Loading...
HomeMy WebLinkAboutNCG500622_Compliance Evaluation Inspection_20211012ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH NORTH CAROLINA Director Environmental Quality October 12, 2021 Wayne Whitney, Operations Manager Purina Animal Nutrition, LLC 173 McNess Road Statesville, North Carolina 28677 Subject: Compliance Evaluation Inspection Purina Animal Nutrition, LLC NPDES Permit No. NCG500622 Iredell County Dear Mr. Whitney: Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject facility on October 5, 2021, by Mr. Wes Bell of this Office. Please inform the facility staff that oversee the environmental affairs of our findings by forwarding a copy of the enclosed report. Your consultant had previously submitted the Biocide/Chemical Treatment Worksheet-Form 101 for boiler treatment chemicals (Nalco 1720, NexGuard 22352 and Tri-ACT 1820) currently being used. The Division's Aquatic Toxicology Branch did not approve the discharge of these chemicals at the submitted dosage rates via correspondence dated June 18, 2020. Mr. Bell was informed by on -site staff that the detention basin does not discharge and staff should continue to ensure the basin does not discharge as long as the wastewater (boiler blowdown) contains the chemical composition of the unapproved dosage rates. If you or your consultant would like to discuss options, please contact Ms. Cindy Moore, Supervisor/Aquatic Toxicology Branch, by telephone at (919) 743-8442, or email at cindy.a.moore@ncdenr.gov. Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192, or via email at wes.bell@ncdenr.gov. Enclosure: Inspection Report NORTH Dep®rlmont of Environmental Onolit Sincerely, - DocuSigned by: '-A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 IL 21 1 1 1 1 NPDES yr/mo/day Inspection I 3 I NCG500622 111 121 21/10/05 117 Type 1810I I I 1 1 1 Inspector Fac Type 191 S I 2011 1 1 1 1 1 11 1 1 1 I I I 1 1 1 1 1 1 I I I I I 1 11 1 1 1 I 1 P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67I1.0 I 70I3 I 71IN I 72 I N I 73I 1 74 751 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES oermit Number) Purina Animal Nutrition, LLC 173 McNess Rd Statesville NC 28677 Entry Time/Date 12:25PM 21/10/05 Permit Effective Date 21/01/04 Exit Time/Date 01:15PM 21/10/05 Permit Expiration Date 25/11/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Bill Pendergrast/Maintenance Manager/704-924-5100 / Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Wayne Whitney,173 McNess Rd Statesville NC 286772742//704-924-5125/7048720298 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Wes Bell of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 10/12/2021 LIA), Geti A61696D9OCC3437... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger DWR/Division of Water Quality/704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: 10/12/2021 "-A14CC681AF27425... Page# 1 NPDES yr/mo/day 31 NCG500622 111 121 21/10/05 I17 Inspection Type 18 [j 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# 2 Permit: NCG500622 Inspection Date: 10/05/2021 Owner - Facility: Purina Animal Nutrition, LLC Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ application? Is the facility as described in the permit? • ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ • ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: The facility discharges boiler blowdown to a detention basin prior to discharge. Chemical additives (Nalco 1720, NexGuard 22352 and Tri-Act 1820) are added to the boiler system. The last compliance evaluation inspection at this facility was performed by DWR staff on 12/21/17. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • ❑ ❑ ❑ Is all required information readily available, complete and current? • ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ❑ ❑ • ❑ Is the chain -of -custody complete? • ❑ ❑ ❑ Dates, times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis • Name of person performing analyses • Transported COCs ■ Are DMRs complete: do they include all permit parameters? ❑ ❑ • ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ • ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ • ❑ operator on each shift? Is the ORC visitation log available and current? ❑ ❑ • ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ • ❑ Is the backup operator certified at one grade less or greater than the facility ❑ ❑ • ❑ classification? Is a copy of the current NPDES permit available on site? • ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ • ❑ Comment: The records reviewed during the inspection were organized and well maintained. Page# 3 Permit: NCG500622 Inspection Date: 10/05/2021 Owner - Facility: Purina Animal Nutrition, LLC Inspection Type: Compliance Evaluation Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? • ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? • ❑ ❑ ❑ # Is the facility using a contract lab? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ■ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ • ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ • ❑ Comment: Statesville Analytical Holdings, LLC has been contracted to perform analyses. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ • ❑ Is sample collected below all treatment units? ❑ ❑ • ❑ Is proper volume collected? ❑ ❑ ■ ❑ Is the tubing clean? ❑ ❑ • ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ • ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ❑ ❑ • ❑ representative)? Comment: The facility has not discharged; however, samples have been collected from the detention basin for analyses. Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, ❑ ❑ ■ ❑ and sampling location)? Comment: The non -contact cooling water would be discharged into a stormwater ditch; therefore, no instream monitoring is required (per Permit). Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ • ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable DEMO Solids, pH, DO, Sludge Judge, and other that are applicable? Page# 4 Permit: NCG500622 Inspection Date: 10/05/2021 Owner - Facility: Purina Animal Nutrition, LLC Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Comment: Boiler blowdown is discharged into a tank and pumped into an earthen detention basin. The detention basin had been cleaned out approximately one month ago. According to on -site staff, the detention basin does not discharge. The facility continues to use Nalco 1720, NexGuard 22352 and Tri-ACT 1820. These chemical additives were not approved to be discharged at their listed dosage rates per Aquatic Toxicity Branches' evaluation/memo dated 6/18/2020. The facility staff must ensure that no discharges occur from the detention as long as these chemical additives are present in the wastewater/detention basin. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ • ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ • ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ • ❑ Comment: No discharges were observed during the inspection. The water level in the detention basin was several feet below the discharge outlet. Page# 5