HomeMy WebLinkAboutWQ0040977_Application (FTSE)_20210920State of North Carolina
DWR
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: kM (40 q 7 (to be completed by DWR)
/M op
All items must be completed or the application will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Town of Fuquay-Varina. NC (company, municipality, 110A, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ® Municipal ❑ Other
3. Signature authority's name: Matthew B. Paling PE per 15A_NCAC 021 0106(b)
Title: Engineering Director NC Dept ofEnvironmentai Quality
4. Applicant's mailing address: 401 Old Honeycutt Road •+{
City: Fu uc� a� Varina State: NC Zip: 27626- SEP ? 0 LUG i
5. Applicant's contact information:
Phone number: (919) 753-1028 Email Address: MPoling(lfuquay-varina.org Raleigh Regional Office
II. PROJECT INFORMATION:
1. Project name: Powell Square Apartments
2. Application/Project status: ❑ Proposed (New Permit) ® Existing Pennit/Projeet
If a modification, provide the existing permit number. WQ0040977 and issued date: Aug. 13, 2019
If new construction but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Wake
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.6656 Longitude:-78.715906
5. Parcel ID (if applicable): 0689-47-0903 0689-36-6682 0689-37-8090 0689-46-1609
(or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
I. Professional Engineer: Mark Ashness. PE License Number: 18894
Finn: CE Group, Inc
Mailing address: 301 Glenwood Ave.. Suite 220
City: Raleigh State: NC Zip: 27603-
Phone number: (!!19) 367- MO Email Address: mark cegroupinc.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: Terrible Creek WWTP Permit Number: NCO00066516
Owner Name: Town of Fuquay-Varina
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: 8 inch
y� teun. Wide Collection S stem Permit Numbers if a )Iwable,): WQCS
Owner Name(s): Town of Fuauay-Varina
FORM: rTA 04- l6 Page I of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached'
[-]Yes ❑No ®N?A
2. If the Applicant is a Developer of lots to be sold, has a Developer's {.l rational Agreement (FORM: I)I V) been attached?
❑ Yes []No ®NIA
3. If the Applicant is a I fomc.JPro crt Owners' Association,. has an {) Lrational Agreement f .-ORM: 110A) been attached9
[-]Yes [-]No ®NIA
4. Origin of wastewater: (check all that apply):
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Conwiercial % Commercial
% Industrial (See 15A NCAC 02'1' .010.3{2031
,Is there a Pretreatment Program in effect? []Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T .01 14(f)? ❑ Yes ® No
➢ If Yes, Provide a cony of flow reduction approval letter
7. Summarize wastewater generated by project:
Establishment Type (see 02T.011411)
Daily Design Flow '•b
No. of Units
Flow
Residential Multi -Family - I & 2 Bedroom
240 gal/day
384
92,160 GPD
Clubhouse
10 gaVuser
t20
1,200 GPD
gaV
GPD
gaV
GPD
gall
GPD
gal/
GPD
Total
93,360 GPD
a See 15A NCAC 021;0114(b), (dl, te){l) and (c](2} for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table i 5A NCAC 02T.01 14] shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 93.360 GPD (per 15A NCAC 02,1..01 14)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number:
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04-16 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Scivers):
1. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8
774
DIP
8
2,259
SDR 35 PVC
8
367
C900 PVC
Section It & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
D Section III contains information related to minimum slopes for gravity sewer(s)
D Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations. Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -
3. Design flow of the pump station: millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDI4)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
6. Power reliability in accordance with I SA NCAC 02'C .U3051h1{ 1).
❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_
Required for all pump stations with an average daily (low greater than or equal to 15,000 gallons per day
Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
D It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage,
DORM: F-rA 04-16 .; Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)):
1. Does the project comply with all separations found in 15A NCAC 02T.0105(1) & ( ® Yes ❑ No
➢ 15A NCAC 02T.0305(t) contains minimum separations that shall be nrovided for sewer system%,
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below vertical
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines(horizontal - reclaimed over sewer
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water
100 feet
"Waters classified WS (except WS-1 or WS-V), 13, SA, ORW, HQW, or SB from normal
hij4i water or tide elevation and wetlands see item IX.2
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
➢ 13A.NCAC 02"1"_0305(g contains alternatives where separations in 02T.030 (t) cannot be achieved.
➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications wcbvakc
➢ If noncompliance with 02'r_0305(f) or (a), see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ® No ❑ N.'A
➢ See the Division's draft separation requirements for situations where separation cannot be meet
➢ No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15 A NCAC 0213 .0200? ® Yes ❑ No ❑ NSA
➢ This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project require coveragefauthorization under a 404 Nationwide or ® Yes [-]No
individual permits or 401 Water Quality Certifications?
➢ Information can be obtained from the 401 & Buffer Permitting 13ran0
5. Does project comply with 15A NCAC 02T.0105{cX6) (additional permitsrcertifications)? ® Yes ❑ No
Per 15A NCAC 02T.0105(c),6}, directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, e(c,).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per )..N_..CAC' 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
® Yes ❑ No ❑ NA
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority Rues shall be inspected by the permittee or its representative at least once every six-mantbs and inspections
documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04- l6 Page 4 of 5
KM
CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Mittn!tum Design Criteria for the Penpittipg of Pump Stations
and force Mains (latest version), and the Gravity Sewer Minimum Design Criteria latest version as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Allemative Design Request application (VADC 10-14) and supporting documents for
review. Approval of the request is re uired 11rior to submittal of the Fast Track A120lication and supporting documents.
2. Professional En ineer's Certification:
1, + __attest that this application for
'rofessional ngineer's name from Application Item Ill. 1.)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T .0106(b):
1, Matthew B. Poling
Engineering Director
(Signature Authority's name & title from Application Item I.3.)
attest that this application for
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated. I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature: Date: 09/02/2021
FORM: FTA 04- 16 Page 5 of 5
NC: l.)ept of hnvtronmcu&a..c•—•v
State of North Carolina
Raleigh Regional Office Department of Environmental Quality
Division of Water Resources
Division of Water Resource! Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: Town of Fu ua -Varina, NC
Project Name for which flow is being requested: Powell Square Apartments
More than are FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater jlols,.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: Terrible Creek WWTP
b. WWTP Facility Permit #: NC0066516
All flows are in MGD
c. WWTP facility's permitted flow 3.0
d. Estimated obligated flow not yet tributary to the WWTP 1,192
e. WWTP facility's actual avg. flow 1.152
f. Total flow for this specific request 0.0936
g. Total actual and obligated flows to the facility 2.44
h. Percent of permitted flow used 81.2%
11. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A) (B) (C) (D)=(B+C) (E)=(A-D)
Design Obligated,
Pump Average Daily Approx. Not Yet Total Current
Station Firm Flow** Current Avg. Tributary Flow Plus
(Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available
Number) MGD MGD MGD MGD Flow Capacity***
NW
1D--:---1 1.274 0.510 .261 .093 0.354 0.156
* The Firm Capacity of any pump station is defined as the maximum pumped flaw that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pf) not less than Z.S.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer):
Downstream Permit Number:
Page 1 of 6
FTSE 04-16
Ill. Certification Statement:
I Matthew Poling, P.E. Engineering certify to the best of my knowledge that the addition of
Director
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation of
the planned improvements identified in the planning assessment where applicable. This analysis
has been performed in accordance with local established policies and procedures using the best
available data. This certification applies to those items listed above in Sections I and II plus all
attached planning assessment addendums for which I am the responsible party. Signature of this
form indicates acceptance of this wastewater flow.
09 '02l2021
Signing Official Signature
Date
Page 2 of 6
FTSE 04-16
14C Dept of Environmental Quality
PROJECT NARRATIVE SE-P Z ® 2021
Raleigh Regional Office
The proposed Powell Square Apartments is located on a ,'- 26.88 acre tract within the
within the Town limits of Fuquay-Varina. It is located at the intersections of NC Hwy.
55 and Old Powell Road SR 1111. This is a proposed permit modification to increase the
original permit WQ#0040977 dated August 13, 2019 flow rate of 41,520 gpd to a new
permitted flow rate of 93,360 gpd per the table below. The original permit was for 168 1
and 2 bedroom units with clubhouse and outdoor swimming pool amenity area while the
modified permit will increase the total number of units to be 384 1 and 2 bedroom units.
The modification proposed is as follows:
Original Permit WQW040977
84 1-Bedroom Units @ 240 gpd = 20,160 gpd
84 2-Bedroom Units @ 240 gpd = 20,160 gpd
Clubhouse w/Pool — 1,200 gpd
Phase 1 Permitted Flow — 41,520 gpd
Permit Modification
108 1-Bedroom Units @ 240 gpd - - 25,920 gpd
108 2-Bedroom Units (a) 240 gpd 25,920 gpd
Phase 2 Modification add -- 51,840 gpd
Modified Overall Flow Rate 93,360 gpd
There are no other modifications required for this permit. The original permit did require
an 8" sanitary sewer High Priority aerial crossing over an existing unnamed tributary and
wetland area internal to the site which was identified in permit and plans previously
permitted.
CE GROUP
301 GLENWOOD AVE. STE 220
RILLEIGH,NC 27603
PHONE. 919-367.8790
www cegroupfnc.com
POWELL SQUARE APARTMENTS
FUQUAY-VARINA, NC
USGS OVERLAY EXHIBIT
FUQUAY-VARINA, NC 1993
(5
NORTH
1000, 0 1000,
SCALE: 1" = 1000'
NC'De tofEnvironmentalQuati CE GROUP
P tY
301 GLENWOOD AVENUE, SUITE 220
SEP 2 0 MI Phone: (9 9,) 367-8790
E-Mail: loefce4rouuinc. com
tf�t_!�L t1
TO: NCDENR — DWQ
Raleigh Regional Office
3800 Barrett Drive
Raleigh, NC 27609
ATTENTION: Permitting
),W OfflCy
' Transmittal
DATE: 9/20/21
PROJECT NO: 127-243
Powell Square Apartments
Fuquay-Varina
Permit Modification WQ#0040977
Quantity
Drawing No.
Description
2
1 copy/1 original
Fast Track Sewer System Extension Application
1
Copy
Project Narrative
1
Check
$480 Application Fee — Check #11360
1
Copy
Flow Tracking 1 Acceptance Form
1
Copy
USGS Overall Area Map
1
Copy
Vicinity Location Map
REMARKS Please let us know if you require any additional information.