HomeMy WebLinkAboutWQ0039705_Application (FTSE)_20211029Permit Number WQ0039705
Program Category
Non -discharge
Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions
Primary Reviewer
dean. hunkele
Coastal SWRule
Permitted Flow
0
Facility
Central Files: APS _ SWP _
10/20/2021
Permit Tracking Slip
Status
Project Type
In review
Major modification
Version
Permit Classification
B
Individual
Permit Contact Affiliation
Facility Name Major/Minor Region
2 Chairs Restaurant Public Force Main Minor Wilmington
Location Address County
Brunswick
Facility Contact Affiliation
Owner
Owner Name Owner Type
Brunswick County Government - County
Owner Affiliation
John Nichols
PE
PO Box 249
Dates/Events Bolivia NC 2842202•
Scheduled
Orig Issue App Received Draft Initiated Issuance
1/25/2018 10/18/2021
Regulated Activities
®
;] A
mcgill
October 18, 2021
Mr. Dean Hunkele
Division of Water Quality
NCDEQ — Wilmington Regional Office
127 Cardinal Drive Extension
Wilmington, North Carolina 28405
RE: 2 Chairs Restaurant Public Force Main
Brunswick County
NCDEQ Permit #: WQ0039705
Fast Track Sewer System Extension Modification
Dear Mr. Hunkele:
Shaping Communities Together
RECEIVED/NCDENFUDWR
OCT 18 2021
water Quality Regiorml
pperetiwn seakwn
Wii Regional Ofl e
On behalf of Brunswick County, we respectfully request your review of the following documents
for a modification to the subject project's existing wastewater collection system permit:
• 1 Original and 1 Copy of the Fast Track Sewer System Extension Application
• 1 $480.00 Application Fee Check
• 1 Copy of a Memo Regarding Design Calculations
• 1 Copy of a Site Location Map
• 1 Copy of a Street Level Map
The modification is being requested due to a change in the material and diameter for a portion
of the force main covered under permit no. WQ0039705. 130 linear feet of force main, originally
permitted to be 3" DR 9 HDPE, was installed as 2" SDR 21 PVC due to a construction change
to the method of pipe installation.
Thank you for your attention to this matter. Please do not hesitate to reach out to me should you
need any additional information.
Sincerely,
MCGILL ASSOCIATES, P.A.
ZACHA Y ROMAN, P.E.
Project Engineer
Enclosure: None
Cc: None
P:\2020\20.07101-Murdock-2Chairz\Closeout\Sewer\Public Portion\Submittal to DWR\Cover Letter.docx
MCGILL ASSOCIATES 712 VILLAGE ROAD SW, SUITE 103, SHALLOTTE INC 28470 / 910.755.5872 / MCGILLASSOCIATES.COM
Application Number:
State of North Carolina
Department of Environmental Quality
Division of Water Resources
FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 06-21 & SUPPORTING DOCUMENTATION
(to be completed by DWR)
All items must be completed or the application will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Brunswick County (company, municipality, BOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal B® State/County ❑ Municipal ❑ Other
3. Signature authority's name: Willam L. Pinnix per 15A NCAC 02T .0106(bl
Title: Director of Engineering
4. Applicant's mailing address: PO Box 249 3LnbT
City: Bolivia State: NC Zip: 28422-
5. Applicant's contact information:
asoo
Phone number: (910) 253-2"+ Email Address: william.pinnix(abmnswickcountync.eov
II. PROJECT INFORMATION:
1. Project name: 2 Chairz
2. Application/Project status: ❑ Proposed (New Permit) Existing Permit/Project
If a modification, provide the existing permit number: WQ0039705 and issued date: 1-25-18,
For modifications, also attach a detailed narrative description as described in Item G of the checklist.
If new construction, but part of a master plan, provide the existing permit number: WQ00_
3. County where project is located: Brunswick
4, Approximate Coordinates (Decimal Degrees): Latitude: 33.9185' Longitude:-78.2688'
5. Parcel ID (if applicable): _ (or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: Zachary Roman License Number: 049509
Firm: McGill Associates
Mailing address: 712 Village Road SW, Suite 103
City: Shallote State: NC Zip: 28470-_
Phone number: (9) 755-5872 Email Address: Zachary.roman(a mcgillassociates.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
i,esT gay Eck 73'.g3
1. Facility Name: My Permit Permit Number: kJ a �%i% t.�—/ .
Owner Name: Brunswick County
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
1. Permit Number(s): WQ0029934
2. Downstream (Receiving) Sewer Information: 16 inch ® Gravity ❑ Force Main
3. System Wide Collection System Permit Number(s) (if applicable): WQCS00284
Owner Name(s): Brunswick County
FORM: FTA 06-21 Pagel of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑ No ® N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes ❑ No ® N/A
3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and
supplementary documentation as required by 15A NCAC 02T.01 15(c) been attached?
[-]Yes ❑ No PQ N/A
4. Origin of wastewater: (check all that apply):
❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential (Leased) ® Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic % Commercial _ % Industrial (See 15A NCAC 02T .0103(20))
If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ®No
➢ If yes, provide a copy of flow reduction approval letter with this application
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(f))
Daily Design Flow','
No. of Units
Flow
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
0 GPD
a See 15A NCAC 02T .0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 0 GPD (per l5A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, please indicate why:
❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line.
Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow.
❑ Flow has already been allocated in Permit Number: Issuance Date:
❑ Rehabilitation or replacement of existing sewers with no new flow expected
® Other (Explain): Flow allocated on private PS Permit for 2 Chairz LLC (Private Duplex PS)
FORM: FTA 06-21 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC Moran Stations/Force Mains):
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION rNCLUDED IN THIS PROJECT
1. Pump station number or name: l
2. Approximate Coordinates (Decimal Degrees): Latitude: 33.9177' Longitude:-78.2685'
3. Total number of pumps at the pump station:
3. Design flow of the pump station: 0.0634 millions gallons per day (firm capacity)
➢ This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s) per pump(s): 44 gallons per minute (GPM) at 30 feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
2
503
SDR 21 PVC
If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per
MDCPSFM Section 2.01C.Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify)
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or ❑ Standby pump
➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B).*
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C):
❑ Portable power source with manual activation, quick -connection receptacle and telemetry -
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
as part of this permit application in the case of a multiple station power outage.
FORM: FTA 06-21 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)):
1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f) & (g)? ® Yes []No
15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems:
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
24 inches
'Water mains (vertical - water over sewer preferred, including in benched trenches)
18 inches
'Water mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water, and associated wetlands.
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands associated with these waters (see item IX.2)
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches, as well as wetlands associated with these waters or classified as WL.
10 feet
Any building foundation (horizontal)
5 feet
Any basement (horizontal)
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade (vertical)
36 inches
➢ If noncompliance with 02T.0305(f) or (a). see Section X.1 of this application
*15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes"
above if these alternatives are used and provide narrative information to explain.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webpage
2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A
➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document,
signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule.
3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A
➢ Please provide supplementary information identifying the areas of non-conformance.
➢ See the Division's draft separation requirements for situations where separation cannot be met.
➢ No variance is required if the alternative design criteria specified is utilized in design and construction.
4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name:_ ® No
If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No
➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202
5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No
or 401 Water Quality Certifications?
➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required.
6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes [-]No
Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared,
have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion
and sedimentation control plans, stormwater management plans, etc.).
7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No
Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters,
siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit.
FORM: FTA 06-21 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest versionl and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
® Yes ❑ No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued
concurrently with the approval of the permit, and oroiects requiring a variance approval may be subject to loneer
review times. For oroiects requiring two or more variances or where the variance is determined by the Division to be a
significant portion of the project, the full technical review is required.
2. Professional Engineer's Certification:
I, Zachary Roman , attest that this application for 2 Chairz
(Professional Engineer's name from Application Item 111.1.) (Project Name from Application Item 1I.1)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application
information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject
the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701)
North Carolina Professional Engineer's seal, signature, and date:
\� tC ARO
Digitally signed by
= o SEAL a
049509 e
Zachary Roman
Date:2021.10.14
%9C' °-4cINEC.
�''ygRy P
13:21:11-04'00'
•?:``��
I I I I 1 "
3. Apppl�ic�ant's Certiper 15A NC C 02T .0106(b):
W/t1 . I. Alf i> n. X / � . �7
I, AZWM74ft!r ' UA' , attest that this application for e#"9-y7_
(Signature Authority Name from AlIlication Item (Project Name from Application Item 1I.1)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in y application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as we civil penalties up to $25,000 per violation.
Signature: ✓" w O /� ° Date: lVzf
FORM: FTA 06-21 Page 5 of 5
Shaping Communities Together
mC9III'
TO: Mr. Dean Hunkele, North Carolina Department of Environmental Quality
FROM: Zachary Roman, Project Engineer
DATE: October 14, 2021
RE: Permit No. WQ0039705 As -Built Calculations
Mr. Hunkele,
As indicated on the subject project's as -built drawing, sealed on July 14, 2021, the material and
diameter of a portion of the public force main for the project were changed from the permitted
values. Specifically, 130 linear feet of DR 9 HDPE force main was changed to 130 linear feet of
SDR 21 PVC force main. The as -built conditions for the public portion of the project's force main
are as follows: 503 linear feet of SDR 21 PVC. This change occurred due to a field adjustment
of the installation method for the proposed 130 liner feet of DR 9 HDPE force main (direction
drill to open trench).
The subject project's design calculations, originally sealed on August 31, 2017, and revised on
October 11, 2017, contained a system head calculation for the entire run of force main
(including both the public and private portions). The pipe length value used in the calculation
was 800 linear feet while the actual length shown on the design plans and installed was 653
linear feet. The value used in the calculation was about 22% greater than the actual amount of
force main installed. Therefore, the total dynamic head calculated for the system includes a
factor of safety due to the pipe length value. The change in force main material and diameter
made in the subject project's construction phase would be captured by the originally included
factor of safety; the original design calculations remain valid.
Please review the system head calculation included with this memorandum. Do not hesitate to
reach out to me if there are any questions.
NICGILL ASSOCIATES 712 VILLAGE RD S'vV, SUITE 103. SHALLOTTE. NC 28470 910.755. 5872 i NICGILLASSOCIATES-CONI
2 CHAIRZ RESTAURANT
Street View of Site
W a k> 1, i k�;ti 7- 9�:,
2017 X jL
A:.
Google Earth
a
0 2017 Google.�R
ft
�14
1V