Loading...
HomeMy WebLinkAbout20210034 Ver 2_File 2 - 2nd Submittal to DWR Complete Package Final_20211103 Carpenter,Kristi From:Lennon, Andre <alennon@cecinc.com> Sent:Thursday, April 01, 2021 2:40 PM To:Chapman, Amy; Hood, Donna Cc:Thomas, Kevin; Shawn Pennell; Brown, David W CIV USARMY CESAW (USA); Carpenter,Kristi; Mizzi, Janet; Hamstead, Byron A; Degnan, Jesse; Krystynka.B.Stygar@usace.army.mil; Johnson, Matt; Walters, Shad Subject:RE: City of Hickory: Startown / Robinson Road Connectors ID # 20210034 Attachments:File 2 - 2nd Submittal to DWR Complete Package Final.pdf Ms. Hood, nd 2 of two (2) emails. Let us know if you need anything else. Thanks. Andre L. Lennon, P.E. | Senior Project Manager Civil & Environmental Consultants, Inc. 3701 Arco Corporate Drive, Suite 400, Charlotte, NC 28273 direct 980.260.2045 office 980.237.0373 mobile 704.574.0066 www.cecinc.com From: Lennon, Andre Sent: Wednesday, March 31, 2021 3:15 PM To: Chapman, Amy <amy.chapman@ncdenr.gov>; Hood, Donna <donna.hood@ncdenr.gov> Cc: Thomas, Kevin <kthomas@cecinc.com>; Shawn Pennell <spennell@hickorync.gov>; Brown, David W CIV USARMY CESAW (USA) <David.W.Brown@usace.army.mil>; Carpenter,Kristi <kristilynn.carpenter@ncdenr.gov>; Mizzi, Janet <janet_mizzi@fws.gov>; Hamstead, Byron A <byron_hamstead@fws.gov>; Degnan, Jesse <jdegnan@cecinc.com>; Krystynka.B.Stygar@usace.army.mil; Johnson, Matt <mrjohnson@cecinc.com>; Walters, Shad <swalters@cecinc.com> Subject: RE: City of Hickory: Startown / Robinson Road Connectors ID # 20210034 Good afternoon Ms. Hood, Please see our resubmittal for the subject project for the City of Hickory Startown/Robinson Road Connectors Project. The file is 16MB so we have prepared a link to the compiled package at the link below: http://downloads.cecinc.com/303-168 If you don’t mind please acknowledge receipt for our records to satisfy the resubmittal requirements for DWR ID # 20210034. The package includes our Cover letter with comment responses along with supporting exhibits and design documents. We appreciate your review of the project documents and let us know if you require any additional information or have any questions. Thanks. Andre Andre L. Lennon, P.E. | Senior Project Manager Civil & Environmental Consultants, Inc. 1 3701 Arco Corporate Drive, Suite 400, Charlotte, NC 28273 direct 980.260.2045 office 980.237.0373 mobile 704.574.0066 www.cecinc.com From: Walters, Shad <swalters@cecinc.com> Sent: Wednesday, March 31, 2021 1:41 PM To: Chapman, Amy <amy.chapman@ncdenr.gov>; Hood, Donna <donna.hood@ncdenr.gov> Cc: Thomas, Kevin <kthomas@cecinc.com>; Shawn Pennell <spennell@hickorync.gov>; Brown, David W CIV USARMY CESAW (USA) <David.W.Brown@usace.army.mil>; Carpenter,Kristi <kristilynn.carpenter@ncdenr.gov>; Mizzi, Janet <janet_mizzi@fws.gov>; Hamstead, Byron A <byron_hamstead@fws.gov>; Degnan, Jesse <jdegnan@cecinc.com>; Lennon, Andre <alennon@cecinc.com> Subject: RE: \[External\] City of Hickory: Startown / Robinson Road Connectors ID # 20210034 Ms. Chapman: Thank you for your consideration on the timing for the re-submittal. As requested, we performed two site visits to confirm the presence of the dwarf-heartleaf with the last site visit being last week….. which we found numerous clusters that impacted our previously prepared plans. We are working diligently today to complete the resubmittal to show the avoidance of the plants - which we anticipate should be out shortly to you guys. We apologize for any inconvenience - let us know if you guys need any additional information to support the City of Hickory’s application. Shad W. Walters, P.E. | Vice President Civil & Environmental Consultants, Inc. 3701 Arco Corporate Drive, Suite 400, Charlotte, NC 28273 direct 980.260.2127 office 980.237.0373 mobile 704.430.8537 www.cecinc.com From: Chapman, Amy <amy.chapman@ncdenr.gov> Sent: Wednesday, March 31, 2021 1:17 PM To: Hood, Donna <donna.hood@ncdenr.gov> Cc: Walters, Shad <swalters@cecinc.com>; Thomas, Kevin <kthomas@cecinc.com>; Shawn Pennell <spennell@hickorync.gov>; Brown, David W CIV USARMY CESAW (USA) <David.W.Brown@usace.army.mil>; Carpenter,Kristi <kristilynn.carpenter@ncdenr.gov>; Mizzi, Janet <janet_mizzi@fws.gov>; Hamstead, Byron A <byron_hamstead@fws.gov> Subject: RE: \[External\] City of Hickory: Startown / Robinson Road Connectors ID # 20210034 15A NCAC 2H.0507 gives the Director of DWR the ability to deny any 401 application that does not meet our requirements. st I know the question Mr. Thomas wanting the full 60 days to respond. We can give him until 5pm tomorrow (April 1 ) since Friday is a holiday and his 60 days is up on a weekend when we are not open. 2 From: Hood, Donna <donna.hood@ncdenr.gov> Sent: Wednesday, March 31, 2021 11:22 AM To: Chapman, Amy <amy.chapman@ncdenr.gov> Cc: Walters, Shad <swalters@cecinc.com>; Thomas, Kevin <kthomas@cecinc.com>; Shawn Pennell <spennell@hickorync.gov>; Brown, David W CIV USARMY CESAW (USA) <David.W.Brown@usace.army.mil>; Carpenter,Kristi <kristilynn.carpenter@ncdenr.gov>; Mizzi, Janet <janet_mizzi@fws.gov>; Hamstead, Byron A <byron_hamstead@fws.gov> Subject: RE: \[External\] City of Hickory: Startown / Robinson Road Connectors ID # 20210034 Hi Amy, Mr. Thomas is questioning the DWR ability to return an incomplete application. Also, the endangered Hexasylis naniflora species has now been found on this site after the plant review was performed at the correct time of year. The Corps has not been informed of this finding except by an email I sent about 30 minutes ago. I have also copied the US Fish and Wildlife Service. As the 401 permit writer, I advise that both Federal agencies should weigh in on this finding prior to resubmittal for DWR approval. Thank you for any response you may have. Regards, Donna Hood From: Thomas, Kevin <kthomas@cecinc.com> Sent: Wednesday, March 31, 2021 11:02 AM To: Hood, Donna <donna.hood@ncdenr.gov> Cc: Walters, Shad <swalters@cecinc.com> Subject: \[External\] City of Hickory: Startown / Robinson Road Connectors ID # 20210034 CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Ms. Hood. Here is Shads email. Thanks, Kevin Thomas, PWS & LSS (NC, SC & FL) / Senior Project Manager Civil & Environmental Consultants, Inc. 3701 Arco Corporate Drive · Suite 400 · Charlotte, NC 28273 Toll-Free: 855-859-9932 · Direct: 980-260-2035 · Fax: 980-237-0372 Mobile: 410-259-4745 · http://www.cecinc.com Senior Leadership · Integrated Services · Personal Business Relationships This electronic communication and any attachments are intended solely for the use of the person or entity to which it is addressed, and may contain information that is confidential, privileged and exempt from disclosure under applicable law, including copyright law. If you are not the intended recipient of this message, you are prohibited from disclosing, reproducing, distributing, disseminating or otherwise using this transmission. Please promptly notify the sender by reply electronic communication and immediately delete this message from your system. 3 BRIDGE STUDY ELLER DRIVE CONNECTOR over MUDDY CREEK Prepared For: CITY of HICKORY NORTH CAROLINA Prepared By: CIVIL & ENVIRONMENTAL CONSULTANTS, INC. CHARLOTTE, NC CEC Project 303-168 MARCH 2O21 \`IlllllAlllrll/1/ D' S _ SEAL 42781 _ .N " / 4uu..N ///1►rllllll►11,` NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C-3035 ' 'i. AW Civil & Environmental Consultants, Inc. Charlotte 3701 Arco Corporate Drive,Suite 400 Charlotte, NC 28273 I p:980-237-0373 f.980-237-0372 1 www.cecinc.com TABLE OF CONTENTS PROJECTLOCATION MAP ....................................................................................................2 APPENDICES: PROJECT DESCRIPTION.........................................................................................................2 APPENDIX A: ESTIMATED STRUCTURE COST TABLES............................................6 DESIGN CRITERIA....................................................................................................................3 APPENDIX B• BRIDGE PLANS 8 . ............................................................................................ MATERIAL SPECIFICATIONS ..............................................................................................3 APPENDIX C• DECK DRAINAGE CALCULATIONS 13 . .................................................... COMPUTER SOFTWARE.........................................................................................................4 CONSTRUCTION CONSIDERATIONS ..................................................................................4 MISCELLANEOUS STRUCTURAL REQUIREMENTS ......................................................4 PROPOSED BRIDGE ELEMENTS ..........................................................................................5 ESTIMATED STRUCTURE COST...........................................................................................5 RECOMMENDED ALTERNATIVE.........................................................................................5 Civil & Environmental Consultants, Inc. -1- Eller Drive Connector over Muddy Creek March 2021 PROJECT DESCRIPTION PROJECT LOCATION MAP A. Introduction - The proposed bridge is located on a proposed new roadway connecting Eller Drive and Short Road over ,,Oer Si Fisher Sj Muddy Creek in Hickory, North Carolina. The proposed structure will carry two lanes of traffic, one east ' bound and one west bound. The design speed is 25 MPH. Two alternatives have been evaluated for this Bride Study. The alternatives are as follows: i + ` Alternative 1: { ' - Simple span prestressed concrete box beam bridge with eleven (11) 39 prestressed concrete box r � t beams spaced at 3 0 .The proposed bridge length is 76 0 from center to center of abutment bearings - ,� and a total of 81'-3 1/8" out to out. The bridge length was established based on criteria set by the site geometry and hydraulic calculations. The out to out bridge width for this alternative is 33 -0 . This alternative was evaluated using a conventional stub abutment. „,3 Alternative 2: Simple span steel rolled beam bridge with four (4) 36" steel rolled beams spaced at 9'-0". The proposed bridge length is 76'-0" from center to center of abutment bearings and a total of 79'-1 7/8" out to out. The bridge length was established based on criteria set by the site geometry and hydraulic PROJECT calculations. The out to out bridge width for this alternative is 32'-10". This alternative was evaluated LOCATION using integral abutments. IL B. Alignment and Grade The horizontal alignment of the proposed structure is located on a tangent with a bearing of S 49' 22' 24"W. The construction centerline is skewed approximately 18 degrees with Muddy Creek. jrs"�-.Pw ThOm\pson% B I ack's Au to Col I i8 i on Kamp DF �} The proposed structure is locate entirely on a+3.68% grade vertical tangent. The profile grade line is applied ' at the centerline of the lanes. C. Typical Section and Superelevation VICINITY MAP The typical section of the proposed structure will consist of two (2) 10'-0" lanes and 2'-4 1/2" shoulders with a 6" curb on the right and a 5'- 0" sidewalk on the left lane. The structure will utilize three bar metal railing for the barrier. The entire bridge is located on a tangent alignment;therefore,there is no superelevation. The bridge has a 1/4" per foot normal crowned slope. Civil & Environmental Consultants, Inc. -2- Eller Drive Connector over Muddy Creek March 2021 DESIGN CRITERIA Concrete Structures From: 20°F to 105°F Design and plan submission will conform to the Design Criteria provided in this section. ii. Sizing Bearings and Joints Steel Structures From: 10 OF to 110°F A. Specifications Concrete Structures From: 20°F to 105°F 5. Seismic: 1. AASHTO "EKED Bridge Design Specifications", 9th Edition, 2020. The design shall be in accordance with AASHTO LRFD Bridge Design Specifications, Earthquake 2. State of North Carolina Department of Transportation Structures Management Unit Structure Effects. The bridge is located in Seismic Zone 1 according to Figure 2-1 of the NCDOT SDM. Design Manual (September 2020) 6. Fatigue: 3. NCDOT Structure Design Unit Standard Drawings, 2012. Fatigue design shall be in accordance with AASHTO LRFD Specifications 4. NCDOT Standard Specifications for Roads and Structures, January 2018. MATERIAL SPECIFICATIONS B. Design Method A. Structural Steel: Alternatives will be designed according to the AASHTO Load and Resistance Factor Design Method(LRFD). Bearings AASHTO M270 Grade 50 C. Design Loading Superstructure AASHTO M270 Grade 50 1. Dead Loads: B. Concrete: a) Reinforced Normal Weight Concrete 150 lbs/ft3 b) Future Bituminous Wearing Surface 301bs/ft2 All concrete properties shall be in accordance with the specified 28-day compressive strength (f c) c) Permanent Metal Deck Forms 3 lbs/ft2 and concrete class as follows: d) Three Bar Metal Rail 25 lbs/ft 1. Cast-in-place deck(Class AA) 4,500 psi, n=7 2. Live Loads: 2. Footings and Abutments (Class A) 3,000 psi, n=9 3. Approach Slab (Class AA) 4,500 psi, n=7 The design Live Load for the LRFD method is HL-93, which will be distributed using AASHTO LRFD Specifications. C. Concrete Cover: 3. Wind Loads: A monolithic concrete bridge deck with epoxy-coated bars shall be used. The clear distance between the reinforcing steel and the face of the concrete shall be: Design Wind Loads shall be per AASHTO LRFD Specifications. 1. Top of Slab 2.50 inches 4. Thermal Forces: 2. Bottom of Slab 1.25 inches 3. Bottom of Footing 3 inches a) The assumed normal fabrication and erection temperature is 60'F 4. All other locations 2 inches b) Thermal Coefficient of Expansion i. Steel Structures 6.5 x I V per OF ii. Concrete Structures 6.0 x 10-6 per OF c) Seasonal Variation i. Structural Design Steel Structures From: 10 OF to 110°F Civil & Environmental Consultants, Inc. -3- Eller Drive Connector over Muddy Creek March 2021 D. Reinforcing Steel: CONSTRUCTION CONSIDERATIONS Reinforcing steel shall conform to the requirements of AASHTO M31 Grade 60. A. Clearance Requirements All barrier rail,parapet, sidewalk, deck,bent caps,pile caps and footings reinforcement shall be epoxy There are no horizontal or vertical clearance requirements. coated. B. Maintenance of Traffic and Staged Construction E. Fasteners (Diaphragms and Splices): There are no maintenance of traffic issues associated with the proposed stream crossing. All fasteners shall be 7/8-inch diameter high strength bolts conforming to AASHTO M 164 Type 3 unless otherwise specified. C. Constructability F. Shear Connectors: Access for construction equipment and materials to the site will not be an issue for the proposed stream crossing. 7/8-inch diameter steel stud shear connectors shall be used for the steel girder alternative. The shear connectors shall be attached in the field after erection of the girders and installation of the deck forms, MISCELLANEOUS STRUCTURAL REQUIREMENTS however, some shear studs may be attached in the shop to support the contractors fall protection system. A. Deck Drainage G. Anchor Bolts: For the alternatives under consideration, scuppers/drain assemblies are not anticipated. Inlets will be placed before the bridge to intercept roadway surface discharge. If required, the deck drainage system will be Anchor bolts shall be in accordance with AASHTO M111. designed in accordance with the Manual "Design of Bridge Deck Drainage" dated May 1993 (FHWA Hydraulic Engineering Circular no. 21, publication no. FHWA-SA-92-010). The rainfall design frequency H. Steel H-Piles: shall be based on a 10-year recurrence. All steel piling shall conform to AASHTO M183. B. Bearings COMPUTER SOFTWARE Elastomeric bearing pads will be used for both alternatives. The following computer programs will be available to be used in the analysis and design: C. Environmental, Utilities, and Aesthetics • HEC-RAS There are no utility requirements for this structure. • MDX by MDX Software (steel girder analysis and design) • LEAP Bridge Concrete (prestressed concrete box beam design) There are no special aesthetic requirements for this site. • AutoCAD Civil 3D 2020 • Microsoft Excel HYDRAULIC STUDY A hydraulic analysis was performed in conjunction with the bridge study to determine the impact of the proposed bridge on the water surface elevation of Muddy Creek. Hydraulic analyses were performed for the existing condition and the proposed alternatives using HEC-RAS. The 100-yr discharge was evaluated and shows only a .01 foot increase of the base flood elevation. Civil & Environmental Consultants, Inc. -4- Eller Drive Connector over Muddy Creek March 2021 PROPOSED BRIDGE ELEMENTS A. Superstructure 1. Alternative 1 superstructure consists of a flexible pavement overlay supported on eleven 39 inch prestressed concrete box beams spaced at 3'-0"with no overhang. 2. Alternative 2 superstructure consists of an 8.5"concrete deck supported on four 36"steel rolled beams spaced at 9'-0", with overhangs of 2'-11". B. Abutments 1. Alternative 1 will use stub abutments with cantilevered turn-back U-wings supported by steel vertical and brace piles. 2. Alternative 2 will use integral abutments with cantilevered turn-back U-wings supported on steel vertical piles. ESTIMATED STRUCTURE COST A summary of the estimated construction costs for each alternative is presented below. Detailed cost estimates are included in Appendix B. Alternative Total Structure Cost Alternative 1 $1,088,556.65 Alternative 2 $788,536.60 RECOMMENDED ALTERNATIVE We recommend Alternative 2 for advancement through the final design process. Civil & Environmental Consultants, Inc. -5- Eller Drive Connector over Muddy Creek March 2021 APPENDIX A ESTIMATED STRUCTURE COST TABLES Civil & Environmental Consultants, Inc. _6 Eller Drive Connector over Muddy Creek March 2021 ELLER DRIVE CONNECTOR OVER MUDDY CREEK BRIDGE STUDY CONSTRUCTION COST ESTIMATES ALTERNATIVE 1 ALTERNATIVE 2 SIMPLE SPAN W/39" PRESTRESSED CONCRETE BOX BEAMS ON STEM SIMPLE SPAN W/36" STEEL ROLLED ABUTMENTS BEAMS ON INTEGRAL ABUTMENTS ITEM NUMBER DESCRIPTION UNIT UNIT COST QUANTITY COST QUANTITY COST 8112730000-N PDA TESTING EA $3,700.00 1 $3,700.00 1 $3,700.00 8121000000-N UNCLASSIFIED STRUCTURE EXCAVATION LS $4,000.00 1 $4,000.00 1 $4,000.00 8147000000-E REINFORCED CONCRETE DECK SLAB SF $38.50 - - 2,410 $92,785.00 8161000000-E GROOVING BRIDGE FLOORS SF $0.50 - - 2,410 $1,205.00 8182000000-E CLASS A CONCRETE (BRIDGE) CY $1,100.00 120 $132,000.00 80 $88,000.00 8210000000-N BRIDGE APPROACH SLABS LS $200,000.00 1 $200,000.00 1 $200,000.00 8224000000-E EPDXY COATED REINFORCING STEEL (BRIDGE) LB $1.50 14,400 $21,600.00 9,600 $14,400.00 8280000000-E APPROXIMATE LBS STRUCTURAL STEEL LB $2.00 - - 46,200 $92,400.00 8328200000-E PILE DRIVING EQUIPMENT SETUP FOR HP12X53 STEEL PILES EA $440.00 28 $12,320.00 14 $6,160.00 8364000000-E HP12X53 STEEL PILES LF $85.00 2,300 $195,500.00 1,150 $97,750.00 8482000000-E THREE BAR METAL RAIL LF $295.00 163 $48,085.00 160 $47,200.00 8608000000-E RIP RAP CLASS II (2'-0" THICK) TON $47.40 260 $12,324.00 260 $12,324.00 8622000000-E GEOTEXTILE FOR DRAINAGE SY $4.00 440 $1,760.00 440 $1,760.00 8657000000-N ELASTOMERIC BEARINGS LS - 1 $33,000.00 1 $24,000.00 8753200000-E 3'-0" X 3'-3" PRESTRESSED CONC BOX BEAMS LF $329.00 858 $282,282.00 - - SUBTOTAL $946,571.00 $685,684.00 15% ENGINEERING AND CONTINGENCY $141,985.65 $102,852.60 TOTAL $1,088,556.65 $788,536.60 Civil & Environmental Consultants, Inc. Eller Drive Connecter over Muddy Creek -7- March 2021 APPENDIX B BRIDGE PLANS Civil & Environmental Consultants, Inc. _g Eller Drive Connector over Muddy Creek March 2021 PROJECT REFERENCE NO. SHEET NO. 303-168 7 R/W SHEET NO. ROADWAY DESIGN ENGINEER �4 PROPOSED 4"0 FRENCH DRAIN WITH CLASS II RIPRAP APRON CLEANOUTS IN BOTTOM OF LEVEL SPREADER ID,p SFONE SIZE=61N FRENCH DRAIN INV: 870.75 MIN.DEPTH = 13.5IN CO PROPOSED LEVEL SPREADER PROPOSED 40 LF OF 4"0 SCH 40 I BOTTOM ELEVATION=873.50 Pvc® 1.00%FROM FRENCH DRAIN RPRAP BERM ELEVATION=875.50 DOCUMENT NOT CONSIDERED FINAL To DAYLIGHT I RIPRAP BERM D50 STONE SIZE= 12IN UNLESS ALL SIGNATURES COMPLETED FLARED END ,-,W,_ SECTION(FES) W.(187-a73.50 200 Civil&Environmental Consultants,Inc. ihllil l co ro,A 0WRo Lm.E."Cz 11 PRELIMINARY 7 / I co I RIP-RAP DISSIPATOR NOT FOR CONSTRUCTION / CURB IN (CI) / L 14FT / \ RIM-879.94 , 201 / I W= 16FT / \���:W.IN(18"NW)-874.25 Dzp STONE SIZE=61N - / INV.OUT(18"SE)=874.06 / I J MIN.DEPTH= 121N / / � I HYDRAULIC INFORMAITON EX. OPENING = N/A 1° PRO. OPENING = 592 SF / �0 65 81'-3A"OUT TO OUT 76'-0"q BRG.TO @ BRG. ' 6 / Q25 = 600 GFS 15'-o" e 865 CFS APPROACH SLAB 1 " r -- �100 = APPROACH SLAB AT a 'S'T 72'-10j"CLEAR SPnN_- m ' _ _ EX. 100-YR W.S.E. = 872.00' 5 _ PRO. 100-YR W.S.E. = 872.01' z y' Z tt u0-i ABBREVIATION LEGEND W FILL FACE® C o o w p END BENT 1, j N I ® / L \ - BRG.=BEARING r S 49'22'24"W 00 _ _ 3}0 / 422'24'W n ow / a+n0 68 / \ _ 5+j / / B.S.E. = BEARING SEAT ELEVATION z CL-y 4 0 \ APPR.=APPROACH 1 / / 0 5 0' V l m -n \ / ABUT. =ABUTMENT SEND FACE® `� \ _� - rL=CENTERLINE J o RILL BENT 2 0 / _ _ \\ \ W.S.E.-WATER SURFACE ELEVATION Fl \ �- _ - _ -- -- --1 TYP.-TYPICAL p _x— n-- w U I _ _ - - -cam ELEV. =ELEVATION / 0 �p�CURB INLET(CI) 202 \ \\ -E E --� FIX.-FIXED^O 0� �0 RIM-879.94 \ I - EXP.=EXPANSION m� m �.I INV.OUT(18"SE)=874.50\ \ I _ ------------ LEGEND EX. MINOR CONTOUR EX. MAJOR CONTOUR RIPRAP EDGE OF ELK CREEK EX.OVERHEAD WIRE BRIDGE ALTERNATIVE#1 39"PRESTRESSED CONCRETE BOX BEAMS WITH STEM ABUTMENTS PLAN @ SCALE: 1"= 20' P 900 900 1'-3j"0/0 BRIDGE LiNGTH 890 890 AF PR.S APPR.LAB 9"PRESTRESS 880 PROFILE E ONCR BOX BEAM 880 8 870 1J¢1 SLOP DBE 1 870 a 711N SLOPE NO FM-ALE STA. +08.2 AL TO B/F EL 1172.15 860 B/F E 868.9 J 860 1'-0"NORMAL — TO CAP(TYP.) 0 1 EX STING 850 G UND 850 PRO ECTION (TYP) 840 840 830 830 2+50 2+60 2+70 2+80 2+90 3+00 3+10 3+20 3+30 3+40 3+50 3+60 3+70 3+80 3+90 4+00 4+10 4+20 4+30 4+40 4+50 BRIDGE ALTERNATIVE#1 39"PRESTRESSED CONCRETE BOX BEAMS WITH STEM ABUTMENTS SECTION ALONG-Y- SCALE: 1"= 20' PROJECT REFERENCE NO. SHEET NO. 303-168 8 R/W SHEET NO. ROADWAY DESIGN ENGINEER �A PROPOSED 4"0 FRENCH DRAIN WITH CLASS II RIPRAP APRON CLEANOUTS IN BOTTOM OF LEVEL SPREADER 2� ID.STONE SIZE= 61N FRENCH DRAIN INV: 870.75 MIN.DEPTH= 13.5IN 0 CO PROPOSED LEVEL SPREADER PROPOSED 40 LF OF 4"0 SCH 40 I BOTTOM ELEVATION=873.50 PVC® 1.00%FROM FRENCH DRAIN RIPRAP BERM ELEVATION=875.50 TO DAYLIGHT I RIPRAP BERM D50 STONE SIZE= 121N DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED FLARED END SEC10N(FES) / INV.(18")=e73.5 0 200 CO Civil&Environmental Consultants,Inc. "ro,AA0000Ao " Lo E 2111 CO � smzmm�"eao- s / -✓' /%�'�7 RIP-RAP DISSIPATOR / CURB INLET(p / L= 14FT P R E L I M I N A R Y \ RIM-879.94,i,Li 2D1 / I W= 16FT NOT FOR CONSTRUCTION / \_--INV.IN(18"NW)=874.25 D5o STONE SIZE=61N / INV.OUT(18"SE)=874.06 / I J MIN.DEPTH= 121N �IIIII' HYDRAULIC INFORMAITON i� i/� �I II�I ��� EX. OPENING = N/A t/x 779'-1�"OUT TO OUT o �� ' i I I I I PRO. OPENING = 592 SF 6'-D"(i BRG.TO rL BRG./ �;�— e" i �i i i i �I 15'-D^ Q25 = 600 CFS APPROACH SLAB APPROA H SLAB % i i� - j j j QIOO = 865 CFS + 72'-10j"CLEAR SPAN- - g ; — -- EX. 100—YR W.S.E. = 872.00' a PRO. 100—YR W.S.E. = 872.01' o 0 FILL FACE O i o � / �• \ I II ABBREVIATION LEGEND END BENT 1 N F of w = ® \ _ z jS 49'22'24"W 2+00 � /3}0 / 4 22'24"W N o 7 g / 4+00 g8 \ 5,19 / BRG.=BEARING W -- - - - - - �i -• 2. - a I O \ \ B.S.E. BEARING SEAT ELEVATION !Y I I I z / CE Y- I \ \ �. I 1n g APPR.=APPROACH -= N ABUT.-ABUTMENT \FILL FACE® rL-CENTERLINE \ END BENT 2 - w W.S.E.=WATER SURFACE ELEVATION T1P. =TYPICAL ELEV.=ELEVATION / h CURB INLET(CI) \202 \ \\ / �_ --��___---- _ RIM=879.94 \ \ / _-__ _- FIX.. -FIXED INV.OUT(18"3E)-874.50\\ \\ ��\ �\ I I� /� ———— EXP.-EXPANSION LEGEND x IX.MINOR CONTOUR IX.MAJOR CONTOUR RIPRAP EDGE OF ELK CREEK f— �0051 I / EX.OVERHEAD WIRE BRIDGE ALTERNATIVE#2 36"STEEL ROLLED BEAMS WITH INTEGRAL ABUTMENTS PLAN P SCALE: 1"= 20' P 900 900 $ 9'-1a"0/0 BRIDGE LE14GTH 890 890 AF PR.S APPR.LAB 880 P )FILE G E 880 L 870 1Yz:1 LOPE D BEN 1 870 STA. 09.31 NORM L TO C P B/7 EL 8 2.15 36"R LLED 860 F EL 868.97 BEAM I a 860 '-0"h DIRMAL o 1 XISDNG ei a 850 TO CAP ') ROUND 850 F UNDAT N 840 P TEC'R N 840 830 1 830 2+50 2+60 2+70 2+80 2+90 3+00 3+10 3+20 3+30 3+40 3+50 3+60 3+70 3+80 3+90 4+00 4+10 4+20 4+30 4+40 4+50 BRIDGE ALTERNATIVE#2 36"STEEL ROLLED BEAMS WITH INTEGRAL ABUTMENTS SECTION ALONG-Y- SCALE: 1"= 20' PROJECT REFERENCE NO. SHEET NO. 303-168 10 R/W SHEET NO. ROADWAY DESIGN ENGINEER 33'-0"OUT TO OUT 6" DOCUMENT NOT CONSIDERED FINAL 1. 1•-31• 5'-0. 14•_ • 14_ CURB 1•_31• 1„ UNLESS ALL SIGNATURES COMPLETED SIDEWALK ,/,A AZ THREE BAR METAL RAIL(TYP.) Civil&Environmental Consultants,Inc. FLEXIBLE PAVMENT OVERLAY P R E L I M I N A R Y 2.Ox NOT FOR CONSTRUCTION FOOT }'/FOOT 11 El El El 0 El El El El 11 Z 0 11 -39"PRESTRESSED CONCRETE BOX BEAM O 3'-0"SPA.=33'-0" to LL ALTERNATIVE 1-PRESTRESSED CONCRETE BOX BEAMS TYPICAL SECTION SCALE. 1/2"= 1'-0" j S 32'-10"OUT TO OUT &'F 7 6"1'-32" 5'-0" 12'-44" 12'-4,1" CURB �2 SIDEWALK � THREE BAR METAL RAIL(TYP.) o g 2.OR 4 FOOT }"/FOOT Q r g d 8 i 2'-11" 4-36"STEEL ROLLED BEAMS O 9'-0"SPA.=27'-0" 2'-11" ALTERNATIVE 2-STEEL ROLLED BEAMS TYPICAL SECTION SCALE: 1/2"= 1'-0" PROJECT REFERENCE NO. SHEET NO. 303-168 11 R/W SHEET NO. ROADWAY DESIGN ENGINEER 'S o �w w PROFILE GRADE a 10, 6, PROFILE GRADE DOCUMENT NOT CONSIDERED FINAL c UNLESS ALL SIGNATURES COMPLETED CL BRGS. �w �� m ,iii Civil&Environmental 3 o qco`Consultants,Inc.�E Ne��'a N <oo N asp . r--------------------------------------------------- -------- PRELIMINARY NOT FOR CONSTRUCTION I I ; I FILL FACE i i FlLL FACE i 1+j"FORMED OPENING i i i __________ _________ __ to 0 ELASTOMERIC BEARING CONST.JZT. 36"STEEL ROLLED BEAM to q BRGS.& PILES W 3.-PRESTRESSED cc CONCRETE BOX BEAM ELASTOMERIC R n BEARING PAD 0 p ii it N }} g ii I G w w W. u u ii ii e u u 3 u n CONIC.COLLAR- 12%%'k LI 2'-0"0 CONIC. ii i�i •I (TyP') \ COLLAR(TYP.) it STEEL PILE(TYP.) STEEL PILE(TYP.) P rL VERTICAL PILES rL BRACE PILES � I � Q 1-3" 1-6" 1-3" 1-fi" 1-6" g d _ 4'-0" 3'-0" p� d 8 i ALTERNATIVE 1-STEM ALTERNATIVE 2-INTEGRAL ABUTMENT TYPICAL SECTION ABUTMENT TYPICAL SECTION SCALE: 1"= 1'-0" SCALE: 1"= 1'-0" APPENDIX C DECK DRAINAGE CALCULATIONS Civil & Environmental Consultants, Inc. -13- Eller Drive Connector over Muddy Creek March 2021 F�r> Civil & Environmental Consultants, Inc. PROJECT Hickory Bridge Study PROJECT NO. 303-168 PAGE 14 PREPARED BY HTC DATE 3/1/2021 CHECKED BY GSL DATE 3/1/2021 SCUPPER CALCULATIONS Required Scupper Spacing 24393.E [LI.67 5L.5 T2.671 L = L J = 141.6ft. Cn i wp Sx 0.02 SL 0.0368 T 4.375 ft. Wp 24.75 ft. n 0.016 C 0.9 i 6.94 in/hr 10-yr Occurrence Lb 76 ft. Proposed Bridge Length Scuppers are not required. Distance of proposed bridge length is less than the required scupper spacing. \\svr-charlotte\projects\300-000\303-168\-Ca I cu I ati o ns\303168-Scu p pe r.xl sx See Sheet ] A For I n d e x o f Sheets m STATE PROJECT REFERENCE NO. SNOT SHEETS See Sheet 1 B For Conventional Symbols N.C. 303-16$ 1 7 0- ROB SON ROAD / SHORT ROAD CONNECTORS STATE PROD. NO. F. A. PROJ. NO. DESCRIPTION p z PE, R/ W, UTIL Hwy 70 SE C TY OF H CKORY CATAWBA COUNTY 2 1 �o DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED SITE 1 FOR PERMITTING ONLY LOCATION : HICKORY , NORTH CARO LINA NOT FOR CONSTRUCTION Date: 3/25/2021 By: ALL SITE 2 Cn z <I TYPE OF WORK : GRADING PAVING & DRAINAGE a o - WETLANII AND SURFACE WAT � . R IMPAC , ,-) PERMIT ZN � M 7- � o a 0 V C N TY MAP NOT TO SCALE o � y = —Y— ALIGNMENT I BEGIN —L— ALIGNMENT Q0 SITE 1 STA: 0+00Of 00 � � BRIDGE CROSSING Y UNNAMED TRIBUTARY TO � O V— _ MUDDY CREEK S R END —L— ALIGNMENT Z Z 12/ / STA: 17+65 m m Ui 5 o I Of SITE 2 CMP CULVERT o CROSSING v a J I 0 C ,U N I O �i J THERE IS NO CONTROL OF ACCESS ON THIS PROJECT o THIS PROJECT IS NOT WITHIN ANY MUNICIPAL BOUNDARIES. CLEARING ON THIS PROJECT SHALL BE PERFORMED TO THE LIMITS ESTABLISHED BY METHOD II 3 a m GRAPHIC SCALES DESIGN DATA PROJECT LENGTH o SCALE IN FEET ADT 2020 = XX,XXX LENGTH ROADWAY TIP PROJECT XXXX -L- =XXXX MI Civil & Environmental 0 400 soo XX,/VV`z^ZX LENGTH ROADWAY TIP PROJECT XXXXX -Y- =XXXXX MI Consultants, Inc. ADT2040 — 3701 ARCO CORPORATE DRIVE SUITE 400 CHARLOTTE,NC 28273 980-237-0373-800-365-2324 ww.CeMc.com T = XX%* 2018 STANDARD SPECIFICATIONS 3 -L- V = 30 MPH ° Q -Y- V = 35 MPH ANDRE LENNON, P.E. I TTST X% + DUALS X% PROJECT ENGINEER * � RIGHT OF WAY DATE: o NCDOT CONTACT: MATTHEW JOHNSON FUNCTION CLASS: LOCAL LETTING DATE: PROJECT DESIGNER NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C3035 PROJECT REFERENCE NO. SHEET NO. 303-168 1 A R/W SHEET NO. os 2 Zoe � ,��► �1�i i`.Atti►p�,���i INDEX OF SHEETS GENERAL NOTES: 2018 SPECIFICATIONS EFFECTIVE: 01 - 1 6-2018 •�� SEAL SHEET NUMBER SHEET = 0337 6 REVISED: 40 , 1 TITLE SHEET GRADE LINE: /it � 1 A INDEX OF SHEETS, GENERAL NOTES AND LIST OF STANDARD DRAWINGS GRADING AND SURFACING: NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C3035 1 B CONVENTIONAL SYMBOLS L.vCUMENT NOT CONSIDERED FIN.,._ THE GRADE LINES SHOWN DENOTE THE FINISHED ELEVATION OF THE PROPOSED UNLESS ALL SIGNATURES COMPLETED 2A PAVEMENT SCHEDULE AND TYPICAL SECTIONS SURFACING AT GRADE POINTS SHOWN ON THE TYPICAL SECTIONS. GRADE LINES MAY BE 4 —L— PLAN VIEW ADJUSTED AT THEIR BEGINNING AND ENDING AND AT STRUCTURES AS DIRECTED BY THE ENGINEER IN ORDER TO SECURE A PROPER TIE—IN. Civil & Environmental 5 —L— PROFILE VIEW Consultants, Inc. 6 —Y— PLAN/PROFILE VIEW BRIDGE ALTERNATIVE # 1 CLEARING. 3701 ARCO CORPORATE237-03DRIVE SUITE65 CHARLOTTE,NC 28273 980. 37-0373.800-3 -2324 www.cecinacom 7 —Y— PLAN/PROFILE VIEW BRIDGE ALTERNATIVE #2 CLEARING ON THIS PROJECT SHALL BE PERFORMED TO THE LIMITS ESTABLISHED BY FOR PERMITTING ONLY 8A BRIDGE TYPICAL SECTIONS METHOD II. NOT FOR CONSTRUCTION Date: 3/25/2021 By: ALL 8B ABUTMENT TYPICAL DETAILS SUPERELEVATION: EC- 1 A — EC- 1 D EROSION CONTROL DETAILS ALL CURVES ON THIS PROJECT SHALL BE SUPERELEVATED IN ACCORDANCE WITH EC-2 SOIL STABILIZATION SUMMARY SHEET STD. NO. 225.04 USING THE RATE OF SUPERELEVATION AND RUNOFF SHOWN ON THE PLANS. EC-2A SOIL STABILIZATION TIMELINE SUPERELEVATION IS TO BE REVOLVED ABOUT THE GRADE POINTS SHOWN ON THE TYPICAL SECTIONS. EC-3 —L— CLEARING AND GRUBBING EROSION CONTROL PLAN EC-4 —L— EROSION CONTROL SIDE ROADS: UC- 1 —L— UTILITY PLAN THE CONTRACTOR WILL BE REQUIRED TO DO ALL NECESSARY WORK TO PROVIDE SUITABLE CONNECTIONS WITH ALL ROADS, STREETS, AND DRIVES ENTERING THIS PROJECT. THIS WORK WILL BE PAID FOR AT THE CONTRACT UNIT PRICE FOR THE PARTICULAR ITEMS INVOLVED. EFF. 01 — 1 6-2018 SUBSURFACE DRAINS: REV. 2018 ROADWAY ENGLISH STANDARD DRAWINGS SUBSURFACE DRAINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH STD. NO. 815.02 AT LOCATIONS DIRECTED BY THE ENGINEER. The following Roadway Standards as appear in "Roadway Standard Drawings" Highway Design Branch N. C. Department of Transportation — Raleigh, N. C., Dated January, 2018 are applicable to this project STREET TURNOUT: and by reference hereby are considered a part of these plans: STREET RETURNS SHALL BE CONSTRUCTED IN ACCORDANCE WITH STD. NO. 848.04 USING STD.NO. TITLE THE RADII NOTED ON PLANS. DIVISION 2 — EARTHWORK 200.02 Method of Clearing — Method II UTILITIES: 225.04 Method of Obtaining Superelevation — Two Lane Pavement 225.06 Method of Grading Sight Distance at Intersections UTILITY OWNERS ON THIS PROJECT ARE: DIVISION 3 — PIPE CULVERTS PIEDMONT NATURAL GAS (PNG) — FUTURE GAS SERVICES, 300.01 Method of Pipe Installation DIVISION 8 — INCIDENTALS CITY OF HICKORY PUBLIC SERVICES — FUTURE WATER & SEWER SERVICE, 815.02 Subsurface Drain DUKE ENERGY — FUTURE ELECTRICAL SERVICE, 838.01 Concrete Endwall for Single and Double Pipe Culverts — 15" thru 48" Pipe 90 Skew CENTURYLINK — FUTURE FIBER OPTIC SERVICE. 838. 11 Brick Endwall for Single and Double Pipe Culverts — 15" thru 48" Pipe 90 Skew ANY RELOCATION OF EXISTING UTILITIES WILL BE ACCOMPLISHED BY OTHERS, EXCEPT 838.80 Precast Endwalls — 12" thru 72" Pipe 90 Skew 840.00 Concrete Base Pad for Drainage Structures AS SHOWN ON THE PLANS. 840.01 Brick Catch Basin — 12" thru 54" Pipe CURB RAMPS 840.02 Concrete Catch Basin — 12" thru 54" Pipe N 840.03 Frame, Grates and Hood — for Use on Standard Catch Basin CURB RAMPS ARE SHOWN ON THE PLANS AT APPROXIMATE LOCATIONS. 840.45 Precast Drainage Structure CONSTRUCT ALL CURB RAMPS ACCORDANCE WITH STD 848.05 and/or 848.06. 840.51 Brick Manhole — 12" thru 36" Pipe a 840.52 Precast Manhole — 4', 5' and 6' Diameter 840.53 Precast Manhole with Masonry Base — 12" thru 42" Pipe 840.54 Manhole Frame and Cover 840.66 Drainage Structure Steps 846.01 Concrete Curb, Gutter and Curb & Gutter 848.01 Concrete Sidewalk 848.04 Street Turnout U 848.05 Curb Ramp — Proposed Curb 8c Gutter 0 876.02 Guide for Rip Rap at Pipe Outlets q, 3 O O U 12 O O O O PROJECT REFERENCE NO. SHEET NO. STATE OF NORTH CAROL � NA D � V � S � ON OF H � GHWAYS 303-168 1 B 9 FOR PERMITTING ONLY NOT FOR CONSTRUCTION CONVENTIONAL PLAN SHEET SYMBOLS Date:3/25/2021 By: ALL SCUNSDIES AND PROPERTY: Note: Not to Scale *S. UN. Subsurface Utility Engineering WATER: State Line _____ RAILROADS: Standard GaugeHed Water Manhole OW County Line CSx TRANSP°RTATI°N ge Water Meter RR Signal Milepost 0 Woods Line Township Line MILEPOST 35 Water Valve City Line Switch Orchard SWITCH Water Hydrant � RR Abandoned � � � � Vineyard vineyard y Reservation Line U/G Water Line LOS B (S.U.E*) W RR Dismantled EXISTING STRUCTURES: Property Line U/G Water Line LOS C (S.U.E*) - -W- - MAJOR: Existing Iron Pin F° U/G Water Line LOS D (S.U.E*) W RIGHT OF WAY H PROJECT CONTROL : Bridge, Tunnel or Box Culvert CONC AEG Water Computed Property Corner Above Ground Water Line El Secondary Horiz and Vert Control Point ♦ Bridge Wing Wall, Head Wall and End Wall CONC WW Property Monument ECM Sequence Number 2 Primary Horiz Control Point 0 MINOR: TV: Parcel / Se q 0 TV Pedestal Primary Horiz and Vert Control Point ' Head and End Wall CONS HW Existing Fence Line TV Tower 0 Exist Permanent Easment Pin and Cap - 0 Pipe Culvert Proposed Woven Wire Fence � Footbridge >--- ----� N U/G TV Cable Hand Hole -- Proposed Chain Link Fence New Permanent Easement Pin and Cap - g - - Proposed Barbed Wire Fence � Vertical Benchmark m Drainage Box: Catch Basin, DI or JB ❑CB U/G TV Cable LOS B (S.U.E. ) TV- - - U/G TV Cable LOS C (S.U.E. ) - -TV- - Existin Wetland Boundary - - _ _ _ _ _ Existing Right of Way Marker 0 Paved Ditch Gutter g y -WLB U/G TV Cable LOS D (S.U.E. ) TV Existing Right of Way Line Storm Sewer Manhole O Proposed Wetland Boundary WEB U/G Fiber Optic Cable LOS B (S.U.E.*) - - - -TV FO- - - New Right of Way Line Storm Sewer Existing Endangered Animal Boundary FAB s U/G Fiber Optic Cable LOS C (S.U.E.*) — —TV FO— Existing Endangered Plant Boundary EPB New Right of Way Line with Pin and Cap U TI LI TIES:ESo U/G Fiber Optic Cable LOS D (S.U.E.*) TV FO Existing Historic Property Boundary "PB New Right of Way Line with POWER: Concrete or Granite R/W Marker GAS: Known Contamination Area: Soil S •� - Existing Power Pole S � _ Gas Valve 0 Potential Contamination Area. Soil � � New Control of Access Line with Concrete C/A Marker Proposed Power Pole b :. W .:_ Gas Meter Known Contamination Area: Water ExistingControl of Access c Existing Joint Use Pole - - - - - - Potential Contamination Area: Water ? W ? - U/G Gas Line LOS B (S.U.E.*) -O- New Control of Access Proposed Joint Use Pole * O Contaminated Site: Known or Potential ? U/G Gas Line LOS C (S.U.E. ) ExistingEasement Line E Power Manhole © * ° U/G Gas Line LOS D (S.U.E. ) SUI LDI NCS AND OTHER CULTURE.- New Temporary Construction Easement E Power Line Tower Above Ground Gas Line A/C Gas Gas Pump Vent or U/G Tank Cap 0 New Temporary Drainage Easement -TDE Power Transformer Sign 0 U/G Power Cable Hand Hole SANITARY SEWER: New Permanent Drainage Easement PDE Well W H-Frame Pole Sanitary Sewer Manhole New Permanent Drainage / Utility Easement DUE - - Sanitary Sewer Cleanout + Small Mine New Permanent Unlit Easement P E U/G Power Line LOS B (S.U.E.*) - - 0 y � U/G Sanitary Sewer Line ss Foundation 0 U/G Power Line LOS C (S.U.E.*) - New Temporary Utility Easement TUE Air Sanitary Sewer Area Outline New Aerial Utility Easement auE U/G Power Line LOS D (S.U.E.*) P Above Ground Sanitary Sewer -: Cemetery fi SS Forced Main Line LOS B (S.U.E.*) FSS - TELEPHONE: SS Forced Main Line LOS C (S.U.E.*) - -Fss- - N Building ROADS AND RELATED EEA TUBES: N School Existing Telephone Pole SS Forced Main Line LOS D (S.U.E. ) Fss Existing Edge of Pavement Proposed Telephone Pole -0- Church Existing Curb — MISCELLANEOUS: Telephone Manhole O Dam Proposed Slope Stakes Cut - - - - p p Telephone Pedestal HYDROLOGY: n Utility Pole 2 Pro osed Slo e Stakes Fill - F - - - p p - - Utility Pole with Base El Stream or Body of Water Telephone Cell Tower m Proposed Curb Ramp " Utility Located Object 0 Hydro, Pool or Reservoir - U/G Telephone Cable Hand Hole 0 Existing Metal Guardrail U/G Telephone Cable LOS B (S.U.E.*) -T Utility Traffic Signal Box ❑S Jurisdictional Stream - - - - - - - JS Proposed Guardrail T T T T Utility Unknown U/G Line LOS B (S.U.E.*) ?UTL Buffer Zone 1 Bz 1 U/G Telephone Cable LOS C (S.U.E.*) T Existing Cable Guiderail T U/G Tank; Water, Gas, Oil 0 Buffer Zone 2 Bz2 n n n n U/G Telephone Cable LOS D (S.U.E.*) Proposed Cable Guiderail Flow Arrow U/G Telephone Conduit LOS B (S.U.E.*) - —TC— - - Underground Storage Tank, Approx. Loc. SST Equality Symbol * A/G Tank; Water, Gas, Oil Disappearing Stream U/G Telephone Conduit LOS C (S.U.E. ) TC 0 . .Spring Pavement RemovalU/G Telephone Conduit LOS D (SUE.*) T Geoenvironmental Boring 1/ECF TA TIONo U/G Test Hole LOS A (S.U.E.*) Wetland U/G Fiber Optics Cable LOS B (S.U.E.*) e Single Tree 0 * Abandoned According to Utility Records AATUR Proposed Lateral, Tail, Head Ditch U/G Fiber Optics Cable LOS C (S.U.E. ) T FLOW False Sump Single Shrub O End of Information a U/G Fiber Optics Cable LOS D (S.U.E.*) T E.O.I. 0 a a PROJECT REFERENCE NO. SHEET NO. 303-168 2A PAVEMENT SCHEDULE R/W SHEET NO. 03 . 2 Zo2 C PROP. APPROX. 2.5" ASPHALT CONCRETE SURFACE COURSE, TYPE S9.5C, �►�� �CAR ��ii� AT AN AVERAGE RATE OF 168 LBS. PER SQ. YD. IN EACH OF TWO LAYERS. .•S81 .-iy%�� ;4 SEAL E 8" COMPACTED AGGREGATE BASE COURSE, COMPACTED TO 100% OF MAXIMUM 0337 6 ZZ DENSITY. ��.�,'.• ,• � ,�\�: R PROP. 2'-6" CURB AND GUTTER NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C3035 S 4" CONCRETE SIDEWALK DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED [1A A Civil & Environmental Consultants, Inc. 3701 ARCO CORPORATE DRIVE• SUITE 400 • CHARLOTTE,NC 28273 980-237-0373.800-365-2324 —ceanc.com FOR PERMITTING ONLY NOT FOR CONSTRUCTION Date: 3/25/2021 By: ALL a �i 0 N a J I O C -�C .0 Z I O O N LU N > cc �i J h W q� Q -L- & -Y- 50.00' STREET RIGHT—OF—WAY i 12.50' SHOULDER 12.50' 12.50' 12.50' h 5.00' W 10.00 10.00' CONCRETE W 2.50' LANE LANE 2.50' 3.00' SIDEWALK 4.50' a N a a 2 MAX 2 MAX c .o U c 1 GRADE 1 E C POINT FOOT FOOT FOOT " / FOOT / 2 MAX 2 MAX= a —III I I IL IIIIIII I—III 1 I ILI � �LIFF-11-LI Eil I 1 :1 11 11 IEii I Fil E 11-11 ' ' NOT TO SCALE U 6 O w q) 3 TYPICAL SECTION o -L- ALIGNMENT p -Y-ALIGNMENT v I i 0 0 0 0 a PROJECT REFERENCE NO. SHEET NO. SCALE IN FEET 303-168 4 0 20 40 R/W SHEET NO. Z Zo2 0�'5 DENOTES IMPACTS IN CA,/����/ ' S RC �� S SURFACE WATER `&:0. $ �DE�y��� ;4F SEAL r-; _ 0337 6 LENGTH=195.19' D RADIUS=500.00' A=022°22'00.01 " ��► I \ (A o CHORD DIRECTION=S 29°26'35.74" E � CHORD LENGTH=193.95' NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND 0 PI STA=8+27.31 SURVEYORS LICENSE NO. C3035 (A 3 65 TANGENT LENGTH=98.85' I DOCUMENT NOT CONSIDERED FINIAL. S�P.Ig23 1� UNLESS ALL SIGNATURES COMPLETED �.. 131�2a0OgCURB INLET (CI) 0111 RIM=OUT (1 111AIV �� - �� FtGP INV. OUT (18"W)=887.13 1 2Ar LE Civil & Environmental Consultants, Inc. 3701 ARCO CORPORATE DRIVE• SUITE 400 - CHARLOTTE,NC 28273 980.237-0373.800-365-2324 w-cecin-cm FOR PERMITTING ONLY CURB INLET (CI) � NOT FOR CONSTRUCTION RM89 O110 Date: 21 L INV. IN (18"E)=886.89 INV. OUT (18"SE)=886.69 Ohs \ O - <O0 1O k 00 0112 CURB INLET (CI) RIM=884.73 INV. OUT (18"SW)=880.44 O� fn ZO ,���� \ s1C-1 / /�� STREAM I II cn / II TOP OF I BANK I I WSTREAM a CURB INLET (CI) ,� i I BOTTOM OF RIM=884.73 0109 ,� / i BANK INV. IN (18"NE)=880.20 \ / " S, / CURB INLET (CI) N INV. IN (18 NW)=880.20 6'� 0113 I i \RIM=876.99 CLASS II RIP-RAP � i INV. OUT (18"SE)=880.00 D50 STONE SIZE = 301N INV. OUT (18"SW)=872.00 MIN. DEPTH = 68IN 0107 CURB INLET (CI) DOUBLE CMP BARREL ti RIM=873.60 9S`�cA ,,X00 INV 862.00 �� INV. OUT (18"S)=866.49 Q CURB INLET (CI) - 00 �Gv N 00 0106 RIM=886.00 a CD N�`! INV. OUT (18"S)=882.24 0 r- LENGTH=348.37 ti � � 0�+00 o RADIUS=275.00' ' a_N 00 A=072°34'55.49" /� Q .. CHORD DIRECTION=S 54°33'03.47" E `y Rv z wR w w w w w w z ww CHORD LENGTH=325.54 \� W PI STA=1 1 +25.59 TANGENT LENGTH=201 .94' 12 2'-6" C&G N a ce J I I 13+00 - - _ - - 3 CURB INLET (CI) 0 v CO N _ _ - N89' 09' 28.79"E -� a RIM=876.99 0108 ,Q `Q^per ^ I I 231.428 00 o ry 14+00 N 15+00 INV. IN (18"NE)=871.76V l " / 145 LF OF PROPOSED r / in - - - - INV. IN (18 NW)=871.50 / ,�ti -N - - - - _ - 18 RCP ° INV. OUT (18"E)=871.30 / , PERMANENT STREAM / _ - - - _ _ - - - - - 200 LF a IMPACTS i 18 RCP 2'-6" C&G " 18 RCP / DOUBLE CMP BARREL 69 LF 5' SIDEWALK 131 LF INV 859.00 DOUBLE CMP BARREL rev R R R R R W W W W 2 / INV 860.00 / N�A� W If IfW W W RB INLET (CI) CLASS II RIP-RAP / 0101 CURB INLET (CI) V_(��RIUN w =886.00 ° D50 STONE SIZE = 301N RIM=873.60 CURB INLET (CI) INV. IN (18"E)=882.00 MIN. DEPTH = 681N ,��T , INV. IN (18�N)=866.25 0102 RIM=875.68" INV. IN (18"N)=882.00 a F� INV. IN (18 E)=864.98 INV. IN (18 E)=870.04 a STREAM Fp i INV. OUT (18"W)=881.80 TOP OF Fib INV. IN (18"W)=867.80 INV. OUT (18"W)=869.84 o BANK INV. OUT (24"SW)=864.78 LENGTH=134.78' v m UNNAMED i ' RADIUS=700.00' `O TRIBUTARY TO i 0100 CONCRETE FLARED END SECTION A=011°01 '53.93" MUDDY CREEK / INV. (24 )=864.50 CHORD DIRECTION=N 83°38'31 .82" E STREAM co I BOTTOM OF CHORD LENGTH=134.57' o o BANK I / RIP-RAP DISSIPATOR I PI STA=15+71 .04 11'1 W = 1 1FT TANGENT LENGTH=67.60 CLASS II RIP-RAPT) ( �/ // / D STONE SIZE = 61N D50 STONE SIZE = 61N ���� / / MIN. DEPTH I 12IN MIN. DEPTH = 13.5 IN �; ��� / / / / / CO CLASS II RIPRAP APRON INV = 861.35 � D50 STONE SIZE = 6IN MIN. DEPTH = 13.5IN 0 PROPOSED LEVEL SPREADER BOTTOM ELEVATION = 864.50 RIPRAP BERM ELEVATION = 866.50 RIPRAP BERM D50 STONE SIZE = 121N PROPOSED 40 LF OF 4"0 SCH 40 PVC D01.00%AYLIGHT FROM FRENCH DRAIN TO DAYLIGHT PROPOSED 4"0 FRENCH DRAIN WITH / CLEANOUTS IN BOTTOM OF LEVEL SPREADER /C9FRENCH DRAIN INV: 861.75 / FOR -L- PROFILES, SEE SHEET N0. 5 PROJECT REFERENCE NO. SHEET NO. 303-168 5 R/W SHEET NO. ZCA 846 Zo2 �����••RCE ��i ;4 SEAL 0337p ��l I NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C3035 I DOCUMENT NOT CONSIDERED FINAII.� UNLESS ALL SIGNATURES COMPLETED rj,. AA. ' AVA. Civil & Environmental Consultants, Inc. 3701 ARCO CORPORATE DRIVE• SUITE 400 • CHARLOTTE,NC 28273 980-237-0373.800-365-2324 www.cecinc.com FOR PERMITTING ONLY NOT FOR CONSTRUCTION Date: 3/25/2021 By: ALL HORIZONTAL SCALE IN FEET 0 20 40 VERTICAL SCALE IN FEET Mimi 0 5 10 0 900 N Y Y 900 N z z N J 05 9 p = o 0 N O O O L j 895 d_0000 895 0 - N 00(0 - O a 890 a M 00 CD N°i 890 t18" RCP �00 >� 'rn N 0000 e INV=887\ o00 w Q 0�0000 N >M 00 0 N wQ w 3' MIN. COVER 0 J a_ 0} O ' 885 18" RCP i s N N o 885 N INV=880.32 I N =� 8"0 PUBLIC I WATERMAIN IN 8"0 PUBLIC o = ui EASTERN SHOULDER I WATERMAIN IN Z za�- a 00 (SEE UTILITY PLANS y I EASTERN SHOULDER o ll FOR LOCATION) (SEE UTILITY PLANS w d00 880 3 FOR LOCATION) ?CIDo 880 s 8 QO00 —�� W SOR 3 °' Coll— PI STA = 12+32.59 3' MIN. COVER o S PVC o a EL = 866.54 3 VC = 300.00 I 0� K - 15.2 I a 875 " LP STA: 12+22.69 875 18 RCP LP ELEV: 873.89 ' INV=871.88 rn � VC 1 7— ri ri ' •,n _ R 870 50 F g" SDR 35 PVC ® 2.00� 870 20 LF 8" DIP ® 8.50% " �,� 8 DIP 01.00% 8" DIP OUTSIDE — N w DROP a 865 8" DIP OUTSIDE 865 18" RCP Q DROP INV=866.37 v i `O a 72" CMP 00 INV=861.54 860 o —(STORM BYPASS 860 o W w 72" CMP (BURIED 1') a o o FLOW CULVERT) INV=860.63 o 2 (BASE FLOW CULVERT) r o a O N � ' 1 0 0 n O N It LO r- 01 O CO I� 7 M I 855 N !I, 00 (0 (0 4 ao 0 00 - 855 w^ w^ U)0000—oII II 00 n p0 Z 00 Z W Z Z W Op W 00 W . 00 v 00 . . 00 00 00 00 v 00 v 00 F— vvvv 0 Z 0 Z 0 Z Z Z Z 0 Z 0 Z > > > > > > > > > > > > > 850 zz zz zzzzz zz zz 850 9+00 10+00 1 1 +00 12+00 13+00 14+00 PROJECT REFERENCE NO. SHEET NO. 303-168 EC-1 A III SHEET NO. Z Zo2 "NA%• RO• SKIMMER BASIN WITH BAFFLES DETAIL4�4� SEAL IV. 0337 6 — l I NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C3035 DOCUMENT NOT CONSIDERED FINAL. STEEL POSTS ( QUANTITY VAR ° ) SKIMMER ( S ZE VAR . ) _______ I UNLESS ALL SIGNATURES COMPLETED Zrj,. , AF AIM SOIL S TA B I H Z AT O N Civil & Environmental Consultants, Inc. G E O T E X T I L E 3701 ARCO CORPORATE DRIVE• SUITE 400 • CHARLOTTE,NC 28273 980-237-0373.800-365-2324 —.cecinc.com P LAST C SLOPE D RA N FOR PERMITTING ONLY P PE ( 12 N ° ) 2 M I N ° NOT FOR CONSTRUCTION Date: 3/25/2021 By: ALL 1 ' MIN. 4 4' (MAX.) W 6 ' ( MIN ° 2 " x 2 " ( nominal ) 1 .5' 1 ' WOODEN STAKE MIN. MIN. 11 1 99 h N N NROPE 1 — 2 " W COIR BER MAT 1 - 2 TEMPORARY OR 99 12 24 U PERMANENT DITCH 2 (MIN .) SOIL GEO EXTIALEON -'J Mid V (MIN.) WOOD STAKE 4' ( MIN .) STONE PAD METAL POST a W I OR STAPLE o PRIMARY SPILLWAY 0 EARTH DIKE # 10 STEED 6 N . L 3W REINFORCEMENT BAR Q ( M N ° ) 3 4L COIR FIBER MAT I 3 1 Z2L SOIL STABILIZATION 499 1 4L 1 ' GEOTEXTILE IAMETER BEND MIN. 18 IN. 499 o � 1 ' (MIN. OVERLAP W MIN . ( MIN ° 9 1 ' (MIN.) 12 ��2 4 IN. (MIN.) 24" a °] 3 � MAX. w 9 MAX. UNCLASSIFIED EARTH MATERIAL C VARIABLE NATURAL GROUND I 9 CO R EBER BAFFLE 2 RIGID 1 " ( nominal ) ROADWAY STD ° DWG NO 1640 . 01 COUPLING( SEE ° ° ) UNCLASS K ED EARTH STAPLE I 0 MATER AL 1 '9 STELE POSTS PEACE SEALANT AROUND BARREL PIPE WITH MINIMUM WIDTH OF 6 IN ° CLASS B STONE PAD ( 4 ' x 49 x 1 ' MIN ° ) 12 " NOTES 1 . SHED AND PEACE MATT NG FOR EROS ON CONTROL ON LATER OR AND EZTER OR S DESLOPES ° 2 ° L UT EARTH D K C HE G HT TO 5 FT. COI R FIBER MAT 3 ° FOR BAS N DEPTH OF 3 FT. , THE M H MUM BASH W DTH SHALL BE D T° ANCHOR OPTIONS 4 ° DETERM NE PR MARY SP LLWAY WE R LENGTH ( FT. ) US NG Q 0 ° 8 , WHERE Q S COW RATE ( CC ) NTO BAS N . 5 ° PLAST C SLOPE DRA N H PE AT NLET OF BAS N MAY BE R PLACED BY K LTRAT ON GOTCT LE OR TARP AS D RECTED ° 6 ° SO L STAB L ZAT ON GEOTDT LE FOR PR MARY SP LLWAY SHALL BE ONE CONT NUOUS P ECE OF MATER AL OR OVERLAPPED 18 N . ( UN . ) . NOT TO SCALEIII PROJECT REFERENCE NO. SHEET NO. 303-168 EC-1 B WATTLE WITH POLYACRYLAMIDE PAM ) DETAIL R/W SHEET NO. %x% ;4� SEAL os3 NOTES: t �USE MINIMUM 12 IN. DIAMETER EXCELSIOR WATTLE. ��► NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND USE 2 FT. WOODEN STAKES WITH A 2 IN . BY 2 IN. NOMINAL CROSS SECTION. SURVEYORS LICENSE NO. C3035 I DOCUMENT NOT CONSIDERED FINIAL. ONLY INSTALL WATTLE(S) TO A HEIGHT IN DITCH SO FLOW WILL NOT WASH AROUND UNLESS ALL SIGNATURES COMPLETED WATTLE AND SQQ R DITCH SLOPES AND AS DIRECTED. 11AWAfA_'M INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES AT AN ANGLE Civil & Environmental TO WEDGE WATTLE TO BOTTOM OF DITCH. Consultants, Inc. 3701 ARCO CORPORATE DRIVE• SUITE 400 - CHARLOTTE,NC 28273 PROVIDE STAPLES MADE OF 0. 12 5 I N . DIAMETER STEEL WIRE FORMED INTO A 980.237-0373.800-385-2324 See Inset A www°°°'°°°°m U SHAPE NOT LESS THAN 12" IN LENGTH. FOR PERMITTING ONLY NOT FOR CONSTRUCTION EDGE OF PAVEMENT INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE Date: 3/25/2021 By: ALL AND AT EACH END TO SECURE IT TO THE SOIL. EXCELSIOR WATTLE INSTALL MATTING IN ACCORDANCE WITH SECTION 1 631 OF THE STANDARD SPECIFICATIONS. er Q� PRIOR TO POLYACRYLAMIDE (PAM) APPLICATION, OBTAIN A SOIL SAMPLE FROM PROJECT LOCATION , AND FROM OFFSITE MATERIAL, AND ANALYZE FOR APPROPRIATE PAM FLOCCULANT TO BE APPLIED TO EACH WATTLE. MATTI N G BACK INITIALLY APPLY 2 OUNCES OF ANIONIC OR NEUTRALLY CHARGED PAM OVER WATTLE WHERE iiz SLOPE WATER WILL FLOW AND 1 OUNCE OF PAM ON MATTING ON EACH SIDE OF WATTLE. REAPPLY PAM AFTER EVERY RAINFALL EVENT THAT IS EQUAL TO OR EXCEEDS 0.50 IN. 121 N Z PAM N O W • (2 0Z.) 0 ISOMETRIC VIEW c ,U i FLOW O • • •• ••• J 2 ' ( MAX . ) 2 ' UPSLOPE STAKE NATURAL GROUND STAKES STAPLES PA PAM INSET A ( 1 oz.) INSET B ( 1 oz.) INSET C I 3 a c a 0 c 0 U 0 12"(MI ) MATTING 2 ' DOWNS �OPE UPSLOPE 31 STAKE DOWNSL0P CROSS SECT ON STAKE STAKE a VEE DITCH PAM (1 0Z.) a I 2 1 N . See Inset C 2 ' U P S LO P E VAR. STAKE NATURAL GROUND FLOW I / 0 a Pq 0 See Inset B MATTING (1 0Z.) 2'(MIN. 6'(MIN. MATTING 2 ' DOWNSLOPE do ow CROSS SECTON STAKE - TRAPEZOIDAL DITCH TOP V EW PROJECT REFERENCE NO. SHEET NO. 303-168 EC-1 C VA \ G \ S A — A 0 \ :D A R/W SHEET NO. 2 yo2 ols �w SEAL 0337 6 1 H E \ C C ''' III I I _ I I ' ( M \ o ) G D 0 UJ D NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND 11 _ Ell I MI I I— I I— 1 SURVEYORS LICENSE NO. C3035 1- 1 DOCUMENT NOT CONSIDERED FINI.m- B A C \ \ UNLESS ALL SIGNATURES COMPLETED A 'a— AF 11AWAfA 'M 6 99 Civil & Environmental ( M N . ) Consultants, Inc. STAR LES 0 R 1 -1 - � 0 9 � �� 11 3701 ARCO CORPORATE DRIVE• SUITE 400 CHARLOTTE,NC 28273 _ ( 980.237-0373.800-366-2324 1 www.cecinacom 1 =1 - — 99 B ) 11= \\C �\\ : . . " - " \\ �\\�\� 1 9 CENTERS --  1 0 r - I I '� ' FOR PERMITTING ONLY -1 = TRENCH 4 99 �I NOT OR CONSTRUCTION 1 ) 1- 1 0 Dat y C 1 0 „ I- 1= 11 MI I I- 1. ' 1 0 " 1 MI I I- 99 C 9 9 Ell I 1= 0 WN = 11— 6 = I— N STAPLE - = I CHECK _-_-1 I_- cn MATT C SHALL B E �TAO HC 0� Z N PLACED D TRENCH V CENTERS W MATTING IN DITCHES AND BACER FEED H TRENCH 0 ,U DAGRAM CA J Q U O q A Stap � e Check Pattern 10 A a o 99 1 99 0 0 0 99 0 Staple U '7 9 9 1 9 a Staple \ Check Staple 99 a C DAGRAM c MATTING ON SLOPES DAGRAM B NOTES: THIS DETAIL APPLIES TO STRAW, EXCELSIOR , AND PERMANENT SOIL REINFORCEMENT MAT ( PSRM ) INSTALLATION . STAPLES SHALL BE NO . 11 GAUGE STEEL WIRE FORMED INTO A "U " SHAPE WITH A MINIMUM THROAT WIDTH OF 1 INCH AND NOT LESS THAN 6 INCHES IN LENGTH . NOT TO SCAB PROJECT REFERENCE NO. SHEET NO. 303-168 EC-1 D R/W SHEET NO. Os 2 Zo2 `���Ul Illl//V �$. •ki Ix � BAIp•mod-y�� kw SEAL ter• 0337 6 ; NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C3035 I DOCUMENT NOT CONSIDERED FIN&L. UNLESS ALL SIGNATURES COMPLETED AV 111AW r z Cf) z o 0C/) Civil & Environmental Q Q Q Q Consultants, Inc. 8 MAX. WITH WIRE Q � Q �� (6' MAX. WITHOUT WIRE) H () H =C) 3701 ARCO CORPORATE DRIVE• SUITE 400 CHARLOTTE,NC 28273 LL J o F-I LL J 0 F-I 980.237-0373.800-365-2324 0 0 = z NOTES 0 0 =z www.cecinc.com LLJ0 =o� 1 . PROVIDE TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE �0=o� FOR PERMITTING ONLY MIDDLE AND VERTICAL WIRES Q = z ~ TRUCKS. Q ~' SHALL BE 12%2 GAUGE MIN . � � 0"' �� zo w NOT FOR CONSTRUCTION LL 2. LOCATE ENTRANCES TO PROVIDE FOR UTILIZATION LL or 0 I-I Q M 0 F-I Q Date: 3/25/2021 By: ALL 0 cn BY ALL CONSTRUCTION VEHICLES. 0 cn z ~ 3. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT z •'-' 00 I o TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. o TOP AND BOTTOM STRAND r LU PERIODIC TOPDRESSING WITH STONE WILL BE NECESSARY. w SHALL BE 10 GAUGE MIN . Hill 24" MAX. '' / 4. ANY MATERIAL TRACKED ONTO THE ROADWAY MUST BE r ( 18" MIN . ) // CLEANED UP IMMEDIATELY. / 5. LOCATE GRAVEL CONSTRUCTION ENTRANCE AT ALL POINTS OF / INGRESS AND EGRESS UNTIL SITE IS STABILIZED. PROVIDE EBII 1-T�Tf-ITI-1T1-1 I I-1TI -i�T I I-1TI-1(I-1 I-1TI-1 I-1TI-1 -1TI-1 I -1 I-1 I-1 T I-T�TI-T-ITI-11 E 1TI� 17116 1 EI E I I-T-1TI-1TI-1 I-1TI-1 -1TI / FREQUENT CHECKS OF T H E DEVICE A N D TIMELY MAINTENANCE . / Q4 6. NUMBER AND LOCATION OF CONSTRUCTION ENTRANCES TO W / Q�� BE DETERMINED BY THE ENGINEER. v 121: // ��G 7. USE CLASS 'A' STONE OR OTHER COARSE AGGREGATE APPROVED Z Cr < WIRE o W S BY THE ENGINEER. o V / QJ �,�, 8. INSTALL CONSTRUCTION ENTRANCES IN A WAY TO PREVENT VEHICLES LL CD Z / FROM BYPASSING CONSTRUCTION ENTRANCE LEAVING PROJECT SITE. CD Z GEOTEXTILE z W // z W o NOTES cn o ~ 00 p USE GEOTEXTILE A MINIMUM OF GEOTEXTILE ~ ~ cn 36" IN WIDTH AND FASTEN ADEQUATELY Q Q > TO THE POSTS AND WIRE AS DIRECTED. COMPACTED FILL > o pC USE WIRE A MINIMUM OF 32" Q 0 IN WIDTH AND WITH A MINIMUM Ct) U) Z } O CLASS 'A' STONE V OF 5 LINE WIRES WITH 12" VERTICAL TTE W 8 IN. MIN . DEPTH o J SPACING. 7I I I I I r37o � � I II I I I—I I I I I I ¢ Q PROVIDE 5'-0" STEEL POST OF o ff o W o THE SELF-FASTENER ANGLE STEEL o °C °C > N TYPE . 4„ STEEL POST - 2'-0" DEPTH NOTE: PLACE GEOTEXTILE FOR DRAINAGE BENEATH STONE FOR MECHANICAL SLICING METHOD O INSTALLATION, GEOTEXTILE SHALL QBE A MAXIMUM OF 18" ABOVE GROUND SURFACE . EXTENSION OF GEOTEXTILE AND WIRE INTO TRENCH SHEET 1 OF 1 SHEET 1 OF 1 1605 . 01 11607 . 01- C U) O H } o H0~C�0 y LLJOH W 0 0 cc: C = z W � C o NOTES C.D cr = I-- zw v �I.-_ U_0 J EXCAVATE TEMPORARY DIVERSION WITH NON -VERTICAL SIDE SLOPES AND NOT o o"< GREATER THAN 1 . 5 : 1 SLOPE . w z H wIL T y Uj 3 STABILIZE TEMPORARY DIVERSION AS DIRECTED . 0 °o v i i o COMPACTED SOIL Cc o —► 2' MINIMUM LL Z O CD N FLOW -611 = MINIMUM CC > H o p cc o > 6' TYPICAL < Q U O Qa 3= Q H CROSS SECTIONAL VIEW Cc SHEET 1 OF 1 1630 . 05 PROJECT REFERENCE NO. SHEET NO. 303-168 EC-2 R/W SHEET NO. C TY OF H CKORY ����'�.•ROE �/� 4� • 4F�8EAtD�y9' 0337 6 — /ll I NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SO L STAB L ZAT ON SUMMARY SHEET SURVEYORS LICENSE NO. C3035 DOCUMENT NOT CONSIDERED FINAL I UNLESS ALL SIGNATURES COMPLETED MATT NG FOR EROS0N CONTROL //7'WIRAIM;AW Civil & Environmental C O N S T FROM TO Consultants, Inc. SHEET N0 . LINE STAT O N STATION SIDE E S T I MATE (SY) 3701 ARCO CORPORATE DRIVE• SUITE 65-• CHARLOTTE,NC 28273 980-237-0373.800-365-2324 www.ceanc.com EC-4 —L— 10+50 13+00 LT 335 FOR PERMINOT FOR oTTIRNG ONLY ON Date: 3/25/2021 By: ALL EC-4 —L— 10+00 13+50 RT 470 a h 0 N a Z O I N t � w Ix U I O N �i i e 0 ti m Q N W a a y 0 R w Al 0 h O W W I U 6 O w q) 3 O O V I I O O O O a PROJECT REFERENCE NO. SHEET NO. 303-168 EC-2A R/W SHEET NO. OsC TY OF H CKORY 2 Zo2 `� Ul Illl// SEAL ,�t► �1i CAR p����� 0337 6 ; NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND SURVEYORS LICENSE NO. C3035 DOCUMENT NOT CONSIDERED FINIAL. SO S A3 A 0 \ V AV SI UNLESS ALL SIGNATURES COMPLETED AV 111AW � r Civil & Environmental Consultants, Inc. 3701 ARCO CORPORATE DRIVE• SUITE 400 - CHARLOTTE,NC 28273 980.237-0373.800-365-2324 www.cecin—cm FOR PERMITTING ONLY NOT FOR CONSTRUCTION Date: 3/25/2021 By: ALL a h i N N Z ° SITE DESCRIPTION STABILIZATION TIME T MEERAME EXCEPTIONS w t cc ,U VI I O N PERIMETER DIKES , SWALES , DITCHES AND SLOPES 7 DAYS NONE J HIGH QUALITY WATER ( HQW) ZONES 7 DAYS NONE h ti m e F SLOPES ARE 10 ' OR LESS IN LENGTH AND ARE N SLOPES STEEPER THAN 3 : 1 7 DAYS a NOT STEEPER THAN 2 : 1 , 14 DAYS ARE ALLOWED . 0 a 7 DAYS FOR SLOPES GREATER THAN 50 ' IN 0 SLOPES 3 : 1 OR FLATTER 14 DAYS LENGTH . I I 0 a ALL OTHER AREAS WITH SLOPES FLATTER THAN 4: 1 14 DAYS NONE , EXCEPT FOR PERIMETERS AND HQW ZONES . 3 O O U I b I O O O I O EROSION AND SEDIMENT CONTROL MEASURES PROJECT REFERENCE NO. SHEET NO. Sid. Descri tp ion Symbol 303-168 EC-3 1630.03 Temporary Silt Ditch TSD Ill SHEET NO. 1630.05 Temporary Diversion TD III , Z ZOZ 1605.01 Tem orar Silt Fence 0�'�Alr 1����/� ' p Y '41�.. RCE���� 1606.01 Special Sediment Control Fence 1622.01 Temporary Berms and Slope Drains `— `— SEALr'= 0337 6 _ 1630.02 Silt Basin Type B • zz Dv O / / I 1 1633.01 Temporary Rock Silt Check Type—A �� •. ti\�� 00 Temporary Rock Silt Check TypeA with z / / / I Matting and Polyacrylamide (PAM) NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND w o / SURVEYORS LICENSE N0. C3035 1633.02 Temporary Rock Silt Check Type—B ' DOCUMENT NOT CONSIDERED FIN�.i Wattle/Coir Fiber Wattle CFw / Ew I UNLESS ALL SIGNATURES COMPLETED / ,A / Wattle/Coir Fiber Wattle AV with Polyacrylamide (PAM) ' ��� / 111AW 7 1634.01 Temporary Rock Sediment Dam T e—A � p Y Yp � o � Civil & Environmental 1634.02 Temporary Rock Sediment Dam Type—B Consultants, Inc. —� Rock Pipe Inlet Sediment Trap T eA 3701 ARCO CORPORATE DRIVE• SUITE 400 CHARLOTTE,NC 28273 i 1635.01 p p Y p 980.237-0373•800-366-2324 www.cecinacom 1635.02 Rock Pipe Inlet Sediment Trap TypeB —U o /,890� ,/' /,/' ��� ���' . 1630.04 Stilling Basin FOR PERMITTING ONLY NOT FOR CONSTRUCTION 1630.06 Special Stilling Basin Date: 3/25/2021 By: ALL Rock Inlet Sediment Trap: SCALE IN FEET 1632.01 Type A A 0 20 40 1632.02 Type B B / / 3 CLEARING AND GRUBBING EROSION CONTROL FOR ,A / CONSTRUCTION SHEET 4 LIMITS OF 10 1632.03 Type C C DISTURBED AREA DISTURBANCE PROPOSED TREE LINE / 87,120 SF OR 2.0 ACRES a2 Skimmer Basin PROPOSED O TEMPORARY SILT Tiered Skimmer Basin N FENCE (TYP.) Infiltration Basin cn i �-A / / /� LIMITS OF DISTURBANCE PROPOSED TREE LINE LU STREAM TOP OF BANK / / I STREAM BOTTOM OF BANK I I \ \ \ PROPOSED TEMPORARY o DIVERSION �O j/ // I I I� I I I UZI oo \ �A _ �\ I i I— CONTRACTOR TO PUMP STREAM \ AROUND WORK AREA DURING I PROPOSED TREE LINE \ CLEARING AND GRUBBING OPERATIONS I \ / J o WATTLE WITH PAM �O � / / / / //T_ �� (CONTRACTOR SHALL REMOVE PUMP LIMITS OF i (TYP.) / / / / /', / / ONCE CULVERTS ARE INSTALLED) I DISTURBANCE \ \ TROPOSED EMPORARY SILT /��'��� FENCE (TYP.) � Oly I I R o / O PROPOSED TEMPORARY W Ri W DIVERSION Ry W W W 0 , PROPOSED TEMPORARY I I \ DIVERSION I I \ \ / Tp / 0/ / / \ / I it / Oy W / R R R W W W W a W 41 01 // \� I iI W W W W a— O 1 a— 1 o-- �l �— a 1 41 �— 1 i l 41 a� 41 TEMPORARY � i 01a� 4 SKIMMER BASIN #1 41C�� dl a� 0l E� Q 1 �� a l a� I PROPOSED TEMPORARY DIVERSION PROPOSED TREE LINE I o I / STREAM TEMPORARYxl� I I BOTTOM OF SKIMMER BASIN #2 BANK I / UNNAMED TRIBUTARY TO MUDDY CREEK STREAM TOP OF BANK I I I I I I I II \ �� I I C9 I \ EROSION AND SEDIMENT CONTROL MEASURES PROJECT REFERENCE NO. SHEET NO. Sid. Descri tp ion Symbol 303-168 EC-4 1630.03 Temporary Silt Ditch TSD Ill SHEET NO. 1630.05 Temporary Diversion — TD , Z&1; ZOZ 1605.01 Tem orar Silt Fence 0�'�Alr ���/� ' p Y '41�.. RCE���� 1606.01 Special Sediment Control Fence 1622.01 Temporary Berms and Slope Drains ~ ~ = :Q� SEALr'= 0337 6zz _ 1630.02 Silt Basin Type B • w (0 // / // 1633.01 Temporary Rock Silt Check Type—A �� •. +�\�� w k / �/ / / I ��► i � O / ' / / / / I Temporary Rock Silt Check T eA with z / / / I Matting and Polyacrylamide (PAM) NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND n A / / SURVEYORS LICENSE NO. C3035 00 1633.02 Temporary Rock Silt Check Type—B ' DOCUMENT NOT CONSIDERED FI (A / EW—CFw N�.i Wattle/Coir Fiber Wattle UNLESS ALL SIGNATURES COMPLETED ,A / Wattle/Coir Fiber Wattle A AV with Polyacrylamide (PAM) ' ��� / 111AW 7 1634.01 Temporary Rock\\ Sediment Dam Type—A Civil & Environmental„ 1634.02 Temporary Rock Sediment Dam Type—B Consultants, Inc. \ / / es & 3701 ARCO CORPORATE DRIVE• SUITE 400 - CHARLOTTE,NC 28273 1635.01 Rock Pipe Inlet Sediment Trap Type—A 980.237-0373.800-365-2324 www.cecinacom 1635.02 Rock Pipe Inlet Sediment Trap TypeB \ ,S9o� ,�' ,�' 1630.04 Stilling Basin FOR PERMITTING ONLY NOT FOR CONSTRUCTION 1630.06 Special Stilling Basin Date: 3/25/2021 By: ALL Rock Inlet Sediment Trap: SCALE IN FEET 1632.01 Type A A 0 20 40 1632.02 Type B B 13 DISTURBED AREA _ / 87,120 SF OR 2.0 ACRES O �0 LIMITS OF o0 1632.03 Type C C DISTURBANCE \ PROPOSED TREE LINE / aC2 Skimmer Basin PROPOSED o TEMPORARY SILT Tiered Skimmer Basin FENCE (TYP.) , Infiltration Basin J Z i // /�� � LIMITS OF DISTURBANCE t INLET PROTECTION — / i i N TYPE C (TYP.) �� �� PROPOSED TREE LINE > / // I STREAM TOP OF BANK I I STREAM BOTTOM OF BANK PROPOSED TEMPORARY I I \ \ \ N DIVERSION �� I I li I CLASS B RIP—RAPUZI I $ \ CONTRACTOR TO PUMP STREAM \ AROUND WORK AREA DURING I PROPOSED TREE LINE \ \ CLEARING AND GRUBBING OPERATIONS I WATTLE WITH PAM �� >>X y _ (CONTRACTOR SHALL REMOVE PUMP LIMITS OF (TYP.) / 0O 9 ONCE CULVERTS ARE INSTALLED) I DISTURBANCE INLET PROTECTION — << PROPOSED TYPE C 9TYP.) \ I TEMPORARY SILT N o �� aC) w I I I FENCE (TYP.) \ U / TQ R W W �o I �2+00 / 14+00 I \ 15+00 TD / fV`�' 01 o-- El 01 TEMPORARY a O1 �� 0 01 a / SKIMMER BASIN #1 ,y�T Ol�a� O1 E— 01 PROPOSED TEMPORARY DIVERSION PROPOSED TREE LINE I o I I I I STREAM TEMPORARY 1 I I BOTTOM OF SKIMMER BASIN #2 I // I(� BANK \ I I UNNAMED TRIBUTARY TO MUDDY CREEK STREAM TOP OF BANK I I I I I I I II \ �9 I I I \ PROJECT REFERENCE NO. SHEET NO. \ ` SCALE IN FEET 303-168 UC-1 A 0 20 40 R/W SHEET NO. Z 0 Z�. Zo2 0 -8816 SEAL A 6 z oG �9'• �Q � �i ♦♦ v c� Z 00 Ill I NORTH CAROLINA BOARD OF EXAMINERS FOR ENGINEERS AND 0 SURVEYORS LICENSE NO. C3035 00 9 I DOCUMENT NOT CONSIDERED FINIAL. UNLESS ALL SIGNATURES COMPLETED AR EXISTING Z ,� � � SS MANHOLE 1000 RIM = 873.10 INV IN = 866.34 CivilEnvironmental INV OUT = 866.24 Consultants, Inc. 3701 ARCO CORPORATE DRIVE• SUITE 400 - CHARLOTTE,NC 28273 %p 980.237-0373.800-365-2324 4' DIA. MANHOLE \ w—cecln—cm RIM=889.92 SS107 INV. IN (8"NW)=882.90 A �0 FOR PERMITTING ONLY INV. OUT (8"SE)=882.70 x NOT FOR CONSTRUCTION �3 00 Date: 3/25/2021 By: ALL S �v SS -o i STREAM TOP OF IIjjI BANK I STREAM BOTTOM OF I I I BANK I I I I h cn s r � a / ► � , I_� ) N0 4' DIA. MANHOLE N RIM=883.30 SS106 SS >>X W INV. IN (8 NW)=875.62 00 T INV. OUT (8"SE)=875.42 ,rt� �q�� J 11" U lJ PROPOSED PROPOSED PROPOSED 8"0 o l W I I UNDERGROUND UNDERGROUND i ELECTRICAL TELEPHONE LINE PUBLIC WATER MAIN t T ( LINE (MIN. 3' COVER) \ SS W R I I R R R R R R R R P \ T 11 SS T T 4' DIA. \ \ 8" D/p W y W T T T T W W W W W yy yy W DOGHOUSE MANHOLE ' RIM=876.79 SS 100 \ \ / "12+0p / W W W W INV. IN (8'E)=868.75 T INV. IN (8"NW)=868.75 INV. IN (8"NW)=864.17(OUTSIDE DROP) _SS ► 13+00 8" SDR 35 PVC INV. IN (8"E)=864.17 (OUTSIDE DROP) T / 8" SD 8 5 PVC _ SS _ c c _ INV. OUT (12"SW)=864.17 I 14+00 15+00 T T T T T T T T T T �y T W W W W {�' W 4' DIA. MANHOLE / PROPOSED SS 103 o / / RIM=895.93 UPROPOSED 8"0 PROPOSED UNDERGROUND DR 35 PVC UNDERGROUND TELEPHONE LINE INV. IN (8"E)=889.62 SANITARY SEWER ELECTRICAL INV. OUT (8"W)=886.23 PIPE LINE SS 02 4' DIA. MANHOLE i 4' DIA. MANHOLE RIM=875.84 R UNNAMED i c� / RIM=874.14 SS101 INV. IN (8"E)=871.35 U i TRIBUTARY TO INV. IN (8"E)=870.15 INV. OUT (8"W)=871.15 �° a� MUDDY CREEK ( i / INV. OUT (8"W)=869.95 0 � I STREAM I 0 1 TOP OF BANK o �✓/ / STREAM BOTTOM OF BANK co a� EXISTING / SS MANHOLE 1002 / RIM = 865.28 INV IN = 859.86 INV OUT = 859.76 / c