Loading...
HomeMy WebLinkAboutWQ0032204_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality September 27, 2007 Mr. Brian Nolan, President Neighbors Restorations, LLC 6000 Monroe Road, Suite 350 Charlotte, NC 28207 Subject: Permit No. WQ0032204 Brownstone on Bruns Wastewater Collection System Extension C-MU TRACKING #600-07-562 Mecklenburg County, North Carolina • Dear Mr.Nolan, In accordance with your application received on September 7, 2007, we are forwarding herewith Permit No. WQ0032204, dated September 27, 2007, to Neighbors Restorations, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from .the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. None Carolina Naturally Mooresville Regional Office 6I0 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-I699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper 4 Mr. Nolen Page 2 September 27, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 800 linear feet of 8-inch gravity sewer and the discharge of 4,750 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system, pursuant to the application received September 7, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utilities WWTP (Irwin Creek NPDES No. NC0024945) prior to being discharged into the receiving stream. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes 143-215.6A to 143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit if any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins cc: Mecklenburg County Land Use and Environmental Services Agency (LUESA) Steve Miller, CMU Philip Edward, Mecklenburg County Mooresville Regional Office, Collections System Permit Files David Braun, Evans, Mechwart, Hamilton, and Tilton, Inc. Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permittingof Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may- be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General 'Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatmentof all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 27th day of September, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullin ; Direct r Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032204 3 PFast Track Engineering Permit No. W00032204 September 27, 2007 Owner/WQCS Brian Nolan, President Neighbors Restoration, LLC 6000 Monroe Road, Suite 350 Charlotte, NC 28207 Certification WVVfP/WQCS Steve Miller Charlotte Mecklenburg Utilities 510 Brookshire Blvd Charlotte, NC 28216 PE David Braun Evans, Mechwart, Hamilton and Tilton, Inc. 8307 University Executive Park Drive, Suite 231 Charlotte, NC 28262 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that providesproof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Brownstone on Bruns, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted: June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collectiori system extension prior to completion -of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. poOF NORTH CAROLINA OUNTY OF MECKLENBURG Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (dl) and entered into this 6th day of September, 2007, by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Neighbors Restorations, LLC, a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in Mecklenburg County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as Brownstone on Bruns (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the Brownstones on Bruns Townhome Owners Association, Inc. (hereinafter. Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. 'I7 In r 6. flER 7 fV) WY) e.DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL MANAGEMENT C e. ISSION CoLcct/ /71• sc/ f,/$ ..Di,f c-7 _ I ✓i of tier4,-- -4/77 ,De Neighbors Restorations, LLC Name ofDEVELOPER By: tzQir- /fr/. (Signature) Brian H. Nolen, President Print Name and Title reriden (Date) L'!l1) T d. TOT !Vl Th'! Permit Number WQ0032204 Central Files: APS SWP 09l26/07 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 4750 Facility Facility Name Brownstone on Bruns Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Owner Type Neighbors Restorations LLC Non -Government Pates/Events Orig Issue App Received Draft Initiated 09/26/07 09/07/07 Regulated Activities Apartment complex Condominium Wastewater collection Outfall NULL Scheduled Issuance Owner Affiliation Brian Nolen, President Public Notice Issue Effective Expiration 09/26/07 09/26/07 Reauested/Received Events Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin APP'LICATJON for GRAVITYS " V RS, PUMP STATIONS,, ANLt FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner: Neighbors Restorations, LLC Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Brian Nolen, President Signing Official Name and Title (Please review 15A NCAC 2H ,0206(b) for suthori.zed signing offici Application Number: (to be completed by DWQ) 1 c. The legal en t� who will own this system is: ndividual Federal 0 Municipality 0 St 1 d. 6000 Monroe Road, Suite 350 ding Address orth Carolina 1h. (704) 531-935(704) 531-9354 Telephone Facsimile 2. Project (Fa ci ity) Information: 2a. Brownstone on. Bruns Brief Project Name (perm wiil refer Contact Person: 3a, David Braun, P.E., Design Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (704)548-0333 __mm......_. 3c, dbraun@emht Phone Number E-mail If Modification, Permit No.: Private Partnership 0 Corpo Charlotte City 28212 Zip Code Brian.Nolen@gachlaw.com E-mail ltion 0 Othe 2b. Mecklenburg County Where Projec to this name Project is New 0 Modification (of an existing permit) For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(16-11) that has already been included in the original permit. 2. Owner is 0 Public (skip to Item B(3)) 2a. If private, applicant will be: Private (go to Item 2(a)) 2b, if sold, facilities owned by a (must choose 0 Retaining Ownership (i.e. store, church, single office, etc,) or 0 Public Utility (Instruction III) 0 Leaning units (lots, townhomes, etc. - skip to Item B(3)) ( Homeowner AssociDeveloper (Instruction IV) Selling units (lots, townhomes, etc. - go to Item B(2b)) Charlotte Mecklenburg Utilities Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project Irwin Creek Wastewater Treatment Plan 4b. NC0024945 Name of WWTF WWTF Permit No. .Charlotte Mecklenburg Utilities 5b. B 'O Gravity '5c. Unknown Owner of Downstream Sewer .Receiving Sewer Size © Force Main Permit Number of Downstream The origin of this wastewater is (check all that apply): 0 Residential Subdivision Apartments/Condominiums 0 Mobile Home Park 0 School 0 Restaurant 0 Office ewater to be olio previously per 0 Car Wash O Institution O Hospital O Church O Nursing Home O Other (specify): ed for this particular project: d allocations If the permitted flow is zero, indicate why: O interceptor Line - Flow will be permitted in subsequent pet O Flow has already been allocated in Permit No, O Rehabilitation or replacement of existing sewer with no ne known 100 % Domestic/Commercial °io industrial °6 Other (specify): hat connect to this line ow expected FTA. 0 /03 - Rev. 3 04/05 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 1 j i 10 lli = Z I-- Z ....... Z 0 Q M ce 0 LL Z m12. r4 LV a Im j14. '15. 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). 25 Residential Units X 190 gpd/unit = 4,750 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 8 800 Gravity [ i I ' ENTER TOTAL LINE LENGTH IN MILES; 0.15 miles 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID ; (self chosen - as shown on E Design Flow plans for cross-reference) j (MGD) Operational Point GPM @ TDH Power Reliability Option (1- dual line feed; 2- permanent generator w/ATS; 3- portable generator wltelemetry; 4-wet well storag!) —4 I { Does the sewer system comply with the Minimum I Mains (latest version), the Gravity Sewer Design Criteria for the Fast Track Permitting of Pump Stations and Force Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? the pertinent minimum design criteria or regulation and indicate why a SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS WITH YOUR APPLICATION ►I Yes ❑ No If no, please reference i variance is requested. PERTINENT TO THE VARIANCE :13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? 0 Yes ❑ No ® N/A ►1. Yes • No • NIA ■ N/A @ Yes • No Does this project involve aerial lines or siphons? Check if yes: ❑ Theseiines_y iILbe_consideredMoh.nrlodty and must.be checked_once.evenrsixmonths Does this project have gravity sewer lines designed at minimum slopes? co Be aware that the Division will not accept installed lines more than 1 O% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 VPLICATJON for CRAVITY SEWERS, PUMP S`f"ATIONS, AND FORCE MAINS ()g PAGE 5 Divsons guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 TRACT( SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets asary). Ths document is avalable from our web site or by contacting the appropriate Division ofWater Quality l office see instructions for addresses OR indicate the follown : tream Classification is not needed because all parts othe project are at least 100 feet away from any down slope rbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. z Location ID on Map (self chosen - as shown on map for cross-reference) Name of Waterbody County Waterbody Strea River Basin Index Submit the tt.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: Waterbody Classification 1, Brian Nolen, attest that this application for Brownstone on Bruns, has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215, 6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25,000 per violation. 4sa +oft 'T` Signing Qfficiai"Signature Professional Engineer's Certification. I attest that this application for Brownstone on Bruns, has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the! Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1„ 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215,6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor Wh1ch m y include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. David Braun, PE Professional Engineer Name 2b. Evans,Mechwart, Hamilton, and Tilton Inc. Engineering Firm 2c, 8307 University Executive Park Drive, Suite 23 Mailing Address 2d, Charlotte City State Zip 2g.1704)n( mht.m 548-0333 2h, (704) 5�t8�-0334 2i. dbraun f: corn Telephone Facsimile E-mail Seal, Signature & Date FTA 02/03 - Rev, 3 04/05 crx CHARLOTTE. CHARLOTTE-MECKLENBURG UTILITIES April 4, 2007 Mr. Dave Braun EMH&T 8307 University Executive Park Drive - Suite 231 Charlotte, NC 28262 SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE ROOFTOP ON BRUNS TAX PARCEL. #071-074-45 C-MU TRACKING# 600-07-562 Dear Mr. Braun: In response to your request, a flow acceptance study of the subject site has been completed and the following has been determined Upon completion and acceptance of all necessary sewer lines, .Charlotte -Mecklenburg Utilities agrees to accept the gravity sewage flow of 4,750 gallons per day (25 residential units x 190 gpd/unit) from this project for.•transmission to the Irwin Creek Wastewater Treatment Plant; NPDES permit number NC0024945, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge • permit from the appropriate local, State, or Federal Agency, whichever might have control. Please see • attached basin map. Upon completion and acceptance of all necessary water mains to serve the subject site, Charlotte- - -Mecklenburg Utilities agrees to fumish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, dated October 2005. (WSMP # 05-01702 & PWS ID # 0160010), on file with.the Public Water Supply Section of NCDENR. However, Charlotte -Mecklenburg Utilities cannot guarantee a -constant pressure or quality of flow. This agreement is also contingent upon approval by the Division of Environment, Health, and Natural Resources. Charlotte -Mecklenburg Utilities does not expect any of the above conditions,to preclude water or sewer •service to the subject site. However,, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg Utilities system is accepted on a first come, first served basis. If you have any questions, you may contact me at (704) 391- 5129. Sincerely, Barbara Gross Engineering Assistant - New Services Section CHARLOTTE-MECKLENBURG UTILITIES Customer Service Division • New Services Section www.cmutilities.com 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 Fax: 704/393-2219 Hard Creek WWTP ay o 400.4. Charlotte -Mecklenburg Utilites WWTP Service Areas with Basins 'fopolone - Seversvil Charlotte as't (NC) " `opo Map Page 1 of 1 0.3 0.6 0.9 1.2 1.5 km 0 0.1 0.2 0.3 0.4 0.5 mi UTM 17 512602E 3899364N (NAD27) Seversville School, USGS Charlotte East (NC) +t uadrangle Projection is UTM Zone 17 NAD83 Datum 6=0.00 http://vyww.topozone.com/printas iat-35.23905&loin=- C1.8615&s-48&csize=m&u-4&lay... 9/Cl2007 NEIGHBORS RESTORATIONS, LLC 6000 ,Wonroe Road, Suite 350 Charloae, „North Carolina 28212 (704) 604-4449 September 10, 2007 North Carolina Dept. of Environment & Natural Resources Attention: Mr. Rob Krebs, Water Protection Section Supervisor Division of Water Quality 610 E. Center Ave., Suite 301 Mooresville, North Carolina 28115 Mr. Krebs, I am writing regarding the "Brownstones on Bruns" town home project at the southwest corner of Sumter and Bruns Avenues. EMH&T recently submitted the sewer application fee, and we inadvertently underpaid fees in the amount of $80.00. Enclosed with this letter is a check for $80.00. I apologize for the confusion. Thank You, 614 Brian H. Nolen, President cc: Michael J. Doney Michael Swain Zac Barnett Rob Eggers • 4EP NC DENR MR0 rfoce Water Protection Letter of Transmittal To: Department of Environmental and Natural Resources (DENR) Division of Water Quality 610 E. Center Avenue, Suite 301 Mooresville, North Carolina 28115 SEP % 2007 NC DEN M O DWQ-Surface Water Prof cflon From: Wesley A. Smith, E.I. Date: September 7, 2007 Job no.: 2006-1831 Re: Brownstone on Bruns We are sending you herewith via: Courier The following items: Copies 2 2 Date Number of sheets 5 Ixl copies Description Ixl U.S. Mail Fed, Ex. I 1 UPS originals I [other] Fast -Track Sewer Application (1 Original and 1 Copy) Application Check ($400.00 #2072) Developer's Operational Agreement (1 Original and /.Copy) 2 Flow Acceptance Letter USGS Topographic Map These are transmitted as checked below:. IxI for approval II for your file for execution / si.natures Il as requested { 1 for review & comment [other] Remarks: If there are any questions or comments please do not hesitate to give me a call at 1-704-548-0333. Thanks ! ! ! ! Cooi s To: Signed: If enclosures are not as noted, kindly notify us at once, M C M X X V sley A. Smith, E.I. 8307 University Executive Park lDwe, Suite 231, Charlotte, NC 28262 • Phone 704.548.0333 • Fox 704,548.0334 Coo np41s • 010: nnot • :noiortoPois • ChorroPore ernhLcorn