HomeMy WebLinkAbout820144_Routine_20210830cOter—/° �a-r
acility Number
abivision of Water Resources,
0 Division of Soil and'1Y,ater Conse
D Other Agency
anon;
Type of Visit: G Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance
Reason for Visit: S Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access
Date of Visit: ,30.---p' Arrival Time:
7 3D
Farm Name: _, S& .errs (2r044
Owner Name: Vjyn- Lip Q Pc Cr
Departure Time: ; pp I County* J " -- Region: F
gartrl—
Mailing Address:
Physical Address:
Facility Contact: �F griftW0 //167ets
Onsite Representative:
Certified Operator:
Back-up Operator:
Location of Farm:
Owner Email:
Phone:
Title:
Latitude:
Phone:
Integrator: aim
Certification Number:
Certification Number:
Longitude:
Discharges and Stream Impacts
1. Is any discharge observed from any part of the operation?
Discharge originated at: ❑ Structure ❑ Application Field ❑ Other:
a. Was the conveyance man-made?
b. Did the discharge reach waters of the State? (If yes, notify DWR)
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does the discharge bypass the waste management system? (If yes, notify DWR)
2. Is there evidence of a past discharge from any part of the operation?
3. Were there any observable adverse impacts or potential adverse impacts to the waters
of the State other than from a discharge?
❑ Yes 214o ❑NA ❑NE
❑ Yes ❑ No ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
❑ Yes 04 ❑ NA ❑ NE
❑ Yes 12-34 ❑NA ❑NE
Page 1 of 3
2/4/2015 Continued
Facility Number: ,2. - /.tl L
Waste Collection & Treatment
4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes [ No ❑ NA ❑ NE
a. If yes, is waste level into the structural freeboard? ❑ Yes 1:2/No ❑ NA ❑ NE
Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6
Identifier:
Spillway?:
Designed Freeboard (in):
Observed Freeboard (in):
ay
Date of Inspection: D-#2-2:i -/
5. Are there any immediate threats to the integrity of any of the structures observed?
(i.e., large trees, severe erosion, seepage, etc.)
6. Are there structures on -site which are not properly addressed and/or managed through a
waste management or closure plan?
If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR
7. Do any of the structures need maintenance or improvement? [] Yes ❑ No ❑ NA ❑ NE
8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes dNo ❑ NA ❑ NE
(not applicable to roofed pits, dry stacks, and/or wet stacks) 1
9. Does any part of the waste management system other than the waste structures require ❑ Yes 0 No ❑ NA ❑ NE
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes 1No ❑ NA ❑ NE
maintenance or improvement?
11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes [e\lo ❑ NA ❑ NE
❑ Excessive Ponding ❑ Hydraulic Overload 0 Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.)
❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil
❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area
Jr*ttn Kaiak- /0C,
12. Crop Type(s):
13. Soil Type(s):
3o /Z /41 /& ae..a
❑Yes IZ(No ❑NA El NE
❑ Yes [/(No ❑ NA ❑ NE
14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes Ill<To ❑ NA ❑ NE
15. Does the receiving crop and/or land application site need improvement? ❑ Yes Q No ❑ NA ❑ NE
16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes 211To 0 NA 0 NE
acres determination?
17. Does the facility lack adequate acreage for land application? ❑ Yes El<To ❑ NA 0 NE
18. Is there a lack of properly operating waste application equipment? ❑ Yes IZ-No ❑ NA ❑ NE
Required Records & Documents
19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes IZ"No ❑ NA ❑ NE
20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes [o ❑ NA ❑ NE
the appropriate box.
❑WUP ❑Checklists ❑Design ❑ Maps ❑ Lease Agreements ❑Other:
21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes Q No ❑ NA ❑ NE
O Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code
❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey
22. Did the facility fail to install and maintain a rain gauge? ❑ Yes No ❑ NA ❑ NE
23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes No ❑ NA ❑ NE
Page 2 of 3 5/12/2020 Continued
Facility Number: ;-, - / yq
Date of Inspection: f 3O
24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check es
the appropriate box(es) below.
❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels
on -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
❑ NA ❑NE
❑ NA ❑ NE
is - aoi8- 4-
26. Did the facility fail to provide documentation of an actively certified operator in charge?
27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification?
Other Issues
28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document
and report mortality rates that were higher than normal?
29. At the time of the inspection did the facility pose an odor or air quality concern?
If yes, contact a regional Air Quality representative immediately.
30. Did the facility fail to notify the Regional Office of emergency situations as required by the
permit? (i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below.
❑ Application Field ❑ Lagoon/Storage Pond ❑ Other:
❑ Yes
❑ Yes
❑ Yes
❑ Yes
❑ Yes
❑ Yes
32. Were any additional problems noted which cause non-compliance of the permit or CAWMP?
33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative?
34. Does the facility require a follow-up visit by the same agency?
❑ Yes
❑ Yes
❑ Yes
dNo ❑ NA ❑ NE
[] No ❑ NA ❑ NE
[] No ❑ NA ❑ NE
[] No ❑ NA ❑ NE
12 No ❑ NA ❑ NE
Er(lo ❑ NA ❑ NE
[]No
[/] No
No
❑ NA
❑ NA
❑ NA
❑ NE
❑ NE
❑ NE
Comments (refer to question #): Explain any YES answers and/or any additional recommendations
Use drawings of facility to better explain situations (use additional pages as necessary).
or any other comments
f7 ritzy O '- Lyon. 1JZYt^r r
Reviewer/Inspector Name:
Reviewer/Inspector Signature:
,5Fr
Phone: 9473d3---016f
Date: �'✓TO—O0�/
Page 3 of 3 5/12/2020