Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0032268_Regional Office Historical File Pre 2018
1, s Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality October 2, 2007 Mr. Ben Stevens, Director of Land Development Centex Homes 4235 South Stream Boulevard Charlotte, NC 28217 Subject: Permit No. WQ0032268 Corrected Copy The Bridges Wastewater Collection System Extension C-MU TRACKING #600-07-584 Mecklenburg County, North Carolina Dear Mr. Stevens, In accordance with your application received on September 12, 2007, we are forwarding herewith Permit No. WQ0032268, dated October 2, 2007, to Centex Homes for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, a's applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet www.ncrnwaterquality.org Customer Service: 1-877-623-6748 An Equal opportunity/Affirmative Action Employer— 50% Recycledl10% Post Consumer Paper One NCarolina tura!!y Mr. Stevens Page 2 October 2, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 1,041 linear feet of 8-inch gravity sewer and the discharge of 6,080 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system, pursuant to the application received September 12, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes §143-215.6A to §143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utilities WWTP (McAlpine Creek NPDES No. NC0024970) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins oy2S/v? cc: Mecklenburg County Land Use and Environmental Services Agency (LUESA) Steve Miller, CMU Philip Edward, Mecklenburg County Mooresville Regional Office, Collection System Permit File Robert M. Baysden, ColeJenest & Stone, PA Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. A map of the sewer system shall be developed and shall be actively maintained. An operation and maintenance plan shall be developed and implemented. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. High -priority sewer lines shall be inspected at least once per every six-month period of time. a. b. c. d. e. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part l of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 2nd day of October, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION / /1 /2"-- «/ for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032268 Corrected Copy Fast Track Engineering Certification Permit No. WQ0032268 Corrected Copy October 2, 2007 OwnerNVQCS Ben Stevens, Dir of Land Dev. Centex Homes 109 Laurens Rd. Greenville, SC 29603 PE Robert Baysden, ColeJenest & Stone, PA ColeJenest & Stone, PA 200 South Tryon Street, Suite 1400 Charlotte, NC 28202 WQCSNVWTP Steven Miller Charlotte Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ['full time) the construction of The Bridges, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality October 2, 2007 Mr. Ben Stevens, Director of Land Development Centex Homes 4235 South Stream Boulevard Charlotte, NC 28217 Subject: Permit No. W00032268 The Bridges Wastewater Collection System Extension C-MU TRACKING #600-07-584 Mecklenburg County, North Carolina Dear Mr. Stevens, In accordance with your application .received on September 12, 2007, we are forwarding herewith Permit No. WQ0032268, dated October 2, 2007, to Centex Homes for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains. adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet www.ncmwaterquality,org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer —50% Recycled/10% Post Consumer Paper No `Carolina Naturally Mr. Stevens Page 2 October 2, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 1,041 linear feet of 8-inch gravity sewer and the discharge of 29,160 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system, pursuant to the application received September 12, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes §143-215.6A to §143-215.6C, for violation of or failure to act in accordance with the terms and conditions of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utilities WWTP (McAlpine Creek NPDES No. NC0024970) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you havethe right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, --721- 6 for Coleen H. Sullins cc: Mecklenburg County Land Use and Environmental Services Agency (LUESA) Steve Miller, CMU Philip Edward, Mecklenburg County Mooresville Regional Office, Collection System Permit File Robert M. Baysden, ColeJenest & Stone, PA Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365. days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per.year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. in the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice .mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 2nd day of October, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032268 3 Fast Track Engineering Permit No. WQ0032268 October 2, 2007 OwnerNVQCS Ben Stevens, Dir of Land Dev, Centex Homes 109 Laurens Rd. Greenville, SC 29603 Certification PE Robert Baysden, ColeJenest & Stone, PA ColeJenest & Stone, PA 200 South Tryon Street, Suite 1400 Charlotte, NC 28202 WQCSAANVTP Steven Miller Charlotte Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the,Division. ENGINEER'S CERTIFICATION ❑. Partial .. ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of The Bridges, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina. Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: • � (to be completed by DWQ) l� 'la. Centex Homes Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Ben Stevens, Director of Land Development Q '1d. 4235 South Stream Boulevard Mailing Address 1f. North Carolina 0 State Zip Code 1h. (704) 523-8111 i1 i. (704) 522-0975 1j. bstevens@centexhomes.com QTelephone Facsimile E-mail ,: (} !2. Project (Facility) Information: a 2a. The Bridges Brief Project Name (permit will refer to this name) County Where Project is Located 3 Contact Person: 3a. Jason W. Galloway, El (Civil Engineer) ' Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. g04) 376-1555 3c. jgalloway©colejeneststone.com i Phone Number E-mail i Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) i1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality ❑ State/County 0 Private Partnership ®-Corporation ❑ Other (specify): _ 1 Ie. Charlotte I City 1 g. 28217 B. PERMIT INFORMATION 1. Project is ® New ❑ Modification (of an existing permit) 2b. Mecklenburg If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ❑ Public (skip to Item B(3)) 2a. If private, applicant will be: Z Private (go to Item 2(a)) ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to item B(3)) ® Selling units (lots, townhomes, etc. - go to Item B(2b)) 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction III) ® Homeowner Assoc./Developer (Instruction IV) 3. Charlotte -Mecklenburg Utilities (CMU) Owner of Wastewater Treatment Facility (WWVfF) Treating Wastewater From This Project ',4a. McAlpine Creek Wastewater Treatment Plant 4b. NC0024970 Name of WWTF WWTF Permit No. 5a. Charlotte -Mecklenburg Utilities 5b. Pr. 8" / Ex.36" IN Gravity 5c. (Ex.36" )_C-MU #600-07-584 / (Pr.8") CMU#100-07-554 I Owner of Downstream Sewer :Receiving Sewer Size !E❑ Force Main I Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply): Residential Subdivision D Apartments/Condominiums ❑ Mobile Home Park D School D Restaurant ❑ Office ❑ Car Wash ❑ Institution ❑ Hospital 0 Church 0 Nursing Home ❑ Other (specify): 100 %- Domestic/Commercial % Industrial % Other (specify): Volume of wastewater to be allocated for this particular project: 6 080 gallons per day *Do not include previously permitted allocations . If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev., 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). 32 units x (190 GPD/unit) = 6,080 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8" 264 8" 8„ 8" Cl 8" W 8 ENTER TOTAL LINE LENGTH IN MILES 0.197 V11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Z 127 150 159 Gravity or Force Main (use the pull down menu) Gravity Gravity Gravity Gravity 161 Gravity 180 Gravity O. Location ID Power Reliability Option (self chosen - as shown on Design Flow' Operational Point ! (1- dual line feed; 2- permanent generator wlATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generatorw/telemetry; 4 wet well storage) 0 LL 112. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force r Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? W ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a Q. variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION ❑ 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ® Yes 0 No ® Yes ❑ No Stormwater? ® Yes ❑ No Sedimentation and Erosion Control Plan? ❑ N/A O N/A ❑ NIA 14. Does this project involve aerial lines or siphons? Check if yes: ❑ 1.hese-lines will.be considered blots priority .and mustbe.checked.once_everv.six.months...__ _ _ _- 15. Does this project have gravity sewer lines designed at minimum slopes? Be aware that the Division will not accept installed lines more than 1 O% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. JI FTA 02/03 - Rev. 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 Z 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: w Qwaterbody; ►i A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope AND, C.) LL ® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Cl) Location ID on Map (self chosen - as shown on map for cross-reference) Name of Waterbody County River Basin Waterbody Stream Index Waterbody Classification —I C.) Q W - H ---CC t/) U • Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1. Ben Stevens, attest that this application for The Bridges Home Owner's Association, Inc has been reviewed by me and is accurate and complete to the best of my knowledge. ! understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143- 215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penal ' up to $25,000 per violation. ia. 'I $/b/07 Sign' Ithlfficial Signature Date . cn Z H 4 V Li H cC _ W V G . Prof -s- nal Engineer's Certification: 1 attest that this application for The Bridges Home Owner's Association, Inc has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that ! have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Robert M. Baysden, PE Professional Engineer Name r2b. ColeJenest & Stone, PA Engineering Firm 2c. 200 South Tryon Street, Suite 1400 Mailing Address 2d. Charlotte �2e. NC 2f. 28202 �City State Zip 2g. (704) 376-1555 12h. (704) 376-7851 2i. rbaysden@colejeneststone.com 1 Telephone I Facsimile I E-mail Seal, Signature & Date F-rA 0f/01 - Rev 1 04/05 1,0 and between. Carllt3aof a tlt North ctf the L£��ill 'ts thy, t1Vltc t rtttts Altat c>tltcr llt )t rest ai�yc.ltttt ialtfotl i1 c• fle Wall r sst ,e 04, at allact talail5 d o North Caro I ,f the 41C or t't has llc t�i VVt es 1tlatevs 1 l tctg e rc�ist c;tart?t)raltll�tl ci Ns t ll:atic�tl '1 he cart- the plop. Stale lairs 111 a ar0littat fear ,llarlYl operating, tflaitlttla�a Stale of of i e t unit w.. llt. the Develop t mots ;ubiee1 such operation, i) ��, for , etta lenient rontn 'tlt`tt• OMMISS10;- and tt paarttael ;hip r 11�1"tt \aat'ttlt:h tr uhtlrg, Coutt) Y t'< ltt devetuptlic tlt trt tt> vtt"trM � TM ltt`�. attt't�nt velop et waste ' t� ;ICr�rt r collection ollt1 ern with putttp", sewage tf sli s d tc+ r r rlilcYc'l c>ll tiywtovi et"tt� t� provide sanitary . t _S. 143- tshiptnsada rshtp thereiil3fte cis an t pt . provide hint t s,tnasa qai lands . °�"xts p tillt tiaelti) lave 4 to alsstsre- uYtlanet✓ desires �l and operatedact the public interest VstlitalS Of a 4uattl".'r"`* a)1 ttte, �itait�% � cll''C1 t tt�t;S M re °c=c)t1S (shii), ctstttrtctlat, l the f tt ae �� the tarc)lt. tllults^t11 • ct lattit) clatt) consideration i)1'1:..[� stet 1te,teh"i 1 � t ,.t ita v 1 , . l tit ut ita i ION, an xT1t'�1Zt, �} alicl t)1+= the Disposal � �" cf)� rn �.n�titS�1() � �hcatii" keretc . he , shall construct t tt, p s try al the. vitia dtp4 } V i' i t)11'1� y tsllecl lu� aapp � accordance cif tt The n "lit 4 ttl 1 ` c �tl�altiiatl� l�et� cilitle... e et)tttri Maas rt)ci la' cwtaetilt(t atltic)r s �;taclt ""�' �vitta tits p� anct ttlatttt�tttt att etatclaauc l,scel ct tt )1: :1. -1't shall t t�l)t transfer ett completeto t att� a1'ap ktlttttltl hasuht`i h,, ttt,ltet ltc 1,�ta1 }t. tilaSk 1. *titer ', _ sty t.)�s°lslu � t1t� tf� he i static l )iai 1. a Of the �� saallctl sl'altst. ottitrtit� tilt, c�tsaye)`, „,01 r cttlr st 1). �, shall not tt �ltt Of il'� tllai llaatittlr�ttatta�.t. ilt,t: attic al a t" . xs ss other iitiprl7`�erneltts pursuant nt to Chap �rtue Of the and. the , affairsandbu • pr0l rt ctrtlurtO1l el ttte ug, the pc)sal System; aatt t�ct' vt t1 constoction tteti�attec..rc:.., ��t, „f 11t 1ev, opt ent s. e� til1'aslt)tt�* y. I`opoZone o USGS Weddington (NC,SC) 'Tape Map Page I of I 0.09 0.18 0.27 0.36 0.45 mi UTM 17 514981E 3880381N (NAD27) USGS Weddington (NC,SC) Quadrangle Projection is UTM Zone 17 NAD83 Datum ,topozone.com/printasp?lat=35.06784 ona-80.8357&s=24&size=l&u=4&lay... 8/2 /2O07 2 NC DENR MRO D -Surface Water Prat fan SUBJECT WATER AND SANIT AR YSEWER FLOW ACcE:P AtsiCE THE RIDGES TAX PARCEL 4>23-481,V, —02, C„MU TRACKINCC # 00.07- 4 Permit Number WQ0032268 Central Files: APS SWP 10/02/07 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 6080 Facility Facility Name MajorlMinor Region The Bridges Minor Mooresville Location Address Owner County Mecklenburg Facility Contact Affiliation Owner Name Owner Type Centex Homes Non -Government DateslEvents Orig Issue 10/02/07 App Received Draft Initiated 09/12/07 Regulated Activities Subdivision Wastewater collection Outfall NULL Scheduled Issuance 'Owner Affiliation Ben Stevens 4235 S Stream Blvd Charlotte Public Notice Issue 10/02/07 NC 28217 Effective Expiration 10/02/07 Re : ues eel/Received Events Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin Page 1 of 2 Donovan, Jack From: Stevens., Benjamin Sent: Thursday, September 13, 2007 8:10 AM To: Donovan, Jack; Quinlivan, Jeff Subject: FW: The Bridges Sewer Extension Fees See below, Ben. Stevens Director of Land Development Centex Homes- Charlotte c: 704-400-1842 o: '704-529-2309 f: 704-522-0975 From: Stevens, Barbara H Sent. Wednesday, September 12, 2007 4:00 PM To: Stevens, Benjamin Subject: FW: The Bridges Sewer Extension Fees From: Rob Krebs [rnailto:rob.krebs@ncmail.net] Sent: Wednesday, September 12, 2007 12:49 PM To: Stevens, Barbara H Cc: Dee Browder Subject: The Bridges Sewer Extension Fees Dear Mr. Ben Stevens: As of September 1, 2007 the Application Fee for the Fast Track Gravity Sewer Permit has been increased from $40100 to $480,00. Please supply the appropriate fee as per required by. the North Carolina Session Law 2007-323. WATER QUALITY PERMIT FEES SECTION 30.3.(a) G.S. 1.43-21.5.3.D reads as rewritten: °"§ 143-215.3D. Fee schedule for water quality permits. Annual fees for discharge and nondischarge permits (e) Other fees under this Article. — (1) Sewer System Extension Permits. — The application lee for a t for the construction of a new sewer system or for the extension of an existing sewer system is four hundred eighty dollars ($480.00). Please send in the additional $80.00 to process the application. If the payment is not received by this office within seven days, we will return the entire application. Checks must be made payable to "North Carolina Dept. of Environment and Natural Resources (NCDENR)". In addition, item # 1 and #4 of the permit application require copies of the application and the operational 9/13/2007 Page 2 of 2 agreements. All future applications must include the requested copies or the applications will be returned as incomplete. Sorry for the inconvenience. Sincerely, Robert Krebs Mooresville Regional Office Surface Water Protection Section Supervisor Rob Krebs - Rob w Krebs@ncma ii. rn. North Carolina Dept. of Enviro Div. of Water Quality 610 E. Center Ave., Suite 301 Mooresville, NC 2.8115 Ce11 (704) 307-7460 Ph: (704) 235-2176 Fax: i704) 663-6040 e t & Natural Resources 9/1 3/2007 C DEAR MRCS 0- ace 'eater Prot an LAND DEVELOPMENT Transmittal Thursday Sept 13, 2007 From: ack Donovan Telephone: 704-522-4580 Fax: 704-522-0975 Plan Number: Sheets: The Brid Rob, To: Rob Krebs Norte Carolina Dept. of Environment & Natural Resources Div. of Water Quality 610 E. Center Ave., Suite 301 Mooresville, NC 28115 Telephone: 704-325-2176 Fax: 704-663-6040 Company: '' NCDNER As requested in your email, uncluded are two additional copies of the fast track application and Developer's Operational Agreement, the additional $80 review fee, and your original email. If you have any questions, please give me a call. Thank you. - Jack Donovan 704-307-3488 File 0 For your information. Review and Comment. For your use. fl Review and respond back. 0 For your use as requested. Q Attach revised drawings Col- enest & Stone Sh.,:iping die Environment 14,1r,,,ing the Land Planning ArchoTcture Date: September 11, 2007 Reference: 3584 — The Bridges Attention: Ms, Dee Browder SF' 2 I TRANSMITTAL NC DENR MRO DM -Surface Water Protection Company: North Carolina Department of Environment and Natural Resources Mooresville Regional Office Division of Land Resources 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 We Are Transmitting: Tel: (704) 663-1699 Herewith El Under Separate Cover Copies 2 1 1 2 Dated 09/06/07 09/04/07 08/29/07_ 05/23/07 09/06/07 Description Fast Track Application for Gravity Sewers, Pump Stations and Force Mains Arrnlication Fee (Check No: 2604 Flow Acceptance Developer's Operational Agreement Transmitted 0 Mail Overnight 0 Courier 1:1 Hand Delivery 0 Pick -Up Via: El For Approval El For Your Use As Requested E] For Review Remarks: Attached is the Fast Track Application for your approval. Also attached are the associated fees, topographic map, Flow Acceptance Letter and Developer's Operational Agreement as required. By: cc: Kindly call with any questions. , Galloway, El all Mr. Jack Donovan - CH Mr, Dudley D. Stone, PE — CJS Mr. Robert M. Baysden, PE - CJS Shaping the Environment,' ReaL.inkii4 the Possibleihes ?eke) South re„„her i'tetkreet7 Sket:e i„ Cheieceitic. ir30,1 ,C07,2eitie Date: September 20, 2007 Reference: 3584 — The Bridges Attention: Ms, Dee Browder Company: North Carolina Department of Environment and Natural Resources Mooresville Regional Office Division of Land Resources 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 We Are Transmitting: Transmitted Via: Copies 0 Mail Tel: TRANSMITTAL (704) 663-1699 Herewith 0 Under Separate Cover Dated Description 09/20/07 Fast Track Application for Gravity Sewers, Pump Stations and Force Mains — Page 5 Only overnight 0 Courier For Approval El For Your Use 0 Hand Delivery 0 Pick -Up 0 As Requested 0 For Review Remarks: Per a message from Rob Krebs, attached is Page 5 of the Fast Track Application with an original seal and signature for your approval. By: r" pakil/ NC DENR MR0 Kindly call with any questions. Mr, Rob Krebs - NCDENR Mr. Jack Donovan — CH urface Water Protection Mr. Dudley D. Stone, PE — CJS Mr, Robert M. Baysden, PE - CJS cc: kik id Le, s kia dee kiLititiei, k ratitaa).0.d. , iddn. 1 faib.nitt , dd. FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCEFORC1 MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" 10 collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z regional office (see instructions for addresses) pR indicate the following: 0 AStreamClaNsp,sification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; A ' A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map ' 1 (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference Waterbody County River Basin Index Classification Submit the 8.5 x 11 COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! , 1. Applicant's Certification: I. Ben Stevens, attest that this application for The Bridges Home Owner's Association, Inc has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143- ! 215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil pe .... , up to $25,000 per violation. la. Sig Official Signature " Pr e nal Engineers Certification: 0 1 atte at this application for The Bridges Home Owner's Association, Inc has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation Pm' to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Robert M. Baysden, PE Professional Engineer Name 2b. ColeJenest & Stone, PA Engineering Firm 2c, 200 South T on Street, ui 1400 Mailing Address 2d. Charlotte 2e. NC 2f. 28202 ,. ,.., City State Zip 2g. (704) 376-1555 2h. (704) 376-7851 2i. rbaysden@colejeneststone.com Telephone Facsimile E-mail Seal, Signature 8, Date FT A own' Rpv WADS 2 07 NC DENR ILRO DW FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02J03 (FAST TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ® A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, _ _ ® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. —7 Location ID on Map (self chosen - as shown on Name of l Waterbody Stream i map for cross-reference)_ i_ Waterbody County River Basin Index 1 a Submit the 8.5" x 11" COLOR topographic map as required in instruction VI regardless of whether a classification is provided! Waterbody Classification `1. Applicant's Certification: 1. Ben Stevens, attest that this application for The Bridges Home Owner's Association, inc has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retuned as incomplete. Note: In accordance with North Carolina General Statutes 143- 215 6A and 143 215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil pen- -s up to $25,000 per violation. 31 a. Sig Official Signature nal Engineer's Certification: ate 1 attes"hat this application for The Bridges Home Owner's Association, Inc has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. i further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of,a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Robert M. Baysden, PE Professional Engineer Name 2b. ColeJenest & Stone, PA ' Engineering Firm 2c. 200 South T on Street, Suite 1400 Mailing Address 2d. Charlotte 2e. NC 2f. 28202 City State Zip 2g. (704) 376-1555 2h. (704) 376-7851 2i. rbaysden@colejeneststone.com ' Telephone Facsimile ' E-mail ,0000rnopo" M cps e ' 25548 z e4942.9 l `�rs o � � d Seal, Signature & Date FTA n7103 - Rev 3 (141(15 FAST TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 C.-STREAM CLASSIFICATION 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02J03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ® A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, _ _ _ _ ® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map I 1 (self chosen - as shown on Name of 1 1 Waterbody Stream I Waterbody map for cross-reference) 1 Waterbody _ County _ River Basin j _ Index _ Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction Vi regardless of whether a classification is provided! Z 0 1— a c.) LL 1-- cc W U C l a. Applicant's Certification: 1. Ben Stevens, attest that this application for The Bridges Home Owner's Association, Inc has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: in accordance with North Carolina General Statutes 143- 215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil pen ; -s up to $25,000 per violation. �r lit , Official Signature 2. Pr•' aIna! Engineer's Certification: I aites hat this application for The Bridges Home Owner's Association, Inc has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: in accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Robert M. Baysden, PE Professional Engineer Name 2b. ColeJenest & Stone, PA ' Engineering Firm 2c. 200 South T on Street, Suite 1400 Mailing Address 2d. Charlotte City 2e. NC 2f. 28202 State Zip 2g. (704) 376-1555 2h. (704) 376-7851 2i. rbaysden@colejeneststone.com Telephone Facsimile E-mail a " �'`rgaaeaasaao�(! Li Seal, Signature & Date FTA f17/(11 - Rev 1 (14/(1S FATE OF NORTH CARC)I. INA. COt..tNTY O Mee' PEK: )PERA1'IONA ., AGR 1`MIIMNT N"%' taaat to tatrtsaratat to G S. I43-21.5.I (d 1 f and entered into this and between the North Carolina Environmental ental 1).4 anaagenrcnt 'sign, an agency of the State of North Carolina„ hereinafter known as the COMMISSION; and Hex Homes_ . : °_. ..._ _...w. a teat ration/general partnership ed to do bus, rtess ita the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH. The DEVELOPL R is the owner of the certain lands lying in Mecklenburg Coatnty, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as The Bridges Home Owners Association, Inc, (hereinafter the Development). The DEVELOPER desires, to constnrct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the, Development on said latncls. °h, .DEVELOPER has applied to the COMMISSION for the issuance of a 215.1 to construct, maintain, and operate the Disposal System, The DEVELOPER. has created or shall create unit ownership in said dwellings units, (flier i.natarovenrents and lands through tiling of a Declaration of Unit Ownership (hereinafter Deck :at o.n), pursuant to Chapter 47C or 47F of the North Carolina General Statutes, r G.S. 143- 5. The DEVELOPER has caused to he formed or will catuse to ht formed at the tinier of filing of the:. Deciaaration, The Bridges Home Owners Association, Inc. (hereinafter Associatio,n), as non-profit corfaorat.ion organized and existing under and by tlx: virtue o State of North Carolina, for the purpose, among others, of handling the property, affairs an the Development; of operating, rnaaintaaining, re -constructing and repairing the common elements of"the lands and improvements subject to unit ownership, including the, Disposal System; and of collecting dues and assessments to prov de funds for such operation, maintenance, re -construction and repair. f . The COMMISSION desires to assure that the Disposal System of the Dcvcloprrrcnt: is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect tht quality (tithe waters of the State and the public interest therein. NOW, 'THEREFORE, in consideration of the: promises and the bench's to hereto, the COMMISSION and i)EVILOPER. do hereby mutually agree as Itrl 1. The DEVELOPER shall construct the. Disposal System in accordance with the pernut and plans and shelf ica.tions hereafter issued and approved by the COMMISSION, and shall thereat' ter properly operate and maintain such systems and facilities in accordance with .applicable pe.nrrit provisions atnd law. The 1:,)EVEI.,.()PI R shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the petnait and approved plans, and the staff a.et° the Di isicara caf \Vaater Quality has inspected and approved of the facilities. In order to change the flatrae: the penun holder, the DEVELOPER 'must request that the permit he reissued to the Association. The request MUM include a cope of the ,Association Bylaws and Declaration,. 3, The I )EVl d..OPER shall not transfer, convey, assign or otherwise relinquish or release its respcatrsilaility for the operation and maintenance of its Disposal System until a permit has been reissued to the JE Et C)Pf R':s successor. by each The :DEVELOP ER sharp pa4taa-ide in the Declaration and Association Bylaws that the Disposal Syste. appurtenances thereto are part of the cominon elements and shall thcr•e:-Ater he properly mainta operated i.n conformity with taw and the previsions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment collection and disposal system as a common element which will receive the hig,lacst prinrity fair expenditures by the Association except far Federal. State, and local taxes -and in -nee. The, DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal Svstt rrr will naintained out of the common experts. In order tts assure that there shall be funds rta ily aavaital ie to the Disposal System, beyond the rnutine operation and maintenance the Deelir aatitata and Association Bylaws shall provide that a fund he created out of the common expenses. Such fund shall lie separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budfct. h. ha the even) the cornraatan cx a nse allocation and separate fund are not aadequaate and rnaaintenance. c. f the Disposal System, the Declaration and Association Bylaws shall provide for 1 assessments to cover such necessary casts. There, shall be no limit on. the amount of su assessments, and the Declaration and Bylaws shall provide that such special assessments can be mase as necessary at a.ny time fix a wastewater collection system and wastewater treatment and/or r disposal facility provided by any city town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development.. the DEVELOPER shall take such action as is necessary to cause the existing and feature wastewater of the Development to be accepted and dtschaarg,ed into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary eaasetncnts as the governmental unit niaay require as condition of accepting the Development's wastewater. S, Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the .Association to enter into voluntary dissolution without having made adequate provision fot° the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. a). The agreements set forth in numbered paragraphs 1. 2, 3, 4, 5. ti., 7, and ft above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER R for the construction, anaintenancea repair and operation of the Disposal System. 10. A copy of this agreement shall he filed aat tlae lit gasser cif Deeds in the Couanty iesf where the Declaration is filed and :in the offices of the Secretary of State of North Carolina with the r1,.rticles of Incorporation cif the Association fl*1 WfFN"FSS 'WI-€ERE.t;)1 , dais aagr►craaerat rvaas c.,.xecaatcit representative of the parties hereto on the day and year w FOR THE ENVIRONMENTAL MANACEM1:q,aN1 COMMISSION tlaatei duly authorised ae I Hare on indicate:, gtt Hon Name o " E OPE1 als fay t by each Print Nanat' a at,