HomeMy WebLinkAbout20201102 Ver 1_Updated Plan Info_20211027Strickland, Bev From: Jessica McDonald <jmcdonald@ramaker.com> Sent: Wednesday, October 27, 2021 3:45 PM To: David.E.Bailey2@usace.army.mil Cc: Elliott York; Homewood, Sue Subject: [External] RE: NWP39_SAW-2019-01884 - Proposed Changes to Permit for the 174P0173 (MAY) site (10142260) - R&A #44468 Attachments: 132151_NCC019_CD (11) 2021-10-25.pdf; NWP39_SAW2019-01884 NWP 39.pdf Follow Up Flag: Follow up Flag Status: Flagged CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hi David, Since your office issued the update below, some other scope changes have come up. A portion of the proposed utility route that was previously planned to have overhead lines over the stream crossing is now proposed to be directionally bored under the stream as detailed in the attached CDs (sheet C-2.1). Could you let me know if the attached permit will still apply? Also let me know if you need any additional information. Thank you for your guidance! Jessica RAMAKER Jessica McDonald Environmental Specialist RAMAKER I Employee -owned 855 Community Dr, Sauk City, WI 53583 D (608) 644-2259 M (608) 341-7892 www.ramaker.com I jmcdonald@ramaker.com From: Bailey, David E CIV USARMY CESAW (USA) <David.E.Bailey2@usace.army.mil> Sent: Thursday, April 22, 2021 2:43 PM To: Elliott York <eyork@ramaker.com>; Sue.homewood@ncdenr.gov Cc: Jessica McDonald <jmcdonald@ramaker.com> Subject: RE: NWP39_SAW-2019-01884 - Proposed Changes to Permit for the 174P0173 (MAY) site (10142260) - R&A #44468 CAUTION: This email originated from outside our organization. Hi Elliott, and thanks for you email. Note that I also received Jessica's call about this project. My apologies for the delay in my response. I do remember the site and the NWP 39 verification we issued on 10/9/2020. My understanding from your description and updated plans (attached) is that impacts have gone from 46 If (0.005 acre) of stream and 0.04 acre wetlands to proposed impacts of ^'52 If (0.006 acre) stream and 0.07 acre wetlands. The reason for the increase in the proposed impacts is a change in the access road width from 20 ft to 25 ft. Based on our case -by -case review, we have determined that the amended project still fits NWP 39, does not require compensatory mitigation, and can proceed as you proposed in compliance with the NWP 39 terms and conditions (attached). Note that, per our 2017 NWP 39 authorization and its expiration due to the issuance of the 2021 NWP 39, construction of the authorized impacts must be complete no later than 3/14/2022. Please let me know if you have any questions. -Dave Bailey David E. Bailey, PWS Regulatory Project Manager US Army Corps of Engineers CE-SAW-RG-R 3331 Heritage Trade Drive, Suite 105 Wake Forest, North Carolina 27587 Office: (919) 554-4884, Ext. 30. Mobile: (919) 817-2436 Fax: (919) 562-0421 Email: David.E.Bailey2@usace.army.mil We would appreciate your feedback on how we are performing our duties. Our automated Customer Service Survey is located at: https://regulatory.ops.usace.army.mil/customer-service-survey/ Thank you for taking the time to visit this site and complete the survey. From: Elliott York <eyork@ramaker.com> Sent: Friday, April 9, 2021 1:09 PM To: Bailey, David E CIV USARMY CESAW (USA) <David.E.Bailey2@usace.army.mil>; Sue.homewood@ncdenr.gov Cc: Jessica McDonald <jmcdonald@ramaker.com> Subject: [Non-DoD Source] NWP39_SAW-2019-01884 - Proposed Changes to Permit for the 174P0173 (MAY) site (10142260) - R&A #44468 Good afternoon Mr. Bailey and Ms. Homewood, I hope this email finds you doing well. I'm writing in regard to a proposed change since NWP39_SAW-2019-01884 was issued on October 9, 2020. In summary, the proposed access road that traverses the wetland has been widened by 2 feet. How would you like to receive this revised information? Is a new permit application necessary or can we submit the changes via email or another avenue? I have attached the revised construction drawings for your reference and review. Please let us know if there are any questions or concerns and we'll be happy to address them. Kindest regards, 2 RAMAKER Elliott York I Environmental Specialist RAMAKER I employee -owned 855 Community Dr, Sauk City, WI 53583 0 (608) 643-4100 D (608) 643-2233 www.ramaKer.com I eyork@ramaker.com 3 Permittee: Address: U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id. SAW-2019-01884 County: Guilford U.S.G.S. Quad: NC-McLeansville GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERIFICATION City Switch II -A, LLC Attn: Jason Groseclose 1900 Century Place, Suite 320 Atlanta, GA 30345 Size (acres) -7.46 Nearest Town McLeansville Nearest Waterway UT to North Buffalo Creek River Basin Cape Fear USGS HUC 03030002 Coordinates 36.1149, -79.7088 Location description: The project area is located on the south side of Camp Burton Road, approximately 0.25 mile east of its intersection with Rankin Mill Road, at 4226 Camp Burton Road, in McLeansville, Guilford County, North Carolina. Description of projects area and activity: This verification authorizes the permanent discharge of fill material into 46 linear feet (0.005 acre) of stream channel (all a loss of waters of the US) and 0.04 acre of riparian non-riverine wetlands, necessary for the installation of one road crossing for construction access and long-term maintenance of a cellular tower. Applicable Law(s): © Section 404 (Clean Water Act, 33 USC 1344) ❑ Section 10 (Rivers and Harbors Act, 33 USC 403) Authorization: NWP 39. Commercial and Institutional Developments REMARKS: The use of this permit has been verified After -the -Fact. SEE ATTACHED NWP GENERAL, REGIONAL, AND/OR SPECIAL CONDITIONS Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the enclosed Conditions, your application signed and dated 8/27/2020, and revised information sent via email on 10/9/2020, and the enclosed plans Sheet Numbers C-1, C-2.1, and C-9.3. Any violation of the attached conditions or deviation from your submitted plans may subject the permittee to a stop work order, a restoration order, a Class I administrative penalty, and/or appropriate legal action. This verification will remain valid until the expiration date identified below unless the nationwide authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified nationwide permit. If the nationwide permit authorization expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the nationwide permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon the nationwide permit, will remain authorized provided the activity is completed within twelve months of the date of the nationwide permit's expiration, modification or revocation, unless discretionary authority has been exercised on a case -by -case basis to modify, suspend or revoke the authorization. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements. For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (CAMA), prior to beginning work you must contact the N.C. Division of Coastal Management. This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State or local approvals/permits. If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of Engineers regulatory program, please contact David E. Bailey at (919) 554-4884 X 30 or David.E.Bailey2(ausace.army.mil. % Date: 2020.10.09 15:10:19 -04'00' Corps Regulatory Official: A"" Expiration Date of Verification: 03/18/2022 Date: 10/09/2020 The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete the Customer Satisfaction Survey located at http://corpsmapu.usace.army mil/cm_apex/f?p=136:4:0. Copy fumished: Nick Creidler, Headwater Environmental, Inc., 1121 Military Cutoff Road, Suite C #306, Wilmington, NC 28405 Sue Homewood, NCDEQ-DWR, 450 W. Hanes Mill Rd, Suite 300, Winston-Salem, NC 27105 DRAINAGE NARRATIVE: THE PROPOSED SITE DISTURBANCE FOR THIS CELL TOWER SITE INCLUDES A 808' ONSITE ACCESS ROAD AND TURNAROUND, A 80'X80' NON -VEHICULAR GRAVEL COMPOUND, AND THE LANDSCAPE AREA SURROUNDING THE 80' X 80' GRAVEL COMPOUND. THE TOTAL PROPOSED DISTURBED AREA IS 40,487.52 SF (0.929 AC). THE TOTAL PROPOSED DISTURBANCE AREA IS LESS THAN 1 ACRE. A GRADING PERMIT IS NOT REQUIRED. THIS AREA IS CURRENTLY UNDEVELOPED. THE PRE -DEVELOPMENT FLOW RATE IS BASED ON THE RATIONAL METHOD (Q=CiA), C=0.35, i=0.304 IN/HR, A=7.47 AC FOR A 100-YR 24-HR DESIGN STORM PER NOAA ATLAS 14 POINT PRECIPITATION DATA. THE POST -DEVELOPMENT FLOW RATE IS CALCULATED USING THE RATIONAL METHOD WITH A WEIGHTED 'C' VALUE OF 0.38. THE PRE -DEVELOPMENT IMPERVIOUS COVER HAS BEEN TREATED AS 0 SF AND THE POST DEVELOPMENT IMPERVIOUS COVER IS 16,455.34 SF. THE PARENT PARCEL IS 325,257.31 SF. THE PROPOSED POST DEVELOPMENT IMPERVIOUS COVER IS 5.1% Qpre = 0.795 CFS Qpost = 0.863 CFS THE PROPOSED DEVELOPMENT WILL RESULT IN AN INCREASE IN STORMWATER RUNOFF OF 0.068 CFS. WATERSHED INFORMATION: NORTH BUFFALO CREEK THE NORTH BUFFALO CREEK SUBWATERSHED (HUC12: 030300020105) IS IN THE REEDY FORK WATERSHED (HUC10:0303000201) WITHIN THE HAW RIVER SUBBASIN (HUC8: 030300002) WHICH IS A PART OF THE CAPE FEAR RIVER BASIN (HUC6: 030300). NOTE: ACCESS DRIVE SHALL CONSIST OF AN "ALL- WEATHER" GRAVEL SURFACE. N/F CHARLOTTE FOGLEMAN PARCEL ID: 115371 ZONED: AG —AGRICULTURAL DB R 6723 PG 30 WETLAND LIMITS EXISTING 12" RCP EXISTING TREE LINE PROPOSED 80' x 80' FENCED GRAVEL COMPOUND PROPOSED 100' x 100' LEASE PARCEL PROPOSED PARKING AND TURNAROUND AREA PARENT TRACT OOVERALL SITE PLAN SCALE: 0100 C N/F DAVID W. & SHIRLEY TATUM PARCEL ID: 115373 ZONED: AG —AGRICULTURAL N/A PROPOSED 20' WIDE ACCESS & UTILITY EASEMENT PARENT PARCEL N/F LAWRENCE B. MAY PARCEL ID: 115372 ZONED: AG —AGRICULTURAL DB 2602 PG 384 PROPOSED AT&T 435 SQ FT LEASE AREA PROPOSED 220' SELF SUPPORT TOWER 50 150 200' N/F SHERRY E. CA EY PARCEL ID: 115356 ZONED: RS-30 DB 4907 PG 1711 1 "=100' N/F THE CITY OF GREENSBORO PARCEL ID: 217968 ZONED: PI —UNKNOWN DB R 8059 PG 2437 EXIST. STREAM WETLAND TABLE: STREAM LENGTH = 390' (PERENNIAL, WITHIN PARCEL) STREAM WIDTH = 3' +/- LENGTH OF STREAM IMPACTS 40' (CULVERT) NOTES: 1. SEE LEGEND, SITE DATA, AND GENERAL NOTES ON SHEETS GN-1. 2. TOWER LATITUDE, LONGITUDE & ELEVATION MEET FAA"1-A" ACCURACY REQUIREMENTS. 3. PROPOSED SELF-SUPPORT TOWER. CENTER OF TOWER: LATITUDE: NORTH 36°06'50.39" (36.113997) NAD 83 LONGITUDE: WEST-79°42'32.86" (-79.709128) NAD 83 GROUND ELEVATION @ 747.1' A.M.S.L. 4. THE PERPENDICULAR DISTANCES FROM THE CENTER OF PROPOSED TOWER TO PARENT TRACT BOUNDARY LINE WERE ESTABLISHED FROM ACTUAL FIELD MEASUREMENTS AND OBSERVATIONS PERFORMED BY POINT TO POINT LAND SURVEYORS 2/18/2019. AND ARE AS FOLLOWS: NORTH: SOUTH: EAST: WEST: 804.3'± 228.6'± 197.4'± 111.8'± 5. EXISTING FEATURES SHOWN ARE BASED ON FIELD SURVEY BY POINT TO POINT LAND SURVEYORS PERFORMED ON 2/18/2019. 6. THIS PLAN IS NOT A BOUNDARY SURVEY. PROPERTY BOUNDARY INFORMATION SHOWN IS FOR REFERENCE ONLY. POINT TO POINT LAND SURVEYORS DID NOT VERIFY BOUNDARY AS PART OF THIS SURVEY. DEED BEARING AND DISTANCE IN PARENTHESIS. 7. NO WETLANDS INVESTIGATION WAS PERFORMED AS PART OF THIS SURVEY. 8. NO INVESTIGATION OF THE PRESENCE OF HAZARDOUS MATERIALS WAS PERFORMED AS A PART OF THIS SURVEY. 9. UTILITIES SHOWN PER FIELD LOCATIONS FROM ABOVE GROUND INSPECTION OF THE SITE AND UTILITY MARK -OUTS IN THE FIELD. UTILITIES THAT EXIST MAY NOT BE SHOWN. 10. CONTRACTOR TO VERIFY POWER & TELCO DEMARCS WITH UTILITY PROVIDERS PRIOR TO BIDDING PROJECT. 11. NO WATER, WASTEWATER, OR SEPTIC UTILITIES ARE REQUIRED FOR THIS DEVELOPMENT. FLOOD ZONE NOTE: NO PORTION OF THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD AREA AS PER F.I.R.M. COMMUNITY PANEL NO. 37107896003 DATED 6/18/2007. B+T C ITY SWITCH M.OURTAIN, OIL W tz 0 0 U 0 ra 0 O PROJECT NO: 132151 CHECKED BY: DLS ISSUED FOR: REV M1E ORM 01/02/20 OEs 06/04/20 uns fi 07/0B/20 PAS DESCRIPTION FlNPL FlNPL FlNPL B&T ENGINEERING, INC. C-4171 Expres 6/30/20 THIS DOCUMENT IS PRELIMINARY IN NATURE AND IS NOT A FINAL, SIGNED AND SEALED DOCUMENT iforairaviaiiialWr OVERALL SITE 1 PLAN II SHEET NUMBER: C — 1 MAT iu LINE A (8o PROPOSED 20' WIDE \ ACCESS & UTILITY EASEMENT N PROP. UNDERGROUND \ \ ELEC. \ \\ \ \ PROP. UNDERGROUND \ \ \ TEL\0 o \ \ \ \ \ \ \ \ \ PROPOSED AT&T 240 \ -3�SQ. FT. LEASE AREA \ �r \ 1 \ LiiFG=745.7 \ \ \ \ \ \ \ FG=747.2 �I49 \ TOC=747.48 1 \ \ Ai12' DOUBLE— \ �\ ® SWING GATE •�/ �`•`, \\ \ FG=7477 \ 72 \ FG=749.0 \mom \ \ FG=748.4 I�1 E \ 2 \\ \\ GRAVEL Fl . FG-749\W\\ \ COMPOUND \9P \ PROPOSED A V �V V A\ H-FRAME \\ \ \\ am2s�\ PROPOSED 220' SELF C. SUPPORT TOWER\ \ \ \ F \ \ \ \ \ \ \ \ FG=745.7 "'F\ PROPOSED 50' x 50' \ \ \ \ \ \ \ \ �o FENCED COMPOUND \ \ \ \ \ \ \ \ \ \ �• 3e, PROPOSED 100' x 100' \ \ \ \ \ ♦ PROPOSED 197 LF± 12' WIDE GRAVEL ACCESS ROAD FG=744.7 FG=745.2 FG=747.1 FG=747.6 FG=747.1 FG=748 e LEASE AREA ASS LP LP 0 OPROPOSED IMPROVEMENTS PLAN SCALE: wommmmoi 1"=40' 0'• 20 40 • 60 80' onservative scaled measurement of wetland impact NOTES: ACCESS DRIVE SHALL CONSIST OF AN "ALL- WEATHER" GRAVEL SURFACE. REFER TO SHEET E-2 FOR CARRIER GROUND EQUIPMENT INFORMATION. WETLAND LIMITS PROPOSED SILT FENCE (TYP) TOTAL 230 LF± WETLAND LIMITS THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING ON THE WORK CONTAINED \M THIN THIS DESIGN PACKAGE. DISCREPANCIES AND OMISSIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. LEGEND 745 ,-y FG=745.9 INDICATES EXISTING CONTOUR INDICATES FINISHED GRADE ELEVATION R EXISTING REMOVE MATH (Tpp EEC A PROPOSED FG=725.9 FG=725.5 � 26' 12" RCP G=725.8 UNDERGROUND TELCO rAtl ///736 735 - 733 731 -- PROPOSED 20' WIDE ACCESS & UTILITY EASEMENT PROP. UNDERGROUND ELEC. e-� INSTALL TEMPORARY INLET PROTECTION INSTALL 40 L.F. 18" ADS N-12 S.D. PIPE WITH END SECTIONS (OR APPROVED EQUAL) (SEE DETAILS 1, 2 SHEET C-9.3) FG=726.3 WETLAND LIMITS OPROPOSED IMPROVEMENTS PLAN SCALE: 1' 40' 20 40 60' 80 738 B+T CfTYSWITCH 1151 MOIDTTAK LTD. PROJECT NO: 132151 CHECKED BY: DLS ISSUED FOR: REV OME ORWN 01/02/20 016 06/04/s0 uns fi 02/06/20 AU5 OESCRIP11ON FlNPL FlNPL FlNPL B&T ENGINEERING, INC. C-4171 Expres 6/30/20 THIS DOCUMENT IS PRELIMINARY IN NATURE AND IS NOT A FINAL, SIGNED AND SEALED DOCUMENT IMPROVEMENTS PLAN 1 PROPOSED SHEET NUMBER: C-2.1 727 726 725 724 723 722 721 20' ACCESS/UTILITIES EASEMENT PROPOSED TOP OF DRVEWAY (MAINTAIN 1' MIN COVER OVER TOP OF PIPE) EXISTING DRIVEWAY SURFACE1 FG=725.7 T.O.P.=724.50 IE=722.80 PROPOSED 18° ADS N—I2 HOPE PIPE W/ END SECTIONS OR APPROVED EOUAL, 20% STREAMBED BURIAL EXISTING 12° RCP STORM DRAIN, W/ INVERT PERCHED APPROX 2° ABOVE FLOW LINE 12' 5=?% i FG=726.2 T.O.P.=724.61 . IE=722.91 EXISTING GROUND SURFACE ---- OSTORM DRAIN PROFILE SCALE: N.T.S. PIPE END SECTION (TYP) B+T 0ITYSWtT CH 1131 MOUNITAB>I;, OD. 0 U 0 .-1 PROPOSED 220' SELF SUPPOR PROJECT NO: 132151 CHECKED BY: DLS ISSUED FOR: REV DATE ORWN DESCPoanON 4 01/02/20 DLS FINAL FINAL 6 07/0B/20 224 FINu 06/04/20 LeS B&T ENGINEERING, INC. C-4171 Exp res 6/30/20 THIS DOCUMENT IS PRELIMINARY IN NATURE AND IS NOT A FINAL, SIGNED AND SEALED DOCUMENT ENGINEERING 1 DETAILS SHEET NUMBER: Action ID Number: SAW-2019-01884 County: Guilford Permittee: City Switch II -A, LLC (Attn: Jason Groseclose) Project Name: May site / cellular tower / 4226 Camp Burton Road / McLeansville / Guilford County / Commercial Date Verification Issued: 10/09/2020 Project Manager: David E. Bailey Upon completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Attn: David E. Bailey Raleigh Regulatory Office U.S Army Corps of Engineers 3331 Heritage Trade Drive, Suite 105 Wake Forest, North Carolina 27587 or David.E.Bailey2@usace.army.mil Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. I hereby certify that the work authorized by the above referenced permit has been completed in accordance with the terms and condition of the said permit, and required mitigation was completed in accordance with the permit conditions. Signature of Permittee Date User: mspeedie Oct 25 0, 0 a 132151_NCC019_CD FAN U PROJECT SUMMARY SITE NAME: NCC019 SITE NUMBER: TAX MAP PROPERTY ID: 115372 SITE ADDRESS: 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 JURISDICTION: GUILFORD COUNTY, NC TOWER OWNER: NAD83 MOUNTAIN LTD, WIRELESS DIVISION 19 YARMOUTH DRIVE, SUITE 301 NEW GLOUCESTER, ME 04260 LATITUDE: LONGITUDE: APPLICANT: CO -APPLICANT: OCCUPANCY TYPE: A.D.A. COMPLIANCE: 36.113997', 36'06'50.39" -79.709128', 79'42'32.86" CITYSWITCH 1900 CENTURY PL NE, SUITE 320 ATLANTA, GA 30345 AT&T MOBILITY UNMANNED FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION DESIGN INFORMATION A&E FIRM: B+T GROUP 840 E. McKELLIPS ROAD, BUILDING 2, SUITE 108 MESA, AZ 85203 MIKE A. SPEEDIE, PE (918) 587-4630 SURVEYOR: POINT TO POINT LAND SURVEYORS 100 GOVERNORS TRACE, STE. 103 PEACHTREE CITY, GA 30269 PH. (678) 565-4440 ELECTRIC TBD PROVIDER: XXX—XXX—XXXX TELCO TBD PROVIDER: XXX—XXX—XXXX CODE COMPLIANCE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE BUILDING/DWELLING STRUCTURAL MECHANICAL ELECTRICAL CODE IBC 2018 IBC 2018 INC 2015 NEC 2017 SITE NAME: \CC019 MBER: 10142260 / AT&T SITE ID: 174-173 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 GUILFORD COUNTY PROPOSED 220' SELF SUPPORT TOWER FINAL DEVELOPMENT PLANS VICINITY MAP n. F,e.,, H., h1c,, .n lArAfty %Yi y. ,So.balb elawns I. //.. i k.b SITE NORIO ROLINA M1kLAPITAle • OUILF u.e.,.. .1100.1 Pima OSQn S.wsnc MI *AUm.hae '0.,.1.. LOCAL MAP Rd MialItmlMW R° TFAmp 13,1 NO SCALE DRIVING DIRECTIONS DEPART PIEDMONT TRIAD INTERNATIONAL AIRPORT ON S ARRIVAL DR 0.7 MI, MERGE ONTO N TRIAD BLVD 0.3 MI, BEAR RIGHT ONTO AIRPORT PKWY 0.4 MI, KEEP STRAIGHT ONTO RAMP 87 YDS, KEEP LEFT TO STAY ON RAM PO.2 MI, TAKE RAMP ONTO JOSEPH M BRYAN BLVD 6.3 MI, MERGE ONTO BENJAMIN PKWY 1.0 MI, TAKE RAMP ONTO W WENDOVER AVE 1.0 MI, ROAD NAME CHANGES TO US-220 2.5 MI, ROAD NAME CHANGES TO US-70 1.4 MI, KEEP RIGHT ONTO RAMP0.1 MI, KEEP RIGHT TO STAY ON RAMP 98 YDS, BEAR RIGHT ONTO HUFFINE MILL RD 1.7 MI, KEEP STRAIGHT ONTO RANKIN MILL RD 0.7 MI, TURN RIGHT ONTO KEELY RD 0.3 MI, TURN LEFT ONTO LOCAL ROAD(S) 0.1 MI, ARRIVE AT NCC019. PROJECT DESCRIPTION THE PROPOSED PROJECT INCLUDES: • CONSTRUCT (1) NEW 220' SELF SUPPORT TOWER STRUCTURE. • CONSTRUCT FENCED GRAVEL UTILITY COMPOUND WITH LOCKING ACCESS GATE. • INSTALL (1) H-FRAME W/ UTILITY EQUIPMENT. • INSTALL NEW POWER & TELCO UTILITY SERVICES. • INSTALL NEW GROUNDING SYSTEM. • CONSTRUCT 14' WIDE GRAVEL ACCESS ROAD. • REMOVE/REPLACE EXISTING STORM DRAIN. DO NOT SCALE DRAWINGS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. CASE II20-08-GCCP-05794 C ITYSWIT DRAWING INDEX SHEET # T-1 GN-1 1-3 C-0 C-1 C-2.1 C-2.2 C-2.3 C-3 C-3.1 C-4 C-5 C-6 C-7 C-8 C-9 - C-9.3 C-10 C-11 E-1 E-2 E-3 E-4 E-5 E-6 E-7 G-1 G-2 - G-3 L-1 - L-2 SHEET DESCRIPTION TITLE SHEET GENERAL NOTES SURVEY OVERALL PARCEL PLAN OVERALL SITE PLAN PROPOSED IMPROVEMENT PLAN PROPOSED IMPROVEMENT PLAN COMPOUND DIMENSION PLAN WALK-IN CABINET DETAILS GENERATOR DETAILS TOWER ELEVATION & ANTENNA ORIENTATION ANTENNA CONFIGURATION RRH, ANTENNA & EQUIPMENT SPECIFICATIONS RF PLUMBING DIAGRAM DC / FIBER SYSTEM DIAGRAM ENGINEERING DETAILS FENCE, GATE & COMPOUND DETAILS SIGNAGE DETAILS ELECTRICAL SITE PLAN ELECTRICAL DETAIL PLAN ELECTRICAL NOTES UTILITY H-FRAME DETAILS ELECTRICAL DETAILS ELECTRICAL RISER DIAGRAM AT&T ELECTRICAL PANEL SCHEDULE GROUNDING PLAN GROUNDING DETAILS LANDSCAPE & IRRIGATION PLANS GENERAL NOTES THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, THEREFORE HANDICAP ACCESS IS NOT REQUIRED. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WITH NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE. POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. NO WORK SHALL COMMENCE WITHOUT THE APPROVED TOWER/ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER UNDER SEPARATE COVER. CALL NORTH CAROLINA ONE CALL ,' (800) 632-4949 CALL 3 WORKING DAYS BEFORE YOU DIG! -p B+T GRP CITYS TCI-I NIOLIFITAlliii LTl • MOUNTAIN LTD, WIRELES U U z FA#10142260 E. z 0 V 0 C7 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 °° Kr-,4`/Fi IT IS A VIOLATION OF LAW ForANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. TITLE SHEET SHEET NUMBER: T-1 CASE # 20-08-GCCP-05794 E u9c N 0 E D 132151_NCC019_CD (11).dwg — Sheet:GN GENERAL NOTES 1. ALL REFERENCES MADE TO OWNER IN THESE DOCUMENTS SHALL BE CONSIDERED AT&T OR IT'S DESIGNATED REPRESENTATIVE. 2. ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST HAVE CONSIDERABLE EXPERIENCE IN PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBED HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS ATTESTING THAT HE DOES HAVE SUFFICIENT EXPERIENCE AND ABILITY, THAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED AND THAT HE IS PROPERLY LICENSED AND PROPERLY REGISTERED TO DO THIS WORK IN THE STATE OF NORTH CAROLINA. 3. THE STRUCTURE SHALL BE DESIGNED IN ACCORDANCE WITH ANSVTIA-222—G-2-2009. THIS CONFORMS TO THE REQUIREMENTS OF THE NORTH CAROLINA BUILDING CODE, 2012 EDITION. 4. WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE NORTH CAROLINA BUILDING CODE, 2012 EDITION. 5. UNLESS SHOWN OR NOTED OTHERWISE ON THE CONTRACT DRAWINGS, OR IN THE SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY TO THE MATERIALS LISTED HEREIN, AND TO THE PROCEDURES TO BE USED ON THIS PROJECT. 6. ALL HARDWARE ASSEMBLY MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED EXACTLY AND SHALL SUPERSEDE ANY CONFLICTING NOTES ENCLOSED HEREIN. 7. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE STRUCTURE AND IT'S COMPONENT PARTS DURING ERECTION AND/OR FIELD MODIFICATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF TEMPORARY BRACING, GUYS OR TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE PROJECT. 8. ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS SHOWN ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO BEGINNING ANY MATERIALS ORDERING, FABRICATION OR CONSTRUCTION WORK ON THIS PROJECT. CONTRACTOR SHALL NOT SCALE CONTRACT DRAWINGS IN LIEU OF FIELD VERIFICATION. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE OWNER'S ENGINEER. THE DISCREPANCIES MUST BE RESOLVED BEFORE THE CONTRACTOR IS TO PROCEED WITH THE WORK. THE CONTRACT DOCUMENTS DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY THE OWNER AND/OR THE ENGINEER SHALL NOT INCLUDE INSPECTION OF THE PROTECTIVE MEASURES OR THE PROCEDURES. 9. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY AND ALL SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT THIS PROJECT AND RELATED WORK COMPLIES WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. RENTAL CHARGES, SAFETY, PROTECTION AND MAINTENANCE OF RENTED EQUIPMENT SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 11. ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIALS ACCESS, WITH THE AT&T PROJECT MANAGER. 12. BILL OF MATERIALS AND PART NUMBERS LISTED ON CONSTRUCTION DRAWINGS ARE INTENDED TO AID CONTRACTOR/OWNER. CONTRACTOR/OWNER SHALL VERIFY PARTS AND QUANTITIES WITH MANUFACTURER PRIOR TO BIDDING AND/OR ORDERING MATERIALS. 13. ALL PERMITS THAT MUST BE OBTAINED ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR WILL BE RESPONSIBLE FOR ABIDING BY ALL CONDITIONS AND REQUIREMENTS OF THE PERMITS. 14. 24 HOURS PRIOR TO THE BEGINNING OF ANY CONSTRUCTION, THE CONTRACTOR MUST NOTIFY THE APPLICABLE JURISDICTIONAL (STATE, COUNTY OR CITY) ENGINEER. 15. THE CONTRACTOR SHALL REWORK (DRY. SCARIFY, ETC.) ALL MATERIAL NOT SUITABLE FOR SUBGRADE IN ITS PRESENT STATE. AFTER REWORKING, IF THE MATERIAL REMAINS UNSUITABLE, THE CONTRACTOR SHALL UNDERCUT THIS MATERIAL AND REPLACE WITH APPROVED MATERIAL. ALL SUBGRADES SHALL BE PROOFROLLED WITH A FULLY LOADED TANDEM AXLE DUMP TRUCK PRIOR TO PAVING. ANY SOFT MATERIAL SHALL BE REWORKED OR REPLACED. 16. THE CONTRACTOR IS REQUIRED TO MAINTAIN ALL PIPES, DITCHES, AND OTHER DRAINAGE STRUCTURES FREE FROM OBSTRUCTION UNTIL WORK IS ACCEPTED BY THE OWNER. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES CAUSED BY FAILURE TO MAINTAIN DRAINAGE STRUCTURE IN OPERABLE CONDITION. 17. THE OWNER SHALL HAVE A SET OF APPROVED PLANS AVAILABLE AT THE SITE AT ALL TIMES WHILE WORK IS BEING PERFORMED. A DESIGNATED RESPONSIBLE EMPLOYEE SHALL BE AVAILABLE FOR CONTACT BY GOVERNING AGENCY INSPECTORS. 18. ANY BUILDINGS ON THIS SITE ARE INTENDED TO SHELTER EQUIPMENT WHICH WILL ONLY BE PERIODICALLY MAINTAINED AND ARE NOT INTENDED FOR HUMAN OCCUPANCY. 19. TEMPORARY FACILITIES FOR PROTECTION OF TOOLS AND EQUIPMENT SHALL CONFORM TO LOCAL REGULATIONS AND SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 20. THE CONTRACTOR AND ITS SUBCONTRACTORS SHALL CARRY LIABILITY INSURANCE IN THE AMOUNTS AND FORM IN ACCORDANCE WITH AT&T SPECIFICATIONS. CERTIFICATES DEMONSTRATING PROOF OF COVERAGE SHALL BE PROVIDED TO AT&T PRIOR TO THE START OF THE WORK ON THE PROJECT. 21. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITY SERVICES TO VERIFY LOCATIONS OF EXISTING UTILITIES AND REQUIREMENTS FOR NEW UTILITY CONNECTIONS PRIOR TO EXCAVATING. 22. THE CONTRACTOR SHALL MAINTAIN THE JOB CLEAR OF TRASH AND DEBRIS. ALL WASTE MATERIALS SHALL BE REMOVED FROM THE SITE PRIOR TO SUBSTANTIAL COMPLETION AND PRIOR TO FINAL ACCEPTANCE. THE CONTRACTOR SHALL FURNISH ONE 55 GALLON BARREL, AND TRASH BAGS, AND SHALL REMOVE TRASH, DEBRIS, ETC., ON A DAILY BASIS. 23. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL CONDITIONS PRIOR TO SUBMITTING HIS PROPOSAL. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS WITH THOSE AT THE SITE. ANY VARIATION WHICH REQUIRES PHYSICAL CHANGE SHALL BE BROUGHT TO THE ATTENTION OF THE AT&T PROJECT ENGINEER FOR FACILITIES/CONSTRUCTION. 24. THE CONTRACTOR SHALL GUARANTEE THE WORK PERFORMED ON THE PROJECT BY THE CONTRACTOR AND ANY OR ALL OF THE SUBCONTRACTORS WHO PERFORMED WORK FOR THE CONTRACTOR ON THIS PROJECT. THE GUARANTEE SHALL BE FOR A FULL YEAR FOLLOWING ISSUANCE OF THE FINAL PAYMENT OF RETAINAGE. ALL MATERIALS AND WORKMANSHIP SHALL BE WARRANTED FOR ONE YEAR FROM ACCEPTANCE DATE. CALL NORTH CAROLINA ONE CALL(---`'rd q �► (800) 632-4949 CALL 3 WORKING DAYS L BEFORE YOU DIG! \� =IF B+T GRP C ITY� C H iht, > .OtitilTAIM LTD. MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 E. Z 0 V 0 C7 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 AAA vii...yTTT,,,, /100 **".0�/ A°1. , v.eS 10�1 .`�,0qs ` "fit s e SE Nej.eeul EL Ld/ R IS A VIOLATION OF LAW ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. GENERAL NOTES SHEET NUMBER: GN -1 CASE # 20-08-GCCP-05794 GPS NOTES THE FOLLOWING GPS STATISTICS UPON WHICH THIS SURVEY IS BASED HAVE BEEN PRODUCED AT THE 95% CONFIDENCE LEVEL: POSITIONAL ACCURACY: 0.04 FEET (HORZ) 0.14 FEET NERT) TYPE OF EQUIPMENT: GEOMAX ZENITH35 PRO BASE AND ROVER, DUAL FREQUENCY TYPE OF GPS FIELD PROCEDURE: ONLINE POSITION USER INTERFACE DATES OF SURVEY: 02/18/2019 DATUM / EPOCH: NAD_83(2011)(EPOCH:2010.0000) PUBLISHED / FIXED CONTROL USE: GEOID MODEL: 12B COMBINED GRID FACTOR(S): 0.99973616 CENTERED ON THE GPS BASE POINT AS SHOWN HEREON. CONVERGENCE ANGLE: 00°45'41.58" PARENT PARCEL OWNER: LAWRENCE B. MAY SITE ADDRESS: 4226 CAMP BURTON RD, MCLEANSVILLE, NC 27301 PARCEL ID: 115372 AREA: 7.46 ACRES (PER TAX ASSESSOR) ZONED: AG -AGRICULTURAL ALL ZONING INFORMATION SHOULD BE VERIFIED WITH THE PROPER ZONING OFFICIALS REFERENCE: DEED BOOK 2602 PAGE 384 LEGEND BS BOTTOM SLOPE C/L CENTERLINE EG EDGE OF GRAVEL EP EDGE OF PAVEMENT GW GUYWIRE IPF IRON PIN FOUND N/F NOW OR FORMERLY POB POINT OF BEGINNING POC POINT OF COMMENCEMENT R/W RIGHT OF WAY RCP REINFORCED CONCRETE PIPE RB REBAR SD SIGHT DISTANCE TBM TEMPORARY BENCHMARK TS TOP SLOPE UP UTILITY POLE IPF 3/8" RB N/F WILLIAM C. & ALICE E. FLYTHE PARCEL ID: 115364 ZONED: RS-30 DB 3486 PG 739 C/L 10' UTILITY EASEMENT SEE SHEET 2 FOR DETAIL S89'03'09'E 169.27' IPF 1 ROD N/F CAROLYN E. SMITH-KERR & FRED RICHARD KERR PARCEL ID: 115354 ZONED: RS-30 DB R 7908 PG 1068 N/F CHARLOTTE FOGLEMAN PARCEL ID: 115371 ZONED: AG -AGRICULTURAL DB R 6723 PG 30 C) r PROPERTY LINE N/F KERI EMORY WHITE PARCEL D: 115369 ZONED: RS-30 DB R 7850 PG 186 so. cPeU PfgOBRB\4 V FF�fV.� �243Z�0 '�2 --FP ipy PARENT PARCEL N/F LAWRENCE B. MAY PARCEL ID: 115372 ZONED: AG -AGRICULTURAL DB 2602 PG 384 N/F SHERRY E. CASEY/ PARCEL ID: 1153 ZONED: RS-30 DB 4907 PG 17 1 SEE SHEET 2 FOR DETAIL N/F DAVID W. & SHIRLEY TATUM PARCEL ID: 115373 ZONED: AG -AGRICULTURAL N/A PF 3/8' RB N/F THE CITY OF GREENSBORO PARCEL ID: 217968 ZONED: PI -UNKNOWN DB R 8059 PG 2437 SURVEYOR CERTIFICATION UP Pp tSITE KEELY RD VICINITY MAP NOT TO SCALE GENERAL NOTES * THIS SPECIFIC PURPOSE SURVEY IS FOR THE LEASED PREMISES AND EASEMENTS ONLY. THIS SPECIFIC PURPOSE SURVEY WAS PREPARED FOR THE EXCLUSIVE USE OF MOUNTAIN, LTD. & FIDELITY NATIONAL TITLE INSURANCE COMPANY, AND EXCLUSIVELY FOR THE TRANSFERRAL OF THE PROPOSED LEASED PREMISES AND THE RIGHTS OF EASEMENT SHOWN HEREON AND SHALL NOT BE USED AS AN EXHIBIT OR EVIDENCE IN THE FEE SIMPLE TRANSFERRAL OF THE PARENT PARCEL NOR ANY PORTION OR PORTIONS THEREOF. BOUNDARY INFORMATION SHOWN HEREON HAS BEEN COMPILED FROM TAX MAPS AND DEED DESCRIPTIONS ONLY. NO BOUNDARY SURVEY OF THE PARENT PARCEL WAS PERFORMED. THIS DRAWING DOES NOT REPRESENT A BOUNDARY SURVEY. THE FIELD DATA UPON WHICH THIS SPECIFIC PURPOSE SURVEY IS BASED HAS A CLOSURE PRECISION OF ONE FOOT IN 20,000+ FEET AND AN ANGULAR ERROR OF 5.0" PER ANGLE POINT AND WAS ADJUSTED USING LEAST SQUARES. EQUIPMENT USED FOR ANGULAR & LINEAR MEASUREMENTS: LEICA TPS 1200 ROBOTIC & GEOMAX ZENITH 35. [DATE OF LAST FIELD VISIT: 02/18/2019] THE 1' CONTOURS AND SPOT ELEVATIONS SHOWN ON THIS SPECIFIC PURPOSE SURVEY ARE ADJUSTED TO NAVD 88 DATUM (COMPUTED USING GEOID 12B) AND HAVE A VERTICAL ACCURACY OF t 0.5'. CONTOURS OUTSIDE THE IMMEDIATE SITE AREA ARE APPROXIMATE. BEARINGS SHOWN ON THIS SPECIFIC PURPOSE SURVEY ARE BASED ON NC GRID NORTH (NAD 83) NORTH CAROLINA ZONE. NO PORTION OF THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD AREA AS PER F.I.R.M. COMMUNITY PANEL NO. 3710789600J DATED 6/18/2007. NO WETLAND AREAS HAVE BEEN INVESTIGATED BY THIS SPECIFIC PURPOSE SURVEY. ALL ZONING INFORMATION SHOULD BE VERIFIED WITH THE PROPER ZONING OFFICIALS. ANY UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM ABOVE GROUND FIELD SURVEY INFORMATION. THE SURVEYOR MAKES NO GUARANTEES THAT ANY UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT ANY UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED ANY UNDERGROUND UTILITIES. I HEREBY CERTIFY THAT THIS NAP IS CORRECT AND WAS DRAWN UNDER MY DIRECT SUPERVISION. ANY VISIBLE ENCROACHMENTS ARE SHOWN HEREON. DATE: APRIL 20, 2020 G. DARRELL TAYLOR, NORTH CAROLINA PROFESS']L LAND SURVEYOR #L-3729 POINT TO POINT LAND SURVEYORS, INC. THIS MAP IS NOT A CERTIFIED SURVEY AND HAS NOT BEEN REVIEWED BY A LOCAL GOVERNMENT AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT REGULATIONS. THIS MAP IS ONLY INTENDED FOR THE PARTIES AND PURPOSES SHOWN. THIS MAP IS NOT FOR RECORDATION. 60 0 120 240 GRAPHIC SCALE IN FEET SCALE: 1" = 120' SURVEY NOT VALID WITHOUT SHEET 2 AND 3 NO. DATE REVISION 4 5 05/14/2020 02/08/2020 SITE NAME - DMM UTIL/LAND ESMT. -DMM 6 05/28/2021 LEASE AREA - DMM 7 6/2/2021 CLIENT COMMENTS SPECIFIC PURPOSE SURVEY PREPARED FOR: PrA MOUNTAIN, LTD. 1135 KILDAIRE FARM ROAD, SUITE 327 CARY, NC 27511 NCC019 JEFFERSON TOWNSHIP GUILFORD COUNTY, NORTH CAROLINA DRAWN BY: JHC CHECKED BY: JKL APPROVED: D. MILLER DATE: MARCH 18, 2019 P2P JOB #: 190666NC SHEET: 1 OF 3 E:'Dropbox (Point To PointN'2P Current Jobs \2019\190666NC-174173\190666NC.pro N/F CHARLOTTE FOGLEMAN PARCEL ID: 115371 ZONED: AG -AGRICULTURAL DB R 6723 PG 30 C/L 10' UTILITY EASEMENT RIGHTS TO BE ACQUIRED S3128'09'W 215.52' S76'02' 14' 130.00' N 13°57'46'E 130.00' S51 '43'22'E 65.08' S2325'301W 15.21' (TIE) LEGEND BS BOTTOM SLOPE C/L CENTERLINE EG EDGE OF GRAVEL EP EDGE OF PAVEMENT GW GUYWIRE IPF IRON PIN FOUND N/F NOW OR FORMERLY POB POINT OF BEGINNING POC POINT OF COMMENCEMENT R/W RIGHT OF WAY RCP REINFORCED CONCRETE PIPE RB REBAR SD SIGHT DISTANCE TBM TEMPORARY BENCHMARK TS TOP SLOPE UP UTILITY POLE ti� TS �I O� c1Dc BS S7L co TS 725j / 727 =' 7281 ,2g � 00 N >�1 \, N `> \\ �2 N s \ s \ \\>�> LEASE AREA RIGHTS TO BE ACQUIRED TS BS TS S>>e"'! S12¢sr�E 138 _ 131 .336 —735 133 7731- ZNSINA 6 \ \ \\\\: \\\\\1:\\ POB: LEASE_--\ \\ \ TBM ELEV: 738.9' 13°57'46V 130.00' \ \ j \ \ y Ts, Q s3 �>� sN76°02'14"W Qw✓ 9 130.00' B• 6gMp 4Q R/WPERD�U" , 7. .„0,. ` \ R 8059Ip V 41'4) S29° 13'40'W 544.60' GPS BASE C/L 25' ACCESS EASEMENT RIGHTS TO BE ACQUIRED PARENT PARCEL N/F LAWRENCE B. MAY PARCEL ID: 115372 ZONED: AG -AGRICULTURAL DB 2602 PG 384 50 0 N/F DAVID W. & SHIRLEY TATUM PARCEL ID: 115373 ZONED: AG -AGRICULTURAL N/A SITE INFORMATION LEASE AREA = 16,900 SQUARE FEET (0.3880 ACRES) LATITUDE = 36°06'50.39" (NAD 83) (36.113997°) LONGITUDE = -79°42'32.86" (NAD 83) (79.709128°) AT CENTER OF LEASE AREA ELEVATION AT CENTER OF LEASE AREA = 747.1' A.M.S.L. IPF 3/5 RB TITLE EXCEPTIONS THIS SURVEY WAS COMPLETED WITH THE AID OF TITLE WORK PREPARED BY FIDELITY NATIONAL TITLE INSURANCE COMPANY, COMMITMENT DATE OF MARCH 6, 2020, BEING COMMITMENT NO. 31037499, FOR THE PARENT PARCEL, TO DETERMINE THE IMPACTS OF EXISTING TITLE EXCEPTIONS. SCHEDULE B, PART II 8. DEED OF TRUST FROM LAWRENCE B. MAY, GRANTOR(S), TO PHILIP E. GREER, TRUSTEE(S), IN FAVOR OF STATE EMPLOYEES' CREDIT UNION, DATED OCTOBER 9, 2003, AND RECORDED NOVEMBER 25, 2003 IN DEED BOOK 5989, PAGE 2881, IN THE ORIGINAL AMOUNT OF $99,000.00. [THIS ITEM IS APPLICABLE TO THE PARENT PARCEL, LEASE AREA AND ACCESS EASEMENT AND CONTAINS NO ADDITIONAL, PLOTTABLE ITEMS] 9. NOTICE OF PARTICIPATION IN VOLUNTARY AGRICULTURAL DISTRICT, DATED JANUARY 12, 2006 AND RECORDED JANUARY 20, 2006 IN DEED BOOK 6469, PAGE 1771. [THIS ITEM IS APPLICABLE TO THE PARENT PARCEL BUT IS NOT PLOTTED HEREON BECAUSE IT IS BLANKET IN NATURE] 100 200 GRAPHIC SCALE IN FEET SCALE: 1" = 100' NO. DATE REVISION 4 5 05/14/2020 02/08/2020 SITE NAME - DMM UTIL/LAND ESMT. -DMM 6 05/28/2021 LEASE AREA - DMM 7 6/2/2021 CLIENT COMMENTS SPECIFIC PURPOSE SURVEY PREPARED FOR: MOUNTAIN, LTD. 1135 KILDAIRE FARM ROAD, SUITE 327 CARY, NC 27511 NCC019 JEFFERSON TOWNSHIP GUILFORD COUNTY, NORTH CAROLINA SURVEY NOT VALID WITHOUT SHEET 1 AND 3 DRAWN BY: JHC CHECKED BY: JKL APPROVED: D. MILLER DATE: MARCH 18, 2019 P2P JOB #: 190666NC SHEET: 2 OF 3 E:'Dropbox (Point To Point)T2P Current Jobs\2019\190666NC-174173\190666NC.pro LEGAL DESCRIPTION SHEET PARENT PARCEL (PER FIDELITY NATIONAL TITLE INSURANCE COMPANY COMMITMENT NO. 31037499) AN INTEREST IN LAND, SAID INTEREST BEING OVER A PORTION OF THE FOLLOWING DESCRIBED PARENT PARCEL: THAT CERTAIN TRACT OR PARCEL OF LAND LYING AND BEING IN JEFFERSON TOWNSHIP, GUILFORD COUNTY, NORTH CAROLINA, DESCRIBED AS FOLLOWS: BEGINNING AT A STAKE IN THE SOUTHERN MARGIN OF N. C. STATE ROAD # 2825, (PRISON CAMP ROAD), IN E. A. GOODWIN'S WEST LINE; RUNNING THENCE WITH GOODWIN'S WEST LINE SOUTH 29° 00' 20" WEST 446.75 FEET TO AN EXISTING IRON PIN, GOODWIN'S SOUTHWEST CORNER AND C. A. KEELY'S NORTHWEST CORNER; THENCE WITH KEELY'S WEST LINE SOUTH 32° 28' 55" WEST 576.11 FEET TO AN EXISTING IRON PIN, C. S. KEELY'S NORTHEAST CORNER; THENCE ALONG C. S. KEELY'S LINE, NORTH 86° 54' 10" WEST 185.23 FEET; THENCE ALONG KINLEY'S AND L.A. SAMPSON'S LINE NORTH 87° 10' 47" WEST 169.31 FEET TO AN EXISTING IRON; THENCE A NEW DIVISION LINE NORTH 32° 30' 26" EAST 1125.93 FEET TO A NEW IRON PIN IN THE SOUTHERN MARGIN OF STATE ROAD #2825; THENCE ALONG THE SOUTHERN MARGIN OF SAID ROAD SOUTH 69° 48' 55" EAST 190.0 FEET AND SOUTH 75° 09' 55" EAST 100.00 FEET TO THE POINT OF BEGINNING, CONTAINING 7.461 ACRES, MORE OR LESS, AS PER PLOT THEREOF PREPARED BY ROBERT E. WILSON, INC., LAND SURVEYOR, DATED DECEMBER 9, 1971. AND BEING THE SAME PROPERTY CONVEYED TO LAWRENCE B. MAY FROM FRED P. COOK AND BESSIE COOK BY DEED DATED AUGUST 11, 1972 AND RECORDED AUGUST 22, 1972 IN DEED BOOK 2602, PAGE 384; AND FURTHER CONVEYED TO JESSE MAY, LLC, (A NORTH CAROLINA LIMITED LIABILITY COMPANY) FROM LAWRENCE B. MAY BY NORTH CAROLINA GENERAL WARRANTY DEED DATED AUGUST 21, 2019 AND RECORDED SEPTEMBER 6, 2019 IN DEED BOOK 8192, PAGE 1903. TAX PARCEL NO. 115372 25' ACCESS EASEMENT TOGETHER WITH A 25-FOOT WIDE ACCESS EASEMENT (LYING 12.5 FEET EACH SIDE OF CENTERLINE), LYING AND BEING IN JEFFERSON TOWNSHIP, GUILFORD COUNTY, NORTH CAROLINA, AND BEING A PORTION OF THE LANDS CONVEYED TO LAWRENCE B. MAY, AS RECORDED IN DEED BOOK 2602, PAGE 384, AND BEING DESCRIBED BY THE FOLLOWING CENTERLINE DATA: TO FIND THE POINT OF BEGINNING, COMMENCE AT A 3/8-INCH REBAR FOUND ON THE NORTHWEST CORNER OF AFORESAID CONVEYANCE, AND ON THE SOUTH RIGHT-OF-WAY LINE OF CAMP BURTON ROAD (HAVING A 60-FOOT PUBLIC RIGHT-OF-WAY), SAID REBAR HAVING A NORTH CAROLINA GRID NORTH, NAD83, VALUE OF N=861889.7932, E=1790847.7425, THENCE RUNNING ALONG SAID RIGHT-OF-WAY LINE, SOUTH 71°54'47" EAST, 25.95 FEET TO A POINT, SAID POINT HAVING A NORTH CAROLINA GRID NORTH, NAD83, VALUE OF N=861881.7362, E=1790872.4121 AND THE TRUE POINT OF BEGINNING; THENCE LEAVING SAID RIGHT-OF-WAY LINE AND RUNNING, SOUTH 29°13'40" WEST, 544.60 FEET TO A POINT; THENCE, SOUTH 31°28' 09" WEST, 215.52 FEET TO A POINT; THENCE, SOUTH 13°57'46" WEST, 115.00 FEET TO THE ENDING AT A POINT. BEARINGS ARE BASED ON A NORTH CAROLINA GRID NORTH, NAD83. LEASE AREA ALL THAT TRACT OR PARCEL OF LAND LYING AND BEING IN JEFFERSON TOWNSHIP, GUILFORD COUNTY, NORTH CAROLINA, AND BEING A PORTION OF THE LANDS CONVEYED TO LAWRENCE B. MAY, AS RECORDED IN DEED BOOK 2602, PAGE 384, AND BEING DESCRIBED AS FOLLOWS: TO FIND THE POINT OF BEGINNING, COMMENCE AT A 3/8-INCH REBAR FOUND ON THE NORTHWEST CORNER OF AFORESAID CONVEYANCE, AND ON THE SOUTH RIGHT-OF-WAY LINE OF CAMP BURTON ROAD (HAVING A 60-FOOT PUBLIC RIGHT-OF-WAY), SAID REBAR HAVING A NORTH CAROLINA GRID NORTH, NAD83, VALUE OF N=861889.7932, E=1790847.7425, THENCE RUNNING ALONG SAID RIGHT-OF-WAY LINE, SOUTH 71°54'47" EAST, 25.95 FEET TO A POINT, SAID POINT HAVING A NORTH CAROLINA GRID NORTH, NAD83, VALUE OF N=861881.7362, E=1790872.4121; THENCE LEAVING SAID RIGHT-OF-WAY LINE AND RUNNING, SOUTH 29°13'40" WEST, 544.60 FEET TO A POINT; THENCE, SOUTH 31°28'09" WEST, 215.52 FEET TO A POINT; THENCE, SOUTH 13°57'46" WEST, 115.00 FEET TO A POINT; THENCE, SOUTH 23°25'30" WEST, 15.21 FEET TO A POINT AND THE TRUE POINT OF BEGINNING; THENCE RUNNING, NORTH 13°57'46" EAST, 130.00 FEET TO A POINT; THENCE, SOUTH 76°02'14" EAST, 130.00 FEET TO A POINT; THENCE, SOUTH 13°57'46" WEST, 130.00 FEET TO A POINT; THENCE, NORTH 76°02'14" WEST, 130.00 FEET TO A POINT AND THE POINT OF BEGINNING. BEARINGS ARE BASED ON A NORTH CAROLINA GRID NORTH, NAD83. SAID TRACT CONTAINS 0.3880 ACRES (16,900 SQUARE FEET), MORE OR LESS. 10' UTILITY EASEMENT TOGETHER WITH A 10-FOOT WIDE ACCESS EASEMENT (LYING 5 FEET EACH SIDE OF CENTERLINE), LYING AND BEING IN JEFFERSON TOWNSHIP, GUILFORD COUNTY, NORTH CAROLINA, AND BEING A PORTION OF THE LANDS CONVEYED TO LAWRENCE B. MAY, AS RECORDED IN DEED BOOK 2602, PAGE 384, AND BEING DESCRIBED BY THE FOLLOWING CENTERLINE DATA: TO FIND THE POINT OF BEGINNING, COMMENCE AT A 3/8-INCH REBAR FOUND ON THE NORTHWEST CORNER OF AFORESAID CONVEYANCE, AND ON THE SOUTH RIGHT-OF-WAY LINE OF CAMP BURTON ROAD (HAVING A 60-FOOT PUBLIC RIGHT-OF-WAY), SAID REBAR HAVING A NORTH CAROLINA GRID NORTH, NAD83, VALUE OF N=861889.7932, E=1790847.7425, THENCE RUNNING ALONG SAID RIGHT-OF-WAY LINE, SOUTH 71°54'47" EAST, 5.12 FEET TO A POINT, SAID POINT HAVING A NORTH CAROLINA GRID NORTH, NAD83, VALUE OF N=861888.2039, E=1790852.6087 AND THE TRUE POINT OF BEGINNING; THENCE LEAVING SAID RIGHT-OF-WAY LINE AND RUNNING, SOUTH 30°28'23" WEST, 824.27 FEET TO A POINT; THENCE, SOUTH 51°43'22" EAST, 65.08 FEET TO AN ENDING POINT ON THE LEASE AREA. BEARINGS ARE BASED ON A NORTH CAROLINA GRID NORTH, NAD83. NO. DATE REVISION 4 5 05/14/2020 02/08/2020 SITE NAME - DMM UTIL/LAND ESMT. -DMM 6 05/28/2021 LEASE AREA - DMM 7 6/2/2021 CLIENT COMMENTS SPECIFIC PURPOSE SURVEY PREPARED FOR: fin MOUNTAIN, LTD_ 1135 KILDAIRE FARM ROAD, SUITE 327 CARY, NC 27511 NCC019 JEFFERSON TOWNSHIP GUILFORD COUNTY, NORTH CAROLINA [SURVEY NOT VALID WITHOUT SHEES 1 AND 2 DRAWN BY: JHC CHECKED BY: JKL APPROVED: D. MILLER DATE: MARCH 18, 2019 P2P JOB #: 190666NC SHEET: OF 3 E:\Drophox (Point To Point)\P2P Current Jobs \2019\190666NC-174-173\190666NC.pro User: mspeedie dwg — Sheet:C 132151_NCC019_CD N/F CHARLOTTE FOGLEMAN PARCEL ID: 115371 ZONED: AG —AGRICULTURAL DB R 6723 PG 30 SITE GEOMETRY: LINE L1 L2 L3 L4 L5 L6 L7 BEARING S29°13'40"W S31°28'93"W S13°57'46"W S76°02' 14"E S13°57'46"W N76°02' 14"W N 13°57'46"E DISTANCE (FT) 544.60 215.52 115.00 130.00 130.00 130.00 130.00 PROPOSED 50' x 50' FENCED GRAVEL COMPOUND L3 PROPOSED 130' x 130' LEASE PARCEL N/F WILLIAM C. & ALICE E. FLYTHE PARCEL ID: 115364 ZONED: RS-30 DB 3486 PG 739 CARC & F PA DB WETLAND LIMITS EXISTING 12" RCP L6 PARENT TRACT N/F LYN E. SMITH— ERR RED RICHARD K RR RCEL ID: 11535 ZONED: RS-30 R 7908 PG 10 8 L2 +I co N EXISTING RCP PROPOSED 10' WIDE UTILITY EASEMENT PROPOSED 14' WIDE GRAVEL ACCESS ROAD N/F KERI EMORY WHITE PARCEL ID: 115369 ZONED: RS-30 DB R 7850 PG 186 N/F SHERRY E. CASEY PARCEL ID: 115356 ZONED: RS-30 DB 4907 PG 1711 PAR Air cry T pAp PROPOSED 25' WIDE INGRESS/EGRESS EASEMENT PARENT PARCEL N/F LAWRENCE B. MAY PARCEL ID: 115372 ZONED: AG —AGRICULTURAL DB 2602 PC 384 EXIST. STREAM N/F DAVID W. & SHIRLEY TATUM PARCEL ID: 115373 ZONED.: AG —AGRICULTURAL N/A N/F THE CITY OF GREEN•SBORO PARCEL ID: 217968 ZONED: PI —UNKNOWN DB R 8059 PG 2437 0 OVERALL SITE PLAN SCALE: 0' NOTES: CENTER OF TOWER: LATITUDE: NORTH 36°06'50.39" (36.113997) NAD 83 LONGITUDE: WEST-79°42'32.86" (-79.709128) NAD 83 GROUND ELEVATION @ 747.1' A.M.S.L. 1. THE PERPENDICULAR DISTANCES FROM THE CENTER OF PROPOSED TOWER TO PARENT TRACT BOUNDARY LINE WERE ESTABLISHED FROM ACTUAL FIELD MEASUREMENTS AND OBSERVATIONS PERFORMED BY POINT TO POINT LAND SURVEYORS 2/18/2019. AND ARE AS FOLLOWS: NORTH: SOUTH: EAST: WEST: 804.3'± 228.6'± 197.4'± 111.8'± 2. EXISTING FEATURES SHOWN ARE BASED ON FIELD SURVEY BY POINT TO POINT LAND SURVEYORS PERFORMED ON 2/18/2019. REFER TO THIS SURVEY FOR ADDITIONAL BOUNDARY INFORMATION. FLOOD ZONE NOTE: NO PORTION OF THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD AREA AS PER F.I.R.M. COMMUNITY PANEL NO. 3710789600J DATED 6/18/2007. 60' 120' 180' 1"=120' 240' CALL NORTH CAROLINA ONE CALL �( (800) 632-4949 CALL 3 WORKING DAYS BEFORE YOU DIG! =IF B+T GRP C ITYS TCI—! MOUNTAIN ISM MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 z O V 0 17-1 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 eeb � nr15/�1 eeN 7 u .6 IT IS A 1OtATION OF LAW ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. OVERALL PARCEL PLAN SHEET NUMBER: c-o CASE # 20-08-GCCP-05794 132151_NCC019_CD DRAINAGE NARRATIVE: THE PROPOSED SITE DISTURBANCE FOR THIS CELL TOWER SITE INCLUDES A 808' ONSITE ACCESS ROAD AND TURNAROUND, A 50'X50' NON —VEHICULAR GRAVEL COMPOUND, AND THE LANDSCAPE AREA SURROUNDING THE 50' X 50' GRAVEL COMPOUND. THE TOTAL PROPOSED DISTURBED AREA IS 40,487.52 SF (0.929 AC). THE TOTAL PROPOSED DISTURBANCE AREA IS LESS THAN 1 ACRE. A GRADING PERMIT IS NOT REQUIRED. THIS AREA IS CURRENTLY UNDEVELOPED. THE PRE —DEVELOPMENT FLOW RATE IS BASED ON THE RATIONAL METHOD (Q=CiA), C=0.35, i=0.304 IN/HR, A=7.47 AC FOR A 100—YR 24—HR DESIGN STORM PER NOAA ATLAS 14 POINT PRECIPITATION DATA. THE POST —DEVELOPMENT FLOW RATE IS CALCULATED USING THE RATIONAL METHOD WITH A WEIGHTED 'C' VALUE OF 0.38. THE PRE —DEVELOPMENT IMPERVIOUS COVER HAS BEEN TREATED AS 0 SF AND THE POST DEVELOPMENT IMPERVIOUS COVER IS 16,455.34 SF. THE PARENT PARCEL IS 325,257.31 SF. THE PROPOSED POST DEVELOPMENT IMPERVIOUS COVER IS 5.1% Qpre = 0.795 CFS Qpost = 0.863 CFS THE PROPOSED DEVELOPMENT WILL RESULT IN AN INCREASE IN STORMWATER RUNOFF OF 0.068 CFS. WATERSHED INFORMATION: NORTH BUFFALO CREEK THE NORTH BUFFALO CREEK SUBWATERSHED (HUC12: 030300020105) IS IN THE REEDY FORK WATERSHED (HUC10:0303000201) WITHIN THE HAW RIVER SUBBASIN (HUC8: 030300002) WHICH IS A PART OF THE CAPE FEAR RIVER BASIN (HUC6: 030300). NOTE: ACCESS DRIVE SHALL CONSIST OF AN "ALL- WEATHER" GRAVEL SURFACE. PROPOSED 10' WIDE UTILITY EASEMENT N/F CHARLOTTE FOGLEMAN PARCEL ID: 115371 ZONED: AG —AGRICULTURAL DB R 6723 PC 30 WETLAND LIMITS EXISTING 12" RCP EXISTING TREE LINE L2 PROPOSED 130' x 130' LEASE PARCEL PROPOSED 50' x 50' FENCED GRAVEL COMPOUND PROPOSED PARKING AND TURNAROUND AREA SITE GEOMETRY: LINE L1 L2 L3 L4 L5 L6 L7 BEARING S29°13'40"W S31°28'93"W S13°57'46"W S76°02' 14"E S13°57'46"W N76°02' 14"W N13°57'46"E DISTANCE (FT) 544.60 215.52 115.00 130.00 130.00 130.00 130.00 L3 L7 L6 PARENT TRACT OVERALL SITE PLAN SCALE: 0' Culp 8, itoiv 6°' EAD EXISTING RCP EXISTING OVERHEAD POWER N/F DAVID W. & SHIRLEY TATUM PARCEL ID: 115373 ZONED: AG —AGRICULTURAL N/A PROPOSED 14' WIDE GRAVEL ACCESS ROAD PROPOSED 25' WIDE INGRESS/EGRESS EASEMENT PARENT PARCEL N/F LAWRENCE B. MAY PARCEL ID: 115372 ZONED: AG —AGRICULTURAL DB 2602 PG 384 WETLAND LIMITS PROPOSED AT&T 240 SQ FT LEASE AREA _PROPOSED 220' SELF SUPPORT TOWER 50' 100' 150' N/F SHERRY E. CASEY PARCEL ID: 115356 ZONED: RS-30 DB 4907 PG 1711 1 "=100' 200' N/F THE CITY OF GREENSBORO PARCEL ID: 217968 ZONED: PI —UNKNOWN DB R 8059 PG 2437 EXIST. STREAM WETLAND TABLE: STREAM LENGTH = 390' (PERENNIAL, WITHIN PARCEL) STREAM WIDTH = 3' +/- LENGTH OF STREAM IMPACTS 40' (CULVERT) NOTES: 1. SEE LEGEND, SITE DATA, AND GENERAL NOTES ON SHEETS GN-1. 2. TOWER LATITUDE, LONGITUDE & ELEVATION MEET FAA"1-A" ACCURACY REQUIREMENTS. 3. PROPOSED SELF-SUPPORT TOWER. CENTER OF TOWER: LATITUDE: NORTH 36°06'50.39" (36.113997) NAD 83 LONGITUDE: WEST-79°42'32.86" (-79.709128) NAD 83 GROUND ELEVATION @ 747.1' A.M.S.L. 4. THE PERPENDICULAR DISTANCES FROM THE CENTER OF PROPOSED TOWER TO PARENT TRACT BOUNDARY LINE WERE ESTABLISHED FROM ACTUAL FIELD MEASUREMENTS AND OBSERVATIONS PERFORMED BY POINT TO POINT LAND SURVEYORS 2/18/2019. AND ARE AS FOLLOWS: NORTH: SOUTH: EAST: WEST: 804.3'± 228.6'± 197.4'± 111.8'± 5. EXISTING FEATURES SHOWN ARE BASED ON FIELD SURVEY BY POINT TO POINT LAND SURVEYORS PERFORMED ON 2/18/2019. 6. THIS PLAN IS NOT A BOUNDARY SURVEY. PROPERTY BOUNDARY INFORMATION SHOWN IS FOR REFERENCE ONLY. POINT TO POINT LAND SURVEYORS DID NOT VERIFY BOUNDARY AS PART OF THIS SURVEY. DEED BEARING AND DISTANCE IN PARENTHESIS. 7. NO WETLANDS INVESTIGATION WAS PERFORMED AS PART OF THIS SURVEY. 8. NO INVESTIGATION OF THE PRESENCE OF HAZARDOUS MATERIALS WAS PERFORMED AS A PART OF THIS SURVEY. 9. UTILITIES SHOWN PER FIELD LOCATIONS FROM ABOVE GROUND INSPECTION OF THE SITE AND UTILITY MARK -OUTS IN THE FIELD. UTILITIES THAT EXIST MAY NOT BE SHOWN. 10. CONTRACTOR TO VERIFY POWER & TELCO DEMARCS WITH UTILITY PROVIDERS PRIOR TO BIDDING PROJECT. 11. NO WATER, WASTEWATER, OR SEPTIC UTILITIES ARE REQUIRED FOR THIS DEVELOPMENT. 12. THE TOWER SHALL BE DESIGNED TO SUPPORT AT LEAST 6 ANTENNA ARRAYS. FLOOD ZONE NOTE: NO PORTION OF THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD AREA AS PER F.I.R.M. COMMUNITY PANEL NO. 3710789600J DATED 6/18/2007. CALL NORTH CAROLINA ONE CALL skl L-_; (800) 632-4949 CALL 3 WORKING DAYS BEFORE YOU DIG! =IF B+T GRP C ITYSWITCH NIOUNTAINi LTD. MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 E. Z O PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 © t GP/ - % 'r l' 4�,�� rs K�,4`i/Fi 1. IT IS A MOLAnON OF LAW FOrANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. OVERALL SITE PLAN SHEET NUMBER: c-1 CASE # 20-08-GCCP-05794 N U 0 E 132151_NCC019_CD (11).dwg — Sheet:C-2.1 — PROPOSED 275 LF± 14' WIDE GRAVEL ACCESS ROAD PROP. 10' UTILITY EASEMENT FG=744.7 FG=745.2 FG= 47 1 FG=747.6 \ / 12' DOUBLE SWING GATE FG=749.0 FG=748.4 FG=748.6 FG=749.0 PROPOSED H-FRAME PROPOSED 220' SELF SUPPORT TOWER. PROPOSED 50' x 50' FENCED COMPOUND \ \ . PROPOSED 130' x 130' \� LEASE AREA 11 it LA N ll MAT CHINE A (807TO RIGH7) / N \ PROPOSED 25 WIDE \ INGRESS/EGRESS • EASEMENT PROP. UNDERGROUND ELEC. PROP. UNDERGROUND TELCO 4E PROPOSED AT&T 240 SQ. FT. LEASE AREA TOC=747.48 A FG=742.4 \ 0 NOTES: ACCESS DRIVE SHALL CONSIST OF AN "ALL- WEATHER" GRAVEL SURFACE. REFER TO SHEET E-2 FOR CARRIER GROUND EQUIPMENT INFORMATION. LEGEND FG=745.9 INDICATES EXISTING CONTOUR INDICATES FINISHED GRADE ELEVATION WETLAND LIMITS PROPOSED SILT FENCE (TYP) TOTAL 230 LF± WETLAND LIMITS THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING ON THE WORK CONTAINED WITHIN THIS DESIGN PACKAGE. DISCREPANCIES AND OMISSIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. M4»'c S1'/T y41/yF PROP. 10' UTILITY EASEMENT / // PROPOSED 380 LF± 14' WIDE GRAVEL ACCESS ROAD PROP. UNDERGROUND E-1 ELEC. O PROP. UNDERGROUND TELCO REMOVE 26' EXISTING 12" RCP 411 TEMPORARY OUTLET NIF PROTECTION PROPOSED IMPROVEMENTS PLAN SCALE: 0' o//////////// ////////////////// 20' 40' 60' 1"=40' 80' MATCH (Tpp LEFT) A 4/ / / / 733 / 731 / PROPOSED 25' WIDE INGRESS/EGRESS / EASEMENT / / / INSTALL TEMPORARY 9. ii ;) INLET PROTECTION INSTALL 40 L.F. 18" ADS N-12 S.D. PIPE WITH END SECTIONS (OR APPROVED EQUAL) (SEE DETAILS 1, 2 SHEET C-9.3) FG=726.3 WETLAND LIMITS CALL NORTH CAROLINA ONE CALL( (800) 632-4949� CALL 3 WORKING DAYS L BEFORE YOU DIG! B+T GRP C ITYSWITCH MOUNTAIN,, LTD. MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 Z 0 V 0 C7 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 a�0 ft QQ SE s� �' IT IS A VIOLATION OF LAW FOdANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. PROPOSED IMPROVEMENTS PLAN SHEET NUMBER: C-2.1 CASE # 20-08-GCCP-05794 NOTE: ACCESS DRIVE SHALL CONSIST OF AN "ALL- WEATHER" GRAVEL SURFACE. LEGEND 4/-1 FG=745.9 INDICATES EXISTING CONTOUR INDICATES FINISHED GRADE ELEVATION PROPOSED ELEC & TELCO DEMARC EXISTING OVERHEAD POWER PROP. 10' UTILITY EASEMENT PROPOSED 205 LF± 14' WIDE GRAVEL ACCESS ROAD OPROP. UNDERGROUND E-1 ELEC. OPROP. UNDERGROUND E-1 TELCO 47,4 Stir 'Z1ti car ,/ / / / / / / / / / / THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING ON THE WORK CONTAINED WITHIN THIS DESIGN PACKAGE. DISCREPANCIES AND OMISSIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. / /l /1 / / / / 0 / / / MATCH EX. FG=735.8± / / 1- / EXISTING 8" RCP MATCH EX. FG=735.9± / PROPOSED HANDHOLE PROPOSED 25' WIDE ACCESS & UTILITY EASEMENT PROPOSED IMPROVEMENTS PLAN SCALE: 0' 20' 40' 60' 1"=40' 80' CALL NORTH CAROLINA ONE CALL �C (800) 632-4949 CALL 3 WORKING DAYS BEFORE YOU DIG! B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 Z O V Q C7 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 • (y- SEL R IS A MOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PROPOSED IMPROVEMENTS PLAN SHEET NUMBER: C-2.2 CASE # 20-08-GCCP-05794 dwg — Sheet:C 132151_NCC019_CD PROPOSED 10' WIDE UTILITIES EASEMENT PROPOSED 197 LF± 14' WIDE GRAVEL ACCESS ROAD SWING GATE / / / / / L / / / / / / / / / / / / / PROPOSED 25' WIDE INGRESS/EGRESS EASEMENT PROPOSED PLATFORM/ / CONCRETE PAD / PROPOSED 130' x 130' LEASE AREA COMPOUND DIMENSION PLAN SCALE: 0' 10' 20' 30' 1 "=20' 40' PROPOSED AT&T 240 SQ. FT. LEASE AREA 40, THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING ON THE WORK CONTAINED WITHIN THIS DESIGN PACKAGE. DISCREPANCIES AND OMISSIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. CALL NORTH CAROLINA ONE CALL (800) 632-4949ll CALL 3 WORKING DAYS BEFORE YOU DIG! =IF B+T GRP CITYS TCI-I NIOUNTAINi LTD. MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 Z O V PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 CA f,, tify SE 4 r7 K`++� FOR ANY PERSON UNLESS IT ISAVIOLATIVIOLATION OF LAW THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. COMPOUND DIMENSION PLAN SHEET NUMBER: C-2.3 CASE # 20-08-GCCP-05794 User: mspeedie dwg — Sheet:C 132151_NCC019_CD . . 1 I D i'•' " ri c c, O 0..O 7'-0' 0 REAR ELEVATION SCALE: N.T.S. 0 0 . n1 inuesu n11pg4 RIGHT ELEVATION SCALE: N.T.S. • 0 o o }n1:uo:m:LnLn::n::{ o b 0 6'-8" LEFT ELEVATION 3/C-3 SCALE: N.T.S. Oil 0 • • • FRONT ELEVATION SCALE: N.T.S. 1/C-3 4/C-3 GENERAL STRUCTURAL NOTES: 1. CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE ACI CODE. SEE SHT C-9.1 FOR CONCRETE PAD DETAILS. 2. REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH THE CONCRETE REINFORCING STEEL INSTITUTE (CRSI) -MANUAL OF STANDARD PRACTICE... 3. DESIGN SHALL BE PER LOCAL AND STATE BUILDING CODES. WHITE/BLUE BACKGROUND W/ BLACK LETTERING QUANTITY: (1) SIZE: 9'x12' (TO BE MOUNTED ON EQUIPMENT SHELTER DOOR OR DOOR SIDE EXTERIOR WALL ADJACENT TO COMPOUND ENTRY — SEE NOTE 3) SITE IDENTIFICATION SIGN 11 "x17 SCALE: NTS 24"x36" SCALTE: NTS 2/C-3 =IF B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES C U U z FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 0 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 r111...rier fit.. i ‘,iES Ip�ti r er, IT IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. WALK-IN CABINET DETAILS SHEET NUMBER: C-3 CASE # 20-08-GCCP-05794 4. — Sheet:G _i1_NCC019_CD SDC20 I 2.5L 20 kW - AC INDUSTRIAL DIESEL GENERATOR SET EPA Carolled Stationary Emergency Shoddy Power R8INq 20 MAC. 60 Hs Codes and Standards Generic producl* ere desired M Pe folios/mg standards: wrarr UL2200, UL508, UL142, U1489 LMJ NFPA 37. 70. 99, 110 ONEC700. 701. 702, 708 w T1IP{o ISO 3048, 7637, 8528, 9001 11111911111011 NEMA ICSIO. MG1. 250. ICS6. A81 -_ _ _ ANSI C62,41 SDC20 2.5L I 20 kW - AC INDUSTRIAL DIESEL GENERATOR SET EPA Cerolied 5(a50nary Emergency OPERATING DATA OENERAC INDUSTRIAL Model G007098.0 ISIeeh Powering Ahead For over 50 years. Generic has provided Innovative design and 50p0102 manufactured Generic ensures supenor Wally by designing and manufacturing most 0f its generator C01npOnenl$. including rtemat0rs, enclosure( and base I9Ak5, e00e0) Sy5te61s and CIXnm09Gai10n5 software General gensets utaea a wale v046(13 Of ODOODnM. e011119N900ns and arrangements, allowing us to meet the standby power needs of practically every application. Generic searched globally to ensure the most reliable engnes power our generators. We choose only engines that have already been proven in heari-duly adu5u9i 3pp1ic8e7ns under adverse c0ncenons. Genera[ is C60m8[ed 10 ensuing Our 61$-foes' sem0e support continues alter der generator purchase POWER RATINGS 525648948 120240 VAC 401 Op 20459 CrM Bear sat 1001 GENERAC INDusTRIAL Mode( 0007098-0 15Iee1) FUEL CONSUMPTION PATES' DeeSel - 9M pVg Perna Ld9 Stray 25, 50% 0N(2M) 099 4315) 756 1411530) 1016% 100 (218) • RP81064 W>°erm 6940 wean mMef a 0010002000163r 1995Ian COOLING C0000100 0e TAM! Cewn SW.) 40600e Hem 00104 *m Cairn Weed W. 54,4.6 Nroem 1244300 a I11el0e044284) w..,.,, AOM00 aamressu. Sammy 119145) 351132) 238200 2365(671 TP 1251 DM COMBUSTION MR REQUIREMENTS Fmv 4 PAP Pinner din I00601 081219) 6426 E8020 Speed 12080(0v.0 n R*M LW-• Rag span Nee Starry lam 335 122047 96.5 EXHAUST Lem.1Nw IRaeo Ovop Mai 9Y1Fressue (Pos15Mntlq E2.2201 temp (9*e Gu91A-Post SWAPO m 11.5.5arsneerwry:neemlts.kr2P.masr.4429m 6040264 de (040n1 rep Ph) sin 54 ale 19302a1 1181167) 92914977) dram-gpe0matwacbmsbmcanPwr man..,ano,.4cwMos paelawsmp4EAMubgypealPomama Pesewmun a Gemm Pere5yslem waste 0wlwtr a9Bd,W MUM Mtrlm emer69tw* ANts.IA407W6, 90514. moans -mg 0016271 Mmdadi SDC20 N 2.5L I 20 kW - AC INDUSTRIAL DIESEL GENERATOR SET EPA Certified SNoenary Emergency STANDARD FEATURES ENGINE SYSTEM DI Due e.mmm M Gamer aR Salem moan Fan9us1 Sends Swd howdy EruwmCowden Ewal5N,0rben Dm F4-8ey Rod W 6 Ca11401 Bel System Porgy 9r Fib Coolbellydom MN AC 0*05lrlw Cm0dCoolWeRFwwyslem W Liter RaW11a1Ne9 Fmurydestewsitutwot 5050 UMW@ Germe Arnlmr RAA40r G91e Elwr0AR leclrleal Spam e464y 0mpq Aererb AGM 5W nor boy eaary CtlM S86491144004190101 Fprw Ee4-04 Corec- pry 5010101k00480 SW1e Pow dp1F Clint Brea , ALTERNATOR SYSTEM on WI1 a. Venom Nana 213FIM 81.2 Map AMOLIAIl0l0w9 SN4deeYYq Mar 000002016 UP Minced Ful Lead drably rammer FardheThome SUM. MERRIER SET Su* Ste Sawa wawa* GrweNm16w*Ain Swaim r Wait. NpMew Wwge Sturm We SNw 1Ld1 IIOp Wrpped CANNA Pop Wow flamed Nord Gewaa SVarfmlW4 Wrong LwrOW FlcanTe0N19 12 arm SYNem 20111,61628.2. 256rm Follwp8 cabmen. OENERAC' INDUSTRIAL I Model G007096-0'Sleeh ENCLOSURE Sern*We Dens Atiess4k Floupn l41-00 poll a4m Perommlee 0200-9600e0; larval Cvlelroa00 512zc1 MlmW Laws Sr* OW L4e1 Lock** MT Kry 6 PIOOCM 11100 Coe- . 0084e4 Redder Powder Cate 1566R1 Wind Rare 35' 5206 Rag FUEL TANK UL 142 tamer* 00022412416.402860100 F.M. Pms4re Te4y 15 pal Ruplre Balm Alm iud Lam Gaup ma Sewe Cheek Virg on 5.1622Lae Rnao Loa' - Teond Poeesle Po060 Cain 510126e2 5601026060 16604008 RP Pocket CONTRmLUSTEM ROM H Lrrw PaM - Oval 4211 P,opameple Due UrrW 7-612 21690n200914 Earorm 5204421 Alonami Flopamlesk RC RS-272485 Ccbrrueraemb 1.649oee 5e040 Ydsle RepW Fin Syimm 5u6a 2-NYe SUP 88001400 1101019080e091 Paw radar • MY Nun Tote 6Lau nm Reimnmre,Apbrlml Pow M Pnvie 86 *AIM 80 Meade Cemm 06 Req. Ca104.1e6002108 Ca*W Lear rap9 Speed Badly Wage MODEL OPTIONS Frequency DaleTme ernNan (Ern L601 15009033.0P4 lw DAM W4lr010040 a4Canrann 0o4431 mamma L1d0Pans MP9Ww QW+q Lon 0600310 Nra4 30046 0,360 Pal 31a82e000T1R1 1664110 Fey 1 ay L )PApoa05a36) pmmestie Nam*, WMrp1. W Ewen Abduct rnxr PredC0re 1.14P426000 ANamyn Seabed games Pastime Paanle Aersa,nm Forma, Sept Pon Grand Ger5C s 15 Dane, 0.06 L49609 0.2 8004 (460 Sped Due 109yny reatin We 02940 Aulowneary Comm L9 On Dr DSVuy Menu CONTROL SYSTEM ENCLOSURE 21 Lob Nrupem-Sloped Lam 101ado FW Imlrfd Eawm4 E•SpySrx,m0 Lwow MI PC Fro Ilataler 1.000 Run. Ory Gabler, Nam Nam, Dry C4000 kw Mann- ay Conan Lmr Fsa Nam- Ory Carmel %rare Bate Hann Dry Comte realm 4 Ware tone and 0ale slmoee Hams 4 Wino b Traye4 and slwoy slaw Omaaom SmeSm. Minn Wa1 PD Parameters Drop 1Mm mg Mambo Soler Ore 110 ream C648el c Atannm Ercbtun Eared CPI WraM M'seppq Laze Kc al Fuknsts* SDC20 I 2.5L I 20 kW - AC INDUSTRIAL DIESEL GENERATOR SET EP,'atmnary Emergency DIMENSIONS AND WEIGHTS' Level Sound Mlenuallon Enclosure Run Tee tors 01 WARN ripely 11 3920142, LawMMr bratU 46236490 (121923914. 44226) *PON are1M/ 2100 OM Sowalew 11 PIA mks Emma, NAM.- Umbra Loose MA ro 400 120644 GENERAC INDUSTRIAL Model G007098-0 ISteeP • At 8e4saeme825 ale ammermee and b geesml 110110620 nee YOUR FACTORY RECOG120II1) GEREMC INDUSTRIAL 0E11E19 e000e114004 Spam Ix 1 P082•81 weriMU VA531M 6 126216w-011 C.bl6 Gomc FMr Worm 29 PA vie num, N wrmcaem as worm s cap 1 0 00 110r060860 10000009319 a« W0110210 SDC20 I 2.5L I 20 kW - AC INDUSTRIAL DIESEL GENERATOR SET EPA Carolled SlebeRary Emergency APPLICATION AND ENGINEERING OAT/. ENGINE SPECIFICATIONS G019ri MNa rlaBM1 Coma ( Sy SUM, Cml19 Sylam Type OENERAC INDUSTRIAL Model G0- Steslf Feted 0e008401 EPA EyNom Conswnce MWn Up Type Petlacertae - L Me N Bee mm(n) efiw•2140 Camvlessmn Wm ,µre 2511710 881351 IO3(41) 22T nine M Penn Nrrry Atoned En5ne Governing Gomm, Electronic Iwelvmm. Fropuen y neprem alstl4 slap a 0251 W24142000 Syrem dFIFotub Tpda48ea Polo CPOwTam Fiume Paper. EA Flmr Cum.. Gomm • L 1ps1 65 (691 W4r Pone type GNAW. Faro Fan 1Fm Rae Fan Spree errel Fan gamey • me, imp Cal. flew Waage 30121 4319(12) 1006 Coabre MValege Fuel Syo9om 120 Utra Lae Stir Okeel 42 l,rel Spallllmeae Fred Mune "MAD Fuel sera Pm9 NM Bosch WIMP nype Enp a D11021 din Elpre Lg. D90e1 reel SpW Lem• mini 0nl Em96N Elected Syslem Sylwm V0Op Bnrr CNper Ammar 66 U1261 t2411C 1805021. emay Ste. 133tIMY G100p 81e0). Vamge Greene weer 656 GOA 35 12 4DC Noma ALTERNATOR SPECIFICATIONS 59.,5 U:cc: Mae Ale POT 28-2114 Pd 4 Fed Typo Rending Ir0W.AR Class • Rear Lawmon tins . 5010 N SPAM Dui Sealed Cep* SA. Raw UM Omagh - 51nm01' Three, SITAR Cann rev 100S Vet MVP RepAam Typ DORN Totenanml 13v0,a9 o0% Ttl9Ooae Ymrrence Flew (1121 445 5100481 E.smnm Nu,Cer d SmedFlwes M Rrgium,lerafcleMabry We) e0351 RATING DEFINITIONS sway • AMPclb Mr a rawm emmerry dam Ile de moan eel 1 may power em1e sMT m o.ewao 630,010F GRP C ITYSWIT C H it .OU UTA.I N LTD. MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 0 V 0 rry�y� PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 `1yeAElr..a1/ell ley Ar t� SC y IT IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. GENERATOR DETAILS SHEET NUMBER: C-3.1 CASE # 20-08-GCCP-05794 132151_NCC019_CD TOTAL STRUCTURE HEIGHT = 230' TO TOP OF LIGHTNING ROD 220' TO TOP OF TOWER PROPOSED 10' LIGHTNING ROD PROPOSED (2) DC POWER CABLES, (1) FIBER TRUNK PROPOSED AT&T CARRIER GROUND EQUIPMENT I I I I I I fi I I I I I I I i i FLASHEAD (SEE NOTE #3) PROPOSED AT&T ANTENNA ARRAY RAD CENTER=215'AGL FUTURE ANTENNA ARRAY RAD CENTER=205' AGL FUTURE ANTENNA ARRAY RAD CENTER=195'AGL FUTURE ANTENNA ARRAY RAD CENTER=185'AGL FUTURE ANTENNA ARRAY RAD CENTER=175'AGL FUTURE ANTENNA ARRAY RAD CENTER=165'AGL FAA El -DUAL MEDIUM INTENSITY 7 STROBE NAVIGATIONAL HAZARD LIGHTING SYSTEM (SEE NOTE 3) NOTE: THESE DRAWINGS ARE NOT INTENDED TO REFLECT THE STRUCTURAL INTEGRITY OF THE TOWER. THE PROPOSED ANTENNAS AND TRANSMISSION LINES SHOWN ARE REPRESENTATIVE IN NATURE AND DO NOT REFLECT THE ACTUAL CONFIGURATIONS REQUIRED. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ANALYSIS OF THIS TOWER SITE FOR THE APPROVED LOCATION AND CONFIGURATION OF ALL ANTENNAS AND TRANSMISSION LINES. ALL ANTENNAS MUST BE MOUNTED AND THE TRANSMISSION LINES CONFIGURED IN STRICT ACCORDANCE WITH THE STRUCTURAL ANALYSIS. STRUCTURAL ANALYSIS NOTES: 1. ANTENNA PLACEMENT WAS DETERMINED WITHOUT VERIFICATION OF STRUCTURAL ANALYSIS. 2. REFER TO STRUCTURAL ANALYSIS OR STRUCTURAL LETTER FOR APPROVAL OF ADDITIONAL NEW APPURTENANCES. 3. TOWER WILL BE PAINTED AND OR LIGHTED IN ACCORDANCE WITH FM AND LOCAL REGULATIONS. CLIMBING LADDER W/ SAFETY CABLE START 12' ABOVE FINISHED GRADE PROPOSED TOWER ELEVATION SCALE: N.T.S. NOTES: CONTRACTOR TO REFER TO THE STRUCTURAL DESIGN REPORT PREPARED BY UNITI TOWERS PRIOR TO CONSTRUCTION. NOTE: SEE ANTENNA AND RRH SCHEDULE ON SHEET C-5. MAX ANTENNAE PLATFORM WIDTH = 15' TYPICAL ANTENNA MOUNTING PLAN SCALE: 0' 1' 2' 4' NEW AT&T DC6 SQUID MOUNTED TO ANTENNA PIPE (TOTAL OF 3) Ispo. NEW AT&T ANTENNAS TO BE INSTALLED (2 PER SECTOR. TOTAL OF 6) NEW AT&T RRHS TO BE INSTALLED (5 PER SECTOR. TOTAL OF 15) 10' =IF B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 .O� Q' Eg �otiti / 0... R IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. FT OWER ELEVATION & ANTENNA ORIENTATION SHEET NUMBER: C-4 CASE # 20-08-GCCP-05794 User: mspeedie dwg — Sheet:C 132151_NCC019_CD ANTENNA AND RRH SCHEDULE SECTOR ANTENNA MODEL MECHANICAL DOWN TILT ELECTRICAL DOWN TILT TECHNOLOGY AZIMUTH ANTENNA HEIGHT RRH MODEL SURGE SUPPRESSION CABLE CABLE LENGTHS ALPHA TPA-65R-BU8DA-K 0° 0/0 LTE 700 LTE WCS p° 215' (1) B5/B12 4449 (1) 4415 B30 (1) DC6 RAYCAP 1 () FIBER (2) DC FIBER 265' DC 265' NNH4-65C-R6 0° 0/2 LTE 700 LTE AWS LTE 1900 0° 215' (1) B14 4478 (1) 4415 B25 (1) 4426 B66 BETA TPA-65R-BU8DA-K 0° 0/0 LTE 700 LTE WCS 120° 215' (1) B5/B12 4449 (1) 4415 B30 (1) DC6 RAYCAP (1) FIBER (1) DC FIBER 265' DC 265' NNH4-65C-R6 0° 0/2 LTE 700 LTE AWS LTE 1900 120° 215' (1) B14 4478 (1) 4415 B25 (1) 4426 B66 GAMMA TPA-65R-BU8DA-K 0° 0/0 LTE 700 LTE WCS 240° 215' (1) B5/B12 4449 (1) 4415 B30 (1) DC6 RAYCAP (1)FIBER (2) DC FIBER 265' DC 26655 ' NNH4-65C-R6 0° 0/2 LTE 700 LTE AWS LTE 1900 240° 215' (1) B14 4478 (1) 4415 B25 (1) 4426 B66 0 ANTENNA CONFIGURATION SCALE: -- BEFORE INSTALLING ANY EQUIPMENT, CONTRACTOR MUST CHECK WITH PROJECT MANAGER AND RF ENGINEER FOR MOST RECENT RF CONFIGURATION SHEET. =IF B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES 1 U H FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 0 C7 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 r111...IV `t%.'fff • - Q' `ES 1otiti / : SE' C / • q r. / , IT IS A 1OLA THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. '4'4,, • �lT�N►�r 5/0' TON OF LAW FOR ANY PERSON UNLESS ANTENNA CONFIGURATION SHEET NUMBER: C-5 CASE # 20-08-GCCP-05794 User: mspeedie dwg — Sheet:C 132151_NCC019_CD 0 ANTENNA WEIGHT: 87.5 LBS PLAN _ co. rn ELEVATION TPA-65R-BU8DA-K ANTENNA DETAILS SCALE: N.T.S. 0 19.6" ANTENNA WEIGHT: 87.3 LBS PLAN _ co. ELEVATION NNH4-65C-R6 ANTENNA DETAILS SCALE: N.T.S. RRH WIDTH DEPTH HEIGHT W/0 CABLE MANAGEMENT COVER WEIGHT W/0 BRACKET B5/B12 4449 15" 8.1" 15" 70.3 LBS B30 4415 12.05" 5.51" 13.25" 34.17 LBS B14 4478 23" 6.3" 12.6" 53 LBS B25 4415 11.97" 7.18" 21.2" 52.9 LBS B66 4426 12.1 " 7" 27.2" 53 LBS NOTE: DIMENSIONS INCLUDE SOLAR SHIELD BUT NOT MOUNTING BRACKET. REMOTE RADIO HEAD (RRH) SCALE: N.T.S. WIDTH ■ 1— w RAYCAP SUPPLIED MOUNTING BRACKETS RAYCAP DC6 OVER VOLTAGE PROTECTOR WITH DOME COVER DOME SECURING BAND CLIP FOR ATTACHING DC6 (OVP) TO BASE ASSEMBLY (TYP) RAYCAP SUPPLIED BASE ASSEMBLY POWER CABLE INGRESS PORTS CABLE TIE BAR RAYCAP DC6-48-60-18-8C (SQUID) SCALE: N.T.S. =IF B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 Z O V 0 17-1 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 . Q � sti>e It • ��``,```� IT IS A WOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. RRH, ANTENNA & EQUIPMENT SPECIFICATIONS SHEET NUMBER: C-6 CASE # 20-08-GCCP-05794 E D dwg — Sheet:C 151_NCC019_CD ALSG 2 i npo rta nt Note : Fa' demiled redo toanion. WON rekr to the latest 4T4R Antenna f R.Krho PortCcionectlen Mild Mo*.(I1F-HW.201b294) and the 47 W ri rtg PN3yhook MOMS x x x x x it X ) x at PC•7JAWOSMCW ,. x X X x XIX u x x x x X X X x X X X X F11170RVS Dc,F ber arCa0on 5a IB M HEM 0 RF PLUMBING DIAGRAM SCALE: N.T.S. PROVIDED BY AT&T B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 z O V PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 :�•,pQ. Q� j Es rotiiNC ti>e~ooioouor �lT00000 oo FOR ANY PERSON UNLESS IT ISA VRMATON OF LAW THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. RF PLUMBING DIAGRAM SHEET NUMBER: C-7 CASE # 20-08-GCCP-05794 User: mspeedie 132151_NCC019_CD GENERATOR NOTES; 1. CONTRACTOR SHALL COORDINATE INCOMING SERVICES WITH LOCAL UTILITIES PRIOR TO TRENCHING. 2. ALL CONDUCTORS SHALL BE COPPER, 75 DEGREES C RATED, AND CONDUCTOR INSULATION SHALL BE THWN OR THHN. 3. ALL TERMINATIONS SHALL BE LISTED AND IDENTIFIED FOR USE WITH 75C RATED CONDUCTORS OPERATING AT 75C. 4. GROUND FAULT PROTECTION REQUIRED FOR UT1Lf1Y RECEPTACLES. 5. SERVICE NEUTRAL SHALL BE GROUNDED AT ONE LOCATION ONLY. 8. WHITE/NEUTRAL. GREEN/GROUND SHALL BE MAINTAINED THROUGHOUT THE SITE ELECTRICAL SYSTEM (TAPE WILL NOT BE ACCEPTABLE) 7. EQUIPMENT LOCATED OUTSIDE OR EXPOSED TO MOISTURE SHALL BE NEMA 3R RATED 8. CONTRACTOR SWILL USE SCHEDULE 80 PVC CONDUIT THROUGHOUT, UNLESS OTHERWISE NOTED. 9. ALL NEWLY INSTALLED EQUIPMENT SHALL BE RATED AT 10K A/C MINIMUM. HIGHER RATINGS SHALL BE REQUIRED WHERE AVAILABLE FAULT CURRENT EXCEEDS THIS VALUE EXACT FAULT CURRENT AVAILABLE SHALL BE COORDINATED WITH LOCAL UTILITY BASED ON EXACT CONDITIONS (TRANSFORMER SIZE, PERCENT IMPEDANCE, LENGTH OF CONDUCTORS, ETC.) 10. ELECTRICAL CONTRACTOR TO VERIFY ADDITIONAL/PROPOSED LOADING DOES NOT EXCEED SYSTEM CAPACITY. PLEASE NOTIFY AT&T WITH ANY DISCREPANCIES. 0 EXISTING INCOMING TELCO SERVICE FROM LOCAL DEMARCATION POINT NOTES BY SYMBOL OEXISTING UTILITIES AND EQUIPIAEN�POWER PLANT CABINET IS IN PLACE SHOULD BE USED TO ‘T.1 MANUFACTURED BY EMERSON AND FEED NEW CABINETS INDICATED. CSA/UL RATED. ILL_ ITEMS SHOWN WITHIN CABINET ARE PROVIDED WIl ®UNIVERSAL POWER CABINET (UPC) THE CABINET ARE PROVIDED WITH IS SERVICE ENTRANCE RATED, THE CABINET AND ARE SHOWN FO MEETING UL 67 AND UL 50. ALL REFERENCE ONLY UNLESS NOTED ITEMS SHOWN WITHIN CABINET ARE OTHERWISE. PROVIDE THE PROVIDED WITH THE CABINET AND CONNECTIONS INDICATED. OBTAIN ARE SHOWN FOR REFERENCE ONLY POWER CABINET DRAWING FOR UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL INFORMATION. THE CONNECTIONS INDICATED. OBTAIN POWER CABINET DRAWING$/1THE CONTRACTOR SHALL REFER R FOR ADDITIONAL INFORMATION. THE FLX16 LTE CABINET AND OTHE CONTRACTOR SHALL FURNISH EQUIPMENT INSTALLATION MANUALS, THEAND INSTALL A 1 2 POLE SPECIFICATIONS. AND AT&T LTE BREAKER WITHIN ETHETH EXISTING UPC CONSTRUCTIONS GUIDELINES FOR ITI TO FEED THE PROPOSED NECSARL INFORMATION NOT DISTRIBUTION PANEL "SUBPANEL". TDRILY INCLUDED WITHIN TYPE AN AIC RATING OF BREAKER THESEHESE DRAWINGS. SHALL MATCH EXISTING (SQ D Q(t)THE CONTRACTOR SHALL REFER TO WHERE NO SPACE IS AVAILABLE, EQUIPMENT DRAWINGS AND CONSOLIDATE RECEPTACLE CIRCUITS SPECIFICATIONS FOR CONTROL AND AND PROVIDE MINI —TWIN BREAKER ALARM WIRING. INTERIOR ALARMS TO CREATE SPACE. (IF REQUIRED) ARE PRE —WIRED. 4 PROVIDE AND INSTALL 24VDC TO OWHERE REQUIRED, PROVIDE —48VDC CONVERTERS WITH 9 POWER, ALARM, AND FIBER DISTRIBUTION BOARD WITHIN CONNECTIONS TO THE 6601 AS EXISTING AUX II CABINET. INDICATED. COORDINATE WITH AT&T OCONTRACTOR SHALL PROVIDE ALL CONSTRUCTION MANAGER. AC CIRCUIT BREAKERS REQUIRED ZAN SIAD'S SHALL BE FED FROM THE 2 FEED AT&T EQUIPMENT. DC CIRC CABINET THEY ARE LOCATED WITHIN BREAKERS SHALL BE PROVIDED BY (UPC OR LIE) AT&T. CONTRACTOR SHALL LABEL ALL CIRCUIT BREAKERS WITH RESPECT TO WHAT THEY FEED. 0 EXISTING INCOMING POWER SERVICE FROM LOCAL DEMARCATION POINT TELCO I PLYWOOD TELCO I BOARD I FURNISHED WITH I POWER CABINET 4 —I POWER L_J I 1)� I I L22w2PI [ — J SMGB GROUND RING CO EXISTING 125A SUBPANEL 1 1 125A MLO [20A 20A _ J 20A 20A u UNIVERSAL 2 POWER CABINET O (UPC) 1 C2 AWG GROUND RING CU AWG—y_ GROUND L RING L MARK CONDUIT CABLE REVARK5 QTY. SIZE QTY. SIZE GROUND SIZE 0 1 SCH 80 2' 3 ill /6 AC POWER FROM UPC TO SUBPANEL (ASSUMED SIZE) 2 H O(QUAMY 1 SCH 80 1-1/2' 6 #8 AC POWER FROM SUBPANEL TO POWER PLANT (POWER FOR RECTIFIERS) OF CONDUCTORS INDICATED IS PER BREAKER) I ® 1 SCH 80 1' 3 112 #12 PC POWER FROM SUBPANEL TO ANCILLARY EQUIPMENT IN POWER PLANT 0 1 2' BELDN CABLES ALARM CONTROL FROM POWER PLANT TO FLX16 ® 1 2' FIBER 18—PAIR (FB—L988—A0213—)XX) FIBER FROM UPC TO FLX16, SWEEPING BENDS 6 1 2' BELDN CABLES ALARM CONTROL FROM UPC TO FLX16 7 1 2' 1 12 /2 DC POWER FROM POWER PLANT TO LTE PDB 0 1 2' 12 #8 j8 DC POWER FROM POWER PLANT TO DC-6 SURGE SUPPRESSOR 0 -- -- 3 FIBER 18—PAIR (FB—L98B-034) FIBER FROM FLX16 TO RRUs, SWEEPING BENDS m' -- -- 5 3PR DC #8 AWG DC POWER FROM DC-8 SURGE SUPPRESSOR TO RRUs SCOPING NOTES — — — — — — — NSTALL NSTALL NSTALL NSTALL NSTALL NSTALL NSTALL 3 TPA-65R—BU80VA—K ANTENNAS — INSTALL 13 NNH4-65C—R6 ANTENNAS — INSTALL 13 RRUS-4449 B5/B12 — INSTALL 13 RRUS-8843 B2/B86A — INSTALL 13 RRUS-4478 B14 — INSTALL 13 RRUS-4415 B30 — ADD FIBER '6 B2B DUAL RRU MOUNTING BRACKETS 3 RAYCAP DC6-48-60-18-8C 3 FIBER TRUNKS 5 DC POWER TRUNKS 3 KENW00D T1672KT12 SECTOR FRAMES 12) P1090KT10 ANTENNA MOUNT PIPES JUMPER & A CAT 6 FOR TRANSPORT FOR FIRSTNET 000 POWER PLANT HT —RECTIFIER SHELVESJI II—128VDC AND 24VDC II LI 1 ,—,LL —RECTIFIERS I1_ANCILLARY EQUIPMENT r r• r r UPPER DC DISTRIBUTION CENTER r24 POSmON-48VDCj] DISTRIBUTION PANEL _ II__ II J 20A_ II 3E01 II • —�I _J • —4 J 31140-- --- 4 -I II 30 37; II - Lam__ _0-- - 0- - 0- - 0- - 0- - 0- - 0- - 0 u rr--BATTERY--i II c 0I"IPPANGEr II Lam_ --�J 0 DC / FIBER SYSTEM DIAGRAM SCALE: N.T.S. DC 6 SURGE SUPPRESSOR DC 6 SURGE SUPPRESSOR DC 6 SURGE SUPPRESSOR 000 LTE CABINET TO RAYCAP TO RAYCAP TO RAYCAP — 10 --- TO RAYCAP — 10 CABLES ROUTED TO THE RRUS/ANTENNAS VIA SQUID (SEE SHEET #) — 10 — 10 CABLES ROUTED To THE RRUS/ANTENNAS VIA SQUID (SEE SHEET #) TO RAYCAP — 10 — TO RAYCAP — 10 CABLES ROUTED TO THE RRUS/ANTENNAS VIA SQUID (SEE SHEET I) TO RAYCAP 0 1 CU AWG GROUND RING PROVIDED BY AT&T =IF B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 0 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 t,.rrr••r►rTT,f�� �:�NCA O ff4-, :p Q' `ES rotiti /`P,�°� q SE IT IS A VRTLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. DC / FIBER SYSTEM DIAGRAM SHEET NUMBER: C-8 CASE # 20-08-GCCP-05794 Oct 25, 2021 E 151_NCC019_CD (" COMPACTED 6" CRUSHER RUN (ABC) AGGREGATE SHALL CONFORM TO DOT STANDARDS FOR AGGREGATE ROADWAYS COMPACTED WITH ROLLER 2' SHOULDER MATCH EXISTING (TYP.) GRADE 0 \___ 6" COMPACTED SUBGRADE COMPACT TO 98% DENSITY IN ACCORDANCE WITH AASHTO T99 NOTES: MATCH EXISTING GRADE 1. THE CONTACTOR MUST EITHER SUPER -ELEVATE OR CROWN ALL ROAD SECTIONS. 2. THE MAXIMUM SUPER -ELEVATION SHALL NOT EXCEED 6% CROSS SLOPE. ON GRADE GRAVEL ROAD SECTION STAKE HEIGHT SCALE: N.T.S. L_ NOTE: 1. FENCE SHALL BE WIRE REINFORCED. SILT FENCE DETAIL STEEL POST WITH SPACING © 4' MAX. PLACE PLACE PARALLEL TO CONTOURS WIRE FABRIC MIRAFI 100X FILTER FABRIC OR EQUAL (WOVEN WIRE FENCE BACKING) FLOW 6" X 12" TRENCH - BACKFILL WITH CRUSHED STONE WIRE FABRIC 12" DEEP STEEL POST SHALL BE MIN. 30" ABOVE GROUND AND MIN. 18" BELOW GROUND FABRIC LENGTH 28" ABOVE GROUND 12" BELOW GROUND SCALE: N.T.S. AT&T CONSTRUCTION 0 WAVEGUIDE BRIDGE SUPPORT ■ BRACKET OR APPROVED EQUAL 1=.COMMSCOPE PART# WB-LB12-3.06 IH' I ,LJ -lilt I I UNISTRUT P5501 OR EQUIVALENT 3-1/2"0 GALVANIZED STEEL PIPE #2 AWG SOLID TINNED COPPER GROUND CONDUCTOR CADWELD TO POST CROWN FOOTING 4000 PSI MIN. CONCRETE FOOTING NOTE: ALL SUPPORT POSTS MUST BE GROUNDED ICE BRIDGE DETAIL SCALE: N.T.S. PIPE MOUNT KIT COMMSCOPE PART# GP-S24 (OR EQUAL) CABLE BRIDGE POST OR SIMILAR POST GPS ANTENNA 1-1/2"0X3'-0" MAX GALVANIZED STEEL MOUNTING PIPE GROUND KIT 6 AWG GROUND WIRE TO CADWELD ON POST OR LUG ON GROUND BAR COAX CABLE (AS REQUIRED BY ANTENNA MANUFACTURER) GPS ANTENNA MOUNTING DETAIL SCALE: N.T.S. =IF B+T GRP C ITYSWIT C H M.OUHTAJN LW. MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 Z O V 0 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION INE.����•` ,� ►yti+rS�Fi R IS A VIOLATION OF LAW FGR A Y PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. ENGINEERING DETAILS SHEET NUMBER: C-9 CASE # 20-08-GCCP-05794 STRUCTURAL TEfr. 0 151_NCC019_CD (' 1. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED BY FIELD MEASUREMENT. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH CONSTRUCTION. 2. THE GENERAL CONTRACTOR AND HIS SUB CONSULTANTS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS WHICH MAY BE REQUIRED FOR THE WORK. 3. STRUCTURAL STEEL SHALL CONFORM TO SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, AISC 360-05 INCLUDING THE COMMENTARY AND THE AISC CODE OF STANDARD PRACTICE. 4. STRUCTURAL STEEL PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36. STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B. STRUCTURAL STEEL BEAMS SHALL CONFORM TO ASTM A992, GRADE 50. ALL STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500 GRADE B. ALL STRUCTURAL COMPONENTS AND FABRICATED ASSEMBLIES SHALL BE HOT DIP GALVANIZED—ASTM A123 AFTER FABRICATION. FIELD TOUCH UP WITH 3 COATS OF ZINC RICH PAINT ALL TAW EDGES AND/OR AREAS WHERE THE GALVANIZED FINISH HAS BEEN DISTURBED (ALL EXISTING AND NEW AREAS). 5. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS D1.1). STRUCTURAL WELDING CODE —STEEL WELD ELECTRODES SHALL BE E70XX. FIELD TOUCH UP WITH ZINC RICH PAINT (ALL EXISTING AND NEW AREAS) AFTER WELDING COMPLETE. 6. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLIES SHALL CONFORM TO ASTM A 307 OR ASTM A36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. FASTENERS SHALL BE 5/8 INCH MIN. UNLESS NOTED OTHERWISE, DIAMETER BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED IN THE SHEAR PLANE. ALL EXPOSED FASTENERS, NUTS AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. CONCRETE EXPANSION ANCHORS SHALL BE HILT! KWIK BOLTS UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL. 7. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60, DEFORMED BILLET STEEL BARS. WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A185. 8. CONCRETE FOR THE FOUNDATION PAD SHALL BE 4000 PSI NORMAL WEIGHT CONCRETE. CONCRETE STRENGTH SHALL BE VERIFIED BY CONCRETE CYLINDER TESTS (A MINIMUM SET OF FOUR CYLINDERS). PROVIDE 4 TO 6% AIR ENTRAINMENT FOR ALL CONCRETE SUBJECT TO FREEZE — THAW CYCLE. 9. MINIMUM CONCRETE COVER REINFORCEMENT SHALL BE 2" UNLESS NOTED OTHERWISE . CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH SHALL HAVE A MINIMUM CONCRETE COVER OF 3". 10. CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, CONDUIT, CHAMFERS, AND EMBEDDED ITEMS PRIOR TO CONCRETE PLACEMENT AND/OR STEEL ERECTION. CONTRACTOR SHALL VERIFY ALL SIZES AND LOCATIONS. 11. DO NOT IMPOSE SERVICE LOAD (I.E. FLOOR DEAD AND LIVE LOADS, BACKFILL, ETC.) UNTIL THE CONCRETE HAS REACHED ITS SPECIFIED MINIMUM COMPRESSIVE STRENGTH. 12. BACKFILL SHALL BE CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED. CLEAND SAND FILL SHALL BE FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL. 13. SOIL SHALL BE COMPACTED TO 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY TO A MINIMUM OF 2 FEET BELOW THE BOTTOM OF THE FOOTINGS, AND SHALL OBTAIN A 2000 PSF MINIMUM ALLOWABLE BEARING CAPACITY. 12' 0 #5 © 12" O.C. ■■E AI•••U v z 2 6" 4000 PSI CONCRETE SLAB WITH #5 ® 12" O.C. EACH WAY ON 6" THICK COMPACTED AGGREGATE BASE COURSE MATERIAL OVER GEOTEXTILE FABRIC CONCRETE PAD PLAN SCALE: NTS 6' CI FINISHED GRADE TYP #5 0 12" O.C. EACH DIRECTION (CENTERED IN SLAB) 6" THK COMPACTED AGGREGATE BASE COURSE MATERIAL OVER GEOTEXTILE FABRIC (TYP) UNDISTURBED SOIL W/ MIN 2000 PSF BEARING CAPACITY 3" GALV SCH 40 PIPE WITH CAP AND GALVANIZED HARDWARE UNISTRUT CROSS MEMBER, AS NEEDED (TYP) 3" GALV ANGLE (THIS MEMBER ONLY) CROWN TOP PIER FOR DRAINAGE • H-FRAME ELEVATION DETAIL SCALE: NTS CONCRETE PIER (MIN 4000 PSI CONCRETE) #4 STIRRUPS 12" O.C. 1" CHAMFER (TYP) TOP OF SLAB = 6" A.G.L. FINISHED GRADE TOP OF SLAB = 0" A.G.L 3" CLEAR COVER (TYP) (4) #4 BARS ALL AROUND 1.5' (TYP) CONCRETE PAD SECTION SCALE: NTS EQUIPMENT CABINET (TY) INSTALL CABINET PER MANUFACTURER'S SPECIFICATIONS 5/8"0 EXPANSION BOLT OR SLEEVE ANCHOR EMBED MINIMUM 4". PROVIDE ONE BOLT PER CABINET CORNER (TYP OF 4) MOUNTING SLED (TYP) CONCRETE SLAB FINISHED GRADE 6" MIN EDGE DISTANCE CABINET CONNECTION DETAIL SCALE: NTS -p B+T GRP C ITYSWIT C H i .OU TLATI:1 LTD. MOUNTAIN LTD, WIRELES U U z FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 E. Z O V PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION r. r. B&T ENGINEERING, INC. C-4171 TT.,,�flr ,'Ai' DES 1c57 /-v'.��� SE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ENGINEERING DETAILS SHEET NUMBER: C-9.1 CASE # 20-08-GCCP-05794 USE A MINIMUM OF 2 STAKES ON UPSLOPE SIDE MIN. 2 STAKES ON UPSLOPE GROUND •�'L`• 11111=1 I I111=II I USE A MINIMUM OF 4 STAKES ON DOWNSLOPE SIDE PLAN VIEW MINIMUM 4 STAKES ON DOWNSLOPE =III= MATTING I11 II -I1 V-DITCH SECTION VIEW III; ..III I 11-11 E1 MIN. 2 STAKES ON UPSLOPE GROUND II=11=111=1 —lil=l I I=I I I I-1 MINIMUM 4 STAKES ON DOWNSLOPE it''-1 I - 11 l a i= MATTING TRAPEZOIDAL DITCH SECTION VIEW ISOMETRIC VIEW NOTES: 1) USE A MINIMUM 12 INCH DIAMETER EXCELSIOR WATTLE. 2) USE 24 INCH LONG WOODEN STAKES WITH A 2"x2" NOMINAL CROSS SECTION. 4) INSTALL WATTLE(S) TO A HEIGHT ON SLOPE SO FLOW WILL NOT WASH AROUND WATTLE AND SCOUR SLOPES, OR AS DIRECTED. 5) INSTALL A MINIMUM OF TWO UPSLOPE STAKES AND FOUR DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO GROUND AT BOTTOM. 6) PROVIDE STAPLES MADE OF 0.125 INCH DIAMETER STEEL WIRE FORMED INTO A U-SHAPE NOT LESS THAN 12 INCHES IN LENGTH. 7) INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. 8) AFTER INSTALLATION OF STAPLES, CHINK ANY GAPS BETWEEN WATTLE AND GROUND WITH MATTING. WEAVE STAPLES THROUGH MESH CASING OF WATTLE 11�1--III� TAPLES ` - STAPLES STAPLE INSTALLMENT SECTIONS MATTING WATTLE DETAIL SCALE: N.T.S. Ti STAKES ANGLE STAKES TO WEDGE WATTLE ONTO GROUND II=\"El 1=1 11_111=11-I 1 I III i MATTING STAKE INSTALLMENT CROSS SECTION B+T GRP C ITY� C H MODUTAIPii LTD. MOUNTAIN LTD, WIRELES U z FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 O V 0 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 jeS 0 1 e*".tAk 'd K• ►► ,V C 21 0 IS A VIOLATION OF LAW FOIrANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ENGINEERING DETAILS SHEET NUMBER: C-9.2 CASE # 20-08-GCCP-05794 151_NCC019_CD (' 727 726 725 724 723 722 PROPOSED TOP OF DRIVEWAY (MAINTAIN 1' MIN COVER OVER TOP OF PIPE) H J 25' ACCESS EASEMENT EXISTING DRIVEWAY SURFACE - FG=725.7 T.O.P.=724.50 IE=722.80 PROPOSED 18" ADS N-12 HDPE PIPE W/ END SECTIONS OR APPROVED EQUAL, 20% 721 ----- STREAMBED BURIAL - EXISTING 12" RCP STORM DRAIN, W/ INVERT PERCHED APPROX 2" ABOVE FLOW LINE 14' 1- FG=f26.2 T.O.P.=724.61 L - EXISTING GROUND ' SURFACE --- 0 STORM DRAIN PROFILE PIPE END SECTION (T'P) SCALE: N.T.S. 727 726 725 724 723 722 721 B+T GRP C ITYSWIT C H M.OUHTAIN LTD. MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 E. Z p O V PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 CA,,� SE ` T 0 IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. ENGINEERING DETAILS SHEET NUMBER: C-9.3 CASE # 20-08-GCCP-05794 151_NCC019_CD (' FENCE NOTES 1. USE 3,000-PSI CONCRETE, FULLY CONSOLIDATED AROUND THE POST. 2. WHERE THE POST IS SET IN ROCK OR CONCRETE, CORE A HOLE 12" DEEP AND 1" LARGER IN DIAMETER THAN THE POST. SET THE POST AND GROUT IN PLACE USING NON -SHRINK GROUT. 3. ALL POSTS MUST BE PLUMB AND ALIGNED WITH ONE ANOTHER IN BOTH HORIZONTAL AND VERTICAL PLANES. 4. CORNERS AND GATEPOSTS FOR CHAIN LINK FENCES SHALL EXTEND ABOVE THE TOP STRAND OF BARBED WIRE TO PROVIDE TENSIONING FOR THE BARBED WIRE. 5. PROVIDE MIDRAILS AND BRACING AT ALL CORNER POSTS WHERE THE FENCE CHANGES DIRECTION BY MORE THAN 30 DEGREES. 6. THE GRADE OF THE SITE AND INSTALLATION OF THE FENCE SHALL PROVIDE FOR NO MORE THAN A 1" GAP BETWEEN THE BOTTOM OF THE FENCE MATERIAL AND FINISH GRADE. 7. CONTRACTOR SHALL PROVIDE HOLD OPEN DEVICES FOR ALL GATES AT THE SPECIFIED OPEN POSITIONS, DRIVEN PIPE TYPE RECEIVERS ARE NOT AUTHORIZED. 8. CONTRACTOR SHALL ALSO PROVIDE A MUSHROOM TYPE RECEIVER AT THE CLOSE POSITION. 9GA2"x2" FENCE FABRIC Y8" STEEL TRUSS ROD AND TRUSS ROD TIGHTENER AT ALL CORNERS (TYP.) 3 STRANDS OF 12 GA. GALV. BARED WIRE WITH 4-POINT BARBS o? \milIIIMIMIONOMMOMMI \ 1101OWIMINIOMMI INEHINIMOMNIONMIIME z 0 Co ha DUCK BILL OPEN GATE HOLDER. VERIFY LOCATION IN FIELD PRIOR TO INSTALLATION. 1'-0" (TYP) CONTRACTORS TO PROVIDE STYMIE LOCK OR APPROVED EQUIVALENT INDUSTRIAL HINGE - 180° (TYP) —COMMERCIAL FABRICATED 1.90" O.D. GATE FRAME 10" (TYP) 6'-0" 1.375" O.D. GALV. PIPE FOR MUSHROOM STOP MUSHROOM STOP 6'-0" 2.375" O.D. STANDARD GALV. LINE POST 1.66" O.Q. STANDARD GALV. PIPE XXXX 1 XXXXXX M M N !i XXXXX 12'-0" TYPICAL FENCE AND GATE DETAIL SCALE: N.T.S. RAIL END CONNECTOR (TYP) 1' GAP BETWEEN FENCE AND GRAVEL 8'-0" O.C. MAX )f X M X X x M X X u XXXXXXXXX 1.66" O.D. STANDARD GALV. RAIL AND BRACE PIPE (TYP) x v, SEE NOTES —7 GA. GALV. TENSION WIRE SEE NOTES 2.875" O.D. STANDARD GALV. CORNER AND GATE POST STEEL GALV. TENSION BAR TENSION/BRACE BAND (TYP) FINISHED GRADE 1 10" (TYP) FINISH GRADE MUSHROOM STOP, INSTALL WITH SLOT PARALLEL w/ CLOSED GATES FENCE GRAVEL COMPOUND MATCH EXISTING GRADE 10" 0 CONCRETE FOOTING 24" DEEP MUSHROOM STOP DETAIL SCALE: N.T.S. 6" COMPACTED SUBGRADE COMPACT TO 98% DENSITY IN ACCORDANCE WITH AASHTO T99 GRAVEL COMPOUND COMPACTED 6" CRUSHER RUN ABC COMPACT W/ ROLLER TENCATE MIRAFI BXG 12 UNDER ALL GRAVEL SURFACES SITE COMPOUND SURFACE DETAIL SCALE: N.T.S. MATCH EXISTING GRADE 3-WIRE 45° BARBED WIRE ARM w/ 3-STRANDS OF BARBED WIRE (TYP) z 0 Co zw wQ ° m 0 aQ Qw 0 0 Z Lu TOP RAIL CHAIN LINK FABRIC LINE POST 8'-0" O.C. MAX FINISH GRADE FENCE SECTION DETAIL SCALE: N.T.S. =IF B+T GRP C ITYSWIT C H M.OUHTAINk LTID. MOUNTAIN LTD, WIRELES FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 0 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION IN OF LAW ..............ANY PERSON UNLESS R IS A VIOLATION THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. FENCE, GATE, AND COMPOUND DETAILS SHEET NUMBER: c-10 CASE # 20-08-GCCP-05794 132151_NCC019_CD (11).dwg — Sheet:C-11 — BLACK TEXT 24" C ITYSWITCH SITE NAME: NCC019 SITE NUMBER: FA10142260 SITE ADDRESS: FCC Tower Registration # 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 In case of Emergency, dial 911 NO TRESSPASSIN For Leasing Information: For Operations & Access: TBD 30" WHITE BACKGROUND, RED/BLACK LETTERING MOUNTING LOCATION: SHELTER OR TENANT IMPROVEMENT ROOM DOOR. IF OUTDOOR CABINET SITE PLACE ON END CABINET CLOSEST TO SITE ACCESS POINT. PLACE ON GENERATOR QUANTITY: 1 TO 2 .� PROPERTY OF UNITI TOWERS NOT TO SCALE 8" BLACK GREEN TEXT BACKGROUND 12" INFORMATION ` Ile realrl a e. 0r00•01 war. wloe Jere ear 1.M 000.s ewlwsrn C..e m►i leterrasmeea iM ....Mier wieenw. w.ee. wow Atit Wed ~or t.l,ri. Comma ".oei i...rdw..rwn erobrua LINFORMACION In we rNMl dkee row* eweade Oat boat rw. rr,n.w loos'i rers.r 1aY.rAMMO *WIN .W W W.I.= air dermrwre Ye main.. Miler Meer .r,iMewfwlo owelo 1oMlorcaw CMrr4.ar.rwAtit nrarltaal UMW emr SOodder ad.r wr.errwwaMwarw ows loin Mors* Am..raltr. tap e r waste Ym mem. .raereare rrMar r.sss.ircodr.rco d In sleds Pen wewF.e re w.MMa a• rrww WHITE BACKGROUND WHITE/GREEN BACKGROUND, BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 2 4 RF EXPOSURE INFORMATION SIGN NOT TO SCALE WHITE TEXT 12 WHITE BACKGROUND RED TEXT NOTICE Beyond This Point you arc entering an area where RF Emissions trraycxcocd the FCC General Population Exposure Limits Follow ak povIod ups/end site guii ellnes for working m a RF environment! WHITE TEXT 8" SGNAGE NOTES: 1. SIGNS SHALL BE FABRICATED FROM CORROSION RESISTANT PRESSED METAL & PAINTED WITH LONG LASTING UV RESISTANT COATING. 2. SIGNS (EXCEPT WHERE NOTED OTHERWISE) SHALL BE MOUNTED TO THE TOWER, GATE & FENCE USING A MINIMUM OF 9 GAUGE ALUMINUM WIRE, HOG RINGS (FENCE) OR BRACKETS, WHERE NECESSARY. BRACKETS SHALL BE OF SIMILAR METAL AS THE STRUCTURE TO AVOID GALVANIC CORROSION. 3. ADDITIONAL E911 ADDRESS & FCC REGISTRATION SIGNS SHALL BE MOUNTED AT EACH ACCESS ROAD GATE LEADING TO THE COMPOUND AS WELL AS ON THE COMPOUND GATE ITSELF. 4. SIGNS NEED NOT BE PLACED IF ACCURATE AND APPROPRIATE SIGNAGE ALREADY EXISTS. INFORMATION Fsdsrei Communications Commission Tower Registration Number 12w '�11v t z v rowed in re rord.nc. M,tn F.d.nt Comnun;c.eem Camm,uidn Mire an unenne tower npstrenen 174OO 17 efel 0 12" GREEN BACKGROUND BLACK TEXT WHITE BACKGROUND WHITE/GREEN BACKGROUND, WHITE/BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 2 2 FCC REGISTRATION SIGN NOT TO SCALE BLUE BACKGROUND WHITE BACKGROUND BLACK TEXT WHITE/BLUE BACKGROUND, BLACK/WHITE LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 1 5 RF EXPOSURE NOTICE SIGN NOT TO SCALE BLACK TEXT g^ BLACK TEXT 12" ACAUTION� On this tower: Radio frequency flelds near some antennas may exceed FCC rules for human exposure. Personnel climbing this tower should be trained Ior working In radio Irequency environments and use a personal RF monkor If working near active antennas. J YELLOW BACKGROUND WHITE BACKGROUND YELLOW BACKGROUND WHITE/YELLOW BACKGROUND, BLACK LETTERING MOUNTING LOCATION: BASE OF TOWER QUANTITY: 1 6 RF EXPOSURE CAUTION SIGN NOT TO SCALE BLACK 8" GREEN TEXT BACKGROUND NFORMATION 12" ACTIVE ANTENNAS ARE MOUNTED ON THE OUTSIDE OF THIS BUILDING . BEHIND THIS PANEL - ON THIS STRUCTURE STAY BACK A MINIMUM OF 3 FEET FROM THESE ANTENNAS Contact AT&T Mobility at 800.63E-2622 and follow their instruCJons prior to performing any maintenance or repairs closer than 3 feet from the antennas. This is AT&T Mobility site WHITE BACKGROUND WHITE/GREEN BACKGROUND, BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 2 3 RF EXPOSURE INFORMATION SIGN NOT TO SCALE BLACK TEXT 12" 8" r Beyond this point: Radio frequency fields at this site eexceed the FCC rules for human xposure. Failure to obey ail posted srgns and sae guidelines for working in oar)," frequency environments could result in unlearn injury RED BACKGROUND WHITE BACKGROUND WHITE/RED BACKGROUND, BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 1 7 RF EXPOSURE WARNING SIGN NOT TO SCALE =rp B+T GRP C ITYSWITCH MOUNTAIN,LTD. MOUNTAIN LTD, WIRELES C1 1 U U z FA#10142260 O V O r- V PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUC11ON 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 Is"as `s.01 r SE 7. t, 2.1 ITIS A VIOLATION OF LAW F0 `ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SIGNAGE DETAILS SHEET NUMBER: c-11 CASE # 20-08-GCCP-05794 132151_NCC019_CD (11).dwg — Sheet:E-1 — User: mspeedie — NOTE: 1. ROUTE CONDUIT 36" FROM OBSTRUCTIONS. 2. HAND EXCAVATE WHERE EXISTING UNDERGROUND SERVICES EXIST. 3. ALL PULL STRINGS TO BE CONTINUOUS RUN OF MULE TAPE. LOCATE ALL UNDERGROUND UTILITY BORE PITS OUTSIDE OF 50' STREAM BUFFER (ZONE 2) UTILITY BORE PIT (TYP.) 50' STREAM BUFFER (ZONE 2) 30' STREAM BUFFER (ZONE 1) WETLAND LIMITS TOP OF BANK 30' STREAM BUFFER (ZONE 1) 50' STREAM BUFFER (ZONE 2) PROPOSED 10' WIDE UTILITIES EASEMENT PROPOSED 130' x 130' LEASE PROPOSED 220' SELF SUPPORT TOWER PROPOSED 12' DOUBLE SWING GATE PROPOSED H-FRAME / / / / EXISTING OVERHEAD POWER EXISTING POWER POLE PROPOSED 14' WIDE GRAVEL ACCESS ROAD PROPOSED 25' WIDE INGRESS/EGRESS EASEMENT PROP. UNDERGROUND ,e'ELEC.1 (BORE) �� PROP. UNDERGROUND PROP. UNDERGROUND TELCO 375 LF± PROPOSED 50' x 50' FENCED COMPOUND I LLCO 130 LF± (BORE) AMABU %9sPNqr RTpN p so' R/14o RACK PROPOSED / HANDHOLE PROPOSED ELEC & TELCO DEMARC T.B.D. PROP. UNDERGROUND ELEC. 420 LF± PROP. UNDERGROUND TELCO 420 LF± ELECTRICAL SITE PLAN SCALE: WETLAND LIMITS 0' 40' 80' 120' 1"=80' 160' O A. GENERAL NOTES: 1. IT IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO CONTACT THE SERVING POWER COMPANY AS SOON AS THE WORK IS SCHEDULED FOR THIS SITE. CONTRACTOR SHALL INFORM THEM OF THE CONDITIONS SPECIFIC TO THIS SITE AND COORDINATE THE PROPOSED ROUTING OF CONDUITS, TERMINATION OF CONDUITS, POWER (VOLTAGE AND KVA) REQUIRED AND SCHEDULED DATE OF ACTIVATION. 2. ROUTING OF UNDERGROUND UTILITIES IS APPROXIMATE; CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES AND SHALL BE EXTREMELY CAUTIOUS WHEN EXCAVATING TO AVOID DISRUPTION OF POWER OR TELEPHONE SERVICE OF OTHER TENANTS ON THE SITE. FAILURE TO OBSERVE THIS REQUIREMENT SHALL LEAVE THIS CONTRACTOR LIABLE FOR LOSS OF SERVICE (REVENUE) OF ANY SITE OCCUPANT. 3. CONTRACTOR SHALL PROVIDE ALL CONDUIT, WIREWAYS, CABINETS, ETC. AS REQUIRED BY SERVING ELECTRICAL UTILITY COMPANY. 4. DO NOT SCALE DRAWING; SITE VERIFY EXISTING CONDITIONS. 5. ELECTRICAL SERVICE SIZE IS NOMINAL FOR BIDDING PURPOSE ADJUST SIZE IF REQ'D BY A.H.J. OR TO MEET VOLTAGE DROP PERMITTED BY NFPA-70, ART 215. 6. PROVIDE PULLBOX AS SHOWN OR WHERE TOTAL CONDUIT BENDS EXCEED 360 AND/OR LENGTH OF CONDUIT EXCEED 200' (200' MAX PERMITTED BETWEEN PULLBOXES) LOCATE PULLBOXES TO PROVIDE UNIFORM PULLING TENSION. 7. THIS PROJECT REQUIRES EVALUATION FOR PROPOSED NEW SERVICE BY THE LOCAL POWER CO. PRIOR TO STARTING ANY WORK THE CONTRACTOR SHALL CONTACT THE POWER CO. AND COORDINATE THE POINT OF SERVICE DEMARCATION. CONTRACTOR SHALL INCLUDE ANY UTILITY COMPANY CHARGES FOR ESTABLISHING THESE SERVICES. 8. NEW TRENCH FOR THE BURIED CONDUIT AND GROUNDING CONDUCTORS SHALL BE WIDE ENOUGH TO PERMIT CONNECTIONS TO BE MADE AND INSPECTED BY AUTHORITIES HAVING JURISDICTION; BACKFILL SHALL BE NON -CORROSIVE, LOW RESISTIVITY, FREE OF DEBRIS AND STONES, TAMPED DOWN IN LAYERS NOT TO EXCEED 6" DEEP AND COMPACTED TO 95% OF ORIGINAL DENSITY. cr.LCALL NORTH CAROLINA ONE CALL n (800) 632-4949 ��I CALL 3 WORKING DAYS BEFORE YOU DIG! B+T GRP CITYSWIT CH MOUNTAIN? LTD. MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 Z E. O V O C7 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 It„ '`,%11• F�5 IpN�:\/.iA +..OQ.: 7 SE ft, INS B% `� ��. °"•°I..I;1IL i/5/�a IT IS A VIOLATION OF LAW FORA(NYPERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ELECTRICAL SITE PLAN SHEET NUMBER: E-1 CASE # 20-08-GCCP-05794 132151_NCC019_CD (11).dwg — Sheet:E-2 — User: mspeedie — PROPOSED 25' WIDE INGRESS/EGRESS / EASEMENT i / ////• / / PROPOSED 14' WIDE / GRAVEL ACCESS ROAD • < NNNNN\.N PROPOSED 10' WIDE UTILITIES EASEMENT PROPOSED PARKING AND TURNAROUND AREA PROPOSED FIBER PULL BOX 0 GRAVEL COMPOUND ELECTRICAL DETAIL PLAN SCALE: o' ///Too//// 10' 20' 30' PROPOSED AT&T 240 SQ FT LEASE AREA PROPOSED AT&T EQUIPMENT WIC PROPOSED GENERAC 20KW GENERATOR ON A 4'X5' PAD s. PROPOSED AT&T ICE BRIDGE PROP. UNDERGROUND ELEC. 28 LF± PROP. UNDERGROUND TELCO 28 LF± PROPOSED TOWER PROPOSED 50' x 50' FENCED COMPOUND 1"=20' 40' PROPOSED 130' x 130' LEASE AREA GENERAL NOTES: 1. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO CONTACT THE SERVING POWER COMPANY AS SOON AS THE WORK IS SCHEDULED FOR THIS SITE. CONTRACTOR SHALL INFORM THEM OF THE CONDITIONS SPECIFIC TO THIS SITE AND COORDINATE THE PROPOSED ROUTING OF CONDUITS, TERMINATION OF CONDUITS, POWER (VOLTAGE AND KVA) REQUIRED AND SCHEDULED DATE OF ACTIVATION. 2. ROUTING OF UNDERGROUND UTILITIES IS APPROXIMATE; CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES AND SHALL BE EXTREMELY CAUTIOUS WHEN EXCAVATING TO AVOID DISRUPTION OF POWER OR TELEPHONE SERVICE OF OTHER TENANTS ON THE SITE. FAILURE TO OBSERVE THIS REQUIREMENT SHALL LEAVE THIS CONTRACTOR LIABLE FOR LOSS OF SERVICE (REVENUE) OF ANY SITE OCCUPANT. 3. CONTRACTOR SHALL PROVIDE ALL CONDUIT, WIREWAYS, CABINETS, ETC. AS REQUIRED BY SERVING ELECTRICAL UTILITY COMPANY. 4. DO NOT SCALE DRAWING; SITE VERIFY EXISTING CONDITIONS. 5. ELECTRICAL SERVICE SIZE IS NOMINAL FOR BIDDING PURPOSE ADJUST SIZE IF REQ'D BY A.H.J. OR TO MEET VOLTAGE DROP PERMITTED BY NFPA-70, ART 215. 6. PROVIDE PULLBOX AS SHOWN OR WHERE TOTAL CONDUIT BENDS EXCEED 360 AND/OR LENGTH OF CONDUIT EXCEED 200' (200' MAX PERMITTED BETWEEN PULLBOXES) LOCATE PULLBOXES TO PROVIDE UNIFORM PULLING TENSION. 7. THIS PROJECT REQUIRES EVALUATION FOR PROPOSED NEW SERVICE BY THE LOCAL POWER CO. PRIOR TO STARTING ANY WORK THE CONTRACTOR SHALL CONTACT THE POWER CO. AND COORDINATE THE POINT OF SERVICE DEMARCATION. CONTRACTOR SHALL INCLUDE ANY UTILITY COMPANY CHARGES FOR ESTABLISHING THESE SERVICES. 8. NEW TRENCH FOR THE BURIED CONDUIT AND GROUNDING CONDUCTORS SHALL BE WIDE ENOUGH TO PERMIT CONNECTIONS TO BE MADE AND INSPECTED BY AUTHORITIES HAVING JURISDICTION; BACKFILL SHALL BE NON —CORROSIVE, LOW RESISTMTY, FREE OF DEBRIS AND STONES, TAMPED DOWN IN LAYERS NOT TO EXCEED 6' DEEP AND COMPACTED TO 95% OF ORIGINAL DENSITY. NOTE: 1. ROUTE CONDUIT 36" FROM OBSTRUCTIONS. 2. HAND EXCAVATE WHERE EXISTING UNDERGROUND SERVICES EXIST. 3. ALL PULL STRINGS TO BE CONTINUOUS RUN OF MULE TAPE. CALL NORTH CAROLINA ONE CALL n (800) 632-4949 ��I CALL 3 WORKING DAYS BEFORE YOU DIG! =IF B+T GRP C ITYSWITCH Alt MOUNTAIN?=v. MOUNTAIN LTD, WIRELES G1 1 U U z FA#10142260 Z p O V O C7 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 Pt, 0,1\1• Y,' ,`, CAR ',`',-, s� Q r �. d SE �. -4115, 14',,11f 1111 ....5i tit IT IS A VIOLATION OF LAW FG ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ELECTRICAL DETAIL PLAN SHEET NUMBER: E-2 CASE # 20-08-GCCP-05794 N 0 132151_NCC019_CD (11).dwg — Sheet:E-3 — User: mspeedie — Oct ELECTRICAL NOTES: SCOPE: 1. PROVIDE LABOR, MATERIAL, INSPECTION, AND TESTING TO PROVIDE COMPLIANCE FOR ELECTRIC, TELEPHONE, AND GROUNDING/LIGHTING SYSTEMS. CODES: 1. THE INSTALLATION SHALL COMPLY WITH APPUCABLE NOT LIMITED TO THE LATEST ADOPTED EDITION OF: A. THE NATIONAL ELECTRICAL SAFETY CODE B. THE NATIONAL ELECTRIC CODE - NFPA-70 C. REGULATIONS OF THE SERVING UTILITY COMPANY 2. PERMITS REQUIRED SHALL BE OBTAINED BY THE CO 3. AFTER COMPLETION AND FINAL INSPECTION OF THE CERTIFICATE OF COMPLETION AND APPROVAL. LAWS AND CODES. THESE INCLUDE BUT ARE D. LOCAL AND STATE AMENDMENTS E. THE INTERNATIONAL ELECTRIC CODE- IEC (WHERE APPUCABLE) NTRACTOR. WORK, THE OWNER SHALL BE FURNISHED A TESTING. 1. UPON COMPLETION OF THE INSTALLATION, OPERATE AND ADJUST THE EQUIPMENT AND SYSTEMS TO MEET SPECIFIED PERFORMANCE REQUIREMENTS. THE TESTING SHALL BE DONE BY QUALIFIED PERSONNEL. GUARANTEE: 1. IN ADDITION TO THE GUARANTEE OF THE EQUIPMENT BY THE MANUFACTURER, EACH PIECE OF EQUIPMENT SPECIFIED HEREIN SHALL ALSO BE GUARANTEED FOR DEFECTS OF MATERIAL OR WORKMANSHIP OCCURRING DURING A PERIOD OF ONE (1) YEAR FROM FINAL ACCEPTANCE OF THE WORK BY THE OWNER AND WITHOUT EXPENSE TO THE OWNER. 2. THE WARRANTEE CERTIFICATES & GUARANTEES FURNISHED BY THE MANUFACTURERS SHALL BE TURNED OVER TO THE OWNER. UTILITY CO-ORDINATION: 1. CONTRACTOR SHALL COORDINATE WORK WITH THE POWER AND TELEPHONE COMPANIES AND SHALL COMPLY WITH THE SERVICE REQUIREMENTS OF EACH UTILITY COMPANY. EXAMINATION OF SITE: 1. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL VISIT THE SITE OF THE JOB AND SHALL FAMILIARIZE HIMSELF WITH THE CONDITIONS AFFECTING THE PROPOSED ELECTRICAL INSTALLATION AND SHALL MAKE PROVISIONS AS TO THE COST THEREOF. FAILURE TO COMPLY WITH THE INTENT OF THIS SECTION WILL IN NO WAY RELIEVE THE CONTRACTOR OF PERFORMING THE WORK NECESSARY FOR A COMPLETE AND WORKING ST51EM OR SYSTEMS. CUTTING. PATCHING AND EXCAVATION: 1. COORDINATION OF SLEEVES, CHASES. ETC., BETWEEN SUBCONTRACTORS WILL BE REQUIRED PRIOR TO THE CONSTRUCTION OF ANY PORTION OF THE WORK. CUTTING AND PATCHING OF WALLS, PARTITIONS, FLOORS, AND CHASES IN CONCRETE, WOOD, STEEL OR MASONRY SHALL BE DONE AS PROVIDED ON THE DRAWINGS. 2. NECESSARY EXCAVATIONS AND BACKFILLING INCIDENTAL TO THE ELECTRICAL WORK SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWING. 3. SEAL PENETRATIONS THROUGH RATED WALLS, FLOORS. ETC.. WITH APPROVED METHOD AS LISTED BY UL. RACEWAYS / CONDUITS GENERAL: 1. CONDUCTORS SHALL BE INSTALLED IN LISTED RACEWAYS, CONDUIT SHALL BE RIGID STEEL, EMT, SCH40 PVC, OR SCH80 PVC AS INDICATED ON THE DRAWINGS. THE RACEWAY SYSTEM SHALL BE COMPLETE BEFORE INSTALLING CONDUCTORS. 2. EXTERIOR RACEWAYS AND GROUNDING SLEEVES SHALL BE SEALED AT POINTS OF ENTRANCE AND EXIT. THE RACEWAY SYSTEM SHALL BE BONDED PER NEC. EXTERIOR CONDUIT: 1. EXPOSED CONDUIT SHALL BE NEATLY INSTALLED AND RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL ELEMENTS. SUPPORTS AND MOUNTING HARDWARE SHALL BE HOT DIPPED GALVANIZED STEEL. 2. WHERE INSTALLED ON EXTERIOR STRUCTURES OR EXPOSED TO DAMAGE. THE CONDUIT SHALL BE RIGID STEEL. 3. UNDERGROUND CONDUITS SHALL BE RIGID STEEL, SCH40 PVC. OR SCH80 PVC AS INDICATE ON THE DRAWINGS. 4. BURIAL DEPTH OF CONDUITS SHALL BE AS REQUIRED BY CODE FOR EACH SPECIFIC CONDUIT TYPE AND APPLICATION BUT SHALL NOT BE LESS THAN THE FROST DEPTH AT THE SITE. 5. CONDUIT ROUTES ARE SCHEMATIC. CONTRACTOR SHALL FIELD VERIFY ROUTES BEFORE BID. COORDINATE ROUTE WITH WIRELESS CARRIER AND/OR BUILDING OWNER. INTERIOR CONDUIT: 1. CONCEALED CONDUIT IN WALLS OR INTERIOR SPACES ABOVE GRADE MAY BE EMT. 2. CONDUIT RUNS SHALL USE APPROVED COUPLINGS AND CONNECTORS. PROVIDE INSULATED BUSHING FOR ALL CONDUIT TERMINATIONS. CONDUIT RUNS IN A WET LOCATION SHALL HAVE WATERPROOF FITTINGS. 3. PROVIDE SUPPORTS FOR CONDUITS IN ACCORDANCE WITH NEC REQUIREMENTS. CONDUITS SHALL BE SIZED AS REQUIRED BY NEC. EQUIPMENT. 1. DISCONNECT SWITCHES SHALL BE SERVICE ENTRANCE RATED, HEAVY DUTY TYPE. 2. CONTRACTOR SHALL VERIFY MAXIMUM AVAILABLE FAULT CURRENT AND COORDINATE INSTALLATION WITH THE LOCAL UTILITY BEFORE STARTING WORK. CONTRACTOR WILL VERIFY THAT EXISTING CIRCUIT BREAKERS ARE RATED FOR MORE THAN AVAILABLE FAULT CURRENT AND REPLACE AS NECESSARY. 3. NEW CIRCUIT BREAKERS SHALL BE RATED TO WITHSTAND THE MAXIMUM AVAILABLE FAULT CURRENT AS DETERMINED BY THE LOCAL UTILITY. CONDUCTORS: 1. FURNISH AND INSTALL CONDUCTORS SPECIFIED IN THE DRAWINGS. CONDUCTORS SHALL BE COPPER AND SHALL HAVE TYPE THWN (MIN) (75'C) INSULATION, RATED FOR 600 VOLTS. 2. THE USE OF ALUMINUM CONDUCTORS SHALL BE LIMITED TO THE SERVICE FEEDERS INSTALLED BY THE UTILITY. 3. CONDUCTORS SHALL BE PROVIDED AND INSTALLED AS FOLLOWS: A. MINIMUM WIRE SIZE SHALL BE #12 AWG. B. CONDUCTORS SIZE #8 AND LARGER SHALL BE STRANDED. CONDUCTORS SIZED #10 AND #12 MAY BE SOLID OR STRANDED. C. CONNECTION FOR #10 AWG #12 AWG SHALL BE BY TWISTING TIGHT AND ISTALLING INSULATED PRESSURE OR WIRE NUT CONNECTIONS. D. CONNECTION FOR #8 AWG AND LARGER SHALL BE BY USE OF STEEL CRIMP -ON SLEEVES WITH NYLON INSULATOR. 4. CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC STANDARDS. UL COMPLIANCE: 1. ELECTRICAL MATERIALS, DEVICES, CONDUCTORS, APPLIANCES, AND EQUIPMENT SHALL BE LABELED/LISTED BY UL OR ACCEPTED BY JURISDICTION (LE., LOCAL COUNTY OR STATE) APPROVED THIRD PARTY TESTING AGENCY. GROUNDING: 1. ELECTRICAL NEUTRALS, RACEWAYS AND NON -CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT AND ASSOCIATED ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH NEC ARTICLE 250. THIS SHALL INCLUDE NEUTRAL CONDUCTORS, CONDUITS, SUPPORTS, CABINETS, BOXES, GROUND BUSSES, ETC. THE NEUTRAL CONDUCTOR FOR EACH SYSTEM SHALL BE GROUNDED AT A SINGLE POINT. 2. PROVIDE GROUND CONDUCTOR IN RACEWAYS PER NEC. 3. PROVIDED BONDING AND GROUND TO MEET NFPA 780- LIGHTING PROTECTION " AS A MINIMUM. 4. PROVIDE GROUNDING SYSTEM AS INDICATED ON THE DRAWINGS, AS REQUIRED BY THE NATIONAL ELECTRIC CODE, RADIO EQUIPMENT MANUFACTURES. AND MOTOROLA R56 (AS APPUCABLE). ABBREVIATIONS AND LEGEND A AFG ATS AWG BCW BFG BKR C CKT DISC EGR EMT FSC GEN GPS GRD IGB IGR KW NEC PCS PH PNL AMPERE ABOVE FINISHED GRADE AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE BARE COPPER WIRE BELOW FINISHED GRADE BREAKER CONDUIT CIRCUIT DISCONNECT EXTERNAL GROUNDING RING ELECTRIC METALLIC TUBING FLEXIBLE STEEL CONDUIT GENERATOR GLOBAL POSITIONING SYSTEM GROUND ISOLATED GROUND BAR INTERIOR GROUND BAR KILOWATTS NATIONAL ELECTRIC CODE PERSONAL COMMUNICATION SYSTEM PHASE PANEL PHLBD PVC RGS SW TGB UL V W XFMR XMTR - PANELBOARD - RIDGID NON-METALLIC CONDUIT - RIGID GALVANIZED STEEL CONDUIT - SWITCH - TOWER GROUND BAR - UNDERWRITERS LABORATORIES - VOLTAGE - WATTS - TRANSFORMER - TRANSMITTER P F UNDERGROUND ELECTRICAL CONDUIT UNDERGROUND FIBER CONDUIT KILOWATT-HOUR METER UNDERGROUND BONDING AND GROUNDING CONDUCTOR GROUND ROD COMPRESSION TYPE CONNECTIONS EXOTHERMIC TYPE CONNECTIONS GROUND ROD WITH INSPECTION WELL =IF B+T GRP C ITYSWTCH 4 A .ODUTAIN? LTD. MOUNTAIN LTD, WIRELES FA#10142260 Z E. 0 V 0 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 ,<;%%%s; e•NQ F1~5 to;i7, /r .I: It SE i� R IS A VIOLATION OF LAW FORANY PERSON, UNLESS �IHEY ARE ACTING UNDER THE DIRECTION OF A LICENSED IPROFLSSIONRL ENGINIER, TO ALTER THIS DOCUMENT. ELECTRICAL NOTES SHEET NUMBER: E-3 CASE # 20-08-GCCP-05794 0 0 132151_NCC019_CD (11).dwg — Sheet:E-4 — User: mspeedie — NOTES: 1. CONTRACTOR TO FIELD LOCATE THE METER PEDESTAL AS SHOWN ON SITE PLAN. INSTALL THE METER PEDESTAL NEAR THE PERIMETER OF THE FENCED COMPOUND WITH THE METERS FACING AS SHOWN. 2. THE CONTRACTOR SHALL COORDINATE THE THE LOCAL UTILITY COMPANY FOR THE CONDUIT RUN TO THE MAIN SERVICE CONNECTION OR TRANSFORMER. 3. THE CONTRACTOR SHALL COORDINATE THE THE LOCAL UTILITY COMPANY FOR GROUND ROD REQUIREMENTS. IF REQUIRED, THE CONTRACTOR SHALL ORDER AND PAY FOR NECESSARY GROUND TESTS. 4. SUPPORT POST AND UNISTRUT SHALL BE GALVANIZED. PIPE CLAMPS AND HARDWARE SHALL BE GALVANIZED OR STAINLESS STEEL. 5. ADJUSTMENTS TO THE METER PEDESTAL DESIGN MAY BE REQUIRED DEPENDING ON THE EXACT METER PANEL INSTALLED. CONTRACTOR SHALL FIELD COORDINATE ADJUSTMENTS AND INFORM THE ENGINEER IF ANY UNUSUAL CONDITIONS ARE FOUND TO EXIST. 6'-6" FIELD VERIFY i0 m H-FRAME LENGTH TO BE DETERMINED BY AREA CONSTRUCTION MANAGER LABEL METER BASE PER LOCAL `UTILITY REQUIREMENTS 000000000000 d O V 4, uu TO GROUND ROD -7 1'-0" DIA. 0 00000000000000000000� 00 CITYSWITCH LIGHTING \ETER KWH a WATER TIGHT ENDCAP (TYP.) 3" DIA. (3.5" O.D.) RGP STANDARD UNISTRUT END 7CAPS (TYP.) 1-5/8" P1000 UNISTRUT ATTACHED WITH STANDARD PIPE CLAMPS (TYP.) u H-FRAME LENGTH TO BE DETERMINED BY AREA CONSTRUCTION MANAGER 100A LOAD CENTER (IF REQUIRED) 4-GANG, 800A RATED 240/120-10-3W, NEMA 3R, MULTI -METER CENTER ON NEW SERVICE H-FRAME. COORDINATE WITH UTILITY COMPANY FOR NEW 200; 120/240-10-3W SERVICE FOR AT&T, D= 00000000000000000000dJ AND FOR NEW 100A 120/240-10-3W SERVICE FOR UNITI TOWERS PART #0012L125GRB SLOPE CONCRETE AWAY FROM POST (TYP.) III I. 11,1 IP II� IIFIII • jet i1 3" CONDUIT FOR U POWER CON DUITS TO MAIN SERVICE UTILITY H-FRAME DETAIL (GANG METER SIDE) • SCALE: N.T.S. FINISHED GRADE CONCRETE POST FOOTING (300 PSI MIN.) TOWER LIGHT CONTROLLER (FLASH CERTIFIED) 0U� 1/ 6 CONDUIT FROM METER 48"x48" MULTI -TENANT TELCO CABINET WITH PLYWOOD BACKBOARD GROUND BUS BAR PROPOSED NOT INSTALLED 7BTS GS TO INSTALL 2" CONDUIT FROM H-FRAME TO NEAREST TOWER LEG/WAVEGUIDE LADDER (WITH WEATHER HEADS ON EACH END OF CONDUIT) UTILITY H-FRAME DETAIL SCALE: N.T.S. 3" CONDUIT FOR POWER CONDUITS TO MAIN SERVICE WATER TIGHT ENDCAP (TYP.) STANDARD UNISTRUT END CAPS (TYP.) 1-5/8" P1000 UNISTRUT ATTACHED WITH STANDARD PIPE CLAMPS (TYP.) 3" DIA. (3.5" O.D.) RGP SLOPE CONCRETE AWAY FROM POST (TYP.) FINISHED GRADE CONCRETE POST FOOTING (300 PSI MIN.) =IF B+T GRP C ITYSWIT C H M.OUHTAIN LW. MOUNTAIN LTD, WIRELES 1 u uu H FA#10142260 Z O V PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 R IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. UTILITY H-FRAME DETAILS SHEET NUMBER: E-4 CASE # 20-08-GCCP-05794 51_NCC019_CD (11).dwg — Sheet:E-5 — User: mspeedie — DEPTH PER MIN NOTES: SEE NOTE 2 SLOPE TO SUIT SOIL CONDITION IN ACCORDANCE WITH LOCAL REGULATIONS BACKFILL UTILITY WARNING TAPE SAND BEDDING (1) 4" SCH 40 PVC POWER CONDUIT (1) 4" SCH 40 PVC TELCO CONDUIT (3) 1-1/4" INNERDUL I S CONTRACTOR SHALL RESTORE THE TRENCH TO ITS ORIGINAL CONDITIONS BY EITHER SEEDING OR SODDING GRASS AREA, OR REPLACING ASPHALT OR CONCRETE AREAS TO ITS ORIGINAL CROSS SECTION. 0 TRENCH DETAIL FOR BURIED CONDUIT SCALE: N.T.S. FINISHED GRADE, OR GROUND COVER MATCH SLOPE AND THICKNESS OF EXISTING 0 UNEXCAVATED (1) 4" SCH 40 PVC POWER CONDUIT (1) 4" SCH 40 PVC TELCO CONDUIT (3) 1-1/4" INNERDUL IS UTILITY BORE DETAIL SCALE: N.T.S. HANDHOLE — 30"x48"x36" I-5K RATING — BOX & 2 Pc SPLIT COVER EMS MARKER ?/2 1131 5.3. FLAT WASHER a 2 PLACES �_ _ /�!/ SKID RFS1S1'ANT SURFACE MS-86 — 24 [610] I. CABLE RACK 6 PLACES (2 EACH SIDE) 1/2-13 (INC LIFTING BOLTS 4 PLACES .36 r0l 4900JI1 1669 I I i000° Its PC3048B708 TERMINATOR FOR 4" [1021 CONDUIT 4 PIACFS (2 FACH END) HANDHOLE DETAIL SCALE: N.T.S. 1/2-13 UNC X 4 11021 LG. S_S HEX HEAD CAPTIVE BOLT 2 PLACES ?/8 [161 THRU HOLE W/? 1/4 [321 X 1/2 1121 DEEP CHORE 2 PLACES QUAZITE LOGO 1 1251 X 4 [1021 PULL SLOT W/'/4 10] CENTER PIN 4 PLACES POLYMER TONGUE do GROOVE PG304811634YS 1/2-13 UNC SELF ALIGNING, REPLACEABLE S.S. EZ-NUT 2 PLACES NOTES= 1. CUSTOMER IS AT&T 2. THIS ASSEMBLY IS RATED FOR NON- Ok34BERATE vBHICULAR TRAFFIC WITH A DESIGN I.OAn OF 15.000 I.R.S (06.720 NJ OVER A 10 [254J X 20 [509j AREA AND MIST PASS A MINIMUM STATIC TEST LOAD 45.146 LBS. [200,800 NI. 3. DIMENSIONS IN BRACKETS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. 5/8 PULLING EYE 1500,j [6672N] MAX PULL OUT (1 EACH END) cnNSTRIIf TinN NfTF5; 1.DEPTH OF EXCAVATION 15 4' DEEPER THAN THE ULPTH OF THE HANOHOLE. 2.USE BASE GRAVEL NO LARGER THAN 1/2 ' 3.PLACE HANDHOLE WITH COVER IN PLACE. 4.SET HANOHOIF FLUSH WITH GRADE THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING ON THE WORK CONTAINED WITHIN THIS DESIGN PACKAGE. DISCREPANCIES AND OMISSIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. -p B+T GRP C ITYSWIT C H it .ODUHTAIN LW. MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 Z p O V PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION s L ►yti+rS� Fi IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ELECTRICAL DETAILS SHEET NUMBER: E-5 CASE # 20-08-GCCP-05794 0 132151_NCC019_CD (11).dwg — Sheet:E-5 — User: mspeedie — Oct EXISTING TELCO/FIBER SERVICE FROM LOCAL DEMARCATION POINT TELCO BACKBOARD ALARM BLOCKS) 0 PROPOSED CIRCUIT BREAKER TO FEED AT&T (SERVICE DISCONNECT) 200A, 240V, 2 POLE 00 El ' TVSS� �T C2 AWG—J_ SMGB EXISTING 200A. 120/240V. 1 PHASE SERVICE FROM UTILITY COMPANY 0 AT&T I LILY METER, 200A. 120/240V, 1 PHASE. 3W SHELTER DISCONNECT. 200A, 120/240V, 10, Og 3W (WHERE REQUIRED) EXISTING GROUND ELECTRODE O SHELTER PANEL 'LCP', 200A, O 120/240VAC, 30 POLE, 10 KAIC, BOLT ON BREAKERS AUTOMATIC TRANSFER SWITCH, 200A, 120/240V, 2P. 3W O —0 0 ZUKW INUUSIKUIL UIt tL GENERATOR BY GENERAL MODEL: G007098-0 (STEEL) POWER RATING: 120/240 VAC 0 1.0pf-20kW- 100/ 2P 83A O DC POWER PLANT (7) 0 PER RECTIFIER WITH (1) j8 GROUND FROM AC O PANEL TO DC POWER PLANT CABLE AND CONDUIT SCHEDULE MARK CONDUIT WIRES EACH CONDUIT EQUIPMENT FROM TO REMARKS QTY. SIZE TYPE QTY. SIZE GROUND SIZE VOLTS IMPS SUB. CAT. 01 2' PVC 3 /3/0 /4 240 200 AC POWER SVC DISC PNL POWER TO SHELTER. SEE NOTE 8 0 1 0.-4" PVC WITH (3 1 INNEFOUCTS — (1) 25 PR CAT se SHIELDED — N2 FOR DC POWER FOR -- -- 1ELCO DEMARC FLX12 25 PAIR AND 24 VDC POWER FOR FIBER 3 1 2-1/2' PVC 38 /8 —48 400 DC POWER GEN DISC DC POWER PLANT GENERATOR POWER TO SHELTER, NOTE 8 4 1 1' PVC (7) #14 AND BELDEN -- -- -- CNTL PNL ATS GENERATOR MAR11 CONTROL GENERAL NOTES: 1. CONTRACTOR SHALL COORDINATE INCOMING SERVICES WITH LOCAL UTILITIES PRIOR TO TRENCHING. 2. ALL CONDUCTORS SHALL BE COPPER. 75*C RATED (MIN.) AND CONDUCTOR INSULATION SHALL BE THWN OR THHN. 3. ALL TERMINATIONS SHALL BE LISTED AND IDENTIFIED FOR USE WITH 75* C RATED CONDUCTORS OPERATING AT 75*. 4. GROUND FAULT PROTECTION REQUIRED FOR UTILITY RECEPTACLES. 5. SERVICE NEUTRAL SHALL BE GROUNDED AT ONE LOCATION ONLY. 6. WHITE/NEUTRAL, GREEN/GROUND SHALL BE MAINTAINED THOUGH OUT THE SITE ELECTRICAL SYSTEM (TAPE WILL NOT BE ACCEPTABLE). 7. EQUIPMENT LOCATED OUTSIDE OR EXPOSED TO MOISTURE SHALL BE NEMA 3R RATED. 8. CONTRACTOR SHALL USE RIGID METAL CONDUIT (RMC) OR INTERMEDIATE METAL CONDUIT (IMC) WHERE POWER CONDUITS ARE EXPOSED. OTHERWISE, ALL CONDUITS SHALL BE SCHEDULE 80 PVC. UNLESS OTHERWISE NOTED. 9. ALL NEWLY INSTALLED EQUIPMENT SHALL BE RATED AT 10K AIC MINIMUM, HIGHER RATINGS SHALL BE REQUIRED WHERE AVAILABLE FAULT CURRENT EXCEEDS THIS VALUE. EXACT FAULT CURRENT AVAILABLE SHALL BE COORDINATED WITH LOCAL UTILITY BASED ON EXACT CONDITIONS (TRANSFORMER SIZE, PERCENT IMPEDANCE, LENGTH OF CONDUCTORS, ETC.). 0 ELECTRICAL RISER DIAGRAM NOTES BY SYMBOL 0 CONTRACTOR SHALL FURNISH AND INSTALL POWER CONDUCTORS FROM METER CENTER TO SHELTER. METER WILL BE FURNISHED AND INSTALLED BY LOCAL UTILITY COMPANY. 0 CONTRACTOR SHALL PROVIDE AND INSTALL CIRCUIT BREAKER IN METER CENTER TO FEED AT&T SHELTER. CIRCUIT BREAKER SHALL BE 200A, 240V, 2 POLL TYP AND AIC RATING SHALL MATCH EXISTING. O3 CONTRACTOR SHALL PROVIDE ALL CIRCUIT BREAKERS REQUIRED TO FEED AT&T EQUIPMENT. CONTRACTOR SHALL LABEL ALL CIRCUIT BREAKERS WITH RESPECT TO SHAT THEY FEED. O LOAD CENTER IS EQUIPPED WITH TRANSFER SWITCH FOR GENERATOR CONNECTIONS. BREAKERS ARE INTERLOCKED TO ALLOW ONLY 1 BREAKER CLOSED AT ANY GIVEN TIME. p. CONTRACTOR SHALL PROVIDE AND INSTALL NAMEPLATE ON METER TO INDICATE 'AT&T. NAMEPLATES SHALL BE PHENOLIC, WHITE LETTERS ON BLACK BACKGROUND. b 6 6 CONTRACTOR SHALL BOND NEUTRAL TO GROUND AT ONE LOCATION ONLY PER NEC 250 AND LOCAL CODE REQUIREMENTS. DO NOT BOND GENERATOR NEUTRAL TO GROUND OR GENERATOR FRAME. GENERATOR NEUTRAL IS BONDED TO SERVICE ENTRANCE NEUTRAL BOND VIA SOURLY GROUNDED ATS (OPEN TRANSITION, FLOATING NEUTRAL AT GENERATOR. DISCONNECT IS FURNISHED WITH SHELTER. ON SITES WHERE SERVICE IS OBTAINED FROM AN EXISTING SOURCE (METER CENTER), OR SERVICE DISCONNECT IS LOCATED ON EQUIPMENT RACK, SHELTER DISCONNECT MAY BE OMITTED. SCALE: N.T.S. =IF B+T GRP C ITYSWITCH MOUNTAIN? LTD, MOUNTAIN LTD, WIRELES 1 U U z FA#10142260 E. Z p 0 V 0 C7 0 0 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 11 . .Z '` "s ", Q r� SE i� . ,e"..IIf1111 61 ..5/ FJ /PERSON, IT IS A VIOLATION OF LAW FORANY UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ELECTRICAL RISER DIAGRAM SHEET NUMBER: E-6 CASE # 20-08-GCCP-05794 132151_NCC019_CD (11).dwg — Sheet:E-7 — User: mspeedie — Oct 0 PANEL SCHEDULE IMREPOS SZE VOLT AMPS LOAD POLES AMP L1 L2 AMP POLES LOAD VOLT AMPS SIZE POS L1 L L2 L1 L2 1 #10 2000 RECTIFIER #1 2 30A I 20A 1 EXT. GFCI CUTLETS 180 #12 2 — 3 2000 30A 2 RECTIFIER #2 2000 #10 4 5 #10 2000 RECTIFIER #3 2 30A 2000 6 — 7 2000 30A 2 RECTIFIER #4 2000 #10 8 9 #10 2000 RECTIFIER #5 2 30A 2000 10 — 11 •---___, 2000 30A 2 RECTIFIER 2000 #10 12 13 2000 14 17 16 17 18 20 21 Fr19 22 23 24 25 #12 3504 1 TON AC UNIT 2 20A Prir 26 — 27 3504 20A 1 EXT. FLOOD UGHTS 70 #12 28 29 #12 480 APPLIANCE OUTLETS 1 20A 30 9984 9504 :SUB TOTAL VOLT AMPS :SUB TOTAL VOLT AMPS 6180 6070 16,164 15.574 L2 VOLT AMPS 31,738 TOTAL VOLT AMPS 132.25 TOTAL AMPS 165.3 AMPS x 125X 181.9 x 110X 125X AT&T ELECTRICAL PANEL SCHEDULE SCALE: N.T.S. B+T GRP C ITYSWITCH 4 MOUNTAIN? LTD. MOUNTAIN LTD, WIRELES FA#10142260 E. Z p O V PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 11 �`�L\1 „►I +4,, v r ', ,.., FPS IpN�:�/re. SE `` .P/mil I N S r V ti '.`` e"I,►I f 1111 1ii11 / IT IS A VIOLATION OF LAW FDe-ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. AT&T ELECTRICAL PANEL SCHEDULE SHEET NUMBER: E-7 CASE # 20-08-GCCP-05794 N 0 N User: mspeedie 132151_NCC019_CD (11).dwg — Sheet:G-1 PROPOSED FENCE AND GATE GROUNDING (SEE SHEET G-3 FOR DETAILS) PROP. AT&T ICE BRIDGE EQUIPMENT PAD GROUND RING PROPOSED AT&T EQUIPMENT WIC CONNECT TO TOWER GROUND RING PROPOSED TOWER GROUND RING PROPOSED 50' x 50' FENCED COMPOUND PROPOSED TOWER 0 GROUNDING PLAN SCALE: 0' 10' 20' 30' 1 "=20' 40' GROUNDING NOTES: 1. GROUNDING ELECTRODES SHALL BE CONNECTED IN A RING USING @ 2 AWG BARE TINNED COPPER WIRE. THE TOP OF THE GROUND RODS AND THE RING CONDUCTOR SHALL BE 2' BELOW FINISHED GRADE. GROUNDING ELECTRODES SHALL BE DRIVEN ON (10'-0" CENTERS MIN - 15'-0" MAX). 2. BONDING OF THE GROUNDED CONDUCTOR (NEUTRAL) AND THE GROUNDING CONDUCTOR SHALL BE AT THE SERVICE DISCONNECTING MEANS/BONDING JUMPER SHALL BE INSTALLED PER NEC ARTICLE 250.30. 3. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER WHEN THE GROUNDING SYSTEM IS COMPLETE. THE CONSTRUCTION MANAGER SHALL INSPECT THE GROUNDING SYSTEM PRIOR TO BACKFILLING. # GROUNDING NOTES OCOPPER O5/8"x10' O OGROUND O O#2 OGROUND O CLAD GROUND ROD (TYP) 5/8"x10' LONG ROD W/ GROUND INSPECTION TEST WELL (TYP) #2 SOLID TINNED COPPER GROUND WIRE LEAD FROM FENCE TO PROPOSED TOWER GROUND RING BOTTOM OF TOWER GROUND BAR TINNED INSULATED LEAD TO TOWER STEEL LEAD TO H-FRAME AND ALL EQUIPMENT ON H-FRAME (TYP) MASTER GROUND BAR GROUNDING LEGEND - 5/8"x10'-0" COPPER CLAD GROUND ROD WITH INSPECTION WELL (FIELD VERIFY LOCATION WITH MANAGER) ®-5/8"x10'-0" COPPER CLAD GROUND ROD AT 15.-0" MAX. CENTERS • -MECHANICAL CONNECTION • -EXOTHERMIC WELD (CAD WELD) - #2 SOLID COPPER TINNED WIRE UNLESS NOTED OTHERWISE THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING ON THE WORK CONTAINED WITHIN THIS DESIGN PACKAGE. DISCREPANCIES AND OMISSIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. CALL NORTH CAROLINA ONE CALL( r► I (800) 632-4949� CALL 3 WORKING DAYS BEFORE YOU DIG! =IF B+T GRP C ITYSWITCH APIE, MOUNTAIN? LTD. MOUNTAIN LTD, WIRELES U U7 FA#10142260 O V PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 ,<;%%%s;A� , F E.S I0;17, 4•.�: :.' r. Q r SE i -7f >. INE:r �. °"••,,,„,T 6Lr15/ IT IS A VIOLATION OF LAW ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. GROUNDING PLAN SHEET NUMBER: G-1 CASE # 20-08-GCCP-05794 N 0 N 132151_NCC019_CD (11).dwg — Sheet:G-2 — User: mspeedie — GROUNDING NOTES: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 2. ALL GROUNDING DEVICES SHALL BE U.L APPROVED OR LISTED FOR THEIR INTENDED USE. 3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE. 4. GROUNDING CONNECTIONS TO GROUND RODS, GROUND RING WIRE, TOWER BASE AND FENCE POSTS SHALL BE EXOTHERMIC ("CADWELDS") UNLESS NOTED OTHERWISE. CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZING PAINT. 5. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO -HOLE BRASS MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING SCREW SET) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING. 6. GROUND COAXIAL CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS. 7. ROUTE GROUNDING CONDUCTORS THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 12" RADIUS. 8. INSTALL #2 AWG GREEN -INSULATED STRANDED WIRE FOR ABOVE GRADE GROUNDING AND #2 BARE TINNED COPPER WIRE FOR BELOW GRADE GROUNDING UNLESS OTHERWISE NOTED. 9. REFER TO GROUNDING PLAN FOR GROUND BAR LOCATIONS. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC TYPE ("CADWELDS") TO ANTENNA MOUNTS AND GROUND RING. REMAINING GROUNDING CONNECTIONS SHALL BE COMPRESSION FITTINGS. CONNECTIONS TO GROUND BARS SHALL BE MADE WITH TWO -HOLE LUGS. 10. THE GROUND ELECTRODE STSILM SHALL CONSIST OF DRIVEN GROUND RODS POSITION ACCORDING TO GROUNDING PLAN. THE GROUND RODS SHALL BE 5/8"X10'-0" COPPER CLAD STEEL INTERCONNECTED WITH #2 BARE TINNED COPPER WIRE BURIED 36" BELOW GRADE. BURY GROUND RODS A MAXIMUM OF 15' APART, AND A MINIMUM OF 8' APART. 11. IF ROCK IS ENCOUNTERED GROUND RODS SHALL BE PLACED AT AN OBLIQUE ANGLE NOT TO EXCEED 45'. 12. EXOTHERMIC WELDS SHALL BE MADE IN ACCORDANCE WITH ERICO PRODUCTS BULLETIN A -AT. 13. CONSTRUCTION OF GROUND RING AND CONNECTIONS TO EXISTING GROUND RING SYSTEM SHALL BE DOCUMENTED WITH PHOTOGRAPHS PRIOR TO BACKFILUNG SITE. PROVIDE PHOTOS TO THE AT&T CONSTRUCTION MANAGER. 14. ALL GROUND LEADS EXCEPT THOSE TO THE EQUIPMENT ARE TO BE #2 BARE TINNED COPPER WIRE. ALL EXTERIOR GROUND BARS TINNED COPPER. 15. PRIOR TO INSTAWNG LUGS ON GROUND WIRES, APPLY THOMAS & BETTS KOPR-SHIELD (TM OF JET LUBE INC.). PRIOR TO BOLTING GROUND WIRE LUGS TO GROUND BARS, APPLY KOPR-SHIELD OR EQUAL. 16. ENGAGE AN INDEPENDENT ELECTRICAL TESTING FIRM TO TEST AND VERIFY THAT IMPEDANCE DOES NOT EXCEED FIVE OHMS TO GROUND BY MEANS OF "FALL OF POTENTIAL TEST". TEST SHALL BE WITNESSED BY A METROPCS REPRESENTATIVE, AND RECORDED ON THE "GROUND RESISTANCE TEST" FORM. 17. WHERE BARE COPPER GROUND WIRES ARE ROUTED FROM ANY CONNECTION ABOVE GRADE TO GROUND RING, INSTALL WIRE IN 3/4" PVC SLEEVE, FROM 1' BELOW GRADE AND SEAL TOP WITH SILICONE MATERIAL. 18. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION, APPLY APPROPRIATE ANTI -OXIDIZATION PAINT. 19. ANY SITE WHERE THE EQUIPMENT (BTS, CABLE BRIDGE, PPC, GENERATOR, ETC.) IS LOCATED WITHIN 6 FEET OF METAL FENCING, THE GROUND RING SHALL BE BONDED TO THE NEAREST FENCE POST USING (3) RUNS OF #2 BARE TINNED COPPER WIRE. TYPE TA TYPE VN TYPE VB TYPE PT TYPE NC TYPE GT TYPE SS TYPE GY CABLE COLOR CODING NOTES: 1. SECTOR ORIENTATION/AZIMUTH WILL VARY FROM REGION AND IS SITE SPECIFIC. REFER TO RF REPORT FOR EACH SITE TO DETERMINE THE ANTENNA LOCATION AND FUNCTION OF EACH TOWER SECTOR FACE. 2. THE ANTENNA SYSTEM CABLES SHALL BE LABELED WITH VINYL TAPE EXCEPT IN LOCATIONS WHERE ENVIRONMENTAL CONDITIONS CAUSE PHYSICAL DAMAGE, THEN PHYSICAL TAGS ARE PREFERRED. 3. THE STANDARD IS BASED ON EIGHT COLORED TAPES - RED, BLUE, GREEN, YELLOW, ORANGE, BROWN, WHITE & VIOLET. THESE TAPES MUST BE 3/4" WIDE & W RESISTANT SUCH AS SCOTCH 35 VINYL ELECTRICAL COLOR CODING TAPE AND SHOULD BE READILY AVAILABLE TO THE ELECTRICIAN OR SUBCONTRACTOR ON SITE. 4. USING COLOR BANDS ON THE CABLES, MARK ALL RF CABLES BY SECTOR AND NUMBER AS SHOWN ON "CABLE MARKING COLOR CONVENTION TABLE". 5. WHEN AN EXISTING COAXIAL LINE THAT IS INTENDED TO BE A SHARED LINE BETWEEN GSM/3G AND IS-136 TDMA IS ENCOUNTERED, THE SUBCONTRACTOR SHALL REMOVE THE EXISTING COLOR CODING SCHEME AND REPLACE IT WITH THE COLOR CODING AND TAGGING STANDARD THAT IS OUTLINED IN THE CURRENT VERSION OF ND-00027. IN THE ABSENCE OF AN EXISTING COLOR CODING TAGGING SCHEME, OR WHEN INSTAWNG PROPOSED COAXIAL CABLES, THIS GUIDELINE SHALL BE IMPLEMENTED AT THAT SITE REGARDLESS OF TECHNOLOGY. 6. ALL COLOR CODE TAPE SHALL BE 3M-35 AND SHALL BE A MINIMUM OR (3) WRAPS OF TAPE AND SHALL BE NEATLY TRIMMED AND SMOOTHED OUT SO AS TO AVOID UNRAVELING. 7. ALL COLOR BANDS INSTALLED AT THE TOP OF TOWER SHALL BE A MINIMUM OF 3" WIDE AND SHALL HAVE A MINIMUM OF 3/4" OF SPACE IN BETWEEN EACH COLOR. 8. ALL COLOR CODES SHALL BE INSTALLED AS TO ALIGN NEATLY WITH ONE ANOTHER FROM SIDE TO SIDE. 9. IF EXISTING CABLES AT THE SITE ALREADY HAVE A COLOR CODING SCHEME AND THEY ARE NOT INTENDED TO BE REUSED OR SHARED WITH THE GSM TECHNOLOGY, THE EXISTING COLOR CODING SCHEME SHALL REMAIN UNTOUCHED. CABLE MARKING TAGS: WHEN USING THE ALTERNATIVE LABELING METHOD, EACH RF CABLE SHALL BE IDENTIFIED WITH A METAL ID TAG MADE OF STAINLESS STEEL OR BRASS. THE TAG SHALL BE 1-1/2" IN DIAMETER WITH 1/4" STAMPED LETTERS AND NUMBERS INDICATION THE SECTOR, ANTENNA POSITION AND CABLE NUMBER. ID MARKING LOCATIONS SHOULD BE AS PER "CABLE MARKING LOCATIONS TABLE". THE TAG SHOULD BE ATTACHED WITH CORROSION PROOF WIRE AROUND THE CABLE AT THE SAME LOCATION AS DEFINED ABOVE. THE TAG SHOULD BE LABELED AS SHOWN ON THE "GSM AND UMTS LINE TAG" DETAIL CABLE MARKING LOCATIONS TABLE NO. LOCATIONS 1 EACH JUMPER SHALL BE COLOR CODED WITH (1) SET OF 3" WIDE BANDS. OBANDS EACH MAIN COAX SHALL BE COLOR CODED WITH (1) SET OF 3" WIDE AT THE TOP JUMPER CONNECTION AND WITH (1) SET OF 3/4" WIDE COLOR BANDS PRIOR TO ENTERING THE BTS OR SHELTER. OCABLE ENTRY PORT ON THE INTERIOR OF SHELTER. O4 ALL BOTTOM JUMPERS SHALL BE COLOR CODED WITH (1) SET OF 3/4" WIDE BANDS ON EACH END OF THE BOTTOM JUMPER. OALL BOTTOM JUMPERS SHALL BE COLOR CODED WITH (1) SET OF 3/4" WIDE BANDS ON EACH END OF THE BOTTOM JUMPER. TYPE W tik TYPE VS TYPE GR TYPE GL CADWELD GROUNDING CONNECTION DETAILS SCALE: N.T.S. TOP OF TOWER PROPOSED PROPOSED / ANTENNA MOUNT ANTENNA AWG SOLID TINNED COPPER WIRE (TYP) PROPOSED SECTOR GROUND BAR STAINLESS STEEL HARDWARE GROUNDING CABLE PROPOSED EQUIPMENT PROPOSED JUMPER ANTENNA & CABLE GROUNDING SCALE: N.T.S. TWO HOLE COPPER COMPRESSION TERMINAL GROUNDING BAR ELEVATION SECTION "A -A" FLAT WASHER (TYP) 1/2"x1 1/2" HEX BOLT (TYP, STAINLESS STEEL) EXPOSED BARE COPPER TO BE KEPT TO ABSOLUTE MINIMUM, NO INSULATION ALLOWED WITHIN THE COMPRESSION TERMINAL (TYP) NOTE* 1. "DOUBLING UP" OR "STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. CTYPICAL GROUND BAR CONNECTION DETAIL SCALE: N.T.S. GROUNDING STRAP FIGURE l O GRADE 1 CO M GROUND WIRE CAD WELD 5/8"0 x 10' LONG COPPER CLAD STEEL GROUND ROD GROUNDING ROD DETAIL SCALE: N.T.S. S/S NUT S/S BELLEVILLE WASHER 1�1 11 • M AII01 'E_MLAT E COPPER BUSS � 1i1 1i1 S/S FWASHER HEAT SHRINK (CLEAR) 1/8" MIN. 1/4" MIN. S/S BOLT (1 OF 2 EOM: S/S FLAT WASHER LABEL HEAT SHRINK (CLEAR) "DO NOT DISCONNECT" TAG ON ALL GROUND BAR INTERCONNECTS 1. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING BELLEVILLES. COAT ALL SURFACES WITH ANTI -OXIDATION COMPOUND BEFORE MATING. 2. FOR GROUND BOND TO STEEL ONLY: INSERT A DRAGON TOOTH WASHER BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH ANTI -OXIDATION COMPOUND. 3. COAT ALL BARRELS WITH ANTI -OXIDATION COMPOUND BEFORE CRIMPING. GENERAL LUG DETAIL SCALE: N.T.S. FIGURE 2 GROUNDING LUG ADJUSTABLE STRAP GROUNDING CLAMP JACKET TRIM AREA FIGURE 3 FIGURE 6 ELECTRICAL TAPE OVER THE PUTTY TAPE PUTTY TAPE 15/16" HEX ROUNDING CLAMP SLOT FOR HODE CLAMP STAINLESS STEEL HODE CLAMP GROUNDING STAP ASSEMBLY FIGURE 4 00r Al PF FIGURE 7 CGROUNDING STRAP WEATHERPROOFING DETAIL SCALE: N.T.S. B+T GRP C ITYSWTCH MOUNTAIN? LTD. MOUNTAIN LTD, WIRELES FA#10142260 Z 0 V 0 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 1 +•,.R., FE5 I0N�:�/�.�: • SE ti el._ i INE:r ,' ,d4,..l1f1111 1lyt 5/ IT IS A VIOLATION OF LAW FORANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. GROUNDING DETAILS SHEET NUMBER: G-2 CASE # 20-08-GCCP-05794 h 132151_NCC019_CD (11).dwg — Sheet:G-3 — User: mspeedie — ANTENNA CABLES MOUNTING PLATE FOR GROUND BAR (TO SUIT) WITH TAMPER RESISTANT FASTENERS (PREFERRED) OR DRILL AND TAP TOWER LEG FOR 1/4-20 STAINLESS STEEL BOLTS (2 REQ) STAND-OFF INSULATORS #2 BARE SOLID TINNED COPPER GROUND WIRE CADWELD CONNECTION TO TOWER 0 TOWER JUMP ICE BRIDGE SECTIONS. UTILIZE #2 GREEN THHN HYPRESS LUGS ON BOTH SIDES WITH DOUBLE BOLT CONNECTIONS (TYP) - GK-GROUND KIT BASE OF TOWER. 1/4"x4"x20" LG "EMC" TAMPER RESISTANT GALVANIZED STEEL BUS BAR PART #EM SGM420-BI-NR (SEE DETAIL) CONDUIT STRAPS TO SUIT NOTE: ALL ICE BRIDGE POSTS. EXTEND CONCRETE TO 6" ABOVE GRADE AND CROWN TOP #2 BARE SOUD TINNED COPPER GROUND WIRE 14 6"0x42" MIN. DEPTH PVC TEST WELL WITH HAND REMOVABLE PVC TEST WELL COVER OR EQUIV. 4"+/— JUMP ICE BRIDGE SECTIONS. UTIUZE #2 GREEN THHN HYPRESS LUGS ON BOTH SIDES WITH DOUBLE BOLT CONNECTIONS (TYP) ANTENNA CABLES NEW ICE BRIDGE -\ JUMP ICE BRIDGE SECTIONS. UTILIZE #2 GREEN THHN HYPRESS LUGS ON BOTH SIDES WITH DOUBLE BOLT CONNECTIONS (TYP) U GALVANIZED STEEL BUS BAR GK-GROUND KIT / EXTERIOR J (2)-#2 BARE SOLID TINNED COPPER GROUND WIRE IN 1" DIA. PVC SCH. 40 CONDUIT (TYP). EXTEND CONDUIT 6" BELOW GRADE. CADWELD GROUND WIRE TO BUS BAR Iii #2 BARE SOLID TINNED COPPER GROUND WIRE tY COAXIAL GROUNDING AT ICE BRIDGE USE VSC-1T-V3C VERTICAL CADWELD MOLD 36" MIN. OR 6" TOP OF CRUSHED STONE 45' EXIT OUT OF BUILDING SLEEVED IN 1" PVC SCH. 40 CONDUIT, 18" BELOW GRADE ALL GROUND LEADS GOING BELOW GRADE NEED SLEEVED CRUSHED GRAVEL FINISHED GRADE 2'0 HOLE DRILLED FOR GROUND RING co SCALE: N.T.S. L TOP OF COMPOUND STONE a5D... i I. .mil,,I/�I..0. �``T`��`�>•}`V``,- ✓e-,\•,,.(, `GEOTEXTILE FABRIC 1? a DIRECT BURIAL CABLE OR CONDUIT (POWER, CONTROL, TELEPHONE, TELEMETERING, ETC) JNSTALLATION 1. THE TAPE SHALL BE LAID DIRECTLY ABOVE THE CABLE OR CONDUIT UNDER RIGID TYPE AND OIL MAT PAVEMENTS, AND DIRECTLY ON TOP OF THE COMPACTED EARTH SUBGRADE IMMEDIATELY BEFORE RESTORING THE PAVEMENT. 2. IN OPEN AREAS, THE TAPE SHALL BE LAID DURING THE BACKFIWNG OPERATION ON SMOOTH, COMPACTED BACKFILL AT A DISTANCE OF 8" BELOW THE SURFACE OF THE AREA. 3. THE ENDS OF THE TAPE SHALL BE LAPPED APPROXIMATELY SIX (6) INCHES. 4. TAPE SHALL BE THE COLOR AS INDICATED AND HAVE THE FOLLOWING MARKINGS: RED CAUTION CAUTION BURIED ELECTRIC UNE BELOW CAUTION ORANGE CAUTION CAUTION BURIED TELEPHONE UNE BELOW CAUTION STANDARD MARKER TAPE DETAIL SCALE: N.T.S. „ ®er75" :®•®®®®®•®®®•®®•® ®o®tmooecoomomom > 000k, `gin . r=. ;;;;;;;;;.;;®;;;;; 20" TOP OF GROUND /%/, COPPER#2 AWG BARE TINNED LID WIRE TEST LOOP CADWELD GROUND RING TO ROD / / #2 AWG BARE TINNED SOLID /\/ COPPER WIRE GROUND RING 4" TO 6"+/— OF LOOSE GRAVEL 5/8"0X10'-0" LG. COPPER CLAD STEEL GROUND ROD GROUND INSPECTION TEST WELL DETAIL SCALE: N.T.S. 4 .469x.719 TYP (41) PL .265 IN HIGH CHARACTER, STAMPING TO READ: "PROPERTY AT&T DO NOT RECYCLE" 0 .469x.719 TYP (41) PL +/- 4 go INCLUDE (2) EXTRA TAMPER RESISTANT IN BAG (AS SHOWN) INSTALL IN SEAL TIGHT OR PVC CONDUIT TO 18" BELOW GRADE VERTICAL POST CONNECTED TO RING TYPICAL FENCE POST FENCE FABRIC VERTICAL CADWELD MOLD (TYP) NOTE: CADWELD ALL LINE FENCE POSTS 70 #2 BARE SOUD TINNED COPPER WIRE TYPICAL FENCE POST GROUNDING SCALE: N.T.S. NOTE: #2 SOUD TINNED GROUND *6" ABOVE PROVIDE & INSTALL 1/4x4x12 ELECTRIC MOTION TINNED COPPER BOTTOM OF METER BOARD FASTEN BUS BAR ON RED SEAL INSULATORS & STAINLESS STEEL WITH UV RATED PLASTIC FASTENER; BRACKET FOR LANDING OF ALL GROUNDS AT UTILITY BOARD. 0 24" CENTERS ELCO GROUND COAT WITH ELECTRIC MOTION ANTI -THEFT COMPOUND. 2" SHOWN INSTALLED WITH HEAD REMOVED (TAMPER RESISTANT) TOWER LEG BUS BAR DETAIL II1'I #2 BST TO BUS BAR -VI 6J = — — — CADWELD (TYP)Thilli 5/8"x10' GROUND ROD 10. 0" #2 BARE SOLID TINNED TO GROUND RING AS SHOWN ON PLAN (Dl1 3/4"x10' GROUND ROD USE GTC-181T CADWELD CONNECTION METER BOARD UTILITY GROUNDING DETAIL SCALE: N.T.S. BOLT TO ANGLE IRON (OR TOWER LEG) TAMPER RESISTANT HARDWARE (SEE ITEM #4) 2 4 02-009-0663-000 (SUB ASSEMBLY) 3/8-16x5/8" TORQUE SHEAR HEAD BOLT IN A STANDARD 4x6 BAG INCLUDES: (2) 3/8-16x5/8" TORQUE SHEAR HEAD BOLT (NON -REMOVABLE) WITH VIBRSEAL; STAINLESS STEEL (303) P/N 02-009-0603-000 (1) STANDARD 4"x6" BAG (P/N 03-009-0209-00) 1 3 02-009-0633-000 3/8-16x5/8" TORQUE SHEAR HEAD BOLT (NON- REMOVABLE) WITH VIBRSEAL; STAINLESS STEEL (303) 2 2 03-009-0118-000 2"x2" INSULATOR; FIBERGLASS 2 1 02-009-0672-000 20' GROUND BAR; STEEL: GALVANIZED 1 REM PART NO. DESCRIPTION REQ si»IC' ° Gimirliaggi warm a con PART /EII SGM420-81-NR SCALE: N.T.S. O #2 SOLID WITH ±10'-0" LONG TAIL AT THIS LOCATION FOR ELECTRIC GROUND CADWELD WIRE TO POSTS #2 STRANDED GREEN COPPER WIRE GATE GROUNDING DETAIL SCALE: N.T.S. B+T GRP CITYSWIT CH MOUNTAIN? LTD. MOUNTAIN LTD, WIRELES FA#10142260 Z 0 O V O 0 0 0 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 ,<;%%%s;R.F-e5 IpN:/... 7 iA A. d�,,l If11111 Ixl) /�� IT IS A VIOLATION OF LAW Foe-MY(PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. GROUNDING DETAILS SHEET NUMBER: G-3 CASE # 20-08-GCCP-05794 E E D 132151_NCC019_CD (11).dwg — She PROPOSED 25' WIDE INGRESS/EGRESS EASEMENT PROPOSED 10' WIDE UTILITIES EASEMENT PROPOSED 14' WIDE / GRAVEL ACCESS ROAD/ / / / / / / / / 0 / / / LANDSCAPE PLAN SCALE: 0' 1/////////////////// %//////////////// 15' 30' 45' TYPE A 40' LANDSCAPE BUFFER WETLAND LIMITS • 0 PROPOSED 50' x 50' FENCED COMPOUND 0 , • 1"=30' 60' PROPOSED 130' x 130' LEASE PARCEL LANDSCAPE DESIGN NOTES: 1. A ROW OF PINUS TAEDA (LOBLOLLY PINE) SHADE TREES A MINIMUM OF EIGHT (8) FEET TALL WITH TWO (2) INCHES IN CALIPER, AND A MAXIMUM OF TWENTY (25) FEET APART; 4 TREES PER 100' OF PERIMETER, SHALL BE PLANTED ADJACENT TO THE PERIMETER OF THE FENCE. 2. AN IRREGULAR ROW OF QUERCUS LYRATA (OVERCUP OAK), A MINUMUM OF FOUR (4) FEET TALL WITH ONE (1) INCH IN CALIPER, MEASURED 6" ABOVE GRADE WHEN PLANTED; 10 TREES PER 100' OF PERIMETER, SHALL BE PLANTED EVENLY WITHIN THE LANDSCAPE BUFFER AREA. 3. AUCUBA JAPONICA (JAPANESE AUCUBA) AT LEAST EIGHTEEN (18) INCHES HIGH AT PLANTING CAPABLE OF GROWING TO AT LEAST THIRTY—SIX (36) INCHES IN HEIGHT WITHIN EIGHTEEN (18) MONTHS SHALL BE PLANTED IN FRONT OF THE TREE LINE REFERENCED ABOVE. 4. TOWER LANDSCAPING COMPLIES WITH GUILFORD COUNTY ORDINANCE LANDSCAPE REQUIREMENTS. 5. SITE ADDRESS SHALL BE POSTED AT TIME OF INSPECTION. 6. SEE ADDITIONAL LANDSCAPING/IRRIGATION NOTES ON SHT L-2. PLANT MATERIAL SCHEDULE OTY BOTANICAL NAME COMMON NAME 13 PINUS TAEDA LOBLOLLY PINE 26 OUERCUS LYRATA OVERCUP OAK 81 AUCUBA JAPONICA JAPANESE AUCUBA LEGEND 0 PINUS TAEDA (LOBLOLLY PINE) QUERCUS LYRATA (BLACKJACK OAK) AUCUBA JAPONICA (JAPANESE AUCUBA) THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING ON THE WORK CONTAINED WITHIN THIS DESIGN PACKAGE. DISCREPANCIES AND OMISSIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. =IF B+T GRP CITYSWIT CH AllEv MOUNTAIN? LTD. MOUNTAIN LTD, WIRELES G1 1 U U z FA#10142260 E. Z p O V O C7 PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 Pt,Y1' �`•111• .,`'%%% CAR �,, l'‹Z..: F�5 IpN�:(diA 7 SE 40, INS IT IS A VIOLATION OF LAW FORANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. LANDSCAPE & IRRIGATION PLAN SHEET NUMBER: L-1 CASE # 20-08-GCCP-05794 N 0 N E 0, 3 132151_NCC019_CD LANDSCAPE DESIGN NOTES: 1. A ROW OF PINUS TAEDA (LOBLOLLY PINE) SHADE TREES A MINIMUM OF EIGHT (8) FEET TALL WITH TWO (2) INCHES IN CALIPER, AND A MAXIMUM OF TWENTY (25) FEET APART; 4 TREES PER 100' OF PERIMETER, SHALL BE PLANTED ADJACENT TO THE PERIMETER OF THE FENCE. 2. AN IRREGULAR ROW OF QUERCUS LYRATA (OVERCUP OAK), A MINUMUM OF FOUR (4) FEET TALL WITH ONE (1) INCH IN CALIPER, MEASURED 6" ABOVE GRADE WHEN PLANTED; 10 TREES PER 100' OF PERIMETER, SHALL BE PLANTED EVENLY WITHIN THE LANDSCAPE BUFFER AREA. 3. AUCUBA JAPONICA (JAPANESE AUCUBA) AT LEAST EIGHTEEN (18) INCHES HIGH AT PLANTING CAPABLE OF GROWING TO AT LEAST THIRTY-SIX (36) INCHES IN HEIGHT WITHIN EIGHTEEN (18) MONTHS SHALL BE PLANTED IN FRONT OF THE TREE LINE REFERENCED ABOVE. 4. TOWER LANDSCAPING COMPLIES WITH GUILFORD COUNTY ORDINANCE LANDSCAPE REQUIREMENTS. 5. SITE ADDRESS SHALL BE POSTED AT TIME OF INSPECTION. 6. SEE ADDITIONAL LANDSCAPING/IRRIGATION NOTES. 2 X 2 PT. WD. STAKE 6" BAILED PINESTRAW rnaalllill lllll lllllllllllllllul l Asl RUBBER HOSE TIED TO TREE & STAKE WITH WIRE GRADE AT WHICH TREE GREW AT NURSERY BACKFILL WITH PLANTING SOIL AND TOP W/ PINE STRAW MULCH REMOVE TOP 1/3 OF BURLAP TAMP TO PREVENT SETTLEMENT TREE PLANTING DETAIL NOT TO SCALE IRRIGATION NOTES: 1. THE CONTRACTOR MUST MAINTAIN THE LANDSCAPING FOR 1 YEAR FROM THE DATE OF CONSTRUCTION COMPLETION. THIS INCLUDES BUT IS NOT LIMITED TO WATERING AND INSURING THAT THE LANDSCAPING DO NOT DIE. IF ANY OF THE LANDSCAPING DIES WITHIN THE 1 YEAR TIME FRAME, THE CONTRACTOR MUST REPLACE IT WITH EQUIVALENT LANDSCAPING WITHIN 30 DAYS OF OBSERVING THE DEAD PLANT MATERIAL. CONTRACTOR SHALL UTILIZE A WATER TRUCK TO PROVIDE IRRIGATION. LANDSCAPING WILL BE WATERED A MINIMUM OF TWICE WEEKLY FOR 3-6 MONTHS UNTIL FULLY ESTABLISHED. EACH TREE TO RECEIVE 3 TO 6 GALLONS OF WATER EACH TIME IT IS IRRIGATED AND SHRUBS TO RECEIVE TO 2 GALLONS PER IRRIGATION. ALL WATERING TO BE IN ACCORDANCE WITH NCSU Ag EXTENSION RECOMMENDATIONS. AFTER THIS 1 YEAR ESTABLISHMENT PERIOD, THE LANDOWNER OF RECORD SHALL BE RESPONSIBLE FOR THE PERPETUAL MAINTENANCE OF THE LANDSCAPING. 2. LEASE OWNER SHALL BE RESPONSIBLE FOR ALL IRRIGATION MAINTENANCE THROUGH THE LIFE OF THE PROJECT. 3. SEE ADDITIONAL LANDSCAPING/IRRIGATION NOTES BELOW. ADDITIONAL LANDSCAPING / IRRIGATION NOTES: 1. ALL PLANT MATERIALS SHALL BE IN ACCORDANCE WITH GUILFORD COUNTY RECOMMENDED PLANT LIST FOR MINIMUM LANDSCAPE BUFFER REQUIREMENTS. 2. SIZES SPECIFIED IN THE PLANT LIST ARE MINIMUM SIZES TO WHICH THE PLANTS ARE TO BE INSTALLED. TRUNK CALIPER IS MEASURED SIX INCHES ABOVE THE GROUND ON TREES. 3. ALL LANDSCAPING SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE GUILFORD COUNTY ORDINANCE LANDSCAPE REQUIREMENTS AND IN ACCORDANCE WITH CURRENT INDUSTRY STANDARDS IN A NEAT, HEALTHY, AND WEED FREE CONDITION. 4. IT IS THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL PLANT BED AREAS HAVE PROPER DRAINAGE FOR OPTIMUM GROWTH OF LANDSCAPE MATERIAL BEFORE INSTALLATION BEGINS. 5. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES. PLANT MATERIAL IS TO BE LOCATED SUCH THAT IT WILL NOT INTERFERE WITH ANY UNDERGROUND OR OVERHEAD UTILITIES. 6. ALL PLANT BEDS AND TREE RINGS SHALL BE TREATED WITH A PRE -EMERGENT HERBICIDE AND THEN TOP -DRESSED WITH 3" DEEP PONE CARK MULCH. ALL NEW TREES SHALL HAVE A TREE RING WITH A MINIMUM 24" RADIUS. ALL NEW TREES AND PALMS SHALL BE STAKED. 7. THE CONTRACTOR MUST MAINTAIN THE LANDSCAPING FOR 1 YEAR FROM THE DATE OF CONSTRUCTION COMPLETION. THIS INCLUDES BUT IS NOT LIMITED TO WATERING AND INSURING THAT THE LANDSCAPING DO NOT DIE. IF ANY OF THE LANDSCAPING DIES WITHIN THE 1 YEAR TIME FRAME, THE CONTRACTOR MUST REPLACE IT WITH EQUIVALENT LANDSCAPING WITHIN 30 DAYS OF OBSERVING THE DEAD PLANT MATERIAL. LANDSCAPING WILL BE WATERED A MINIMUM OF TWICE WEEKLY FOR 3-6 MONTHS UNTIL FULLY ESTABLISHED. EACH TREE TO RECEIVE 3 TO 6 GALLONS OF WATER EACH TIME IT IS IRRIGATED AND SHRUBS TO RECEIVE 1 TO 2 GALLONS PER IRRIGATION. ALL WATERING TO BE IN ACCORDANCE WITH NCSU Ag EXTENSION RECOMMENDATIONS. AFTER THIS 1 YEAR ESTABLISHMENT PERIOD, THE LANDOWNER OF RECORD SHALL BE RESPONSIBLE FOR THE PERPETUAL MAINTENANCE OF THE LANDSCAPING. 8. CONTRACTOR MUST CONFIRM LANDSCAPE REQUIREMENTS AND SPECIFICATIONS WITH LOCAL JURISDICTION. 9. IF EXISTING TREES REMAIN, LOCATION/SPACING OF NEW TREES MAY BE MODIFIED TO AVOID CONFLICT. 10. ALL REPLACEMENT TREES SHALL BE A MINIMUM OF 3' FEET FROM A PROPERTY LINE AND 6' FEE FROM ANY UTILITIES (ABOVE OR BELOW GROUND). ALL TREES PLANTED AND PRUNED MUST ADHERE TO THE ANSI A300 STANDARDS AND MUST HAVE ADEQUATE ROOM, WHEN PLANTED, TO MATURE FREELY. 11. CONTRACTOR SHALL REMOVE ALL NUISANCE, EXOTIC PLANT MATERIAL. REMOVAL OF NUISANCE, EXOTIC PLANT SPECIES THAT BECOME REESTABLISHED WITHIN COMMON, AND OPEN SPACES, SHALL BE CONTINUED FOR THE LIFE OF THE PROJECT. 12. IRRIGATION HAS BEEN DESIGNED IN ACCORDANCE WITH GUILFORD COUNTY DESIGN GUIDELINES, SECTIONS 8 AND 9. INSTALLATION SHALL CONFORM WITH SECTIONS 8-9 OF DESIGN GUIDELINES. 13. THE IRRIGATION DESIGN IN THIS PLAN IS A TEMPORARY SYSTEM. 14. SITE ADDRESS SHALL BE POSTED AT TIME OF INSPECTION. 15. ALL NEW LANDSCAPING MUST BE MAINTAINED FOR THE LIFE OF THE USE. THIS INCLUDES BUT IS NOT LIMITED TO WATERING AND INSURING THAT THE LANDSCAPING DO NOT DIE. IF ANY OF THE LANDSCAPING DIES WITHIN THE 1 YEAR TIME FRAME, THE CONTRACTOR MUST REPLACE IT WITH EQUIVALENT LANDSCAPING WITHIN 30 DAYS OF OBSERVING THE DEAD PLANT MATERIAL. LANDSCAPING WILL BE WATERED A MINIMUM OF TWICE WEEKLY FOR 3-6 MONTHS UNTIL FULLY ESTABLISHED. BEYOND 3 MONTHS, EACH TREE TO RECEIVE 3 TO 6 GALLONS OF WATER EACH TIME IT IS IRRIGATED AND SHRUBS TO RECEIVE 1,4 TO 2 GALLONS PER IRRIGATION. ALL WATERING TO BE IN ACCORDANCE WITH NCSU Ag EXTENSION RECOMMENDATIONS. THIS IRRIGATION SCHEDULE SHALL CONTINUE THROUGH THE LIFE OF THE PROJECT AND SHALL BE REEVALUATED ANNUALLY TO INSURE PROPER VEGETATION HEALTH. THE LEASE OWNER OF RECORD SHALL BE RESPONSIBLE FOR THE PERPETUAL MAINTENANCE OF THE LANDSCAPING. -p B+T GRP C ITYSWIT C H MOUNTAIN LTD, WIRELES G1 1 U U z FA#10142260 4226-ZZ1 CAMP BURTON ROAD McLEANSVILLE, NC 27301 PROPOSED 220' SELF SUPPORT TOWER PROJECT NO: 132151 CHECKED BY: GEM ISSUED FOR: REV DATE DRWN DESCRIPTION 9 06/04/21 MAS CONSTRUCTION 10 10/22/21 MAS CONSTRUCTION 11 10/25/21 MAS CONSTRUCTION B&T ENGINEERING, INC. C-4171 a Q � IT IS A VIOIATON OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. LANDSCAPE & IRRIGATION PLAN SHEET NUMBER: L-2 CASE # 20-08-GCCP-05794