDGE WWI BUILDING RAILROAD CREEK DR BRANCH PIERS GUARD RAIL UTILITY POLE PROPOSED SAN. sm. RODICLE • x x ) 1 •••\''s \';'s1 ._.• !III T T T tem nic SAN. swx MANHOLE FIRE HYDRANT GAS VALVE WATER VALVE TREE F-T-T450-fid t.ENGTH Of PROJECT DUE REVISION • , 1044 0 -W.': • . FEB- 5 Eel many MM. I AS - Willi b;.;;-.4 NES •-••••.""". •• UNITED STATES DEPARTMENT OF THE INTERIOR GEOLOGICAL SURVEY 2 mE. 4i 000 FEET (S. G.) I.1 3886000on 770 000 FEET {S, 00 0 Central Files: APS SWP 01/23/09 Permit Number WQ0033752 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation michaet.parker Permitted Flow 15000 Facility Facility Name South Mecklenburg High School Building 0 Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Owner Type Charlotte -Mecklenburg Schools Government - County Owner Affiliation Anthony Ansaldo 3301 Stafford Dr Charlotte Dates/Events NC 28208 Orig issue 01/20/09 App Received Draft Initiated 01/15/09 Scheduled Issuance Public Notice Issue Effective Expiration 01/20/09 01/20/09 Regulated Activities Requested/Received Events School Wastewater collection Outfall NULL Additional information received Additional information requested Waterbody Name Stream index Number Current Class Subbasin