Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0023868_Industrial User_20211026
Cit of Xristy Xing t;� ► c IndustriaCPretreatment SpeciaCist -a4.0 October 18, 2021 Mr. Adrian Ridley Labcorp 1447 York Court Burlington,NC 27215 Subject: Industrial User Permit# 0066 Permit Renewal Dear Mr. Ridley, Enclosed please find the user permit issued to Labcorp. This permit regulates the wastewater that is discharged to the South Burlington Wastewater Treatment Plant. This permit becomes effective January 01, 2022 and expires December 31,2026. Please read this permit carefully and retain it in your filing system. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the City of Burlington Sewer Use Ordinance. If any measurement frequencies or sampling requirements contained in this permit are unacceptable,you have the right to an adjudicatory hearing upon written request within thirty (30) days following the receipt of this letter. The Cityof Burlington reserves the right to modifythispermit as necessary. These limitations � and requirements may change at any time during the permit period as deemed necessary by the City of Burlington. If you have any questions,please feel free to call me at(336)222-5133. Sincerely, /44-r7)-- ‘ Kristy King Industrial Pretreatment Specialist City of Burlington Connecting the Triad and the Triangle 1302 Belmont Street PO Box 1358—Burlington,NC 27216 Phone 336-222-5133—www.BurlingtonNC.gov City of Burlington Control Authority and/or Municipality PERMIT Industrial User Pretreatment Permit(IUP) To Discharge Wastewater Under the Industrial Pretreatment Program 0066 N/A IUP Number 40 CFR Category(if Applicable) In compliance with the provisions of North Carolina General Statute 143-215.1, any applicable federal categorical pretreatment regulations, all other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Control Authority and/or Municipality Sewer Use Ordinance. The following Industry, hereafter referred to by name or as the permittee: Industry name,permittee: Laboratory Corporation of America Facility Located at Street Address 1447 York Court City Burlington State,Zip North Carolina 27215 is hereby authorized to discharge wastewater from the facility located at the above listed address into the sanitary sewer collection system and the wastewater treatment facility of the Control Authority and/or Municipality listed below: IUP Control Authority and/or Municipality WWtP name: South Burlington Wastewater Treatment Plant NPDES Number. NC0023876 VWVTP Address: Boy Wood Road City,State,Zip Burlington,North Carolina 27215 in accordance with effluent limitations, monitoring requirements, and all other conditions set forth in Parts I, II, and III of this Industrial User Pretreatment Permit(IUP). Effective date, this permit and the authorization to discharge shall become effective at midnight on this date:. January 1, 2022 Expiration date,this permit and the authorization to discharge shall expire at midnight on this date: December 31, 2026 C P.,L1 v�13D12.¢1z1 Water Resources Director Water Resources De Title Industrial User Pretreatment Permit (IUP) PART I • Specific Conditions Continued: IUP History IUP, PART I, OUTLINE: A.) IUP Basic Information B.) IUP Modification History C.) Authorization Statement D.) Description of Discharges E.) Schematic and Monitoring Locations F.) Effluent Limits&Monitoring Requirements G.) Definitions and Limit Page(s)notes A. IUP Basic Information: Receiving Control Authority&WWTP name: POTW NPDES#: South Burlington Wastewater Treatment Plant NC0023876 IUP Name: IUP Number: Laboratory Corporation of America 0066 IUP Effective date: Pipe Numbers,list all regulated pipes: January 1, 2022 01 IUP Expiration date: IUP 40 CPR#(if applicable),or N/A: December 31, 2026 N/A B. IUP History. Effective New/Renewal or Description of changes over previous IUP. Date Modification 1/31/1996 Modification Roche Medical Reference Laboratories merged with another clinical laboratory company and the new name is Laboratory Corporation of America Holding. 1/1/1997 Renewal New Permit issued, former permit expired December 31, 1996. 9/30/1997 Modification pH limit changed to 5 to 10 units. 1/1/2002 Renewal New Permit issued,former permit expired December 31,2001 and Industry will sample semi- annually and POTW will sample semi-annually. Temperature Limit increased to 50 degree Celsius from 40 degree Celsius. 2 z Industrial User Pretreatment Permit (IUP) PART I Specific Conditions Continued: IUP History 11/01/2002 Modification pH limit changed to 5 to 11 units. 7/01/2003 Modification Monitoring for Aqueous CTAS and Surfactants as MBAS no longer a permit requirement. 10/6/2005 Modification Zinc limit increased to 1.00 lbs/day from 0.20 lbs/day. 1/1/2007 Renewal New Permit issued, former permit expired December 31,2006. Zinc limit reduced to 0.50 lbs/day from 1.00 lbs/dat. Mercury limit is 0.0015 lbs/day changed from monitor only. 1/1/2012 Renewal New Industrial User Permit issued, former permit expired December 31, 2011. 1/1/2017 Renewal New Industrial User Permit issued,former permit Modification expired December 31,2016. Quarterly sampling schedule will change to POTW sampling 1st and 3rd quarters of the calendar year, and industry will sample 2nd and 4th quarters of the calendar year. Pipe#02 was added due to new construction. Pipe #01 is located at the original site. Pipe#02 sampling point is located at the end of the main driveway before it joins sewer line at Front St. Effluent limits were divided evenly between the two pipes except for the Mercury(Hg) limit. Hg for Pipe#01 is 0.001125 lbs/day, and Hg for Pipe #002 is 0.000375 lbs/day. 1/1/2022 Renewal New Industrial User Permit issued,former permit expired December 31,2021. 3 Industrial User Pretreatment Permit (IUP) PART I Specific Conditions Continued: IUP History C.) Authorization Statement: 1.) The Permittee is hereby authorized to discharge wastewater in accordance with the effluent limitations, monitoring requirements, and all other conditions set forth in this Industrial User Pretreatment Permit(IUP)into the sewer collection system and wastewater treatment facility of the Control Authority and/or Municipality. 2.) The Permittee is hereby authorized to continue operation of and discharge wastewater from the following treatment or pretreatment facilities. These facilities must correspond to the treatment units listed on both the application and inspection forms. IU Treatment Units List all Treatment Units: Descriptions: NONE 3.) The Permittee is hereby authorized to, if required by the Control Authority and/or Municipality and after receiving Authorization to Construct (A to C) from the Control Authority and/or Municipality, construct and operate additional pretreatment units as needed to meet final effluent limitations. D.) Description of IUP Discharge(s): 1. Describe the discharge(s) from all regulated pipes. Pipe# 01 and 02� Description of Discharge: Wastewater from both pipes is generated from clinical laboratory diagnostic testing and domestic usage. E.) Schematic and Monitoring Locations: The facility schematic and description of monitoring location(s) given below must show enough detail such that someone unfamiliar with the facility could readily find and identify the monitoring location(s) and connection to the sewer. Include and identify all regulated pipes. 4 1 Labcorp — York Court Sample Points o,i'r i ,! .r"' %: .r�� alb" . y: ri-{ - y. ,t , i • . s' SAMPLE. ''.k .mottJ~S.f" , - f POINT#1 :: F; . /NT .._ ., ;: r O s .!,. _ .. ��,,,, , lit , r.'t d@`„a is .t 7, j064. I ,4,,..,.. r - •G "' r� fie' . cO .. .tionA �- +'�r 14."fir;+' . • % irt i 1, 4, iYO. / 2:,•„ . , .0 li,44-.-1,L, r . • "7 r_ r t ' J / ,, *r� +c1 t ,.r � 'Itri. It ' ,or 1%. tf: )'41 t S t `f • t 1 t - _ y 3 # f A X.K .;it rs ) r h ti'♦d f _ j , •,..., t "rr. r ,,, SAMP` Ir ,° 'i ,i`. . 'k •, w :r • •a 1 I ►}t , ' " POINT#2 Pi'. k� r • ' ti � • / P i a R•.. .. . ,.(. • l. f 7. y ,,V 1,11, A i.) { .i- :_v '. '` ",.4 . 7 tic' vh e'.l p4 0, C.-.---.)1 it 4,Q0.',11 •4 0#3 1. : .% i) WjFront -; ,,... �► . `' ' , '' .. erAl • .,.�: _ de •10,1 • front St ___ _ jt.. .. . t. �" '`1i tea+. "."4 ,# .4 IV —i v.:a ... • • • O.*. .'•g, '# i J$ ¢ y .1 .fgty —.: 03 �:, *s t •-��: 'O. h. ''flt c a - r Y ., ••• - }y 41�`.}t� •yu. r, t .F `°T r k •1 S. .,�. CJ;:r• <! K. �,•y .14• v ,!'. x ✓`•r •t,t . i ,�, r 1 t,, t L.- 4 .1:- C yy` ` �t J :•••• - ♦ f1,. ty `V4S'�1 i 4A #rh'l,j= • 4 • t� If t •2 4�xx sri w}K+ ti.:. i a, t fAa l s"sxf 'r r1{' t� �"�''. `,fy, �14�.7 r i�F:4.• i �� ti ,,y�. �. '� a i.�y i . � � ��d. � G 7 .r 9 ... '. ,��•a"'y*' .na. l ) '. a t- -. \ :i', . ,,•. _ ,'�t`i}� a{.•. si. � • ftrr p7 1 Sy r ,, a A k ti #R �y,r ' ,r .. �.« V4 .f -+� 4 , 555 i M - S 1 } a as, t 'N "5., 3� .yx is 7 �• l I '� � . � t� s iL �1Ck } yY •d � f • '' r.+ ) . R / •( �. §E ', Kati• r .u. my •+ k • + t ' '4' . sr H' i `' r'�''1i r,- i��f"ylr.�-,: t } ;c.` y rUli, y' ..� � v t'('•, -^51 f ; • r ...' ' I ` • 5. -fi+'t i sav 4i';: `r F t i 'r 9'f r i•j • s �..' ',. •. j(yjJ • a Ji f t • • b s _3e3 tl ` 3 t' v�' • Ile yfti fi „� • f ® }f,'. n - 1n5 {' j �' +.f?� �h 4�K'} ,-vim`, ,.�.- _ •�S {. . #_ ' `N',4If _ x , i .` 1 ry 1 y�,.y :.2Y f.', .," 6 'his )• fii,W t } h� !�' ,•{.:. +i a•}r4 L U. _ J a s u '}t 'a - J: f• i. :, _ � a '` •;^r31 c v y r3- sY a -' rl r.7,t+T ti to r ,.1.1 „ • � , ,' • ,# .. f• �. n z-,. o ,. yJ • ( -•J ..' ' t sir x • tY•n' r w 1( 2,.+ r 1 111 P ,6 rr":`x (:Is�7v .r`T • 3� 'F;d6r di, ry _ �'"°'� • uq�r' t!b,i ,� • j, r4y. ,t ' ' '''; ' ' '-'''''-'''';'`—_ �`q � � .�ir"cr !i t , f yh ..� ,.... {S....�Lf� - y(Y ‘„,...,, tje .yy !T ry 5 1 1L cr+rz Yr�f'"s y ,•,�_f} -. •�'bfi}a rY {,. - - tz� 1 ,a rr� w � , - - ,,, . •.-i -.. • n . ittif tea + a e , 71, "( rvT� �+. }• r ' is'' r ,t f"• i err• iV .� F>' #-•i --.T. n sv s }1 41;:,: 11. s a ,y Jai , . - `'}t � ,LA6 ) }: a• t+ h yr Ql v c "i 1 `` • 1 Fio ea t ,,� � " f =4 '° + f / r _ • As, . • ilk f y• •# ma's b 1 .V{ ;#A } . '. G5r _ },., r.�.. yaw• '`' ' ,f �` •, + ;. "4 �,x '"s '• # �•!x*'e ._ ._ _' ' � ein Ai • L��"^ u .• 'l air,' z <r. - N7---. • , T<la �,.u'.. _ � ?f. + ddJ ~ .�. 1mth=900 feet York Court - LABCORP ` '0N JN1MYHd W.91 WNI WKI. WMt W/9 • " W1y Wa1 op/ ffe oaTsl —dim ="7"..71 :17.12MMIldria: 7:=Ilmems...1.4r.E.V._ s99- ..., -® —i— - - �� — • —�— — ?'ba� 9,n a�t �... �ge�'r.� l�ial� �rlr '- - — fi�r?? II '`V (-Q' - - _._,_ 1 WI i ' . r _ mc�esr�—1 am migi- IMI � - �N�, Sl9'_ i 1 —Y- _. .--1- ...w •1i-:-- .'_-1�[iii _ _ _ i�_ -1 - -- � 1_ — - pqt — 0 1Y003 3210A -" YYYYY9Y9Y1��••y��E !Mt'. --- »0 ice — i r �'�. ° 1 i� '6.1Mi! —'� la - - __ -�_=- _. __ '+rti-rl-iiw_!iG i��►_ — � r WsM I . ,____ �iMg �- AriasimMl==in ---7----i=s--=2,.... 1117,1.:Era=0 Ws , 'E. L_ t'• —®®--� �' m®Cl O�^ii � ` - ---»�i—�C IDS _ - - +� .+a:4aa�tl�wYY�Ylmr�iY9� - • • sue— t�3C.1� �-rJ.�.� �lTY9!t i i'f". i - -�' gar�iM czn= 1. I. :MISElimiEmnall SNVId „11U19—SV,S,N010VillN00 NO 035V8 �;, .� 13NNVH0 1tl010Ztldtl81 03NI1 3N01 „SONIMtl210 GJ003a» —G� I�.� ;al l 1 Mil rI � � Srt » oR Ia urmm 0.•.\ / RI ffi R ° .ITv1Efc -�Lai1 ,w"1-.sT'oOL vox i8 5w, oxm : \ / is unn lqu�n,usra� .,I,n,� ,,.a..°=s.n5»,n .\ \ /I p� CW w _ 1 a N ti ,.,b�.d , . �'� �' HOBO—A 03NI1 SSVa3 IO • // • .10 \ / _ _ �/# �' f'd;` ` l�,i til r \ .* 99� ..'u vn'e':"s yIt �lYy /• �- ti /- +.. , / 'spa onto sum OW..Olmor• inw wp 000200,1 Yfi 9Liv nrs w n z �*�. �9d f 4. a "i�" �I( ' j 3 a.¢ .m. rn , a w�i'q! , • o f / —� d �., 1 /f�/(,/�i Rom\\} � •i�� y 1 (/./ �o ' n - ; hiJ,;% �s�'l ..su- »N . ....,.,w.v» 1', \V/l/U N. �g1�i, x ��° A�!�, R �� r / %; l wn�',mmm',IE• f r v �r�+ '- ` ` fi�j". , A iF •r d e .n.�m..�,,n. �on•�.:m�v $. 1, v1i �, �.\ ' U'`,A�yrk / i i 1 '`"/. •:.a f .fr►4 .tk .- m i - :gyp e", 0600 »..In......,r.n y� VolQ ��\:`.()�-� /� * .,'`i+A"% °zj.S'\ f/ / 1.' feu �'" ,3Y-'7{4f ' /;_ � -py, ..e1 n�m.G.. ,1',�� \ J ,•7 si \(�\./� / '/ h Cl �. 1.�J1 \ _- is"t,,. - ---- w..meml.wmm» x..` d.J`5 5• ` / B - \\ /).;•,\�Ii . �� I ,�i�'\1••/\• `• ` ./� , i •;/ ` \ �% / y��2%n ra.. .G ,.-/ ` �- 1- — �f/�.t/+ ,, X+ -. -.. \ ,�-, 0 ' X. i ,\I I , ~ \` z, !`•+J i,,gr, n a °.,I°YR ./' .5 nlon.RS GLn . �,, ° ys-�(t mod` \ .•,,\ 1 �11 . dr4 1 1v 1 j \. --�m �-Oiii ��» /� r°� 9zi �� , "x, L. � __ �0 \ cti�� f ' + *1 I �a °• r�tR`+ /.sf� » o„.11101.10 n..�«.�. H r �! (G� • \ -'- p! I \ i �� 05 0 .i-. '`�_»... �/''7 �Inq'm:`.ma:'v..,i.n t �, s.cd( .I.rm s.ne...In B`3 st:.� :' \ .;1 \ \ / 1 �\ �� 1 j' � \_ .�s._` _,fi'-! � m.ou.x �j° '400"' ;�#' R�•...¢.nm n» "Q ...o.G �,A3°� \.�uwa•,\\ � II {' i i \'4 )J n_.._/ l _RI......'�.4= -- /cfl d,' a6 4, a > , .q.n.mw.o „ ;;II;III mev � ` \\ P"� `� � \ . St ��� °e"¢e�Io �"^"m "tlwo ITN TO - • l�/ �v` e; UM �,,... e+w::.. ,�J,nlln„/} �• '.\ 00-w .; ) ,m� ?`�;;;' a .ice�7►`���.,s4 n ., .. ., .,.,.R11- ' ( N �.u.�m Inn.vi a"�i�.°�m�. /n� `'� •i � R4°...In a:in° I 11� n•lam•yam`'/�j i o 0# mnw n ; �0,1,. l se ,,,,/,, , Innlli a."""�` , \� �. 1 i/ �- It/� a° ir „ra. m.a .`..I•. ,nmm ° ��� �. ` Q�;i► .� \ate IIW ins., ° ..nonce. lI p. ; , i g VYIX 3�MNIN-10 »,..,m,G m, t om _,_ 0 7 � •� y1 -,aun //' / a' -•, nl mniu°.mR•I.,n s.. !_ �/1/ ... �_�'��. `�,• O .0.M11h L1 ¢nllq tRwS,............-/—� '/ s SEC4.1 WED na lop p=.0S aG(�,INiNa.. I • am:um L.ati�'..v1.oiler.\ '.I 'I �••• I / 1—w-1"-.1� F au 7 IUP, Part 1 Section F: ReceivingPOTW name=> Laboratory Corporation South Burlington WWTP N name=> of America Effluent Limits and Monitoring Requirements Receiving POTW NPDES#=> NC0023876 IUP#_> 0066 Effective date for these Limits=> January 01,2022 Pipe#=> 01 The Permittee may discharge from this specific Expiration date for these Limits=> December 31,2026 40 CFR#=> N/A Pipe number according to these specific dates, if not applicable put N/A effluent limits, and monitoring requirements THE LIMITS ON THIS PAGE ARE,(Check one below): LIMITS for ENTIRE permit period => X INTERIM Limits for period#1 => INTERIM Limits for period#2 => FINAL Limits Page => Concentration Limits Mass Limits Monitoring Frequency Sample Required Collection Laboratory Monthly Monthly Method Detection Daily Max Average Units Daily Max Average Units By Industry By POTW (C or G) Level 1 Flow MGD Semi-annually Semi-annually 2 BOD Mg/I See Note Semi-annually Semi-annually C 2 _ 3 TSS See Note Semi-annually Semi-annually C 2 4 Temperature 50 Degree C Semi-annually Semi-annually G 5 PH 5-11 Standard Semi-annually Semi-annually G Units OTHER PARAMETERS;Please List Alphabetically 6 Chromium 0.10 Lbs/day Semi-annually Semi-annually C 0.005 mg/1 7 Copper 0.10 Lbs/day Semi-annually Semi-annually C 0.002 mg/1 8 Nickel 0.015 Lbs/day Semi-annually Semi-annually C 0.01 mg/1 9 Zinc 0.25 Lbs/day Semi-annually Semi-annually C 0.01 mg/1 10 Mercury 0.0011 Lbs/day Semi-annually Semi-annually C 0.0002mg/1 11 12 13 NOTE: The BOD and the TSS are to be surcharged if levels exceed 300 mg/1 and 150 mg/1 respectively. This permit may be reopened to include BOD limits when the POTW influent exceeds 75 percent of its design capacity. This will be determined by an updated POTW headwork's analysis. Monitoring frequency by industry should be completed within the second Quarter and fourth Quarter of the calendar year. The POTW will monitor within the first Quarter and third Quarter of the calendar year. Other parameters and limits are also subject to change as a result of updated headwork's information. a 5 Receivingt. t. POTW name=> South Burlington WWTP IU name=> Laboratory Corporation ��J�, Part 1 �ect�®n F: g of America Effluent Limits and Monitoring Requirements Receiving POTW NPDES#=> NC0023876 IUP#=> 0066 Effective date for these Limits=> January 01,2022 Pipe#=> 02 The Permittee may discharge from this specific Expiration date for these Limits=> December 31,2026 40 CFR#=> N/A Pipe number according to these specific dates, if not applicable put N/A effluent limits, and monitoring requirements THE LIMITS ON THIS PAGE ARE,(Check one below): LIMITS for ENTIRE permit period => X INTERIM Limits for period# 1 => INTERIM Limits for period#2 => FINAL Limits Page => Concentration Limits Mass Limits Monitoring Frequency Sample Required Collection Laboratory Monthly Monthly Method Detection Daily Max Average Units Daily Max Average Units _ By Industry By POTW (C or G) Level 1 Flow MGD Semi-annually Semi-annually 2 BOD Mg/1 See Note Semi-annually Semi-annually C 2 3 TSS See Note Semi-annually Semi-annually C 2 4 Temperature 50 Degree C Semi-annually Semi-annually G 5 PH 5-11 Standard Semi-annually Semi-annually G Units OTHER PARAMETERS;Please List Alphabetically _ 6 Chromium 0.10 Lbs/day Semi-annually Semi-annually C 0.005 mg/1 7 Copper 0.10 Lbs/day Semi-annually Semi-annually C 0.002 mg/1 8 Nickel 0.015 Lbs/day Semi-annually Semi-annually C 0.01 mg/1 9 Zinc 0.25 Lbs/day Semi-annually Semi-annually C 0.01 mg/1 10 Mercury 0.0004 Lbs/day Semi-annually Semi-annually C 0.0002mg/1 11 12 _ 13 NOTE: The BOD and the TSS are to be surcharged if levels exceed 300 mg/1 and 150 mg/1 respectively. This permit may be reopened to include BOD limits when the POTW influent exceeds 75 percent of its design capacity. This will be determined by an updated POTW headwork's analysis. Monitoring frequency by industry should be completed within the second Quarter and fourth Quarter of the calendar year. The POTW will monitor within the first Quarter and third Quarter of the calendar year. Other parameters and limits are also subject to change as a result of updated headwork's information. 6 All effluent entering the City of Burlington sewers at each discharge point shall meet the following restrictions: 1. Quarters run as follows: 1st—January 1-March 31: 2nd—April 1-June 30: 3rd-July 1-September 30: 4th—October 1-December 31. 2. Effluent limitations and monitoring requirements may be changed at any time during the permit period as deemed necessary by the City of Burlington. 3. The Industrial User shall monitor all results from an approved commercial lab. 4. Test procedures shall be in accordance with the EPA guidelines for specified parameters. 5. The City of Burlington may require approved sampling devices be installed at permittee's expense. 7 • Industrial User Pretreatment Permit (IUP) PARTI Specific Conditions G.) Definitions and Limit Page(s) notes: In addition to the defmitions in the City of Burlington Sewer Use Ordinance the following definitions and requirements apply: l. Composite Sample, alternative definition: A composite sample for the monitoring requirements of this IUP is the same as described above unless specifically defmed below as the automatic or manual collection of constant volume and constant time grab samples collected and composited according to the following criteria: Specific volume of each grab sample= 300 Milliliters Specific time interval between samples= 1 Hours Total duration of sample collection period= 24 Hours Total number of grab samples to be composited= 24 Samples 2. Daily Monitoring Frequency • Daily Monitoring Frequency as specified in this IUP shall mean each day of discharge. 3. Grab Sample Grab sample for the monitoring requirements of this IUP, is defmed as a single "dip and take" sample collected at a representative point in the discharge stream. 4. Instantaneous measurement An Instantaneous measurement for the monitoring requirements of this IUP is defined as a single reading, observation, or measurement. 8 Industrial User Pretreatment Permit (IUP) PART II General Conditions Outline of PART II, 1. Representative Sampling 16. Federal and/or State Laws 2. Reporting 17. Penalties 3. Test Procedures 18. Need to Halt or Reduce 4. Additional Monitoring by 19. Transferability Permittee 5. Duty to comply 20. Property Rights 6. Duty to Mitigate 21. Severability 7. Facilities Operation,Bypass 22. Modification,Revocation, Termination 8. Removed substances 23. Reapplication 9. Upset Conditions 24. Dilution Prohibition 10. Right of Entry 25. Reports of Changed Conditions 11. Availability of Records 26. Construction of pretreatment facilities 12. Duty to provide information 27. Reopener 13. Signatory Requirements 28. Categorical Reopener 14. Toxic Pollutants 29. General Prohibitive Standards 15. Civil and Criminal Liability 30. Reports of Potential Problems 1. Representative Sampling Samples and measurements taken as required herein shall be representative of the volume and nature of the monitored discharge. All samples shall be taken at the monitoring points specified in this permit and, unless otherwise specified, before the effluent joins or is diluted by any other wastestream, body of water, or substance. Monitoring points shall not be changed without notification to,and approval by,the permit issuing authority. 2. Reporting a.) Monitoring results obtained by the permittee shall be reported on forms specified by the Control Authority and/or Municipality,postmarked no later than the twentieth day of the month following the month in which the samples were taken. If no discharge occurs during a reporting period(herein defined as each calendar month)in which a sampling event was to have occurred,a form with the phrase"no discharge"shall be submitted. Copies of these and all other reports required herein shall be submitted to the Control Authority and/or Municipality and shall be sent to the following address: Robert C.Patterson,Jr.,P.E. Water Resources Director City of Burlington PO Box 1358 Burlington,NC 27216-1358 b.) If the sampling performed by the permittee indicates a violation,the permittee shall notify the Control Authority and/or Municipality within 24 hours of becoming aware of the violation. The permittee shall also repeat the sampling and analysis and submit the results of the repeat 9 Industrial User Pretreatment Permit (IUP) PART II General Conditions analysis to the Control Authority and/or Municipality within 30 days after becoming aware of the violation. 3. Test Procedures Test procedures for the analysis of pollutants shall be performed in accordance with the techniques prescribed in 40 CFR part 136 and amendments thereto unless specified otherwise in the monitoring conditions of this permit. 4. Additional Monitoring by Permittee If the permittee monitors any pollutant at the location(s) designated herein more frequently than required by this permit,using approved analytical methods as specified above,the results of such monitoring shall be submitted to the Control Authority and/or Municipality. The Control Authority and/or Municipality may require more frequent monitoring or the monitoring of other pollutants not required in this permit by written notification. 5. Duty to Comply The permittee must comply with all conditions of this permit.Any permit noncompliance constitutes a violation of the Control Authority and/or Municipality Sewer Use Ordinance and is grounds for possible enforcement action. 6: Duty to Mitigate - Prevention of Adverse Impact The permittee shall take all reasonable steps to minimize or prevent any discharge in violation of this permit,which has a reasonable likelihood of adversely affecting human health,the POTW,the waters receiving the POTW's discharge,or the environment. 7. Facilities Operation, Bypass The permittee shall at all times maintain in good working order and operate as efficiently as possible, all control facilities or systems installed or used by the permittee to achieve compliance with the terms and conditions of this permit. Bypass of treatment facilities is prohibited except when approved in advance by the Control Authority and/or Municipality. Bypass approval shall be given only when such bypass is in compliance with 40 CFR 403.17. 8. Removed Substances Solids,sludges,filter backwash,or other pollutants removed in the course of treatment or control of wastewaters shall be disposed of in a manner such as to prevent any pollutants from such materials from entering the sewer system. The permittee is responsible for assuring its compliance with any requirements regarding the generation,treatment,storage,and/or disposal of"Hazardous waste"as defined under the Federal Resource Conservation and Recovery Act. 9. Upset Conditions An "upset" means an exceptional incident in which there is an unintentional and temporary noncompliance with the effluent limitations of this permit because of factors beyond the reasonable control of the permittee. An upset does not include noncompliance to the extent caused by • operational error, improperly designed or inadequate treatment facilities, lack of preventative maintenance,or careless or improper operations. An upset may constitute an affirmative defense for action brought for the noncompliance. The permittee has the burden of proof to provide evidence and demonstrate that none of the factors specifically listed above were responsible for the noncompliance. 10 ti Industrial User Pretreatment Permit (IUP) PART II General Conditions 10. Right of Entry The permittee shall allow the staff of the State of North Carolina Department of Environmental Quality and Division of Water Resources, the Regional Administrator of the Environmental Protection Agency, the Control Authority and/or Municipality, and/or their authorized representatives,upon the presentation of credentials: 1. To enter upon the permittee's premises where a real or potential discharge is located or in which records are required to be kept under the terms and conditions of this permit; and 2. At reasonable times to have access to and copy records required to be kept under the terms and conditions of this permit;to inspect any monitoring equipment or monitoring method required in this permit;and to sample any discharge of pollutants. 11. Availability of Records and Reports The pennittee shall retain records of all monitoring information, including all calibration and maintenance records as well as copies of reports and information used to complete the application for this permit for at least three years. All records that pertain to matters that are subject to any type of enforcement action shall be retained and preserved by the permittee until all enforcement activities have concluded and all periods of limitation with respect to any and all appeals have expired. Except for data determined to be confidential under the Sewer Use Ordinance,all reports prepared in accordance with terms of this permit shall be available for public inspection at the Control Authority and/or Municipality. As required by the Sewer Use Ordinance,effluent data shall not be considered confidential. 12. Duty to Provide Information The permittee shall furnish to the Water Resources Director or his/her designees,within a reasonable time, any information which the Director, his/her designee, or the State of North Carolina Department of Environmental Quality and the Division of Water Resources may request to determine whether cause exists for modifying,revoking and reissuing,or terminating this permit or to determine compliance with this permit. The permittee shall also furnish,upon request,copies of records required to be kept by this permit. 13. Signatory Requirements All reports or information submitted pursuant to the requirements of this permit must be signed and certified by the Authorized Representative as defined under the Sewer Use Ordinance. If the designation of an Authorized Representative is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, or overall responsibility for environmental matters for the company, a new authorization satisfying the requirements of this section must be submitted to the Water Resources Director prior to or together with any reports to be signed by an authorized representative. 14. Toxic Pollutants If a toxic effluent standard or prohibition(including any schedule of compliance specified in such effluent standard or prohibition)is established under Section 307(a)of the Federal Clean Water Act for a toxic pollutant which is present in the discharge and such standard or prohibition is more stringent than any limitation for such pollutant in this permit,this permit may be revised or modified in accordance with the toxic effluent standard or prohibition and the permittee so notified. 11 Industrial User Pretreatment Permit (IUP) PART II General Conditions 15. Civil and Criminal Liability Nothing in this permit shall be construed to relieve the permittee from civil or criminal penalties for noncompliance. 16. Federal and/or State Laws Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the permittee from any responsibilities, liabilities, or penalties established pursuant to any applicable Federal and/or State law or regulation. 17. Penalties The Sewer Use Ordinance of the Control Authority and/or Municipality provides that any person who violates a permit condition is subject to a civil penalty not to exceed$25,000 dollars per day of such violation. Under state law, (NCGS 143-215.6B), under certain circumstances it is a crime to violate terms, conditions, or requirements of pretreatment permits. It is a crime to knowingly make any false statement,representation,or certification in any record or other document submitted or required to be maintained under this permit, including monitoring reports or reports of compliance or noncompliance. These crimes are enforced at the prosecutorial discretion of the local District Attorney. 18. Need to Halt or Reduce not a Defense It shall not be a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity to maintain compliance with the conditions of the permit. 19. Transferability This permit shall not be reassigned or transferred or sold to a new owner, new user, different premises,or a new or changed operation without approval of the Town. 20. Property Rights This permit does not convey any property rights in either real or personal property,or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement of Federal,State or local laws or regulations. 21. Severability The provisions of this permit are severable and,if any provision of this permit or the application of any provision of this permit to any circumstance is held invalid,the application of such provision to other circumstances and the remainder of this permit shall not be affected thereby. 22. Permit Modification, Revocation, Termination This permit may be modified,revoked and reissued or terminated with cause in accordance to the requirements of the Control Authority and/or Municipality Sewer Use Ordinance and North Carolina General Statute or implementing regulations. 23. Re-Application for Permit Renewal 12 Industrial User Pretreatment Permit (IUP) PART II General Conditions The permittee is responsible for filing an application for reissuance of this permit at least 180 days prior to its expiration date. 24. Dilution Prohibition Thepermittee shall not increase the use ofpotable orprocess water or in anyother wayattempt to P dilute the discharge as a partial or complete substitute for adequate treatment to achieve compliance with the limitations contained in this permit. 25. Reports of Changed Conditions The permittee shall give notice to the Control Authority and/or Municipality of any planned significant changes to the permittee's operations or system which might alter the nature,quality,or volume of its wastewater at least 180 days before the change. The permittee shall not begin the changes until receiving written approval from the Control Authority and/or Municipality. Also see Part II,30 below for additional reporting requirements for spill/slug issues. Significant changes may include but are not limited to (a) Increases or decreases to production; (b) Increases in discharge of previously reported pollutants; (c) Discharge of pollutants not previously reported to the Control Authority and/or Municipality; (d) New or changed product lines; (e) New or changed manufacturing processes and/or chemicals;or (f) New or changed customers. 26. Construction No construction of pretreatment facilities or additions thereto shall be begun until Final Plans and Specifications have been submitted to the Control Authority and/or Municipality and written approval and an Authorization to Construct(A to C)have been issued. 27. Reopener The permit shall be modified or,alternatively,revoked and reissued to comply with any applicable effluent standard or limitation for the control of any pollutant shown to contribute to toxicity of the WWTP effluent or any pollutant that is otherwise limited by the POTW discharge permit. The permit as modified or reissued under this paragraph may also contain any other requirements of State or Federal pretreatment regulations then applicable. 28. Categorical Reopener This permit shall be modified,or alternatively,revoked and reissued,to comply with any applicable effluent standard or limitation issued or approved under Sections 302(b)(2)(C)and(D),304(b)(2), and 307(a)(2)of the Clean Water Act,if the effluent standard or limitation so issued or approved: 1.) Contains different conditions or is otherwise more stringent than any effluent limitation in this permit;or 2.) Controls any pollutant not limited in this permit. The permit as modified or reissued under this paragraph shall also contain any other requirements of the Act then applicable. 29. General Prohibitive Standards The permittee shall comply with the general prohibitive discharge standards in 40 CFR 403.5 (a) and(b)of the Federal pretreatment regulations. 13 Industrial User Pretreatment Permit (HIP) PART II General Conditions 30. Potential Problems The permittee shall provide protection from accidental and slug discharges of prohibited materials and other substances regulated by this permit. The permittee shall also notify the POTW immediately of any changes at its facility affecting the potential for spills and other accidental discharge,discharge of a non-routine, episodic nature, a non-customary batch discharge, or a slug load as defined in the Sewer Use Ordinance. Additionally, the permittee shall notify by telephone the Control Authority and/or Municipality immediately of all discharges that could cause problems to the POTW including any slug loadings as defined in the Sewer Use Ordinance. If the permittee experiences such a discharge,they shall inform the Control Authority and/or Municipality immediately upon the first awareness of the commencement of the discharge. Notification shall include location of the discharge,type of waste, concentration and volume if known and corrective actions taken by the permittee. A written follow- up report thereof shall be filed by the permittee within five(5)days,unless waived by the Control Authority and/or Municipality. 14 Industrial User Pretreatment Permit (IUP) PART III Special Conditions 1. Slug/Spill Control Measures The permittee shall provide protection from accidental and slug discharges of prohibited materials and other substances regulated by this permit. The permittee shall develop a written slug/spill control plan and submit it to the Control Authority on or before June 15, 2022 for the approval by the Control Authority. The plan shall include,but is not limited to: • Description of discharge practices, including non-routine batch discharges; • Description of stored chemicals; • Procedures for immediately notifying the POTW of slug discharges that would cause a violation of 40 CFR 403.5(b),with procedures for follow-up notification within 5 days; • And if necessary, procedures to prevent adverse impact from accidental spills, including inspection and maintenance of storage areas,handling and transfer of materials, loading and unloading operations,control of plant site run-off, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants (including solvents), and/or measures and equipment for emergency response. 2. Sludge Management Plan Ninety days prior to the initial disposal of sludge generated by any pretreatment facility, the permittee shall submit a sludge management plan to the Control Authority. 3. Flow Measurement Requirements The permittee shall record the water meter reading providing water to the facility at the beginning and end of each composite sample collection time period,convert this to an estimate of the daily discharge flow for each pipe, and report this value on the discharge monitoring report form. If the water meter is unreadable, the control authority may use water consumption reports for estimation of the daily discharge flow for each pipe, and report this value on the discharge monitoring report form. 4. Certified Laboratory Analysis Pollutant analysis shall be performed by a State of North Carolina Department of Environmental Quality and the Division of Water Resources Certified Laboratory that is certified in the analysis of the pollutant in wastewater. 15 IUP Synopsis A. IUP Basic Information Receiving POTW name: POTW NPDES#: South Burlington Wastewater Treatment NC0023876 Plant IUP name: IUP Number. Laboratory Corporation of America 0066 IUP Effective date: Pipe Numbers,list all regulated pipes: January 01,2022 01,02 IUP expiration date: IUP 40 CFR#,if applicable: December 31,2026 N/A B. IUP Survey&Application form Attach a completed copy of the Industrial User Wastewater Survey & Application Form(see appendix 6-A) C. IU Inspection form Attach a copy of an Industrial User Inspection Form(see chapter 7) completed by the Control Authority within the past 12 months. D. RATIONALE FOR LIMITATIONS: As listed on the IUP Limits Page(s),PART I, Section F of the IUP. RATIONALE#1: Review of IU Monitoring Data,with no Over Allocation situation: The following pollutants were assigned numerical limits in this IUP based on a review of monitoring data for the permittee to determine what ranges of concentrations are currently being discharged. To account for sample variability a factor was applied to the monitoring data to determine the permit limit. Permit limits assigned by the Local IUP Control Authority cannot result in an Over Allocation situation for any pollutants. Chromium 0.20 lbs/day Copper 0.20 lbs/day Nickel 0.03 lbs/day Zinc 0.50 lbs/day Mercury 0.0015 lbs/day 1 SIU INSPECTION FORM 2020 , Name Of Industry: Labcorp IUP # 0066 Address Of Industry: 1447 York Court IUP Expiration Date: ,1„,_c .. l d Burlington,NC 27215 12/31/2021 , kl �W� Q'�/f VE'�z`= Industry Representatives: Title renewed /e �� Adrian Ridley and ecalia4 POTW Representatives: Title Kristy King Industrial Pretreatment Specialist Date Of Inspection: //— 7c/-2070 Time Of Inspection: 0 ( 43111 Purpose of Inspection: Annual X Other(Describe) POTW to which IU discharges SBWWTP NPDES# NC0023876 Is SIU currently in SNC? No If yes,for what? PART I-INITIAL INTERVIEW Has anything changed since the last inspection or IUP application in the following: COMMENTS Product YES fit", Raw materials used YES/4. r Manufacturing processes YES/di Categorical, if applicable YF S/NO Production rate 6 S/NO II' dae y-a Cc jid Number of employees eV/NO 1- 2000 Number of shifts YES/ 10 2 el/7 / 3 C,5 Comments: PART II - PLANT TOUR- Visit all areas where wastewater is generated or where there are drains to the POTW. Plant Tour Section A- PRODUCTION AND STORAGE AREAS 1. re there floor drains in the production area? (�E /NO Where do they go? 5S f100r c�r�.1n� . ew►�rc`�cincq - cu IS 2. Are production areas diked,cont.'I ed,or otherwise constructed in such a way as to prevent harm to the WWTP, especially from spills or slugs? /NO Comments: 3. Are there floor drains in the storage area? YES(SO) Where do they go? 4. Are storage tanks and areas diked,contained,or otherwise constructed in such a way as to prevent harm to the WWTP,especially from spills or slugs? YE /NO Comments: 5. Are process and storage tanks and pipes labeled? /NO 6. How are off-spec raw materials,and products disposed of? re'fttrn it) VeYtriOr 7. When is the production area cleaned? CIO,. Ili 8. Is the wastewater from cleaning the production are discharged to the POTW? YE3/NO 9. What non-process wastewaters are discharged to POTW? (b viir ± C_ Comments: PART II - Plant Tour Section B - PRETREATMENT SYSTEM Ask the operator to describe pretreatment system. Title: SIU Inpsection Form File name: COMP.INSP App 7-D Revision data: August 1,1994 Page 1 • SIU INSPECTION FORM 2020 1. Does operator seem knowledgeable about the system? YES/NO Comments: 2. Are all units operational? YES/NO / //�_ 3. How often does operator/maintenance person check system? /l/ /j'( 4. Is there an operator for each shift? YES/NO 5. How and when is sludge disposed of? 6. Is there a schedule for preventative maintenance? YES/NO Comments: PART II - Plant Tour Section C - SAMPLING POINT(S)AND FLOW MEASUREMENT (Collect a sample if desired.) 1. Does an outside lab complete sampling? /NO If yes,name of lab. ewe, fl L'f"i ' 2. If industry completes sampling,ask the industry representative to describe sampling procedures. Comments: 3. Is flow measurement equipment operational? YE /NO Comments: 'P ter- y tt 4 4. Is there a calibration log for the flow meter? (VE /NO Comments: C'n Ili ttAVI (S 3;_isfe V l Comments: PART III - EXIT INTERVIEW Review monitoring records and • .•er SIU records required by IUP. 1. Are files well organized? "/NO Comments: 2. Are sample collection/chain-of-custody forms filled out properly? CVES)/NO Comments: 3. Do results in files agree with reports sent to POTW? eival NO Comments: 4. Who has authority to shut down production should a spill or slug discharge occur? 14;Sy Nye, gr.. n Norwell , 71rirzeJcr'V 5. How does SIU inform employees of whom to call at POTW in case of spill/slug? 5 pi II r)l 2 l l�o act ; ►/Vlel—gei(iC'. l2es nnS�' .,(e�- ✓1 1_ If shtg/spill plan is already required y POT review Procedures. 6. Is SIU implementing slug/spill plan? EY NO Comments: 1 —"VtD de Comments: INSPECTION RESULTS �� � 1 Slug/Spill Control Plan Needed? YES V'�� e Comments,Required Or Recommended Actions: Signature Of Inspectors) Date: //-`7 G%-2-0 Signature of SUI Representative ,�,tw 4/ Date: ;(-;q-,i lk Title: SIU Inpsection Form File name: COMP.INSP App 7-D Revision data: August 1, 1994 Page 2 Industrial User Wastewater Survey & Permit Application COVER PAGE Company Name: Labcorp Name of responsible person on site at the facility authorized Name of alternative on site person familiar with the day to to represent the company in official dealings with the Sewer day operations, environmental permitting requirements, Authority and/or the City. monitoring,record keeping,and data management.. Name/Title: Dr.Mindy NyeNP Years with firm: 16 Name/Title: Adrian Ridley/Regional Years with firm:2 EHS Mgr Phone#336-264-5412 Fax# Phone#: 336-380-6555 Fax# Physical street address of facility Official mailing address,if different. Note if same. 1447 York Court Same City: Burlington State: NC Zip: 27215 City State Zip The information provided by you on this questionnaire serves two functions: 1. The information is used to determine if your facility needs an Industrial User Pretreatment Permit(IUP)for the discharge of wastewater to the local sewer. 2. If an Industrial User Pretreatment Permit (IUP) is required, this survey serves as the application for an Industrial User Pretreatment Permit(IUP). Requests for confidential treatment of information provided on this form shall be governed by procedures specified in 40 CFR Part 2. In accordance with Title 40 of the Code of Federal Regulations Part 403, Section 403.14 and the Local Sewer Use Ordinance (SUO), information and data provided in this questionnaire which identifies the content, volume and frequency of discharge shall be available to the public without restriction. This is to be signed by an authorized official of your firm,as defined in the Local Sewer Use Ordinance or the NC Model Sewer Use Ordinance,Section 1.2,after completion of this form. I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based upon my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and/or imprisonment for knowing violations. O( ia 1 1241.1 Signature of Authorize Representative Date listed above (seal if applicable) Title: IU Wastewater Survey&Permit Application File name: I:\File\City of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 1 of 198 Industrial User Wastewater Survey & Permit Application 1. Provide a brief narrative description of the type of business, manufacturing processes, or service activities your firm conducts at this site. The Powell building is a biomedical diagnostic testing facility and office building. The DNA/Identity building conducts paternity testing. The Warehouse has rack storage of laboratory supplies. Labcorp provides medical laboratory tests and services through a national network of primary clinical and specialty testing laboratories. Labcorp processes approximately 470,000 specimen tests each day. 2. List the primary products produced at this facility: No product manufacturing. Only specimen diagnostic testing and results. 3. List raw materials and process additives used: N/A 4. Are biocides added to any water discharged to the POTW, if yes describe: Yes No X 5. Describe weekly production schedule, including shifts worked per day, employees per shift, and primary operation during shift. The entire campus (except the Warehouse) is open 24 hours a day 7 days a week with three shifts. The warehouse is open Monday through Friday 8:00 am to 5:00 pm. Total employees: 2,000 1st Shift: 1,000 2nd Shift: 500 3rd Shift: 500 6. Production process is: N/A Check, if all continuous Check, if all batch If both please enter, % continuous= % %Batch= Title: IU Wastewater Survey&Permit Application File name: I:\File\City of Burlington Waste Water\Permit Renewal\Industrrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 2 of 198 Industrial User Wastewater Survey & Permit Application 7. Does production vary significantly(+- 20 %) by season. Describe. Yes No X 8. Are any significant (+- 20 %) changes in production that will affect wastewater discharge expected in the next 5 years. If yes,please describe. Yes No X 9. List all current waste haulers. Give name, address, phone numbers, volume and materials hauled off. Stericycle Clean Earth 4403 Republic Ct NW, 1220 Corporate Parkway Concord,NC 28027 Raleigh,NC 27610 Phone: 331-300-3238 Phone: 678-822-9963 10. Attach a copy of laboratory analyses performed in the last year on the wastewater discharge(s) from your facilities. Summarize data on the attached Data Summary Form. Attached 11. Attach sketch or schematic showing sampling points and all connections to the sewer. Attached 12. Complete the Wastewater Pollutants Checklist attached to this Survey. Completed Title: IU Wastewater Survey&Permit Application File name: I:\File\city of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 3 of 198 Industrial User Wastewater Survey & Permit Application 13. Do you have,or have you ever applied for, been issued, or been denied an NPDES permit to discharge to the surface waters or storm sewers of North Carolina? If yes,list all other NPDES permits,permit numbers,dates,and names used to apply for them, or reason denied. If yes: Permit,#,date,applicant name Yes If yes: Permit,#,date,applicant name No X 14. Do you have, or have you ever applied for or been issued an Industrial User Pretreatment Permit (IUP) to discharge wastewater to the sewer collection system. If yes,list all other IUP permits,permit numbers,dates, and names used to apply for them. If yes: Permit,#,date,applicant name Yes X Waste Water Discharge to the South Burlington Waste Water Treatment Plant. IUP# 0066. Issued 01/01/2017. Expires 12/31/2021. Laboratory Corporation of America If yes: Permit,#,date,applicant name No 15. Do you have, or have you ever applied for or been issued any other Environmental Permits (for example; air, RCRA, groundwater, stormwater,general,Non-Discharge,septic tank,etc.). If yes,list all other permits,permit numbers, dates, and names used to apply for them. If yes: Permit type,#,date,applicant name Yes X Hazardous Waste (LQG), EPA Generator ID#NCD048183768 If yes: Permit type,#,date,applicant name No If yes: Permit type,#,date,applicant name 16. Is a Spill Prevention Control and Countermeasure(SPCC)Plan prepared for this facility? Yes X No 17. Is a Spill /Slug Control Plan required by the POTW, prepared for this facility? Yes X No Title: IU Wastewater Survey&Permit Application File name: I:\File\City of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 4 of 198 Industrial User Wastewater Survey & Permit Application 18. Do you have any underground storage tanks at your facility? If yes, list contents and volume of each tank. Yes No X 19. Do you have any above ground storage tanks at your facility? If yes, for each tank, list the contents, volume, whether the tank has any spill prevention or containment devices, such as dikes, and procedures for draining any containment devices. Yes X #of Tanks 7 (Diesel Fuel Tanks) No Title: IU Wastewater Survey&Permit Application File name: I:\File\city of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 5 of 198 Industrial User Wastewater Survey & Permit Application PART II, Water Supply, Use, & Disposal Worksheet: Water Used for: Water Avg. Max. M E Disposal Avg. Max. M E gal/day gal/day e st gal/day gal/day e st Source(s) a i Method(s) a i s m s m u at u at re e re e d d d d (see Source List below) X (see Disposal List below) 1. Process water 1-City 29,072 2-Sanitary Sewer w/o Pre 29,072 X 2. Washdown water 3. Water into product 4. Air Quality Permitted units 5. Domestic-toilets, drinking, cafe 1-City 20,000 X 2-Sanitary Sewer w/o Pre 20,000 X 6. Cooling water, Process NON-Contact 7. Boiler/Cooling tower blowdown 8. Cooling water,HVAC 9. Other: Totals=> 49,072 Totals => 49,072 Typical Water Sources: Possible Water Disposal Methods 1. City/Public supply 1. Sanitary sewer,with pretreatment 2. Private wells,drinking 2. Sanitary sewer,without pretreatment 3. Groundwater remediation wells 3. Storm sewer 4. Private ponds 4. Surface waters of NC 5. Surface waters of NC,please identify 5. Evaporation 6. Include others if applicable 6. Land applied 7. To groundwater 8. Septic Tank 9. Waste Haulers (identify) 10. Water into Product Title: IU Wastewater Survey&Permit Application File name: I:\File\city of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 6 of 198 a 11. Include others, if applicable • • Title: IU Wastewater Survey&Permit Application File name: I:\File\city of Burlington Waste Water\Permit RenewalVIndustrial Wastewater Survey IUP Peituit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 7 of 198 • PART III, PRETREATMENT FACILITIES: • Are there any pretreatment devices or processes used for treating wastewater before being discharged to the sewer? Check all that are present, and describe. No pretreatment facilities=> X 1. Flow equalization Aerated equalization=> NON-Aerated equalization=> Total volume of equalization (million gal.)=> 2. Activated Carbon Yes No X Describe any, if present. 3. Activated Sludge Yes No X 4. Air Stripping Yes No X 5. Centrifugation Yes No X 6. Chemical Precipitation Yes No X 7. Chlorination Yes No X 8. Cyanide Destruction Yes No X 9. Cyclone Yes No X 10. Dissolved Air Floatation Yes No X 11. Filtration Yes No X 12. Flocculation Yes No X 13. Grease Trap Yes No X 14. Grit Removal Yes No X 15. Ion Exchange Yes No X 16. Neutralize,pH adjust Yes No X 17. Other Biological Treatment Yes No X 18. Ozonation Yes No X 19. Reverse Osmosis Yes No X 20. Screening Yes No X 21. Sedimentation Yes No X 22. Septic Tank Yes No X 23. Silver Recovery Yes No X 24. Solvent Separation Yes No X 25. Spill protection Yes No X List any others. Title: IU Wastewater Survey&Permit Application File name: I:\File\City of Burlington Waste Water\Perrnit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 8 of 198 PART IV, CATEGORICAL INFORMATION: 1. When were operations started at this facility Facility startup date 1978 2. List all Standard Industrial Classification(SIC) codes for your facility. These may be found on State Unemployment forms,tax forms, accounting records, or from the Chamber of Commerce. 621511 3. Has this facility ever been considered a Categorical Industrial User (CIU) as described by the Code of Federal Regulations (40 CFR)? If yes, give complete 40 CFR number=> No X 4. Are any other facilities owned and/or operated by your company permitted as Categorical Industrial Users (CIUs) as described by the Code of Federal Regulations (40 CFR)? If yes please give name(s), location, and 40 CFR number. Yes No X Title: IU Wastewater Survey&Permit Application File name: 1:\File\City of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 9 of 198 PART IV, CATEGORICAL INFORMATION: (continued) 5. Check any activities listed below that are performed at your facility: N/A Check 40 Industrial Activity Check 40 Industrial Activity below CFR# below CFR# 467 Aluminum Forming 432 Meat products 427 Asbestos Manufacturing 433 Metal finishing 461 Battery Manufacturing 464 Metal molding and casting 431 Builders paper&board mills 436 Mineral mining and processing 407 Canned&preserved fruits&veg. 471 Nonferrous Metal,Form&Powders 408 Canned&preserved seafood 421 Nonferrous Metals Manufacturing 458 Carbon black Manufacturing 414 OCPSF,Organic Chemicals,Plastics, 411 Cement Manufacturing &Synthetic Fiber Manufacturing 437 Centralized Waste Treatment 435 Oil&gas extraction 434 Coal Mining 440 Ore mining and dressing 465 Coil Coating 446 Paint formulating 468 Copper Forming 443 Paving and roofmg materials Mfg. 405 Dairy products processing 455 Pesticide Manufacturing 469 Electrical,electronic components 419 Petroleum Refining 413 Electroplating 439 Pharmaceutical Manufacturing 457 Explosives Manufacturing 422 Phosphate Manufacturing 412 Feedlots 459 Photographic supplies 424 Ferro allay Manufacturing 463 Plastics molding and forming 418 Fertilizer Manufacturing 466 Porcelain enameling 464 Foundries,Metal Mold&Casting 430 Pulp,paper,and paperboard 426 Glass Manufacturing 428 Rubber Manufacturing 406 Grain mills 417 Soap&Detergent Manufacturing 454 Gum&Wood Chemicals Mfg. 423 Steam Electric power Generation 460 Hospitals 409 Sugar processing 447 Ink formulating 410 Textile Mills 415 Inorganic chemical Manufacturing 429 Timber products processing 420 Iron&Steel Manufacturing 442 Transportation Equipment Cleaning 425 Leather Tanning&Finishing Others Title: IU Wastewater Survey&Permit Application File name: I:\File\City of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 10 of 198 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (mg/1) Acid Extractable Organics 2-Chlorophenol 34586 X X 2,4-Dichlorophenol 34601 X X 2,4-Dimethylphenol 34606 X X 2,4-Dinitrophenol 34616 X X 2-Methyl-4,6-dinitrophenol 34657 X X 4-Chloro-3-methylphenol 34452 X X 2-Nitrophenol 34591 X X 4-Nitrophenol 34646 X X Pentachlorophenol 39032 X X Phenol 34694 X X 2,4,6-Trichlorophenol 34621 X X Base Neutral Organics 1,2,4-Trichlorobenzene 34551 X X 1,2-Dichlorobenzene 34536 X X 1,2-Diphenylhydrazine 34346 X X 1,3-Dichlorobenzene 34566 X X 1,4-Dichlorobenzene 34571 X X 2,4-Dinitrotoluene 34611 X X 2,6-Dinitrotoluene 34626 X X 2-Chloronaphthalene 34581 X X 3,3-Dichlorobenzidine 34631 X X 4-Bromophenyl phenyl ether 34636 X X 4-Chlorophenyl phenyl ether 34641 X X Acenaphthene 03405 X X Acenaphthylene 34200 X X Anthracene 34220 X X Benzidine 39120 X X Benzo(a)anthracene 34526 X X Benzo(a)pyrene 34247 X X Benzo(b)fluoranthene 34230 X X Benzo(ghi)perylene 34521 X X Benzo(k)fluoranthene 34242 X X Bis(2-chloroethoxy)methane 34278 X X Bis(2-chloroethyl)ether 34273 X X Bis(2-chloroisopropyl) ether 34283 X X Bis(2-ethylhexyl)phthalate 39100 X X Butyl benzyl phthalate 34292 X X Chrysene 34320 X X Di-n-butyl phthalate 39110 X X Title: IU Wastewater Survey&Permit Application File name: I:\File\City of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 11 of 198 ti • Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (mg/1) Base Neutral Organics (continued) Di-n-octyl phthalate 34596 X X Dibenzo (a,h) anthracene 34556 X X Diethyl phthalate 34336 X X Dimethyl phthalate 34341 X X Fluoranthene 34376 X X Fluorene 34381 X X Hexachlorobenzene 39700 X X Hexachlorobutadiene 34391 X X Hexachlorocyclopentadiene 34386 X X Hexachloroethane 34396 X X Indeno(1,2,3-cd)pyrene 34403 X X Isophorone 34408 X X N-nitroso-di-n-propylamine 34428 X X N-nitrosodimethylamine 34438 X X N-nitrosodiphenylamine 34433 X X Naphthalene 34696 X X Nitrobenzene 34447 X X Phenanthrene 34461 X X Pyrene 34469 X X Metals Poe, 462. Aluminum 01104 X X Antimony 01097 X X Arsenic 01002 X X Beryllium 01012 X X Cadmium 01027 X X Chromium 01034 X X ab30/o 01(09 Copper 01042 X X 0,0 RA10.n? Lead 01051 X X Mercury 71900 X X Molybdenum 01062 1 X Nickel 01067 X 01147 %C- L1!' <'WI Selenium X X Silver 01077 X X Thalium 00982 X X Zinc 01092 X X OM I Z/ cfr% Title: IU Wastewater Survey&Permit Application File name: 1:\File\City of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 12 of 198 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (mg/1) Other Inorganics Barium 01007 X X Chloride 00940 X X Cyanide 00720 X X Fluoride 00951 X X Purgeable Volatile Organics 1,1,1-Trichloroethane 34506 X X 1,1,2,2-Tetrachloroethane 34516 X X 1,1,2-Trichloroethane 34511 X X 1,1-Dichloroethane 34496 X X 1,1-Dichloroethylene 34501 X X 1,2-Dichloroethane 34531 X X 1,2-Dichloropropane 34541 X X 2-Chloroethyl vinyl ether 34576 X X Acrolein 34210 X X Acrylonitrile 34215 X X Benzene 34030 X X Bromodichloromethane 32101 X X Bromoform 32104 X X Bromomethane 34413 X X Carbon tetrachloride 32102 X X Chlorobenzene 34301 X X Chloroethane 34311 X X Chloroform 32106 X X Chloromethane 34418 X X cis 1,3-Dichloropropene 34704 X X Dibromochloromethane 32105 X X Ethylbenzene 34371 X X Methylene chloride 34423 X X Tetrachloroethylene 34475 X X Toluene 34010 X X trans 1,3-Dichloropropene 34699 X X trans-1,2-Dichloroethylene 34546 X X Trichloroethylene 39180 X X Trichlorofluoromethane 34488 X X Vinyl chloride 39175 X X Others Xylene X X Title: IU Wastewater Survey&Permit Application File name: I:\File\City of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 13 of 198 Data Summary Form e. �� y, d ,t'1 1 F <= Receiving POTW ,AtC.FE;,`(`,-L,357(c:j <= Receiving NPDES # L..ct e,c,er DO/ <= Specific Sample Location! At 00(v6 i.e., Give IU Name, IUP#, and/or pipe# BOD TSS Ammonia Lab => Laboratory performing analysis => MDL => Laboratory Method Detection Limits => Notes => Notes => Q = Flow Sample Date Notes about Sample M=Metered Conc. Results Conc. Results Conc. Results ID, or Sample E=Estimated from Lab from Lab from Lab Count Collected mgd gal/day <? mg/1 <? mg/1 <? mg/1 1 ;/.73/1 6 L,. o ;:2 3/5 ql2 2 PY 3/2e 1. D'-i 2622. 3.7 2 3 3/!Y /J E ,:_ 02 5 zilo 6;, /.y/ 4 Vj �c.2l E ".-.- D 2,5 /o J *F7, 3 5 6 7 8 9 10 11 12 etc TNS => Total number of samples => Max. value => Maximum data value (mg/1) => 44 , 9/.Z Avg. (use 1/2 BDL) _> Avg. data value, Include BDL values as 1/2 detection limit=> /6,r , cf Data Summary Form Title: IU Wastewater Survey & Permit Application File name: C:\Users\klking\Documents\PRETREATMENT\Blank form\Permit Application Long form.doc Revision date: 12/30/97 Page 13 of 188 S, L,)&YI ' <= Receiving POTW , /1/C 60 Z 3 7 <= Receiving NPDES # L bG,v�_ 00 I <= Specific Sample Location! (7 6i e-, i.e., Give IU Name, IUP#, and/or pipe # Arsenic Copper Chromium Cadmium COD Copper Lab => _ MDL => Notes => Sample Date Sample Conc. Results Conc. Results Conc. Results Conc. Results • Conc. Results Conc. Results ID or Collected from Lab from Lab from Lab from Lab from Lab from Lab Count <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 1 7/z3/mac r, C,1/7 z 67, /C e, 2 /)//3/2c zO G%, o:3 ' 4. c�, 00 Ci - 3 3// /2oZi C',- :i G, UCy 7/ 5 6 7 _ 8 9 10 11 12 etc TNS => `f 4 Max. Value => r (.-,cf 77 C. /C>G) Avg. (usel/2 BDL) _> C. C36,/ r. C'13C Data Summary Form Title: IU Wastewater Survey & Permit Application File name: C:\Users\klking\Documents\PRETREATMENT\Blank form\Permit Application Long form.doc Revision date: 12/30/97 Page 14 of 188 c_i.0 (.,L,,;7i'P <= Receiving POTW /t.)C',CAD L 3 3-7(p <= Receiving NPDES # (.try ,corC hni <= Specific Sample Location! ./ C)C~Cr, i.e., Give IU Name, IUP#, and/or pipe # Cyanide Lead Mercury Nickel Silver Zinc Lab => MDL => Notes => Sample Date Sample Conc. Results Conc.Results Conc. Results Conc. Results Cone. Results Cone. Results ID or Collected from Lab from Lab from Lab from Lab from Lab from Lab Count <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 1 -7/23/wze\ U.00..b`� o: 097 2 /D//3/zcze> L b OO5 6, n 3 ; /V2i Z./ D. 0033 O. II 4 51 2rj L O. 05 o, 19 5 / � 6 7 8 9 10 11 12 etc TNS => q y Max. Value => C.:`, C 7.`J 0 /Gj Avg. (use l/2 BDL) => _ 0U.1 F) //2 Data Summary Form Title: IU Wastewater Survey & Permit Application , File name: C:\Users\ldking\Documents\PRETREATMENT\Blank form\Permit Application Long form.doc Revision date: 12/30/97 Page 15 of 188 Data Summary Form r4 <= Receiving POTW f C , 5 3 - ; <= Receiving NPDES # L ; laces, . <= Specific Sample Location! #i („Cp i.e., Give IU Name, IUP#, and/or pipe# BOD TSS Ammonia Lab => Laboratory performing analysis => MDL => Laboratory Method Detection Limits => Notes => Notes => Q = Flow Sample Date Notes about Sample M=Metered Conc. Results Conc. Results Conc. Results ID, or Sample E=Estimated from Lab from Lab from Lab Count Collected mgd gal/day <? mg/1 <? mg/l <? mg/1 1 G) 25 Lc /60 2 / c,t//4 C: Di/ 3 7b ill, 3 _3/ 'zc� . 4'0V _ z 21/ //i 4 el/ �7E� p.(ye/ s�4 3z, 1/ 5 6 7 8 9 10 11 12 etc TNS => Total number of samples => y !L� Max. value => Maximum data value (mg/1) => ?� 66 Avg. (use 1/2 BDL) _> Avg. data value,Include BDL values as 1/2 detection limit=> 55/,5'76 3v17.5 Data Summary Form Title: IU Wastewater Survey & Permit Application File name: C:\Users\klking\Documents\PRETREATMENT\Blank form\Permit Application Long form.doc Revision date: 12/30/97 Page 13 of 188 3 6 Lt.)( )rp <= Receiving POTW i vD `3 �(4, <= Receiving NPDES # Lc<br2 O02 <= Specific Sample Location! . WG i.e., Give IU Name, IUP#, and/or pipe# Arsenic Copper Chromium Cadmium COD Copper Lab => MDL => Notes => Sample Date Sample Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results ID or Collected from Lab from Lab from Lab from Lab from Lab from Lab Count <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 1 7/2..- 2ozc ..� /,3(-7 ' `i , O55 7 2 /0//-3 z© r1 n5c7 , °Q S _ '/ 3 �. 1//57/202./ t> C�lv7`-/ U, 0o7 4 5"/2/. i( O. oSy e c05 5 6 7 8 9 10 _ 11 12 etc TNS => 4 7 Max. Value => ti. t 3 j C.).dS.7 7 Avg. (use1/2 BDL) _> ; C.)..0 O. CV 6,, 1 Data Summary Form Title: IU Wastewater Survey & Permit Application , File name: C:\Users\ldking\Documents\PRETREATM NT\Blank form\Permit Application Long form.doc Revision date: 12/30/97 Page 14 of 188 t';L.01z i P <= Receiving POTW A?©C> 7.3T <= Receiving NPDES # Alec v C7c 2 <= Specific Sample Location! (12e0 i.e., Give IU Name, IUP#, and/or pipe # Cyanide Lead Mercury Nickel Silver Zinc Lab => MDL => Notes => Sample Date Sample Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results ID or Collected from Lab from Lab from Lab from Lab from Lab from Lab Count <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 1 -i/23/z`c ._0: 3 0, 1361 2 C 1rz--- L C7 (DO 5 C.?i Gx-� _: 3 is2 o U0-7Z C?, C�we 4 4(`3 , �2� , 0O,5 C_�, DC,05 5 6 7 8 9 10 11 12 etc TNS => Max. Value => rj_3 y 3 C7 i '1 Avg. (usel/2 BDL) _> ( 6. t,,t5 Data Summary Form Title: IU Wastewater Survey & Permit Application File name: C:\Users\klking\Documents\PRETREATMENT\Blank form\Permit Application Long form.doc Revision date: 12/30/97 Page 15 of 188 Industrial User Wastewater Survey & Permit Application Part V, Waste Reduction Information: State Pretreatment Rule 15A NCAC 2H.0916 (c)(1)(M) requires Significant Industrial Users to include a description of current and projected waste reduction (pollution prevention) activities. The codes listed are standard EPA codes found on Toxic Release Inventory and other environmental forms. Please check all applicable codes for your facility related to wastewater discharge. Current Projected Code Description X W13 Improved maintenance scheduling recordkeeping, or procedures NA W14 Changed production schedule to minimize equipment and feedstock changeovers NA W19 Other changes in operating practices (explain briefly in comments) X W21 Instituted procedures to ensure that materials do not stay in inventory beyond shelf-life NA W22 Began to test outdated material-continue to use if still effective NA W23 Eliminated shelf-life requirements for stable materials X W24 Instituted better labeling procedures NA W25 Instituted clearinghouse to exchange materials that would otherwise be discarded NA W29 Other changes in Inventory control (explain briefly in comments) X W31 Improved storage or stacking procedures X W32 Improved procedures for loading, unloading and transfer operations NA W33 Installed overflow alarms or automatic shutoff valves X W34 Installed secondary containment NA W35 Installed vapor recovery systems X W36 Implemented inspection or monitoring program of potential spill or leak sources NA W39 Other spill and leak prevention(explain briefly in comments) NA W41 Increased purity of raw materials NA W42 Substituted raw materials NA W49 Other raw material modifications (explain briefly in comments) NA W51 Instituted recirculation within a process Title: IU Wastewater Survey&Permit Application File name: I:\File\city of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 18 of 18 Industrial User Wastewater Survey & Permit Application Current Projected Code Description NA W52 Modified equipment, layout, or piping NA W53 Use of a different process catalyst NA W54 Instituted better controls on operating bulk containers to minimize discarding of empty containers N A W55 Changed from small volume containers to bulk containers to minimize discarding of empty containers NA W58 Other process modifications (explain briefly in comments) NA W59 Modified stripping/cleaning equipment NA W60 Changed to mechanical stripping/cleaning devices (from solvents or other materials) NA W61 Changed to aqueous cleaners (from solvents or other materials) NA W62 Reduced the number of solvents used to make waste more amenable to recycling NA W63 Modified containment procedures for cleaning units NA W64 Improved draining procedures NA W65 Redesigned parts racks to reduce dragout NA W66 Modified or installed rinse systems NA W67 Improved rinse equipment design NA W68 Improved rinse equipment operation NA W71 Other cleaning and degreasing operation(explain briefly in comments) NA W72 Modified spray systems or equipment NA W73 Substituted coating materials used NA W74 Improved application techniques NA W75 Changed from spray to other system NA W78 Other surface preparation and finishing(explain briefly in comments) NA W81 Changed product specifications NA W82 Modified design or composition of product NA W83 Modified packaging NA W89 Other product modifications (explain briefly in comments) NA W99 Other(specify in comments) Comments (Please list corresponding code) Title: IU Wastewater Survey&Permit Application File name: I:\File\city of Burlington Waste Water\Permit Renewal\Industrial Wastewater Survey IUP Permit Application Labcorp 06072021.docx Revision date: 12/30/97 Page 19 of 198 Labcorp — York Court Sample Points ff '' � •' i •• ', ' SAMPLE ' .I .. P .�_ „ POINT#1 y'Ct I , : '''' '',1- :I ' e f i� �4 33 At-,..4-**airt , 1, :- 4 ttF.# '.,. ,,„oration ' jr - h "' ' athoF. o Jy a ,.' ,:{ t, r i j ti rr ''' t r ; f� ' s 4 [.r F \ ''-' '' `' f » �. tin a 1(14 , t t _ --- i..: __t.t ,... i t ) . ' • .4., , •' . .4.,, ,::. , :;:.':',:-1. :, , .. ,,: "Nts.,... 4 f,f V. r'� .1 .J r w io „ r .u.._..ti g * f rsilgar» � M+�' ..Y y.. W4Front St rout - "� ' • . , WFront_ . ._ - Labcorp#66 r r Data Tracking Sheet Industry: Labcorp Quarter: 3&4 Permit#: 0066 Year: 2020 Pipe# pH Temp Flow BOD BOD TSS TSS Cu Cu Cr Cr Ni Ni Zn Zn Hg HG sampled S.U. deg C mgd mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs by IND or Limit»»> 001 5-11 50 300 150 0.10 0.10 0.015 0.25 0.0011 POTW Date 7/23/2020 5.9 27 0.022267 315 58.50 412 76.51 0.0472 0.01 0.106 0.02 0.0758 0.014 0.097 0.02 0.0012 0.0002 POTW <0.005 <0.005 10/13/2020 7.67 21.6 0.04 262 87.40 37.2 12.41 0.038 0.01 0.0025 0.00 0.0025 0.001 0.049 0.02 0.00095 0.0003 IND Maximum 7.67 27 0.04 315 87.4032 412 76.51 0.0472 0.01268 0,106 0.01968 0.0758 0.01408 0.097 0,0180133 0.0012 0.00031692 Average 6.785 24.3 0.031133 288.5 72.95 224.6 44.46 0.0426 0.01072 0.05425 0.0103 0.03915 0.00746 0.073 0.017 0.00108 0.000269882 %violation ;�� amity forL GTON .Ater Reseurces Page 1 Labcorp#66 Data Tracking Sheet Industry: Labcorp Quarter: 1 &2 Permit#: 0066 Year: 2021 Pipe# pH Temp Flow BOD BOD TSS TSS Cu Cu Cr Cr NI NI Zn Zn Hg HG sampled S.U. deg C mgd mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs by IND or Limit»»> 001 5-11 50 300 150 0.10 0.10 0.015 0.25 0.0011 POTW Date - 3/18/2021 6.4 14.6 0.025194 466 97.91 141 29.63 0.029 0.01 0.0071 0.00 0.0033 0.001 0.111 0.02 0.0033 0.0007 POTW <0.005 <0.005 4/8/2021 5.69 18.8 0.025516 109 23.20 87.3 18.58 0.03 0.01 0.0025 0.00 0.0025 0.001 0.19 0.04 0.00085 0.0002 IND Maximum 6.4 18.8 0.025516 466 97.9132 141 29.63 0.03 0.00638 0.0071 0.00149 0.0033 0.00069 0.19 0.0404329 0.0033 0.000693377 Average 6.045 16.7 0.025355 287.5 60.5545 114.15 24.102 0.0295 0.00624 0.0048 0.0010 0.0029 0.00061 0.1505 0.032 0.00208 0.00043713 %violation BCity tsf URLINGTON [h7ater Resources Y Page 1 s Data Tracking Sheet Industry: Labcorp(Pipe 2) Quarter: 3&4 Permit#: 0066 Year: 2020 pH Temp Flow BOD BOD TSS TSS Cu Cu Cr Cr Ni Ni Zn Zn Hg HG sampled S.U. deg C mgd mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs by IND or Limit»»> 6-11 50 300 150 0.10 0.10 0.015 0.25 0.0004 Date 7/23/2020 6 29 0.026333 2520 553.44 160 35.14 0.139 0.03 0.0557 0.01 0.0343 0.008 0.184 0.040 0.0005 0.0001 POTW <0.005 <0.005 <0.0002 10/13/2020 7.4 23.7 0.0412 3730 1281.66 18,9 6.49 0.059 0.05 0.0025 0.00 0.0025 0.001 0.047 0.016 0.0001 0.0000 IND Maximum 7.4 29 0.0412 3730 1281.66 160 35.1392 0.139 0.04776 0.0557 0,01223 0.0343 0.00753 0.184 0.0404101 0.0005 0.00011 Average 6.7 26.35 0.033767 3125 917.55 89.45 20.8167 0.099 0.03914 0.0291 0.00655 0.0184 0.0042 0.1155 0.0282798 0.0003 0.00007 violation ".ity of BURLINGTON ,.��#77ai r Res4+urccs Data Tracking Sheet Industry: Labcorp(Pipe 2) Quarter: 1 &2 Permit#: 0066 Year: 2021 pH Temp Flow BOD BOD TSS TSS Cu Cu Cr Cr Ni Ni Zn Zn Hg HG sampled S.U. deg C mgd mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs mg/L lbs by IND or Limit»»> 6-11 50 300 150 0.10 0.10 0,015 0.25 0.0004 Date <0.0002 3/18/2021 6.8 15.3 0.008968 2240 167.53 115 8.60 0.0674 0.01 0.007 0.00 0.0072 0.001 0.0865 0.006 0.0001 0.0000 POTW <0.005 <0.005 <0.0002 4/8/2021 6.8 21.3 0.014323 3580 427.63 32.4 3.87 0.054 0.01 0.0025 0.00 0.0025 0.000 0.065 0.008 0.0001 0.0000 IND Maximum 6.81 21.3 0,014323 3580 427.632 115 8.60096 0.0674 0,00645 0.007 0,00052 0.0072 0.00054 0.0865 0.0077643 0.0001 0.00001 Average 6.805 18.3 0.011645 2910 297.582 73.7 6.23558 0.0607 0.00575 0.00475 0.00041 0,00485 0.00042 0.07575 0.0071168 0.0001 0.00001 %violation Chivy tsar U LNGTO _____„Rid itie'r i Pace Analytical Services,LLC aceAnalytical 205 East Meadow Road-Suite A Eden,NC 27288 www.pacalabs.com (336)623-8921 April 23, 2021 Adrian Ridley Labcorp RE: Project: Semi-annual outfall 001 Pace Project No.: 92532215 Dear Adrian Ridley: Enclosed are the analytical results for sample(s)received by the laboratory on April 09,2021. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual,where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services-Asheville •Pace Analytical Services-Eden If you have any questions concerning this report, please feel free to contact me. Sincerely, Terri Page for Jessica L Mabe jessica.mabe@pacelabs.com (336)623-8921 Project Coordinator Enclosures cc: Ms.King,Lab Corp Mr.DJ Rice,Lab Corp /_ REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, without the written consent of Pace Analytical Services,LLC. Page 1 of 11 Pace Analytical Services,LLC aceAnalytical® 205 East Meadow Road-Suite Eden,NC 27288 www.pacalabs.com (336)623-8921' CERTIFICATIONS Project: Semi-annual outfall 001 Pace Project No.: 92532215 Pace Analytical Services Asheville 2225 Riverside Drive,Asheville,NC 28804 North Carolina Wastewater Certification#:40 Florida/NELAP Certification#:E87648 South Carolina Certification#:99030001 North Carolina Drinking Water Certification#:37712 VirginiaNELAP Certification#:460222 Pace Analytical Services Eden 205 East Meadow Road Suite A,Eden,NC 27288 North Carolina Wastewater Certification#:633 North Carolina Drinking Water Certification#:37738 VirginiaNELAP Certification#:460025 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, without the written consent of Pace Analytical Services,LLC. Page 2 of 11 Pace Analytical Services,LLC /+Q/��} /n ® 205 East Meadow Road-Suite A aceAna'ytical Eden,NC 27288 www.paeslabs.com (336)623-8921 SAMPLE ANALYTE COUNT Project: Semi-annual outfall 001 Pace Project No.: 92532215 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92532215001 Eff Comp 002 SM 2540D-2011 MLS1 1 PASI-E SM 5210B-2011 MWF 1 PASI-E EPA200.7 Rev 4.4 1994 SH1 4 PASI-A EPA 7470A SOO 1 PASI-A 92532215002 Eff Grab JLM2 6 PASI-E PASI-A=Pace Analytical Services-Asheville PASI-E=Pace Analytical Services-Eden REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, without the written consent of Pace Analytical Services,LLC. Page 3 of 11 aceA Pace Analytical Services,LLC rialytical 205 East Meadow Road-Suite A Eden,NC 27288 wunv.pawl�bs.cam '(336)623-8921 ANALYTICAL RESULTS Project: Semi-annual outfall 001 Pace Project No.: 92532215 Sample: Eff Comp 002 Lab ID: 92532215001 Collected: 04/08/21 15:30 Received: 04/09/21 08:00 Matrix:Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 2540D Total Suspended Solids Analytical Method:SM 2540D-2011 Pace Analytical Services-Eden Total Suspended Solids 32.4 mg/L 5.7 1 04/12/21 11:14 5210E BOD,5 day EDN Analytical Method:SM 5210B-2011 Preparation Method:SM 5210B-2011 Pace Analytical Services-Eden BOD,5 day 3580 mg/L 2.0 1 04/09/21 10:51 04/14/21 13:37 R6 200.7 MET ICP Analytical Method:EPA 200.7 Rev 4.4 1994 Preparation Method:EPA 200.7 Rev 4.4 1994 Pace Analytical Services-Asheville Chromium ND mg/L 0.0050 1 04/17/21 02:22 04/21/21 14:14 7440-47-3 Copper 0.054 mg/L 0.0050 1 04/17/21 02:22 04/21/21 14:14 7440-50-8 Nickel ND mg/L 0.0050 1 04/17/21 02:22 04/21/21 14:14 7440-02-0 Zinc 0.065 mg/L 0.010 1 04/17/21 02:22 04/21/21 14:14 7440-66-6 7470 Mercury Analytical Method:EPA 7470A Preparation Method:EPA 7470A Pace Analytical Services-Asheville Mercury ND mg/L 0.00020 1 04/14/21 15:22 04/14/21 18:48 7439-97-6 Sample: Eff Grab Lab ID: 92532215002 Collected: 04/08/21 15:35 Received: 04/09/21 08:00 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual Field Data Eden Analytical Method: Pace Analytical Services-Eden Performed by Pace mg/L 1 04/09/21 08:45 Analytical Collected By Charles mg/L 1 04/09/21 08:45 Hornback Collected Date 04/08/21 mg/L 1 04/09/21 08:45 Collected Time 15:35 mg/L 1 04/09/21 08:45 pH 6.81 mg/L 1 04/09/21 08:45 Temperature 21.3 deg C 1 04/09/21 08:45 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, Date:04/23/2021 09:32 AM without the written consent of Pace Analytical Services,LLC. Page 4 of 11