Loading...
HomeMy WebLinkAboutNC0086291_Inspection_20211103United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 IN I 2 I5 I 3 I NC0086291 111 121 21/11/02 117 Type 18 H 11111111111 Inspector Fac Type 191 S I 201 . I 21111111 11111111111 1111111 I I IIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 I 70I3 I 711 1 72 I N I 731 1 74 71 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Beaver Hill WTP Albemarle Rd Edenton NC 27932 Entry Time/Date 10:OOAM 21/11/02 Permit Effective Date 18/08/01 Exit Time/Date 11:OOAM 21/11/02 Permit Expiration Date 23/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Not Required/ORC/919-807-6353/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Anne -Marie Knighton,PO Box 300 Edenton NC 279320300/Town Manager/252-482-7352/2524827377 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Robert E Bullock DWR/WARO WQ/252-948-3843/ 11 /3/2021 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 3I NPDES yr/mo/day NC0086291 111 121 21 /11 /02 117 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The review period for this inspection was April 2017 through October 2021. Four Notice of Deficiencies were issued over the review period. The NPDES permit has a Chloride limit of 230 mg/I that will become effective on August 1, 2022. A review of the DMR's showed that the facility currently cannot meet the Chloride limit of 230 mg/I. The effluent discharge will need to be meet permitted limits of 230 mg/I by August 1, 2022. The facility is currently reporting flow from one backwash on the DMR. Total daily discharge needs to be reported on the DMR. During the recent upgrade Mag Meters were installed to measure effluent flow. Effluent flow meters are required to be calibrated annually with a maximum deviation of 10%. Grab samples are taken as required in the NPDES permit. The facility currently only samples the exchange softeners. Effluent samples need to be representative of the actual discharge and include the pressure vessels (PurolitePlus/9218) and the exchange softeners. Page# 2 Permit: NC0086291 Inspection Date: 11/02/2021 Owner - Facility: Beaver Hill WTP Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El ❑ ❑ application? Is the facility as described in the permit? • El El El # Are there any special conditions for the permit? • El El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: The current permit expires on July 31, 2023. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? • ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? • ❑ ❑ ❑ # Is the facility using a contract lab? • El ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • ❑ ❑ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? El ❑ • ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? El El • El Comment: Field parameters are analyzed by JLA with all other samples sent to Environment 1 for analysis. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • ❑ ❑ ❑ Is all required information readily available, complete and current? • ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Page# 3 Permit: NC0086291 Inspection Date: 11/02/2021 Owner - Facility: Beaver Hill WTP Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Dates of analysis ❑ Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ▪ ❑ ❑ ❑ ❑ ❑ • ❑ Comment: The September 2021 DMR was spot checked for accuracy. The facility is currently reporting flow from one backwash on the DMR. Total daily discharge needs to be reported on the DMR. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ ❑ • ❑ ❑ ▪ ❑ ❑ ❑ ❑ ❑ • ❑ Comment: During the recent upgrade Mag Meters were installed to measure effluent flow. Effluent flow meters are required to be calibrated annually with a maximum deviation of 10%. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ • ❑ ❑ Is sample collected below all treatment units? ❑ • ❑ ❑ Is proper volume collected? • ❑ ❑ ❑ Is the tubing clean? ❑ ❑ • ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑ representative)? Page# 4 Permit: NC0086291 Inspection Date: 11/02/2021 Owner - Facility: Beaver Hill WTP Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE Comment: Grab samples are taken as required in the NPDES permit. The facility currently only samples the exchange softeners. Effluent samples need to be representative of the actual discharge and include the pressure vessels (PurolitePlus/9218) and the exchange softeners. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: No adverse conditions were noticed on the day of inspection. Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, MODE and sampling location)? Comment: Page# 5