HomeMy WebLinkAboutNc0085359_Compliance Evaluation Inspection_20211105ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Bart Farmer Union County 4600 Goldmine Rd Monroe, NC 28110 NORTH CAROLINA Environmental Quality November 5, 2021 SUBJECT: Compliance Inspection Report Twelve Mile Creek WRF NPDES WW Permit No. NC0085359 Union County Dear Mr. Farmer: The North Carolina Division of Water Resources conducted an inspection of the Twelve Mile Creek WRF on November 3, 2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0085359. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact Roberto Scheller with the Water Quality Regional Operations Section in the Mooresville Regional Office at 704-663-1699 or via email at roberto.scheller@ncdenr.gov. Sincerely, CFor DocuSigned by 91C2A007838943E... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Mooresville Regional Office - Enforcement File NPDES Compliance/Enforcement Unit NORTH CAROLINA Dep®rlmont of Environmental Onolit North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 IL I 21IIIIII NPDES yr/mo/day Inspection 3 I NC0085359 111 12I 21/11/03 I17 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 IIIIIIIIIII IIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 I 70I4 I 711 1 72 I N I 73I 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Twelve Mile Creek WWTP 8299 Kensington Dr Waxhaw NC 28173 Entry Time/Date 09:53AM 21/11/03 Permit Effective Date 21/07/01 Exit Time/Date 01:04PM 21/11/03 Permit Expiration Date 25/12/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Jonathan Brian Jordan/ORC/704-562-4542/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Bart Farmer,4600 Goldmine Rd Monroe NC 28110/Water Reclamation Facilities Superintendant/704-296-4227/7042897395 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Roberto Scheller of Inspector(s) Agency/Office/Phone and Fax Numbers DocuSigned by: Rj, S,ll„ DWR/MRO WQ/707-235-2204/ Date 11/5/2021 "-91C2A007838943E... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date 11/5/2021 W. Corey Basinger DWR/Division of Water Quality/704-235-2194/ DocuSigned by: For EPA Frm ( v 9-4-#144it5us editions are obsolete. 91C2A007838943E... Page# 1 31 NPDES yr/mo/day NC0085359 111 121 21 /11 /03 117 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The subject facility is permitted to discharge 7.5 MGD via Outfall 001 into Twelve Mile Creek, classified C waters in the Catawba River Basin. The curernt permit became effective on July 1, 2021 and expires on December 31, 2025. A 12-month compliance history was reviewed from September 2020 through August 2021. One violation was reported on 2/2021 (NOD-2021-LV-0070)for Flow. Wastewater Performance Report for fiscal year 2019-2020 was reviewed on Union County web site. 12 month average flow for calendar year 2020 was caculated at 5.4 MGD or 72% of permitted flow. Page# 2 Permit: NC0085359 Inspection Date: 11/03/2021 Owner - Facility: Twelve Mile Creek WWTP Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Permit became effective on July 1, 2021 and expires on December 31, 2025. Yes No NA NE ❑ ❑ • ❑ ▪ El El El • ❑ ❑ ❑ • ❑ ❑ ❑ Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • ❑ ❑ ❑ Is all required information readily available, complete and current? • ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? • ❑ El El Is the chain -of -custody complete? • El El El Dates, times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration ■ Dates of analysis • Name of person performing analyses • Transported COCs ■ Are DMRs complete: do they include all permit parameters? • El El ❑ Has the facility submitted its annual compliance report to users and DWQ? • El El El (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified • El ❑ ❑ operator on each shift? Is the ORC visitation log available and current? • El El El Is the ORC certified at grade equal to or higher than the facility classification? • El ❑ ❑ Is the backup operator certified at one grade less or greater than the facility • El El El classification? Is a copy of the current NPDES permit available on site? • ❑ El El Facility has copy of previous year's Annual Report on file for review? • El El El Comment: Wastewater Performance Report for Fiscal Year 2019-2020 was reviewed on the Union County web site. Bar Screens Yes No NA NE Page# 3 Permit: NC0085359 Inspection Date: 11/03/2021 Owner - Facility: Twelve Mile Creek WWTP Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE Type of bar screen a.Manual ❑ b.Mechanical • Are the bars adequately screening debris? • ❑ ❑ ❑ Is the screen free of excessive debris? • ❑ ❑ ❑ Is disposal of screening in compliance? • ❑ ❑ ❑ Is the unit in good condition? • ❑ ❑ ❑ Comment: Debris from barscreens appeared compacted and dry. Debris is placed in dumpster for disposal at landfill. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑ Is the wet well free of excessive grease? ❑ ❑ ❑ • Are all pumps present? • ❑ ❑ ❑ Are all pumps operable? ■ ❑ ❑ ❑ Are float controls operable? • ❑ ❑ ❑ Is SCADA telemetry available and operational? • ❑ ❑ ❑ Is audible and visual alarm available and operational? ❑ ❑ ❑ • Comment: Chemical Feed Yes No NA NE Is containment adequate? • ❑ ❑ ❑ Is storage adequate? ■ ❑ ❑ ❑ Are backup pumps available? • ❑ ❑ ❑ Is the site free of excessive leaking? • ❑ ❑ ❑ Comment: Alkalinity (lime) is added at influent pump station. Grit Removal Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Yes No NA NE ❑ ❑ ❑ Page# 4 Permit: NC0085359 Inspection Date: 11/03/2021 Owner - Facility: Twelve Mile Creek WWTP Inspection Type: Compliance Evaluation Grit Removal Comment: Flow Measurement - Influent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Flow meter is calibrated ever 6 months. Influent flow meter was last calibrated on 09/14/2021. Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: At time of inspection influent sampler was recorded at 3 degrees Celsius. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Nutrient Removal Yes No NA NE # Is total nitrogen removal required? ❑ ❑ • ❑ # Is total phosphorous removal required? • ❑ El El Type Chemical # Is chemical feed required to sustain process? • El El El Is nutrient removal process operating properly? • El El El Comment: NH3 as N removal is required to Monthly Average of 1.0 mg/I (Summer), 2.0 mg/i (Winter). Total Phosphorus removal is required to a Monthly Average of 41.70 Ibs/day and 12-Month Average of 20.85 Ibs/day. Facility has 4 treatment trains with an anoxic zone at the head of each train. Facility can also add Sodium Aluminate to aid in Phosphorous removal. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Page# 5 Permit: NC0085359 Inspection Date: 11/03/2021 Owner - Facility: Twelve Mile Creek WWTP Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ El • El Are the diffusers operational? • ❑ ❑ ❑ Is the foam the proper color for the treatment process? • ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? • ❑ ❑ ❑ Is the DO level acceptable? • ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/I) • ❑ ❑ ❑ Comment: Treatment train consist of anocix zone, high oxidation zone (DO 2.32 mg/I) and lower oxidation zone (DO 1.16 mg/I). Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? • ❑ ❑ ❑ Are weirs level? • ❑ ❑ ❑ Is the site free of weir blockage? • ❑ El ❑ Is the site free of evidence of short-circuiting? • ❑ ❑ ❑ Is scum removal adequate? • El ❑ ❑ Is the site free of excessive floating sludge? ■ El El El Is the drive unit operational? • El El El Is the return rate acceptable (low turbulence)? • ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? • El ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) El ❑ El • Comment: Effluent from clarifiers #2 and #6 was clear with few visible suspended solids. Pumps-RAS-WAS Are pumps in place? Are pumps operational? Are there adequate spare parts and supplies on site? Comment: Aerobic Digester Is the capacity adequate? Is the mixing adequate? Yes No NA NE • ❑ ❑ ❑ Yes No NA NE Page# 6 Permit: NC0085359 Inspection Date: 11/03/2021 Owner - Facility: Twelve Mile Creek WWTP Inspection Type: Compliance Evaluation Aerobic Digester Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: WAS is dewatered and transported to New Hill compost facility. Yes No NA NE • ❑ ❑ ❑ Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Cross flow Is the filter media present? • ❑ ❑ ❑ Is the filter surface free of clogging? • ❑ ❑ ❑ Is the filter free of growth? • ❑ El El Is the air scour operational? • ❑ ❑ ❑ Is the scouring acceptable? • ❑ ❑ ❑ Is the clear well free of excessive solids and filter media? ❑ ❑ • ❑ Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? ❑ ❑ ❑ • Are UV bulbs clean? • ❑ ❑ ❑ Is UV intensity adequate? ■ ❑ ❑ ❑ Is transmittance at or above designed level? • ❑ ❑ ❑ Is there a backup system on site? • ❑ ❑ ❑ Is effluent clear and free of solids? • ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • ❑ ❑ ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? ■ El ❑ ❑ Is the tubing clean? • El El El # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • El El El representative)? Page# 7 Permit: NC0085359 Inspection Date: 11/03/2021 Owner - Facility: Twelve Mile Creek WWTP Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE Comment: At time of inspection effluent sample was recorded at 3 degrees Celsius. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Comment: Flow meter is calibrated every 6 months by CITI. Last meter calibration was performed on 9/14/2021. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ El ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Page# 8