HomeMy WebLinkAboutNC0025577_Inspection_20000427Cel'11.1/aYLi.1-12/l.) LPL, 5/3/0073(144' NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY FAYETTEVILLE REGIONAL OFFICE April 27, 2000 The Honorable George T. Paris Mayor, Town of Red Springs 217 South Main Street Red Springs, NC 28377' SUBJECT: Notice of Violation/ Compliance Evaluation Inspection Town of Red Springs WWTP NPDES Permit No. NC0025577 Robeson County Dear Mr. Paris: The subject inspection. was performed March 2, 2000 by several staff members representing various regional offices of the Division of Water Quality. Conducting the inspection were Belinda Henson and Don Register of the Fayetteville Regional Office, Pat Durrett of the Wilmington Regional Office, and Jenne Sowell and Ted Cashion of the Raleigh Regional Office. The cooperation of Leonard Green, Grade IV ORC, was appreciated. As stated in the NPDES permit Part II Section C.2.Proper Operation and Maintenance - "The permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the permittee to achieve compliance with the conditions of this permit." Based on the inspection of this facility the findings concluded violation of the NPDES permit with the above stated reason. Findings during the inspection included the following: 1. The 2.5 mgd treatment facility consists of a manual bar screen, mechanical bar screen, grit chamber, grit cyclone, dual oxidation ditches, dual clarifiers, cascade aeration, chlorine contact chamber, sludge digester, and 6 sludge drying beds. 2. The screen for the mechanical bar screen was broken on one side. This allows -large objects to pass through and potentially cause damage to equipment in the plant. This should be repaired to prevent problems. 3. Screenings were observed on the ground near the influent structure. These must be removed and properly disposed of immediately if not already done so. 4. There was a noticeable chlorine odor, and a large amounts of suds observed in the influent wastestream. This could cause treatment inefficiency and possible violations of the permit. We recommend the Town implement pretreatment requirements for Clayson Knitting to protect the Town's infrastructure, employees, and prevent permit violations. Mr. Green stated that pumps had been clogged with socks in the past. -continued- 225 GREEN STREET, SUITE 714 / SYSTEL BLD. FAYETTEVILLE, NORTH CAROLINA 28301-5043 PHONE 910-486-1541 FAX 910-486-0707 AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/1O% POST -CONSUMER PAPER 5. There were rags collected on the bars above the parshall flume. Valves at the influent structure appeared rusty and inoperable. The grit chamber was full of sand/grit and was not in service. Please ensure these areas are cleaned and made to operate as designed. 6. The railings and other fixtures at the plant need to be scraped and painted. Please be advised that failure to properly maintain the facility can lead to greater repair or replacement costs in the future. Also chronic failure to properly maintain the facility can be viewed as a violation of your NPDES permit. 7. As noted in the last inspection report dated August 31, 1999, the influent composite sampler refrigerator does not work. As discussed during the inspection, this must be repaired/replaced immediately. The temperature of the unit must be maintained at 0-4 Degrees C, without freezing. The sample tubing must also be replaced or cleaned. Influent samples may be collected at no greater than 20 minute intervals, with a minimum of 100 mis collected for each sampling event. Please ensure the sampler is programmed to comply with this requirement. 8. The concrete under the valve behind the flume was crumbling. Repairs must be made as soon as possible to prevent damage to the plant. 9. There was a valve located beside the grit chamber. It was unclear what the purpose of this valve was for. Please investigate and respond what this valve is for and where the piping leads to. 10. There were exposed wires at the bottom to the pole beside the grit chamber. Please ensure that this is inspected by an electrician and made safe. This is a potential safety hazard and should be addressed immediately. 11. The grit cyclone was rusted and appeared inoperable. Please ensure this unit is made operable. 12. The emergency generator was in operating condition. 13. There were several teeth missing from the rotors for the aeration basins. These must be repaired immediately to ensure that proper operation and treatment efficiency is maintained. 14. There were cracks on the outside walls on both aeration basins. As noted several times before we urge the Town to have a professional engineer evaluate these conditions for integrity periodically. 15. The clarifiers showed signs of sludge denitrifying (old sludge). The sludge blankets were 4.5 feet and 6 feet in the 2 clarifiers, both of which are 12 feet deep. It is recommended to have no more that a 4 feet blanket in these clarifiers to prevent solids. washout. The weirs on both clarifiers were uneven, causing solids to be carried over. The weirs must be leveled to prevent this from occurring, and jeopardizing permit compliance. Please have the weirs adjusted immediately and notify this office in writing within 10 business days of completion. 16. The 6 feet deep contact chamber had approximately 1 foot of sludge in the bottom. Sludge must be removed periodically from this unit to prevent carryover of solids in the effluent. Please record in your daily log each time the unit is cleaned. 17. Mr. Green stated that the effluent composite sampler was programmed to collect 250 milliliters of sample every 30 minutes. A letter has been sent to this facility dated March 21, 2000 requiring this facility to collect effluent samples flow proportionally by March 15, 2001. In the meantime proper sampling would be at least 100 milliliters every 20 minutes. -continued- 18. Mr. Green stated that the sludge digester was full. Currently, sludge is dried on 6 drying beds, then disposed of at the county landfill. The Town must consider an alternative sludge disposal. The Division does not consider landfill disposal an acceptable long term solution. Landfills are increasingly not accepting sludge from treatment plants, except for top cover. Please contact our office for guidance in this area. 19. The ORC logbook was reviewed and found to contain minimal information. As discussed with Mr. Green, the logbook must contain all daily activities (operation and maintenance) that occur at the plant. Please ensure detailed entries are made daily. 20. Laboratory calibration records were reviewed. As discussed, a minor amount of additional documentation needs to be recorded on the logs. 21. Mr. Green stated that the Town has 7 pump stations, and that none have telemetry. The Division recommends that the Town consider installing telemetry and if power outages have been a problem to install an emergency generator at each pump station to prevent sanitary sewer overflows, and the liability associated with such events. Please ensure that emergency telephone numbers are displayed at each pump station. 22. A cursory review of DMR data and laboratory data showed consistent reporting of results. 23. A review of long term monitoring data showed cyanide and mercury levels above the State's water quality standards for each of these parameters. The Town was required in the November 1998 inspection report to submit a study plan to isolate and remove these parameters. To date, this plan has not been submitted. You are directed to contact this office immediately upon receipt of this report to discuss this matter. 24. The Town has participated in a local Enterprise Zone/Enterprise Community package where 5 local communities may be eligible for federal funding directed toward possible regionalization of wastewater treatment and disposal. Please comment on the status of this project, and what efforts the Town is pursuing toward possible regionalization. 25. The current permit expired December 31, 1999. You are to operate under the conditions of this permit until the permit has been reissued. 26. The backup ORC is Gene Gooden, Grade II. 27. Please provide this office with an update of efforts undertaken to reduce inflow/infiltration (I/I) from the collection system. Include in your response the amount of resources expended in 1999, estimated amount of I/I removed in 1999, and what is planned for 2000 and 2001. 28. Test America and Burlington Research perform analyses for the Town. -continued- 29. A review of DMR data submitted since the last inspection, July 1999 through December 1999, showed the following: a. Several fecal coliform values of > (greater than) were reported. Please instruct your laboratory to set more dilutions in order to report an absolute number. b. pH values of 8.4 and 8.2 were reported on December 29 and 30, 1999 respectively. No explanation for these abnormally high values was offered. The industries in Town may have been conducting cleaning operations at this time of the year. We recommend the Town notify each industrial discharger of the potential problems associated with dumping substances down the sanitary sewer line that may occur at the treatment plant. c. Several low BOD and TSS influent values were reported. This is probably due to the chlorine bleach discharged to the plant, and/or an indication of the I/I problems of the Town. Both of these conditions may be detrimental to the treatment efficiency of the plant. d. Fecal coliform violations were noted for the weeks of November 9, November 16, and November 22, 1999. Comments on the DMR stated that the chlorine cylinder froze due to cold weather, and that the ORC had informed the Superintendent that a shelter needed to be built around the chlorine system earlier. Please comment as to what actions the Town has taken to prevent this condition from re -occurring. e. Fecal coliform violations were also reported for the week of October 18, 1999. DMR comments include that excess rain caused these violations. The Town has a flow paced chlorinator and should consider installing a dechlorination system, to lower the chlorine concentration discharged. 30. The following Notice of Violations (NOVs) have been sent to this facility for the parameters in the 1999 year period: January - Toxicity April - Fecal Coliform May - Fecal Coliform June - Fecal Coliform July - Toxicity August - Toxicity October - Fecal Coliform 31. The effluent at the time of the inspection had a slightly pink color, and contained some solids. No effluent samples were taken during the inspection. 32. A compliance evaluation analysis report for the period February 1999 through December 1999 revealed monthly fecal violations for September and November. In July the toxicity analysis was a violation for failure to pass. Please respond in writing to items 2-11, 13-15, 17, 18, 23, 24, 27, and 29 detailing actions taken to address these items. The Town has been notified previously concerning items 7, 13, 14, 15, and 23. Please submit this response on or before May 31, 2000 Violations of permit conditions are subject to enforcement action by the U.S. Environmental Protection Agency and this Division. Penalties of up to $25,000/day may be assessed for each violation of the permit. You are reminded that the Division's Technical Assistance and Certification Unit is available upon request to provide technical assistance to the Town at no cost. You may contact Dwight Lancaster, Supervisor of this Unit, at 919-733-0026. If you or your staff have questions concerning this report, please contact Ms. Henson at 910-486-1541. Paul E. Rawls Water Quality Regional Supervisor /bsh Enclosure cc: Wayne Horne, Town Manager Leonard Green, ORC Town of Red Springs WWTP Koonce, Noble and Associates Maurice Horsey, USEPA, Reg. IV DWQ NPDES Compliance Unit Dana Folley, DWQ Pretreatment Ted Cashion, DWQ Raleigh Regional Office Jenne Sowell, DWQ Raleigh Regional Office Pat Durrett, DWQ Wilmington Regional Office NPDES COMPLIANCE INSPECTION REPORT North Carolina Division of Water Quality Fayetteville Regional Office Section A. National Data System Coding Transaction Code: N NPDES NO. NC0025577 Date: 000302 Inspection Type: C Inspector: S Facility Type: 1 Reserved: Facility Evaluation Rating: 2 BI: N QA: N Reserved. Section B: Facility Data Name and Location of Facility Inspected: Town of Red Springs WWTP Entry Time: 10:00am Permit Effective Date: 950801 Exit Time/Date: 3:OOpm/000302 Permit Expiration Date: 991231 Name(s), Title(s) of On -Site Representative(s): Leonard Green (Certified Grade IV Operator) - "ORC" Phone Number(s): (910) 843-2654 Name, Title and Address of Responsible Official Mr. George Paris, Mayor 217 South Main Street Red Springs, NC 28377 Contacted: no Section C: Areas Evaluated During Inspection (S = Satisfactory, M = Marginal, U = Unsatisfactory, N = Not Evaluated, N/A = Not Applicable). Permit:: Records/Reports: S. Facility Site Review:'1VI Flow MeasurementS Laboratory: S Effluent/Receiving Waters:_S :Pretreatinent:, Compliance Schedule N/A Self -Monitoring Program: S Operation & MaintenanceIJ Sludge Disposal: S Other: INSPECTION REPORT UPDATE OPTION: TRX: 5IF KEY: NC0025577INSCEI 000302 SYSMSG: *** DATA ADDED SUCCESSFULLY *** PERMIT--- NC0025577 REG/COUNTY-- 06 ROBESON FACILITY-- RED SPRINGS (TOWN) - WWTP LOC--'RED SPRINGS INS TYPE CEI NEXT PLANNED INSPECTION INSPECTED BY: DATE: 000302 CT REPORT INSPECTION DMR RESPONSE RECEIVED DATE STATUS STATUS DUE DATE DATE 000427 NC C 000531 COMMENTS: INSPECTION WAS A JOINT EFFORT BY FRO AND RRO STAFF.