Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCC216397_Site Plan or Location Map_20211117
TOWN OF FUQUAY-VARINA WAKE COUNTY, NORTH CAROLINA CONSTRUCTION DRAWINGS TOWN OF FUQUAY-VARINA PROJECT #SP-2019-24 'I st SUBMITTAL TO TOWN OF FUQUAY-VARINA: MARCI-I 27, 2020 2nd SUBMITTAL TO TOWN OF FUQUAY-VARINA: JULY 14, 2020 ' 3rd SUBMITTAL TO TOWN OF FUQUAY-VARINA: SEPTEMBER 30, 2020 k REZONING CONDITIONS OF APPROVAL 4th SUBMITTAL TO TOWN OF FUQUAY-VARINA: DECEMBER 18, 2020 BR DST ET CASE # REZ-2018-19 �-' I F�IJ QUAY -VA- P I NA PROPOSED CONSTRUCTION DOCUMENTS SHALL MEET THE REQUIREMENTS OF THE ASSOCIATED APPROVED FOR COMPLIANCE MASTER PLAN DOCUMENT & RELATED MAPS PER THE ABOVE REFERENCED CASE NUMBER. These plans have been approved for CaMp1l35cO wits, the Totivn Cade of Ordinances & Standard Specifications & Coristructian N. MAIN STREET Details s s nf5 8 conditions he%by incorporated by refer c� t Signat ire ate QUANTITY TABLE ITEM UNITS 6" PUBLIC WATER LINES 342 LF s" PUBLIC WATER LINES 90 LF DRAWING INDEX D-05 WATER DETAILS 1 VICINIff MAP SEWER LINES 392 LF 8" PUBLIC D-06 WATER DETAILS 1► SCALE: 1" = 500' 15" STORM DRAIN LINES 105 LF 18" STORM DRAIN LINES 447 LF C -00 COVER SHEET D-07 WATER DETAILS ►►1 24" STORM DRAIN LINES 398 LF C-01 CIVIL NOTES D-08 SANITARY SEWER DETAILS 30" STORM DRAIN LINES 155 LF C-02 EXISTING CONDITIONS PLAN ❑-09 STORM DRAINAGE DETAILS 1 50' RIGHT OF WAY ROADWAY 430 LF SIDEWALK 553 LF C-03 DEMOLITION PLAN D-10 STORM DRAINAGE DETAILS 1► GOVERNING AGENCIES: 8' SIDEPATH 372 LF C-04 ZONING DISTRICT PLAN EC-01 EROSION CONTROL PLAN - INITIAL PHASE PLANNING/ZONING/LANDSCAPE: STORMWATER CURB & GUTTER 1776 LF C-05 OVERALL SITE & PHASING PLAN EC-02 EROSION CONTROL PLAN - CONSTRUCTION PHASE TOWN OF FUQUAY-VARINA PLANNING DEPT. TOWN OF FUQUAY-VARINA ENGINEERING DEPT. REGULATORY SIGNS 3 134 N. MAIN 5T. 134 N. MAIN ST. C-06 SITE LAYOUT EC-03 EROSION CONTROL DETAILS 1 FUQUAY-VARINA, NC 27526 FUQUAY-VARINA, INC 27526 919-753-1870 919-753-1035 C-07 NORTH STREET ROADWAY IMPROVEMENTS EC-04 EROSION CONTROL DETAILS 11 CONTACT: MS. PAM DAVISON CONTACT: MR. MATT POLING, PE SITE INFORMATION C-08 UTILITY PLAN EC-05 EROSION CONTROL DETAILS 111 ENGINEERING EROSION CONTROL: LOCATION: 6071609 NORTH STREET FUQUAY-VARINA, NC 27526 C-09 GRADING & DRAINAGE PLAN EC-06 EROSION CONTROL DETAILS ►V TOWN OF FUQUAY-VARINA ENGINEERING DEPT. TOWN OF FUQUAY-VARINA ENGINEERING DEPT. COUNTYi PAR PARENT PIN: WAKE 066710-7979 C-10 STORMWATER CONTROL MEASURE PLAN & SECTION EC-07 EROSION CONTROL DETAILS V 134 N. MAIN FUQUAY-VARINA, NC 27526 134 N. MAIN FUQUAY-VARINA, NC 27526 DB1PG: 0667-21-0121 16198 /81 Ci-1 1 SHERR►LL ROAD PLAN & PROFILE SW-01 PRE -DEVELOPMENT DRAINAGE AREA MAP 919-753-1039 919-753-1035 CONTACT: MR. TRACY STEPHENSON, PE CONTACT: MS. JENNIFER MITCHELL, CFM NEW RECORDED MAP: _ BM2020 /PG02098 Q, C-12 BREWING DRIVE PLAN & PROFILE SW-02 POST -DEVELOPMENT DRAINAGE AREA MAP US ARMY CORPS OF ENGINEERS (USAGE) ZONING: NMU, UMU C-13 LIGHTING PLAN SW-03 STORM DRAINAGE INLET AREA MAP USAGE RALEIGH FIELD OFFICE 3331 HERITAGE TRADE DR. SUITE 105 ACREAGE: 5.22 AC L-01 LANDSCAPE PLAN A 7. 7 BREWERY ELEVATIONS WAKE FOREST, NC 27587 919-554-4884 CURRENT LAND USE: VACANT PROPOSED LAND USE: _ BREWERY, DISTILLERY, L-.02 LANDSCAPE DETAILS A7.2 BREWERY ELEVATIONS CONTACT: MR. JAMES LASTINGER BREWERY BAR, MANUF MANUFACTURING, — D 07 SITE DETAIL A1.3 RESTAURANT ELEVATIONS RANT,RETAIL, RESTAUTILITY AGENCIES: SALES/SERVICE ❑—O2 SITE DETAILS 11 A 1.4 RESTAURANT ELEVATIONS WATER & SEWER NCDENR-DWQ SEWER STANDARDS & SETBACKS ❑-43 SITE DETAILS ►11 A �. 5 CULTURAL COOKING ELEVATIONS TOWN OF FUQUAY-VARINA NCDENR RALEIGH NMU PUBLIC UTILITIES DEPT. REGIONAL OFFICE LOT WIDTH: 20' MIN, 96MAX ❑-04 SITE DETAILS IV /4 7 PAVILION ELEVATIONS 1415 HOLLAND RD. 3800 BARRETT DRIVE - FRONT SETBACK: MAX .6 FUQUAY-VARINA, NC 27526 RALEIGH, NC 27609 SECONDARY FRONT SETBACK: _18' 10' MAX 919-567-3911 919-7914232 SIDE SETBACK: X MIN CROSS —ACCESS EASEMENT: CONTACT: MR. ,JAY T. MEYERS, PE REAR SETBACK: - TMIN ORIGINAL CONSTRUCTION MAX BUILDING HEIGHT: 50' MAX THE RECOMBINATION, STORM DRAINAGE, AND CROSS -ACCESS EASEMENTS REFERENCED ON C-05 PLANS FOR STAMPED NCDENR-PUBLIC WATER SUPPLY NCDENR DIVISION OF WATER RESOURCES UMU HAVE BEEN RECORDED AT WAKE COUNTY, REF. BM 3 RALEIGH REGIONAL OFFICE LOT WIDTH: 20' MIN, 150' MAX 2020, PG 2098. APPROVAL 3800 BARRETT DRIVE FRONT SETBACK: _ 12' MAX RALEIGH, NC 27609 SECONDARY FRONT SETBACK: SIDE SETBACK: 6' MAX MAX Developer. Architect. Surveyor: Landscape Architects Civil Engineering: 919-791-4232 REAR SETBACK: 3' MIN T MAX BUILDING HEIGHT: 70' MAX Aviator Gold Leaf, LLC Architect Kurmaskie Associates, Inc. Mauldin -Watkins Surveying, PA Southwell Design, PLLC The Curry Engineering Group, PLLC BEFORE YOU DIG, Projects shall be constructed according to the Standard Specifications and PARKING 209 Technology Park Lane 1030 Washington Street P.O. BOX 444/1301 W. Broad Street PO Box 37178 NC License # P-0799 CALL Details in effect at the time the project receives Town approval for PROVIDED PARKING: 173 REGULAR SPACES - Fuquay-Varina, NC 27526 Raleigh, NC 27605 Fuquay-Varina, NC 27526 Raleigh, NC 27627 PO Box 2018 construction. The Contractor must have a complete set of stamped plans and specifications on the jobsite any time work is being performed. Stamp 8 ADA SPACES 919.567.2337 919.846.1600 919.552.9326 919.272.6729 205 S. Fuquay Ave shall be affixed to plans below: IMPERVIOUS AREAS Contact: Mark Doble Contact: Tim Kurmaskie Contact: Wayne Mauldin, PLS Contact: Adam Southwell, PLA Fuquay-Varina, NC 27526 PROPOSED BUILDING: 54,352 SF (1.25 AC) email: mark@aviatorbrew.com email: tim@architectskt.com email: adam@southwelldesign.com 919.552.0849 (o) PROPOSED PAVEMENT: 73,134 SF (1.68 AC) 919.8$0.9857 (m) PROPOSED SIDEWALK: 19,126 SF (0.44 AC) Contact: Don Curry, PE NORTH CAROLINA TOTAL IMPERVIOUS: - 146,612 SF (3.37 AC 65% ) ( ) email: don cur en com rY 9• ONE CALL CENTER www,ncocc.org REVISIONS PROFESSIONAL'S SEAL CONSULTANT CLIENT 1 7/1412020 TOFV COMMENTS 2 2/181 02 TOFV COMMENTS011 CONS TRUC TION DRA WINGS 3 12I18l2020 TOFV COMMENTSlFINAL Aviator Brewing Company • � ENG�N J � S �� � FF T (9191 552-0849 205 3. Fuquay Avenue U� u, p (919}552-2043 Fuquay-Varina, NC 27526 209 Technology Park Lane _ urr EST. © 1¢ Fuquay-Varina, NC 27526FA v--- , A VIA TOR BREWING COMPANY J N STATUS 368 3 _ °�l 919.567.2337 �A�� o I;�.� roc t�������o �y Gj �1� . Contact: Mark Doble • o RELEASED FOR CONSTRUCTION [%; ..... �� ENGINEERING NC LIC. No. P-0799 * COVER SHEET mark@aviatorbrew.com w DATE: FEBRUARY 3, 2020 HORZ. SCALE: N.T.S CMOO o FILE NO. 2020-002 ORIG. SHEET SIZE: 24 x 36 1211$12020 J a 0 0 0 q I~ 0 W I= III U w J_ ILL III w r S9 L0 0 z M z 0 U F- co z 0 0 6 z a z Of Q 0 ILL w Of m 0 M CV O O O [V SN N z m� LNIR wo o J Ev LLGO Fes- N Q� ai . 0 �_J hJ d wm r 0� GRAVEL Im DRIVE cl m -�_ i 71 'I5. RCS' 4 - 1� I INV-42.641 {FUL DIRT I I rr ASPHALT - x { - ------ -_-- ---_ --- DRiVF b I 10'. I J - }I �� irty 4z .$1 L, I - 1= JUAN V. MARTINEZI. UJ m I 11 I � CD C) UJ AKINS PROPERTIES LLC l EVANGELINA. MARTINEZ � AKINS PROPERTIES, LLC IiNV 2o.1a Q_ CM z u� D.B•12040, PG. 1315 b.13.5182, PG.809 I q.8.9052, PG.1088 - o ZONING-RLD ZONING RLD I >w ZONING- DC-1 I I 1-11Ln AKINS PROPERTIES LLC z USE: RESIDI=NTiAL USE: RESIDENTIAL W. I USE: RESIDENTIAL Pp ( rn .sr 'TION D.B.13046, PG,883 � m NI( QwPi GRAVEL ¢ w iN ,`4 I DROVE TRANSITION TO FLUSH ZONING-O&k - - - - 0- },._. { USE: RESIDENTIAL - - - - - F TRANSITION TO 24" STANDARD - _--- -.- .-T DRIVE IVE 11 o { NEW ROUVIPROPERTY LINE, ROW 20' PUBLIC UTILITY � ram. • '"�_\ CURB & GU TE o DEDICATION = 5,719 SF, 0.13 AC 24" STANDARDIII, A + . � &ACCESS 6 COMPOSITE Q 20' CURB &GUTTER 3Q S,-� T.4414I LEGEND: - 2 j i (R1-1) GQP "' 6' COMPOSITE ) �': ZONING -HI 1 11_UW:EYIENT_� I - STOP SIGN PRIVACY FENCE USE: RESIDENTIAL ` 18. TWO SETS OF SPEAKERS SHALL BE INSTALLED ON EACH SIDE OF THE 8' CQNC. SIDEPATH . BUILDING MOUNTED LIGHT I BULK CO2 STORAGE TANK - - - R25' , // �1.7-. �. _-°$•�-�°��_ ='" PAVILION ANGLED TOWARD THE GROUND. THE PERIMETER OF THE PROPERTY I I BOLLARDS, TYP. SHALL HAVE MICROPHONES INSTALLED TO MEASURE THE SOUND VOLUME - - - R5 24" STANDARD FFE=412.00' I / I FAVkNG THE PR(�PFRTY PRIMARY SETBACK FFE=414:a0 BREWERY 0 - - CURB &GUTTER - - - - / GRFVE M r_: �, r u .,-� 37,426 SF I . HE OHE OHE .L -9Fi4MEL� �' �'P�[4 J I I / - - -c� - pROHEL OHE -- OHE PRIMARY SETBACK (MAX 12') IIV o / DRIVE 20 PRIVATE STORM �,, 4 _...DRAINAGE .EASEMENT ..... - -1 I - - ..._-. __�-.--:�-- CROSSWALK - - STAIRS TO UPPER LEVEL i . ET o S T R E - -- ----- QN' � �' I �\ - I - - -------_--- .. ----- ., . --- . '- - I .. rm ,- ..a, ,. ,:�. ,� f STANDARD �A� l " rx LCICATION dF'NA7ER INE PER'IL�FV G!S N - I CONC. SIDEWALK. I fr" R40 R25 . TRANSITION TO 24 D R26..___� R25 t STE ! ' - - ` SECONDARY SETBACK6' ,`s SIDEWALK RAMP _---_W�-_- .__yet_ _ ---. I (MAX.( ) R45' R25 CURB &GUTTER I SIDEWALK RAMP . -"-- E 2 �„u wl HANDRAIL / I I I I SECONDARY SETBACK I I i I LANDING w1 HANDRAIL VEHICLE GAT (SEE DETAIL) - - n _ -.. _. r c ___-- -- - -- �-OHE RISER I oHE n �2 - E S L H t �o IN 410 �7 I } STAIRS 30" STANDARD PROPOSED ROW ,j...,, -. T ., LLl - -- - - ROOM I 50' ROW I i .�� -_-= _ I 1.T 25' BC1BC - - - ALhJANI�RO GONZH.L,...,_. w I: j �` 6' GONC. SIDEWALK I CURB &GUTTER ` c,RAvs� I 1- - - - - - - - _.. - - - - - - - - - - - - - - - LANDING I VALENTINA GONZALEZ L,R.IVE� I :; _-. -- R4�." J STOP SIGN �� 10'x70' SIGHT . . P 4 _ _ �i _ - - 1.10'x70' SIGHT C I 8.3' .. .. B. 23 DISTANCE I (R1-1) DISTANCE . . . ' � I 0 M 1993, PG 3 I \ , \ \ CR I I . ` 0 10'0a I ' R25' , STOP SIGN (R1-1} 11+00 S. H' E R R .I L L ROAD 12+00 \ sign 1 - . - - \ I 50' RIGHT -OF WAY lid 1 - 24" SOLID WHITE STOP BAR cic \ lid �� f48.' , 1 . -___ - � AP , - --- O 0 si n, \ OHE--�,w - HE � . -__ t -- -� --- _ -W, - Vq, ___._ ..� W \ g �I - - ---tJrit - - pH Orin \ \ _ \ OHE \ y ` t". VARIABLE WIDTH q FFEEN E �U DRIVE r EfJ�'E � GRA I \ r� GN I , /` PUBLIC STORM ¢ Rlrl �\ � •, ' / DRAINAGE EASEMENT 30" VALLEY CURB &GUTTER \ A "o r LAURENCIO GARCIA �\ \ .� 1\V ! MARIA A. FONSECA DE GARCIA ST-50-28 \ � %\, �'l ,' "I I � TRANSITION TO FLUSH DANIEL A GARCIA FONSECA MODIFIED /' DB. 13364,PG,258 "! ` INV-412 74 ,\ �� / 1 � BM. 2002, PG.1893 X/ � ZONING-RLD\ / 0 USE: RESIDENTIAL I . \ / / 1 \ A 0 STREET LIGHT CONCRETE SIDEWALK ■-H PARKING LIGHT /I MODIFIED W WHEELCHAIR RAMP ASPHALT PAVEMENT ` - - - ROADWAY CENTER LINE VALENTIN MARL-INEZ I i - - LOT LINE . ASPHALT MILLINGIOVERLAY AKINS PROPERTIES LLC 1 AKINS LLC JEAN R. MARTINEZ D.B.16629, PG.893 d.6,11825, PG. 154 � D.6.8547, PG.1302 ` RIGHT OF WAY LINE I ZONING-RLb ` ZONING-RLD ZONING-RLD l PHASE LINE USE: RESIDENTIAL USE: RESIDENTIAL } USE: RESIDENTIAL - - - - SETBACK LINE GRAVEL SURFACING TRANSITION TO 24" S�ANDARD I AKINS PROPERTIES LLC - • • - - • - • • - SCM LIMITS CURB &GUTTER - - D.B.13306, PG.2568 - - - EASEMENT _ - - - - - - - - B.O:M.1989• PG.310 VALLEY CURB &GUTTER BUILDING STOP SIGN (R1-1) 20' SCM ACCESS ZONING-RLD STANDARD CURB & GUTTER 20' PUBLIC x x x- EASEMENT x x x USE: RESIDENTIAL - UTILITY 1 SPILL CURB &GUTTER ' EASEMENT x FENCE { i r 1 • ,. I - ^- s_ - - �� - - EASEMENT PRIVACY FENCE 3 + wm { { 8' COI�C. SIDEPATH X X X X X X ACCESS 1 16 PARKS @ 9' CU TAN ARD r _ x x x x x� EASEMENT -- 9' DAVID W. CASSIDY a { ;'' } cuR & G TT - - - - GENERAL NOTES: I_- -- - . D.B-6452, PG.41 I ST P SI NIl - I RT F R5' 1. ALL CONSTRUCTION SHALL BE PER TOWN OF FUQUAY-VARINA STANDARDS ZONING DC-1 U (R1-) 12 PARKS 9' 8' 9 PARKS 9' 1 $' 11 PARKS 9' 1 9' I R15 2 PARKS @ 9' AND SPECIFICATIONS. @ @ @ 24 StjLID WHITE N USE: VACANT R25 , I ? 5 STOP BAR R5' R5' '� 2. ALL DIMENSIONS ARE IN FEET AND TO BACK OF CURB UNLESS OTHERWISE I I n,h `- - { �oP 4 �. R5. R4 . �„ R4- . f15 I„ puia1 ..., HI,b CONC:: . � 24" SO.LID WHITE WCR RT .W- \\ T �- ' � NOTED z } 24" SOLID: WHITE - - R5.5 N R 5' 3 PARKS @ 9 3. ALL SITE ELEMENTS ARE PERPENDICULAR TO EACH OTHER UNLESS -- - -� .� -- C.r l l 11. PAVEMENT" 9' 9' 9' STOP 13AR - R3' . \ OTHERWISE NOTED. R5' ..STOP BAR R& R3 R3' �1 4' R5 1 \ tROSSW LK - _ - . _ _ _ - - . . _ -1.: - . - STOP-SIGN� E A 6 COMPOSITE PRIVACY FENCE . - V HI R GATE I ) - R1-1 E D � • - �� 4• CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, RIGHT-OF-WAYS DETAILS) R3 INv s.as+ WCR 7 PARKS 9'15 �, _ 6 PARKS @ 9' oo $PARKS @ 9' ( ) R3' \ VARIABLE WIDTH PRIVATE AND UTILITIES, PUBLIC OR PRIVATE, BEFORE WORKING IN THESE AREAS. DAVID W. CASSIDY I @ °° 2 HIC PARKS @ 9 - $, - , \ SCM ACCESS & 5• PROTECT ALL PROPERTY MONUMENTS AND PINS. MONUMENTS AND PINS } �5 ;R50 R3M D DURING CONSTRUCTION SHALL BE REFERENCED EA EMENT THAT WILL BE DISTURBED URIN CHERYL ANN CASSIDY , _ d MAINTENANCE S a_ ; 1 I .. R3 _. ;L. .. - a D,B.13 r 70-508 I f R3 -11 A' �` AND REPLACED BY A LICENSED LAND SURVEYOR AT THE COST OF THE I COC, EWALKI R5 SERGIO R. GODOY JR ZONING- DC-1 8' C�INC, SIDEPATH - CONTRACTOR. I I / WCR N PATIO WO / \ '1B ��_ 1 D.B,15503, PG.2331 USE: VACANT l I . - ARKING V 6. CONTRACTOR SHALL MAINTAIN THE SITE IN SUCH A MANNER THAT WORKMEN } I CULTURAL COOKING DING ZONE ONLY 11 c9 �$ 8'0•M•1989, PG'310 \ AND THE PUBLIC WILL BE PROTECTED FROM INJURY AND ADJOINING I 2,726 SF �/ ,,�'�� ZONING-RLD MSE RETAINING WALL PHASE 2 / \ (R7 6), TYP 3 2A . i V ..:. FFE=414.00 �' \ _X� ! USE: RESIDENTIAL PROTECTED FROM DAMAGE __. --_ ___ ____ ._- -_ PROPERTY PROT 0 } ,.:;: ... / \ 1� g' 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE UPON ® v. ....::.:::::.::::::::.:: / PAVILION \ z ° LOADING AREA { 1..` '..:::._ ":::...::.::,.,:.::::::. ° : ::.;; .. ;;c:::::;;::•.-.......... _ - _ COMPLETION OF THE PROJECT AND AT LEAST ONCE A WEEK DURING ...`,"........................ ::::.:::::: f�3 .. I I } 844 SF \ $ ..... CONSTRUCTION. ...................................:....:..:::::::::• :•:::.::::.:::. :::::::.:::..:: :::::::.:::::::::.:::.:: :::..::: \ - - RS .. a a.................:::::.:::::.::::::::.:.::.:::::::::.::::..::::::::.:: FFE-410.50 -a SAND FILTER ?:i :ii:.I::::::ii i::: }?;i; :rrr: rrrr:ii.r ::u:::::::.:: :::::. WATSON D. ADCOCK �, ....... .-1- a 8. CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR II <:I::�":::.:::::::. ::::::::..: :.:::::::::..:::::::::::.:.:.:::::::::.::::::::.::::::.:.:::...::. .�, �\ / SCM 1 D.B.15197, PG.2130 ::'.'::; : :i:: - - . - - - :.::.:::• D N MO NTED LIGHT WCR �' `r' MATERIAL DUE TO CONSTRUCTION OPERATIONS. ALL STREET SURFACES, Milt x I i :;;a:: ::::.: l :..:::. BUIL I G U WG C� 1 ZONING- DC-1LLI { .I I ,::::: �: ::::::::: "VI ;F' \ / / R5' .. UTILITY POLES, CULVERTS, DITCHES, CURB AND GUTTER OR OTHER USE: RESIDENTIAL C 1 { ;:• •::•: t RISER STAIRS TO PHASE 2 CANOPY OUTLINE \ / `9 \ STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY MANNER AS A INV-413 r:::::: m- i( ...:,:?- :. \ / { , � :;;;' f• : ROOM UPPER LEVEL \ WCR v RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED BY THE solL } i I I::: :::; :.::f:-: 11' . DRIVE :.........I.. ...:::a:.:yg#:.:;•:;.: GAS FIREPIT, TYP. � STANDARD CONTRACTOR IN ACCORDANCE WITH THE APPROPRIATE SPECIFICATIONS. :: `- - - - 1 ;, 40 f•. COLUMN, TYP. GREEN LAWN 5 SIDEWALK CURB& GDTER 9. IF DEPARTURES FROM THE DRAWINGS OR SPECIFICATIONS ARE DEEMED I W ::):I':: ::;::.;:: ;;:::-;::::`:;;::;;: 8 CROSSINA.LK . INv412: CL TO ROW t :•.. •::f;• CIVIC AREA = :::., :: --:' : NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND PP I I .11 I ;i:i ::: :::+�: ..:::':::. 1 ' 0.80 AC WRITING TO THE FACILITY 1 SONS THEREOF SHALL BE SUBMITTED IN e I RF�4 F ... �:; . :... ` `:, 30.5 CANOPY OUTLINE 6' SIDEWALK ?: ;:.j: ".: ANT 5 �! ; ;;;..t..: RESTAUR ;:.:....::`.:.: ER FOR REVIEW. NO DEPARTURES FROM THE CONTRACT DOCUMENTS mil BC DESIGNER :::::.:..._ r.:_::::.:: AKINS PROPERTIES, LLC cav CL TO _ :.......I ..................... ......................... 5"RCP I ;V , : :;:, .. .;:::::::::::::::: : .:::.: .} 91. WILL BE ALLOWED WITHOUT APPROVAL BY THE FACILITY DESIGNER. D.B.13134-2076 { :.. GAS FIREPIT .. JLL UIRr I ! I ' ::: FFE=414,a0. - = f` V~1C :_ 1 Y AND ALL QUANTITIES SHOWN OR IMPLIED ON THE PLANS ARE FOR ZONING- DC I �, I I ::::::;:t: ;::#: 9 /' 10. AN :� :II f: . - COSTANCE M. VANNO, :;:.::.I: a -a USE: RESIDENTIAL o :.::::f..: ...... - _ - ESTIMATION PURPOSES ONLY. i-- { : - �' KAI J. VANNOY IP V 41'I. ..::::::::::::.:.....:::............. i ` I :::::Ia: ::{::::?:;: w 9 . @� :::?::::::. :.:....:....... HIC PARKING SIGN � �, R3. D.8.13138, PG:2724 11. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT . ::.:•:::::::•::::: GRavE1 i w o } :', I: :::::.:{- ::::}::.:::: - �' CONDITIONS WARRANT OFF -SITE GRADING + (VAN ACCESS), Cg7 B.O.M.1992, PG.39 PROPERTIES. WHEN FIELD COND ]R,VE o 1 �: �' r f .. 0 _.- - ¢ GAS FIREPIT TYP. 4 SPACES ZONING-RMD PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. :;;::::: _ _ - ` , I a_ STAIRS TO Z_ , :..:.:::.... R3 INV-4I I 2 ; CD .....: �:k:; .;:; :::'::`•::::t:::::::::; ::.::::. INCF: ' R5 :. / USE: RESIDENTIAL GOOD LONGITUDINAL r . _I:.: V :: ::: �.:.::::.::::::.: f. - 9 \ 12. ALL ASPHALT EDGES SHALL BE SAW CUT TO PROVIDE A z I ¢ ',I ::;:; k:.: UPPER LEVEL € F.. R1fi 1 / }- ?:?:� :;`.::. J HID ASPHALT JOINT, MILL 1.5 FEET 1.5 INCHES DEEP MINIMUM TO PROVIDE A a _;;::;:::: a:; \ @ - . JII g' 1 :?h. SIDEWALK RAMP ........... INv 41t: (jj q 4 J I :; ;;:;,,;fit:: _:::.:.:.::.....• SID COLUMN, TYP. i J PAVEMENT LONGITUDINAL LAP JOIN FOR FINAL SURFACE LAYER. NO MILLING SHALL BE GRAVEI _L }, •::•::::::::.�::::.:::.:::.:::...:....•..........::.:::::::.:::::.:::::::....::. ...: ::. wl HANDRAIL R5 _ k ............................... :....::::.:.::: A-h'Utg?E ::::::::::: ::•...... }..... LANDING ' g 1 / LEFT FOR A PERIOD OF TIME GREATER THAN 48 HOURS BEFORE A STREET I5 c� ,-; :.:.:: t::.:::::::.::::::.:::::.::::: .._ I—,............................................t....................... CANOPY OUTLINE R15 a H1 [{'ARK{t+iG S1CN....... :.::::::.:::: ::::;ctSl ANii1S:::......:::::::;•:;•:::•::I:.::: ;:- R3; S@ TO BE PAVED OR RESURFACED. DRIVE I 2 I! :::...::::..::::....:.::..::::::..:::::::::::.......................................................... ;::..:. :::... :.::::::::::.....::.::::::.::::::.::::..:.:::•:::•.: ::> :: ............................... - "' �� / MSE RETAINING WALL 1 .......... w P I........................................................".................::::..::::::.:::::.:::::::::::::.::::::::.: :::::::::: r :.:::::.::.::::::.:::::::.:::: Q ::.:�W..: .�f �.I::......::::::.:.................................................... . _ .. .:::::::::.:::::::......................... , b, SUBMITTED TO ,...............:.........::::.........:.........:::............... \ 3. �. NO PARKING �-:•::::.:::::.::::::::.:::::::.....:::::::::::::::....::::::.:::::.... .::::: INV 41{1. 3 ..............................................-...................... 1 ANY SPECIALITY STREET SIGNS INCLUDING POSTS SHALL BE U I :::::::::.::: REVIEW AND APPROVAL PRIOR TO >l ::::: ....::..:.:::. ...:--•:-:••..:... :�:: _. _ _. - SIGN ( ) 1 THE TOWN OF FUQUQY VARINA FOR REV W r :::::::::�::.:::::.::...:.:: ..... : .: .................: .......:.....:...... -_- -- . _ _ `,. _ :::::..: ::.hIISEf E3~!!i ING WA 0:.- :•:::.:...:•::.:::.:........:.::.: .:::::.:::::::.::::::.:.- ::-•:- 0 l :: ::::: :::.:�:::::::::::.::::::.:::: .::::.::::::.:::::::.:: �:.::::.:::::.::::::.::...; .:::":::;:::.::; ::: o INSTALLATION. •.:::. ::::::::.::::.:::::::.::::::::.:::::.:::::.::::::::::::.:........ 15 .................................... / .... 1 \ :............................................................. . . BOLLARDS, TYP. C........................................................................................:.::::::.::::.::::: I BO - o...............................:: . :.':.::�.::::.:I:::::.::,'. . .... ... -.,.' .'"............*,,.......- T.-.. .. .. .. ..� �........................................................................................................................::::..::::. / 8 LANDSCAPE BUFFER - 14. ALL PUBLIC AND PRIVATE EASEMENTS SHALL BE RECORDED AS PART OF THE ....... 1 RANDOLPH GREENS L. C........................................... - R1.4 fk GREENBACK .......n..:::...:::.:::::•.,n..... .. ...:.:...............................................................................::::.::::::::. 6 TALL SCREEN WALL :::::::.;;•:: �,::; . .::•:: .::.�:::;•::<:•:::::::.:.......................... ..........................._........................................ - :.:...WCR.::.::•..:::.:::: L::•:::::.::_:::.:::.::::.::::.:::.::•..::::.:::::.::.::::.:::::::::•::::::.:::.::0 EASEMENTS BASED OF CENTER OF UTILITY KELVIN F. AKINS TRUSTEE � FINAL PLAT OF THE SUBDIVISION --:.:::.::.::::::.::::::.:::::.::.:::.:::::::.,::::::.::::::.:::::.:::::.:::...:::.:::::.::::...............1................. - D.B.1527$, PG 30 l HALL BE PER AS -BUILT LOCATIONS, -' ,:...:::::.:::::::a•:::::.::::::.:::::::........:::::.::::......:..:::.:.....::.::: ::: I B.O.M.1992. PG.39 OR PIPE S D.B.6846. PG.4 R :",.,."j::::::'',.,. .•.............................................:...:::::::.:::::..:::':::.". ::.':::::::.•.::::::.::.::.: -. I EWALK RAMP. } BENCH, TYP.. S D 1 0. d . o - 5 RESIDENTS'ACCESS ES 1 ::-.:-::-.:-:-::- ....... ........... ...._......It....... ...... HID CONC. ,. 0- 0 DUMPSTER PAD WITH SOLIb ZONING RMD 1 RESIDE CESS TO SHERRILL ROAD SHALL BE MAINTAINED AT ALL TIMZONING DC LL, I1 }l wl HANDRAIL PAVEMENT R4' /USE: RESIDENTIAL I I 11111, ENCLOSURE TO MATCH BUILDING 1 USE: RESIDENTIAL UNLESS OTHERWISE APPROVED BY THE ENGINEERING DEPARTMENT AND STAIRS F - , GRAIN STORAGE BINS _ WITH APPROPRIATE NOTICE TO THE IMPACTED PROPERTY OWNERS. 9' , . GONZALEZ ALEJANDRO CO �` . H/C PARKING SIGN CS-90-60 I C E R _ I TRUCK DOCK (48' ELEV. DIFF.) � VALENTINA GONZALEZ 16. ALL HVAC EQUIPMENT TO BE ROOF MOUNTED, MIN. SCREEN 1' ABOVE VAN ACC SS} NO PARKING SIGN 8 3a MODIFIED INu�a .91 I I ( ) I � 24 S07 .. .-I BOLLARD P. R4 5 S �' EQUIPMENT I I gD.B.5599, PG.453 PP l� 0 1 ,{ I CONC LOADING DOCK LID WHITE STOP BAR �,�S@ -4„�_ B4O.M.1993, PG.323 17. VEHICULAR GATES SHALL CONTAIN KNOX BOX ACCESS FOR FIRE 1j I GRAVEL '3; DRIVE ;� I ro INV408... 51 ---` a INV-407. - 7a"R P ti __ .. HEAUIN L. `,\ I `' cA L1-1 N.C.GGRID COORIDATES, NAD 83 = nccri N = 670727.115 E = 2061994.139 REVISIONS 1 7114/2020 TOFV COMMENTS 2 9/30/2020 TOFV COMMENTS 3 1211812020 TOFV COMMENTS/FINAL STATUS RELEASED FOR CONSTRUCTION DATE: FEBRUARY 3, 2020 HORZ, SCALE: 1" = 30' FILE NO. 2020-002 ORIG• SHEET SIZE: 24 x 36 I 9 m� �c � of <� a_ U LOM: N CONSULTANT urr ENGINEERING U��,� E N G 2 NF�N EST. © 10 �Ir 0, CARQ� NC LIC. NO. P-0799 . R35 Q HI TRIANGLE ZONING TRIANGLE IN . C. .., .: .. USE: RESIDENTIAL AT BACK OF CURB 0 ST-44 24 3:5'...:1 +0.. . " 14+00 14+29 . -0 z. MODIFIED f - .I - :.:._.. - �_ _ + _...._ _._._ I I . 30" STANDARD I CURB & GUTTER w _ W - -wx - - w. - E -- �- n,ailhvx Wr . AP? Oxlh kTE LOCATION 7F U14TER INiJE PEP, TOfV US yl __ T � -OHE ~OH ~- -- I 25' BC1BG L! I OHE _(SHE - - ~�� 40' EXISTING ROW OHE - '� _ Q \ INv-4C2,18 (001 H) pP ,G VEIL ma➢hox \ ,n /� o L'1 , HUMBERTO DEJESUS FLORES RE-ESTABLISH GRAVEL ALEJANDRO GONZALEZ ANA EUGENIA FLORES DRIVEWAY AFTER CULVERT JUANITA MARTINEZ GONZALEZ DB. 14039, PG.1299 DEMO (TYP• ALL DRIVEWAYS) DB. 6179, PG.40 BM. 2002, PG.1893 BM. 1993, PG.323 ZONING-RLD I ZONING-RLD USE: RESIDENTIAL USE: RESIDENTIAL CLIENT Aviator Brewing Company T (919) 552-01349 205 S. Fuquay Avenue F {919)552-2043 Fuquay-Varina,NG Z7526 209 Technology Park Lane Fuquay-Varina, NC 27526 919.567.2337 Contact: Mark Doble mark@aviatorbrew.com ALEJANDRO GONZALEZ FUOUAY-VA_ PINTA MATCHLINE 1C+ .. JUANITA MARTINEZ GONZALEAPPROVE ] FOR COMPLIANCE DB. 6179, PG.40 These plans have been approved for compliance with the Town BM. 1993, PG.323 Code of Crcinancos & Stanaard Specifications & Comlruction ZONING-RLD Detail = Iec #a st Cements conditions hereby incorporated USE: RESIDENTIAL by ref e Pn("� , t Signature Q Dote i- ZL--Zi BEFORE YOU DIG, CALL NORTH CAROLINA ONE CALL CENTER www.ncocc.org :ALE:1 IN = 30 FT 30' 60' SCALE IN FEET HORIZONTAL Projects shall be constructed according to the Standard Specifications and Details in effect at the time the project receives Town approval for construction. The Contractor must have a complete set of stamped plans and specifications on the jobsite any time work is being performed. Stamp shall be affixed to plans below: CONSTRUCTION DRAWINGS A VIA TOR BREWING COMPANY SITE LAYOUT C=06