Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0033721_Regional Office Historical File Pre 2018
A.`"4 NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue, Governor Dee Freeman, Secretary January 13, 2009 Mr. David Niekamp, Director of Retail Development Crescent Resources, LLC 400 South Tryon Street Suite 1300 Charlotte, NC 28285 Subject: Permit No. WQ0033721 Belgate Parcel A Tax Parcel #047-461-03 C-MU Tracking # 600-08-697 Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Niekamp: In accordance with your complete application received on January 6, 2009 we are forwarding herewith Permit No. WQ0033721, dated January 13, 2009, to Belgate Parcel A for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3, which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 610 East Center Avenue, Suite 301, Mooresville, North Carolina 28115 Phone: 704-663-16991 FAX: 704-663-60401 Internet: www.enr.state.nc.us An Equal Opportunity 1 Affirmative Action Employer - 50 % Recycled \ 10 % Post Consumer Paper NorthCarohna Vatiiraij Mr. David Niekamp Page 2 January 13, 2009 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 672 linear feet of 8-inch gravity sewer and the discharge of 43,250 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Mallard Creek WWTP (NPDES No. NC0030210) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system is the complete responsibility of Charlotte Mecklenburg Utilities. Charlotte Mecklenburg Utilities must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WQCS00001 permit requirements. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Michael Parker at (704) 663-1699. Electronic copies: Cc: Sincerely, for Coleen H. Sullins Meredith Moore, Mecklenburg County Development of Water Quality Barbara Gross, CMU Philip Edwards, Mecklenburg County Brannon Richards, Kimley-Horn and Associates Mooresville Regional Office, Collection System Permit File Surface Water Protection Central Files PERCS I NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with • the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 I 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or 2 b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733:•3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 13th day of January, 2009. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033721 3 Permit No. WQ0033721 January 13, 2009 OwnerIWQCS David N iekamp 400 S. Tryon Street Suite 1300 Charlotte, NC 28285 PE Brannon Richards, P.E. Kimley-Horn and Associates 4651 Charlotte Park Drive Charlotte, NC 28203 WQCSIWWTP Barbara Gross CMU 5100 Brookshire Blvd Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Belgate Parcel A, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000.as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking ail partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 4 COUNTY OF MECKLENBURG Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this day of by and between the North Carolina Environmental Management. Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Crescent Resources, LLC , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. ITNESSETH: The DEVELOPER is the owner of the certain lands lying in Mecklenburg County, upon which it is ovenients, said development to be known erecting and will erect dwelling units and othe as Belgate Parcel,A (hereinafter the Development). The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuannt to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System, 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declarat:i.on of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General. Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the tine of filing of the Declaration, the Belgate Property Owner's Association (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to pretest the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the partres hereto, the COMMISSION' and DEVELOPER do hereby mutually agree as follows: I . The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicabl.c permit provisions and law, The DEVELOPER shall transfer ownership and/or, control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the narne of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. The DEVELOPER shall not transfer, convey„ assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. NA-. r C III VTheDE\IELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common. elements and shall thereafter be properly maintained and. operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. TheDeclaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal. State, and local taxes and insurance. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be fundsreadily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association. Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. d. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities; or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER. shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System. and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal. System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system. and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance ofa permit. 9. The agreements set forth in numbered paragraphs 1.., 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER. for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaratio filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of th.e Association. IN WITNESS WHEREOF, this agreetr representative of the parties hereto on t FOR THE ENVIRONMENTAL MANAGEMENT COMMISSION Coleen H. Sullins, Director Division of Water Quality t was executed in duplicate originals by the dttly` authorized day and year written as indicated by each of the parties named below: ent Resources, LLC Name of DEVELOPER Print Name and Title (Date Ov r 2aV < nKimiey-Horn and Associates, Inc, Transmittal Date: January 5, 2009 Job Number: Project Name: Belgate Parcel A. Dee Browder Department of Environment and Nat 61.0 E. Center Avenue, Suite 301. Mooresville, NC 281 b 5 sending these by U S.'vta'ul fl Other: sending you Attached © Shop Drawit Other: Fast Track Permit 6= ed Er: Charlotte Park Dr€c, North Carolina TEL 704 333 5131 FAX 704 333 0845 1 Resources- Division of EjUnder separa.t:e cover via s/"Plans p the following Change Orders Copies Date 3 Description Application Fee to the Department of Environment and Natural Resources 01/05/09 01/05/09 01'05/09 01 /0 5/09 01/05/09 Narrative One original and one copy of the laast Track Application (FTA 12/07) One original and two copies of the Operat°tonal Agreement (Dcv (l?,Cfl One original and one copy of the Flow TrackinglAcceptance (FTSll l0/07) USGS Topographic Map These are transmitted as checked below: EjFor your use © As revue: icd and con Remarks: A? s. Dee Brow. Enclosed is on application Map. Please Copy to: Ei Approved as submitted Approved as noted Returned for corrections opies for apprt pies for distri cted prints °a iginal and one copy t the Fast -.Track Application, „Also included is the project narrative, Form Dev 02/03. Form FTSE 10/07, and Topographic ee to call me with any questions at 70.1-954-7483. Thank you, Signed Page 1 doc pprOF NORTH CAROLINA TY OF MECKLENBURG Permit No.[Ob7 DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (dl) and entered into this t 3' day of 1-cl-1- , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Crescent Resources. LLC , a.corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in Mecklenburg: County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as Belgate Parcel A (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the Belgate Property Owner's Association (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the commonelements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its, Disposal System until a permit has been reissued to the DEVELOPERS successor. Cl1177�d. r iCI7 !Y)1 -en e DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and I maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal- System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of.a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL Crescent Resources, LLC MANAGEMENT COMMISSION Name of DEVELOPER Coleen H. Sullins, Director Division of Water Quality i I 1.51 09 (Date) By: (Signature ei/C4 it- • fr'- f/' Print Name and Title (Date) Pau , L.1 2v& LYll)Td. r 'Sr n'1ur2 Charlotte Mecklenburg Belgate Parcel A Charlotte, NC Project Descripti The purpose of the above referenced project is to provide sewer service liar the Ct'esc.ent l esourc.es er elopment, Wastewater will flow via gravity through a proposed 8-inch sataitarj' se tier. The existing water and sewer has been extended to this area (Permit 208542) and is owned and maintained by Charlotte -Mecklenburg' Utilities, Wastewater from Belgate Parcel A is to be treated at the Mallard Creek Wastewater Treatment :Facility (WWTF). The proposed 672 feet of 8-inch sanitary sewer will serve approximately 25,000 SF of re'taail and 'approximately 25,000 SF of restaurant. The resulting flow is estimated to be 43,250 gallons per day, Site Description The existing site is located north of University City Boulevard and west of Ikea Boulevard.. The proposed sanitary sewer will flow along a proposed private drive within a private easement. The wastewater will flow. east from Parcel A to the existing 8-inch sanitary sewer manhole (CMU fob 0100-07-646) on the west side of Ikea 'Boulevard_ Sewer laterals will be extended for provide service for each lot. Q Z z b, 704-333-5131 Phone Number USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner!Permittee: • la. Crescent Resources, LLC Full Legal Name (company, municipality, HOA, uti lb, David Niiekamp Director of Retail Development ity, etc. Application Number: (to be completed by DWQ) Signing Official Name and Title (Please review 15A NCAC 2T .01 The legal entity who will own this system is: 0 Individual ❑ Federal 0 Municipality 0 State/County 0 Private Partnership ® Co d, 400 S. Tryon Street, Suite 1300 Mailing Address NC State 980-321-618't 1 i. Telephone 980-321-6170 Facsimile 2 Project (Facility) Information: 2a. Belgate Parcel A Brief Project Name (permit will refer to this name 3. Contact Person; 3a, Brannon Richards, PE, Project Manager Charlotte City 28285 Zip Code djniekampr' ?cre E-mail 2b. Mecklenbu County Where Project is authorized signing offlcia oratton 0 Other (specify): en -re Name and Affiliation of Someone Who Can Answer Questions About this Application 3c, Brannon,richards E-mail Project is New ❑Modi g permit) If Modification Permit Nory:. � fica(on existing tion f a ,. Owner is 0 Public (skip to Item B(3)) 2,a. if private, applicant will be: Private (go to Item 2(a)) 2b. If sold, facili 0 Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc, - skip to item B(3)) Selling units (lots, townhomes, etc - go to Item B(2b)) Charlotte Mecklenburg Utilities Owner of Wastewater Treatment Facility (WWTF) Treating Mallard reek_ P Name of WWTF. _.n �......,..... �.e..-___.�e�-..-_ ante urces,cam kimley-horn.com es owned by a (must choose one 0 Public Utility (Instruction C) Homeowner Assoc./Developer (Instruction D) er From This Project 4b. NO030210 . WWTF Permit No. Charlotte Mecklenburg Utrl 5b. 8-inch I Gravity 5c. 208542 Owner of Downstream Sewer Receiving Sewer Size 0 Force Main Permit # of Downstream Sewer (Instruction E) The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑Apartments/Condominiums ❑ Mobile Horne Park O School Restaurant ❑ Office Retail (Stores, shopping centers) 0 Institution Hospital 0 Church 0 Nursing Home ❑ Other (specify): 100 % Domestic/Commercial % Industrial (attach description.) (RO: contact your Region Pretreatment staff) % Other (specify): I Office Volume of wastewater to be allocated or permitted for this particular project: 43,250 gallons per day 'Do not include future flows or previously permitted allocations If the permitted flow is zero, "indicate why: O Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line O Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA t?t'07 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for, the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in 1 Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use; data in accordance with 15A NCAC 2T .0114 (f). i 25,000 SF Restaurant (full service) ` 40ga1/day/seat * 4 seat/100 SF = 40,000 gpd 25,000 SF Retail ' 130 gal/day/1,000 SF = 3,250 gpd TOTAL = 43,250 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 8 672 i New Gravity 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator wIMTS Force Main Size Force Main Length Pump Station Location 1D -- -. (self chosen - as shown on planslmap for reference) Design Flow I Operational Point (MGD) i GPM @TDH Power Reliability Option 1 - permanent generator w!ATS; 2 - portable generator w/MTS Force Main Size Force Main Length . Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator wIMTS Force Main Size Force Main Length, • 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? • ❑ Yes ® No If Yes, permit number of 2 treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07 14, Have the following permitslcertifications been submitted for approval for the system or project to be served?' Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No Z N/A Sedimentation and Erosion Control Plan? Yes ❑ No ❑ N/A Stormwater? Yes ❑ No ❑ N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T 0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Elizabeth McMillan , attest that this application for Belggate Parcel A_ has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note.. In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation, SigninSignature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY Cl) TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC, REFER TO 15A NCAC 02T .0305 Z e 0 2. Professional Engineers Certification: (Signature of Design Engineer and Project Name) 1„ Brannon Rich +s PE , attest that this application for tdcate Parcel A has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Farce Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance,. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I .have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215, 6A and 143-215.6B, any person who knowing makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10 000 as well as civil penalties up to $25, 000 per violation. 2a, Brannon Richards Professional Engineer Name 2b. Kimley-Horn and Associates, inc. Engineering Firm 2c, 4651 Charlotte Park Drive, Suite 300 Mailing Address 2d, Charlotte C ity 2g. 704-333-5131 Telephone 2h. 704-333-0845 Facsimile 2e. NC 2f. 28217 State Zip 2i, Brannon.dsskirnley-hom.corn E-mail NC PE Seal ignature & Date CHARLOTTE-MECKLENBURG UTILITIES December 15, 2008 Mr, Brannon Richards Kimley-Horn and Associates, Inc. 4651 Charlotte Park Drive Charlotte, NC 28217 SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE BELGATE — PARCEL A TAX PARCEL# 047-461-03 C-MU TRACKING # 600-08-697 In response to your request, a flow acceptance study of the subject site has been completed and it has been determined that Charlotte -Mecklenburg Utilities agrees to accept the gravity sewage flow of 43,000 gallons per day (1,000 restaurant seats x 40 gpd/seat; 25,000 ft2 retail x 120 gpd/1,000 ft2) from this project for transmission to the Mallard Creek Wastewater Treatment Plant; NPDES permit number NC0030210, for treatment, This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works, Please see attached basin map and flow tracking form, Charlotte -Mecklenburg Utilities agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, dated October 2005, (WSMP # 05-01702 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR, However, Charlotte -Mecklenburg Utilities cannot guarantee a constant pressure or quality of flow, Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved, Connection to the Charlotte -Mecklenburg Utilities system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction, If the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acce tance:: and a ment for service connections have not been made within one year of issuance of this flow acceptance, this flow acceptance approval shall be rescinded and a new flow acceptance request must be made, If you have any questions, you may contact me at (704) 391- 5129. Barbara Gross Engineering Assistant New Services Section CHARLOTTE-MECKLENBURG UTILITIES Customer Service Division • New Services Section www.cmutilities.com 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 Fax: 704/393-2219 Charlotte -Mecklenburg Utilites WWTP Service Areas with Basins State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—10/07) Project Applicant Name: Kimley-Horn and Associates, Inc. Project Name for which flow is being requested: Belgate, Parcel A More than one FTSE-10/07 may he required for a single project the owner of the WWTP is not responsible, for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Mallard Creek WWTP b. WWTP Facility Permit #: NC0330210 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg, flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used. All flows are in MGD 12.33 1.21 7.51 72,7% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD III. Certification Statement: , certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local. established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form indicates acceptance ofthis tewater flow. Signature Date Signing /2'/J7/t, ure ■ Proposed 8" Sanitary Sewer Streams Title Topographic Map (Derita and Harrisburg 7.5 Minute Quaads) Prepared For oject Bel gate Parcel -A Mecklenburg County, North Carolina Da I /5/09 Project Number 5 Prepared. By KimleyHorn and Associates, Inc. Permit Number WQ0033721 Central Files: APS SWP 01 /1 2/09 Permit Tracking Shp Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer michael.parker Permitted Flow 43250 Facility Facility Name Belgate Parcel A Location Address Owner Status Project Type In review New Project Version A Permit Classification Individual Permit Contact Affiliation Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Crescent Resources Dates/Events Owner Type Non -Government Owner Affiliation David Niekamp, Development Dir 400 S Tryon St SteIV0 Charlotte NC 282010103 Orig Issue App Received Draft Initiated 01/13/09 01/06/09 Regulated Activities Restaurant Retail Wastewater collection Outfall NULL Scheduled Issuance Public Notice Issue Effective 01/13/09 01/13/09 RequestedlReceived Events Additional information requested Additional information received Expiration Waterbody Name Stream Index Number Current Class Subbasin ,oF wA1- 6, Beverly Eaves Perdue, Governor Dee Freeman, Secretary North Carolina Department of Environment and Natural Resources CO r y Coleen Sullins, Director 0 -c Division of Water Quality February 11, 2009 David Niekamp 400 S. Tryon Street Suite 1300 Charlotte, North Carolina 28285 SUBJECT: Belgate Parcel A Permit No. WQ0033721 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on January 30, 2009. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from htto://h2o.enr.state.nc.us/ndou/ndpuapps.html#Sewer. if you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. incerely, faj.„ RobertKrebs 'Surface Water Protection Regional Supervisor Enclosure Cc: Surface Water Protection Section Central Hes (certification page only) Brannon Richards, Kimley-Horn & Assoc. Barbaro Gross, CMU ne NorthCarolina Naturally Pretreatment, Emergency Response and Colledion Systems Unit Internet http://h2o.enr.nc.state.us/ndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recyced/10% post -consumer paper Permit No. WQ0033721 January 13, 2009 OwnerlWQCS David Niekamp 400 S. Tryon Street Suite 1300 Charlotte, NC 28285 PE Brannon Richards, P.E, Kimley-Hom and Associates 4651 Charlotte Park Drive Charlotte, NC 28203 WQCS!WWTP Barbara Gross CMU 5100 Brookshire Blvd Charlotte, NC 28216 Complete and submit this, form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, P rmit modificatio s ar r _ tri d for an changes resulting in non-compliance with this permit., rectultions or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION fl Partial Egi Final 1, Brannon Richards , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (EI periodically, Q weekly, D full time) the construction of Belgate Parcel A, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000.as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: 'CAR '#a. WITH REQUIRED THIS FORM & SUPPORTING DOCUMENTATION 'NARE© ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. K`m1ey-Worn and Associates, Inc, Date: January 29, 2009 Job Number: KHA 015253026 Project Name: Belgate Parcel A — WQ0033721 Suite 300 4651 Charlotte Park Drive Charlotte, North Carotin a 28217 TEL 704 333 5131 FAX 704 333 0845 To: Dee Browder vine Regional Office -- Surface 610 E. Center Avenue, Suite 301 Mooresville, NC 28115 We are sending these by U.S. Mail E' Other: ?edEx. © Hand Deliver We are sending you © Attached Shop Drawings Under separate cover via Prints/Plans Other: Engineer's Certification Samples 1 1 Specifications t 7e following iten Change Orders Copies Date 01/29/09 01 /29109 No, Description WQ0033721 Engineer's Certification Parcel A Sanitary Sewer Record L?rawin.gs These are transmitted as checked below: r Approved as submitted 0 Approved as noted For review rand comment 11 Returned for corm cttons For your use CAs requested Remarks: Ms, Dee Browder - Enclosed is one copy of the engineer sanitary sewer main (WQ0033721). Please id me know if you have any questions or need any additional information. Thank you, Resubmit Submit Return Copies for approval Copies for distribution Corrected prints Copy to: Emily Pendleton, File Page 1 n and record drawings for the Parcel A Signed Brannon ebards, PE • engineer ce e'on i 29.2009.40c